OUTDOOR DRINKING FOUNTAINS OPERATIONS MANUAL

Similar documents
LIVIN THE DOG LIFE DRINKING FOUNTAINS INSTALLATION & OPERATION MANUAL

Installation & Operation Manual

Installation & Operation Manual

Installation & Operation Manual

Installation & Operation Manual

Cooler Mounted Bottle Fillers

A112408B/S-VR-UBL TECHNICAL ASSISTANCE TOLL FREE TELEPHONE NUMBER: Technical Assistance Fax:

INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS

Model 1011/1011HPS Drinking Fountain

Model H1011.8/H1011.8HPS Water Cooler

Models: FM FM WARNING

A152.8 Series Barrier Free, Bi-Level, Wall Mounted Drinking Fountain

A910.8A Remote Water Chiller, 8 GPH A A / A A-220V TECHNICAL ASSISTANCE TOLL FREE TELEPHONE NUMBER:

INSTALLATION, OPERATIONS & MAINTENANCE MANUAL A171.8 Series Barrier Free, Wall Mounted Water Cooler

A132.8 Series Barrier Free, Wall Mounted Electric Drinking Fountain

INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS Sensor Operated AquaAccess Barrier Free, Wall Mounted Water Cooler

A171.8-VR & VRB Series Barrier Free, Vandal Resistant & Resistance Button, Wall Mounted Water Cooler

Cooler Mounted Bottle Fillers

PAT BASIN MODEL 9121, 9131, & 9141

MERIDIAN MODEL# 3793

INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS Refrigerated Bi-Level, Sensor Operated, AquaAccess Barrier Free, Wall Mounted Water Cooler

Installation Instructions for. WaterMaster Series Fountains

INSTALLATION INSTRUCTIONS

Installation Instructions / Warranty

INSTALLATION INSTRUCTIONS

TRU-TEMP VALVE. Tru-Temp Pressure Balance 1/2" Rough-In Valve Owner's Manual 3001-RIV-PB-ORB 3001-RIV-PB-BN 3001-RIV-PB-CH 3003-RIV-PB-ORB

? Teflon Tape? 9/16 Fixture Wall Anchors and. ? 9/32 Fixture Wall Anchors and

Installation Instructions for. WaterMaster Series Fountains

PL-004-SS. * Proper water pressure is required for simultaneous operations

Installation IMPORTANT! Bradley Multi-Station Wall Sink

A171.8 Series Barrier Free, Wall Mounted Water Cooler

Installation Instructions / Warranty. PuraVida 15775XX1

Installation Instructions / Warranty

PD-811 PD-811 propriétaire Owner s manual Manuel du PD D P

SEABREEZE. SeaBreeze Rain Shower System Model #1086-CH Owner's Manual

3121FR Pedestal Mounted Drinking Fountain

Installation and Maintenance Instructions

Installation, Operation and Maintenance Guide AP3900 Series Thermostatic Mixing Valves

MEGATRON MODEL 2, 3, 4, and 5

INSTALLATION INSTRUCTIONS

Installation LC800. Patient Care Unit, 47", Fixed Water Closet. Table of Contents

Installation Instructions for. DairyFount Series Fountains

1.6 GALLON ONE PIECE TOILET

INSTALLATION 125 PSI (8.6 BAR) MAXIMUM OPERATING PRESSURE

INSTALLATION 125 PSI (8.6 BAR) MAXIMUM OPERATING PRESSURE

Decor Star 1. Decor Star PL-037-SS

Model /8300CRP-8309CRP Shower & Eye/Face Wash

1/7 INSTALLATION INSTRUCTIONS. Rough Installation

Installation Instructions

Features Decor Star PL-004-SS

Installation Instructions / Warranty

INSTALLATION, OPERATIONS & MAINTENANCE MANUAL

Ligature Resistant. ADA Compliant

INSTALLATION 125 PSI (8.6 BAR) MAXIMUM OPERATING PRESSURE

Note: Please provide valve serial number (stamped on cover of valve) when ordering parts. Tempered Water Outlet. Hot Water Inlet.

