Progressive Safety Services LLC 1

Similar documents
Explosion Prevention & Suppression James Maness JEM Safety Consulting Rehoboth, DE.

Explosion Venting and Suppression of Bucket Elevator Legs, G90-990

Brian Knapp & Johnny Wheat

DEPARTMENT OF LICENSING AND REGULATORY AFFAIRS DIRECTOR'S OFFICE GENERAL INDUSTRY SAFETY AND HEALTH STANDARD STANDARDS

MID-ATLANTIC GEAPS JANUARY 2013 MEETING PRESENTED BY: Johnny Wheat. 4B Components Limited

General Design Practices in Reducing Risk in Grain Handling Facilities

Understanding. Combustible Dust Hazards: Basic Measures to Ensure the Safety of Combustible Dust Handling Operations

HAWAII ADMINISTRATIVE RULES DEPARTMENT OF LABOR AND INDUSTRIAL RELATIONS DIVISION OF OCCUPATIONAL SAFETY AND HEALTH

COMBUSTIBLE DUST HAZARD RECOGNITION

COMBUSTIBLE DUST SAFETY PROGRAM

Industrial Explosion Suppression Technology

Property risk solutions

Progressive Safety Services LLC 2

Objectives. NFPA Dust Specific Documents. Combustible Dust Process Hazard Safety Overview of NFPA Standards for Combustible Dusts

Aluminum Dust Management in a Metallizing Facility

Combustible Dust 101: Understanding Combustible Dust Hazards

Managing Combustible Dust

Ontario Fire Code SECTION 5.10 COMBUSTIBLE DUST PRODUCING PROCESSES. Illustrated Commentary. Office of the Ontario Fire Marshal

Combustible Wood Dust Management Program Development Guide

Conducting a NFPA 652 Dust Hazard Analysis (DHA): Practical Tips & Approaches

Industrial Dust Explosions Causes & Case Studies. Presented by Geof Brazier at Expocorma, Concepcion, Chile 10th November 2017

Prevention of Fires and Explosions in Wood Pellet Facilities. Allen Wagoner, FLAMEX, Inc.

The correlating committee has revised the numbering in these sections to provide clarity for the next edition of the document.

Combustible Dust Hazards: Awareness & Safeguarding. Forest Industry Task Force on Mill Safety May 2012

Combustible Dust Hazards- Awareness

International Symposium. OSHA Combustible Dust NEP Inadequacies. John Astad

Protecting Facilities Against Explosions. Since 1956

OSHA - Enforcement Define the terminology Recognize a Dust Explosion hazard Learn hazard management methods

A Global Leader in Explosion Protection

Protecting Critical Facilities Against Explosions

Combustible Dust Hazard Recognition and Control NFPA Standards for Combustible Dusts

COMBUSTIBLE DUST HAZARD MITIGATION

Monitoring Equipment

Dust Explosions. health & environmental sciences failure analysis & prevention

HARDWOOD INDUSTRY FACILITY & SAFETY INSPECTION CHECKLIST

Fire Prevention Plan

NFPA Mexico Fire Expo April 20, Learning Objectives. Combustible Dust Explosions History

Fire Prevention Plan

OUTDOOR INSTALL NO RETURN AIR SINGLE MODULE COLLECTORS OUTDOOR INSTALL WITH RETURN AIR SINGLE MODULE COLLECTORS

Combustible dust in wood products manufacturing. A shop-floor guide for employers and supervisors

Combustible Dust Resources OVERVIEW OF COMBUSTIBLE DUST. What is Combustible Dust? Where are Combustible Dusts found?

With CV Technology products and care, you ll be better protected from dust explosions.

Electrical Preventive Maintenance (EPM) Program

PROTECTING YOUR PROPERTY INVESTMENT BEFORE DISASTERS OCCUR ARE YOU PREPARED?

