EasyLog Data Logger Series

EasyLog Data Logger Series

Advanced Autoclave Controller with Recording + 4 Channel Mapping + Pressure Indication with PC Software & Printer Module

EL-USB-1-LCD Temperature Data Logger with LCD

EL-USB-2-LCD+ High Accuracy Humidity, Temperature and Dew Point Data Logger with LCD

EL-OEM-3 OEM Packaged Voltage Data Logger

PSE-367C. AL4000 SERIES 100mm chart MULTI-POINT TYPE HYBRID MEMORY RECORDER

MicroTool. Not just a simple Measuring Instrument A complete Tool to support your daily activities FLUE GAS ANALYSERS

EL-USB-1-LCD Temperature Data Logger with LCD

PSE-368. AH4000 SERIES 180mm chart MULTI-POINT TYPE HYBRID MEMORY RECORDER

EL-USB-TC Thermocouple Data Logger with USB Interface

Specifications Minimum Typical Maximum Unit

AL3000 SERIES 100MM CHART MULTI-POINT TYPE HYBRID RECORDER

PSE-805A. AL4000 SERIES 100mm chart PEN HYBRID MEMORY RECORDER

IRtech. E instruments. IRtech Radiamatic IR20 LS series. Infrared Technology

ELMTEC. Kattreppeln Königslutter / /

THERMOMETERS Dataloggers/Refrigerator

PRESENTATION OVERVIEW OF THE DIFFERENT MODELS MONITORS

Data Logging Solutions

ORDERING INFORMATION FEATURES EL-WIN-USB (CONTROL SOFTWARE) Maximum Speci cations Typical Minimum Unit

Compact Ultra Low Temperature Chamber

4/8/12/16 Channel Temperature Scanner with FREE Data Logging PC Software RS485

AH3000 SERIES 180MM CHART PEN TYPE HYBRID RECORDER

EL-USB-CO300 Carbon Monoxide (CO) Data Logger with USB Interface

PROCESS & TEMPERATURE UNIVERSAL INPUT DIGITAL METERS

Infrared Temperature Sensor

EMS510 PS-1 COMPLIANT OPACITY/DUST MONITOR

Instruction Sheet THERMOCOUPLE DATA LOGGER WITH LCD DISPLAY AND USB INTERFACE

Process & TeMPerATUre UniversAl input DigiTAl MeTers

Ventostat Wall Mount. Amphenol Advanced Sensors. Telaire Wall Mount CO 2. , Humidity and Temperature Transmitters. Features:

PORTABLE ISOTOPE IDENTIFIER Search Tool / Sample Counting System

Sentry G3 Machinery Protection Monitor

Dew point set DS 400

PACSystems* RX3i. Thermocouple Input Module, 12 Channels, IC695ALG412. GFK-2578B October 2011

PSE-369A. KL4000 SERIES 100mm chart DOT-PRINTING TYPE HYBRID RECORDER

Synergy Controller Application Note 125 January 2016, Revision A Tidal Engineering Corporation 2016

Temperature Data Logging

Measuring Recording Online Monitoring Regulation Alarming

External Dimensions: B = 600 mm D = 630 mm H = 2000 mm. Internal Dimensions: B = 451 mm D = 430 mm H = 1598 mm

WeatherLink for Alarm Output Addendum


Temperature + Humidity (%RH) Control & Recording System with 8 / 16 Channel Mapping. Touch Panel PPI

I/A Series 716C 1/16 DIN Temperature Controller

User Manual. Digi-Sense TC9600 Advanced Multiparameter Temperature Controller with Thermocouple, Thermistor, and RTD Inputs

Our photo detectors are offered for both power or energy measurements. Measure as low as a few femtojoules in energy or a few picowatts in power.

ECOLOG-NET LA8 and WA8 (wireless), 8 x 4..20mA signals

STT 3000 Series STT250 Smart Temperature Transmitters Specifications Models STT25T EN0l-6091 February 2009

Advanced Test Equipment Rentals ATEC (2832)

Sentry G3 Machinery Protection Monitor

HOBO U14 Data Logger User Manual

Our photo detectors are offered for both power or energy measurements. Measure as low as a few femtojoules in energy or a few picowatts in power.

HOBO U30 Remote Monitoring Systems

User Manual. Digi-Sense TC9500 Advanced Multiparameter Temperature Controller with Thermocouple, Thermistor, and RTD Inputs

CDR-AL Room CO 2 Traffic Light Alarm Units and Sensors

Sirius Technologies, Inc.

Introduction Portable Meters Transmitter Probes RELATIVE HUMIDITY

PRESENTATION OVERVIEW OF THE DIFFERENT MODELS MONITORS

A660 Air Conditioning Laboratory Unit

Smart Wireless Sensor

D3 Wireless temperature alarm & monitoring system family. tek-troniks

PRESENTATION OVERVIEW OF THE DIFFERENT MODELS MONITORS

Smart Wireless Sensor

MR SERIES CARD LOGGERS

OVEN INDUSTRIES, INC.

Module Features are-configurable, no module jumpers to set

Dew point. Special features: Dew point monitoring DS 400. Technical data DS 400. Technical data FA 510

Beam-A-Temp Portable Infrared Thermometer Measures up to 1832 F/1000 C with 50:1 distance to target ratio. Specifications

data logger DL200H DL200D DL200L

Ventostat Wall Mount. Amphenol. Telaire Wall Mount CO 2. , Humidity and Temperature Transmitters. Advanced Sensors. Features:

Date SECTION MEASUREMENT AND CONTROL INSTRUMENTATION Project Name Page 1

Laboratory Refrigerator/Deep Freezer TC 802

PHOENIX L300i New Standards in Helium Leak Testing The next Generation

GMA 301. Operation Manual. Worldwide Supplier of Safety Solutions. Part Number

STT 3000 Series STT250 Smart Temperature Transmitters Specifications Models STT25H, STT25S, STT25M, STT25D EN0I-6031 March 2010 Rev.

