Split System Heat Pump Product Data

Similar documents
Split System Heat Pump Product Data

Split System Cooling Product Data

Split System Heat Pump Product Data

Split System Heat Pump Product Data

Split System Cooling Product Data

Split System Cooling Product Data

Split System Cooling Product Data

SPLIT SYSTEM HEAT PUMP 2, 3, 4 & 5 ton HERITAGE 20 MODELS 4A6Z0024, 036, 048, & 060A. with AccuLink and Charge Assist

Split System Cooling Product Data

SPLIT SYSTEM COOLING 2, 3, 4 & 5 TON MODEL 4A7A American Standard Heating & Air Conditioning

Split System Heat Pump Product Data

Split System Heat Pump Product Data

AMERICAN STANDARD 14 MODELS 4A7B E

Split System Cooling Product Data

Split System Heat Pump Product & Performance Data

Split System Heat Pump Product Data

Split System Cooling Product Data

Split System Cooling Product Data

Split System Cooling Product Data

Split System Cooling Product Data

SPLIT SYSTEM HEAT PUMP 1½ 5 TON HERITAGE 13 MODELS 2A6H A American Standard Heating & Air Conditioning

Split System Cooling Product Data

Split System Cooling Product & Performance Data

SPLIT SYSTEM COOLING 1 1 / 2 5 TON MODELS 4A7A

Split System Cooling Product Data

SPLIT SYSTEM COOLING 1½ 5 TON ALLEGIANCE 14 MODELS 4A7A C/30-060B American Standard Heating & Air Conditioning

Appendix J Noise Appendix

Product Data. Split System Cooling A. November 2013

Product Data. Side Discharge AC Models 4TTL6018A1000A 4TTL6024A1000A 4TTL6030A1000A 4TTL6036A1000A 4TTL6042A1000A 4TTL6048A1000A 4TTL6060A1000A

Product Data. Split System Heat Pump B-EN. February A6H6024H1000A

Product Data. Split System Heat Pump D-EN. February 2016

Product Data. Split System Cooling H-EN. January 2017

Product Data. Split System Heat Pump A-EN. March 2016

Product Data. Split System Cooling E-EN. November 2016

Product Data. Split System Cooling D-EN. August 2016

Split System Cooling Product & Performance Data

Product Data. Split System Heat Pump 4TWR4018G1000A 4TWR4024G1000A 4TWR4030G1000A 4TWR4036G1000A 4TWR4042G1000A 4TWR4048G1000A 4TWR4060G1000A

Product Data. Split System Heat Pump

Product Data Split System Cooling

Hyperion TM Split Systems

Illusion Split System

Product catalog. Hyperion TM split systems 60 Hz / R410A / 13 SEER SSA-PRC009-E4

Submittal. Split System Cooling 4A7A6024J-SUB-1B-EN. January A7A6024J1000B TAG:

Submittal. Split System Cooling 5.0 Ton 4A7A3060D1000P TAG:

7/8 NO NO NO PROPELLER DIRECT / /230/1/ SPINE FIN /8 8 LBS., 0 OZ. YES 7/8 3/8

Cooling/Heat Pump Convertible Air Handlers

Service Facts. WARNING: HAZARDOUS VOLTAGE - DISCONNECT POWER and DISCHARGE 4TTR6024-SF-1B. Split System Cooling 4TTR6024A1000B CAUTION CAUTION WARNING

208/230/1/60 5/8 5/8 5/8 5/8 5/8 20 CLIMATUFF /230/1/

208/230/1/ CLIMATUFF /230/1/ YES NO NO PROPELLER 23-1 DIRECT / /230/1/ SPINE FIN

Service Facts. WARNING: HAZARDOUS VOLTAGE - DISCONNECT POWER and DISCHARGE 4TTR6048-SF-1A. Split System Cooling 4TTR6048A1000A CAUTION CAUTION WARNING

Service Facts. WARNING: HAZARDOUS VOLTAGE - DISCONNECT POWER and DISCHARGE 4TTB6-SF-3. Split System Cooling 4TTB6048A1000A, 4TTB6049A1000A CAUTION