Emergency Action and Fire Prevention

Special Occupancy Requirements

DUST COLLECTION TRAINING. Revision 2013

Fire Prevention Plan for Alumni Center 1507 Dana Avenue

Woodworking Safety. Machine Guarding. Work Practice Controls. Loss Control Bulletin

APPLICATION PROFILE EXPLOSIONS IN CEMENT PLANTS EXPLOSIONS IN CEMENT PLANTS CEMENT PLANT EQUIPMENT WITH HIGHEST EXPLOSION POTENTIAL. Form No.

Combustible Dust with FR Clothing June Service Experience Trust Quality Flexibility

AUTOMATIC FIRE SUPPRESSION SYSTEMS

The element is closed at one end and open at the other, and it s bolted onto the explosion vent opening on the equipment so that its open end overlaps

Wood Dust Mitigation and Control Audit Auditor Worksheet, Questionnaire and Guideline

PRIMATECH WHITE PAPER PROCEDURE FOR DUST HAZARD ANALYSIS (DHA)

Stillwater Area Community Services Center Inc.

Fire Prevention Plan for Alter Hall 3743 Ledgewood Drive

Dust Explosion Hazard Overview

Combustible Dust Issues

Fire Prevention Plan for Campus Services Building 1630 Musketeer Drive

Air Pollution Control Equipment & Service Needs

Fire Prevention Plan for St. Barbara Hall 3904 Winding Way

Airborne combustible dust in the right

Presented by: Timothy Maley, Deputy Commissioner Michelle Ellison, Assistant Commissioner

Fire Prevention Plan for Residence Life 1625 Musketeer Drive

Jason Reason. NFPA Technical Committees

Chapter 18 Welding Table of Contents

Leading Trends in Chemical Processing

Fire Prevention Plan for Bellarmine Parish Center 3832 Ledgewood Avenue

Fire Safety. Version 1.0

Xavier Field Office Fire Prevention Plan. for. Xavier Field Office Dana Avenue

HeatExchangerSpares.com Ltd HRS Heat Exchangers Ltd HRS Hevac Ltd HRS Hevac Engineering Ltd HRS International Ltd HRS Investments Ltd

Prevention of Fires and Dust Explosions within the Biomass Handling Process. PFI July 20, 2015

Kice Dust Control System Design and Maintenance Basics Design, Maintenance, & Operation

Making sense of risk Risk engineering. Metalworking operations

Fire Prevention Plan for

ADMINISTRATIVE SERVICES MANUAL

Today, we re going to talk about emergency action and fire prevention. We hope we never have to face an emergency situation like a fire in our

Overview of Hazardous Locations as They Relate to Solenoid Valves

PRELIMINARY REVIEW OF APPLICABLE CODES AND STANDARDS, PROCESS HAZARD ANALYSIS AND OPERATIONAL FIRE SAFETY PLAN

Safe Operating Procedure

CHAPTER 15: FIRE PREVENTION & AWARENESS POLICY

INTRODUCTION TO DUSTS AND THEIR EXPLOSIVE PROPERTIES

Contractor Worksheet Underground Fires Major Hazard Standard

Dust Explosions. by Clive de Salis. Telephone: +44 (0)

GEAPS Great Lakes Regional Conference 2017 Explosion Protection Overview & Market Drivers. April 6, 2017

Checklists LAUNDRY GREENKEYGLOBAL.COM

1.2 To ensure the safety of all persons working in or occupying a building where a hot work operation is performed.

British Columbia Institute of Technology. BCIT Safety Manual APPENDIX A- PLANNED MAINTENANCE

Fire Prevention Policy

Document Number: HSP Prepared by: Jim Landry Manager Approval: Hillary Garner HEALTH AND SAFETY PROGRAM HSP 506 FIRE PREVENTION PLAN

Before proceeding with the selection process, let s briefly look at the various explosion protection options:

Combustible Dust Awareness. David McEwan Business Line Manager Configured Products

Combustible Dusts. Some recent examples of dust explosion losses in the U.S. include:

American Society of Safety Engineers Professional Development Conference June 9-12, Fire Protection. Stephen J.

