Extreme industrial environments Air/water heat exchangers (roof-mounted, wall-mounted) Recooling system

Similar documents
Fan-and-filter units 4.3. Features. Fast assembly. Application diversity and functions

Everyone talks about the future, but Rittal helps shape it and that includes. Modern cooling units with excellent efficiency and perfect interface

Rittal roof-mounted fans Efficiency on top

Product Management, Rev 3 December 2009

Cooling systems for electrical enclosures

Rittal roof-mounted fans

Thermal management for your cabinets!

LS Condensate Removal Pump INSTRUCTION MANUAL REVISION A

SIVACON sicube 8MF system cubicles 16/2 Introduction 16/3 8MF system cubicles 16/4 Preconfigured cubicles

Climate Control Quick Reference

Quality Products. Service Excellence.

electronics Protection

PRODUCT DATA COMPACT P - SERIES BY NILAN. Sanitary hot water production. Heating. Ventilation < 300 m 3 /h. Passive heat recovery.

SK 3363.xxx SK 3364.xxx SK 3373.xxx SK 3374.xxx SK 3375.xxx

Safe Enclosure Cooling

Combination Dryer HYBRITEC

A Evaporator B Fan C Terminal box D Hermetically sealed, output regulated digital scroll compressor E Condenser

Enclosure and process cooling

A cast iron case for our modular motors: High-voltage motors H-compact PLUS

condensate pumps For air conditioning and refrigeration technology eckerle.com

PRELIMINARY EDITION

AirUnit. Installation instructions. mfh systems modern floor heating. Decentralised domestic ventilation

Küba SG commercial

Power. Average noise level (DIN EN ISO 4871)

CDS 80. Continuous ventilation without dehumidification can be selected on the CDS 80 control panel.

revolutionary new way to cool your electrical enclosures

INSTALLATION AND OPERATING INSTRUCTIONS General operating instructions for sample gas conditioner Model: MAK 6

CASSETTE UNIT. Comfort Circle

How to Select and Size Enclosure Thermal Management Systems: White Paper, Title Page. How to Select and Size Enclosure Thermal Management Systems

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw

Rotary Screw Compressors. ASK Series With the world-renowned SIGMA PROFILE Flow rate 0.79 to 4.65 m³/min, Pressure 5.5 to 15 bar.

CIATCOOLER LJA. Chilled water production units USE. Attractive design, Compact and quiet

LS Condensate Removal Pump Installation, Operation and Service Instructions

Specifications Cooling tower series KAHV - hybrid recooler for closed circuit cooling with axial fans comprising:

ENCLOSURE COOLING. Glossary

Outdoor Enclosures. Outdoor Enclosures Protected like a bunker for all harsh environments

Cooling Towers. Energy-efficient solutions for open circuit, closed circuit and double-cell cooling towers.

Comfort Ceiling Fan Coil System INDULVENT ec. Draught-free ambient air distribution with cooling capacity up to 2600 W

Enclosure cooling unit

Thermal Management and Signaling Technology

Quality Enclosures. Service Excellence.

Rotary Blowers COMPACT Series With the world-renowned OMEGA PROFILE Air delivery 0.5 to 93 m 3 /min Pressure up to 1000 mbar, Vacuum to 500 mbar

Manual. Above-counter dispenser for hot drinks OTHG /12

TopVent Design Handbook

CZT CZT. High efficiency air to water heat pumps with E.V.I. compressors E.V.I. HP OTHER VERSIONS ACCESSORIES

Life insurance for your electronics

Content. Heating. Ventilating. Regulating and Monitoring. Lighting. Accessories

Thermal Management INDEX. Management. Thermal TM-1

CBU144. Compact Booster Unit - single pump To ensure the quality of potable water according to EN1717. Product specification sheet

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 21 to 39 kw

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw

Condensing Units CUS 15-60

stego_katalog_2008_en.qxp:englisch :09 Uhr Seite 1 Product Catalogue

Homepage > Products > Decentralised ventilation systems > Vertical units > Type FSL-V-ZAB/SEK FSL-V-ZAB/SEK

Product is subject to and complies with Regulation (UE) N.327/2011. cert. n Fan Coil Unit Cassette SkyStar Jumbo ECM. technical catalogue

Product Description. Options. Fan Voltage. Electrical Connections Technical Data - Key Characteristics

CDP 40 SWIMMING POOL DEHUMIDIFIER

KOOLTRONIC ENCLOSURE AIR CONDITIONER QUICK SHEET

cussons Refrigeration Assembly Range TECHNOLOGY REFRIGERATION AND AIR CONDITIONING CUSSONS TECHNOLOGY LABORATORY RECOMMENDATION

OPERA MORE. Use. Range. Drycoolers Air-cooled condensers. for LESS. Capacity: up to 1100 kw. Water misting. Free cooling

Rotary Screw Compressors. ASK Series With the world-renowned SIGMA PROFILE Flow rate 0.79 to 4.65 m³/min, Pressure 5.5 to 15 bar COMPRESSORS

"ESDDR" Series Electric Humidifier

CHG AIR COOLED WATER CHILLER WITH CONDENSATION BY HELICOIDAL AIR 8 to 17 kw

Technical System Catalogue Chillers for IT cooling

Rittal Liquid Cooling Package Inline

Static cooling ceiling system SKS-4/3 DS 4094 E /1. Technical Selection

SYSTEMS GENERAL CATALOGUE

GHP AWO 38 Technical overview

Refrigerated Air Dryer

Connection set. Radiator connection set for thermostatic and manual operation Ø 12

