½ Monitored Pneumatic Valve Patented Technology

Similar documents
½ Monitored Pneumatic Valves On Series Ported Manifold

Monitored Pneumatic Valves On Series Ported Manifold

Pressure Switches Precautions 1 Be sure to read this before handling.

Multistage Ejector MODEL / Series / Product Number

SMHA Hatch High temperature fan HT-fan Installation and Maintenance

KITCHEN EXHAUST FAN GLEC-6 INSTALLATION AND MAINTENANCE

Operating instructions Safety-monitoring module SRB 302X3. 1 About this document

Refrigerated Air Dryer

Refrigerated Air Dryer

Warning Caution. Safety Precautions (Be sure to read these precautions before using our products.)

! WARNING. Before using product, read and understand instructions.

ORIGA-SENSOFLEX Displacement Measuring System for Cylinder Series OSP-P

R32. Installation Manual Split Type Wall Mounted Air Conditioner. This appliance shall be installed in accordance with: REFRIGERANT

High Output Vacuum/Pressure Pump

Refrigerated Air Dryer

Operating instructions Safety-monitoring module SRB 302X3. 1. About this document. Content

Condensate drains WA/PWEA

Aquamax KF Oil Evaporator. User Manual

GLEB Kitchen exhaust fan

MANUAL. Dryspell INSTALLATION OPERATION MAINTENANCE. Regenerative Type Heatless Desiccant Dryer

Vacuum system component SELVACS

M/1700; 5/2 & 5/3 Solenoid and pilot actuated spool valves

5 m pre-wired 2NC/1NO F3S-TGR-NLMX m pre-wired 2NC/1NO F3S-TGR-NLMX m pre-wired 2NC/1NO F3S-TGR-NBMX-21-05

Instruction Manual Dry spell HFH INSTALLATION, OPERATION, MAINTENANCE. Regenerative Type Heatless Desiccant Dryer

Instruction Manual, Toftejorg Rotary Spray Heads Toftejorg MultiMidget, Toftejorg MultiMagnum

Table of Content

GLEB. >> Installation and Maintenance. Air Comfort. Air movement. Duct & Box Fans

Handling or using the product improperly and in disregard of the instructions with this mark might result in serious bodily injury or death.

Reducing Valve Direct Mount Type with Pressure Gauge. Direct Mount Type (Compact size) Pressure Gauge is selectable.

Air Filter. Filter for Removing Dust and Drain in Compressed Air. Filter for Drain and Dust (Filtering Accuracy: 5µm)

ISCG90SS _03 ISCG90SS

Doc. No. IZ -OMK0015 OPERATION MANUAL PRODUCT NAME: MODEL:

PS-2/ES Automated pack & tag machine with IndES fastening system

Air Filter. Filter for Removing Dust and Drain in Compressed Air. Filter for Drain and Dust (Filtering Accuracy: 5µm)

AP-EH500-L/RQA9837. Installation Guide

KEEP FOR FUTURE REFERENCE 1 SCFM NOMINAL AIRFLOW SINGLE VACUUM SYSTEM DC-VOLTAGE POWER SYSTEM WITH MANUAL VALVE

Instruction Manual, Rotary Spray Heads

OK, OKA, OKAF; ELD; ELDM; ELH; OKC; SC; SCA; SCAF; OK-LN; OKA-LN; OKAF-LN.

SensaGuard TM Integrated Latch Installation Instructions

30GH Air-Cooled Liquid Chillers 30GH Nominal cooling capacity kw

! WARNING. Before using product, read and understand instructions.

VRA2000 Series Port size: Rc1/4, Rc3/8, G1/4, G3/4, 1/4NPT, 3/8NPT

Prevents condensation

TEMPERATURE CONTROLLERS

CENTRIFLOW 3D. >> Installation and Maintenance. air comfort. CentriFlow 3D

Use and maintenance Manual Longitudinal profile welding Model: LRW-130

Vacuum unit ideal for controlling large flow rates Vacuum unit VSQ/VSQP series

No.THD51E To prevent accidents arising from the use of this product, please ensure the operator using it receives this manual.