COMBUSTIBLE DUST HAZARD RECOGNITION

Flameless Venting The New Technology for Safe Indoor Explosion Venting

BiomassProduction and Safety

FIRE PREVENTION. by Thomas Frank, P.E. A Handful of Dust Can Destroy Your Facility

THE ALLIANCE FOR BANGLADESH WORKER SAFETY BOILER SAFETY

Transcription:

Progressive Safety Services LLC 1

Progressive Safety Services LLC 2

Late 1970 s a series of devastating grain elevator explosions left 59 people dead and 49 injured. In 1987 OSHA published the Grain Handling Standard 29 CFR 1910.272 addressing several hazards associated with the handling of grain. 1910.272 Appendix A Means of achieving performance goals outlined in the standard. Progressive Safety Services LLC 3

Grain Dust Explosions Progressive Safety Services LLC 4

Heat (Ignition) Dispersion of Dust Particles Fuel Combustible Dust in Suspension Oxygen Confinement Removal of any one element can prevent an explosion Dust in Suspension Combustible Dust Heat Oxygen Confinement

Grain Dust: Emitted from stock handling systems. 425 microns or less As particle size decreases the risk explosion increases Progressive Safety Services LLC 6

The dust concentration contributes to potential for an explosion. Minimum Explosive Concentration (MEC): MEC = 50 g/m3 Concentrations generally only reached in grain handling or processing equipment: Bucket elevators Conveyor housings Transfer/discharge points Progressive Safety Services LLC 7

Necessary for Combustion Difficult to eliminate Progressive Safety Services LLC 8

Welding and Cutting Overheated Bearings Faulty Electrical Equipment Smoking Sparks from Tramp Metal Choked Legs Misaligned or Slipping Conveyors Progressive Safety Services LLC 9

Dust Type Ignition Source of Cloud (F) Minimum Explosive Concentration oz/cu ft. Relative Explosion Hazard Corn 752 0.045 Strong Corn Starch 716 0.040 Severe Wheat 896 0.055 Strong Wheat Flour 716 0.050 Strong Grain Mixed 806 0.055 Strong Progressive Safety Services LLC 10

Often beyond the control of the operator. Lessen the effects by using explosion venting techniques. Progressive Safety Services LLC 11

Inside grain handling equipment. Primary Explosion - caused by the ignition of dust under the right conditions. Pressure waves and fire waves are released. Secondary Explosions occurs when the blast wave from the primary explosion propagates and causes layers of dust to become suspended. Progressive Safety Services LLC 12

The pressure wave travels away from the primary explosion at 1,000 feet per second. Fire wave follows at 10 feet per second. Rupture pressures from secondary explosions can be in excess of 100 psi. Progressive Safety Services LLC 13

Grain Dust Explosions Progressive Safety Services LLC 14

OSHA Standard Requirements: Immediately remove fugitive grain dust accumulations that exceed 1/8 inch (0.32 cm). Develop a written housekeeping plan that establishes frequency and methods for removing fugitive grain dust on: Ledges Floors Equipment Exposed Surfaces Progressive Safety Services LLC 15

Housekeeping program must address priority areas: Areas within 35 feet of inside bucket elevators. Have a boot section. More than 20% of leg height inside the grain elevator structure. Floors of enclosed areas containing grinding equipment. Floors of enclosed areas having grain dryers inside the facility. Progressive Safety Services LLC 16

Use of Compress Air Used for Cleaning All machinery presenting an ignition source is shut down. All other known potential ignition sources are removed or controlled. Recommend using a compressed air cleaning permit. Progressive Safety Services LLC 17

Captures dust suspended in air at grain transfer points Decreases the dust concentration to below the minimum explosive concentration (MEC) Progressive Safety Services LLC 18

