Solution F2. Fire Alarm Control Panels one step ahead.

Similar documents
Solution F1. Fire Control Panels the new generation

Intelligent addressable fire alarm control panel

The system is expanded via the RCC network with each RCC capable of passing information to and from up to 31 detection or output devices.

The EN54 Part 2 & 4 Fire System

The EN54 Part 2, 4 and 13 Fire System

Discovery 1-4 Loop 32 Zone, 40 Character Analogue Addressable Control Panel. Application Guide

Voice Alarm. Multifunctional Voice Alarm Systems. certified to EN54

Analogue addressable devices

Different types of Fire Alarm System

Discovery 1-4 Loop 96 Zone, 40-Character Analogue Addressable Control Panel. Application Guide

ZXe INTELLIGENT MULTI PROTOCOL FIRE ALARM CONTROL PANEL

ZXSe Range. Fire Safety. Analogue addressable fire alarm control panel KEY FEATURES. Panel Features

ZXSe Range Data Sheet

XP95/Series 90 Test Set

Overview. Wireless Overview QLD NSW VIC Fundamentals. Operation. Features.

Advanced FireAlarm Panel 1-4Loop

Reliably Advanced Extinguishing Control

Fire and Gas Monitoring Panel ST7-HV

Sita200plus. 200detectors. Single loop analogue addressable System

designed for rail 5000 Series

Consultant Specification AGILE Wireless Fire Detection System

STANDARD TECHNICAL SPECIFICATION FOR AN ANALOGUE ADDRESSABLE FIRE DETECTION SYSTEM

APPLICATION NOTE. Document Type. Application Note. Document Title. Date January Version DS0167/Iss 2. ESP Technical Summary

On the job around the clock 24/7: Fire detection systems

Fire control panel detect 3004 plus and accessories

ACP10 & ACP50 Security Systems

CODESEC FIRE ALARM SYSTEMS. security technologies

Touch Screen 1 loop Addressable Fire Alarm Panel

YOUR PARTNER IN FIRE & GAS DETECTION

Evolution Analogue Addressable Fire System

Intelligent 2 & 4 Loop Fire Alarm Control Panels

System 800 Addressable Fire Detection & Alarm System

The ID51 & ID52 can be upgraded to 2 loops without the need to change back box. FEATURES. Intelligent Features

Intelligent Single Loop Fire Alarm Control Panel

PANELS, KEYPADS & MODULES. Take Fire Protection to the Next Level Fire Products from DSC

IQ8Control C Fire Alarm Panel

Protec. Protec Algo-Tec TM 6500 Interactive Digital Addressable Fire Control System with Algo-Tec 6600 Bridging Network. Fire Detection - Addressable

Fire Product Catalog

Wireless Fire & Security Solutions. Fire Product Showcase

Intelligent Addressable Fire Alarm System

4100S. The operation and functions described in this manual are available from Software Version 4100S onwards.

Fire Detection Systems Product Catalogue (Version )

Addressable and Conventional Fire Protection

GE Security. FP1200, FP2000 and KSA1200 series fire panels, repeaters and emulators Interconnection and wiring

Who we are? - Nº 1 Spanish fire alarm systems manufacturer years experience in the fire detection field countries worldwide.

Protec. Protec Algo-Tec TM 6100 Interactive Digital Addressable Fire Control System. Fire Detection - Addressable

IGD.CO.UK

FIRElux Emergency Lighting

Security Alarm Systems

Apollo Accreditation. Need further information? Visit

Protec. Protec Algo-Tec TM 6500 Open Protocol Interactive Digital Addressable Fire Control System with Algo-Tec 6600 Bridging Network

Reliably Advanced Extinguishing Control

DATA SHEET CYBERCAT 254 INTELLIGENT FIRE ALARM CONTROL SYSTEM DESCRIPTION APPROVALS: SYSTEM OPERATION. Form No. D

Fire Detection - Addressable

For Complete Fire and Gas Solutions

HART XL High Sensitivity Smoke Detection

MINERVA. Marine. Fire Detection. MX T2000 Panel Range. Features: MINERVA Marine Panel Range

Siemens aspirating smoke detector (ASD) for the addressed FDnet/C-NET detector line or for standalone operation

The Kentec driver connects to the Kentec Syncro range of fire detection panels. Available for Commander and ObSys.