Sintrol Snifter A2 EX. Manual. Version 1.2.3

Instruments. for hydroponics & horticulture 2016

Analog Input Module IC670ALG630

IR15TT-R Miniature Infrared Gas Sensor for Monitoring Carbon Dioxide and Methane up to 100% Vol.

Refrigerator/Freezer Thermometer

Industrial Grade Gas Detection Detecting The Difference

User Manual. Humidity-Temperature Chart Recorder. Model RH520

8-Channel Thermocouple Input Ethernet Data Acquisition Module

MultiMeter 44. Transmitter-regulator with 1, 2 or 3 channels. Quality at a reasonable price

OLIP SYSTEMS INC. OLIP Intelligent Wireless Condition Monitoring System

EL-OEM-3 OEM Packaged Voltage Data Logger

Monitoring system. testo 160 Monitoring system for the monitoring of temperature, humidity, light intensity, UV radiation and CO 2. concentration.

Laboratory Deep Freeze Storage Cabinet TC 230 Air circulated

ABB Instrumentation. Specifications. COMMANDER 150 Universal Process Indicator. the 1 /8 DIN indicator to match all your display requirements

Refrigerator/Freezer Thermometer

IR1xxx Series 1, IR2xxx Series 1 Miniature Infrared Gas Sensors for Hazardous Areas and Intrinsic Safety in Mining

Tinytag Plus LAN Data Logger with Temperature & Relative Humidity Probe (-25 to +85 C/0 to 100% RH) Standalone. Tinytag Connect

External Dimensions: B = 750 mm D = 700 mm H = 2100 mm. Internal Dimensions: B = 600 mm D = 580 mm H = 1270 mm. Temperaturerange: 2 C to 20 C

Laboratory Air circulated Refrigerator/Deep Freezer TC Two-door (2 independent temperature ranges)

Operations Manual TS400. Test Station for G450/G460 Gas Detector

Multifunction IAQ Monitor

Ventostat Wall Mount. Telaire Wall Mount CO 2. , Humidity and Temperature Transmitters. GE Sensing & Inspection Technologies.

Ventostat Wall Mount. Telaire Wall Mount CO 2. , Humidity and Temperature Transmitters. GE Sensing & Inspection Technologies.

VIBRA-series: VIBRA, VIBRA +

Medical Air circulated Refrigerator TC (2 independent temperature ranges), also in accordance with DIN 58345

FEATURE ARTICLE. The PLCA-800 Series Inline Particle Sensor for Chemical Solutions. Yoshihito Yuhara. Abstract

Transcription:

Product introduction for PetitLOGGER GL100 series (vol 1, rev 1.0) Graphtec Corporation Overseas Sales and Marketing Division

Business Concept (Development of the compact Data Logger) Graphtec released the GL400 in 2003. It is the starting point of the current midi LOGGER series. Enhancing line-up of midi LOGGER has been continued in order for corresponding to customer needs. In 2012, Graphtec developed the GL7000 series that is the top model of digital recording equipment. GL7000 is the modular type data acquisition unit, it can be satisfied the customer demands like channel expansion, multiple input, system support, operability enhancement. Now, Graphtec releases the compact logger for simple measurement market. It is able to enter to new large markets towards expanding sales and market. It is modular type that is able to support variety measurement by exchanging the input module. GL100 series Product Information - Page 1 - Overseas Sales and Marketing Dep.

Business Concept (Entry into the new area) Increase sales in market expansion and expanding category of measurement products Existing market 2010 2012 2014 Year Vehicle Laboratory Data Acquisition GL7000 Railway Iron & Steel Recorder WR3320A WR300 expansion Data Logger GL220 GL820 High value-added Agriculture Logistics Maintenance Compact Logger New entry GL100 series Product Information - Page 2 - Overseas Sales and Marketing Dep.

Situation of Measuring Instruments (Market of compact logger) Market volume of the compact logger Market of the Compact Logger (Card Logger) in JAPAN Others; Chino, Omron, Fujita HIOKI 0.6 billion 0.2 billion 1.2 billion Expected annual sales: JPY 2 billion Reference by the Electric Measuring Instruments Manufacturers' Association Product of T&D company accounted for approximately 60%. (there are 20 models) T&D Large market size Used in various places depending on the application in research institutes, factories, agriculture, logistics, stores, etc. T&D: 55,000 units/year (estimated sales volume) Major model: Temperature and Humidity Measurement item HIOKI: 35,000 units/year (estimated sales volume) Major model: Temperature and Humidity Measurement item Temp. Humidity Atmospheric Illuminance/UV Carbon dioxide Voltage/4-20mA Pulse Rainfall 30 models to fit applications (Dedicated unit for measurement type) 9 models in total to fit applications (Dedicated unit for measurement type) SRIC: 400 units (estimated sales volume) (Top reseller of compact vibration measurement in Japan) 2 models of vibration measurement and Temperature/Humidity GL100 series Product Information - Page 3 - Overseas Sales and Marketing Dep.

Situation of Measuring Instruments (Requirement of compact logger) Required function of each application Supported in new logger Requirements in market Temperature by Thermistor (Built-in) Temperature by Thermistor (External) Temperature and Humidity Temperature by thermocouple Type of measurement Temperature by RTD Warehouse New Museum New Freezer, Refrigerator New Chemical closet, New Blood Storage Factories, Building Exist Agriculture New Transport, Logistics New Universities, Exist Institutes GL100 series Product Information - Page 4 - Overseas Sales and Marketing Dep. Voltage Current Pulses Carbon dioxide Illuminance Acceleration Power Dust-proof, drip-proof Battery drive Alarm output

Product Outline PetitLOGGER GL100-N (without Wireless LAN) Supports digital input module. Providing a variety of sensors and input terminals corresponding to the application. It automatically recognise type of module (sensor or input terminal). Destination of captured data: Built-in memory (4.9MB) micro-sd memory card Output signal: Alarm, 1 ch USB port USB interface, micro-sd memory card PC LCD: Back-lit monochrome, graphical type Water resistance: IP54 ( * ) Power: USB bus-power, Alkaline battery (AA x 2) * It is effective only in the condition that the input module is set to the GL100 and then the covers of connector and battery are closed. GL100 series Product Information - Page 5 - Overseas Sales and Marketing Dep.

