Packaged Heat Pump. 20 Ton Rooftop Units with ReliaTel TM Controls NOTICE

Similar documents
Packaged Cooling 20 Ton Rooftop Units with ReliaTel Controls, 50 Hz

4A6H5049E1000B 208/230/1/ /8 7/8 7/8 7/8 DURATION 208/230/1/ /230/1/ SPINE FIN 13 LBS., 10 OZ. YES

Packaged Rooftop Air Conditioners Precedent - Cooling, Gas/Electric, Heat Pump 3-5Ton Standard and High Efficiency 3 Phase Rooftop Units

208/230/1/60 5/8 5/8 5/8 5/8 5/8 20 CLIMATUFF /230/1/

4A6H5042G1000A 208/230/1/ DURATION - SCROLL 3/4 208/230/1/ NO (Use BAYKSKT263) YES YES PROPELLER DIRECT

208/230/1/ CLIMATUFF /230/1/ YES NO NO PROPELLER 23-1 DIRECT / /230/1/ SPINE FIN

Service Facts. WARNING: HAZARDOUS VOLTAGE - DISCONNECT POWER and DISCHARGE 4TTR6048-SF-1A. Split System Cooling 4TTR6048A1000A CAUTION CAUTION WARNING

Service Facts. WARNING: HAZARDOUS VOLTAGE - DISCONNECT POWER and DISCHARGE 4TTB6-SF-3. Split System Cooling 4TTB6048A1000A, 4TTB6049A1000A CAUTION

7/8 NO NO NO PROPELLER DIRECT / /230/1/ SPINE FIN /8 8 LBS., 0 OZ. YES 7/8 3/8

Service Facts. WARNING: HAZARDOUS VOLTAGE - DISCONNECT POWER and DISCHARGE 4TTR6024-SF-1B. Split System Cooling 4TTR6024A1000B CAUTION CAUTION WARNING

Service Facts. Split System Cooling 3.0 Ton 4A7A6036J-SF-1B-EN. January A7A6036J1000A

4TTB3030D1000B 208/230/1/60 4TTB3036D1000B 208/230/1/ RECIP /230/1/ RECIP YES YES

4TTR6036B1000A 208/230/1/ CLIMATUFF - SCROLL 3/4 3/4 3/4 3/4 3/4 208/230/1/ NO YES NO PROPELLER DIRECT

4TTB3060D1000B 208/230/1/60 35 SCROLL /230/1/ /8

Packaged Heat Pumps. Voyager 12½ to 20 Tons 60 Hz PKGP-PRC001-EN. September 2004

Packaged Cooling with Electric Heat Rooftop Units

Product Data /4WCC3018A through 2/4WCC3060A Single Package Convertible Heat Pump 13 SEER 1½ - 5 Ton R-22/R-410A

Packaged Cooling with Electric Heat Rooftop Units

Packaged Gas/Electric Rooftop Units

36,000-62,000 BTUH Nominal Capacity

MIN. CCT. QTY RLA LRA HP FLA AMPACITY /1/ /3/

PAD3. Product Specifications. 13 SEER PACKAGE AIR CONDITIONER, 2 to 5 TONS Single Phase, 208/230 V, 60 Hz REFRIGERATION CIRCUIT

Service Facts. Air Handler - Convertible Model: Series 2 Air Handlers ton GAT2A0B42S31SA GAT2A0C48S41SA GAT2A0C60S51SA WARNING: GAT2-SF-1B

CAS. Product Specifications. COMMERCIAL SPLIT SYSTEMS CONDENSING UNITS R 410A, 6 to 12.5 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE

Split System Heat Pumps

FLD = Furnished by Trane U.S. Inc. / Installed by Equipment Submittal Page 3 of 13

2 Ton Convertible Air Handler TAM7A0A24H21SD Standard Coil TAM7A0A24H21EA Black Epoxy Coil

TECHNICAL GUIDE. Description SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS YD360, 480 & THRU 50 NOMINAL TONS YTG-B-0811

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS. HA300, HB360, HB480 & HB thru 50 NOMINAL TONS (50 Hz)

Technical Guide SUNLINE 2000 DESCRIPTION ACCESSORIES FIELD INSTALLED SPLIT-SYSTEM EVAPORATOR BLOWER K4EU NOMINAL TONS (WORLD 50 HZ)

Service Facts. Split System Heat Pump 4A6H5019H-SF-1C-EN. August A6H5019H1000A

Product Data. Features/Benefits. GEMINI 38AKS Commercial Air-Cooled Split Systems 50/60 Hz. 25 to 40 Nominal Tons (82.8 to 127.

