MEETING OF THE TECHNICAL COMMITTEE ON RESPIRATORY PROTECTION EQUIPMENT. NFPA 1989 and 1852 Second Draft Meeting. May 23-24, Virginia Beach, VA

Similar documents
MINUTES OF THE MEETING TECHNICAL COMMITTEE ON RESPIRATORY PROTECTION EQUIPMENT JULY 2015 SACRAMENTO, CA

MINUTES OF THE MEETING TECHNICAL COMMITTEE ON RESPIRATORY PROTECTION EQUIPMENT JULY 2011 MISSOULA, MT

MEETING OF THE TECHNICAL COMMITTEE ON RESPIRATORY PROTECTION EQUIPMENT. NFPA 1989, 1852 First Draft Meeting. August 9-10, 2016.

Second Revision No. 1-NFPA [ Section No. 2.2 ] Submitter Information Verification. Committee Statement

TECHNICAL COMMITTEE ON ELECTRONIC SAFETY EQUIPMENT. December 10-12, 2013 San Diego, CA AGENDA

MEETING OF THE TECHNICAL COMMITTEE ON RESPIRATORY PROTECTION EQUIPMENT. NFPA 1981 First Draft Meeting. March 7-9, 2016.

First Revision No. 1-NFPA [ Section No ] Submitter Information Verification. Committee Statement 4/15/ :08 AM

TECHNICAL COMMITTEE ON SAFETY AT MOTORSPORTS VENUES. NFPA 610 First Draft Meeting. October 17-18, 2016

National Fire Protection Association (NFPA) Fire Service Occupational Safety and Health Technical Committee Meeting March 14 15, 2012 San Diego, CA

National Fire Protection Association (NFPA) Fire Service Occupational Safety and Health Technical Committee Meeting October 8 9, 2010 San Diego, CA

TECHNICAL COMMITTEE ON ELECTRONIC SAFETY EQUIPMENT. Wyndham San Diego Bayside 1335 N. Harbor Drive San Diego, CA NFPA 1982 Second Draft Meeting

MINUTES OF THE MEETING TECHNICAL COMMITTEE ON HAZARDOUS MATERIALS PROTECTIVE CLOTHING AND EQUIPMENT JANUARY SAN DIEGO, CA

Homeland Security Standard Panel (ANSI-HSSP) November 9, Standards Development in Response to Terrorism Threats

NFPA 1500 UPDATE CONTROLLING EXPOSURE TO FIREGROUND TOXIC CONTAMINANTS

3M Personal Safety Division. Standards Update. NFPA 1981/1982, 2018 Edition. March 30, 2018

1 of /10/2016 1:14 PM

NFPA TECHNICAL COMMITTEE ON ELECTRONIC SAFETY EQUIPMENT. March 18-19, 2014 Fort Lauderdale, FL AGENDA

Enactment Date: Rapid Intervention Team and RIT Officer

S a n F r a n c i s c o F i r e D e p a r t m e n t B u r e a u o f F i r e P r e v e n t i o n & I n v e s t i g a t i o n 1 of 8 P a g e

CHAPTER 05 - OFFICE OF STATE FIRE MARSHAL SUBCHAPTER 05A - FIRE AND RESCUE SECTION.0900 PUBLIC PROTECTION CLASSIFICATIONS FOR FIRE DISTRICTS

5.07 Air Replenishment Systems

TECHNICAL COMMITTEE ON FIRE CODE

MATRIX TO DETERMINE YOUR PRESENT POSITION IN MEETING N.F.P.A. 1720

IAFF DIVISION OF OCCUPATIONAL HEALTH, SAFETY AND MEDICINE

NFPA Technical Committee on Building Systems. NFPA 900 First Draft Teleconference/Web Meeting AGENDA. Thursday, February 13, :00 a.m.

National Fire Protection Association (NFPA) Fire Service Occupational Safety and Health Technical Committee Meeting. October 10 12, 2011 Baltimore, MD

Based on NFPA 1001: Standard for Fire Fighter Professional Qualifications, 2013 Edition.

TECHNICAL COMMITTEE ON MANUFACTURE OF ORGANIC COATINGS First Draft Meeting Agenda March 19, :00 AM - 5:00 PM EST Web/Teleconference Meeting

GIS Data Exchange Committee. and the NFPA Standards Making System

Introductions made by the Chair, committee members, NFPA Staff Liaison, Jacqueline Wilmot and Dan Gorham of the Fire Protection Research Foundation.

