technical data FVXS-FV1B R-410A air conditioning systems Split Sky Air
Indoor Units R-410A FVXS-FV1B TABLE OF CONTENTS FVXS-FV1B 1 Features............................................................. 2 2 Specifications....................................................... 3 For indoor units only................................................. 3 Technical Specifications............................................. 3 Electrical Specifications............................................. 4 3 Dimensional drawing & centre of gravity........................ 5 Dimensional drawing................................................. 5 Centre of gravity..................................................... 6 4 Piping diagram...................................................... 7 5 Wiring diagram...................................................... 8 Wiring diagram....................................................... 8 6 Sound data.......................................................... 9 Sound pressure spectrum............................................ 9 Split Sky Air Indoor Units 1
t i y n k 1 r Ft o 0- i o 1 ld 4 np - FI Indoor Units R-410A FVXS-FV1B 1 Features BU S V A S X V RS Stylish design 1 Flat front panel: its stylish appearance blends easily within any interior décor and is more easy to clean. Titanium apatite photocatalytic air purification filter Can be installed against a wall or recessed Dual air discharge flow for better air distribution ECONO mode decreases power consumption so that other appliances that need large power supply can be used Home leave operation saves energy during absence Lightweight but sturdy design optional 5 steps standard Titanium apatite photocatalytic air purification filter 2 Split Sky Air Indoor Units
2 Specifications Indoor Units R-410A FVXS-FV1B 2-1 FOR INDOOR UNITS ONLY FVXS25FV1B FVXS35FV1B FVXS50FV1B Nominal input Cooling kw 0.015 0.015 0.027 (Indoor only) Heating kw 0.017 3 2-2 TECHNICAL SPECIFICATIONS FVXS25FV1B FVXS35FV1B FVXS50FV1B Casing Colour White Dimensions Packing Height mm 696 696 696 Width mm 786 786 786 Depth mm 286 286 286 Unit Height mm 600 600 600 Width mm 700 700 700 Depth mm 210 210 210 Weight Unit kg 14 14 14 Packed Unit kg 18 18 18 Heat Exchanger Dimensions Length mm 510 510 510 Nr of Rows 2 2 2 Fin Pitch mm 1.2 1.2 1.2 Nr of Stages 22 22 22 Tube type ø6.35 Hi-XU Fin Type Multi slit fin Fan Type Turbo fan Air Flow Rate Cooling High m³/min 8.2 8.5 10.7 Medium m³/min 6.5 6.7 9.2 Low m³/min 4.8 4.9 7.8 Silent Operation m³/min 4.1 4.5 6.6 Heating High m³/min 8.8 Medium m³/min 6.9 Low m³/min 5.0 Silent Operation m³/min 4.4 Fan Motor Model D48D-28 Number of steps 5 5 5 Motor Speed (cooling) High rpm 640 650 800 Medium rpm 520 530 700 Low rpm 400 410 600 Silent Operation rpm 360 380 520 Speed (heating) High rpm 680 Medium rpm 550 Low rpm 420 Silent Operation rpm 380 Fan Motor Output (high) W 48 48 48 Cooling Sound Power High dba 54 55 56 Sound Pressure High dba 38 39 44 Medium dba 32 33 40 Low dba 26 27 36 Silent Operation dba 23 24 32 Heating Sound Power High dba 54 Sound Pressure High dba 38 Medium dba 32 Low dba 26 Silent Operation dba 23 Refrigerant Type R-410A Piping connections Liquid (OD) Diameter (OD) mm 6.4 6.4 6.4 Gas Diameter (OD) mm 9.5 9.5 12.7 Drain Diameter (OD) mm 20 20 20 Heat Insulation Both liquid and gas pipes Air Filter Removable/washable/Mildew proof Air direction control Right, Left, Horizontal, Downward 2 Split Sky Air Indoor Units 3