DSV Model Air Cooled Self Contained Indoor Packaged Units 3-5 Tons Preliminary Application Data

Commercial High-Efficiency Condensing Units

PAJ3. Product Specifications

Product Data. Features/Benefits. 38AH Commercial Air-Cooled Condensing Units 50/60 Hz. 20 to 130 Nominal Tons (63 to 390 Nominal kw)

Submittal. 1 1/2 Ton Convertible Air Handler TEM3A0B18S21SA TEM3A0B18-SUB-1C-EN. July 2014 TAG:

Submittal. 2 Ton Convertible Air Handler TEM3A0B24S21SA TEM3A0B24-SUB-1C-EN. July 2014 TAG:

Submittal. 5 Ton Convertible Air Handler TEM3A0C60S51SA TEM3A0C60-SUB-1C-EN. July 2014 TAG:

FF1DNA, FF1DNE FAN COIL UNITS. Sizes 018, 024, 030. Form No. PDS FF1D.18.3 FEATURES FF1D

R-410A AFFINITY SERIES DEX DEY Ton

K*ES120 DESCRIPTION TECHNICAL GUIDE SPLIT-SYSTEM EVAPORATOR BLOWERS 10 NOMINAL TONS EER 8.5 ACCESSORIES FIELD INSTALLED TABLE 1: ARI RATINGS*

PHD3. Product Specifications

PAR5. Product Specifications

Technical Development Program. COMMERCIAL HVAC PACKAGED EQUIPMENT Split Systems PRESENTED BY: Ray Chow Sigler

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 FEATURES B-0703

INSTALLATION INSTRUCTIONS

Packaged Rooftops. Voyager, R-410A. 12½ - 25 Tons 60 Hz. Packaged Cooling (TC*) Packaged Gas/Electric (YC*) RT-PRC028-EN.

Advance Release September 2009

PACKAGE AIR CONDITIONER

Split System Cooling Units

TECHNICAL GUIDE LISTED. SPLIT-SYSTEM AIR CONDITIONERS 10 SEER R22 60Hz MODELS: AC036X10(3,4) THRU 060 (3 THRU 5 NOMINAL TONS, 3 PH) DESCRIPTION

EER PACKAGE AIR CONDITIONER, 6.9 to 14.4 kw, 2 4 TONS 3 Phase, Standard CFM / Ls EER

14 SEER, 12 EER, 8.0 HSPF, PACKAGE HEAT PUMP, 2 to 5 TONS 208/ , Single Phase

UP to 14.5 SEER, PACKAGE AIR CONDITIONER UNIT, 2 to 5 TONS 208/230 Volt, 1 phase, 60 Hz REFRIGERATION CIRCUIT

Variable Speed Convertible Air Handler 5 Ton

Ameristar SUBMITTAL M4AH4E26B1A00AA. 2.0 Ton Multi-position Air Handler M4AH4E26B1A00AA TAG:

Multi-position, Upflow, Horizontal Left, or Horizontal Right, Modular Air Handlers

High Heat COP. High/Low Stage

Product Data. 50HS Single-Package Heat Pumps to 5 Nominal Tons

TECHNICAL GUIDE LISTED. SPLIT-SYSTEM AIR CONDITIONERS 10 SEER R22 60Hz MODELS: H*BA-(T,W)036 THRU 076 (3 THRU 6.3 NOMINAL TONS, 3 PH) DESCRIPTION

Technical Guide DESCRIPTION CHAMPION SPLIT-SYSTEM EVAPORATOR BLOWER L4EU240A 20 NOMINAL TONS (WORLD 50 HZ) FEATURES XTG-A-0307

LGH/LCH WARNING. CAUTION Danger of sharp metallic edges. Can cause injury. Take care when servicing unit to avoid accidental contact with sharp edges.

Packaged Heat Pumps. Precedent - R Tons 60 Hz. Packaged Heat Pumps (WSC) PKGP-PRC003-EN. November 2008

THE WALL-MOUNT ONE TON AIR CONDITIONER. Green Refrigerant. 12,000 Btuh EER Right Side Control Panel. Engineered Features

EMBASSY SERIES SINGLE PACKAGE AIR CONDITIONERS (WATER-COOLED) C2ED060, 090, 120 & 180 5, 7-1/2, 10 & 15 Nominal Tons

SPLIT-SYSTEM EVAPORATOR BLOWER DESCRIPTION FEATURES L4EU NOMINAL TONS

Y_C-SVE002B-EN. Wiring Manual. Packaged Gas/Electric with ReliaTel Controls 3-10 Tons. Models: (60 Hz) YSC036A*R - YSC120A*R YHC033A*R - YHC120A*R