LZT High efficiency air to water heat pumps with E.V.I. compressors

Fan Coil Unit CULTRA

The new WAREMA external venetian blind 80 S PROVEN THINGS IN PERFECTION

Cooling unit Mechanical control

30RB Air-Cooled Liquid Chillers PRODUCT SELECTION DATA. Easy and fast installation. Compact, reliable and efficient

Quatro canal Super-powered climate control for 4-pipe systems

Gas Instantaneous Water Heater

SpaceKeeper Console (SKC)

Gas cooler series TC-Standard+

THERMAL MANAGEMENT. Outdoor 3.13 to

HYGROPHIL H process hygrometer

TopMaster Air Handling unit. Technical data

RVA /109. Heating Circuit ZONE Controller. Instructions for the INSTALLER

KAPTIV-MD KAPTIV-CS KAPTIV-CS-HP NUFORS-CR MAGY-UL MAGY COMPRESSED AIR CONDENSATE MANAGEMENT AND ENERGY SAVING PRODUCTS LEVEL SENSED DRAINS

Rotary Screw Compressors SM Series

AA-480-XX OUTDOOR THERMOELECTRIC COOLER ASSEMBLY USER S MANUAL

UV Flame Supervision System

THERMAL SOLUTIONS COAXIAL HEAT EXCHANGERS WKE, WKC

TF Series With SECOPAC LS

Heaters, Thermostats and Hygrostats

Energy-Saving Refrigeration Dryers SECOTEC

30RB Air-Cooled Liquid Chillers. Nominal cooling capacity 8-14 kw. Features. Quiet operation

Eldon Product Overview

HT V2 HT Split

WHITE PAPER: Thermal Management Solutions

Superior. A Compact Floor Standing Gas Fired, High Efficiency Condensing Hot Water Boiler. Outputs 120, 160, 200, 240, 280 kw

Gas cooler series RC 1.1

Scha tschra Hei u g E c sure heater R sista ces chauffa tes Scha e astverwar i ge. Risca dat re a tic de sa Resiste cia ca efact ra 3105 XXX

Dipl.-Ing. W. Bender GmbH & Co. KG Londorfer Str Grünberg Phone: Fax:

Excellent performance with low operating costs, Energy saving and environmentally friendly

Transcription:

3 Extreme industrial environments Air/water heat exchangers (roof-mounted, wall-mounted) Recooling system 3 04

eat exchangers One concept, two systems with very different operating methods Air/water heat exchangers cool the enclosure internal air via integration into an existing cooling water circuit or connection to a recooling system In this way, extremely high heat loads may be dissipated Air/air heat exchangers utilise the cooler ambient air to cool the air in the enclosure interior Based on the counterflow principle, the completely separate airflows are routed through the heat exchanger module via high-performance fans This prevents the ingress of dust from the environment into the enclosure interior eat exchangers Air/water heat exchangers Benefits, technical details 06 Wall mounting, useful cooling output 600/000 W 08 Wall mounting, useful cooling output 50/540 W 0 Wall mounting, useful cooling output 50/3000/0 W Roof mounting, useful cooling output 900//0 W 4 As a side panel for 600 mm deep TS 8 enclosures, useful cooling output 700 W 6 Air/air heat exchangers Benefits, technical details 8 Wall mounting, specific thermal output 75 60 W/K 0 Wall mounting, specific thermal output 90 W/K Wall mounting, specific thermal output 46 37 W/K 4 Wall mounting, specific thermal output 4 69 W/K 6 Roof mounting, specific thermal output 66 W/K 8 Practical example of an air/water heat exchanger In all areas with extreme ambient conditions, enclosure and climate control components are subject to special requirements This applies, for example, to metal foundries, engine factories and the chemicals and metal-working industries In such situations, low-maintenance air/ water heat exchangers are used as efficient all-rounders Either fed from existing cooling water networks or from separate recooling systems, these products contribute to an ideal climate inside the enclosure The cooling water absorbs the heat inside the heat exchanger and conveys it to the corresponding cooling system In this way, even small rooms are not subject to additional waste heat from the enclosure, and the electronics inside the enclosure are effectively protected Wood-processing industry Air/air heat exchanger (wall-mounted) Practical example of an air/air heat exchanger In the paper and wood-processing industries, for example, particular requirements are placed on climate control components They ensure good ventilation inside the enclosure, and heat dissipation out of the enclosure At the same time, they also prevent the ingress of super-fine dusts Air/air heat exchangers are ideal for this purpose, since they effectively dissipate the heat from the enclosure with their two hermetically separate air circuits based on the reverse current or counter-current principle, and prevent the ingress of ambient air into the enclosure The requirement for the use of air/air heat exchangers is that the ambient temperature must be below the enclosure internal temperature Standard control units such as thermostat, hygrostat and speed control for noise minimisation, as well as special C variants, extend the range of applications, eg to the railway sector 05

