MINERVA MX. 800 Series Ancillary Equipment

Similar documents
Addressable Loop Modules

MINERVA. Marine. Fire Detection. MX T2000 Panel Range. Features: MINERVA Marine Panel Range

MINERVA MZX125 Digital Addressable Fire Detection System

MINERVA MZX125. Digital Addressable Fire Detection System

Intelligent Security & Fire Ltd

Installation, Operating and Maintenance Manual

AU MX Digital Loop Card Installation Instructions

Excel-EN Conventional Fire Control Panel

Specification/ Data Sheet

850 and 830 Series. Fire Detectors - Generation 6

The ID51 & ID52 can be upgraded to 2 loops without the need to change back box. FEATURES. Intelligent Features

830 Series. Fire Detectors - Generation 6

Certificate of Conformity Certificate num. Registration date Version Valid until

PNC 1000 SERIES 2, 4, 8 Zone Fire Alarm Control Panel

Conventional Fire Detection

ZXe INTELLIGENT MULTI PROTOCOL FIRE ALARM CONTROL PANEL

Application, Installation, Operation & Maintenance Manual

FIRE ALARM CONTROL EQUIPMENT. Addendum October 2006 Instructions for new style EN54-4 Power supply unit module

The EN54 Part 2 and 4 Fire System

System 800 Addressable Fire Detection & Alarm System

TECHNICAL DATA SHEET CONVENTIONAL FIRE ALARM SYSTEMS Conventional Fire Alarm Control Panel

ZIOU/230 - MAINS IO INSTRUCTION MANUAL

four Vigilon Compact Analogue Addressable Fire Detection & Alarm System 4/1

CCU Family of Modules

OPERATION AND INSTALLATION MANUAL

Interface and EOL Modules 8

Discovery 1-4 Loop 96 Zone, 40-Character Analogue Addressable Control Panel. Application Guide

(68.52) X. June 2000 supersedes February vigilon ADVANCED FIRE DETECTION & ALARM SYSTEMS

June 10, 2002 DF C S2424

Intelligent Security & Fire Ltd

The EN54 Part 2, 4 and 13 Fire System

The system is expanded via the RCC network with each RCC capable of passing information to and from up to 31 detection or output devices.

Intelligent addressable fire alarm control panel

On the job around the clock 24/7: Fire detection systems

LC1 & 2. Fire Alarm Panel 6\VWHPLQVWDOODWLRQRSHUDWLQJ PDLQWHQDQFH LQVWUXFWLRQV

The EN54 Part 2 & 4 Fire System

1200-HCM DIN RAIL MOUNTING FIRE SYSTEM MODULE Fire Detection & Extinguishant Control A R T PATOL LIMITED SUPPLY FAULT SOUNDER

Addressable and Conventional Fire Protection

EFBW series - BiWire Ultra control panel

INPUT / OUTPUT MINI MODULES

Reliably Advanced Extinguishing Control

GENERAL STANDARD FEATURES. ISO-9001 Engineering and Manufacturing Quality System Certified to International Standard ISO-9001 PATENT PENDING

Fire control panels FC360

Xenex Conventional Fire Detection & Alarm System

TECHNICAL DATA OBSOLETE

Sigma. K1000 Series 1, 2, 4 & 6 Zone Fire Control Panels. Operation and Maintenance Manual. Man-1048 Issue 05 October 2009

Reliably Advanced Extinguishing Control

Fire Alarm Control Panel. System Maintenance and Log Book

Discovery 1-4 Loop 32 Zone, 40 Character Analogue Addressable Control Panel. Application Guide

FDMM01S - FDMM02 - FDMM10- FDMM11S FDMM12 - Input / output mini modules

DYCU-3 AEROSOL FIRE EXTINGUISHER CONTROL UNIT OPERATION MANUAL

DATA SHEET CYBERCAT 254 INTELLIGENT FIRE ALARM CONTROL SYSTEM DESCRIPTION APPROVALS: SYSTEM OPERATION. Form No. D

CATALOGUE. Request to Exit Products Relays, Fuses & Timers TROJAN DEVELOPMENTS Product Catalogue.

Protec. Protec Algo-Tec TM 6500 Open Protocol Interactive Digital Addressable Fire Control System with Algo-Tec 6600 Bridging Network

July 14, 1999 DF C-100.

