CHEMICAL ENGINEERING TRANSACTIONS

Similar documents
Application of the New Italian Fire Safety Code (D.M. 3 agosto 2015) to Case Study 3 Mall. Enrico Danzi Luca Fiorentini Luca Marmo Vincenzo Puccia

POLITECNICO DI TORINO Repository ISTITUZIONALE

Pushing Process Limits Without Compromising Safety

Evaluation of Sorbents at Elevated Temperatures for Downhole Application

Fire protection of emergency electrical devices: effect on the level of risk a case study of a rail tunnel

Fire Investigation in Italian Waste Treatment Plant: lessons learned and future development

Shortcut Model for Predicting Refrigeration Cycle Performance

Evaluation on Combustion Characteristics of Finishing Materials for Exterior Walls

AGENDA INTRODUCTION CELLS AND COMPONENTS PV PERFORMANCE PV APPLICATIONS CODES AND STANDARDS EMERGENCY RESPONSE

Sprinklers Modeling for Tunnel Road Fire Fighting

RISKTOPICS. Photovoltaic systems

First Revision No. 1-NFPA [ Section No ] Submitter Information Verification. Committee Statement 4/15/ :08 AM

Considerations in the Design of Smoke Management Systems for Atriums

Technical Information

Technical Expert to develop grid connection guidelines and standards for the Kingdom of Bahrain

Modeling a real backdraft incident fire

ISO/TR TECHNICAL REPORT. Fire-safety engineering Technical information on methods for evaluating behaviour and movement of people

Fire Risks and Safety Standards

NFPA 70E Edition Update

A Study on Improvement of Fire Protection Systems based on Failure Characteristics accodrding to Yearly Variation in Old Commercial Buildings

Identification of the Most Effective Heat Exchanger for Waste Heat Recovery

FAÇADE FIRE TESTS Towards a new European standard method

Rooftop Photovoltaic (PV) Systems Examining the Risks and Researching the Options

Prevention. Education

An Overview of Extinguishing Systems for Computer Equipment

REQUIREMENTS FOR THE ESTABLISHMENT OF PEST FREE PLACES OF PRODUCTION AND PEST FREE PRODUCTION SITES

COMBUSTIBLE DUST HAZARD RECOGNITION

Temperature Control for

Session Four Functional safety: the next edition of IEC Mirek Generowicz Engineering Manager, I&E Systems Pty Ltd

VDE-QT-PV001:2012/01

Roof Coatings Manufacturers Association October 18, 2012

NUMERICAL SIMULATION OF FIRE SPREAD IN TERMINAL 2 OF BELGRADE AIRPORT. PO Box 522, Belgrade, Serbia and Montenegro

Table EXIT ACCESS TRAVEL DISTANCE a OCCUPANCY SYSTEM SYSTEM. A, E, F-1, I-1, M, b,d R, S-1. B c. F-2, S-2, U c

Certification of Thermographers

1. COOL ROOFS. What is a Cool Roof

6/9/ :58 PM. First Revision No. 1-NFPA [ Section No ] Submitter Information Verification. Committee Statement

PV Systems and Fire safety in Germany

PRELIMINARY ANALYSIS OF THE NUMBER OF OCCUPANTS, FIRE GROWTH, DETECTION TIMES AND PRE-MOVEMENT TIMES FOR PROBABILISTIC RISK ASSESSMENT

Process Safety - Market Requirements. V.P.Raman Mott MacDonald Pvt. Ltd.

VeriSafe Absence of Voltage Tester The safe way to verify the absence of voltage

DOMESTIC SMOKE ALARMS AND SPRINKLERS. Introduction. Materials and methods. Frank SWANN 1. Legislative impact. Review article

The safe way to verify the absence of voltage.

1/8/ :02 AM. Public Input No. 2-NFPA [ Section No ] Statement of Problem and Substantiation for Public Input

Conducting a NFPA 652 Dust Hazard Analysis (DHA): Practical Tips & Approaches

Y. ORMIERES. Fire risk analysis method for nuclear installations

MEDIUM-DENSITY HOUSING # 7. Fire safety

Quantitative Evaluation of the Safety Barriers to Prevent Fired Domino Effect

PREVIEW COPY. Table of Contents. Annexes and Supplemental Materials Lesson One Article 90: Introduction and Purpose... 3

ASSESSMENT OF FIRE BEHAVIOUR OF TIMBER PARTITION MATERIALS WITH A ROOM CALORIMETER

Are we using the wrong design fires for tall building fire strategies, in light of recent full height fires?

