Models: LED-8088M40/LED-8088M40C,LED-8088E40/LED-8088E40C,LED-8088M57 /LED-8088M57C,LED-8088E57/LED-8088E57C

Similar documents
DRAFT. Models: LED-8085M30, LED-8085M30C; LED-8085M42, LED-8085M42C; LED-8085M57, LED-8085M57C

In Situ Temperature Measurement

In Situ Temperature Measurement Test Report. For. AOK LED Light Company Limited. (Brand Name: ) Outdoor Pole/Arm-Mounted Area and Roadway Luminaires

NVLAP LAB CODE In Situ Temperature Measurement Test Report. For. AOK LED Light Company Limited. (Brand Name: AOK)

NVLAP LAB CODE In Situ Temperature Measurement Test Report. For SHENZHEN SUNPER OPTO CO.,LTD. (Brand Name: SUNPER)

NVLAP LAB CODE For. Shen Zhen Green Works Lighting Co., Ltd. Floor 4, Bldg. A, No. 36-8, Yingtai Road,Dalang, Longhua, SHENZHEN,China.

NVLAP LAB CODE ISTMT Test Report. For IROCO AOTOM (HUBEI) PHOTOELECTRICITY CO., LTD

Technical-Report for SL Lamp 5 W

REPORT 3933 US ROUTE 11, CORTLAND, NEW YORK 13045

REPORT Dialight, 1501 Route 34 South, Farmingdale, NJ 07727

REPORT COMMERCENTRE DRIVE, LAKE FOREST, CA 92630

Energy Star Directional Luminaire Test Report ELEC-TECH INTERNATIONAL CO LTD. LED Downlight

REPORT 545 E. Algonquin Rd., Arlington Heights, IL 60005

REPORT COMMERCENTRE DRIVE, LAKE FOREST, CA 92630

REPORT COMMERCENTRE DRIVE, LAKE FOREST, CA 92630

REPORT 3933 US ROUTE 11 CORTLAND, NEW YORK 13045

REPORT 545 E. Algonquin Rd., Arlington Heights, IL 60005

REPORT COMMERCENTRE DRIVE, LAKE FOREST, CA 92630

REPORT COMMERCENTRE DRIVE, LAKE FOREST, CA 92630

ENERGY STAR Program Requirements

REPORT 545 E. Algonquin Rd., Arlington Heights, IL 60005

REPORT 545 E. Algonquin Rd., Arlington Heights, IL 60005

DRD5S & SurfaceFrame Alt/EM Surface Mount LED Downlight

EN 60529:1991+A1:2000+A2:2013 Measurement and Test Report

DRD5S & SurfaceFrame Alt/EM 18" Linear Surface Mount LED Area Light

Safety Certification of Solid-State Lighting Products. September 23, 2009 Todd Straka Director - Lighting Services

FPLHB - Fidelux Premier Linear Highbay

UL TEST REPORT AND PROCEDURE

RF TEST REPORT. ZTE Corporation SRQ-VFD510 ZTE LTE/WCDMA/GSM GPRS RXC RF07

The product and any acceptable variation thereto is specified in the Annex to this certificate and the documents therein referred to.

Lamp Circuit Power Test Report

Refrigerating Appliance ErP Test Report

ETL Testing Laboratories, Inc.

Certification Supplement Manual

Albeo LED Luminaire. Heavy Industrial Low Bay Lighting. (ALR1 - Series)

Test Report No. AJHG FB Date: FEB.17, 2015 Page 1 of 13

SECTION INTERIOR LIGHTING

LED Reliability and Current Standards for Measurement

Project Name. Date. Cat. Number. Type

TEST REPORT IEC Safety of laser products - Part 1: Equipment classification and requirements

Kräftigled Catalogue 2016

Energy Solutions LED Accelerator Program PRODUCT QUALIFICATION REQUIREMENTS 2015

LED Linear Design Highlights

Product Compliance Andy Guest

THE HIGH STRIP FIXTURE SERIES PERFORMANCE KEY FEATURES INCLUDE: LED Fixture Series for General, Direct and Indirect Illumination

Designed by TD lighting Solutions in Turkey, Powered by Nichia LEDs from Japan

REPORT NUMBER: MID-003r1 ORIGINAL ISSUE DATE: March 11, 2015 Revised Date: March 20, 2015

Rating. Class I Div II

OLUX LED Flood Light OSRAM. Datasheet APPLICATIONS.