Split System Cooling Product Data XB 1000

4TTR6036B1000A 208/230/1/ CLIMATUFF - SCROLL 3/4 3/4 3/4 3/4 3/4 208/230/1/ NO YES NO PROPELLER DIRECT

2TEH3F18A1000A 2TEH3F24A1000A 2TEH3F30A1000A 2TEH3F36A1000A 2TEH3F42A1000A 2TEH3F48A1000A 2TEH3F60A1000A 1½

4TTB3060D1000B 208/230/1/60 35 SCROLL /230/1/ /8

Cooling/Heat Pump Convertible Air Handlers

Cooling/Heat Pump Convertible Air Handlers

4A6H5042G1000A 208/230/1/ DURATION - SCROLL 3/4 208/230/1/ NO (Use BAYKSKT263) YES YES PROPELLER DIRECT

4TTB3030D1000B 208/230/1/60 4TTB3036D1000B 208/230/1/ RECIP /230/1/ RECIP YES YES

Uncased Vertical Aluminum Upflow Cooling/HP Coils 2-5 Ton 4PXA. Heat Pump / Cooling Coils for R-410A PUB. NO

Submittal. Date: January 8, Customer P.O. Number: Customer Project Number: CARROLLTON, TX 75006

4A6H5049E1000B 208/230/1/ /8 7/8 7/8 7/8 DURATION 208/230/1/ /230/1/ SPINE FIN 13 LBS., 10 OZ. YES

TruComfort Variable Speed Cooling Single Phase 2-5 Tons

Aluminum Cased Heat Pump / Cooling Coils 2-5 Ton

Service Facts. Split System Cooling 3.0 Ton 4A7A6036J-SF-1B-EN. January A7A6036J1000A

Commercial High-Efficiency Condensing Units

36,000-62,000 BTUH Nominal Capacity

UP TO 17.5 SEER / 13.5 EER / 9.5 HSPF HEAT PUMP ENVIRONMENTALLY BALANCED R- 410A REFRIGERANT 2 THRU 5 TONS SPLIT SYSTEM

TECHNICAL GUIDE. Description SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS YD360, 480 & THRU 50 NOMINAL TONS YTG-B-0811

N4H4. Product Specifications 14 SEER HEAT PUMP. ENVIRONMENTALLY SOUND R 410A REFRIGERANT 1½ THRU 5 TONS SPLIT SYSTEM 208 / 230 Volt, 1 phase, 60 Hz

PRODUCT SPECIFICATIONS 2YCC3048A1120A /1/ /

PRODUCT SPECIFICATIONS 2YCC3036A1096A /1/ /

R4H4. Product Specifications

Aluminum Cased and Uncased Heat Pump / Cooling Coils 1 1/2-5 Ton 2/4TXA, 2/4TXC PUB. NO Heat Pump /Cooling Coils for R-22 and R-410A

2YCC3060A1120A /1/ / YCC3060A1096A /1/ /

4YCC3048A3096A /3/ /

MERIT Series R-410A. SEER up to to 5 Tons Cooling Capacity - 17,500 to 59,000 Btuh AIR CONDITIONERS 13ACXN PRODUCT SPECIFICATIONS

R4H4. Product Specifications

Commercial High-Efficiency Condensing Units

Product Data TCC3018A through 4TCC3060A Single Package Convertible Cooling 13 SEER 1½ - 5 Ton R-410A. Mar. 03, 2006

NH4H4. Product Specifications 14 SEER HORIZONTAL DISCHARGE HEAT PUMP FOR USE WITH DUCTED INDOOR UNIT

15 SEER SINGLE- PACKAGED HEAT PUMP SYSTEM WITH PURON

High Heat COP. High/Low Stage

Vertical Upflow Horizontal Left Air Handlers

Product Data /4WCC3018A through 2/4WCC3060A Single Package Convertible Heat Pump 13 SEER 1½ - 5 Ton R-22/R-410A

PAJ3. Product Specifications

N4H4. Product Specifications

PACKAGE AIR CONDITIONER

TECHNICAL SPECIFICATIONS

4HP15L PRODUCT SPECIFICATIONS HIGH EFFICIENCY SPLIT HEAT PUMP SYSTEM UP TO 15 SEER & 9.0 HSPF COILS COMPONENTS COMPRESSOR WARRANTY CABINET DESIGN

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 FEATURES B-0703

FF1DNA, FF1DNE FAN COIL UNITS. Sizes 018, 024, 030. Form No. PDS FF1D.18.3 FEATURES FF1D

MACH N-407 Heat Pump Air-Cooled Chiller

MHCCW Chilled Water Ceiling Concealed With 5kW Electric Heat 2-Pipe Heat / Cool Fan Coil 30,000 BTUH