Air/water heat exchanger Benefits, technical details The air of the enclosure interior may also be cooled to below the level of the external temperature, if required, by using cooling water from a central recooling system The ingress of dust from outside into the cooled enclosure is prevented The waste heat from the enclosure does not raise the temperature of the ambient air, provided the heat exchanger and cold water supply system are spatially separated from one another Performance benefits of air/water heat exchangers Useful cooling output from 600 to 0 watts in three mounting variants: Wall mounting Roof mounting Integrated in the TS 8 side panel This installation form uses the space behind the side panel of the TS 8 Central cooling as cold water supplier By integrating the air/water heat exchangers into an existing cooling water circuit or connecting to a central recooling system, the necessary heat loss can be dissipated with exceptionally low energy costs Also suitable for use in extreme conditions Ideal at any installation site If direct dissipation of heat loss to the ambient air is not desired or ineffective due to the confined space, the air/water heat exchanger may offer an ideal solution Particularly by separating the exchanger from the recooling system, highly individual and effective cooling solutions for individual enclosures or bayed enclosure suites may be achieved Example: Parallel connection of air/water heat exchangers with cold water supply via a recooling system Overflow valves and bypass control should be integrated into the recooling system and the customer s own pipeline system respectively 3 Recooling system Air/water heat exchanger, roof-mounted 3 3 4 4 Air/water heat exchanger, wall-mounted Additional cooling water circuit for machine cooling Effective in extreme conditions Air/water heat exchangers may even be used in particularly extreme ambient temperatures from + to +70 C Even extreme levels of contamination in the ambient air, eg with dust and oil, do not affect functioning igh heat losses are dissipated in the most confined spaces, without emitting them directly to the ambient air A high operating ratio is achieved, thanks to the large surface area of the heat exchanger unit Also available in stainless steel Roof-mounted and wallmounted air/water heat exchangers are available with all water-carrying parts made from stainless steel 457 (V4A) for use in extreme conditions 06

Installation and service benefits Compact and lightweight Air/water heat exchangers have a low weight and a comparatively low volume in relation to the heat loss to be dissipated As a result, they are easily mounted on vertical enclosure surfaces or on the roof Air/water heat exchanger integrated into the side panel This side panel combines effective heat dissipation with minimum space requirements It may be used in all 600 mm deep, 800 mm/0 mm high TS 8 enclosures Virtually maintenance-free Because the ingress of ambient air into the heat exchanger is prevented, dirt is unable to penetrate Control of the air and water circuit is electronically monitored Air/water heat exchanger Control and safety included Roof-mounted heat exchanger control/monitoring The enclosure internal temperature is monitored by means of a thermostatically or electronically controlled magnetic valve It regulates the throughput of cooling water If the enclosure interior temperature rises above the set level, the floating change-over contact raises the alarm Leak monitoring of roof-mounted units In order to ensure that the enclosure interior is not at risk from cooling water, the sensor reports a leak in the event of water in the corrosion-resistant base tray igh protection category Thanks to the sealed design, a protection category of IP 55 to EN 60 59/09 is achieved Condensate management Any condensate arising is discharged via the / tube connector and a discharge hose, which should be laid with a gradient ensuring that there are no kinks In order to avoid increased condensation, the cooling water temperature should be adapted to match the required cooling output Any condensate occurring may be disposed of using an external electronic condensate evaporator Safety instructions When installing the device, the condensate discharge must be routed out of the enclosure! In order to avoid frost damage, the minimum permissible water temperature of + C must not be undercut at any point in the water cycle! It is vital that the manufacturers consent is obtained before adding anti-freeze! uring storage and transportation below freezing point, the water cycle should be drained completely using compressed air! Only set the thermostat as low as is strictly necessary, since undercutting the dew point with a falling water inlet temperature will result in condensation! It is very important that the enclosure is sealed on all sides (IP 54), particularly the cable entry (condensation)! Benefits: Useful cooling output from 600 to 0 watts Suitable for use even under extreme conditions and ambient temperatures of up to +70 C Also available with all water-carrying parts made from V4A System for TS 8 integrated into the side panel Important Air/water heat exchangers should always be used in conjunction with recooling systems or a cooling water cirucuit For calculation formulae and water quality requirements, please see page 88 or refer to the Internet at wwwrittalde 07

Technical specifications: All water-carrying parts made from copper External or internal mounting Small design for optimum space utilisation Floating contact in case of overtemperature Ideal for use in extreme ambient conditions Supply includes: Fully wired ready for connection, including drilling template, sealing mat and assembly parts SK 3400 Mounting holes for internal mounting 50 Ø 7 40 00 SK 3700 Mounting holes for internal mounting 98 40 Ø 7 98 475 50 35 50 80 75 8 50 06 = Condensate discharge / = Cooling water connection / = Condensate discharge / = Cooling water connection / Mounting cutout, external mounting Mounting cutout, external mounting 98 60 7 40 Ø 7 4 x 50 60 30 34 70 50 30 45 40 Ø 7 7 0 30 33 475 50 33 08 50 Model No SK 3400 3700 Rated operating voltage V, z 30, 50/60 imensions in mm Useful cooling output W L 35 W 0, l/h L 35 W 0, l/h 00 600 W 650 W 98 50 35 000 W 00 W Rated current max 07 A/08 A 06 A/055 A Pre-fuse T 0 A 40 A Cooling medium Water (see specifications on page 88) Water inlet temperature > + C to +30 C Permissible operating pressure p max to 0 bar Temperature range + C to +70 C Protection category to EN 60 59/09 IP 55* uty cycle 00% Type of connection Terminal strip Weight 7 kg 95 kg Colour RAL 703 Air throughput of fans 0 m 3 /h 40 m 3 /h Temperature control Thermostat-controlled magnetic valve Temperature monitoring Internal thermostat, with changeover contact, switching load 6 A, setting range +0 C to +60 C (factory setting +35 C) Special voltages available on request We reserve the right to make technical modifications * IP 65 available on request Accessories Packs of Page Temperature indicator 3400 74 oor-operated switch 47000 76 08