TEST REPORT IEC Safety of household and similar electrical appliances Part 2: Particular requirements for massage appliance

THE HIGH STAIRWELL AND PASSAGEWAY FIXTURE PERFORMANCE KEY FEATURES INCLUDE:

Fortimo LED Line Gen2 Module

Dimensions (111mm) 3 (76mm) (111mm) (48mm)

Dimensions (111mm) (111mm) 3 (76mm)

led HIGH CEILING 3 OUTPUT LEVELS LL1 - Low Output: 49W LL2 - Medium Output: 69W LL3 - High Output: 100W

Navigating the Safety Certification Process for LED Lighting Products Todd Straka, Director Lighting Services

INSTALLATION INSTRUCTIONS WARNINGS AND INSTRUCTIONS FOR LUMINAIRES

E10 & L9 Low Wattage Light Cone Data

Alliance 4 - ALI4 LED 4 Linear High Bay

German Of ce. New Construction Plan

THE HIGH STAIRWELL AND PASSAGEWAY FIXTURE PERFORMANCE KEY FEATURES INCLUDE:

LUXCOMFO TM LED Flood Light Datasheet

RECESSED - WITH StepLens OPTION

Fortimo LED Line High Flux Module

LED RETROFIT CONVERSION KITS

4SNLEDLD548SLUNV 4snledld548slunvl840cd1u

LHBXD LED Linear High Bay

SGS-CSTC Standards Technical Services (Shanghai) Co., Ltd. FCC MPE REPORT

Certification Supplement Manual

HEP Tech Co., Ltd. Company Profile

2016 Title 24, Part 6 Reference Joint Appendices JA8 & JA10 Residential Lighting Test, Certify, & Comply

Step-Dimming and/or 0-10v Dimming Drivers Electro Galvanized Steel Welded Construction. Photocell Sensor - On/Off Stainless Steel Fasteners Standard

LHB LED High Bay. Technical Specifications. Description. Performance Data. Dimensions & Weights. Delivered Lumens Efficacy.

OLUX LED IN-GROUND OSRAM. Datasheet

SDL4 LED Strip Diffused Lens

MEASUREMENT AND TEST REPORT

BAS SDL8' LED Strip Diffused Lens

LED Shoplight fixture

IEC60601_1J. Medical electrical equipment Part 1: General requirements for basic safety and essential performance

Lighting Measurement Solutions

SIMPLIFIED LIGHTING. TRUSTED PROTECTION. CODE MASTER LED LUMINAIRES CLASS I, DIVISION 1

Test Report. No. CANHG A01 Date: 31 Jul Page 1 of 6.

T8 Self Ballasted UL & CSA LED TUBE RETROFITS

CE EMC Test Report EN :2015 EN :2017. Folder with powerbank ZKS E. Lieber Ouyang (Engineer) Lahm Peng (Manager)

BAS SFP22 Edge-lit LED Panel

Affordable and reliable energy saving LED Lighting Luminaires

Energy Efficient Lighting Systems

Capella 2. Project Name. Construction. Optical System. Product Applications. Housing and lens frame are constructed from heavy-duty low

FCC COMPLIANCE REPORT. SHENZHEN STARWELL TECHNOLOGY CO., Ltd. AC/DC ADAPTER

HIGH LUMINOUS EFFICIENCY

CPPG ENERGY EFFICIENT CANOPY LIGHTS FOR PARKING AREAS

HDL106 LED LUMINAIRES. For Harsh & Hazardous Environments.