A172108F-UBL / A172408F-UBL / A172108F-SO / A172408F-SO TECHNICAL ASSISTANCE TOLL FREE TELEPHONE NUMBER:

INSTALLATION 125 PSI (8.6 BAR) MAXIMUM OPERATING PRESSURE

Features Luxier SP21-SS

Installation Instructions / Warranty. Massaud

Model 8330 Stainless Steel Combination Shower Eye/Face Wash

FFP S700 SERIES. Pull-Out Spray Faucet. Installation guide

Installation and Use Manual

Installation LC840. Patient Care Unit, 40", Fixed Water Closet. Table of Contents

COVER PLATE GREY PLASTIC OR OPTIONAL SOLID BRASS DIAL

Model 8300FP Freeze Resistant Combination Shower Eye/Face Wash

TECHNICAL ASSISTANCE TOLL FREE TELEPHONE NUMBER TECHNICAL ASSISTANCE FAX:

DISCONTINUED. Widespread Lavatory Faucet TL170DD RENESSE. Contents. Installation and Owner s Manual. English Español Français

Reserve Exposed Thermostatic Valve Installation Instructions

Model 1900 Retrofit Bottle Filler

INSTALLATION ADJUSTMENT SERVICE THERMOSTATIC WATER MIXING VALVE SERIES LV-981 & LV-982

INSTALLATION ADJUSTMENT SERVICE HIGHLOW THERMOSTATIC WATER MIXING VALVE SERIES XL-32, XL-82

Installation Instructions / Warranty

H Barrier-Free Wall Mounted Electric Drinking Fountain

Single Handle Lavatory Faucet

H Barrier-Free Wall Mounted Electric Drinking Fountain

INSTALLATION 125 PSI (8.6 BAR) MAXIMUM OPERATING PRESSURE

Features Decor Star PL-004-SS

Installation Instructions / Warranty

PLEASE READ THIS MANUAL BEFORE USING YOUR APPLIANCE. KEEP THIS MANUAL IN A SAFE PLACE FOR FUTURE REFERENCE.

Installation Instructions / Warranty. Hansgrohe Single Control Kitchen Mixers

Features Luxier SP21-SS

INSTALLATION SETUP AND OPERATING INSTRUCTIONS THERMOSTATIC WATER MIXING VALVE SYSTEM TM-500, TM-550

Installation CRS-2/IR, CRS-3/IR WARNING IMPORTANT. Table of Contents. Express Crescent Lavatory System CRS-Series

Terreon Lav Decks WARNING

Installation Instructions / Warranty. Metris 31060XX XX XX1

Note: Please provide valve serial number (stamped on cover of valve) when ordering parts. Thermometer. Hot Water Inlet. Cold Water Inlet G3600LF

INSTALLATION ADJUSTMENT SERVICE

OUTLET HOT INLET COLD INLET INSTALLATION

Series Barrier-Free Water Coolers

FREELANCE ORDERING INFORMATION NOTES T01-D

WINE AND BAR SERIES. Sink Installation Kit. For assistance, call ; for UK ; at

Nachi Series TM Z6957-XL

ODEON BEFORE YOU BEGIN ORDERING INFORMATION T01-C , 2006 Copyright Kohler China Ltd.,

Installation LD3060. OmniDeck Series. Table of Contents Rev. R; ECM Bradley Corporation Page 1 of 10 3/30/11

Installation Instructions for. OmniFount

Installation Instructions

Installation, Operation and Maintenance Guide G3600 Series Thermostatic Mixing Valves

Model Combination Shower Eye/Face Wash

Owner s Manual. Pelican Custom Premium WHWF 1354/1665

Series Barrier-Free Water Coolers

Transcription:

OUTDOOR DRINKING FOUNTAINS OPERATIONS MANUAL

Installation & Operation Manual Stainless Steel Series One-, Two-, and Three-station Outdoor Drinking Fountains MADE IN THE U.S.A. Table of Contents Pre-Installation Information Standard Fountain Confi gurations Physical Dimensions Rough-in Dimensions Required Installation Supplies Parts List and Exploded-view Drawings Hardware Identifi cation Installation Instructions Step 1: Fixture Installation Step 2: Adjusting Drinking Spout Flow Care and Maintenance Troubleshooting Drinking Fountain Drawings Physical Dimensions Rough-in Dimensions Pushbutton Details Warranty Winterization Commercial Outdoor Drinking Water Fountains as offered by:

Outdoor Drinking Fountains Pre-Installation Information Installation & Operation Manual Installation notice! Check Rough-In location PRIOR to installation Flush lines thoroughly PRIOR to hook-up Before step 1 of the installation instructions, ensure that rough-ins are in the correct location. The valve assembly, including the spray head, MUST NOT BE connected until after all lines have been fl ushed to remove the small particles of debris that are inherent with new construction projects and all chemicals that are used in fl ushing are purged from the system. Chemicals used in fl ushing plumbing systems can attack the internal components of the valve and spray head and severely damage them, so any fl ushing of the system must be followed by a full fl ushing with pure water to clear any harsh chemicals remaining in the system. Debris in the system if allowed to enter the valve assembly and spray head can cause poor performance or outright failure. Again DO NOT attempt to connect the valve assembly and spray head until after all flushing is complete and pure water is the only media that will be passing through the system. Damage to the valve assembly or spray head caused by harsh chemicals or debris will not be covered by the manufacturer's warranty. Any fi ttings provided by the installer should be made of plastic to electrically isolate the unit from the building or connected plumbing system. The grounding of electric equipment such as telephones, computers, etc, to water lines is a common procedure. This grounding can cause electrical feedback into a water fountain or similar fi xture, causing electrolysis, which results in a metallic taste or an increase in the metal content of the water. This can easily be avoided by using the proper materials as indicated. Installation notice! Check Rough-In location PRIOR to installation Flush lines thoroughly PRIOR to hook-up

Outdoor Drinking Fountains Installation & Operation Manual Adult Adult - Child Adult - ADA 2000 Adult - Child - Dog 3000-ADA Adult - ADA - Child We offer several varieties and models of commercial outdoor drinking fountains - please tell us your specifications and we can help supply you with the appropriate fountain per your projects request.

Outdoor Drinking Fountains Physical Dimensions- Installation & Operation Manual * YELOW 14-1/2" 4X 9/16" THRU ALL 12-1/2" BOLT CIRCLE 600601HE BUBBLER 600315 RECESSED PUSHBUTTON 8-1/2" X 14" ACCESS COVER W/ SECURITY SCREWS 35" C 40" 42-1/2" 6" 10-3/4"

Outdoor Drinking Fountains Rough-in Dimensions Installation & Operation Manual * DRAIN CONNECTION 1-1/2" SCHED. 40 PVC 12-1/2" BOLT CIRCLE 4X 9/16" THRU ALL WATER SUPPLY CONNECTION 3/8" TUBING (LOCATION IS FLEXIBLE) VALVE ASSEMBLY DETAIL #600315 VALVE ASS'Y 1/4" TUBE NOTE: UNIT MUST BE DISCONNECTED AND DRAINED DURING WINTERIZATION, PER THE FOLLOWING RECOMMENDED PRACTICES: SHUT OFF WATER SUPPLY TO FIXTURE (SUPPLY STOP AND WATER LINES BY OTHERS) DISCONNECT AND REMOVE IN-LINE FILTER PRESS AND HOLD PUSHBUTTON FOR 10 SECONDS TO ALLOW WATER LINES TO DRAIN #980632 INLINE STRAINER 1/4" TO 3/8" PRESS LOCK NOTE: 3/8" O.D. SUPPLY CONNECTION 1-1/2" PVC COUPLING 12" A.F.F. 11-13/16" A.F.F. SERVICE SHUT-OFF VALVE (BY OTHERS) CONCRETE ANCHORS 4X 1/2"-13 UNC X 4" CONCRETE PAD WATER SUPPLY LINE OPEN HUB DRAIN TO BE 1-1/2" IPS MINIMUM TO A POROUS GRAVEL FILL OR MAIN SEWER LINE LOCATED BELOW FROST LINE