OSHA Grain Handling Standard Requirements for Fabric Dust Filters: Equipped with a monitoring device that will indicate the pressure drop across the filter (Magnahelic). Located outside the facility (After 1988) or; Located in an area inside the facility protected by explosion suppression system or; Located in an area inside area separated from other areas by a one hour fire resistance rating, which is adjacent to an exterior wall and vented to the outside. Progressive Safety Services LLC 19

Class II Division1 Group G Open System Class II Division 2 Group G Closed System Progressive Safety Services LLC 20

Progressive Safety Services LLC 21

Progressive Safety Services LLC 22

Application of food grade quality oil to the grain surface. Fine particles stick to the surface of the grain kernel rather than becoming airborne at transfer points. Usually positioned in receiving systems prior to transfer/discharge points. Progressive Safety Services LLC 23

Need to have a documented program to include use of the permit system. All efforts should be taken to remove equipment and perform hot work in areas outside of the grain handling structure. Engineering eliminate hot work with the use of bolts with new installations. Progressive Safety Services LLC 24

Plan hot work activities to ensure fire watch. Contractors must understand the company s hot work policy. Contractors have been responsible for fires and explosions. Progressive Safety Services LLC 25

Designate smoking areas away from the handling facility: Distance requirements Designated areas Post No Smoking signage so that employees, customers and contractors are aware. Communicate and enforce the policy with employees, contractors and customers. Progressive Safety Services LLC 26

Progressive Safety Services LLC 27

Metal tools, bolts, scrap, etc. are transported to grain facilities from the farm. Tramp metal can cause: Equipment overheating Sparks Damage to equipment Progressive Safety Services LLC 28

Ferrous (tramp) metal can be addressed in two ways: Receiving pit openings covered with grates with maximum openings of 2.5 inches (OSHA requirement) Use of high powered magnets that remove metal not stopped by use of the grate. Dual approach is most effective OSHA requires grain stream handling equipment (hammermills, grinders, pulverizers) to have an effective means of removing ferrous metal from incoming grain stream. Progressive Safety Services LLC 29

Progressive Safety Services LLC 30

Progressive Safety Services LLC 31

Progressive Safety Services LLC 32

Progressive Safety Services LLC 33

Equipment Issues may include: Overheated Bearings Misaligned Belts Frictional Rubbing Choked Legs Overloaded Belts Progressive Safety Services LLC 34

Two ways to address equipment issues: Documented Preventative Maintenance Programs Installation of Safety Control Equipment Progressive Safety Services LLC 35

Outlined in the OSHA Grain Handling Standard Employer shall implement preventative maintenance procedures Regularly scheduled inspections of at least the mechanical and safety control equipment associated with: Grain Stream Processing Equipment Filter Collectors Bucket Elevators Grain Drying Systems Progressive Safety Services LLC 36

Lubrication schedules and maintenance in accordance with manufacturer recommendations, or as determined by prior operating records. Promptly correct dust collection systems which are malfunctioning or operating below design efficiency. Employer shall promptly correct, or remove from service, overheated bearings, and slipping or misaligned belts associated with inside bucket elevators. Certification record needs to be maintained for each inspection to include: Date of inspection Name of person inspecting, repairing, etc. Serial number or other identifier of equipment Progressive Safety Services LLC 37

Infrared Thermography - the use of an infrared imaging and measurement camera to "see" and "measure" thermal energy emitted from an object. Can be used on: Electrical Systems Bearings Motors Progressive Safety Services LLC 38

Bearing Monitoring Systems Conveyor Zero Speeds Belt Alignment Systems Progressive Safety Services LLC 39

Bearings (OSHA requirement): Bearings should be mounted externally to the leg casing (Pillow Block) or; Vibration monitoring, temperature monitoring or other means to monitor the condition of the bearings mounted inside or partially inside the leg casing. Does not apply to bucket elevators with: Explosion suppression on head and boot sections Bucket elevators equipped with pneumatic dust control systems that keep the dust concentration in inside bucket elevators at least 25% below the MEC during operation. Progressive Safety Services LLC 40