Fire control panels FC726 FC726-XA

Added password for IP setup page : Password must be in IP format!

561-MB256 plus. Intruder alarm control panel. Performance features

Protec. Protec Algo-Tec TM 6100 Interactive Digital Addressable Fire Control System. Fire Detection - Addressable

FULL REDUNDANT RING BUS FIRE DETECTION SYSTEMS FOR RAILWAY APPLICATIONS: EN 54-2, EN (VdS) Reducing False Alarms

Product Catalogue. Intelligent Control Equipment for Life Safety. Issue 1

ZIOU/230 - MAINS IO INSTRUCTION MANUAL

Fire-Cryer. Plus Application Guide APPLICATION GUIDE FIRE EXIT VIMPEX. Shaping Alarm Technology

Protec. Protec Algo-Tec TM 6100 Interactive Digital Addressable Fire Control System. Fire Detection - Addressable

REMOTE MONITORING AND ALARM SYSTEM

The technological shield of fire safety

Master devices. Type X-AIR-ZMAS. Zone master module for up to 25 zone modules, with integral webserver and interfaces to higher-level systems

INTRUDER ALARM SOLUTIONS PRODUCT LIST 2012

Fire. The menace advances. What s the next move? Play safe. Choose Inim. Space protected. Danger eliminated. Everything under control.

1) This manual covers 4400, 5400 and 6400 fire alarm systems. The differences are described in the appropriate sections.

Cerberus FIT conventional system

Our technology, your peace-of-mind. Product list

Fire alarm system EBL512 G3

FC330A-ECO Auto-addressing analogue 1-Loop fire detection panel

Quick Selection Guide Fire Systems LSN Periphery

IntelliKnight 5820XL Addressable Fire Alarm Control System Sales Guide

MX4428. Addressable Fire Alarm System. Features. Advantages & Options

Algo-Tec 6300 INTERACTIVE DIGITAL ADDRESSABLE FIRE CONTROL SYSTEM (1-4 LOOPS)

SI120 Guarto Easy I. Alarm system. Fire & Security Products

NU2 Smart Power Supply (SPS) Manual

ID50series. intelligent fire alarm panels

IC60 Sintony 60 Intrusion Control Panel

EXICALL EN70 EXICALL EN70MR EXICALL EN70-ATEX

Syncro AS. Analogue Addressable Fire Control Panel. User Manual

HART XL High Sensitivity Smoke Detection

FC700A Fire detection control unit

CHEETAH XI INTELLIGENT SUPPRESSION CONTROL SYSTEM

XP95 Sounder VAD Base

DATA SHEET CHEETAH XI 50 INTELLIGENT SUPPRESSION CONTROL SYSTEM DESCRIPTION APPROVALS: SYSTEM OPERATION. Form No. D

Conventional Fire Detection

Honeywell Air Sampling Devices Data Sheet

four Vigilon Compact Analogue Addressable Fire Detection & Alarm System 4/1

APPLICATION DATA SHEET

ADR Analog Addressable Fire Alarm Control Panel. Technical Manual. Control Panels. 3000En. En pdf

ANALOGUE ADDRESSABLE FIRE CONTROL PANELS FIREQUEST FAMILY. Section 6 Trouble Shooting Issue 1.1

The supplier and installer of the system should be approved by the local civil defence authority.