COMPENSATORY EFFECTY OF FIXED FIRE FIGHTING SYSTEMS IN TUNNELS

( )

Functional Safety: the Next Edition of IEC 61511

Fire protection documentation. CFPA-E Guideline No 13:2015 F

VENTILATIVE COOLING CONTROL STRATEGIES APPLIED TO PASSIVE HOUSE IN ORDER TO AVOID INDOOR OVERHEATING

Fire safety engineering applied to high-rise building facades

POSITION PAPER ON WATER MIST FOR FIRE FIGHTING APPLICATIONS

Development of standards for MV Switchgear for Arc Flash protection. ABB Group May 20, 2013 Slide 1

Copy of article submitted to Fire Safety Engineering for publication January/February 2009

To: All SAAS Accredited Certification Bodies Subject: Clarification to Emergency and Health & Safety Requirements in the SA8000 Standard

Guide to Compliance with the Electrical Workplace Safety Standards in the United States

This document is a preview generated by EVS

Fire Dynamics Simulation and Evacuation for a Large Shopping Center (Mall), Part II, Evacuation Scenarios

Guide To Troubleshooting INEFFICIENT COOLING FANS

Current Research at University of Naples

Passive fire protection. 6 Passive fire protection. 6.1 Fire compartmentation. Passive fire protection

Development of a European approach to assess the fire performance of facades

AVOID CATASTROPHIC SITUATIONS: EXPERT FIRE AND GAS CONSULTANCY OPTIMIZES SAFETY

Fire in an archive warehouse January 28 th 2002 Roye [Somme] France

Development of Seismic-induced Fire Risk Assessment Method for a Building

SELF PRESERVATION SOCIETY By Jim Creak

FUNCTIONAL SAFETY IN FIRE PROTECTION SYSTEM E-BOOK

Fire outbreak inside a warehouse 5 December 2013 Crépy-En-Valois (Oise) France

Early Warning Fire Detection Engineering

Federal Law of the Russian Federation of December 27, 2009 N 347-FZ "Technical regulation on safety of low-voltage equipment" Part I

Smoldering Propagation Characteristics of Flexible Polyurethane Foam under Different Air Flow Rates

CHOOSING A FIRE VENTILATION STRATEGY FOR AN UNDERGROUND METRO STATION

AVOID CATASTROPHIC SITUATIONS: EXPERT FIRE AND GAS CONSULTANCY OPTIMIZES SAFETY

Protecting Facilities Against Explosions. Since 1956

Fixed fire protection solutions

20 International Conference of The Coastal Society THE ROLE OF PLANNED UNIT DEVELOPMENTS IN ENVIRONMENTAL MANAGEMENT IN THE COASTAL ZONE

TECHNICAL SPECIFICATION

Prerequisite/Co-requisite: Pass the reading and writing portions of COMPASS or other accepted testing instrument.

Fire Risk Assessment and Computer Simulation of Fire Scenario in Underground Mines

High-expansion foam plant UNI EN 13565

SIGNALISATION AND VISUAL GUIDE INTERACTIVE SYSTEM for EVACUATION ROUTES in TUNNELS and CONFINED AREAS

Road tunnel safety rules in Italy: the tunnel country

Is your current safety system compliant to today's safety standard?

COSTCO, SAN FRANCISCO A PRESCRIPTIVE AND PERFORMANCE BASED ANALYSIS OF FIRE PROTECTION SYSTEMS AND DESIGN

HYDROCARBONENGINEERING June June 2015

Study of Numerical Analysis on Smoke Exhaust Performance of Portable Smoke Exhaust Fan

SUSTAINABLE CONSERVATION SYSTEMS FOR PRESERVATION OF MONUMENTS, SITES IN THEIR SETTINGS

Fire Engineering in the UK

Saving lives with coatings

Development of Induction Heating Device for Corner of Bloom in Continuous Casting machine

ELECTRICAL FIRE SAFETY

The Swedish National Board of Housing, Building and Planning s general recommendations on the analytical design of a building s fire protection, BBRAD

Research Needs for the Fire Safety Engineering Profession

Based on NFPA 1001: Standard for Fire Fighter Professional Qualifications, 2013 Edition.

