ECW-GF, ECW-GF-DP DIGITAL ELECTRONIC CONTROLLERS AND REMOTE DISPLAY PANEL PRODUCT OVERVIEW

Similar documents
THERMAL MANAGEMENT SOLUTIONS

THERMAL MANAGEMENT SOLUTIONS

C SINGLE-POINT HEAT-TRACING CONTROL SYSTEM PRODUCT OVERVIEW

910 Series Single-point heat-tracing control system

Dual-point heat-tracing control system

JBS-100-EC Electronic controller replacement kit for JBS-100-ECP-A and JBS-100-ECW-A Installation Instructions

C910 Series. Single-point heat-tracing control system

ACS-30 MULTIPOINT COMMERCIAL HEAT-TRACING SYSTEM PRODUCT OVERVIEW. ACS-30 System

C SINGLE-POINT HEAT-TRACING CONTROL SYSTEM. product overview

JBS-100-ECP-A COMBINATION POWER CONNECTION BOX AND DIGITAL ELECTRONIC CONTROLLER INSTALLATION INSTRUCTIONS

CSI Master Format 2004 Guide Specification for: Freezer Frost Heave Prevention (Mineral Insulated)

SMPG3 SNOW MELTING AND DE-ICING POWER DISTRIBUTION AND CONTROL PANEL. For three-phase heating cables PRODUCT OVERVIEW

CSI Master Format 2004 Guide Specification for: Flow Maintenance of Above Ground Greasy Waste Disposal Lines

CSI Master Format 2004 Guide Specification for: Flow Maintenance of Aboveground Fuel Oil Lines

HTC-915-CONT. Heat-Trace Control system

NGC-40 Advanced Heat-Tracing Control System

CSI Master Format 2012 Guide Specification for: Hot Water Temperature Maintenance (HWAT) Systems

920 Series. A dry contact relay is provided for alarm annunciation back to a distributed control system (DCS).

CSI Master Format 2004 Guide Specification for: Snow Melting (Mineral Insulated)

Pipe Freeze Protection Control SCFP-CO-F130 Installation and Operation Manual

HOT WATER TEMPERATURE MAINTENANCE HWAT SYSTEM

Freezer Frost Heave Prevention

NGC-UIT2 MODBUS PROTOCOL INTERFACE MAPPING FOR NGC-30 SYSTEMS. Firmware versions up to V2.0.X

NGC-40 PANEL MOUNTED ADVANCED MODULAR HEAT-TRACING CONTROL SYSTEM HTC HTC3

For Raychem ACS-30 Controls Systems

Dual Point General Purpose Heat Trace Control TRACON MODEL GPT 230 Installation and Operation Manual

ACCS-30. Multipoint commercial heat-tracing control system

NGC-UIT-ORD User interface terminal for Raychem NGC systems Installation Instructions

TYPE CM-2201 NELSON SINGLE POINT CIRCUIT MANAGEMENT SYSTEM

Single Point Freeze Protection Heat Trace Control TRACON MODEL FPT 130 Installation and Operation Manual

DESIGN GUIDELINES. THERMAL building SOLUTIONS

FIRE SPRINKLER SYSTEM FREEZE PROTECTION XL-TRACE SYSTEM

XL-Trace System. Installation and Operation manual for pipe freeze protection and flow maintenance

MODEL GPT-130 SINGLE POINT HEAT TRACE CONTROL THERMOSTAT

TTSIM-2 TRACETEK SENSOR INTERFACE MODULE WITH LCD AND RELAY INSTALLATION/OPERATION INSTRUCTIONS

THERMAL BUILDING SOLUTIONS EN-TraceTekTTSIM1A-IM-H /16

NGC-40-IO Control and monitoring modules for use with the Raychem NGC-40 system Installation Instructions

Dual Point General Purpose Heat Trace Control TRACON MODEL GPT 230 Installation and Operation Manual