CRU 200 and 500 Series Condensate Recovery Unit Installation and Maintenance Instructions

Designed for testing three-phase circuits up to 600V Install on line or load side of electrical disconnect Detects absence of AC and DC voltage

BHW INSTALLATION, OPERATION AND MAINTENANCE MANUAL MEDIUM STATIC PRESSURE DUCTABLE TYPE. Models:

Operation and Maintenance Manual

Operating Instructions. Boilermag XL Filter. High Intensity Magnetic Separator

Operating Guide Safe Torque Off

XB-EFA-8L-BK & XB-EFA-8R-BK

ISIS SAFETY SYSTEM Installation guide

Steam Trap BK 45 BK 45-U BK 45-LT BK 46

ULTRA LOW TEMPERATURE FREEZER. User Manual

LONGONI ENGINEERING SRL

Remote Air Cooled Condensers C2 Series

OPERATING MANUAL ORWAK March 2005 PUBL. NO Edition 4

! WARNING. Before using product, read and understand instructions.

SAFETY AND OPERATING MANUAL. All-in-One blower/ vac/mulcher WG502E

Vacuum suction nozzle OVEM-...-1P/1N

Original instructions Sense7-series Non-contact coded safety switch

INLINE СENTRIFUGAL FAN BOX BOX-R OPERATION MANUAL

Air. Pressure. Motion. nnnnnnnn

SYSTEM MANUAL Description


THERMAL SYSTEMS, INC. Installation and Operation Manual

FSW300 Series Flow Switch

Important Safety Notice

SAFETY AND OPERATING MANUAL

RTK Instruments Limited St James Business Park, Knaresborough, North Yorkshire, England. HG5 8PJ

Document No. IZ*-OMP0064 C. P r o d u c t Ionizer. Model/Series. IZS4 Series

Instructions for the fan motor control system, SILVER C

Edition 8 From serial no Publ. no OM 5030NHD; Orwak 5030-NHD OPERATING INSTRUCTIONS (IN THE ORIGINAL)

CRU-S Series Stainless Steel Condensate Recovery Unit

Universal Gripper UG 16, UG 18. Operating Instructions

Operating Manual. VIENNA Hot Display

Natural Ventilation. e-stack A-Series Ventilation System for Buildings with Atria. Installation and Maintenance. Palletised

Risk assessment and analysis for swing gates

RFID Non-contact switches are designed to monitor hinged, sliding or removable guard doors. RFID technology provides increased tamper resistance.

Product Data Sheet Adsorption Dryer DPS (A)

1. Description INSTRUCTION FOR BLAST COOLER TYPE COOL 250. Material

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 21 to 39 kw

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw

EXHAUST PURGE DESICCANT AIR DRYER INSTRUCTION & MAINTENANCE MANUAL MODEL RE-231 THROUGH RE-252

Installer: (Name, address, telephone number)

NRG NRG NRG NRG

ORIGINAL INSTRUCTIONS

Product Data Sheet Refrigerant Dryer DFLO-ES 66 (-W) to DFLO-ES 660 (-W) with energy saving management

Filter for Drain and Dust (Filtering Accuracy: 5µm) Optional Selection of Direct Mount Pressure Gauge (Compact size).

M7100 Pressure Transducer

Original instructions INCA-1 Emergency stop for enclosure installation INCA-1S Safety stop for enclosure installation

INSTALLATION GUIDE NZ AU D

CP-200 S&T. CP Warewash Pump Instruction & Operation Manual Speed & Time , Rev1.0, , Page 1 of 8

Installer: (Name, address, telephone)

1. Description INSTRUCTION FOR AIR BLAST COOLER TYPE COOL 450

Operating Guide Safe Torque Off

Transcription:

½ Monitored Pneumatic Valve Patented Technology PBM4-S (Valve only air service equipment not included) SUITABLE FOR RISK CATEGORY 4 APPLICATIONS As per AS4024.1-Part 1502 & 1502 SIL 3 as per IEC 61508 & EN ISO 13849-1 Applications Include: Pneumatic Presses Palletising Equipment Pneumatic Pushers & Ejectors Pneumatic Guillotines Packaging Machinery Guard Access Preconditions Automated Fixtures Robot & Automated Cells Pneumatic Strapping Machines Fluidsentry Pty Ltd PO Box 8135 (1 / 32-34 Frankston Gardens Drive) Carrum Downs Victoria 3201 Australia Ph: +61 (0) 3 9776 4352 - Fax: +61 (0) 3 9776 4372 E-mail: sales@fluidsentry.com www.fluidsentry.com