Target Market Machinery Automobile Vehicle Iron /steel industry Consumer /Home electronics University /Research institute Conventional markets GL100 Develops to new markets towards expanding sales and market Agriculture Transportation /Logistics Food processing Chemical Warehouse Museum New markets Open up new markets of large size GL100 series Product Information - Page 6 - Overseas Sales and Marketing Dep.

Distribution network Expands new sales network Expanding of a new sales network for PR into large size new markets is required for success of compact data logger. GRAPHTEC GRAPHTEC Distributor Distributor Dealers Dealers Catalog retailer WEB End user Entry-class Logger GL100 End user GL100 series Product Information - Page 7 - Overseas Sales and Marketing Dep.

Main features of GL100 Easy measurement by multifunction input Providing a variety of sensors and input terminals corresponding to the application There is the following input module. The connected input module is automatically recognized. Sensor module: Temperature & Humidity, Acceleration & Temperature, Illuminance & UV, AC Current, Carbon dioxide (CO2) Input terminal module: Voltage & Thermocouple, Thermistor Available the application software for the PC and the Smart Device Checking data trends and converting data file format using PC software Will be available the software for the specific-industrial of the Agriculture, Logistics, and Power Possible to check the data in multiple method Easy data transfer to PC using the SD memory card (when GL100 is not connected to PC) Possible to check the data by waveform or digital value with the PC (when GL100-N is connected to PC vis the USB) GL100 series Product Information - Page 8 - Overseas Sales and Marketing Dep.

Modules of GL100 (1) Easy measurement by multifunction input Input Module: It is corresponding to multiple measurements by connecting the input module. The connected input module is automatically recognized by the GL100. GL100-WL (with WLAN) GL100-N (without WLAN) Sensor Temp./Humidity Acceleration/Temp. Carbon dioxide Illuminance/UV Input terminal module Thermistor sensor AC current sensor Voltage/Temp. Temp. input terminal 2 types AC current sensor adapter 3 models Dual Port Adapter: Two sensors are able to connect and measure simultaneously by using the dual port adapter. Possible combination is shown in below. GL100 + Dual port adapter + Temp./Humidity sensor + Illuminance/UV sensor GL100 + Dual port adapter + Temp./Humidity sensor + Carbon dioxide sensor GL100 + Dual port adapter + Illuminance/UV sensor + Carbon dioxide sensor GL100 series Product Information - Page 9 - Overseas Sales and Marketing Dep.

Modules of GL100 (2) Accommodate a wide variety measurements by the input module The sensors for capturing data in wide variety measurement are available. It is able to exchange input module for the requirement. The connected sensor is automatically recognized by the GL100. Sensors No. 1 Input module Temp./Humidity sensor GS-TH Measurement (actual sensing) Temperature (-20 to 85 ºC), Humidity (0 to 100 % RH) Measurement (calculated value) Accumulated temperature, Dew-point temperature No. 1 No. 4 2 Acceleration/Temp. sensor GS-3AT Acceleration in 3-axis (max. 10 G), Temperature (-10 to 50 ºC) N/A 3 Illuminance/UV sensor GS-LXUV Illuminance (max. 200 k lx), UV intensity (max. 30 mw/cm 2 ) Accumulated Illuminance, Accumulated UV intensity No. 2 No. 5 4 Carbon dioxide sensor GS-CO2 CO 2 concentration (max. 9999 ppm) N/A 5 AC current sensor adapter GS-DAP-AC AC current (max. 200 A AC RMS), 2 sensors are able to connect Power (instantaneous), Integrated power (Electric energy) 6 AC current sensor GS-AC200A Clamp-on type (max. 200 A AC), use with GS-DAP-AC module N/A No. 3 No. 6 No. 7 No. 8 7 AC current sensor GS-AC100A Clamp-on type (max. 100 A AC), use with GS-DAP-AC module N/A 8 AC current sensor GS-AC50A Clamp-on type (max. 50 A AC), use with GS-DAP-AC module N/A GL100 series Product Information - Page 10 - Overseas Sales and Marketing Dep.

Modules of GL100 (3) Accommodate a wide variety measurements by the input module The input terminal for measuring the voltage and the temperature are available. It is able to exchange input module for the requirement. The connected sensor is automatically recognized by the GL100. Input terminals No. Input module No. 9 9 Voltage/Temp. input module GS-4VT Voltage (max. 50 V) or Temp. (TC: K/T type) of 4 ch, Logic or Pulse of 4 ch 10 Temperature input terminal GS-4TSR Thermistor (max. 120 ºC) of 4 ch, Logic or Pulse of 4 ch 11 Thermistor sensor (Normal type) GS-103AT-4P Temperature sensor (-40 to 105 ºC), use with GS-4TSR module No. 10 12 Thermistor sensor (Ultrathin type) GS-103JT-4P Temperature sensor (-40 to 120 ºC), use with GS-4TSR module No. 11 No. 12 GL100 series Product Information - Page 11 - Overseas Sales and Marketing Dep.

Combined models of GL100 Packages will include combined models best suited for your application GL100 will feature package solutions that combines several sensors and modules together for a one stop solution as an out-of-the-box-ready item for the specific application that best fits your need. Combo models for GL100-N Package Model name GL100-N GS-TH 1 Temp./Humidity Set GL100-N-TH & GL100-N GS-3AT 2 Acceleration Set GL100-N-4VT & GL100-N GS-4VT 3 Voltage/Temp. Set GL100-N-3AT & GL100-N GS-4TSR 4 Thermistor Set GL100-N-4TSR & (The thermistor sensor is not included.) GL100 series Product Information - Page 12 - Overseas Sales and Marketing Dep.

Software for GL100 (1) Available the application software for the PC and the Smart Device Includes Application Software for the PC Software for general-purpose General purpose application software will continue to have the ability to view in Y-T chart, waveform, and digital values. It is able to be controlled in real-time. Menu for connection Y-T Chart Display Capture Settings Full conditions; Meas. range, Capturing, Alarm, etc. Digital value TAB-based display options Statistics GL100 series Product Information - Page 13 - Overseas Sales and Marketing Dep.