VertiCool Aurora Engineering Guide

Submittal. Split System Cooling 5.0 Ton 4A7A3060D1000P TAG:

Split System Heat Pump Product Data

C13-Series Engineering Guide

Product Catalog. Packaged Rooftop Air Conditioners Foundation Electric/Electric Tons, 50 Hz RT-PRC073B-EN. May 2018

Packaged Heat Pumps. Precedent - R-410A Tons 60 Hz. Packaged Heat Pumps (WSC) PKGP-PRC013-EN. August 2009

Submittal. Split System Cooling 4A7A6024J-SUB-1B-EN. January A7A6024J1000B TAG:

Product Catalog. Packaged Rooftop Air Conditioners Foundation Electric/Electric 3 to 5 Tons, 50Hz RT-PRC079B-EN. June 2017

Cooling/Heat Pump Convertible Air Handlers

R-410A AFFINITY SERIES

THE WALL-MOUNT ONE TON AIR CONDITIONER GREEN REFRIGERANT R-410A. 10,800 Btuh 9.00 EER Right Side Control Panel. Engineered Features

COMMERCIAL AIR HANDLER

Product Data. 4WCY4024A through 4WCY4060A Single Packaged Convertible Heat Pump 14 SEER 2-5 Ton R-410A Trane Pub. No.

INSTALLATION MANUAL AFFINITY SERIES SINGLE PACKAGE AIR CONDITIONERS ELECTRIC/ELECTRIC, AIR-COOLED. MODELS: D1EB036 thru Thru 5 Ton (10 SEER)

Split System Cooling Product Data

TECHNICAL GUIDE GENERAL SPECIFICATIONS COMMERCIAL SPLIT-SYSTEM COOLING UNITS FOUR PIPE SYSTEM OUTDOOR UNIT: INDOOR UNIT:

Technical Guide DESCRIPTION ACCESSORIES FIELD INSTALLED SPLIT-SYSTEM EVAPORATOR BLOWERS. 7-1/2 and 10 NOMINAL TONS LA090 & LA120 SUPPLY AIR PLENUMS

2YCC3060A1120A /1/ / YCC3060A1096A /1/ /

4YCC3048A3096A /3/ /

Modular Multi-position Air Handler

Packaged Cooling & Gas/Electric Rooftops. Voyager. 12½-25 Tons 60 Hz. Packaged Cooling (TC*) Packaged Gas/Electric (YC*) RT-PRC024-EN.

TECHNICAL GUIDE SPLIT-SYSTEM AIR-COOLED EVAPORATOR BLOWER 25, 30, 40 & 50 TON LA300, LB360, 480 & 600 (50 Hz) PROVEN PERFORMANCE GENERAL FEATURING

PRODUCT SPECIFICATIONS 2YCC3048A1120A /1/ /

Variable Speed Convertible Air Handler 4 Ton

1-1/2 THRU 2-1/2 TONS SPLIT SYSTEM FWM Series

Split System Heat Pump Product Data

CHAMPION SPLIT-SYSTEM EVAPORATOR BLOWER DESCRIPTION FEATURES L2EU NOMINAL TONS

14 SEER, 12 EER, 8.0 HSPF, PACKAGE HEAT PUMP, 2.5 to 5 TONS 208/ , Operating Model Number

Product Data. Fig. 1 - Unit 50VR -A

PRODUCT SPECIFICATIONS 2YCC3036A1096A /1/ /

SPLIT-SYSTEM EVAPORATOR BLOWERS K2EU060, K4EU090, K3EU120 & K1EU180 5 Thru 15 Nominal Tons DESCRIPTION ACCESSORIES FIELD INSTALLED

GREEN REFRIGERANT R-410A

Transcription:

Service Facts Customer Property: Contains wiring and service information. Please retain. WC*240-SF-1H Library Service Literature Product Section Unitary Product Package Air Conditioner Model WC* Literature Type Service Facts Sequence 1H Date April 2003 File No. SV-UN-RT-WC*240-SF-1H 4/03 Supersedes NEW Models : WCD240B300GA WCD240B30AGA WCD240B30BGA WCD240B30CGA WCD240B30FGA WCD240B30GGA WCH240B300GA WCH240B30BGA WCH240B30FGA Packaged Heat Pump 20 Ton Rooftop Units with ReliaTel TM Controls NOTICE Warnings and Cautions appear at appropriate locations throughout this manual. Read these carefully WARNING: Indicates a potentially hazardous situation which, if not avoided, could result in death or serious injury. CAUTION: Indicates a potentially hazardous situation which, if not avoided, may result in minor or moderate injury. It may also be used to alert against unsafe practices and where property-damageonly accidents could occur. Since the manufacturer has a policy of continuous product improvement, it reserves the right to change design and specifications without notice. Page F-727