NFPA Technical Committee on Hybrid (Water and Inert Gas) Fire Extinguishing Systems

NATIONAL FIRE PROTECTION ASSOCIATION Fourth Survey of the Needs of the U. S. Fire Service


NFPA Who we are and how we can help you

M E M O R A N D U M. Technical Committee on Supervising Station Fire Alarm and Signaling Systems

Career Fire Fighter Dies From Injuries Sustained In Fall From Apparatus - Massachusetts

Overview of Process for Certification to NFPA Standards for Fire and Emergency Services PPE. IOM Workshop on Certification of PPT April, 13, 2010

Date: DRAFT Initiated by: AAS-300

DuPont NFPA Certified Attire

Public Input No. 52-NFPA [ Section No [Excluding any Sub-Sections] ]

Meeting Minutes. High Rise Building Safety Advisory Committee


Hydrostatic Retest Requirements for ANSUL Pressure Vessels

NFPA 600. Standard on Industrial Fire Brigades Edition. Copyright 2000 NFPA, All Rights Reserved

9S / 9E Inspection Worksheets. The fire department should complete the following sheets prior to inspection date

The ODP/OLES 5-Year Plan for CBRNE Standards

Centers for Regional Excellence. Downriver Fire Authority. Organization Committee Objective. Operations Committee Report 2007

MEETING AGENDA High Rise Building Safety Advisory Committee

Second Revision No. 1-NFPA 17A-2016 [ Section No ] Submitter Information Verification. Committee Statement. 1 of 14 6/22/2016 3:15 PM

MEETING AGENDA High Rise Building Safety Advisory Committee

SPEARFISH FIRE DEPARTMENT POLICIES AND PROCEDURES

TECHNICAL COMMITTEE ON STRUCTURAL AND PROXIMITY FIRE FIGHTING PROTECTIVE CLOTHING AND EQUIPMENT AGENDA

!!!!! Program Checklist

TECHNICAL COMMITTEE MEMBERS WHO PARTICIPATED

SMALL TOOL REPLACEMENT PLAN

CHAPTER 1 ADMINISTRATION AND ORGANIZATION

REQUIREMENTS. For FIRE DEPARTMENTS. State of West Virginia. Bob Wise Governor THE DEPARTMENT OF MILITARY AFFAIRS AND PUBLIC SAFETY

NFPA Self Assessment Manual

1. Welcome. Robert Smith, Chair. 2. Introductions and Update of Committee Roster. (attached)

NFPA 550 ROP Meeting Minutes

Call to Order Chair Jack Poole called the meeting to order at 8:00 AM on Monday, July 17, 2017.

Page 1 of 6 10/19/2016 9:49 AM. Public Input No. 4-NFPA [ Section No ] Statement of Problem and Substantiation for Public Input

First Revision No. 2-NFPA [ Global Input ] Submitter Information Verification. Committee Statement. 1 of 11 1/18/2016 5:43 PM


Second Revision No. 104-NFPA [ Section No ] Submitter Information Verification. Committee Statement

Excerpted from NFPA 1403 Standard on Live Fire Training Evolutions

Public Input No. 4-NFPA [ Section No. 4.2 ] Statement of Problem and Substantiation for Public Input. Submitter Information Verification

Minutes of the Pre-ROP Meeting of the T/C on Protected Premises Signaling September 22-23, 2010 Indianapolis, IN

PRINCE WILLIAM COUNTY FIRE AND RESCUE ASSOCIATION RESOLUTION LOG

Committee Input No NFPA [ Global Input ] Submitter Information Verification. Committee Statement. 1 of /20/ :02 AM

Technical Committee on Fluidized Bed Boilers

NFPA Technical Meeting (Tech Session) June 24-25, 2015 Agenda*

Agenda Technical Committee on Initiating Devices for Fire Alarm and Signaling Systems June 24-25, 2013 Saint Louis, MO

First Revision No. 20-NFPA [ Section No ]

Fire Service Training Update

M E M O R A N D U M. NFPA 1911 Second Draft Technical Committee FINAL Ballot Results (F2016 Cycle)

2014 NFPA Conference & Expo

Answer: B Objective: NFPA 472, (c), 4.2.3, 5.2.3(1); Level: Awareness, Operations Subject: Introduction; Chapter 1; Page 5

M E M O R A N D U M. Technical Committee on Fire Fighter Professional Qualifications


M E M O R A N D U M. NFPA Technical Committee on Fire Department Apparatus. Yvonne Smith, Project Administrator. Date: June 4, 2014

Adobe Connect - Invitation to NFPA 385 Second Draft Web Conference


STANDARD OPERATING PROCEDURES RESPONDING TO EMERGENCIES DEPARTMENT RESPONSE PROCEDURES EFFECTIVE: AUGUST 2007

Meeting Agenda Technical Committee on Fire Service Occupational Safety and Health January 8 th -10 th, 2013 San Diego, Ca.

Rapid Intervention Team

Resolution: FR-2-NFPA Statement: The new language requires the action completed by NFPA 557 be prepared by a person that is approved.