Software for GL100 (2) Software for specific-industry The new industry-specific customize software will feature targeted software in accommodating users with indicators that are specific and familiar to that industry. Agriculture Indicators of plant growth Accumulated temperature Humidity Deficit Amount of solar radiation Amount of ultraviolet rays Logistics Indicators of safe transportation and storage Search and display acceleration thresholds Accumulated temperature Humidity Deficit Power Indicators of electric energy AC current Power Integrated power Available to download at the autumn of 2014 Specificindustry Agriculture Logistics Power measurement Measurement items Temperature Accumulation Humidity Deficit Amount of solar radiation Amount of ultraviolet rays Search and display acceleration thresholds Temperature Accumulation Humidity Deficit AC current Power Integrated power Confirm temperature accumulation, humidity deficit, solar radiation, ultraviolet rays as part of the vital indicators for healthy plant growth. Measure optimal saturation deficit by understanding the best conditions applied for growth, flowering, and fruit growth using temperature accumulation and optimal growth environment scheme. Transportation of industrial equipment, temperature controlled transport of food, and warehouse temperature management can all be monitored to provide the safest and secured operation. Safety measurements through monitoring the vibration of the transport vehicles can be vital to heavy-industrial and vibration sensitive equipment. Accumulated temperature monitoring and humidity levels will be vital to keeping food fresh in a controlled environment. Power and electric energy levels will be displayed on the graph using measured AC current locally at the factory, buildings and industrial equipment. Corresponds to three power systems including two-wire single-phase, three-wire single-phase, or three-wire in three-phase. GL100 series Product Information - Page 14 - Overseas Sales and Marketing Dep.

Measuring using GL100 (1) Possible to check the data in multiple method Monitors data easily in multiple methods The GL100 is able to use with the PC in on-line or off-line condition. In the on-line condition; USB connection is available through the GL100 with real-time control from the PC software. Historical data can also be viewed by directly accessing the internal memory of the GL100 from the PC software. In off-line condition; Data stored on the GL100 can be easily transferred to the PC using a micro SD memory card and replay in the PC software. GL100 On-line connection USB cable Off-line connection micro SD memory card General purpose application software will continue to have the ability to view in Y-T chart, waveform, and digital values. Note: Application software for general-purpose is the GL100-APS. The new industry-specific customize software will feature targeted software in accommodating users with indicators that are specific and familiar to that industry. Note: Software for specific-industry will be available at the autumn of 2014. GL100 series Product Information - Page 15 - Overseas Sales and Marketing Dep.

Measuring using GL100 (2) Supports multiple configurations for access to GL100 The following configuration is available to communicate with the GL100. The available function varies by the configuration. No Connection to the PC Peer-to-Peer Connection Replay data micro SD memory card Control (Full) Display data Save data USB cable PC GL100-WL/N PC GL100-WL/N Configuration; The GL100 is not connected to the PC. Available function of this case; The data stored on the GL100 can be easily transferred to the PC using a micro SD memory card and replay in the PC software. Display the saved data (replay the stored data) Configuration; The GL100 is connected to the device using the USB in peer-to-peer condition. (In other word, those are connected in one-to-one.) Available function of this case; The GL100 is able to be controlled in real-time from the application software for PC. It can also be displayed real-time data or historical data. Control of full functions Display waveform or digital value on the PC Save data to the PC GL100 series Product Information - Page 16 - Overseas Sales and Marketing Dep.

Other Functions for GL100 (1) Reliable measurement with useful functions Sufficient capacity of data The captured data is able to save to the built-in memory or the micro SD memory card. It has sufficient capacity of data. Available memory: Built-in memory (approx. 4.9MB), micro SD memory card Data Capturing Time Condition: Using with Temp/Humidity sensor (GS-TH) by 1 minute sampling interval. Destination Built-in memory (approx. 4.9 MB) micro SD memory card Capturing time Approx. 296 days Over 2 years * File size for captured data is up to 1.9GB on the micro-sd memory card. GL100 series Product Information - Page 17 - Overseas Sales and Marketing Dep.

Other Functions for GL100 (2) Available battery operation The GL100 can be operated with batteries or USB bus-power. The power of the GL100 is automatically switched between the battery and the USB bus-power. Battery Operating Time Condition: Using with Temp./Humidity sensor (GS-TH), 1 minute sampling interval, Alkaline battery (AA size x 2). The micro SD memory card is not installed. Condition When saving data to the built-in memory Operating time Approx. 2 weeks * The operating time varies by the environmental condition. * USB power source will be required for Voltage/Temp. (GS-4VT) and CO2 sensor (GS-CO2). Recommended power source for the sensor module Measurement items Input module Driven by battery ( * 2) Powered by USB ( * 4) Temp. & Humidity GS-TH Available Available Acceleration & Temp. GS-3AT Available Available 4ch, Voltage or Temp GS-4VT ( * 3) Available 4ch, Temp. (Thermistor) GS-4TSR Available Available Illuminance & UV GS-LXUV Available Available Carbon dioxide (CO2) GS-CO2 N/A Available AC Current & Power GS-DPA-AC Available Available Temp./Humidity + CO2 GS-DPA ( * 1) + GS-TH + GS-CO2 N/A Available Temp./Humidity + Illuminance/UV CO2 + Illuminance/UV GS-DPA ( * 1) + GS-TH + GS-LXUV GS-DPA ( * 1) + GS-CO2 + GS-LXUV Available N/A Available Available Note; *1: GS-DPA (Dual Port Adapter) is used for connecting two sensors. *2: When GL100 is driven by the USB bus-power, power is automatically switched to battery after USB bus-power is down. If the capacity of the battery is low, the power of GL100 may be turned off. The battery is able to use as an auxiliary power of a power failure of the USB bus-power. In this case, it is recommended to install new battery to GL100. *3: It is able to drive by battery. In this case, an operating time will be shorter because power consumption is relatively high. *4: When AC adapter for the USB device is used, it is recommended to have power capacity of the 200mA except to use the GS-CO2 sensor. The power capacity of the 1A is required for using the GS-CO2 sensor. GL100 series Product Information - Page 18 - Overseas Sales and Marketing Dep.