Sita200plus. 200detectors. Single loop analogue addressable System

ZXSe Range Data Sheet

USER MANUAL COMBINED FIRE & EXTINGUISHING CONTROL PANEL COMPLIES WITH BS EN PART 1 & EN54 PARTS 2 & 4

FireNET Plus Wiring Instructions

FTEN1, FTEN2, & FTEN4 1, 2 & 4 ZONE FIRE DETECTION AND ALARM CONTROL PANELS

FEC400 Series. Installation Manual

Control Panel Engineering and Commissioning Instructions

Protec. Protec Algo-Tec TM 6100 Interactive Digital Addressable Fire Control System. Fire Detection - Addressable

Fire control panel detect 3004 plus and accessories

ED820-24V MODEL INSTRUCTION MANUAL. fire DETECTOR

Installation and Operating Instructions

INDEX 1- Introduction The Control Pane...7l 4.1- The Control Panel 1 and 2 Loops The Control Panel 4 and 8 Loops...

AEGIS FEATURES DESCRIPTION. Conventional Fire Alarm-Suppression Control Unit. Effective: March Programmable Relays

Written by: A.C. Amended by G.G. Checked by: JBJ/PB Approved by:jbj

HS-5100, HS-5200, HS-5400 ANALOGUE ADDRESSABLE CONTROL PANELS. User Manual. Approved Document UI-ELAN-02 Revision 03

ZX1e ZX2e ZX5e. Document No Issue 01 user manual

FIREBETA EXTINGUISHING CONTROL PANEL (ECP)

SOLO Single Loop Addressable Fire Control Panel

Protec. Protec Algo-Tec TM 6500 Interactive Digital Addressable Fire Control System with Algo-Tec 6600 Bridging Network. Fire Detection - Addressable

SYSTEM MANUAL FT1-SB. Single Zone Fire Alarm System

Conventional Fire Alarm System Product Range Guide

SALES SUPPORT DOCUMENT

DUAL MONITORED INPUT/OUTPUT UNIT BN-305

ID50series. intelligent fire alarm panels

IGD.CO.UK

MS-4012/4024 and CMS-4012/4024. Instruction Manual for the. Fire Alarm Control Panels

Release Control Fire Alarm Systems

ORION Mini-Rep INSTALLATION MANUAL

Input/Output Modules Data Sheet

An introduction to... Sigma

Intelligent Security & Fire Ltd

Construction Products Regulation (CPR) Update. Graham Simons Technical Manager, FIA

CHEETAH XI INTELLIGENT SUPPRESSION CONTROL SYSTEM

Protec. Protec Algo-Tec TM 6100 Interactive Digital Addressable Fire Control System. Fire Detection - Addressable

Syncro AS. Analogue Addressable Fire Control Panel. User Manual

ACC-25/50ZST. Zoned System Voice with Telephone Evacuation Control Panel

Conventional Fire Alarm System 2014 V1.2

CONVENTIONAL >FIRE DETECTION C400 SYSTEM FIRE DETECTION

Installation Guide for AL800UL-ADA. NAC Power Extender. Rev

Vigilant MX4428 Fire Alarm System

C E R T I F I C AT LPCB I O N B O A R D P R E V E N T L O S S. Cooper Fire Systems

INTELLIGENT FIRE TECHNOLOGY. Twinflex and Multipoint V3. User Guide (TO BE RETAINED BY USER) Issue 3

Conventional Leaflets

FEC403EN Installation Manual

TECHNICAL DATA. Humidity: 85% Relative Humidity (non-condensing) at 90 F (32 C) maximum.

Transcription:

An extensive range of ancillary modules has been specifically designed for use with the MX range of Fire Controllers. The 800 range of ancillary modules provide the MX Fire Controller with a wide degree of systems application flexibility. This allows the field addressable loop from the control panel to both receive inputs to the system and control outputs from it. This broad range of modules allows the scope of the fire detection system to be significantly extended beyond a simple fire detector alarm sounder based alarm system. Features // Communication and control interface to MX Fire Controllers // High systems integrity // Allows remote sounder circuits // Allows loop powering of sounders // Monitoring of external equipment e.g. smoke dampers // Reduced installation costs // Removes the need for separate plant control circuits Safer. Smarter. Tyco. PSF127T.indd 1 13/12/2012 09:59:49