Product Specifications VOLTS/ PHASE/ HZ 208-230/ 3/ 60 VOLTS/ PHASE/ HZ 208-230/ 3/ 60 A.R.I. Ratings INDOOR FAN Cooling Net Cap. BTUH (1) Type/ No. Used FC Centrifugal/ 1 Downflow/ Horizontal 222,000 / 224,000 Dia. x Width (Inches) 18" x 18" Part Load Drive/ No. Speeds Belt/ Variable Downflow/ Horizontal 104,000 INDOOR FAN MOTOR IPLV (4) Motor HP/ RPM Downflow/ Horizontal 9.7 / 10.3 Standard Motor 5.0/ 3450 Indoor Air Flow (CFM) Oversize Motor 7.5/ 3470 Downflow/ Horizontal 8,000 / 7,000 System Power (KW) Volts/ Ph/ Hz 208-230/ 3/ 60 Downflow/ Horizontal 22.2 / 21.3 L.R. Amps/ F.L. Amps EER (BTU per Watt) (2) Standard Motor 109.8/ 16.7 Downflow/ Horizontal 10.0 / 10.5 Oversize Motor 130.3/ 24.2 Mechanical Heating Capacity BTUH OUTDOOR FAN High Temperature @ 47 F Type/ CFM Propeller/ 13,800 Downflow/ Horizontal 208,000 / 204,000 No. Used/ Diameter 2/ 26 System Power (KW) Drive/ No. Speeds Direct/ 1 Downflow/ Horizontal 19.65 / 19.29 No. Motors/ HP/ RPM 2/ 1.0/ 1125 Low Temperature @ 17 F Volts/ Ph/ Hz 208-230/ 1/ 60 Downflow/ Horizontal 128,000 / 118,000 L.R. Amps/ F.L. Amps 18.3/ 5.5 System Power (KW) FILTER Furnished Downflow/ Horizontal 18.75 / 17.29 Type Throwaway POWER CONNS Filters Size Min. Circuit Ampacity (Downflow/Horizontal) 20 X 20 X 2 (4) Standard/ Oversize Motor 96 / 103 20 x 25 x 2 (4) Fuse Size - Max. (Amps) Standard/ Oversize Motor 125 / 125 REFRIGERANT Charge (Lbs. of R-22) (3) COMPRESSOR - No Used Two Circuit 1/ 2 22.0 / 21.0 Volts/ Ph/ HZ 200-230/ 3/ 60 WEIGHT (Approx. Lbs) L.R. Amps (Circuit 1/ 2) 225 Shipping/ Net 2467/ 2008 R.L. Amps (Circuit 1/ 2) 30.1 DIMENSIONS H x W x L OUTDOOR COIL TYPE Hi-Performance Uncrated (In.) 54 x 85-1/4 x 122-1/4 Rows / F.P.I. 3/ 16 Face Area (Sq. Ft.) 35.3 Tube Size (In.) 0.375 Refrigerant Control Device Expansion Valve INDOOR COIL Type Hi-Performance Rows / F.P.I. 3/ 15 Face Area (Sq. Ft.) (DF/ HZ) 26 Tube Size (In.) 0.375 Refrigerant Control Device Capillary Tube Drain Conn. Size (In.) 1" NPT Footnotes: 1. Cooling Performance is rated at 95 F ambient, 80 F entering dry bulb, 67 F entering wet bulb and nominal cfm listed. ARI capacity is net and includes the effect of fan motor heat. Base models are certified in accordance with the Unitary Large Equipment certification program, which is based on ARI Standard 340/360-93. All models tested in accordance with ARI Standard 340/360-93. 2. Rated at ARI conditions and in accordance with DOE test procedures. 3. Refrigerant charge shown is a nominal value; for a more precise value see the unit nameplate. 4. Intergrated Part Load Values is based on ARI Standard 340. Ratings are 80 F ambient, 80 F entering dry bulb, and 67 F entering wet bulb at ARI rated CFM. 2