ROOF AND GUTTER DE-ICING ICESTOP SYSTEM

SMPG1 SNOW MELTING AND DE-ICING POWER DISTRIBUTION AND CONTROL PANEL FOR SINGLE-PHASE HEATING CABLES PRODUCT OVERVIEW

SAFETY INFORMATION AND WARNINGS

ACS-30-EU-EMDR- 10-MOD

MODEL FPT-130 SINGLE POINT FREEZE PROTECTION HEAT TRACE CONTROL

XL-Trace System Application and Design Guide

NGC-UIT2-ORD-R Remote User Interface Terminal for Raychem NGC Systems Installation Instructions

FTC-HST WARNING: CAUTION:

RAYCHEM NGC-30 COMPONENTS

ROOF ICE MELT (RIM) SYSTEM

FreezGard. Self-regulating crankcase heater. Product Overview

Design Guide Design Notes Design Examples Technical Data Sheets Expanded Capabilities Specifications Warranty

HWAT -ECO. Installation and Operation Manual. Electronic controller for hot water temperature maintenance systems

DESCRIPTION. 42 mm. 125 mm

Pipe Freeze Protection. Flow Maintenance. Introduction. XL-Trace System

TraceNet ECM Series Control System

ACS-30-EU-VIA-DU-20-MOD

IceStop System INSTALLATION AND OPERATION MANUAL FOR ROOF AND GUTTER DE-ICING SYSTEMS

HHS-WWH HOPPER HEATING SYSTEM WRAP-WOUND HEATER INSTALLATION INSTRUCTIONS DESCRIPTION. HHS-WWH PRODUCT SPECIfICATIONS

NGC-40 PANEL MOUNTED ADVANCED MODULAR HEAT-TRACING CONTROL SYSTEM HTC HTC3 PRODUCT OVERVIEW

C Heat Trace Controller

Ramsey Motion Monitoring Systems

Roof and Gutter De-Icing

Cimco Series 21. Series 21 - Specifications INDEX. Description. Operational Specification 2

TOUCH 1500 User Interface Terminal for Raychem NGC Systems Installation Instructions

Longline Heating. Contents. Introduction

MODEL SST 2 40 FREEZE PROTECTION THERMOSTAT MODEL SST FIXED SET POINT THERMOSTAT. Installation and Operation Manual

PACSystems* RX3i. Thermocouple Input Module, 12 Channels, IC695ALG412. GFK-2578B October 2011

COMMERCIAL HEAT TRACING PRODUCTS AND SERVICES

Installation Instructions DTC-24 SNOw MELTING &

Installation and Operation Manual

Module Features are-configurable, no module jumpers to set

JB-RTD-STAND RTD PIPE STAND FOR COMBINATION POWER CONNECTION BOX AND ELECTRONIC CONTROLLER INSTALLATION INSTRUCTIONS

Sensor Interface Module Installation/Operation Instructions

Hot Water Temperature Maintenance. HWAT System. Product Selection and Design Guide

COMMERCIAL & RESIDENTIAL MARKETS U.S. ELECTRICAL

Fax (724) Main St.; P. O. Box 248 West Middlesex, PA IMPORTANT NOTICE

NELSON CM HEAT TRACE CONTROLLER Installation and Operating Instructions

Motogard. Over Temperature Protection System. Installation Instructions

Skin-Effect Heat-Tracing System (STS)

ADDITIONAL INFORMATION

DTC-24 SNOW MELTING & ROOF DE-ICING CONTROLS

Dual Input ph/orp Analyzer

ITC 2000 HEATING CONTROL CABINET. Installation & Operation Manual

Ramsey Series Motion Monitoring Systems Accurate Sensing of Speed Conditions on Rotating Shafts and Machinery

Dual Input Toroidal Analyzer

TCA-9102 Series Surface Mount Temperature Controllers with High and Low Alarm

COMMERCIAL & RESIDENTIAL SELF-REGULATING HEATING PRODUCTS APPLICATION AND DESIGN GUIDE EUROPE, MIDDLE EAST, AFRICA

CLEANROOM MONITOR CR3A Network - Installation Instructions

Thermo Scientific Ramsey TM Series Sensing Speed Conditions on Rotating Shafts and Machinery

tcm100, tcm101 Series Temperature Control Modules and PTS100, PTS100/3 Pipe Temperature Sensors Operations Manual

NGC-20-C-E and NGC-20-CL-E

T60xDFH-4 and T60xDFH-4+PIR Series Thermostat Controllers with Dehumidification and Occupancy Sensing Capability

T7984 A,B,C Electronic Modulating Control Thermostats

PANEL MOUNTED ELECTRONIC MULTI-CIRCUIT HEAT-TRACING CONTROL, MONITORING AND POWER DISTRIBUTION SYSTEM mm. 100 mm

SPECIFICATION GUIDELINE FROST PROTECTION FOR PIPES. Tender Specification. Engineering Specification for Pipe Frost Protection. Contents.