The command modules enable fire doors to be closed, fire dampers to be controlled, plus provide an interface to shut down HVAC and other plant control equipment. Other applications include an interface between shopping centre tenants premises and the landlords central control system. With the high systems integrity offered on the MX Controller the command modules can also be used to control a public address based building evacuation system. CIM800 Contact Input Module The CIM800 is a flexible addressable input-monitoring device that fits in the standard ancillary housings. The CIM800 provides a single input to current MX panels though this can be implemented as two separately wired spurs (Style B) or as a loop (Style A). Both spur and loop input wiring can be configured to monitor normally open or normally closed inputs. In addition both can be configured to initiate an alarm or short circuit fault message in the event of a short circuit on normally open monitoring circuits. DIM800 Detector Input Module The DIM800 is designed to power and monitor a circuit of low voltage conventional detectors and callpoints. The detection circuit is powered from an external 24V d.c. supply and is reset by the MX addressable panel. The DIM800 monitors the external 24V d.c. and provides a fault signal if it is lost. The input detection circuit can be wired as one or two spur circuits (Class B), one loop configured circuit (Class A) or one 4 wire detection circuit. The DIM800 is designed to be compatible with most conventional detection products. Compatibility has been tested to date on the following products: Compatible Thorn detectors: M300 Series, M600 Series, S100 Series, H Series, S231F, S231F+, CP200 Compatible MZX detectors: M613 Series. LI800 Line Isolator Module The LI800 is designed to be used on all MX addressable loops. It monitors the line condition and upon detection of a short circuit it isolates the affected section whilst allowing the rest of the addressable loop to function normally. The LI800 ensures that on a looped addressable system a short circuit fault cannot disable more detection devices than would be lost on a conventional non-addressable system in accordance with BS5839 Part 1. RIM800 Relay Interface Module The RIM800 provides a single programmable relay output from the MX DIGITAL addressable loop which can be programmed for a variety of applications including signalling fire conditions to plant, machinery, fire doors, dampers & security systems. The RIM800 relay coil is monitored. The RIM800 relay contact is rated for 2A @ 24V d.c. but can be used to switch mains voltage when used with the HVR800. LPS800 Loop Powered Sounder Module The LPS800 provides a single monitored sounder output circuit with up to 75mA of power sourced from the MX panel loop. PSF127T.indd 2 13/12/2012 09:59:50

SNM800 Sounder Notification Module The SNM800 is a remote addressable sounder circuit output device capable of switching sounder and speaker circuits up to 2A @ 24V d.c. or provide a monitored output facility for other applications. These can be used in addition to the two sounder circuits provided as standard on most MX detection panels. The SNM800 can support sounder circuits wired as a spur (Class B Style Y) or in a loop configuration (Class A Style Z). The SNM800 can be configured with a RIM800 to provide a secure monitored extinguishing release solenoid control. TM520 Timer Module The TM520 provides an output that can be activated based on a delay time. If either the key-switch on the module is activated, or a predefined event within the control panel occurs then a timed delay (set between 10 minutes and 2 hours 10 minutes) is started. When the delay reaches zero the TM520 output is activated. The unit sounds an internal buzzer and shows a red LED when the output is active, and shows a yellow LED when the timer is counting down. To provide a warning that the delay is nearly over, the red LED and the buzzer will pulse 5 minutes before the end of the delay. The TM520 requires a separate 24V DC supply to operate. The module is not addressable and will therefore not take an address on the loop. APM800 Addressable Power Supply Monitor Module The APM800 is an MX addressable power supply monitoring module which is usually used with the PSM800 power supply module to make an addressable power supply. The APM800 is designed to fix to studs on the top of the PSM800. The APM800 monitors the PSM800 for mains failure, earth fault, battery charger fault and battery fault. It can reset the PSM800 resettable 24Vd.c. output and initiate a battery test which then reports battery voltage and current to the controller. SB520 Sounder Boost Module The SB520 enables the SNM800 to drive sounder circuits with higher currents whilst maintaining the reverse polarity integrity line monitoring. MIM800 Mini-Input Module The MIM800 is a small MX addressable module designed for monitoring a single input circuit. The MIM800 can monitor normally open or normally closed inputs and provides open and short circuit monitoring of the line. The MIM800 is designed for fitting in small devices such as flow switches, special detection devices and explosion proof callpoints. A variant of the MIM800 is used in all callpoints and pullstations. PSF127T.indd 3 13/12/2012 09:59:51