Performance Specifications Evaporator Fan Performance External Static Pressure (Inches of Water) 0.10 0.20 0.30 0.40 0.50 0.60 0.70 0.80 0.90 1.00 CFM RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP 5 HP Standard Motor & Field Supplied Low Static Drive (1) 5 HP Standard Motor & Drive 6400 531 1.80 556 1.97 582 2.14 610 2.28 634 2.44 658 2.61 681 2.79 705 2.98 729 3.19 7200 552 2.23 576 2.16 605 2.60 631 2.81 655 3.00 678 3.18 701 3.36 722 3.55 743 3.74 763 3.94 8000 605 3.01 627 3.16 655 3.39 679 3.63 702 3.86 724 4.07 745 4.28 766 4.48 786 4.68 805 4.90 8800 648 3.83 678 4.10 705 4.35 729 4.61 751 4.87 771 5.12 791 5.36 811 5.59 830 5.81 848 6.03 9600 702 4.91 729 5.21 755 5.49 779 5.77 800 6.06 820 6.34 839 6.61 857 6.88 875 7.13 893 7.37 (2) 7.5 HP Oversize Motor & Drive External Static Pressure (Inches of Water) 1.10 1.20 1.30 1.40 1.50 1.60 1.70 1.80 1.90 2.00 CFM RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP 7.5 HP Oversize Motor & Drive 6400 753 3.39 776 3.59 799 3.80 822 4.02 844 4.24 865 4.47 886 4.69 906 4.92 925 5.16 944 5.40 7200 784 4.15 806 4.38 827 4.61 848 4.84 869 5.07 889 5.30 910 5.54 930 5.79 950 6.04 969 6.29 5 HP Standard Motor & High Static Drive Accessory 8000 824 5.11 842 5.32 860 5.55 880 5.80 899 6.06 918 6.31 937 6.56 956 6.81 974 7.07 993 7.33 8800 866 6.26 884 6.49 901 6.73 917 6.96 934 7.20 951 7.46 969 7.74 986 8.02 1004 8.30 9600 910 7.61 927 7.85 943 8.10 960 8.35 975 8.61 7.5 HP Oversize Motor & Drive Notes: Fan motor heat (MBh) = 3.15 x Fan Bhp. Data includes pressure Drop Due to Wet Coils and Filters. 1. Field Supplied Fan Sheave BK190 Required. Field Supplied Belt may be necessary. 2. 7.5 HP Oversize Motor with Field Supplied Motor Sheave 1VP50 Required. Field Supplied Belt may be necessary. 3

Performance Specifications Static Pressure Drops (Inches Water Column) Economizer Pressure Drop (Inches of W.C.) 100% Return Air 100% Outside Air CFM Downflow/ Horizontal Downflow Horizontal 4800 0.03 0.14 0.14 5600 0.04 0.17 0.17 6400 0.04 0.22 0.22 7000 0.04 0.25 0.25 7200 0.05 0.28 0.28 8000 0.05 0.31 0.31 8800 0.06 0.37 0.37 9600 0.07 0.44 0.44 10000 0.08 0.47 0.47 Motor Sheave / Fan Speed Fan Speed (RPM) Standard Motor Sheave Standard Motor & High Oversized Motor Position Motor & Sheave Static Drive & Sheave Kit 6 Turns Open 615 835 816 5 Turns Open 659 879 853 4 Turns Open 703 923 890 3 Turns Open 747 967 928 2 Turns Open 791 1011 965 1 Turn Open 835 1055 1002 Closed N/A N/A N/A Filter Pressure Drop Filter Pressure Drop (Inches of W.C.) Standard Filters Area (Sq. Ft.) Velocity (Ft. per Min.) CFM Downflow/ Horizontal Downflow Horizontal Downflow Horizontal 6400 0.07/ 0.06 25.0 27.78 256 230 7200 0.09/ 0.08 288 259 8000 0.11/ 0.09 320 288 8800 0.14/ 0.11 352 317 9600 0.16/ 0.13 384 346 Electric Heater Pressure Drop Electric Heat Static Pressure (Inches W. C.) Air Temperature Rise Three Phase Three Phase Three Phase Across Heater (1) CFM (2) 36 KW 54 KW 72 KW 36 KW 54 KW 72 KW 6400 0.06 0.08 0.10 8000 0.10 0.12 0.14 14.2 F 21.3 F 28.5 F 9600 0.14 0.17 0.20 Note: 1. Data given is for rated voltages (240, 480, 600, and 415) @ Nominal CFM. For other than rated voltages, use the following formula to calculate the appropriate correction factor; KW (new) = Volts 2 (new) x Rated KW / Volts 2 (rated) Multiply temperature rise listed for nominal CFM by the correction factor. 2. Minimum design airflow is ± 20% of nominal CFM. To calculate temperature rise for other than nominal CFM; Temp Rise = KW x 3415 / 1.08 x CFM 4

Mechanical Data Refrigerant Circuit Diagram! CAUTION CONTAINS REFRIGERANT! SYSTEM CONTAINS OIL AND REFRIGERANT UNDER HIGH PRESSURE. RECOVER REFRIGERANT TO RELIEVE PRESSURE BEFORE OPENING THE SYSTEM. Failure to follow proper procedures can result in personal illness or injury or severe equipment damage. 5