The Technical Committee on Fire Service Training


Public Input No. 122-NFPA [ Global Input ]

FREDERICK COUNTY / WINCHESTER FIRE AND RESCUE DEPARTMENTS BASIC FIRE ACADEMY #15 CERTIFICATION COURSE SEPTEMBER 2015 APRIL 2016

NFPA Fire Inspector I Study Guide

Pre-First Draft Meeting Technical Committee on Wastewater Treatment Plants On line/conference Call November 20, PM EDT


MEETING MINUTES NFPA Technical Correlating Committee on Safety to Life January 6, 2011 ROC Meeting The Wyndham Phoenix, Phoenix, AZ

MEMORANDUM. Technical Committee on Emergency Power Supplies. NFPA 111 First Draft Technical Committee FINAL Ballot Results (A2018)

SUNDAY, MARCH 19 MONDAY, MARCH 20

Lassen Community College Course Outline

Preliminary Agenda Technical Committee on Liquefied Petroleum Gas

M E M O R A N D U M. Technical Committee on Flash Fire Protective Garments

Transcription:

MEETING OF THE TECHNICAL COMMITTEE ON RESPIRATORY PROTECTION EQUIPMENT NFPA 1989 and 1852 Second Draft Meeting May 23-24, 2017 Virginia Beach, VA AGENDA Conference call info: Phone: 855-747-8824 Passcode: 902034 Tuesday, May 23, 2017, Start Time 9:00 a.m. 1. Self-introduction of members and guests 2. NFPA Staff Liaison report Dave Trebisacci 3. Chairman s opening remarks Dan Rossos 4. Approval of the Minutes of the January 17-18, 2017 meeting San Diego, CA (attached) 5. NFPA 1989 Review of Public Comments (attached), Second Revisions 6. NFPA 1852 Review of Public Comments (attached), Second Revisions 7. Old business 8. New business 9. Upcoming Meetings 10. Adjourn at close of business, Wednesday, May 24, 2017

MINUTES OF THE MEETING TECHNICAL COMMITTEE ON RESPIRATORY PROTECTION EQUIPMENT 17 18 JANUARY 2017 SAN DIEGO, CA AGENDA ITEM 1; SELF-INTRODUCTION OF MEMBERS AND GUESTS Chairman Rossos called the Committee to order at 09:00 on 17 January 2017. Chairman Rossos welcomed Committee members and guests and asked them to introduce themselves. Members Present: Dan Rossos, Chairman Steven H. Weinstein, Secretary David Trebisacci, Staff Liaison Oregon Dept. of Public Safety Stds. & Training Honeywell Safety Products NFPA Chris Anaya California State Firefighters Association David Bernzweig Columbus (OH) Firefighters Robert Sell Draeger Safety David Hodson Draeger Safety UK Ltd. Stephen T. Miles NIOSH FFFIPP Robin Gainey International Association of Fire Fighters Clint Mayhue Avon Protection William Mundy Fire Department City of New York Brian Cox Clovis Fire Department Ryan Brubaker Clovis Fire Department A. Ira Harkness U.S. Department of the Navy Stephen Sanders Safety Equipment Institute (SEI) Jason Allen (online) Intertek Testing Services Ruby Ochoa (online) Trace Analytics Judge Morgan Tyco/Scott Safety Jay Tarley NIOSH Marco Tekelenburg Mine Safety Appliances Company Gregory Vrablik Honeywell Safety Products Mark Trudgeon Luxfer Gas Cylinders Craig Colton 3M (rep. ISEA) Clint Kaller Los Angeles County F.D. Bryan Profit Portland Fire & Rescue Michael Szymanski Virginia Beach F.D. Thomas Mooney International Association of Fire Fighters Michael Swofford Interspiro, Inc. Kevin Lentz Grace Industries, Inc. Kenneth Hayes Boston Fire Department Ed Golla TRI Air Testing, Inc. Joseph Domitrovich U.S. Department of Agriculture William Dickson Bauer Compressors, Inc. Page 1 of 3

The following guests were present: Jeff Peterson Ian Fulton Matt Taylor Jonathon Sauseda Josh Burnheimer John Morris Neb Petrovački Jim Taylor Mike Allen Tyler Griffith Al Yanagisawa Martyn Lamb Stuart Blenkiron George Broyles NIOSH/NPPTL U.S. Department of the Navy Avon Protection TRI Air Testing, Inc. Scott Safety Scott Safety Honeywell Honeywell Sturges Manufacturing Sturges Manufacturing Los Angeles County F.D. Draeger U.S. (Houston) Draeger UK U.S. Forest Service AGENDA ITEM 2; NFPA STAFF LIAISON REPORT Staff Liaison David Trebisacci provided the staff liaison report and asked attendees to sign in on the appropriate Member or Guest sign-in sheet. He reviewed the following: TC composition and balance; NFPA 1981, 1852, 1989 and 1984 cycle dates; creating a second revision; the balloting process; and legal issues associated with the NFPA standards process. AGENDA ITEM 3; CHAIRMAN S OPENING REMARKS Chairman Rossos announced the schedule for the day. He addressed the desire of the TC on Tactical & Technical Operations Respiratory Protection Committee to modify NFPA 1852 to become a joint SCAM document for NFPA 1981 and NFPA 1986. He asked Jeff Peterson to give a report on recent NIOSH activities related to the TC on RPE. AGENDA ITEM 4; APPROVAL OF THE MINUTES OF THE 9-10 AUGUST 2016 MEETING IN QUINCY, MA Chairman Rossos asked the TC to review the Minutes of the Quincy (MA) meeting. MOTION BY STEVE MILES, SECOND BY ROBIN GAINEY To approve the Minutes of the 9 10 August 2016 meeting in Quincy, MA. MOTION CARRIED. AGENDA ITEM 5; REVIEW OF PUBLIC COMMENTS, SECOND REVISIONS The TC acted to address the public comments submitted for NFPA 1981 and created second revisions based on those comments. The TC also created second revisions based on committee comments. David Trebisacci recorded the TC s actions. Page 2 of 3