Transcription:

Solution F2 Fire Alarm Control Panels one step ahead. Sicherheitstechnik Sicherheitstechnik GmbH GmbH

The Fire Alarm Control Panel Solution F2 Solution F2 in B2 enclosure (B01090-00) The Concept The Solution F2 Fire Control Panel is a new generation, extendable and ultra modern Fire Control Panel for small applications. This has been developed to meet international standards and to satisfy specific international requirements at the highest level. A lot of experience and knowhow from the outstanding Solution F1 Fire Control Panels have influenced the development of this new Fire Control Panel. Flexibility especially for connecting different detectors was one of the most important aims during the development of this new Solution F2. Very remarkable: The Solution F2 panel is compatible to the newest analogue addressable sensors of Hochiki and Apollo two of the biggest and best known players in the detector market worldwide. The panel has as standard one loop module supporting 126 Apollo sensors or 127 Hochiki sensors plus 127 base sounders (only Hochiki), a power supply unit 230 VAC / 24 VDC with 2,5 or 3,5 Amps, a control panel with membrane keypad and graphics LCD module, USB and RS232 interface and several inputs and outputs. The following extension modules are available: A second loop module I/O interface (2 sounder outputs, 3 relay outputs etc.) RS485 interface card 64 Zone LEDs modules Depending on the configuration there is the choice of one of two sizes for the housing. The panel provides already as Solution F2 the key to more safety.

Solution F2 in A enclosure (B01070-00) standard a slot for an I-Module. That means an analogue or ISDN telephone modem can be plugged into the panel. By using the NSC configuration software the panel can be configured by remote access control. In addition, on the card location of the I-module the new NSC Web server can be plugged in. Then you have access to the Solution F2 panel via any common internet browser. Signal processing, indications and operating the panel are exactly according to the EN54 standard. All inputs and outputs are programmable. And for some more comfort there are soft keys below the LCD module and programmable push buttons for often used operating functions. Intelligent Single-Loop Panel with comprehensive possibilities to extend for small applications Designed according to EN54 standard, part 2 and 4; VdS and CPD approved Supports Hochiki ESP sensors and modules as well as the Apollo ranges XPlorer, XP95 and Discovery Integrated Control Panel including graphics LCD module and internal Power Supply Unit 24 V/2,5 or 3,5 A PC configuration by the well-known and easy-touse NSC configuration software (Windows XP.NET based) USB and RS232 interfaces included in the standard configuration Extension modules available for controlling of the German Fire Brigade Control Panel incl. transmission device, for RS485 interfaces User-friendly membrane keypad with programmable push buttons for user defined functions

The extension modules I/O Interface Card This module can be used as universal I/O module or as interface card for the Fire Brigade. It provides 3 programmable dry relay contacts, 2 programmable and monitored sounder outputs, 1 monitored input zone and 16 digital & programmable OC inputs/outputs. Loop module for second detector loop The second loop module supports also two protocols: Hochiki ESP sensors as well as all addressable Apollo sensors. In case of the ESP detectors 127 sensors/modules plus 127 base sounders are supported. In case of Apollo 126 sensors, modules and loop sounders are supported. The maximum cable length is 3.500 m. RS485 Interface card The RS485 interface card provides two separate useful RS485 interfaces. So these can be used to connect building management systems (BMS) or LCD repeater panels. If you are using them as a redundant RS485 interface the German Fire Brigade LCD Repeater Panel (FAT) can be connected according to DIN 14662. The protocol and the baud rate are programmable by the Solution F2 software. NSC Webserver Module Permits the access to NSC Fire Control Panels via the Internet without special software Use of the www infrastructure => e.g. by means of Internet Explorer, Firefox, Safari etc. User administration for 30 users Technical specifications: Quiescent current: 38 ma (24 V DC) Linux O/S Software with 2.6.24 kernel 10/100 Mbps Ethernet LAN interface ARM9 CPU 192 MH 32 MB SDRAM 32 MB NOR Flash 3.3 V/ 300 ma Dimensions: 56 x 56 x 20 mm Access by user name and password 9 different access authorizations Indicates all messages/status of the FCP Shows the complete event log Online control of the Fire Alarm Panel front facia Complete operation of the FCP Plug-in module