Fluidsentry VALVE SPECIFICATIONS May 2013 Description: Directional control valves for pneumatic safety applications in sliding spool type with static seals, configured for three port two position operation. Each valve incorporates a two-pole positive opening plunger type switch with positive opening contact. The model offered has certification to meet Australian & European machinery safety standards. The valve is 24VDC as standard. Model: Dual series ported valves PBM4-S (Suitable for Risk Category 4 applications) Materials: Main body, extension housing: Aluminium Pilot housing: Plastic Spool: Aluminium Return spring: Zinc Plated Steel Seals: Nitrile rubber Screws: Cap Screws Lubricant: Silicon Grease Switch: Make: Bernstein Model: C2-U1Z (6008101001) Type: Plunger Approvals: EN 1088, EN 60947-5-1, EN 292, EN 60204-1 Contacts: 1 x Normally Closed (Safety Contact) 1 x Normally Open (Non Safe Contact) Wiring: Switch Terminals: 11-12 White Black (NC), 21-22 Brown blue (NO) Coil: Voltages available: 24vdc Power Consumption DC: 2W Features: Blue LED and surge suppression Allowable Voltage: -15% to + 10% Rated Voltage Performance: Valve working pressure range: 250 1000 kpa Port connection: ½ BSP Medium: Compressed air filtered to 5 micron and/or lubricated Operating temperature range: Max +50 Celsius Cv (flow factor) P to A 3.7 Maximum Operating Frequency: 5Hz Activation time: 19 Milliseconds Deactivation time: 65 Milliseconds Rating: Protection: IP 67 Approvals: Low Voltage Directive: File No: R 9250033 EMC Directive: File No: H/EMC 95000251-3 Machinery Directives: 98/37/EC EN 292-1, EN 292-2, EN 983, EN 954-1, EN 1050 Manual: Manual Override: Not Available Silencers: Pilot Exhaust: 1/8 BSP SMC Part No: AN101-01 Main Exhaust: 1/2 BSP SMC Part No: AN40-04

PBM4-F-N-P-S Wiring J1 Brown Blue Black White J2 (Note: Cable For J2 Plug Optional. Not Supplied With Valve) Brown Blue Black White J3 Black White Brown Blue J1 J3 J2 PNEUMATIC FUNCTION CAUTION IMPORTANT: The above drawings are a conceptual example and are intended for guidance purposes only. They have not been specifically drawn in relation to your plant. Failing to ensure professional installation of Fluidsentry equipment which has regard to the specific circuit design and operation of the plant on which it is being installed may create a safety hazard. Accordingly Fluidsentry is not liable for loss or injury, whether direct or indirect, resulting from the incorrect installation of this product.

DECLARATION OF CONFORMITY Valves manufactured by FLUIDSENTRY Pty Ltd conform to the requirements of the following European and Australian Standards. Low Voltage Directive: 73/23/EEC EN 60204, IEC 1010, IEC 950. EMC Directive: 89/336/EEC EN 55014, EN 50081-2, EN 50082-1, EN 50082-2 Machinery Directive: 98/37/EC EN 292-1, EN 292-2, EN 983, BS EN60204 EN ISO 13849 Date: 14th April, 2013 MTTFd - 30 Years Note: The products must be used in accordance with the installation instructions and operating conditions in the relevant data sheet, which has been produced to support the requirements of the harmonised standard EN ISO 13849. Additionally, for products intended to be sold in European Economic Area: Safety devices or other safety functions mentioned in any product literature are not necessarily safety components as defined by the Machinery Directive 2006/42/EC, unless otherwise stated together with the CE Mark and specific reference to said directive. AUSTRALIAN STANDARDS- AS4024.1 Part 1501 Design of Safety Related Parts of Control Systems General Principles Part 1502 - Design of Safety Related Parts of Control Systems Validation Fluidsentry herewith declares that the supplied Fluidsentry model of: VALVE: MODEL - PBM4-S (Dual Valve System) TYPE: DUAL MONITORED PNEUMATIC Comply with all applicable Directives and Harmonized Standards for Pneumatic Fluid Power Systems and their components and are qualified to bear the CE mark. Melbourne Australia 14 th April 2013. FLUIDSENTRY ACN 109 094 975 P.O.Box 8135 Carrum Downs Vic 3201 AUSTRALIA. Phone:+61 (0)3 9776 4352 Fax:+61 (0)3 9776 4372 Email: sales@fluidsentry.com Murray Andrew Hodges Name and signature of Authorized person. Valve Serial No.. Tested.../.../..