Europacable FAQ on CPR Status: 26/01/17

Transcription:

427 A publication of CHEMICAL ENGINEERING TRANSACTIONS VOL. 48, 2016 Guest Editors: Eddy de Rademaeker, Peter Schmelzer Copyright 2016, AIDIC Servizi S.r.l., ISBN 978-88-95608-39-6; ISSN 2283-9216 The Italian Association of Chemical Engineering Online at www.aidic.it/cet DOI: 10.3303/CET1648072 Fire Risk Assessment of Photovoltaic Plants. A Case Study Moving from two Large Fires: from Accident Investigation and Forensic Engineering to Fire Risk Assessment for Reconstruction and Permitting Purposes Luca Fiorentini a *, Luca Marmo b, Enrico Danzi, Vincenzo Puccia c a Tecsa SRL, Via Figino 101, 20016 PEro (Milano), Italy b Politecnico di Torino, Cso Duca degli Abruzzi 24, 10129 Torino, Italy c National Fire Brigade, Padova, Italy luca.fiorentini@tecsasrl.it Photovoltaic (PV) plants have known a steep increase in number and installed power in the last decade all over the world. Together with this growth, also associated risks grew significantly. Among these fire risk has caught the attention of both Authorities, plant managers and any other stakeholders (such has owners of the property) due to the high number of fire involving solar plants. In 2012 around 600 fires involving solar plants occurred in Italy, with this figure in constant growth. In this paper fire risk assessment of PV installations is presented through several steps since the problem has gained a significant importance. 1. A new fire scenario The turbulent growth of the photovoltaic roof installed plants as consequence of the public incentives to green energy placed some new fire risk scenarios for the building covered by the FV plants and opened a new field for the fire research and the fire investigators. After the first fire episodes, with large roof fires often followed by compartment fire, some resulting in the complete loss of the structure, the fire investigations revealed various till unconsidered fire risks related to DC arcing ignition of combustible roof insulation layers, often polyurethane or polystyrene foam. The heavy loss consequence of those events could be greatly reduced by a risk analysis approach in the early design stage of the plants, evaluating the fire risk and the consequence of the most common failure associated with a PV plant, as cell mismatch, Hot Spot, DC arcing and localized fires in connection boxes or PV modules. On the other hand, the run to the public incentives produced a shortening of the timing for design and preliminary hazard analysis of projects. Also, the pressure on installation timing related to the green energy public program of economic incentives increased the number of workers operating in the photovoltaic field without an appropriate training. At the same time the lack on the field of materials code and standardization for the specific PV application of materials and know-how of in installers teams led to an undervaluation of the fire risk for the PV plant and for the building housing the plant. 2. Some statistical data The available data on photovoltaic plants fires includes a large range of fire episodes, including connection box fires, fire involving only a few PV modules and large fires (the majority) occurred to plants located on the roof of the building, which spread inside throughout the skylights in the roof. The above data refer nevertheless to a large group of accidents of different magnitude regarding fires which involved, but not necessary started from, photovoltaic plants in Italy. The analysis of the data give the evidence of a peak of fires in 2012, following the first wave of installations. As the fire involved in fact new plants, they should be considered as early fires in consequence of lack of qualification of designers/installers. Please cite this article as: Fiorentini L., Marmo L., Danzi E., Puccia V., 2016, Fire risk assessment of photovoltaic plants. a case study moving from two large fires: from accident investigation and forensic engineering to fire risk assessment for reconstruction and permitting purposes, Chemical Engineering Transactions, 48, 427-432 DOI:10.3303/CET1648072