Air/water heat exchanger Wall mounting, useful cooling output 600/000 W Air/water heat exchanger Performance diagrams (IN 368) (50/60 z) Model No SK 3400 QK 3700 QK 00 000 900 800 700 600 300 00 750 50 000 45 C 35 C 45 C 35 C 5 C VW = l/h VW = l/h 5 0 5 0 5 30 35 Ti TW VW = l/h VW = l/h VW = 00 l/h Water resistance curves Model No SK 3400 P 3700 P 300 00 300 300 V Also required: Cooling water system such as Rittal recooling systems, see from page 76 onwards Approvals, see page 0 ENVIRONMENTALLY FRIENLY COOLING TECNOLOGY 750 5 C 00 50 5 Ti 0 5 0 5 30 TW Tw = Water inlet temperature ( C) QK = Continuous useful cooling output (W) Ti = Enclosure internal temperature ( C) 300 V V = Volumetric flow (l/h) P = Water resistance (mbar) Functional diagram Small design, ideal for the use with stand-alone enclosures in conjunction with Mini recooling systems 09

Technical specifications: All water-carrying parts made from copper External or internal mounting Slimline design for optimum space utilisation Floating contact in case of overtemperature Ideal for use in extreme ambient conditions Supply includes: Fully wired ready for connection with terminal strip or connection cable (3 m), including drilling template, sealing mat and assembly parts SK 3 Mounting holes for internal mounting 90 40 Ø 7 (4 x) SK 347000 Mounting holes for internal mounting 380 350 Ø 8 765 85 00 05 380 75 40 475 950 85 80 85 45 8 75 = Condensate discharge / = Cooling water connection / = Condensate discharge / = Cooling water connection / Mounting cutout, external mounting Mounting cutout, external mounting 50 4 380 300 64 950 9 90 70 5 Ø 7 (6 x) 96 6 85 750 75 35 5 40 30 Ø 8 85 470 33 Model No SK 3 347000 Rated operating voltage V, z 30, 50/60 imensions in mm Useful cooling output W L 35 W 0, l/h L 35 W 0, l/h 950 00 50 W 300 W 380 85 05 540 W 700 W Rated current max 038 A/04 A 043 A/05 A Pre-fuse T 40 A Cooling medium Water (see specifications on page 88) Water inlet temperature > + C to +30 C Permissible operating pressure p max to 0 bar Temperature range + C to +70 C Protection category to EN 60 59/09 IP 55* uty cycle 00% Type of connection Terminal strip Connection cable 3 m Weight 3 kg 7 kg Colour RAL 703 Air throughput of fans m 3 /h 40 m 3 /h Temperature control Thermostat-controlled magnetic valve Temperature monitoring Internal thermostat, with changeover contact, switching load 6 A, setting range +0 C to +60 C (factory setting +35 C) Special voltages available on request We reserve the right to make technical modifications * IP 65 available on request Accessories Packs of Page Temperature indicator 3400 74 oor-operated switch 47000 76 0

Air/water heat exchanger Wall mounting, useful cooling output 50/540 W Air/water heat exchanger Performance diagrams (IN 368) (50/60 z) Model No SK 3 0 800 600 QK 000 800 600 347000 50 0 750 QK 35 C 5 C VW = l/h VW = l/h 45 C 5 0 5 0 5 30 35 Ti TW VW = l/h VW = l/h VW = 00 l/h 45 C Water resistance curves Model No SK 3 P 300 00 347000 300 P 300 V Also required: Cooling water system such as Rittal recooling systems, see from page 76 onwards Approvals, see page 0 ENVIRONMENTALLY FRIENLY COOLING TECNOLOGY 50 000 5 C 35 C 00 750 5 0 5 0 5 30 Ti TW Tw = Water inlet temperature ( C) QK = Continuous useful cooling output (W) Ti = Enclosure internal temperature ( C) V 600 V = Volumetric flow (l/h) P = Water resistance (mbar) Functional diagram The slimline, compact design provides space-saving climate control, even in confined spaces and at high ambient temperatures

Technical specifications: SK 3804: All water-carrying parts made from stainless steel 457 (V4A) SK 3800 and SK 3600: All water-carrying parts made from copper External or internal mounting SK 3600: Suitable for external mounting only Compact design for optimum space utilisation Floating contact in case of overtemperature Ideal for use in extreme ambient conditions Supply includes: Fully wired ready for connection with terminal strip, including drilling template, sealing mat and assembly parts SK 38 SK 3600 50 950 450 80 Also required: Cooling water system such as Rittal recooling systems, see from page 76 onwards 00 = Condensate discharge / = Cooling water connection / = Condensate discharge / = Cooling water connection / Mounting cutout for external/internal mounting Only the 4 mounting holes, 7 mm diameter, are required for internal mounting 335 Mounting cutout, external mounting 450 40 350 5 340 440 455 80 950 904 Ø 7 463 80 60 75 Ø 8 4335 40 80 455 455 340 Model No SK 3804* 3800 3600 Rated operating voltage V,l z 30, 50/60 imensions in mm Useful cooling output W L 35 W 0, l/h L 35 W 0, l/h 950 50 W 650 W 450 50 3000 W 3 W 0 W Rated current max 04 A/048 A 0 A/ A Pre-fuse T 40 A Cooling medium Water (see specifications on page 88) Water inlet temperature > + C to +30 C Permissible operating pressure p max to 0 bar Temperature range + C to +70 C Protection category to EN 60 59/09 IP 55** uty cycle 00% Type of connection Terminal strip Weight 9 kg kg 56 kg Colour RAL 703 Air throughput of fans 40 m 3 /h 450 m 3 /h,000 m 3 /h Temperature control Thermostat-controlled magnetic valve Temperature monitoring Internal thermostat, with changeover contact, switching load 6 A, setting range +0 C to +60 C (factory setting +35 C) Special voltages available on request We reserve the right to make technical modifications * elivery times available on request ** IP 65 available on request Accessories Packs of Page Temperature indicator 3400 74 oor-operated switch 47000 76