HVR800 High Voltage Relay The HVR800 is a non-addressable device which allows a low current mains rated relay to switch up to 10A. Alternatively a low voltage drive signal such as that provided by the RIM800 or 80 way mimic can be used to switch the integral mains relay. SIO800 Single Input/Output Module The SIO800 is designed to provide a monitored input and a volt free relay changeover output. It consists of an input for monitoring the status of a normally open contact and output changeover relay contact. The relay is controlled by a command sent from the MX Fire Controller via the addressable loop. The state of the relay (activated, deactivated or stuck) is reported to the MX Fire Controller. The LED may be turned ON or OFF by the controller during a relay activated condition. CP820 Indoor Callpoint The CP820 is an indoor MX addressable manual callpoint with programmable status LED. The CP820 is designed for LPCB approvals. The CP820 provides high speed communication to the MX panel of a manual fire alarm. CP830 Outdoor Callpoint The CP830 is an outdoor MX addressable manual callpoint with programmable status LED. The CP830 is designed for LPCB approvals. The CP830 provides high speed communication to the MX panel of a manual fire alarm. PSF127T.indd 4 13/12/2012 09:59:52

Double Gang Mounting Cover The double gang mounting cover allows any of the 800 module range to be mounted individually onto a standard electrical double gang backbox. The mounting cover allows either surface or flush mounting. Ancillary Housing 8 The Ancillary Housing 8 can incorporate:- 8 x standard 800 Ancillary modules Additionally a stacking kit is available that doubles the number of modules that can be accommodated within the Ancillary 8 housing. Ancillary Housing 3 The Ancillary Housing 3 is a low cost plastic housing that can incorporate:- 3 x standard 800 Ancillary modules D800 Ancillary Housing The D800 Ancillary Housing is a surface mount IP55 plastic housing which will accommodate any one of the 800 module range except for the APM800/MIM800/ TM520. PSF127T.indd 5 13/12/2012 09:59:53

Module No. Of Inputs No. Of Outputs Output Rating Used No Of Addresses Powered From Operating Temperature Operating Humidity Dimensions (mm) CIM800 2 N/A 1 Loop -25 o C to +70 o C <95% RH 60 x 84 x 14 DIM800 2 N/A 1 24V dc -25 o C to +70 o C <95% RH 60 x 84 x 14 LI800 N/A N/A Loop -25 o C to +70 o C <95% RH 60 x 84 x 14 LPS800 N/A 1 75mA at 1 Loop -25 o C to +70 o C <95% RH 60 x 84 x 14 24Vdc RIM800 N/A 1 24Vdc 2A 1 Loop -25 o C to +70 o C <95% RH 60 x 84 x 14 SB520 N/A 1 15A for 24V dc PSU -25 o C to +70 o C <95% RH 60 x 84 x 14 sounders SNM800 N/A 1 2A for 1 24V dc PSU -25 o C to +70 o C <95% RH 60 x 84 x 14 sounders TM520 1 1 24Vdc 1A 24V dc PSU -20 o C to +70 o C <95% RH 87 x 148 x 14 APM800 N/A N/A N/A 1 PSM800-25 o C to +70 o C <95% RH 57 x 127 x 25 MIM800 1 1 4.5mA 1 Loop -25 o C to +70 o C <95% RH 13 x 48 x 57 HVR800 1 1 10A at 24Vdc/ 240Vac 24Vdc/ 24Vac/ 120Vac/ 240Vac -25 o C to +70 o C <95% RH 26.5 x 73.6 x 41.5 SIO800 1 1 24Vdc 2A 1 Loop -25 o C to +70 o C <95% RH 60 x 84 x 14 CP820 N/A N/A N/A 1 Loop -25 o C to +70 o C <95% RH 87 x 87 x 19 CP830 N/A N/A N/A 1 Loop -25 o C to +70 o C <95% RH 135 x 135 x 30 Thorn Security is a leading brand of fire detection products in the Middle East market. The Thorn Security fire detection product line includes a wide range of MZX TECHNOLOGY EN54 CPD approved fire detection products carrying approvals and cross-listings, including LPCB and VdS. The Thorn Security product lines are available through Thorn Security dealers in the Middle East. For more information, visit www.thornsecurity.net or contact us by e-mail at thornsecurity@tycoint.com. PSF127T - December 2012 Safer. Smarter. Tyco. PSF127T.indd 6 13/12/2012 09:59:53