Outdoor Drinking Fountains Installation & Operation Manual Rough-in Dimensions- Series w/ Pet Fountain * 120.00 TYP. DRAIN CONNECTION 1-1/2" SCHED. 40 PVC WATER SUPPLY CONNECTION 3/8" TUBING (LOCATION IS FLEXIBLE) 6X 9/16" THRU 12-1/2" BOLT CIRCLE TYP. 14-3/4" VALVE ASSEMBLY DETAIL #600315 VALVE ASS'Y 1/4" TUBE NOTE: UNIT MUST BE DISCONNECTED AND DRAINED DURING WINTERIZATION, PER THE FOLLOWING RECOMMENDED PRACTICES: SHUT OFF WATER SUPPLY TO FIXTURE (SUPPLY STOP AND WATER LINES BY OTHERS) DISCONNECT AND REMOVE IN-LINE FILTER PRESS AND HOLD PUSHBUTTON FOR 10 SECONDS TO ALLOW WATER LINES TO DRAIN #980632 INLINE STRAINER 1/4" TO 3/8" PRESS LOCK NOTE: 3/8" O.D. SUPPLY CONNECTION CONCRETE ANCHORS 6X 1/2"-13 UNC X 4" 12" A.F.F. SERVICE SHUT-OFF VALVE (BY OTHERS) CONCRETE PAD OPEN HUB DRAIN TO BE 1-1/4" IPS MINIMUM TO A POROUS GRAVEL FILL OR MAIN SEWER LINE LOCATED BELOW FROST LINE WATER SUPPLY LINE

Outdoor Drinking Fountains Required Installation Supplies Installation & Operation Manual Proper mounting hardware Proper plastic fi ttings as indicated Hardware for waste oulet connections Gasket for waste outlet connection Shims (for installation if necessary) Supply piping Silicone caulk Plumbers putty

Outdoor Drinking Fountains Installation Instructions Step 1: Fixture Installation Installation & Operation Manual Note: the outdoor drinking fountain is to be mounted on a fl at, level surface (concrete or otherwise) with an adequate support structure. Note: refer to Rough-In Dimensions for locating plumbing connections. 1.) Install service shut-off valve in water supply line (valve not furnished). 2.) Locate and install drinking fountain using 1/2"-13 x 4" concrete anchors (anchors not furnished). 3.) As noted previously, fl ush the water supply line with clean drinking water before making fi nal connections to the drinking fountain. 4.) Connect water supply line to inline strainer inside drinking fountain using 3/8" plastic tubing (extra tubing not furnished). Push tube straight into fi tting on fi lter about 3/4" until it reaches a positive stop. Water supply connection must comply with local codes. 5.) Connect fountain drain line to drainage system. Drain is to be 1-1/2" IPS minimum to a porous gravel fl ll or main sewer line located below frost line. Installer to provide waste trap downstream of drain connection. Drain and waste trap must comply with local codes. 6.) Turn on water supply and check both the water supply lines and drain lines for leaks.

Outdoor Drinking Fountains Installation Instructions (cont.) Step 2: Adjusting Drinking Fountain Flow 1.) Insert a standard flat-head screwdriver into adjustment opening on face of pushbutton, as shown. Installation & Operation Manual 2.) Rotate screwdriver to adjust until desired fl ow is achieved: Rotate clockwise to increase fl ow. Rotate counterclockwise to decrease fl ow.