Other Functions for GL100 (3) Supports a convenient alarm function to monitor the situation Alarm function Alarm occur when the measuring data reaches the pre-set conditions. (Detection method: captured data level is higher or lower from threshold) Output signal Output signal related an alarm is turn on when the alarm condition is established by the captured data. Solid state switch with optical isolation is used. (Optocoupler, Max. load is the 30 V, 50 ma) Example; Temperature in the greenhouse is abnormally raised. GL100 (Carbon dioxide (CO2)) In the greenhouse GL100 (Illuminance) The alarm signal is outputted from the GL 100 to the controller of ventilation port for opening and closing. GL100 (Temp./Humidity) Output signal of alarm Controller Ventilation port (Be opened/closed) Ventilation port is opened by it. Then temperature will be falling. Note: Processing of the control signal depends on the equipment on the site. GL100 series Product Information - Page 19 - Overseas Sales and Marketing Dep.

GL100 Comparison Chart Comparison with other models Graphtec DATAQ microdaq T&D CHINO HIOKI Manufacturer and model PetitLOGGER EL-USB HOBO Indore Wireless System ONDOTORI MD8000 series Data mini Measurement Temp. (TC, Thermistor) Temp./Humidity Voltage Current (AC) CO2 Illuminance/UV Logic/Pulse Temp. (Thermistor, RTD) Temp./Humidity Voltage Current (4-20mA) Temp. (Thermistor) Temp./Humidity Voltage Pulse Temp. (TC, Thermistor, RTD) Temp./Humidity Voltage Current (4-20mA) Pulse CO2 Illuminance/UV Temp. (TC, Thermistor, RTD) Temp./Humidity Voltage Pulse Temp. (TC, Thermistor) Temp./Humidity Voltage Pulse Voltage (AC) Current (AC) Sensor system Modular Dedicated unit for measurement type Dedicated unit for measurement type Dedicated unit for measurement type Dedicated unit for measurement type Dedicated unit for measurement type Wireless connection N/A N/A IEEE802.15.4 2.4GHz Specified low-power (429MHz) Specified low-power (429MHz) Specified low-power (429MHz) Display Available Available Available Available Ext. memory micro-sd N/A N/A N/A N/A N/A Alarm output From GL100 N/A From PC software Base station Base station Major application Home electronics Electric Automobile Vehicle Logistics Museum It is able to use in variety industries by changing sensor according to the application. Various research Monitoring application (Energy management, Field research, Water management) Measurement in moving Environmental (Agriculture, warehouses, display shelf, building, factories, curing) Food production Management of equipment and facilities Barn in the environment Temperature management High-temperature sterilization Power plant coal bunker Nursery house monitoring Clean room environment Chemical warehouse Noodles manufacturing Agriculture Energy-saving (room, air-conditioning, super market, rooftop gardens) Maintenance of facilities (gas, flow rate, motor, chemical closet) Environmental (water position of river/well, rainfall, curing temperature and humidity, transport, sea and rail vehicle) GL100 series Product Information - Page 20 - Overseas Sales and Marketing Dep.

GL100 series Specifications (Main body) Main unit (GL100-N) 1/2 Item Number of channels Input method, Type of input terminal Output signal Interface to PC Storage device Memory content Display Functions Alarm Varies by the input module used, and measurement type is fixed with each input module Alarm (1 channel), solid state switch with optical isolation (Optocoupler, Max. load is the 30 V, 50 ma) USB (micro USB B type connector) Built-in memory: RAM (Approx. 4.9 MB) External memory: micro-sd memory card * Maximum file size for captured data is 1.9MB. It is recommended to use the micro-sd memory card that supports sleep mode. (Example: TS4GUSDHC4, made by Transcend) Captured data LCD (backlit monochrome, graphical type 128 x 64 dots) Contents: Captured data and Setting menu (Stored data is not able to replay. It is able to replay using the PC application software.) Real-time data capturing Display the captured data value to the LCD in real-time and save the monitoring values Set conditions using the Menu setting While using USB port: Output captured data in real-time Output the saved data from the internal memory Full control of the GL100 from the PC application software Action Outputs the signal when the measuring data reaches the present conditions of alarm Source Level of measuring data Detecting in the Level Condition: Higher or lower (signal is higher or lower than the threshold) Combination: OR GL100 series Product Information - Page 21 - Overseas Sales and Marketing Dep.

GL100 series Specifications (Main body) Main unit (GL100-N) 2/2 Item Trigger Dustproof and waterproof Vibration resistance Power source Operating environment External dimension [W x D x H] Weight Action Start or stop the recording of captured data by trigger Source Start trigger: OFF, Level ( * ), Alarm, or Date Stop trigger: OFF, Level ( * ), Alarm * Level trigger is available in the analog input of the GS-4VT, GS-4TSR, and GS-3AT module. Detecting method of the Level ( * ) Condition: Rising or Falling (signal is passed through the threshold) Combination: OR or AND IP54 compatible ( * ) * It is effective only in the condition that the input module is set to the GL100 and then the covers of connector and battery are closed. It is recommended to replace the packing of cover in periodically. Compatible with equivalent of the JIS Vibration Testing methods for Automobile Type 1 Class A Alkaline battery (AA size x 2) USB bus-power (5V, 200 ma) ( * ) * When AC adapter for USB drive is used, the required power capacity is 5V, 1A. Battery and AC adapter is not included. Temperature: -10 ºC to 50 ºC Humidity: up to 80 % RH (non condensed) Approx. 66 x 100 x 27 mm (exclude protrusion) Approx. 125 g GL100 series Product Information - Page 22 - Overseas Sales and Marketing Dep.