2 Specifications Indoor Units R-410A FVXS-FV1B 2 2-2 TECHNICAL SPECIFICATIONS FVXS25FV1B FVXS35FV1B FVXS50FV1B Temperature control Standard Accessories Microcomputer control Installation manual Operation manual Wireless remote control Batteries Quantity 2 2 2 Remote control holder Drain hose Air supply filter Thermal insulation tape Quantity 2 2 2 2-3 ELECTRICAL SPECIFICATIONS FVXS25FV1B FVXS35FV1B FVXS50FV1B Power Supply Name V1 Phase 1 1 1 Frequency Hz 50 50 50 Voltage V 220-240 Current Nominal running Cooling A 0.13 0.13 0.17 current (RLA) Heating A 0.14 Maximum Running Current A 0.15 0.14 0.18 Wiring connections For Power Supply Quantity 3 3 3 Remark 4 for interunit wiring (including earth wiring) 4 Split Sky Air Indoor Units
Indoor Units R-410A FVXS-FV1B 3 Dimensional drawing & centre of gravity 3-1 Dimensional drawing FVXS25-35F 666 (half concealed) unit (mm) 3 Note) 1. The mark (Y) shows piping direction Operation lamp Timer lamp Room temp. thermistor Main unit fixing screw Front panel fixed screws (inside) Signal receiver Indoor unit ON/OFF switch Air outlet selection switch (Inside) Terminal block with earth terminal Liquid pipe (J6.4 CuT) Gas pipe (J9.5 CuT) Signal transmitter 3 Name plate Drain socket 584 (half concealed) Front panel fixed screws Hole for splint Hole for piping Main unit fixed screws Drain hose VP20 I.D. J20 O.D. J26 L220 Hole for splint Hole for piping Infrared remote control Air flow Required space For performance Hole for piping (Wall hole) Right/left (manual) Upper air outlet Adjusting the air flow direction Up/down (automatic) Cooling / dry Heat (Heat pump model) Upward air flow limit (OFF) 50 MIN 50 MIN (for maintenance) (for performance) (Wall hole) Lower air outlet Upward air flow limit (ON) Wall hole for half concealed 3D056135 FVXS50F 666 (half concealed) unit (mm) Note) 1. The mark (Y) shows piping direction Operation lamp Timer lamp Room temp. thermistor Main unit fixing screw Front panel fixed screws (inside) Signal receiver Indoor unit ON/OFF switch Air outlet selection switch (Inside) Terminal block with earth terminal Liquid pipe (J6.4 CuT) Gas pipe (J12.7 CuT) Signal transmitter Name plate Drain socket 584 (half concealed) Front panel fixed screws Hole for splint Hole for piping Main unit fixed screws Drain hose VP20 I.D. J20 O.D. J26 L220 Hole for splint Hole for piping Infrared remote control Air flow Adjusting the air flow direction Required space For performance Hole for piping (Wall hole) Right/left (manual) Upper air outlet Up/down (automatic) Cooling / dry Heat (Heat pump model) Upward air flow limit (OFF) 50 MIN 50 MIN (for maintenance) (for performance) (Wall hole) Lower air outlet Upward air flow limit (ON) Wall hole for half concealed 3D056136 Split Sky Air Indoor Units 5
Indoor Units R-410A FVXS-FV1B 3 Dimensional drawing & centre of gravity 3-2 Centre of gravity FVXS25-50F 3 4D056197 6 Split Sky Air Indoor Units
4 Piping diagram Indoor Units R-410A FVXS-FV1B FVXS25-35F Indoor unit 3 Muffler assy Heat exchanger 4 Thermistor on heat exchanger Field piping Turbo fan Fan motor Field piping Refrigerant flow Cooling Heating 4D056137 FVXS50F Indoor unit Muffler assy Heat exchanger Thermistor on heat exchanger Field piping Turbo fan Fan motor Field piping Refrigerant flow Cooling Heating 4D056138 Split Sky Air Indoor Units 7
5 Wiring diagram 5-1 Wiring diagram Indoor Units R-410A FVXS-FV1B FVXS25-50F 5 Rectifier Outdoor Infrared remote control Signal receiver Transmission circuit g Field wiring CAUTION Note that operation will restart automatically if the main power supply is turned off and then back on again. Indoor R F1U H1P,H2P M1F M1S M2S PCB1 PCB4 R1T,R2T S1 S49 S1W S2W(4) S4W X1M E3 E4 : Protective earth : Fuse : Pilot lamp : Fan motor : Swing motor : Lower air outlet motor : Printed circuit board : Thermistor : Connector : Operation switch : Upward air flow limit switch : Air outlet selection switch : Terminal strip : Earth terminal (heat. ex) : Earth terminal (shield plate) 3D055953 8 Split Sky Air Indoor Units