Outdoor Drinking Fountains Care and Maintenance Installation & Operation Manual Unit Care during Cold 'Freezing' Weather These fountains are resistant to freezing if proper winterization procedures are followed. Outdoor Drinking Fountains require Winterization maintenance protocol steps to be freeze resistant whcih consist of shutting off the water supply and draining of the water line above freeze points, please see instructions. The unit should be disconnected or shut off from the water supply and drained during the colder freezing months. We do offer FRV Freeze Resistant Valve options at additional costs, please see the details listed on the back pages. For more information, refer to the roughin detail. should be cleaned or replaced regularly. New inline s trainers can be ordered using Part No. 980632. Stainless Steel Care Stainless Steels are basically alloys of iron and chromium and are corrosion resistant. Stainless steel has a bright surface that is easy to clean and is free from oxides. Therefore, cleaning of stainless steel is relatively simple and easy if done on a regular basis. that fresh (soft) deposits of all kinds are relatively easy to remove, while removing older (hard) brush or cloth. Baking soda, borax or any of several non-abrasive commercial cleansing agents clean stainless steel. Such items will scratch the surface or leave small particles of iron imbedded in the surface, which will eventually rust and stain the surface - even appearing as if the stainless itself was rusting. allowed to stand for long periods of time, can pit the surface of even stainless. Products containing hydrochloric acid, muriatic acid or potassium hydrochloride can ruin the surface.

Outdoor Drinking Fountains Troubleshooting- Drinking Fountain Installation & Operation Manual INSUFFICIENT FLOW A. Ensure the service shut-off valve is fully open (provided by installer). B. Ensure water supply is within the normal operating range of 40-60 psi. 1. If pressure is too low, flow can be drastically reduced. 2. If pressure is too high, the strainer and/or valve may have been damaged. 3. The unit is rated for a maximum range of 30-105 psi. C. Inspect the unit's valve for damage, and replace if necessary. D. Inspect the inline strainer for damage and/or clogging, and clean or replace as necessary. E. Check all fi ttings and tubing for damage and leaks. Replace components as necessary. UNIT HAS PROBLEMS DRAINING A. Remove any debris from the drain. B. Remove any debris from the PVC pipe and fi ttings. C. Check and clear the waste trap (provided by installer).

DRAWING: Physical Dimensions 8-1/2" X 14" ACCESS COVER W/ SECURITY SCREWS 6" 14-1/2" 600601HE BUBBLER PUSHBUTTON 600315 RECESSED 10-3/4" 4X 9/16" THRU ALL 12-1/2" BOLT CIRCLE 40" 42-1/2" C 35"

DRAWING: Physical Dimensions 14-3/4" (1) 600601HE BUBBLERS (2) 600315 RECESSED PUSHBUTTONS 8 1/2" X 14" ACCESS COVER W/ SECURITY SCREWS 6" C 35" 12-1/2" BOLT CIRCLE TYP. 42-1/2" 39-15/16" 32" C E (1) 380056 BUBBLER 7" 10-3/4"

8-1/4" X 14" ACCESS COVER w/ SECURITY SCREWS 6" DRAWING: Physical Dimensions RED 14-1/2" 4X 9/16" THRU ALL 12-1/2" BOLT CIRCLE 50-15/16" (3) 600601HE BUBBLER (3) 600315 RECESSED PUSHBUTTONS 36-7/16" 33-15/16" 30-1/2" 27-1/2" CONCRETE PAD 10-3/4" (2) VANDAL RESISTANT S/S ACCESS PANEL 21-3/4" B 35" 30-11/16" 28-1/8" IN COMPLIANCE WITH A.D.A. 2010 42-1/2" 40" 24-3/4"

DRAWING: Rough-in Dimensions DRAIN CONNECTION 1-1/2" SCHED. 40 PVC WATER SUPPLY CONNECTION 3/8" TUBING (LOCATION IS FLEXIBLE) NOTE: UNIT MUST BE DISCONNECTED AND DRAINED DURING WINTERIZATION, PER THE FOLLOWING RECOMMENDED PRACTICES: SHUT OFF WATER SUPPLY TO FIXTURE (SUPPLY STOP AND WATER LINES BY OTHERS) DISCONNECT AND REMOVE IN-LINE FILTER PRESS AND HOLD PUSHBUTTON FOR 10 SECONDS TO ALLOW WATER LINES TO DRAIN 12" A.F.F. SERVICE SHUT-OFF VALVE (BY OTHERS) WATER SUPPLY LINE 12-1/2" BOLT CIRCLE 4X 9/16" THRU ALL VALVE ASSEMBLY DETAIL #600315 VALVE ASS'Y 1/4" TUBE #980632 INLINE STRAINER 1/4" TO 3/8" PRESS LOCK NOTE: 3/8" O.D. SUPPLY CONNECTION 1-1/2" PVC COUPLING 11-13/16" A.F.F. CONCRETE ANCHORS 4X 1/2"-13 UNC X 4" CONCRETE PAD OPEN HUB DRAIN TO BE 1-1/2" IPS MINIMUM TO A POROUS GRAVEL FILL OR MAIN SEWER LINE LOCATED BELOW FROST LINE