AGENDA ITEM 6; OLD BUSINESS There was no old business. AGENDA ITEM 7; NEW BUSINESS Steve Miles stated that the Pneumatic Data Logging Task Group will be disbanded after this meeting. Marco Tekelenburg pointed out that there are discrepancies between the RIC UAC drawing and what is actually being manufactured. He volunteered to provide the TC with recommended changes for the next revision of the standard. AGENDA ITEM 8; UPCOMING MEETINGS The next TC meeting is scheduled for 23-24 May, 2017, in Virginia Beach, VA. No other meetings are scheduled for 2017. AGENDA ITEM 9; ADJOURNMENT MOTION BY CLINT MAYHUE; SECOND BY ROBIN GAINEY To adjourn. MOTION CARRIED. Chairman Rossos adjourned the meeting at 15:40 on 18 January 2017. Respectfully submitted, Steven H. Weinstein, Secretary Technical Committee on Respiratory Protection Equipment Page 3 of 3

Public Comment No. 23 NFPA 1852 2017 [ Global Input ] This standard should apply to all compressed air, liquid air, and supercritical air. Whenever compressed air is listed, liquid air and supercritical air should be included. Liquid air is air that has been cooled to below the condensation temperature for its pressure. It is typically stored at a pressure slightly above atmospheric, for example between 30 and 75 psig. The storage vessel has in it a volume of liquid and a volume of vaporized gas above the liquid. Supercritical air is similar to liquid air, but does not have discrete liquid and gas phases. It is considered a homogeneous phase. Supercritical air must be maintained at about 750 psig. The advantages of using supercritical air in an SCBA include accurate remaining air measurement technology and natural attitude independence. That is, no matter what orientation the container is in, the air supply is not affected, similar to compressed air cylinders. This standard should apply to all compressed air, liquid air, and supercritical air. Liquid air should be included as a source of breathable air in a Self Contained Breathing Apparatus. When vaporized, this air is no different than compressed air. Supercritical air should be included as a source of breathable air in a Self Contained Breathing Apparatus. When expanded to near atmospheric pressure and room temperature, this air is no different than compressed air or air vaporized from liquid air. PI Submitter Full Name: Ed Roscioli Organization: ChemBio Shelter Inc Affilliation: ChemBio Shelter Inc Submittal Date: Mon May 08 15:46:24 EDT 2017 http://submittals.nfpa.org/terraviewweb/viewerpage.jsp 1/25

Public Comment No. 9 NFPA 1852 2017 [ Section No. 1.1.1 ] 1.1.1 * This standard shall specify minimum requirements for the selection, care, and maintenance of open circuit self contained breathing apparatus (SCBA) and combination SCBA/supplied air respirator (SAR) that are used for respiratory protection during emergency operations, tactical or technical operations in environments where the atmosphere is Immediately Dangerous to Life and Health (IDLH), or could become oxygen deficient or IDLH. Relevance to NFPA 1986. Relevance to NFPA 1986 Submittal Date: Wed Mar 29 14:20:36 EDT 2017 http://submittals.nfpa.org/terraviewweb/viewerpage.jsp 2/25

Public Comment No. 2 NFPA 1852 2017 [ Section No. 1.2.2 ] 1.2.2 This standard shall also establish basic criteria for the evaluation and selection process associated with purchasing open circuit SCBA to assure only SCBA that meet the requirements of NFPA 1981 or NFPA 1986are 1986 are acquired for use by emergency services organizations. Editorial correction. Editorial correction Submittal Date: Wed Mar 29 10:39:36 EDT 2017 http://submittals.nfpa.org/terraviewweb/viewerpage.jsp 3/25

Public Comment No. 5 NFPA 1852 2017 [ Section No. 2.2 ] 2.2 NFPA Publications. National Fire Protection Association, 1 Batterymarch Park, Quincy, MA 02169 7471. NFPA 19B, Standard on Respiratory Protective Equipment for Firefighters, 1971 edition. NFPA 1500, Standard on Fire Department Occupational Safety and Health Program, 2013 edition. NFPA 1901, Standard for Automotive Fire Apparatus, 2009 edition. NFPA 1981, Standard on Open Circuit Self Contained Breathing Apparatus (SCBA) for Emergency Services, 2018 edition. NFPA 1981, Standard on Open Circuit Self Contained Breathing Apparatus (SCBA) for Emergency Services, 2013 edition. NFPA 1981, Standard on Open Circuit Self Contained Breathing Apparatus (SCBA) for Emergency Services, 2007 edition. NFPA 1981, Standard on Open Circuit Self Contained Breathing Apparatus for Fire and Emergency Services, 2002 edition. NFPA 1981, Standard on Open Circuit Self Contained Breathing Apparatus for the Fire Service, 1997 edition. NFPA 1981, Standard on Open Circuit Self Contained Breathing Apparatus for Fire Fighters, 1992 edition. NFPA 1981, Standard on Open Circuit Self Contained Breathing Apparatus for Fire Fighters, 1987 edition. NFPA 1981, Standard on Open Circuit Self Contained Breathing Apparatus for Fire Fighters, 1981 edition. NFPA 1982, Standard on Personal Alert Safety Systems (PASS), 2013 edition. NFPA 1986, Standard on Respiratory Protection Equipment for Tactical and Technical and Tactical Operations, 2017 edition. NFPA 1989, Standard on Breathing Air Quality for Emergency Services Respiratory Protection, 2013 edition. Editorial correction. Editorial correction http://submittals.nfpa.org/terraviewweb/viewerpage.jsp 4/25