ACNF Series. Ceiling-Mounted Air Handlers 1½ to 2½ Tons

MHCCW Chilled Water Ceiling Concealed Without Electric Heat 2-Pipe Heat / Cool Fan Coil 18,000 BTUH

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS. HA300, HB360, HB480 & HB thru 50 NOMINAL TONS (50 Hz)

SPECIFICATIONS 4YCC3060A-SPEC-1A SINGLE PACKAGED GAS HEATING ELECTRIC COOLING 4YCC3060A1096/120B TAG:

TECHNICAL GUIDE LISTED. SPLIT-SYSTEM AIR CONDITIONERS 10 SEER R22 60Hz MODELS: AC036X10(3,4) THRU 060 (3 THRU 5 NOMINAL TONS, 3 PH) DESCRIPTION

N4A6. Product Specifications

Transcription:

Split System Heat Pump Product Data XL16i 4TWX6024, 036, 048 & 060E 2, 3, 4 & 5 Tons PUB. NO. 22-1754-17

Features and Benefits CLIMATUFF 2-stage scroll compressor Efficiency up to 18.0 SEER and 9.0 HSPF All Aluminum SPINE FIN coil WEATHERGUARD II top shields unit DURATUFF weather proof and rust proof base COMFT R mode approved for better comfort indoors QUICK-SESS cabinet, service access and refrigerant connections with full coil protection WEATHERGUARD fasteners Glossy corrosion resistant finish tarpaulin gray cabinet with anthracite gray top Internal compressor high/low pressure & temperature protection Liquid line filter/drier Low sound with advanced variable speed fan motor Service valve cover R-410A refrigerant From 70 to 100% capacity modulation 100% run test in the factory Low ambient cooling to 55 as shipped Extended warranties available 2011 Trane 2 22-1754-17

Contents Features and Benefits 2 General Data 4 Product Specifications 4 A-weighted Sound Power Level [db(a)] 4 Accessory Description and Usage 5 AHRI Standard Capacity Rating Conditions 5 Model Nomenclature 6 Electrical Data 7 Dimensions 10 Mechanical Specifications 11 22-1754-17 3

General Data Product Specifications Model No. 1 4TWX6024E1 4TWX6036E1 4TWX6048E1 4TWX6060E1 Electrical Data V/Ph/Hz 2 230/1/60 230/1/60 230/1/60 230/1/60 Min Cir Ampacity 14 22 28 39 Max Fuse Size (Amps) 20 35 45 60 Compressor CLIMATUFF - SCROLL CLIMATUFF - SCROLL CLIMATUFF - SCROLL CLIMATUFF - SCROLL RL AMPS - LR AMPS 10.3-52 16.7-82 21.2-104 28.8-152.9 Outdoor Fan FL Amps 0.74 0.74 1.00 2.80 Fan HP 1/8 1/8 1/5 1/3 Fan Dia (inches) 27.6 27.6 27.6 27.6 Coil Spine Fin Spine Fin Spine Fin Spine Fin Refrigerant R-410A 10/3-LB/OZ 10/8-LB/OZ 12/9-LB/OZ 13/3-LB/OZ Line Size - (in.) O.D. Gas 3 5/8 3/4 7/8 1-1/8 Line Size - (in.) O.D. Liquid 3 3/8 3/8 3/8 3/8 Dimensions H x W x D (Crated) 53.4 x 35.1 x 38.7 57.4 x 35.1 x 38.7 57.4 x 35.1 x 38.7 57.4 x 35.1 x 38.7 Weight - Shipping 305 307 360 361 Weight - Net 257 257 310 311 Start Components YES NO NO NO Sound Enclosure NO NO NO NO Compressor Sump Heat YES YES YES YES Optional Accessories: 4 Rubber Isolator Kit BAYISLT101 BAYISLT101 BAYISLT101 BAYISLT101 Snow Leg - Base & Cap 4" High BAYLEGS002 BAYLEGS002 BAYLEGS002 BAYLEGS002 Snow Leg - 4" Extension BAYLEGS003 BAYLEGS003 BAYLEGS003 BAYLEGS003 Hard Start Kit Scroll BAYKSKT260 BAYKSKT260 BAYKSKT260 Extreme Condition Mounting Kit BAYECMT004 BAYECMT004 BAYECMT004 BAYECMT004 Vertical Discharge Air Kit Base 4 BAYVDTA003 BAYVDTA004 BAYVDTA004 BAYVDTA004 Auto Charge Solenoid Kit BAYCAKT001 BAYCAKT001 BAYCAKT001 BAYCAKT001 Refrigerant Lineset 5 TAYREFLN9* TAYREFLN7* TAYREFLN3* TAYREFLN4* 1 Certified in accordance with the Air-Source Unitary Heat Pump Equipment certification program which is based on AHRI Standard 210/240. 2 Calculated in accordance with N.E.C. Only use HACR circuit breakers or fuses. 3 Standard line lengths - 60'. Standard lift - 25' Suction and Liquid line. For Greater lengths and lifts refer to refrigerant piping software Pub# 32-3312-0. ( denotes latest revision) 4 For accessory description and usage, see page 5. 5 * = 15, 20, 25, 30, 40 and 50 foot lineset available. MODEL SOUND POWER LEVEL [db(a)] A-weighted Sound Power Level [db(a)] A-WEIGHTED FULL OCTAVE SOUND POWER LEVEL db - [db(a)] 63 125 250 500 1000 2000 4000 8000 4TWX6024E 72 40.4 50.8 53.7 59.9 62.2 57.9 56.1 48.4 4TWX6036E 72 39.3 49.6 55.7 60.5 62.9 57.7 54.7 47.3 4TWX6048E 72 42 57.3 56.6 64 63.3 57.2 53.5 46.2 4TWX6060E 74 31.9 58.9 57.1 64.8 66.4 59.8 55.9 51.2 Note: Rated in accordance with AHRI Standard 270-2008. 4 22-1754-17