Power Schematic 6

7

Control Schematic 8

9

Connections Diagram 10

11

Sequence of Operation These units are equipped with a microelectronic control feature, which provides operating functions that are significantly different than conventional units. It is referred to as the ReliaTel Control System. The master module is the ReliaTel Refrigeration Module (RTRM). The RTRM provides compressor anti-short cycle timing functions through minimum Off and On timing to increase reliability, performance and to maximize unit efficiency. Upon power initialization, the RTRM performs self-diagnostic checks to insure that all internal controls are functioning. It checks the configuration parameters against the components connected to the system. The LED located on the RTRM module is turned On within one second after power-up if all internal operations are okay. Cooling without an Economizer When the system is in the Cool MODE, the RTRM energizes relay (K3). When the normally open (K3) contacts close, the switch over valves (SOV1 & 2) are energized. When the zone temperature rises above the cooling setpoint controlband, the RTRM energizes the (K9) relay coil on the RTRM. When the (K9) relay contacts close, the compressor contactor (CC1) coil is energized provided the low pressure control (LPC1) and high pressure control (HPC1) are closed. When the CC1 contacts close, compressor (CPR1) and the outdoor fan motor (ODM) starts provided the normally open (ODF) relay contacts are closed, to maintain the zone temperature to within ± 2 F of the sensor setpoint at the sensed location. If the first stage of cooling can not satisfy the cooling requirement, the RTRM energizes the (K10) relay coil on the RTRM. When the (K10) relay contacts close, the compressor contactor (CC2) coil is energized provided the low pressure control (LPC2) and high pressure control (HPC2) are closed. When the CC2 contacts close, compressor (CPR2) starts provided the normally open (ODF) relay contacts are closed, to maintain the zone temperature to within ± 2 F of the sensor setpoint at the sensed location. Evaporator Fan Operation When the fan selection switch is set to the Auto position, the RTRM energizes the (K6) relay coil approximately 1 second after energizing the compressor contactor coil (CC1) in the cooling mode. In the heating mode, the RTRM energizes the (K6) relay coil approximately 1 second before energizing the electric heat contactors. Closing the (K6) contacts on the RTRM energizes the indoor fan relay (F) coil to start the indoor fan motor (IDM). The RTRM de-energizes the fan relay (F) approximately 60 seconds after the cooling requirement has been satisfied to enhance unit efficiency. When the heating cycle is terminated, the indoor fan relay (F) coil is de-energized at the same time as the heater contactors. When the fan selection switch is set to the On position, the RTRM keeps the indoor fan relay coil (F) energized for continuous fan motor operation. When the unit is equipped with the optional clogged filter switch, wired between terminals J7-3and J7-4 on the ReliaTel Options Module (RTOM), the RTRM produces an analog output if the clogged filter switch (CFS) closes for two minutes after a request for fan operation. When the system is connected to a remote panel, the SERVICE LED will be turned on when this failure occurs. Low Ambient Operation During low ambient operation, outside air temperature below 55 F, the RTRM will cycle the compressor and outdoor fan motor Off for approximately 3 minutes after every 10 minutes of accumulated compressor run time. The indoor fan motor (IDM) will continue to operate during this evaporator defrost cycle (EDC) and the compressor and outdoor fan will return to normal operation once the defrost cycle has terminated and the compressor Off time delay has been satisfied. Cooling with an Economizer When the system is in the Cool MODE, the RTRM energizes relay (K3). When the normally open (K3) contacts close, the switch over valves (SOV1 & 2) are energized. The economizer is utilized to control the zone temperature providing the outside air conditions are suitable. Outside air is drawn into the unit through modulating dampers. When cooling is required and economizing is possible, the RTRM sends the cooling request to the unit economizer actuator (ECA) to open the economizer damper. The RTRM tries to cool the zone utilizing the economizer to slightly below the zone temperature setpoint. If the mixed air sensor (MAS) senses that the mixed air temperature is below 53 F, the damper modulates toward the closed position. If the zone temperature continues to rise above the zone temperature setpoint controlband and the economizer damper is fully open, the RTRM energizes the compressor contactor (CC1). If the zone temperature continues to rise above the zone temperature setpoint controlband and the economizer damper is fully open, the RTRM energizes the compressor contactor (CC2). The ECA continues to modulate the economizer damper open/closed to keep the mixed air temperature that is calculated by the RTRM. If economizing is not possible, the ECA drives the damper to the minimum position setpoint when the indoor fan relay (F) is energized and allows mechanical cooling operation. When the unit is equipped with the optional fan failure switch, wired between terminals J7-5 and J7-6 on the RTOM, the RTRM will stop all cooling functions and produce an analog output if the fan failure switch (FFS) does not open within 40 seconds after a request for fan operation. When the system is connected to a remote panel, the SERVICE LED will flash when this failure occurs. 12