90 43 35 98.5 141.5 PBM4-S Dual Valve System Dimensions

Safety Instructions These safety instructions are general in nature, and intended to prevent hazardous situations and/or equipment damage. These instructions indicate the level of potential hazard by labeling Caution or Danger. To ensure safety, be sure to observe ISO4414 Note 1, JIS B 8370 Note 2 and other safety practices. The person who designs the pneumatic system or decides its specification must also refer to the specific Safety Instructions supplied for individual components which can be found in each Product Series brochure. Caution: : Danger: Operator error could result in injury or equipment damage. Operator error could result in serious injury or loss of life. In extreme conditions, there is a possibility if serious injury or loss of life. 1. The compatibility of pneumatic equipment s the responsibility of the person who designs the pneumatic system or decides its specifications. Since the products specified here are used in various operating conditions, their compatibility with the specific pneumatic system must be based on specifications or after analysis and/or tests to meet your specific requirements. 2. Only trained personnel should operate pneumatically operated machinery and equipment. Compressed air can be dangerous if an operator is unfamiliar with it. Assembly, handling or repair or pneumatic systems should be performed by trained and experienced operators. 3. Do not service machinery/equipment or attempt to remove components until safety is confirmed. 1. Inspection and maintenance of machinery/equipment should only be performed after confirmation of safe locked-out control positions. 2. When equipment is to be removed, confirm the safety process as mentioned above. Cut the supply pressure for the equipment and exhaust all residual compressed air in the system. 3. Before machinery/equipment is re-started, take measures to prevent quick extensions of the cylinder piston rod etc.(bleed air into the system gradually to create back pressure) 4. Contact Fluidsentry if the product is to be used in any of the following conditions: 1. Conditions and environments beyond the given specifications, or if product is used outdoors. 2. An application which has the possibility of having negative effects on people, property, or animals, requiring special safety analysis. Note 1) ISO4414: Pneumatic fluid power Recommendations for the application of equipment to transmission and control systems. Note 2) JIS B 8370: Pneumatic systems axiom.

Precautions May 2013 Selection 1. Confirm specifications Products represented in this catalogue are designed for use in compressed air applications only, unless otherwise indicated. Do not use the products outside their design parameters. Installation 1. Do not install unless the safety instructions have been read and understood. Keep this catalogue on file for future reference. 2. Maintenance When installing the products, please allow access for maintenance. 3. Tightening Torque When installing the products, please follow the listed torque specifications Piping Caution 1. Before Piping Make sure that all debris, cutting oil, dust, etc. are removed from the piping. 2. Sealant Tape When installing piping or fitting into a port, ensure that sealant material does not clog up the pressure port. When using sealant tape, leave the first 1.5 to 2 thread turns exposed at the end of the pipe/fitting. Air Supply 1. Operation fluid Compressed Air 2. Install an air dryer, aftercooler etc. Excessive condensate in a compressed air system may cause valves and other pneumatic equipment to malfunction. Installation of an air dryer, after cooler, etc. is recommended. 3. Drain If condensate in the drain bowl is not emptied on a regular basis, the bowl will overflow and allow the condensate to enter the compressed air lines. If the drain is difficult to check and remove, it is recommended that a drain bowl with the autodrain option be installed. 4. Use clean air If the compressed air supply is contaminated with chemicals, synthetic materials, corrosive gas, etc., damage to the pneumatic equipment may occur. Environment 1. Do not use in an environment where the product is directly exposed to corrosive gases, chemicals, salt water, water or steam. 2. Do not expose the product to direct sunlight for an extended period of time. If the product has to be mounted in an area where exposure to direct sunlight cannot be avoided, the use of a protective cover is recommended. 3. Do not mount the product in a location where it is subject to strong vibrations and/or shock. 4. Do not mount the product in a location where it is exposed to radiant heat Maintenance 1. Maintenance If handled improperly, compressed air can be dangerous. Assembly, handling and repair of pneumatic systems should be performed by qualified personnel only. 2. Drain Remove condensate from the filter bowl on a regular basis. 3. Shut-down before maintenance Before attempting any kind of maintenance make sure the supply pressure is shut off and all residual air pressure is released from the system to be worked on. 4. Start-up after maintenance Apply operating pressure and power to the equipment and check for proper operation and possible air leaks. If operation is abnormal, please verify product set-up parameters. 5. Do not make any modification to the product 6. Do not take the product apart