428 Root causes often comprehend the incorrect management of shading, the exposure of plant components to out of standards conditions (heavy water condensation under the panels), low quality components, crushing of cables during the installation, under evaluation of typical DC current behaviour, mismatch of PV cells. The final effect of those phenomena is often a diffused ground dispersion of DC current, with an immediate loss of power generated and associated to a DC arcing, following the insulation thermal stress induced by over currents flowing as effect of multiple faults. The multiple fault probability couldn't be considered negligible, It s an important difference between AC and DC circuits, due to the very high number of connection and components offer a large set of scenarios conducting to ground dispersion and to the impossibility to power off the plant. As from the Figure 1 data the trend of fires involving photovoltaic plants appears to drop after 2012. This could be a consequence of several factors including: 1) out of service of low quality plants as they went on fire, 2) improvement of the actors of the market of PV related services, 3) selection of the producers and installers after the prices decrease consequent to the decrease of public incentives, having the survived societies a general better qualified personnel. At the same time the lack on codes and standards started to be fulfilled by national regulation, including national standards which considered the results of fire reaction tests more complete than UL 790 and ASTM E 108 requirements. 800 700 600 500 400 300 200 100 0 2003 2004 2005 2006 2007 2008 2009 2010 2011 2012 2013 2014 Figure 1: Fire related to Photovoltaic Plants in Italy, Courtesy of Italian National Fire Corp, Statistical Service. Moreover, after the first relevant fire events all over the world, most of PV panels producer started to include fire resistance requirements in the user manual installation prescriptions. The decreasing number of fires is probably the evidence that the peak on fire number war related to faulty components or poor installations in the dash to economic green energy incentives, but as the knowhow of workers and designers increased, it could be expected a second peak in next years (5 or 10 y) as the ageing of components, mainly insulations, will lead to an increase of faults. 3. Some case studies Various fire events involved roof housing photovoltaic plants, some with bad damage of the building roof and with the consequence of large compartment fires inside the structure, consequence of fire spread inside the building. In Figure 2 a 1000 m2 warehouse housing a PV plant keep on fire. The evidence of the fire investigation conducted evidenced various elements in charge of PV Plant. In that case a conventional PV plant was installed on a thermally insulated roof. The episode evidenced the lack on fire regulation related to the introduction of photovoltaic plants on existing roof coverings, designed and installed years earlier with the aim of a better thermal insulation by mean of thick combustible foam layers but potentially offering a tremendous fire load. The typologies of fires resulted in various magnitudes from a small fire ignited in an electric box (Fig. 3) to the complete ignition of the cover, spreading the fire inside the compartment with a top down pattern, until now uncommon (nearly unknown) in the fire investigation literature.

Another new evidence resulted in the fire of some photovoltaic panels as effect of mismatch of single cell, or an incorrect installation or an electric fault creating loops or connection between different strings, with the immediate consequence of the behaviour as an electric charge of various panels, the overheating, the loss of electric insulation and the final scenario of the fire of combustible layers of the panels (Ethil vinyl Acetate, Tedlar). Also non-conventional PV plant adopting the in-roof technology were involved in fires of, in some circumstance, large magnitude. This is the case of the fire of a 6000 m2 roof plant depicted in Figure 5. The resulting fire produced large plumes spreading on city skyline, which produced citizen concern on environmental pollution and public safety. 429 Figure 2: a 1000 sq meters warehouse housing a PV plant keep on fire. The evidence of the fire investigation conducted reported various elements in charge of PV Plant. Figure 3: the Fire of a Connection Box in a ground PV Plant.

430 Figure 4: the The DC arcing effects on a external side of a polyurethane sandwich. Figure 5: A large warehouse involved by a fire, probably external at the PV plant but strongly influenced in his growth and propagation by the photovoltaic layers. 4. Dynamics of fire growth and propagation As from the fire risk assessment, the photovoltaic plant components (on a roof or on a building façade) are for sure able to: -modify the propagation of fire outside or through the building; -interfere with the smoke and venting systems of the combustion products; -obstacle the fire extinction operations; -introduce a further hazard through electrical shock for fire-fighters and rescue operators for the presence of circuit energized components. As the case depicted in Figure 5 concerns, a preventive fire risk assessment on the photovoltaic roof configuration should have early identified the inherent fire hazard produced by coupling a strong fire load to a new ignition source (i.e. the fire load inside the compartment and the in-roof installation of PV panels). Various concerns arise from the "ante" and "post" solarisation conditions, following different propagation scenarios: -Compartment fire spreading through openings and propagating on the roof; -Fire starting from PV modules integrated on the roofing and propagating to compartment.