Manual Call Points, Loop Modules, Sounder/Beacons n Manual Call Points are available in two different versions: in a bigger enclosure for the German market and in a small enclosure n They comply with the European standard EN54, part 11, and have international approvals n Loop Modules are available as input modules, output modules and combined n The modules are either mountable on a DIN rail or in an attractive surface mounted housing n All modules can be ordered with integrated isolators and they are VdS approved n The new base sounder provides 51 different tones and 10 different volumes (max. output 98 db) n On one loop 127 sensors/modules plus 127 base sounders are supported; as a matter of course this system is VdS-approved n The base sounders can either be mounted onto a standard base or onto an isolator base n In case of using detectors on top of the base sounder the base will be automatically addressed by the panel n As an option the base sounder is available with integrated LED beacon n The wall mounted loop sounder can be used for indoor applications (IP 42 rated) or with an optional weatherproof kit for outdoor applications (IP 65 rated) n All the loop sounders distinguish themselves by a very low current consumption; typical 2 ma at 90 db(a). Software Configuration software for Solution F1 and F2 panels Windows Explorer based software and so it is very easy and fast to handle Implemented by Windows.NET For configuration of detectors, zones, inputs, outputs, loops and spurs For analysing of analogue values / cable resistors / statistics / event memory Drag- and drop functionalities For use with analogue or ISDN modem as well

Compatible analogue addressable detectors The Hochiki ESP detector range Optical smoke detector ALN-EN with Flat Response Technology Photoelectric smoke detector which is fully compatible to the Hochiki ESP protocol. The ESP protocol is immune to noise and other communication problems such as loop cross-talk and data corruptions The ALN-EN incorporates Hochiki s unique Flat Response Technology removing the need to use Ionisation Sensors in the majority of applications and this also allows the sensor threshold level to be increased, thereby improving the signal to noise ratio and reducing susceptibility to false alarms. 254 detectors / modules can be controlled per loop. In addition each address can support up to 16 sub-addresses. Automatic drift compensation. Sensitivity selection by software configuration of Fire Control Panel Solution F1. Low power mode in case of mains AC fault. Detector address is electronically stored in a non-volatile memory within the sensor. Twin fire alarm LEDs give 360 viewing in case of alarm condition. Detector test by Solution F1 software VdS approval no. G 21 30 82 / 0832-CPD-2163 Multi Sensor ACC-EN with Flat Response and Dual Channel Technology Multi Sensor which is fully compatible to the Hochiki ESP protocol. The ESP protocol is immune to noise and other communication problems such as loop cross-talk and data corruptions Several detection modes / algorithm programmable by the Solution F2 Fire Control Panel (Photoelectric smoke sensor, heat sensor, combined sensor) and can be combined with timed cause and effects events. The ACC-EN incorporates Hochiki s unique Flat Response Technology removing the need to use Ionisation Sensors in the majority of applications and this also allows the sensor threshold level to be increased, thereby improving the signal to noise ratio and reducing susceptibility to false alarms. lncorporates high performance optical sensor as well as two heat sensors (Adjustable rate of rise sensor and adjustable fixed temperature sensor). Other features like photoelectric smoke detector above. VdS approval no. G 21 30 80 / 0832-CPD-2161 Analogue addressable Heat Sensor ATJ-EN Heat detector which is fully compatible to the Hochiki ESP protocol. The ESP protocol is immune to noise and other communication problems such as loop cross-talk and data corruptions Fixed temperature detector and rate of rise detector according EN-54, part 5, with accurate temperature measurement. Sensitivity selection by software configuration of Fire Control Panel Solution F1. Other features like photoelectric smoke detector above. VdS approval no. G 21 30 81 / 0832-CPD-2162