DRAWING: Rough-in Dimensions 120.00 TYP. DRAIN CONNECTION 1-1/2" SCHED. 40 PVC WATER SUPPLY CONNECTION 3/8" TUBING (LOCATION IS FLEXIBLE) 6X 9/16" THRU 12-1/2" BOLT CIRCLE TYP. 14-3/4" VALVE ASSEMBLY DETAIL #600315 VALVE ASS'Y 1/4" TUBE NOTE: UNIT MUST BE DISCONNECTED AND DRAINED DURING WINTERIZATION, PER THE FOLLOWING RECOMMENDED PRACTICES: SHUT OFF WATER SUPPLY TO FIXTURE (SUPPLY STOP AND WATER LINES BY OTHERS) DISCONNECT AND REMOVE IN-LINE FILTER PRESS AND HOLD PUSHBUTTON FOR 10 SECONDS TO ALLOW WATER LINES TO DRAIN #980632 INLINE STRAINER 1/4" TO 3/8" PRESS LOCK NOTE: 3/8" O.D. SUPPLY CONNECTION 12" A.F.F. CONCRETE ANCHORS 6X 1/2"-13 UNC X 4" SERVICE SHUT-OFF VALVE (BY OTHERS) CONCRETE PAD OPEN HUB DRAIN TO BE 1-1/4" IPS MINIMUM TO A POROUS GRAVEL FILL OR WATER SUPPLY LINE MAIN SEWER LINE LOCATED BELOW FROST LINE

DRAWING: Pushbutton Detail 1 5 2 3 6 4 ITEM # PART # DESCRIPTION QTY. 1 380110 PUSH PIN, ADJUSTABLE PUSHBUTTON VALVE 1 2 380111 SLEEVE, ADJUSTABLE PUSHBUTTON VALVE 1 3 800157 6-32 x 1/4" SH CAP SCREW 1 4 380062 SLEEVE, ADAPTER TO ELKAY PLASTIC SELF-CLOSING VALVE 1 5 600286 NUT, CARTRIDGE MOUNTING 1 6 600285 SELF-CLOSING CARTRIDGE, 1 GPM-LK 1 TITLE / DESC.: PART #: PUSHBUTTON VALVE ASSEMBLY, ADJUSTABLE 600315

Outdoor Drinking Fountains Warranty Installation & Operation Manual Manufacturer warrants to commercial and institutional purchasers only that each unit will be free from defects in workmanship and materials under normal use and service upon the following terms and conditions for a period of one (1) year from date of shipment. This warranty does not cover installation or any other labor charges and does not apply to any components damaged by accident, abuse, improper installation or improper maintenance. This warranty does not cover any installation that did not comply with national, state and local building, plumbing or electrical codes. The warranty is limited to replacing or repairing at manufacturer s option, transportation charges prepaid by the purchaser, any component or part which upon our inspection shall be deemed as defective within the limitations of this warranty. The replacement or repair of defective units as stated in this warranty shall constitute the sole remedy of the purchaser and the sole liability of Manufacturer. This warranty only extends to commercial and industrial purchasers and does not extend to any others, including consumer customers of commercial institutional purchasers. This warranty is in lieu of all other warranties, expressed or implied, including implied warranty of merchantability or

OPTIONAL FREEZE RESISTANT VALVE SPECS - ONE FAUCET

OPTIONAL FREEZE RESISTANT VALVE SPECS - TWO FAUCETS

OPTIONAL FREEZE RESISTANT VALVE SPECS - THREE FAUCETS