Air/water heat exchanger Wall mounted, useful cooling output 50/3000/0 W Air/water heat exchanger Performance diagrams (IN 368) (50/60 z) Model No SK Water resistance curves Model No SK 3804 0 3 3000 QK 0 000 5 3800 0 0 45 C 5 C VW = l/h VW = l/h VW = 00 l/h 35 C 0 5 0 5 30 35 Ti TW 45 C VW = l/h VW = l/h VW = 00 l/h 3600 QK 9000 VW = l/h VW = l/h 8000 7000 6000 0 0 3000 0 000 5 0 5 0 5 30 35 45 C 35 C 5 C TW Ti 3804 / 3800 P 300 3600 300 300 V Approvals, see page 0 ENVIRONMENTALLY FRIENLY COOLING TECNOLOGY QK 3000 35 C P 0 5 C 00 000 Ti 5 0 5 0 5 30 TW Tw = Water inlet temperature ( C) QK = Continuous useful cooling output (W) Ti = Enclosure internal temperature ( C) 300 V V = Volumetric flow (l/h) P = Water resistance (mbar) Functional diagram 3

Technical specifications: SK 34904: All water-carrying parts made from stainless steel 457 (V4A) SK 34900 and SK 3900: All watercarrying parts made from copper Electronic leak monitoring ensures perfect safety of the entire system even with heavy condensation, and even in the event of a pipe fracture A wire screen serves as a water trap, providing additional mechanical protection against hosed water A fault signal contact is provided for temperature and leak monitoring The unit can be mounted on enclosures with a depth of mm and above Supply includes: Fully wired ready for connection with connector, including drilling template, sealing mat and assembly parts SK 349 SK 3900 80 404 547 = Condensate discharge / = Cooling water connection / 600 35 7 73 36 035 = Condensate discharge / = Cooling water connection / Also required: Mounting cutout Mounting cutout Cooling water system such as Rittal recooling systems, see from page 76 onwards 53 (538) Ø 8 (4 x) 695 (59) 356 Ø 8 (4 x) 397 80 64 3 0 6 39 80 Ø 4 00 3 58 3 95 30 87 3 3 = Air outlet 505 4365 5 3 = Air outlet 4 Model No SK 34904* 34900 3900 Rated operating voltage V, z 30, 50/60 imensions in mm Useful cooling output W L 35 W 0, l/h L 35 W 0, l/h 547 80 404 700 W 900 W 50 W W 600 3330 W/3 W 0 W/4300 W Rated current max 09 A/094 A A/8 A Pre-fuse T 40 A Cooling medium Water (see specifications on page 88) Water inlet temperature > + C to +30 C Permissible operating pressure p max to 0 bar Temperature range + C to +70 C Protection category to EN 60 59/09 IP 55** uty cycle 00% Type of connection Connector plug Weight 9 kg kg 4 kg Colour RAL 703 Air throughput of fans 390 m 3 /h 560 m 3 /h Temperature control Electronically controlled magnetic valve Temperature monitoring Collective fault signal via changeover contact, max switching load 50 V AC, 8 A, setting range +0 C to +60 C (factory setting +35 C) Special voltages available on request We reserve the right to make technical modifications * elivery times available on request ** IP 65 available on request Accessories Packs of Page Temperature indicator 3400 74 oor-operated switch 47000 76 4

Air/water heat exchanger Roof mounted, useful cooling output 900//0 W Air/water heat exchanger Performance diagrams (IN 368) (50/60 z) Model No SK Water resistance curves Model No SK 34904 750 50 0 QK 750 50 000 5 C 35 C VW = l/h VW = l/h VW = 00 l/h 45 C 3900 QK 9000 8000 7000 6000 0 0 3000 0 5 C 35 C VW = l/h VW = l/h 45 C 34904 / 34900 P 300 Approvals, see page 0 ENVIRONMENTALLY FRIENLY COOLING TECNOLOGY 750 5 34900 0 3 3000 0 5 0 5 30 35 TW VW = l/h VW = l/h VW = 00 l/h Ti 000 5 0 5 0 5 30 35 Ti TW 3900 600 00 300 V QK 0 35 C 45 C P 000 5 C 300 Ti 5 0 5 0 5 30 TW Tw = Water inlet temperature ( C) QK = Continuous useful cooling output (W) Ti = Enclosure internal temperature ( C) 600 V V = Volumetric flow (l/h) P = Water resistance (mbar) Functional diagram 5

Technical specifications: The units are designed as standard as a TS 8 side panel Suitable for installation as a rear panel for 600 mm wide TS 8 enclosure (maintain an appropriate distance from the mounting plate; the air inlet and outlet must not be obstructed) The system is designed for use in heavily contaminated ambient conditions Monitoring of the enclosure internal temperature via a thermostat with a double switch point Eliminates the time-consuming work of cutting out air inlet and outlet holes SK 33680 SK 336 797 546 50 346 496 57 56 390 3 90 94 40 0 997 546 50 346 496 57 56 390 90 94 0 3 40 Supply includes: Fully wired ready for connection with terminal strip, sealing material and assembly parts 495 45 495 45 = Water connections = ose 0 mm diameter 3 = Condensate discharge Model No SK 33680 336 Rated operating voltage V, z 30, 50/60 To fit TS 8 enclosures mm 600 800 Useful cooling output L 35 W 0, 00 l/h 700 W 600 0 Rated current max 045 A/05 A Pre-fuse T 40 A Cooling medium Water (see specifications on page 88) Water inlet temperature > + C to +35 C Permissible operating pressure p max to 0 bar Temperature range + C to +70 C Protection category to EN 60 59/09 IP 54 uty cycle 00% Type of connection Terminal strip Weight 6 kg Colour RAL 703 Air throughput of fans 70 m 3 /h Temperature control Thermostat-controlled magnetic valve Temperature monitoring Internal thermostat, with changeover contact, switching load 6 A, setting range +0 C to +60 C (factory setting +35 C) Special voltages available on request We reserve the right to make technical modifications Accessories Packs of Page Temperature indicator 3400 74 oor-operated switch 47000 76 6