General Data Accessory Description and Usage Rubber Isolators 5 rubber donuts to isolate condensing unit from mounting frame or pad. Use on any application where sound transmission needs to be minimized. Extreme Conditions Mounting Kit Bracket kits to securely mount condensing unit to a frame or pad without removing any panels. Use in areas with high winds, or on commercial rooftops, etc. Low Ambient Cooling For low ambient cooling below 55 see Application Guide APP-APG013-EN. AHRI Standard Capacity Rating Conditions AHRI STANDARD 210/240 RATING CONDITIONS (A) Cooling 80 F DB, 67 F WB air entering indoor coil, 95 F DB air entering outdoor coil. (B) High Temperature Heating 47 F DB, 43 F WB air entering outdoor coil, 70 F DB air entering indoor coil. (C) Low Temperature Heating 17 F DB, 15 F WB air entering outdoor coil, 70 F DB air entering indoor coil. (D) Rated indoor airflow for heating is the same as for cooling. AHRI STANDARD 270 RATING CONDITIONS (Noise rating numbers are determined with the unit in cooling operation.) Standard Noise Rating number is at 95 F outdoor air. 22-1754-17 5

Model Nomenclature Outdoor Units 4 T W X 6 0 3 6 E 1 0 0 0 A A Gas Furnaces T U D 2 B 0 8 0 A C V 3 2 A A Refrigerant Type 4 = R-410A TRANE Product Type W = Split Heat Pump T = Split Cooling Product Family Z = Leadership Two Stage X = Leadership R = Replacement/Retail M or B = Basic A = Light Commercial Family SEER 3 = 13 6 = 16 0 = 20 4 = 14 8 = 18 5 = 15 9 = 19 Split System Connections 1-6 Tons 0 = Brazed Nominal Capacity in 000s of BTUs Major Design Modifications Power Supply 1 = 200-230/1/60 or 208-230/1/60 3 = 200-230/3/60 4 = 460/3/60 Secondary Function Minor Design Modifications Unit Parts Identifier Air Handlers Residential Refrigerant Type 4 = R-410A Application TE = Fully Convertible TG = Semi Convertible TF = Front Return Product Family E = Leadership Variable Speed P = Leadership C = Replacement/Retail B = Basic Flow Control 0 = No Flow Control 3 = Nonbleed TXV Feature Identifier 0 = Standard Unit F = Air-Tite Nominal Capacity in 1000 s (BTUH) Major Design Change Power Supply 1 = Single Phase Electrical Connection 0 = Pig Tails B = Circuit Breaker D = Pull Disconnect Future Option Factory Installed Heater Nominal KW Value Minor Design Modifications Unit Parts Identifier NOTE: There will be a phase-in of new model numbers for new air handlers over next 2 years. 4 T E E 3 F 3 6 A 1 0 0 0 A A Coils Residential Refrigerant Type 4 - R410A Product Family T-Premium (Heat Pump or Convertible Coil) Coil Design X - Direct Expansion Evaporator Coil Product Family C - Cased A Coil A - Uncased A Coil F - Cased Horizontal Flat Coil Coil Width (Cased/Uncased) A - 14.5" / 13.3" B - 17.5" / 16.3" C - 21.0" / 19.8" D - 24.5" / 23.3" H - 10.5" Refrigerant Line Coupling 0 - Brazed Model Number Distinguisher Major Design Change 4 T X C B 0 0 1 C C 3 H C A A Efficiency C - Standard S - Hi Efficiency (Derived from 10 SEER products) Refrigerant Control 3 - TXV - Non-Bleed Coil Circuitry H - Heat Pump Airflow Configuration A - Upflow Only U - Upflow / Downflow H - Horizontal Only C - Convertible - Upflow, Downflow, Left or Right Airflow Minor Design Change Unit Parts Identifier 6 22-1754-17