INSTRUCTIONS FOR SAFE OPERATIONS LM3000 EXPLOSION PROOF LASER DISTANCE METER

UL TEST REPORT AND PROCEDURE

TYPE APPROVAL CERTIFICATE

DOWNLIGHT 800/1200/1500 LUMEN ROUND APERTURE REMODEL AX2 DR

Fahrenheit Recessed LED Downlight Fire and Sound-Rated New Construction 4, 5, 6 Aperture

Project Name. Date. Cat. Number. Type

Application for FCC Certificate On Behalf of. TTE Technology, Inc. LCD TV or LED TV. Model Number: 55R80 FCC ID:W8U55R80

ENERGY STAR Program Requirements for Residential Light Fixtures. Eligibility Criteria Version 4.2. Table of Contents

Transcription:

IESNA SUSTAINING MEMBER Ref. No.: LCGP15060198 Dateof issue July 22,2015 Version 1.0 Total pages: 10 Test report of In Situ Temperature Measurement And Lumen Maintenance Projection Rendered to: LIGHT EFFICIENT DESIGN, DIV OFTADD LLC 188 S. Northwest Highway Cary, IL 60013 For products: LED Lamp Models: LED-8088M40/LED-8088M40C,LED-8088E40/LED-8088E40C,LED-8088M57 /LED-8088M57C,LED-8088E57/LED-8088E57C Test date: June 26, 2015 Test laboratory: Laboratorynote: Complied by: Bowen Pang Test Engineer LCTECH (Zhongshan) Testing Service Co.,Ltd 2/F.,Technology and Enterprise Development Center, Guangyuan Road, Xiaolan, Zhongshan, Guangdong, China LED-8088M40,LED-8088M40C,LED-8088E40,LED-8088E40C and LED-8088M57,LED-8088M57C,LED-8088E57,LED-8088E57C is all the same except from lamp base and CCT, model LED-80888M40,LED-8088M40C was selected as the representative test sample. Reviewed by: Richard Li Technical Manager July22, 2015 July22, 2015 The duplication of this report or parts of it and its use for advertising purposes is only allowed with permission of thetestinglaboratory. This reportcontainstheresult of theexaminationofthe product sample submitted by the applicant. A general statement concerning the quality of the products from the seriesmanufacturecannot be derivedtherefore. Thisreportmust not beused bythecustomer to claim productcertification, approval or endorsementby NVLAP, NIST, or any agency of thefederal Government.

Page2of 10 Table of Contents 1 General... 3 1.1 Product Information... 3 1.2 Reference standards or methods... 4 1.3 Equipment list... 4 2 Test conducted and method... 5 2.1 Ambient Condition... 5 2.2 Temperature Stabilization... 5 2.3 Thermocouples... 5 2.4 Draught-free test enclosure... 5 2.5 Mounting methods... 5 2.6 Thermocouples contact... 5 3Test Result... 6 3.1 Electrical data... 6 3.2 Temperature data... 6 3.3 Lumen Maintenance Projection (IESNA TM-21 Method)... 6 3.4 Thermocouple contact photo... 6 Appendix1LM-80 report summary... 7 Appendix2TM-21 inputs... 8 Appendix3TM-21 Results... 9

1 General Page3of 10 1.1 Product Information Brand Name Light Efficient Design Trade Mark - Lamp Type LED Lamp LED-8088M40/LED-8088M40C, Model Number LED-8088E40/LED-8088E40C, LED-8088M57/LED-8088M57C, LED-8088E57/LED-8088E57C Rated Inputs 120-347V,50/60Hz Rated Power 50W Rated Initial Lamp Lumens 6000lm, LED-8088M40/LED-8088M40C, 4000K; Declared CCT LED-8088E40/LED-8088E40C, 4000K; LED-8088M57/LED-8088M57C, 6500K; LED-8088E57/LED-8088E57C, 6500K Power Supply Integral LED driver LED Package, Array or Module No Provide Date of Receipt Samples June 18, 2015 Quantity of Receipt Samples 1unit Photo Picture 1 Picture 2