Air/water heat exchanger As a side panel for 600 mm deep TS 8 enclosures, useful cooling output 700 W Air/water heat exchanger Performance diagram (IN 368) (50/60 z) Model No SK 33680 / 336 00 000 900 800 700 QK 600 300 5 C Ṿ = l/h V = 00 l/h 35 C 45 C Water resistance diagram Model No SK 33680 / 336 P 300 00 Also required: Cooling water system such as Rittal recooling systems, see from page 76 onwards Approvals, see page 0 ENVIRONMENTALLY FRIENLY COOLING TECNOLOGY 00 5 0 5 0 TW 5 30 35 Tw = Water inlet temperature ( C) QK = Continuous useful cooling output (W) Ti = Enclosure internal temperature ( C) Ti 300 V V = Volumetric flow (l/h) P = Water resistance (mbar) Functional diagram Optimum symbiosis between the TS 8 enclosure profile and climate control technology, plus effective space utilisation 7

Air/air heat exchangers Benefits, technical details The requirement for use of air/air heat exchangers is that the ambient temperature must be below the enclosure internal temperature ust and any aggressive ambient air is unable to enter the enclosure interior, thanks to the two separate air circuits Outstanding performance and design In all situations where the ambient air is sufficient for cooling, air/air heat exchangers offer effective, energy-saving solutions The high specific thermal output is attributable to the special construction and functional design of the heat exchangers: A large heat exchanger area with compact dimensions Exceptionally conductive materials and connections Fans that may be controlled separately Optimum flow conditions Variable output from 75 to 90 W/K Identical mounting cutouts for various specific thermal outputs facilitate easy adaptation of the output to various requirements Wall-mounted cooling units are likewise compatible with this interface This means that the same interface on the enclosure may be used for heat exchangers and cooling units of different output categories Flow and siting conditions Internal/external mounting Air/air heat exchangers may optionally be mounted on the outside of the enclosure or inside the enclosure The slimline design facilitates external mounting on the door, rear panel and side panels The range also includes a special heat exchanger for roof-mounting By diverting the waste air upwards, this prevents the creation of disruptive airflows in front of the enclosures The fans in the internal and external circuit may be activated separately and thus adapted ideally to the ambient conditions External mounting Internal mounting 8

Service / assembly benefits Simple maintenance The heat exchanger unit is very easily removed and cleaned The cleverly designed layout facilitates time-saving, costcutting maintenance Air/air heat exchangers Easily retrofitted Thanks to the low weight, simple assembly cutouts and problem-free attachment of the heat exchangers, a cabinet or enclosure may be easily retrofitted Reliability benefits igh protection category Thanks to the seamlessly sealed heat exchanger module, a protection category of IP 54 to EN 60 59/09 is achieved igh load capacity The motors of the fans are equipped with thermal winding protection Top quality: Guaranteeing protection for your electronics All devices in the Rittal TopTherm series are tested in accordance with the internationally valid approvals (GS, UL) Benefits: Specific thermal output from 75 to 90 W/K External and internal circuit may be controlled separately Mounting cutouts and enclosure dimensions identical to TopTherm wall-mounted cooling units Suitable for external and internal mounting Top design identical to TopTherm wall-mounted cooling units Important The temperature difference between the room temperature and enclosure internal temperature will have a decisive effect on the heat loss that may be dissipated For calculation basis see page 89 or refer to the Internet at wwwrittalde 9

Technical specifications: The compact sheet steel structure comprises an interchangeable heat exchanger module TopTherm heat exchangers may optionally be fitted to the inside (preferably on the door) or outside (side panel, door, rear panel or roof) of the enclosure Mounting cutouts are identical to the TopTherm cooling unit range The heat exchanger module is easily removed, for effortless cleaning All motors are equipped with thermal winding protection The heat exchanger membranes are conductively connected to one another and incorporated into the electrical safety features The internal and external air circuit may be connected separately The two separate air circuits effectively prevent the ingress of dust, humidity or dirt Supply includes: Fully wired unit ready for connection SK 3600 SK 3700* / SK 3800 / SK 3900 550 80 External mounting Internal mounting 08 50 4 950 External mounting 05*/5 Internal mounting 50 55*/75 Mounting cutout, external mounting Mounting cutout, internal mounting Mounting cutout, external mounting Mounting cutout, internal mounting 370 365 50 R6 (4x) 5 80 5 80 54 5 35 345 80 Ø 5 (x) 950 Ø 95 (8x) 55 950 90 380 90 550 50 54 66 49 58 550 5 x 45 Ø 8 (4x) 350 350 385 Ø 95 (4x) (30) 8 x 45 5 5 Model No SK 3600 3700 3800 3900 Rated operating voltage V, z 30, 50/60 imensions in mm W 80 550 50 Specific thermal output 75 W/K 30 W/K 45 W/K 60 W/K 950 05 950 5 Fans per heat exchanger Max rated current per fan 0 A/03 A 08 A/034 A 03 A/04 A 038 A/04 A Power per fan 3 W/7 W 60 W/75 W 70 W/90 W 85 W/90 W Air throughput of fans External circuit 65 m 3 /h / 35 m 3 /h 480 m 3 /h / 55 m 3 /h 600 m 3 /h / 65 m 3 /h 860 m 3 /h / 900 m 3 /h Internal circuit 65 m 3 /h / 35 m 3 /h 480 m 3 /h / 55 m 3 /h 600 m 3 /h / 65 m 3 /h 860 m 3 /h / 900 m 3 /h Temperature range 5 C to +55 C Weight kg 8 kg 9 kg kg Colour RAL 7035 Protection category to EN 60 59/09 Internal circuit IP 54 Special voltages available on request We reserve the right to make technical modifications Accessories Packs of Page Filter mats 3 386300 386 8 Metal filter 38630 38640 83 Thermostat 30000 75 Temperature indicator 3400 74 Speed control 300 76 0