GL100 series Specifications (Input module 1) Temperature & Humidity sensor (GS-TH) Item Type of measurement Method of measurement Measuring range Actual measuring Calculated value Temperature Humidity Temperature Temperature and Humidity Dew-point temperature and Accumulated temperature (The temperature will be accumulated during it is higher or lower than the reference temperature.) C-MOS sensor -20 to 85 ºC 0.0 to 100.0 % RH -20 TS < 0: 0.8 ºC 0 TS 60: 0.5 ºC 60 < TS 85: 0.8 ºC Accuracy Response Sampling interval Humidity at 25 ºC Measuring 0 to 10 % RH: 10% RH Measuring 10 to 20 % RH: 8% RH Measuring 20 to 80 % RH: 5% RH Measuring 80 to 90 % RH: 8% RH Measuring 90 to 100 % RH: 10% RH Temperature, Humidity: Approx. 100 seconds (Time to reach 63%, at 25 ºC and air flow 1 m/s) * It varies by environment condition. 0.5, 1, 2, 5, 10, 20, 30 seconds, 1, 2, 5, 10, 20, 30, 60 minutes Unit of temperature measurement Switchable ºC and ºF External dimension [W x D x H] Weight Approx. 15 x 45 x 10 mm (exclude protrusion) Approx. 14 g GL100 series Product Information - Page 23 - Overseas Sales and Marketing Dep.

GL100 series Specifications (Input module 2) Acceleration & Temperature sensor (GS-3AT) Item Type of measurement Acceleration Measuring range Temperature Acceleration Accuracy Temperature Response (acceleration measurement) Noise (acceleration measurement) Measuring mode Memory capacity Pre-trigger Sampling interval Calculation function (in Direct mode) Acceleration in 3-axis (X-, Y-, Z-axis) and Temperature 2 G (20m/s 2 ), 5 G (50m/s 2 ), 10 G (10m/s 2 ) -10 to 50 ºC (using C-MOS sensor) 2 % of F.S. (including non linearity) -10 TS < 50: 1.0 ºC 0 Hz to 100 Hz 25 mg RMS Memory, or Direct mode 16, 32, 64, 128 k Samples (for memory mode) 10, 25, 50, 100 % of selected memory capacity, and OFF (function is available for memory mode) Memory mode: 5, 10, 20, 50, 100 ms Direct mode: 0.5, 1, 2, 5, 10, 20, 30 seconds, 1, 2, 5, 10, 20, 30, 60 minutes Function: The data is captured in every 5ms interval, and then the result of calculation between selected interval will be saved. Type of calculation: Average, Peak, RMS, or OFF (selected one value will be saved) Unit of temperature measurement Switchable ºC and ºF Offset adjustment function Dustproof and waterproof Length of cable Operating environment External dimension [W x D x H] Weight OFF, ON (sets the static acceleration value of current to zero) IP54 Approx. 200 mm Temperature: -10 ºC to 50 ºC Humidity: up to 80 % RH (non condensed) Approx. 51 x 36 x 20 mm (exclude protrusion) Approx. 64 g GL100 series Product Information - Page 24 - Overseas Sales and Marketing Dep.

GL100 series Specifications (Input module 3) Illuminance & Ultraviolet sensor (GS-LXUV) Item Type of measurement Measuring range Measuring accuracy Spectroscopic accuracy resolution of measurement Response Accumulating function Sampling interval Length of cable Actual measuring Calculated value Illuminance UV intensity Illuminance UV intensity Illuminance UV intensity Illuminance UV intensity Illuminance UV intensity Illuminance UV intensity Illuminance and UV intensity Accumulated illuminance and Accumulated UV intensity 0 lx to 200 k lx 0 to 30 mw/cm 2 5 % at 25 ºC (Temperature characteristic: 5 % at 10 ºC to 40 ºC) 5 % at 25 ºC (Temperature characteristic: 5 % at 10 ºC to 40 ºC) 400 to 750 nm (peak 560 nm) 260 to 400 nm (peak 370 nm) 0.1 lx 0.001 mw/cm 2 1 ms or less 1 ms or less 0 to 99999 (ninety nine thousand) k lxh (Accumulated value is reset by starting the data recording or pressing the QUIT key.) 0 to 99.999 (ninety nine) W/cm 2 h (Accumulated value is reset by starting the data recording or pressing the QUIT key.) 0.5, 1, 2, 5, 10, 20, 30 seconds, 1, 2, 5, 10, 20, 30, 60 minutes Approx. 200 mm Operating environment External dimension [W x D x H] Weight Temperature: -10 ºC to 50 ºC Humidity: up to 80 % RH (non condensed) Approx. 46 x 66 x 19 mm (exclude protrusion) Approx. 65 g GL100 series Product Information - Page 25 - Overseas Sales and Marketing Dep.

GL100 series Specifications (Input module 4) Carbon dioxide (CO2) sensor (GS-CO2) Item Type of measurement Method of measurement Measuring range Measuring accuracy Response Sampling interval Length of cable Operating environment External dimension [W x D x H] Weight Carbon dioxide concentration NDIR (Non Dispersive Infra-red) 0 to 9999 ppm 0.5 % of reading + 30 ppm (in range of 0 to 5000 ppm) 3 minutes or less 0.5, 1, 2, 5, 10, 20, 30 seconds, 1, 2, 5, 10, 20, 30, 60 minutes (Sensing of carbon dioxide is done at interval of 2 seconds or slower. When sampling is selected to 0.5 or 1 second, the same value is recorded in each time and then value is updated every 2 seconds.) Approx. 200 mm Temperature: 0 ºC to 50 ºC Humidity: up to 80 % RH (non condensed) Approx. 66 x 100 x 25 mm (exclude protrusion) Approx. 99 g GL100 series Product Information - Page 26 - Overseas Sales and Marketing Dep.