Sequence of Operation Economizer Set-Up Adjusting the minimum position potentiometer located on the unit economizer actuator (ECA) sets the required amount of ventilation air. Two of the three methods for determining the suitability of the outside air can be selected utilizing the enthalpy potentiometer on the ECA, as described below: 1. Ambient Temperature - controlling the economizing cycle by sensing the outside air-dry bulb temperature. The table below lists the selectable dry bulb values by potentiometer setting. 2. Reference Enthalpy - controlling the economizer cycle by sensing the outdoor air humidity. The table below lists the selectable enthalpy values by potentiometer setting. If the outside air enthalpy value is less than the selected value, the economizer is allowed to operate. 3. Comparative Enthalpy - By utilizing a humidity sensor and a temperature sensor in both the return air stream and the outdoor air stream, the unit control processor RTRM) will be able to establish which conditions are best suited for maintaining the zone temperature, i.e. indoor conditions or outdoor conditions. The potentiometer located on the ECA is non-functional when both the temperature and humidity sensors are installed. Potentiometer Dry Enthalpy Setting Bulb A 73* 27 B 70 25 C 67 23 D 63 22 * Factory Setting Heating Operation When the system switch is set to the Heat MODE, the RTRM energizes relay (K3). When the normally open (K3) contacts open, the switch over valves (SOV1 & 2) are deenergized. When the zone temperature falls below the heating setpoint controlband, the RTRM energizes the (K9) & (K10) relay coils on the RTRM. When the (K9) relay contacts close, the compressor contactor (CC1) coil is energized provided the low pressure control (LPC1) and high pressure control (HPC1) are closed. When the CC1 contacts close, compressor (CPR1) and the outdoor fan motor (ODM) starts provided the normally open (ODF) relay contacts are closed. When the (K10) relay contacts close, the compressor contactor (CC2) coil is energized provided the low pressure control (LPC2) and high pressure control (HPC2) are closed. When the CC2 contacts close, compressor (CPR2) starts to maintain the zone temperature to within ± 2 F of the sensor setpoint at the sensed location. The RTRM Smart Recovery function monitors the rate at which the zone temperature is changing every 9 minutes during the operating heating cycle. If the zone temperature is rising at a rate greater than 6 F per hour, no additional heat is requested (auxiliary electric heat). If not, the RTRM energizes the first stage auxiliary electric heat contactor (AH) (electric heat optional). A minimum of 10 seconds Off time must have elapsed between heater cycles. If mechanical heat and first stage auxiliary heat cannot provide the 6 F recovery rate, the RTRM energizes second stage auxiliary heat contactor (BH), if applicable. The RTRM continues to monitor the rate of change and stages the electric heat Off as it determines that the mechanical heat (compressor operation) is sufficient. Demand Defrost Demand defrost is a standard feature which permits defrost whenever coil icing conditions begin to significantly reduce unit capacity. To permit defrost, the outdoor temperature must be below 52 F, coil temperature must be below 33 F, and the delta temperature F must exceed a RTRM calculated value. After 30 minutes of run time under defrost permit conditions, the RTRM initiates a defrost cycle. Upon termination of this cycle, the RTRM monitors the outdoor temperature (ODT) and the coil temperature (CT) and calculates the delta temperature F (ODT - CT). This value is stored in memory and the RTRM calculates a defrost initiate value. The RTRM continually compares the delta temperature F to the defrost initiate value. Once the delta tee reaches the initiate value, a defrost cycle is initiated. During the defrost cycle, the RTRM energizes the relay (K3), which energizes the switch over valves (SOV1 & 2) through the normally open K3 relay contacts. Then turns the outdoor fan motor (ODM) Off by de-energizing the (K8) relay, which de-energizes the (ODF) relay. The RTRM energizes the auxiliary electric heat contactor (AH) and (BH) (if applicable) if they are not operating, while maintaining compressor (CPR1) operation. The defrost cycle is terminated based on the RTRM termination temperature calculation using the outdoor temperature (ODT) + 27 F. The defrost termination temperature (DTT) will typically be between 37 F and 52 F. Emergency Heat Operation When the system selection switch is in the EM HEAT MODE, and the zone temperature falls below the heating setpoint controlband, the RTRM bypasses compressor and outdoor fan operation and energizes the K1 relay located on the RTRM. When K1 relay contacts close, the first stage auxiliary electric heat contactor (AH) is energized. If the first stage of auxiliary electric heat can not satisfy the heating requirement, the RTRM energizes the K2 relay coil located on the RTRM. When the K2 relay contacts close, the second stage auxiliary electric heat contactor (BH) is energized. The RTRM cycles both the first and second stages of heat On and Off as required to maintain the zone temperature setpoint. 13