TTSIM-1A. TraceTek Sensor Interface Module with Relay. Installation/Operation Instructions. Installation Items (not supplied) Tools Required.

Pump-Down Controller MODEL 4052

ACT2-CS Convenience Store Controller

Dual Input ph/conductivity Analyzer

PROJECT MANAGEMENT Transmittal No 17D

DIGITAL METERS Large Display Temperature Meters Instruction Manual

Transcription:

DIGITAL ELECTRONIC CONTROLLERS AND REMOTE DISPLAY PANEL ECW-GF with FTC-PSK pipe stand and power connection kit ECW-GF using RayClic power connection kit ECW-GF-DP remote display panel available only with ECW-GF ECW-GF-DP PRODUCT OVERVIEW The Raychem ECW-GF electronic controller provides accurate temperature control with integrated 30-mA ground-fault protection. The ECW-GF is ideal for pipe freeze protection, flow maintenance, freezer frost heave, floor heating and snow melting applications. The ECW-GF is housed in a NEMA 4X enclosure designed to be wall mounted or installed on a pipe with the optional Raychem FTC-PSK pipe stand kit. The controller includes a window and a digital display that shows the measured temperature, set point temperature and alarm conditions (temperature sensor failure, high or low temperature and ground-fault) if detected. Alarm conditions can be indicated via a Form C dry contact connected to a building management system. Status LEDs indicate whether the digital display is showing the set point or actual temperature or if the controller is in an alarm state. The ECW-GF can be programmed to maintain temperatures up to 200 F (93 C), at voltages from 100 to 277 V, and is capable of switching current up to 30 amperes. Programming the set point temperature, deadband, and the high and low alarm thresholds on the controllers is accomplished using the built-in digital display and push buttons. A 9-V battery connector is supplied to allow programming the controller before the heating cable circuit power is provided. ECW-GF using a separate junction box An optional remote display panel, the Raychem ECW-GF-DP, is available. This remote display provides remote alarm indication and ground-fault test and reset capability. The ECW-GF-DP can be installed indoors in a standard duplex box located up to 328 ft (100 m) from the controller. The ECW-GF is supplied with a 25-foot thermistor for line, slab or ambient sensing temperature control. 1 / 5