GL100 series Specifications (Input module 5) AC Current sensor Adapter (GS-DPA-AC) & AC Current sensor Item Type of measurement Type of sensor Application circuit Number of sensor Actual measuring Calculated value Current (using optional Ac current sensor) Power, Accumulated power (Electric energy) Clamp-on current probe (optional) Single-phase two-wire, Single-phase three-wire, or Three-phase three-wire Two (2) sensors are able to connect (using the same type of sensor and the power system) Method of measurement Measuring range Applicable frequency Measuring accuracy Sampling interval Length of cable Operating environment External dimension [W x D x H] Weight Scans channels (sensors), Non-isolated input, using RMS converter 50, 100, 200 A RMS (varies by the sensor) 50 or 60 Hz 2 % of full sale 1 digit (at temperature 23 ºC, and within rated current and frequency) 0.5, 1, 2, 5, 10, 20, 30 seconds, 1, 2, 5, 10, 20, 30, 60 minutes Approx. 200 mm Temperature: -10 ºC to 50 ºC Humidity: up to 80 % RH (non condensed) Approx. 46 x 66 x 27 mm (exclude protrusion) Approx. 55 g AC Current sensor Item GS-AC50A GS-AC100A GS-AC200A Rated measuring current: 50 A AC (Length of cable to adapter is approx. 200 mm) Rated measuring current: 100 A AC (Length of cable to adapter is approx. 200 mm) Rated measuring current: 200 A AC (Length of cable to adapter is approx. 200 mm) GL100 series Product Information - Page 27 - Overseas Sales and Marketing Dep.

GL100 series Specifications (Input module 6) Voltage & Temperature Input Terminal (GS-4VT) 1/2 Item Type of measurement Number of channel Input method of voltage/temp. Measuring range of voltage Measuring accuracy Input impedance Signal source impedance Maximum input voltage Withstand voltage Analog voltage or Temperature, Logic (signal pattern) or Pulse (instant or accumulated count) Voltage/Temperature: 4 channels (measurement type for channels can each be separately selected) Logic/pulse: 4 channels (measurement type for channels can be selected as set of 4 channels) Scans by the photo-mos-relay, all channels isolated input 20, 50, 100, 200, 500 mv, 1, 2, 5, 10, 20, 50 V F.S. and 1-5V F.S. 0.15 % of F.S. 1 M ohms Up to 300 ohms Between positive ("+") and negative ("-") input terminal: 60 V Between negative ("-") terminal of channels: 60 V Between negative ("-") terminal of channel and "GND": 60 V Between negative ("-") terminal of channels: 350 V p-p (1 minute) Between negative ("-") terminal of channel and "GND": 350 V p-p (1 minute) Measuring range of temperature Thermocouple: K type -200 ºC to 1370 ºC, T type -200 ºC to 400 ºC Measuring accuracy Burnout checking K type -200 TS -100 ºC: (0.05% of reading + 2.0 ºC) -100 < TS 1370 ºC: (0.05% of reading + 1.0 ºC) T type -200 TS -100 ºC: (0.1% of reading + 1.5 ºC) -100 < TS 400 ºC: (0.1% of reading + 0.5 ºC) Reference Junction Compensation (R.J.C.): 0.5 ºC Displaying warning when Thermocouple has failed Unit of temperature measurement Switchable ºC and ºF GL100 series Product Information - Page 28 - Overseas Sales and Marketing Dep.

GL100 series Specifications (Input module 6) Voltage & Temperature Input Terminal (GS-4VT) 2/2 Item Input of Logic/Pulse Measuring rage of Pulse Sampling interval Length of cable Operating environment External dimension [W x D x H] Weight Input signal: Voltage or Dry contact signal Voltage input: 0 to +24V (common ground) Dry contact signal: Relay or Solid state relay Threshold voltage: Approx. +2.5V, Hysteresis: Approx. 0.5V (Status of the signal is changed in the 2V and the 2.5V.) Instant count: up to 200 counts/sampling interval Accumulated count: up to 65535 counts (Accumulated value is reset by starting the data recording or pressing the QUIT key.) 0.5, 1, 2, 5, 10, 20, 30 seconds, 1, 2, 5, 10, 20, 30, 60 minutes Approx. 200 mm Temperature: -10 ºC to 50 ºC Humidity: up to 80 % RH (non condensed) Approx. 46 x 66 x 36 mm (exclude protrusion) Approx. 85 g GL100 series Product Information - Page 29 - Overseas Sales and Marketing Dep.

GL100 series Specifications (Input module 7) Thermistor Sensor Input Terminal (GS-4TSR) Item Type of measurement Number of channel Input method of temperature Temperature sensor Measuring range Measuring accuracy Temperature, Logic (signal pattern) or Pulse (instant or accumulated count) Temperature: 4 channels (measurement type for channels can each be separately selected) Logic/pulse: 4 channels (measurement type for channels can be selected as set of 4 channels) Scans by the photo-mos-relay, all channels non-isolated input Thermistor (optional) Temperature: -40 to 120 ºC (varies by the type of sensor) (Sensor GS-103AT-4P: -40 to 105 ºC, GS-103JT-4P: -40 to 120 ºC) GL100 main body -40 TS < 0 ºC: 0.7 ºC 0 TS 35 ºC: 0.2 ºC 35 < TS 70 ºC: 0.4 ºC 70 < TS 120 ºC: 1.0 ºC Thermistor sensor (GS-103AT-4P or GS-103JT-4P) Typical 0.4 ºC Unit of temperature measurement Switchable ºC and ºF Input of Logic/Pulse Measuring rage of Pulse Sampling interval Length of cable Operating environment External dimension [W x D x H] Weight Input signal: Voltage or Dry contact signal Voltage input: 0 to +24V (common ground) Dry contact signal: Relay or Solid state relay Threshold voltage: Approx. +2.5V, Hysteresis: Approx. 0.5V (Status of the signal is changed in the 2V and the 2.5V.) Instant count: up to 200 counts/sampling interval Accumulated count: up to 65535 counts (Accumulated value is reset by starting the data recording or pressing the QUIT key.) 0.5, 1, 2, 5, 10, 20, 30 seconds, 1, 2, 5, 10, 20, 30, 60 minutes Approx. 200 mm Temperature: -10 ºC to 50 ºC Humidity: up to 80 % RH (non condensed) Approx. 46 x 66 x 36 mm (exclude protrusion) Approx. 83 g GL100 series Product Information - Page 30 - Overseas Sales and Marketing Dep.