The Apollo range XP95 / Discovery Analogue addressable Optical smoke detectors type XP95 / Discovery The Solution F2 Fire Control Panel supports 100% Apollo s protocols XP95 and Discovery. Automatic drift compensation. Sensitivity selection by software configuration of Fire Control Panel Solution F2. 126 sensors / modules per loop can be controlled by the panel software. Addressing by unique XPERT cards. All detectors VdS and CPD approved. Analogue addressable Multi- Sensor type XP95 / Discovery Multi-Sensor comprises optical smoke and thermistor temperature sensors whose outputs are combined to give the final analogue value. Other features like optical smoke sensor above. Analogue addressable Heat Sensor type XP95 / Discovery Heat Sensor which has a thermistor element to measure exactly the surrounding air temperature. Distinguishable by the low airflow resistant case. Other features like optical smoke sensor above. Addressable Manual Call Points ABS housing with integrated alarm LED. With interrupt mode for quick alarm response. Manual call point address is electronically stored in a non-volatile memory. In-built dual isolator

Typical loop configuration All addressable devices loop powered Duct Probe SDP-2 B03400-00 Multi Sensor ACC-EN, B02011-00 Multi Heat ATJ-EN, B02021-00 Addressable Remote Indicator B04101-00 MCP B02320-00 Input / Output modules, DIN Rail Smoke Detector ALN-EN, B02002-00 Imput / Output modules, IP54, Surface mounted FCP Solution F2 Remote Indicator, programmable, B04106-00 Analogue Output Module 2-32 ma, B02415-00 I.S. Smoke Detector B05300-00 I.S. Heat Detector B05310-00 I.S. Barrier B05340-00 Stratos ASD incl. APIC B05101-00 24 V DC Addressable Beam Detector, B05540-00 Loop Beacon B07270-00 Wall Sounder B07160-00 Base Sounder Beacon, B07153-00 Base Sounder B07151-00 Addressable PSU B01622-01 Technical specifications Ordering information Supply voltage: Output voltage: 230V AC +10 / -15%, 50/60 Hz 24 V DC Power supply: 2,5 A (Housing A) / 3,5 A (Housing B) Quiescent current consumption: Operating temperature: 101 ma (24 V DC) -5 C +40 C Battery charging: 24 V / 12 Ah (Housing A) 24 V / 24 Ah (Housing B) Humidity: Max. 95 % Loops: Loop current: Detector cablel: Protocols: 1 (standard), (2 = Option) max. 450 ma per loop JY-(ST)Y 2 x 2 x 0,8 / max. 3.500 m Hochiki ESP / Apollo XP95, Discovery Detectors + sounders per loop: Hochiki: 127 + 127 / Apollo: 126 Graphics LCD module: Event log: Relay outputs: Open collector outputs: Monitored power outputs: Dimensions housing A (B x H x T): Dimensions housing B (B x H x T): 240 x 64 dots 10,000 messages 3 x, max. 30 V DC / 1 A (standard) 8 x, max. 30 V DC / 60 ma 2 x 24 V DC / max. 500 ma 340 x 320 x 125 mm 500 x 380 x 170 mm VdS approval: VdS G 208 145 0786-CPD-20670 EN54-13 VdS S 205 024 Description Part no. Fire Control Panel Solution F2 incl. 1 loop in housing A B01070-00 Fire Control Panel Solution F2 incl. 1 loop in housing B1 B01080-00 Fire Control Panel Solution F2 incl. 1 loop in housing B2 B01090-00 PCB for zone indication by LED B01220-00 Loop module for second loop B01100-00 I/O Interface B01110-00 RS485 Interface card B01115-00 Relay card with 8 change over contacts B01330-00 Analogue telephone modem module for configuration software B01370-00 ISDN telephone modem module for configuration software B01373-00 Configuration software B01395-00 Webserver Module B01380-00 Lange Wand 3 n D-33719 Bielefeld Fon +49 (0) 5 21.136 29-0 Fax +49 (0) 5 21.136 29-29 info@nsc-sicherheit.de www.nsc-sicherheit.de Fire Alarms Voice Evacuation Systems CCTV