ECW-GF CONTROLLER Display Menu Battery connection Remote display panel (ECW-GF-DP only) Thermistor terminals Alarm terminals ECW-GF without wire cover Wire cover Lid Wall mounting holes (typical 4) Actual temp LED Set point temp LED Next, Up, Down Heating cable power terminals Ground terminal Incoming power terminals MENU Hold 3 Seconds Battery Connector Menu Settings: Units ( F or C) Set Point Dead Band High Temp Alarm Low Temp Alarm Remote GF Panel ECW-GF Digital Controller with Ground-Fault Protection TEMPERATURE Next Hold for GF TEST Up Down GF Reset ACTUAL SETPOINT Display: Alarms and Status Ground-fault test mode Ground-fault circuit failure Ground-fault cable fault Shorted or open sensor Remote panel comm failure High temp alarm Low temp alarm WARNING Shock Hazard Do not remove cover while energized Ne pas enlever le couvert tant que le régulateur est sous tension 6.3 in (160 mm) Temperature ECW-GF Digital electronic controller with equipment ground-fault protection Type 4X Input: 100-277 Vac, 50/60 Hz, 30 A Output: 100-277 Vac, 30 A 80BJ Maximum Ambient: 140 F (60 C) Enclosed Energy For maintaining temperatures up to 200 F (93 C) Management Equipment in nonhazardous locations. Equipment Ground-Fault Protection: 30 ma Use only with Raychem, XL-Trace, RaySol and IceStop heating cables and MI heating cables. Actual Setpoint 2013 Pentair Thermal Management LLC WWW.PENTAIRTHERMAL.COM H58407 07/13 Stand-offs Note: Next button is used for ground-fault test. Down button is used for ground-fault reset. 6.3 in (160 mm) GENERAL Approvals Nonhazardous locations Supply voltage 100 277 Vac ±10% 50 60 Hz Common supply for controller and heat tracing circuit ENCLOSURE Protection Material Entries Relative humidity Ambient installation and usage temperature NEMA 4X Fiberglass reinforced polyester plastic 1 x 3/4 in (19 mm) conduit entries for power 1 x 1 in (25 mm) conduit entry for heating cable 1 x 1/2 in (13 mm) conduit entry for RTD sensor 0% to 90%, noncondensing 40 F to 140 F ( 40 C to 60 C) CONTROL Relay type Control range Deadband Accuracy Double-pole, mechanical 32 F to 200 F (0 C to 93 C) Adjustable 2 F to 10 F (2 C to 6 C) ±3 F (1.7 C) of set point INPUT POWER Voltage Current 277 Vac nominal, 50/60 Hz maximum 30 A maximum MONITORING AND ALARM OUTPUT Temperature RTD failure Alarm relay Low alarm range: 20 F ( 6 C) to set point minus deadband, or OFF High alarm range: Set point plus (Deadband +5 F (3 C)) to 230 F, or OFF Shorted or open temperature sensor Form C: 2 A at 277 Vac, 2 A at 48 Vdc 2 / 5

TEMPERATURE SENSOR (INCLUDED) Input type Thermistor 10K ohm @25C Type J GROUND-FAULT Ground-fault protection Ground fault trip reset Ground-fault test 30 ma fixed Reset button, manual Manual ground-fault circuitry test; automatic hourly circuitry test PROGRAMMING AND SETTING Method Units F or C Digital display LEDs Memory Stored parameters Alarm conditions Programmable at controller Push buttons on front panel Four numeric display digits for parameter and error/alarm indication Indicate actual and set point from display and alarm state Nonvolatile, restored after power loss Parameters can be programmed without power supply (external battery) and parameters are stored in nonvolatile memory. Low/high temperature and thermistor failure (open or shorted) Ground-fault trip, ground-fault circuit failure and loss of power. CONNECTION TERMINALS Power supply input Heating cable output Ground Thermistor Alarm Remote display panel ECW-GF-DP REMOTE PANEL (FOR ECW-GF CONTROLLER ONLY) 1.760 in. (44.7 mm) Power Ground-Fault Reset Ground-Fault Test ECW-GF-DP Blinking = Communication error Blinking = Ground-fault trip or circuitry failure Blinking = Ground-faul test pass Blinking alternately red and amber = Other alarm; check ECW-GF 4.110 in. (104.4 mm) 3.806 in. (96.7 mm) 3.275 in. (83.2 mm) 3 / 5

GENERAL Approvals Nonhazardous locations Environment Ambient operating temperature Humidity Indoors, dry area 32 F to 122 F (0 C to 50 C) 90% noncondensing FEATURES LED Buttons Power Connection 3 LEDs 1 green, 1 red, 1 amber 2: Ground-fault reset, Ground-fault test Power provided from ECW-GF controller 12 Vdc @ 100 ma 8 position terminal block 8 conductor 22 AWG shielded cable Alpha - Cat No. 1298C or equivalent 328 ft (100 m) maximum ORDERING DETAILS Description Catalog number Part number Weight/lbs Wall mounted digital electronic controller with ground fault ECW-GF P000000925 4.0 Remote display panel for ECW-GF ECW-GF-DP P000000926 0.3 Pipe mounting kit with power connection and end seal FTC-PSK P000000927 0.2 4 / 5

WWW.PENTAIRTHERMAL.COM NORTH AMERICA Tel: +1.800.545.6258 Fax: +1.800.527.5703 Tel: +1.650.216.1526 Fax: +1.650.474.7711 thermal.info@pentair.com Pentair is owned by Pentair or its global affiliates. All other trademarks are the property of their respective owners. Pentair reserves the right to change specifications without prior notice. 2004 2017 Pentair. 5 / 5