Submittal Date: Wed Mar 29 11:11:13 EDT 2017 Public Comment No. 3 NFPA 1852 2017 [ Section No. 4.4.3 ] 4.4.3 * SCBA certified to previous editions of NFPA 1981 shall be permitted to be upgraded to be compliant with the 2018 edition of NFPA 1981 in accordance with the SCBA manufacturer's and certification organization's instructions. The added text is necessary to preclude an SCBA certified to NFPA 1986 being able to be upgraded to NFPA 1981, 2018 Edition. NFPA 1986 relevance Submittal Date: Wed Mar 29 10:57:58 EDT 2017 http://submittals.nfpa.org/terraviewweb/viewerpage.jsp 5/25

Public Comment No. 10 NFPA 1852 2017 [ Section No. 4.7.3 ] 4.7.3 Defective or obsolete SCBA components or defective or obsolete SCBA that have been removed from service and cannot be repaired or upgraded shall be destroyed or altered in a manner assuring that they cannot be used in any emergency operations, tactical or technical operations or other activities, including training; or the ownership of such SCBA shall be transferred to the manufacturer or the manufacturer s agent. Relevance to NFPA 1986. Relevance to NFPA 1986 Submittal Date: Wed Mar 29 14:26:50 EDT 2017 http://submittals.nfpa.org/terraviewweb/viewerpage.jsp 6/25

Public Comment No. 4 NFPA 1852 2017 [ Section No. 5.1.2 [Excluding any Sub Sections] ] The organization shall review the following standards as a minimum: (1) NFPA 1981, Standard on Open Circuit Self Contained Breathing Apparatus (SCBA) for Emergency Services (2) NFPA 1982, Standard on Personal Alert Safety Systems (PASS), where SCBA integrated PASS are being considered as an accessory for the SCBA (3) NFPA 1986, Standard on Respiratory Protection Equipment for Tactical and Technical and Tactical Operations Editorial correction. Editorial correction Submittal Date: Wed Mar 29 11:09:24 EDT 2017 http://submittals.nfpa.org/terraviewweb/viewerpage.jsp 7/25

Public Comment No. 6 NFPA 1852 2017 [ Section No. 5.1.5 ] http://submittals.nfpa.org/terraviewweb/viewerpage.jsp 8/25

5.1.5 http://submittals.nfpa.org/terraviewweb/viewerpage.jsp 9/25

The organization shall consider at least the following items during the selection process: (1) Cross contamination between users and ease of cleaning/decontamination (2) Legibility of remote pressure indicators in reduced visibility (3) Size (4) Weight (5) Rated service time (6) Breathing resistance (7) Environment (8) Ease of donning and doffing (9) Comfort (10) Fit range and available number of facepiece sizes (11) Number and complexity of steps involved in operation and maintenance of the SCBA (12) Design features that provide positive feedback to the user that required steps have been completed properly (13) Design features that prevent steps from being performed improperly (14) Operability by user wearing the protective clothing and gloves worn when using SCBA (15) Facepiece vision area (16) Cylinder fill station requirements (17)* Method for uniquely identifying the components of the SCBA (18)* Facepiece nose cup (19) Vision correction needs of their personnel (20) Characteristics of the end of service time indicators (21) Communication capability including, but not limited to, speech diaphragms, voice amplifiers, radio interface) (22) Supplied air compatibility (23) Number of spare SCBA and cylinders (24) Rapid cylinder filling options (25) Cylinder types (26) Chemical, biological, radiological, and nuclear (CBRN) respiratory protection (27) SCBA accessories as follows: (28) Telemetry and monitoring systems (29) Personnel location systems (30) SCBA integrated PASS (31) Emergency egress escape systems for bailout (32) Emergency breathing safety system (EBSS) (33) Data log information and ease of retrieval (34) Battery life (35) Integration with command, accountability, and air management systems (36) Interface with certified CBRN ensembles http://submittals.nfpa.org/terraviewweb/viewerpage.jsp 10/25

(37) Interface with transportation seating (38) Interface with storage mechanisms (39) Interface or certification with fall protection harnesss (40) Interface or certification with escape or rappelling devices (41) Profile passing through openings (42) For SCBA certified to NFPA 1986, the following items: (a) Interface and mobility with weapons (b) Interface with body armor and non firefighting helmets (c) Interface with other tools and equipment not used in firefighting operations (d) Interface with cooling systems Relevance to NFPA 1986 and additional items for NFPA 1981 Relevance to NFPA 1986 Submittal Date: Wed Mar 29 11:19:58 EDT 2017 http://submittals.nfpa.org/terraviewweb/viewerpage.jsp 11/25