Progressive Safety Services LLC 41

Motion Detection (OSHA Requirement) Bucket elevators must be equipped with a motion detection device. Must shut down the bucket elevator when the belt speed is reduced to no more than 20% of normal operating speed. Does not apply to bucket elevators with: Explosion suppression on head and boot sections, or bucket elevators equipped with pneumatic dust control systems that keep the dust concentration in inside bucket elevators at least 25% below the MEC during operation, or Grain elevators having a permanent storage capacity of less than 1 million bushels, provided that daily inspection of bucket movement and tracking of the belt. Progressive Safety Services LLC 42

Belt Alignment (OSHA Requirement): Equip bucket elevators with belt alignment devices which initiate an alarm to employees when the belt is not tracking properly or; Provide a means to keep belt tracking properly. Does not apply to bucket elevators with: Explosion suppression on head and boot sections. bucket elevators equipped with pneumatic dust control systems that keep the dust concentration in inside bucket elevators at least 25% below the MEC during operation, or Grain elevators having a permanent storage capacity of less than 1 million bushels, provided that daily inspection of bucket movement and tracking of the belt. Progressive Safety Services LLC 43

Systems should at a minimum be connected to an audible/visual alarm to alert employees. Helpful to tie systems into office areas that are always staffed. Progressive Safety Services LLC 44

Design concept is a design concept used with elevator legs to vent the pressure and fire front of the primary explosion outside of the elevator reducing the probability of the more devastating secondary explosions. Explosion Vents replace a portion of a leg casing. Designed to rupture or release at low pressures. Maintain the structural integrity of the leg casing. Can also vent bins, silos, dust collection equipment, etc. Progressive Safety Services LLC 45

Venting interior legs is not easy. Venting should be to the outside. The ducting should be no longer than 10 feet and have no bends or elbows. Progressive Safety Services LLC 46

Vent Panels Rupture strength of no more than 1psi. Vary from aluminum to PVC. Should be secured by chain or cable. Make sure not positioned near work areas. Progressive Safety Services LLC 47

Progressive Safety Services LLC 48

Progressive Safety Services LLC 49

Progressive Safety Services LLC 50

Detects grain dust explosion early. Floods area with an extinguishing agent. Can effectively suppress grain dust explosions in bucket elevator legs. Progressive Safety Services LLC 51

Grain dust explosion can be detected by sensors: Optical Thermal Pressure Most Common Diaphragm type device responds to initial pressure by quickly closing electrical contacts. Progressive Safety Services LLC 52

Sensor detects the pressure front and sends a signal through a control unit to a high rate discharge extinguisher Dispenses in 3-5 milliseconds Uses dry powders Sodium Bicarbonate Mono-ammonium phosphate Battery powered, interlocked to equipment. Progressive Safety Services LLC 53

Progressive Safety Services LLC 54

Progressive Safety Services LLC 55

Training Employer shall provide training annually on: Recognition of hazards related to dust accumulations Common Ignition sources such as smoking Cleaning procedures Housekeeping procedures Preventative Maintenance Properly rated tools and equipment Emergency Procedures PPE/Clothing Progressive Safety Services LLC 56

Inside Bucket Elevators Shall not be jogged to free a choked leg. All belts and lagging purchased after 1988 shall be conductive. All bucket elevators shall have a means of access to the head pulley to allow inspection of the head pulley, lagging, belt and discharge. Boot section of bucket elevator shall also be provided with a means to access for clean-out of the boot and for inspection of the boot, pulley and belt. Progressive Safety Services LLC 57

Progressive Safety Services LLC 58

Progressive Safety Services LLC 59

Progressive Safety Services LLC 60

Progressive Safety Services LLC 61

Progressive Safety Services LLC 62

Progressive Safety Services LLC 63

Progressive Safety Services LLC 64

Joe Mlynek CSP, CLCS Progressive Safety Services LLC (216) 403-9669 Email: progressive_safety@sbcglobal.net Website: progressivesafety.us Progressive Safety Services LLC 69