Electrical Data Schematic Diagrams (SEE LEGEND) 4TWX6024 Printed from D156993P02 22-1754-17 7

Electrical Data Schematic Diagrams (SEE LEGEND) 4TWX6036E Printed from D156631P06 Rev 00 8 22-1754-17

Electrical Data Schematic Diagrams (SEE LEGEND) 4TWX6048E 1 2 5 Printed from D156977 22-1754-17 9

Electrical Data Schematic Diagrams (SEE LEGEND) 4TWX6060E GR/YL RD BR/RD SC MS-1 T O POWER SUPPL Y PER UNIT NAMEPLAT E AND L OCAL CODES SUMP HTR TDL PR/WH PR/WH YL/ S S DFC R B B K 1 O O LED GR Y L K 3 K1 Y Y X2Y0 HPCO MS YL/RD RD YL/RD WH WH YL Y2C T 1 ACR K 2 T2 COMPR ESS SOLENOID YL NOTE 4&5 ODT-B ODT-A YL Y L Y L 1 TDR YL L PCO 3 OPT IONAL REMOTE OPTIONAL P-T RD Y L /R D START KITBAYKSK T263 O Y 1 RD 1 CS Y 2C B R RD 3 YL/RD X 2 CSR-1 CSR BR 1 2 5 CR Y2 YL Y L RD S R VARIAE SPEED AIR HANDLER Y lo Y / IOL C CPR Y 2 W3 W2 W1 T CBS ODS F G B R HEAT CONTROLS O / J TNS 24V YL/BR BR/RD GR/Y L MS-2 / 1 6 W2 W1 G R / TYPICAL HEAT/COOL THERMOSTAT O Y 1 B GR BR WH Y L ACR -A/C RECTIFIER CBS-COIL BOTTOMSENS CF -FAN CAPACIT CN -WIRE CONNECT CPR-COMPRESS CR -RUN CAPACIT CS -STARTINGCAPACIT CSR -CAPACIT SWITCHINGRELA Y DFC -DEFROST CONTROL EEV-ELECTRONIC EXPVALVE EEVC -ELECTRONIC EXP VALVECONTROL F -INDO FAN RELAY HPCO - HIGHPRESSURECUTOUT SWITCH IOL - INTERNAL OVERLOAD PROTECT LPCO -LOW PRESSURE CUTOUT SWITCH MS -COMPRESS MOT CONTA CT ODA - OUTDO ANTICIPAT OFT -OUTDO FAN THERMOSTAT ODS - OUTDO TEMPERATURESENS ODT -OUTDO THERMOSTAT P-TRD-PRESSURE TRANSDUCER SC -SWITCHOVERVALVE SOLENOID SM -SYSTEM ON-OFF SWITCH TDL -DISCHARGE LINE THERMOSTAT TDR-TIME DELAY RELA Y (5SEC DELAY ON) TNS - TRANSFMER TEMP -SENS, TEMPERATURE Y2C-HIGH CAPACITY CONTROL RELAY V ARIAE SPEED OD FAN MOT WARNING HAZARDOUS VOLTAGE! DISCONNECT ALL E LECTRICALPOWER INCLUDINGREMOTE DISCONNECTS BEFE SERVICING. Failure to disconnect power before servicing cancause severe personal injury ordeath. CAUTION USE COPPER CONDUCTS ONLY! UNIT TERMINALS ARE NOT DESIGNED TO ACCEPT OTHER TYPES OF CONDUCTS. Failure to do so may cause damage to the equipment. NOTES: 1. BE SURE POWE R SUPPLY AGRE ES WITH EQUIPMENTNAMEPLATE. 2. POWER WIRING ANDGROUNDING OF EQUIPME NT MUSTCOMPLY WITH L OCAL CODES. 3. LOW VOLTAGE WIRING T O BE NO.18 AWGMINIMUM CONDUCT. 4. ODT-BMUST BE SET LOWERTHAN ODT-A 5. IF ODT-BISNOT USED,CONNECT AJUMPER WIRE FROM W3 TO W2. IF ODT -A IS NOT USED, CONNECT AJUMPERWIRE FROM W2TOW1. 6. IF ELECTRIC HEATER DOE SNOT HAVE A3RD CONTACT (CH).CONNECT AJUMPER WIREFROM W3 TO W2. IF E L ECT RIC HEATER DOES NOTHAVE A2ND CONTACT(BH). CONNECT AJUMPER WIRE FROM W2 T OW1. 7. X2MUST BE CONNECTEDTOVARIAE SPEED AIR HANDLER T E RMINAL W3 AS SHOWN, F PROPE INDO AIRFLOWDURINGTHE DEFROSTCYCLE 8. BE SURE T HE JUMPERBETWEEN RAND IS CUTREMOVED. 9. WITH OAND Y/Y2ENERGIZED, INDO FANISAT80% AIRFLOW. 10. WITHO,Y/Y 2AND ENERGIZED, INDO FANISAT 100% AIRFLOW. RD YLRD YL/ B R Y 2 Y1 O E E V C T EMP E E V TO POWER SUPPL Y PER LOCAL CODE S FCANADIANINSTALLATIONS POUR INSTALLATIONS CANADIENNES CAUTION: NOT SUITAEF USE ON SY STEMSEXCEEDING150V -T O-GROUND ATTENTION:NE CONVIENT PAS AUX INSTALLATIONS DEPLUS DE150 VA L ATE R RE Printed from D156631P08 10 22-1754-17