Public Comment No. 7 NFPA 1852 2017 [ Section No. 5.1.8 ] 5.1.8 Where the organization develops purchase specifications, at least the following criteria shall be considered: (1) All requirements developed by the organization in its evaluations conducted as specified in 5.1.3 through 5.1.7 (2) * Quantitative fit testing (3) User training (4) Maintenance training (5) Manufacturer assistance to develop SOPs for maintenance (6) SCBA testing on site prior to acceptance (7) Maintenance schedule (8) Complete parts list (9) SCBA user and service manuals (10) List of any specialized equipment or special tools needed for SCBA maintenance (11) List of authorized service centers (12) Warranty statement (13) Need for an optional EBSS (14) Need for an optional Supplementary Voice Communications System (15) Procedures for returning items found defective upon initial receipt (16) For SCBA certified to NFPA 1986, the following items: (a) Need for an optional HUD (b) Need for an optional RIC UAC Relevance to NFPA 1986, plus additional information for NFPA 1981 Relevance to NFPA 1986 http://submittals.nfpa.org/terraviewweb/viewerpage.jsp 12/25

Submittal Date: Wed Mar 29 12:11:55 EDT 2017 Public Comment No. 8 NFPA 1852 2017 [ Section No. 7.1.2.10 ] 7.1.2.10 Where SCBA has other required components (NFPA 1981) or optional components (NFPA 1982 or 1986), including rapid intervention company/crew universal air connection (RIC UAC), headsup display (HUD), PASS device, electronic communications enhancement, and any other required components not otherwise addressed herein, such components shall be inspected in accordance with the manufacturers' instructions and shall include at least inspection for signs of complete assembly of the component, wear, damage, secure attachment, adequate power source, and proper operation and functioning in accordance with the manufacturers' operational instructions. Relevance to NFPA 1986 and NFPA 1982 Relevance to NFPA 1986 Submittal Date: Wed Mar 29 12:29:07 EDT 2017 http://submittals.nfpa.org/terraviewweb/viewerpage.jsp 13/25

Public Comment No. 11 NFPA 1852 2017 [ Sections A.1.1.1, A.3.2.1 ] Sections A.1.1.1, A.3.2.1 A.1.1.1 Emergency operations where respiratory protection is needed from IDLH atmospheres includes but is not limited to confined spaces, hazardous materials releases, chemical, biological, radiological, nuclear (CBRN) incidents, fire fighting, tactical or technical operations, medical treatment, technical rescue, any operations where the atmosphere is not stable or improving and could become IDLH, and any operations where it is difficult or not possible to accurately monitor the atmosphere. A.3.2.1 Approved. The National Fire Protection Association does not approve, inspect, or certify any installations, procedures, equipment, or materials; nor does it approve or evaluate testing laboratories. In determining the acceptability of installations, procedures, equipment, or materials, the authority having jurisdiction may base acceptance on compliance with NFPA or other appropriate standards. In the absence of such standards, said authority may require evidence of proper installation, procedure, or use. The authority having jurisdiction may also refer to the listings or labeling practices of an organization that is concerned with product evaluations and is thus in a position to determine compliance with appropriate standards for the current production of listed items. Relevance to NFPA 1986. Relevance to NFPA 1986 Submittal Date: Wed Mar 29 14:30:18 EDT 2017 http://submittals.nfpa.org/terraviewweb/viewerpage.jsp 14/25

Public Comment No. 12 NFPA 1852 2017 [ Section No. A.3.3.3 ] A.3.3.3 Combination SCBA/SAR. Combination SCBA/SAR consist of the following: (1) An SCBA certified as compliant with NFPA 1981, Standard on Open Circuit Self Contained Breathing Apparatus (SCBA) for Emergency Services, and having a minimum rated service time of 30 minutes or an SCBA certified as compliant with NFPA 1986, Standard on Respiratory Protection Equipment for Tactical and Technical Operati o ns (2) A connection for the attachment of an air line that provides a continuous supply of breathing air that is independent of the SCBA breathing air supply The definition does not include SAR that are used in conjunction with escape self contained breathing apparatus (ESCBA) where ESCBA provide less than a minimum rated service life of 30 minutes. For the purposes of this standard, combination SCBA/SAR are encompassed by the terms self contained breathing apparatus and SCBA. Relevance to NFPA 1986 Relevance to NFPA 1986 Submittal Date: Wed Mar 29 14:33:14 EDT 2017 http://submittals.nfpa.org/terraviewweb/viewerpage.jsp 15/25

Public Comment No. 13 NFPA 1852 2017 [ Section No. A.3.3.9 ] A.3.3.9 Organization. Examples of such organizations include, but are not limited to, fire departments, police and other law enforcement agencies, rescue squads, EMS providers, military and defense agencies, and hazardous materials response teams. Relevance to NFPA 1986 Relevance to NFPA 1986 Submittal Date: Wed Mar 29 16:09:35 EDT 2017 http://submittals.nfpa.org/terraviewweb/viewerpage.jsp 16/25