TopTherm air/air heat exchanger Wall mounted, specific thermal output 75 60 W/K TopTherm air/air heat exchanger Approvals, see page 0 Functional diagram Top design for internal and external mounting

Technical specifications: The compact sheet steel structure comprises an interchangeable heat exchanger module TopTherm heat exchangers may optionally be fitted to the inside (preferably on the door) or outside (side panel, door, rear panel or roof) of the enclosure Mounting cutouts are identical to the TopTherm cooling unit range The heat exchanger module is easily removed, for effortless cleaning All motors are equipped with thermal winding protection The heat exchanger membranes are conductively connected to one another and incorporated into the electrical safety features The internal and external air circuit may be connected separately The two separate air circuits effectively prevent the ingress of dust, humidity or dirt Supply includes: Fully wired unit ready for connection SK 33000 580 External mounting 65 5 50 Mounting cutout, external mounting 35 80 Internal mounting Mounting cutout, internal mounting 370 34 5 95 350 380 Ø (x) Ø 3 (8x) 580 60 340 30 5 75 875 558 554 376 Ø 3 (4x) R6 (x) 34 535 580 Model No SK 33000 Rated operating voltage V, z 30, 50/60 imensions in mm Specific thermal output W 580 5 900 W/K Fans per heat exchanger Rated current 35 A/8 A Power per fan 05 W/45 W Air throughput of fans External circuit 850 m 3 /h / 945 m 3 /h Internal circuit 850 m 3 /h / 945 m 3 /h Temperature range 5 C to +55 C Weight 34 kg Colour RAL 7035 Protection category to EN 60 59/09 Internal circuit IP 54 Special voltages available on request We reserve the right to make technical modifications Accessories Packs of Page Filter mats 3 386 8 Metal filter 38640 83 Thermostat 30000 75 Temperature indicator 3400 74 Speed control 300 76

TopTherm air/air heat exchanger Wall mounted, specific thermal output 90 W/K TopTherm air/air heat exchanger Approvals, see page 0 Functional diagram Optimum space utilisation, thanks to the minimal equipment depth 3

Technical specifications: The compact aluminium structure comprises an interchangeable heat exchanger module Techline Mini heat exchangers may optionally be fitted to the inside (preferably on the door) or outside (side panel, door, rear panel or roof) of the enclosure The heat exchanger module is easily removed with 4 screws, for effortless cleaning All motors are equipped with thermal winding protection The heat exchanger membranes are conductively connected to one another and incorporated into the electrical safety features The internal and external circuits can be connected separately; separate routing effectively prevents the ingress of dust, moisture and dirt Supply includes: Fully wired unit ready for connection Fans are connected via two 3-wire connection cables, with wire end ferrules SK 30 / SK 36000 / SK 37000 Mounting cutout, internal mounting 76 E 76 Mounting cutout, external mounting 76 E 76 R 5 5 R 5 5 5 B C Ø 7 C B C Ø 7 30 30 F 07 R 5 5 R A 30 F 30 A SK 38000 / SK 39000 / SK 330000 Mounting cutout, internal mounting K E K Mounting cutout, external mounting K E K P P G N Ø 7 B C B Ø 7 C Ø 8 I I G R 5 5 R R 5 R 5 J F L M M F J L A A 5 Ø 8 C 35 G G A (mm) 3800 0 3800 0 7800 7300 B (mm) 875 875 75 70 70 3550 C(mm) 550 550 390 390 390 330 (mm) 70 70 0 50 3040 E (mm) 80 3480 80 300 4600 400 F (mm) 780 980 780 70 965 465 G(mm) 30 55 55 (mm) 060 600 600 I (mm) 65 400 400 J (mm) 65 300 300 K (mm) 350 600 600 L (mm) 300 60 60 M(mm) 655 35 35 N(mm) 480 360 360 P (mm) 350 85 85 R (mm) 075 075 075 75 75 75 Model No SK 30 36000 37000 38000 39000 330000 Rated operating voltage V, z 30, 50/60 imensions in mm W 875 380 65 875 65 Specific thermal output 46 W/K 87 W/K 8 W/K 95 W/K 300 W/K 370 W/K Fans per heat exchanger Max rated current per fan 08 A/05 A 036 A/045 A Power per fan 43/4 W 8/03 W Air throughput of fans External circuit 60/300 m 3 /h 570 m 3 /h Internal circuit 60/300 m 3 /h 570 m 3 /h Noise level 54 db (A) 57 db (A) 6 db (A) 675 db (A) 64 db (A) Temperature range 5 C to +55 C Weight 43 kg 49 kg 50 kg 5 kg 74 kg 8 kg Colour Black anodised Cooling surface 06 m 099 m 09 m 063 m 0 m 3 m Protection category to EN 60 59/09 Internal circuit IP 54 Connection cable x 3 m x 5 m Special voltages available on request We reserve the right to make technical modifications Accessories Packs of Page Thermostat 30000 75 Temperature indicator 3400 74 Speed control 300 76 75 380 65 7 0 7 780 0 355 730 0 4