Refrigeration Data 450 COOLING CYCLE PRESSURE CURVE (Based on Indoor Airflow of 400 CFM / Ton) ONE FAN Discharge Pressure, PSIG 400 350 300 250 200 150 68/57 F ID DB/WB 74/62 F ID DB/WB 80/67 F ID DB/WB 86/72 F ID DB/WB 65 F OD Ambient 55 F OD Ambient 45 F OD Ambient 35 F OD Ambient 100 60 65 70 75 80 85 90 95 100 Suction Pressure, PSIG COOLING CYCLE PRESSURE CURVE (Based on Indoor Airflow of 400 CFM / Ton) FULL LOAD Discharge Pressure, PSIG 475 425 375 325 275 225 175 68/57 F ID DB/WB 74/62 F ID DB/WB 55 F OD Ambient 125 45 50 55 60 65 70 75 80 85 90 95 100 105 110 80/67 F ID DB/WB Suction Pressure, PSIG 86/72 F ID DB/WB 85 F OD Ambient 75 F OD Ambient 65 F OD Ambient 115 F OD Ambient 105 F OD Ambient 95 F OD Ambient To Check Operating Pressures 1. Start the unit and allow the pressures to stabilize. 5. Plot the outdoor dry bulb and the 2. Measure the indoor DB/WB temperature indoor DB/WB temperature onto the chart. entering the indoor coil. 6. At the point of intersection, read dow n for 3. Measure the outdoor air dry bulb temperature. the suction pressure and to the left for the 4. Take discharge and suction pressure readings. discharge pressure. 14

Refrigeration Data HEATING CYCLE PRESSURE CURVE (Based on Indoor Airflow of 400 CFM / Ton) (All Points Are For 70% Outdoor Relative Humidity) 400 Discharge Pressure, PSIG 350 300 250 200 150 0 F OD Ambient 10 F OD Ambient 20 F OD Ambient 30 F OD Ambient 40 F OD Ambient 50 F OD Ambient 60 F OD Ambient 70 F OD Ambient 80 F ID DB 70 F ID DB 60 F ID DB 100 10 20 30 40 50 60 70 80 90 100 Suction Pressure, PSIG To Check Operating Pressures 1. Start the unit and allow the pressures to stabilize. 5. Plot the outdoor dry bulb and the 2. Measure the indoor DB/WB temperature indoor DB/WB temperature onto the chart. entering the indoor coil. 6. At the point of intersection, read dow n for 3. Measure the outdoor air dry bulb temperature. the suction pressure and to the left for the 4. Take discharge and suction pressure readings. discharge pressure. COMPRESSOR SUPERHEAT, DEG F 40 30 20 10 SUPERHEAT CHARGING CHART (Based on Indoor Airflow of 400 CFM / Ton) ONE CONDENSER FAN "ON" To Determine Required Superheat - A) Plot the Outdoor Temp onto the bottom axis of the curve. B) Move vertically to the appropriate indoor DB/WB temp. (or interpolate temp). C) At the point of intersection, (OD & ID) read horizontally to the left for the required superheat. 86/72 F ID DB/WB 80/67 F ID DB/WB 74/62 F ID DB/WB 0 30 40 50 60 70 80 90 OUTDOOR AMBIENT, DB F 15

Refrigeration Data COMPRESSOR SUPERHEAT, DEG F 70 60 50 40 30 20 10 SUPERHEAT CHARGING CHART (Based on Indoor Airflow of 400 CFM / Ton) BOTH CONDENSER FANS "ON" To Determine Required Superheat - A) Plot the Outdoor Temperature onto the bottom axis of the curve. B) Move vertically to the appropriate indoor DB/WB temp. (or interpolate temp). C) At the point of intersection, (OD & ID) read horizontally to the left for the required superheat. 86/72 F ID DB/WB 80/67 F ID DB/WB 74/62 F ID DB/WB 68 57 F ID DB/WB 0 35 45 55 65 75 85 95 105 115 OUTDOOR AMBIENT, DB F 1) REFRIGERANT CHARGE - ADD if the superheat is more than 5 F above curve value. - REDUCE if the superheat is more than 5 F below curve value. - OK if the superheat is within 5 F of curve value. 2) Do not add refrigerant if the superheat is less than 5 F. 3) Curves are based on 400 CFM/Ton Indoor Airflow @ 50% R.H. 4) System must be running at stablized conditions before measuring superheat. American Standard Inc. 2003 Technical Literature Printed in USA 16