The investigation had established whether the solarisation of the roof led to an increase of the fire risk and how the PV modules, the insulating roof coverings and the underlying compartments interact with each other in case of fire. Ante and post solarisation fire events were individuated and classified in function of different fire propagation, as shown in Table 1. Frequencies of these events were estimated using fault tree analysis coupled with an event tree analysis in which probabilities have been derived from recognized literature data (Ramachandran). Figure 6 shows the event tree related to the Top Event defined 2C in Table 1. Table 1: Ante and post solarisation fire event individuated and respective frequencies. Top EventDescription Frequency Probability class 1A Fire extended inside the compartment 2.64*10-1 Probable 431 1B Internal fire propagating outside 5.81*10-2 Probable 1C Fire propagating outside and spreading on roofing 2*10-2 Probable 2A as 1A with PV panels 2.64*10-1 Probable 2B as 1B with PV panels 5.81*10-2 Probable 2C as 1C with PV panels 2.0*10-2 Probable 2D Ignition due to PV modules, propagating along the6.36*10-11 Extremely improbable roofing Figure 6: Event tree analysis, from fire propagating in covering to fire extended to adjacent compartment (secondary event). This "Top Down" fire spread scenario /from roof to underlying compartment) probably constitutes a rather new entry in fire investigation science, as produced by the interaction of a combustible insulating layer, earlier installed on the top of the building and the ignition sources inducted by the photovoltaic plant. The incorrect installation, or simply a fault in a component, could easily ignite a severe DC arcing, with a stable current flow enough intense to drill a metal layer of a sandwich, and consequently ignite the combustible layer below it. Also, the light openings or even the fire and smoke evacuation system could be a way of internal spread of the fire ravaging the insulating cover, so the combined effect of those elements resulted in most of the destructive fire originated by the photovoltaic plants. Due to this, in order to verify any eventual impacts on existing buildings, it is important to verify how the new PV installation modifies the existing fire risk. In order to perform this evaluation a fire risk assessment of both existing and future situations should be conducted. As briefly described this can be accomplished with a three step analysis: identification of the fire propagation mechanisms that are applicable to the specific case (specifically those associated to the layout); identification of the main top events (TEs) including secondary and domino effects; evaluation of the probable failures of the PV plant components and those risks associated with the already in place existing components, systems, etc.; identification of the frequencies of both TEs and

432 associated resulting scenarios for ante-post comparison and verification against a tolerability criteria definition. This activity can be performed by the use of FTA and ETA coupled with data coming from literature and increasing operational experience. 5. The fire requirements of PV panels The fire regulation on PV panels is based on simple test included in UL 790 or ASTM E 108. A number of tests were conducted after the concerns following the first fires by UL and Solar America Board for Codes and Standards (Solar ABCs), with various results, all indicating the negative influence of a PV panel over a roof covering in terms of heat dissipation, smoke trapping, and fire spreading. Also the results underlined that the coupling of two good fire rating elements could even result in a worse fire rating for the overall package. The evidence of DC arcing impact is driving on a most appropriate fire evaluation of covering and to dedicated active elements for early DC arcing detection. On this basis the NFPA 70 (National Electric Code) introduced the Arc Fault Detection Interrupter as mandatory on last edition, after a number of fire resulted on private dwellings as effect of photovoltaic system malfunction/fault. 6. Lessons learnt and conclusions The photovoltaic technology for green energy production could produce severe fires on roof building not rated to be coupled with a inherent ground dispersion source. As a completely incombustible roof could be a good solution to limit the risk to the acceptable fire risk connected with this technology, an early fire risk assessment conducted by the risk analysis tools could be a strong tool to improve fire safety on by now installed roof plants. The fire investigation results evidenced on various devastating fire the need of a comprehensive revisit of fire codes on photovoltaic building roof installed, mainly with insulating or combustible coverings immediately under the active components of the plant. The photovoltaic producers indicating strong fire requirements on installation manuals after the first relevant fire episodes introduce various question on the standard conformity and in fire code enforcement on existing photovoltaic roof, with various items on plant documentation legal soundness. References ANSI/UL 790 Standard Test Methods for Fire Tests of Roof Coverings, 2004 ASTM E 108 Standard Test Methods for Fire Tests of Roof Coverings, 2011 NFPA 70 National Electric Code, 2014 Ramachandran G., Charters D., 2011, Quantitative Risk Assessment in Fire Safety. Taylor and Francis Ltd, United Kingdom.