Page4of 10 1.2 Reference standards or methods Thefollowing standards are partly or totally used or referenced for test: No. ANSI/UL 1598:2008 (Secs. 19.7, 19.10-16) IES LM-80-08 IES TM-21-2011 Name Luminaires Approved Method for Measuring Lumen Maintenance of LED Light Sources Projecting Long Term Lumen Maintenance of LED Sources 1.3 Equipment list ID Instrument Model name Cal.date Next cal. Date AC Power supply LC-I-923 CHP-500 2015-02-05 2016-02-04 AC Power supply LC-I-987 APW-110N 2015-02-05 2016-02-04 Power analyzer LC-I-928 WT210 2015-02-09 2016-02-08 Power analyzer LC-I-954 WT210 2015-03-04 2016-03-03 Multimeter LC-I-972 Fluke17B 2014-08-15 2015-08-14 J thermocouple LC-I-096 TT-J-30-SLE(200m/r) 2015-02-19 2016-02-18 Data acquisition/switch LC-I-098 34970A 2015-02-12 2016-02-11 unit T&H recorder LC-I-903 WS-1 2015-03-01 2016-03-01

2Test conducted and method Page5of 10 2.1 Ambient Condition Test was conducted in an ambient temperature of 25 5 C. Ambient temperature variations aboveor below 25 Cwas subtractedfrom or added totemperatures recorded at points on the luminaire. The ambient temperature was measured by a thermocouple which was immersed in 15ml of mineral oil in aglass container. 2.2 Temperature Stabilization Temperatures were measured afterthey have stabilized when the temperature were changing at arate less than 1 Cper hour and would not rise. 2.3 Thermocouples Type Jthermocouple was used for temperature measurement. The diameter of thermocouple conductor was 0.05mm 2. 2.4 Draught-free test enclosure The luminaire was positionedin arectangular draught-proof enclosure with adouble skin on the top and on at least three sides, and with asolid base. The double skins were of perforated metal, spaced apart approximately150mm, with regular perforationsof 1mm to2mm diameter, occupying about 40% of the whole area of each skin. The internal surfaces of enclosure are painted with amatt paint. 2.5 Mounting methods The luminaire was mounted on adesignated bracket for flood luminaires or road luminaires. 2.6 Thermocouplescontact Thermocouples were in contact with the TMP LED location described in LM-80 test report. In order to gain the maximum temperature, if appropriate, more than one thermocouple was contact in these locations. For details information, please refer to clause 3.4 for the photo of thermocouple contact.

3Test Result 3.1 Electrical data Page6of 10 Criteria Item Result Input voltage 277.02 V~60Hz Input current 0.211 A Total power 52.50W Power factor 0.896 3.2 Temperature data Criteria Item Total operated period(hours) Ambient temperature Measured maximum Temperature @TMP LED Maximum Temperature @TMP LED (Normalized to 25 C) Result 4.2 hours 25.5 C 80.6 C 80.1 C 3.3 Lumen Maintenance Projection (IESNATM-21Method) Criteria Item Result 6000 hours lumen maintenance of LED light source 96.23% Drive current on each LED light source 150 ma Projected L 70 lumenmaintenance life 44000 hours Reported L 70 lumen maintenance life >36000 hours Note: Please refer to appendix 2and 3for details oftm-21inputs and results. 3.4 Thermocouple contact photo

Page7of 10 Appendix 1LM-80 report summary Report originated by Guangzhou Hongli Opto-Electronic Co., Ltd.. Manufactured by Guangzhou Hongli Opto-Electronic Co., Ltd. LM-80 report No. RSZ120424502-10-M4 LED Model HL-A-2835DW-S1-08-HR3 LED Part Number HL-A-2835DW-S1-08-HR3 Number of LED light source tested 25 units Drive Current 150 ma Case temperature 75 C 85 C 6000 hours lumen maintenance 96.95% 95.19% 6000 hours color 0.0009 0.0011 maintenance( u v )

Page10of 10 (This page isintentionally left in blank) ****End of test report****