Public Comment No. 14 NFPA 1852 2017 [ Section No. A.4.3.7 ] A.4.3.7 The SCBA manufacturer should be contacted prior to any after purchase modifications of any sort to an SCBA. Unapproved modifications could affect the NIOSH certification or certification to NFPA 1981 or NFPA 1986 and void the certifications. Relevance to NFPA 1986. Relevance to NFPA 1986 Submittal Date: Wed Mar 29 16:13:17 EDT 2017 http://submittals.nfpa.org/terraviewweb/viewerpage.jsp 17/25

Public Comment No. 15 NFPA 1852 2017 [ Section No. A.4.7.5 ] A.4.7.5 No specific requalification procedures are outlined in 49 CFR for composite cylinders. Therefore, the Department of Transportation (DOT) developed certifications known as special permits (previously known as exemptions). DOT authorized composite cylinders have a maximum service life indicated in the exemption special permits. Most exemptions special permits specify that composite cylinders have a maximum life of 15 years, although some 30 year special pemits are available. The composite cylinder is prohibited from being refilled after 15 years from the original hydrostatic test date the maximum life specified in the special permit. All U.S. retest facilities performing requalifications on composite cylinders are required by the DOT to have a current copy of the cylinder's exemption available the cylinder's special permit available, and have to follow its instructions and conditions. The DOT, which is the regulatory authority in the United States, specifies the cylinder requalification frequency of every 3 years for fiberglass or Kevlar composite cylinders and the cylinder requalification frequency of every 5 years for all metal cylinders and carbon fiber composite cylinders. The organization/cylinder owner and retest facility are required by the DOT to know how often to have the requalification performed. (See also Annex C.) Brings the information up to date for 30 year cylinders and carbon cylinders. Corrects old information Submittal Date: Wed Mar 29 16:23:11 EDT 2017 http://submittals.nfpa.org/terraviewweb/viewerpage.jsp 18/25

Public Comment No. 16 NFPA 1852 2017 [ Section No. A.7.1.1.1 ] A.7.1.1.1 A For fire departments, a duty period should include, but not be limited to, a single shift in a career department, a substitute person taking over a position for part or all of a shift, personnel assigned to station duty in a department where the station is not staffed on a 24 hour daily basis, and other similar situations. Differentiating between fire service and non fire service users. Relevance to NFPA 1986 Submittal Date: Wed Mar 29 16:45:16 EDT 2017 http://submittals.nfpa.org/terraviewweb/viewerpage.jsp 19/25

Public Comment No. 17 NFPA 1852 2017 [ Section No. A.7.2.4.5 ] A.7.2.4.5 No specific design or requalification procedures are outlined in 49 CFR for composite cylinders. Therefore, the DOT developed certifications known as special permits (previously known as exemptions). DOT authorized composite cylinders have a maximum service life indicated in the exemption. Most exemptions specify that composite cylinders have a maximum life of 15 years. The composite cylinder is prohibited from being refilled after 15 years from the original hydrostatic test date. All U.S. retest facilities performing requalifications on composite cylinders are required by DOT to have a current copy of the cylinder's exemption available and to follow its instructions and conditions. DOT, which is the regulatory authority in the United States, specifies the cylinder requalification frequency for all cylinders. The organization/cylinder owner and retest facility are required by DOT to know how often to have the requalification performed. (See also Annex C.) See A.4.7.5. Duplication of A.4.7.5. Duplication of previous item Submittal Date: Wed Mar 29 16:52:23 EDT 2017 http://submittals.nfpa.org/terraviewweb/viewerpage.jsp 20/25

Public Comment No. 18 NFPA 1852 2017 [ Section No. A.7.3.5 ] A.7.3.5 During emergency operations and training, cylinders should be filled in accordance with the SCBA manufacturers instructions and NIOSH approved fill methods for the specific cylinder. Fire departments should also review the requirements in Section 7.15 of NFPA 1500. Relevance to NFPA 1986. Relevance to NFPA 1986 Submittal Date: Wed Mar 29 16:54:38 EDT 2017 http://submittals.nfpa.org/terraviewweb/viewerpage.jsp 21/25

Public Comment No. 20 NFPA 1852 2017 [ Section No. C.2 ] C.2 Exemptions Special Permits (formerly known as Exemptions). No specific requalification procedures are outlined in 49 CFR for composite cylinders. Therefore, the DOT developed certifications known as special permits (previously known as exemptions). C.2.1 All composite cylinders authorized for sale and use in the United States have a DOT special permit number (previously known as an exemption number). This is what is meant by DOTauthorized. Information on special permits is found in 49 CFR. C.2.2 DOT special permitted cylinders are requalified according to specific conditions and frequency written in the exemption. All U.S. retest facilities performing requalifications on composite cylinders are required by DOT to have a current copy of the cylinder's special permit available and have to follow its instructions and conditions. The organization/cylinder owner and retest facility are required by DOT to know how often to have the requalification performed. Editorial correction. Editorial correction Submittal Date: Wed Mar 29 16:59:28 EDT 2017 http://submittals.nfpa.org/terraviewweb/viewerpage.jsp 22/25