Indoor Units R-410A FVXS-FV1B 6 Sound data 6-1 Sound pressure spectrum FVXS25F (Cooling) FVXS25F (Heating) 3 Octave band sound pressure level db:(0db = 0.0002 μ bar) Octave band sound pressure level db:(0db = 0.0002 μ bar) 6 approximate threshold hearing for continuous noise approximate threshold hearing for continuous noise 3D056240 Octave band center frequency (Hz) NOTE 1 Operation noise differs with operation and ambient conditions. 2 Measure in anechoic room 3D056240 Octave band center frequency (Hz) NOTE 1 Operation noise differs with operation and ambient conditions. 2 Measure in anechoic room Legend Location of microphone Legend Location of microphone 50Hz 220-240V (H) 50Hz 220-240V (H) 50Hz 220-240V (L) 50Hz 220-240V (L) FVXS35F (Cooling) FVXS35F (Heating) Octave band sound pressure level db:(0db = 0.0002 μ bar) Octave band sound pressure level db:(0db = 0.0002 μ bar) approximate threshold hearing for continuous noise approximate threshold hearing for continuous noise 3D056239 Octave band center frequency (Hz) NOTE 1 Operation noise differs with operation and ambient conditions. 2 Measure in anechoic room 3D056239 Octave band center frequency (Hz) NOTE 1 Operation noise differs with operation and ambient conditions. 2 Measure in anechoic room Legend Location of microphone Legend Location of microphone 50Hz 220-240V (H) 50Hz 220-240V (H) 50Hz 220-240V (L) 50Hz 220-240V (L) Split Sky Air Indoor Units 9
Indoor Units R-410A FVXS-FV1B 6 Sound data 6-1 Sound pressure spectrum FVXS50F (Cooling) FVXS50F (Heating) 6 Octave band sound pressure level db:(0db = 0.0002 μ bar) Octave band sound pressure level db:(0db = 0.0002 μ bar) approximate threshold hearing for continuous noise approximate threshold hearing for continuous noise 3D056238 Octave band center frequency (Hz) NOTE 1 Operation noise differs with operation and ambient conditions. 2 Measure in anechoic room 3D056238 Octave band center frequency (Hz) NOTE 1 Operation noise differs with operation and ambient conditions. 2 Measure in anechoic room Legend Location of microphone Legend Location of microphone 50Hz 220-240V (H) 50Hz 220-240V (H) 50Hz 220-240V (L) 50Hz 220-240V (L) 10 Split Sky Air Indoor Units
Split - Sky Air The present publication is drawn up by way of information only and does not constitute an offer binding upon Daikin Europe N.V.. Daikin Europe N.V. has compiled the content of this publication to the best of its knowledge. No express or implied warranty is given for the completeness, accuracy, reliability or fitness for particular purpose of its content and the products and services presented therein. Specifications are subject to change without prior notice. Daikin Europe N.V. explicitly rejects any liability for any direct or indirect damage, In the broadest sense, arising from or related to the use and/or interpretation of this publication. All content is copyrighted by Daikin Europe N.V.. ISO14001 assures an effective environmental management system in order to help protect human health and the environment from the potential impact of our activities, products and services and to assist in maintaining and improving the quality of the environment. Daikin Europe N.V. is approved by LRQA for its Quality Management System in accordance with the ISO9001 standard. ISO9001 pertains to quality assurance regarding design, development, manufacturing as well as to services related to the product. Daikin units comply with the European regulations that guarantee the safety of the product. Daikin Europe N.V. is participating in the EUROVENT Certification Programme. Products are as listed in the EUROVENT Directory of Certified Products. Naamloze Vennootschap Zandvoordestraat 300 B-8400 Ostend, Belgium www.daikin.eu BTW: BE 0412 120 336 RPR Oostende EEDEN07-101 03/2007 Prepared in Belgium by Lannoo Copyright Daikin ÉEEDEN07-1011ËÍ