GL100 series Specifications (Input module 8) Dual port adapter (GS-DPA) Item Number of sensors Connectable sensors Length of cable Operating environment External dimension [W x D x H] Weight Two (2) sensors GS-TH (Temp./Humidity), GS-CO2 (Carbon dioxide (CO2)), GS-LXUV (Illuminance & Ultraviolet) It is not able to connect two sensors of the same type. Approx. 200 mm Temperature: -10 ºC to 50 ºC Humidity: up to 80 % RH (non condensed) Approx. 46 x 66 x 27 mm (exclude protrusion) Approx. 68 g Module Extension Cable (GS-EXC) Item Connectable input module Length of cable Operating environment All types of input module Cable is connected between the input module and the GL100. Approx. 1.5 m Temperature: -10 ºC to 50 ºC Humidity: up to 80 % RH (non condensed) GL100 series Product Information - Page 31 - Overseas Sales and Marketing Dep.

GL100 series Product line-up (1) Main body Item PetitLOGGER GL100 Model number GL100-N Main body without Wireless LAN Input module and Accessories Item Model number Temp./Humidity Sensor GS-TH Sensor of Temperature (-20 to 85 ºC) and Humidity (0 to 100 % RH) Acceleration/Temp. Sensor GS-3AT Sensor of Acceleration (up to 10 G), Temperature (-10 to 85 ºC) Voltage/Temp. Input terminal GS-4VT Input terminal of Voltage (20 mv to 50 V), Thermocouple (K/T) Thermistor Input terminal GS-4TSR Input terminal of Temperature (Thermistor -40 to 120 ºC) Thermistor Sensor (Normal type) GS-103AT-4P Sensor for GS-4TSR module, 3 m long, 4 pcs/set, Temp.: -40 to 105 ºC Thermistor Sensor (Ultrathin type) GS-103JT-4P Sensor for GS-4TSR module, 3 m long, 4 pcs/set, Temp.: -40 to 120 ºC Illuminance/UV Sensor GS-LXUV Sensor of Illuminance ans UV intensity Carbon dioxide (CO2) Sensor GS-CO2 Sensor of Carbon dioxide (CO2) (up to 9999 ppm) AC Current Sensor GS-AC50A For GS-DAP-Ac module, Cable 200 mm, Current: 50 A AC AC Current Sensor GS-AC100A For GS-DAP-AC module, Cable 200 mm, Current: 100 A AC AC Current Sensor GS-AC200A For GS-DAP-AC module, Cable 200 mm, Current: 200 A AC AC Current Sensor Adapter GS-DPA-AC Adapter of AC Current sensor (Two sensors are able to connect) Dual port adapter GS-DPA Connect up to two (2) sensors Module Extension Cable GS-EXC Extension cable for input module, 1.5 m long GL100 series Product Information - Page 32 - Overseas Sales and Marketing Dep.

GL100 series Product line-up (2) Line-up includes combined models best suited for application base GL100 will feature combo solutions that are packaged together and will be offered as a one stop solution as an out-of-the-box-ready item for the specific application that best fits your need. Item Model number 1 GL100-N-TH GL100-N (without WLAN) with GS-TH (Temp./Humidity) 2 GL100-N-3AT GL100-N (without WLAN) with GS-3AT (Acceleration/Temp.) 3 GL100-N-4VT GL100-N (without WLAN) with GS-4VT (Voltage/Temp.) 4 GL100-N-4TSR GL100-N (without WLAN) with GS-4TSR (Thermistor) ( * 1) Note; *1: The thermistor sensor is not included. GL100 series Product Information - Page 33 - Overseas Sales and Marketing Dep.

Packaging Packaging of the GL100 series GL100 main body or the input module (GS-xx series) is packed in the following box. GL100 or Input module (GS series) or Combo model (GL100 + module) Size (W x D x H): Approx. 170 x 170 x 70 mm Gross weight: up to 400g (varies by the item) (One set of GL100 including the accessories is packed, or one set of input module including the accessories is packed, or one set of combo model (GL100 + Input module) including the accessories is packed.) Shipping container of the GL100 Four (4) of packaged box for the GL100 are packed to this shipping container. Size (W x D x H): Approx. 170 x 350 x 140 mm Gross weight: up to 1.7 kg (varies by the item) (Four (4) boxes of GL100 or the input modules are packed in this container. The same item is packed. It is not able to mix the different items.) GL100 series Product Information - Page 34 - Overseas Sales and Marketing Dep.

Proposing solutions using GL100 Combination of the GL100-N and the Industry-specific application software Measuring Temperature Accumulation Amount of solar radiation Confirm temperature accumulation, humidity deficit, solar radiation, ultraviolet rays as part of the vital indicators for healthy plant growth. Measure optimal saturation deficit by understanding the best conditions applied for growth, flowering, and fruiting using temperature accumulation and optimal growth environment analysis. Farm Agricultural application GL100 (Temp./Humidity) Humidity Deficit Amount of ultraviolet rays GL100 (Carbon dioxide (CO2)) Greenhouse GL100 (Illuminance) Logistics (transport) application Combination of the GL100-N and the Industryspecific application software Measuring Search and display acceleration thresholds Temperature Accumulation Humidity Deficit Transpiration of industrial equipment, temperature controlled transport of food, and warehouse temperature management can all be monitored to provide the safest and secured operation. Safety measurements through monitoring the vibration of the transport vehicles can be vital to heavy-industrial and vibration sensitive equipment. Accumulated temperature monitoring and humidity levels will be vital to keeping food fresh in a controlled environment. Vibration In the cargo Cargo room On bed of cargo room Temperature /Humidity PC with Software for Agricultural USB HUB GL100 (Temp./Humidity) Acceleration /Temp. Checking data in Office or Warehouse Acceleration /Temp. micro SD Memory card Search and display acceleration thresholds The time and value that acceleration exceeds the threshold are displayed in the list. Threshold (x.x G) Vibration PC with Software for Logistic GL100 series Product Information - Page 35 - Overseas Sales and Marketing Dep.