Public Comment No. 19 NFPA 1852 2017 [ Section No. C.2.2 ] C.2.2 DOT special permitted cylinders are requalified according to specific conditions and frequency written in the exemption special permit. All U.S. retest facilities performing requalifications on composite cylinders are required by DOT to have a current copy of the cylinder's special permit available and have to follow its instructions and conditions. The organization/cylinder owner and retest facility are required by DOT to know how often to have the requalification performed. Editorial correction. Editorial correction Submittal Date: Wed Mar 29 16:57:40 EDT 2017 http://submittals.nfpa.org/terraviewweb/viewerpage.jsp 23/25

Public Comment No. 21 NFPA 1852 2017 [ Section No. D.1.1 ] D.1.1 NFPA Publications. National Fire Protection Association, 1 Batterymarch Park, Quincy, MA 02169 7471. NFPA 19B, Standard on Respiratory Protective Equipment for Firefighters, 1971 edition. NFPA 1500, Standard on Fire Department Occupational Safety and Health Program, 2013 edition. NFPA 1981, Standard on Open Circuit Self Contained Breathing Apparatus (SCBA) for Emergency Services, 2018 edition. NFPA 1981, Standard on Open Circuit Self Contained Breathing Apparatus (SCBA) for Emergency Services, 2013 edition. NFPA 1981, Standard on Open Circuit Self Contained Breathing Apparatus (SCBA) for Emergency Services, 2007 edition. NFPA 1981, Standard on Open Circuit Self Contained Breathing Apparatus for the Fire Service, 1997 edition. NFPA 1981, Standard on Open Circuit Self Contained Breathing Apparatus for Fire Fighters, 1992 edition. NFPA 1981, Standard on Open Circuit Self Contained Breathing Apparatus for Fire Fighters, 1987 edition. NFPA 1981, Standard on Open Circuit Self Contained Breathing Apparatus for Fire Fighters, 1981 edition. NFPA 1986, Standard on Respiratory Protection Equipment for Tactical and Technical Operations, 2017 edition. Relevance to NFPA 1986. Relevance to NFPA 1986 Submittal Date: Wed Mar 29 17:03:55 EDT 2017 http://submittals.nfpa.org/terraviewweb/viewerpage.jsp 24/25

Public Comment No. 22 NFPA 1852 2017 [ New Section after D.2.3 ] International Training Incorporated Informational resources I would like to offer another reference material which covers high pressure cylinders; steel aluminum and composite cylinders. It also reviews the compressors used by the fire service to fill these cylinders. Visual Inspections Procedures manual International Training Incorporated 1321 SE Decker Ave, Stuart FL, 34994 Don Kinney Author Inspection training, inspection equipment, inspection certification, ISO organization adding another source of information when dealing with the inspection of high pressure cylinders, specifically composite cylinders, assists the member with additional knowledge. The visual inspection manual covers all cylinders used in the fire industry, including fire suppression and reviews the use of compressors for filling the cylinders. This organization, and manual, give the technician more knowledge in a very limited field. International training complies with NFPA standards and is a registered ISO member complying with their rigorous oversight. SCBA cylinders Cylinder inspections Submitter Full Name: Don Kinney Organization: Cylinder Training Services Affilliation: International Training Incorporated Submittal Date: Tue Apr 18 12:44:50 EDT 2017 http://submittals.nfpa.org/terraviewweb/viewerpage.jsp 25/25

Public Comment No. 2 NFPA 1989 2017 [ Global Input ] This standard should apply to all compressed air, liquid air, and supercritical air. Whenever compressed air and liquid air are listed, supercritical air should be included. Supercritical air is similar to liquid air, but does not have discrete liquid and gas phases. It is considered a homogeneous phase. Supercritical air must be maintained at about 750 psi. The advantages of using supercritical air in an SCBA include accurate remaining air measurement and natural attitude independence. That is, no matter what orientation the container is in, the air supply is not affected, similar to compressed air cylinders. Supercritical air should be included as a source of breathable air in a Self Contained Breathing Apparatus. When expanded to near atmospheric pressure and room temperature, this air is no different than compressed air or air vaporized from liquid air. PI Submitter Full Name: Ed Roscioli Organization: ChemBio Shelter Inc Affilliation: ChemBio Shelter Inc Submittal Date: Mon May 08 12:41:15 EDT 2017 http://submittals.nfpa.org/terraviewweb/viewerpage.jsp 1/2

Public Comment No. 1 NFPA 1989 2017 [ Chapter B ] Annex B Informational References (Reserved) resource: Visual Inspections Procedures Student manual International Training Incorporated 1321 SE Decker Ave Stuart, Florida 34994 Author: Don Kinney Currently there are a limited number of resources for compressor maintenance and operation. The listed publication covers basic compressor maintenance as well as logs for air fills and compressor maintenance logs. The manual helps the NFPA member to stay in compliance with NFPA standard 1989. compressor operations compressor maintenance Submitter Full Name: Don Kinney Organization: Cylinder Training Services Affilliation: International Training Incorporated Submittal Date: Tue Apr 18 13:33:59 EDT 2017 http://submittals.nfpa.org/terraviewweb/viewerpage.jsp 2/2