Dimensions 4TWX6 Outline Drawing Note: All dimensions are in MM (Inches). MODELS BASE A B C D E F G H J K 4TWX6024E 4 1267 (49-7/8) 946 (37-1/4) 870 (34-1/4) 5/8 3/8 152 (6) 98 (3-7/8) 219 (8-5/8) 86 (3-3/8) 730 (28-3/4) 4TWX6036E 4 1369 (53-7/8) 946 (37-1/4) 870 (34-1/4) 3/4 3/8 152 (6) 98 (3-7/8) 219 (8-5/8) 86 (3-3/8) 730 (28-3/4) 4TWX6048E 4 1369 (53-7/8) 946 (37-1/4) 870 (34-1/4) 7/8 3/8 152 (6) 98 (3-7/8) 219 (8-5/8) 86 (3-3/8) 730 (28-3/4) 4TWX6060E 4 1369 (53-7/8) 946 (37-1/4) 870 (34-1/4) 1-1/8 3/8 152 (6) 98 (3-7/8) 219 (8-5/8) 86 (3-3/8) 730 (28-3/4) 22-1754-17 11 From Dwg. D152635 Rev. 16

Mechanical Specifications General The 4TWX6 is fully charged from the factory for matched indoor section and up to 15 feet of piping. This unit is designed to operate at outdoor ambient temperatures as high as 115 F. Cooling capacities are matched with a wide selection of air handlers and furnace coils that are AHRI certified. The unit shall be certified to UL 1995. Exterior is designed for outdoor application. Casing Unit casing is constructed of heavy gauge, G60 galvanized steel and painted with a weather-resistant powder paint on all louvers and panels. Corrosion and weatherproof CMBP-G30 DuraTuff base. Refrigerant Controls Refrigeration system controls include condenser fan, compressor contactor and high pressure switch. High and low pressure controls are inherent to the compressor. A factory installed liquid line drier is standard. Compressor The Climatuff 2-stage compressor features internal over temperature and pressure protection and hermetic motor. Other features include: roto lock suction and discharge refrigerant connections, centrifugal oil pump and modular plugs for electrical connections. Condenser Coil The outdoor coil provides low airflow resistance and efficient heat transfer. The coil is protected on all four sides by louvered panels. Low Ambient Cooling As manufactured, this unit has a cooling capability to 55 F. For low ambient cooling below 55 see Application Guide APP-APG013-EN. Trane www.trane.com Trane has a policy of continuous product and product data improvement and it reserves the right to change design and specifications without notice. 08/11