Techline Mini air/air heat exchangers Wall mounted, specific thermal output 46 37 W/K Techline Mini air/air heat exchangers IR registered design no M/03 569 with validity for BE, C, E, ES, FR, IT, LI, LU, NL ENVIRONMENTALLY FRIENLY COOLING TECNOLOGY Approvals, see page Functional diagram Extremely compact, therefore suitable for flexible use Techline Mini heat exchangers for targeted heat dissipation in particularly confined spaces 5

Technical specifications: The compact aluminium structure comprises an interchangeable heat exchanger module Techline heat exchangers may optionally be fitted to the inside (preferably on the door) or outside (side panel, door, rear panel or roof) of the enclosure The heat exchanger module is easily removed with 4 screws, for effortless cleaning All motors are equipped with thermal winding protection The heat exchanger membranes are conductively connected to one another and incorporated into the electrical safety features The internal and external circuits can be connected separately; separate routing effectively prevents the ingress of dust, moisture and dirt Supply includes: Fully wired unit ready for connection Fans are connected via two 3-wire connection cables, with wire end ferrules SK 33000 / SK 330 / SK 333000 / SK 334000 Mounting cutout, internal mounting K E K G Mounting cutout, external mounting 36 Ø 7 B C B I I G 75 5 5 75 J L M F A SK 330 / SK 336000 Mounting cutout, internal mounting 60 E 60 5 5 75 75 Mounting cutout, external mounting 36 Ø 7 Ø 4 B B C 58 58 0 0 6 44 35 F 0 A K E K 85 85 Ø 7 C Ø 8 75 5 75 5 M J F L A 60 E 60 85 85 Ø 4 C Ø 7 Ø 8 75 75 5 5 6 44 35 F 0 A G G A (mm) 0 4800 4800 7800 6000 7800 B (mm) 70 70 4390 4390 3550 4390 C(mm) 390 390 4070 4070 330 4070 (mm) 3880 3880 3040 3880 E (mm) 8800 600 600 4600 800 4600 F (mm) 765 9965 9965 965 965 3765 G(mm) 55 55 55 55 (mm) 600 600 600 600 I (mm) 400 400 400 400 J (mm) 300 300 300 300 K (mm) 600 600 600 600 L (mm) 60 60 60 60 M(mm) 35 35 35 35 Model No SK 33000 330 333000 334000 330 336000 Rated operating voltage V, z 30, 50/60 imensions in mm W 7 0 7 480 0 Specific thermal output 40 W/K 440 W/K 630 W/K 690 W/K 445 W/K 48 W/K 439 480 0 439 780 0 355 600 575 439 780 575 Fans per heat exchanger Max rated current per fan 036 A/045 A 05 A/09 A Power per fan 8/03 W 55/65 W Air throughput of fans External circuit 570 m 3 /h 45/460 m 3 /h Internal circuit 570 m 3 /h 45/460 m 3 /h Noise level 6 db (A) 65 db (A) 68 db (A) 6 db (A) 645 db (A) 63 db (A) Temperature range 5 C to +55 C Weight 93 kg 03 kg 5 kg 89 kg 8 kg 48 kg Colour Black anodised Cooling surface 46 m 343 m 544 m 700 m 8 m 403 m Protection category to EN 60 59/09 Internal circuit IP 54 Connection cable x 5 m Special voltages available on request We reserve the right to make technical modifications Accessories Packs of Page Thermostat 30000 75 Temperature indicator 3400 74 Speed control 300 76 6

Techline air/air heat exchangers Wall mounted, specific thermal output 4 69 W/K Techline air/air heat exchangers ENVIRONMENTALLY FRIENLY COOLING TECNOLOGY Approvals, see page Functional diagram Effortless cleaning by simply removing the heat exchanger module Simple cutouts permit retrofitting into pre-installed enclosures 7

Technical specifications: The heat exchanger module and the enclosure of the heat exchanger form a single unit, thereby substantially enlarging the surface area for heat dissipation This design gives the unit an extremely low weight (68 kg) combined with a high degree of enclosure rigidity The built-in radial fans ensure effective air circulation, even where the enclosure is densely packed All motors are equipped with thermal winding protection As you would expect, the heat exchanger membranes are conductively connected to one another and thereby incorporated into the electrical safety features The internal and external circuits can be connected separately; separate routing effectively prevents the ingress of dust, moisture and dirt Supply includes: Fully wired unit ready for connection Fans are connected via two 3-wire connection cables, with wire end ferrules SK 348000 440 36 360 = Air inlet = Air outlet Ø7(4x) 595 600 480 40 Ø 3 (x) 30 6 30 45 50 440 Model No SK 348000 Rated operating voltage V, z 30, 50/60 imensions in mm Specific thermal output W 595 36 440 66 W/K Fans per heat exchanger Max rated current per fan 035 A Power per fan 75 W Air throughput of fans External circuit 965 m 3 /h Internal circuit 965 m 3 /h Noise level 65 db (A) Temperature range 0 C to +55 C Weight 68 kg Colour Black anodised Cooling surface 440 m Protection category (internal circuit) to EN 60 59/09 IP 54 Connection cable approx 30 m Special voltages available on request We reserve the right to make technical modifications Accessories Packs of Page Thermostat 30000 75 Temperature indicator 3400 74 Speed control 300 76 8

Techline air/air heat exchangers Roof mounted, specific thermal output 66 W/K Techline air/air heat exchangers IR registered design no M/03 569 with validity for BE, C, E, ES, FR, IT, LI, LU, NL ENVIRONMENTALLY FRIENLY COOLING TECNOLOGY Approvals, see page Functional diagram Roof-mounted heat exchangers are also easily retro-fitted 9