CRISTAL Built-in Dish Sterilizer Instruction Manual Model No.: D36DSS Version Number: 01 Revision Date: September 2014
Dear user: Thank you for your purchase of CRISTAL built-in dish sterilizer! Please read the instruction manual carefully before operating the dish sterilizer. If you have any enquiries, please do not hesitate to contact the service provider or the manufacturer, we will provide you the service you need with passion. The manufacturer declines all responsibility for damage to persons or property resulting from failure to observe the following precautions. Thank you for your cooperation. Please properly retain the instruction manual for future reference. Remarks: Specifications and design subject to change without notice. If there were any enquiries, please visit our website. For more details, please visit the website below: www.cristal.com.hk
Content 1. Structural Diagram... 1 2. Specifications... 2 3. Installation... 3 4. Operation... 5 5. Daily Maintenance... 9 6. Replacement... 10 7. Troubleshooting... 11 8. Electrical wiring diagram... 12 9. Packing List... 12 10. After- sale service... 14
1. Structural Diagram Figure 1 Figure 2 1. Display interface 7. Handle 13. Side handle 2. Control panel 8. Glass door 14. Air vent 3. Power cord 9. U-Shape decorative 15. Air vent plate 4. Inner cabinet 10. Retractable slider rail 5. Door seal 11. Lower shelf 6. Door switch Outer 12. Upper shelf glass door/ drawer panel Note: Please take out the tape between the door and the door seal. Control Panel Induction Button Function indicator Sensor switch button (Figure 3) Timer indicator Note: The indicator on the panel will only light up when specific function and timer has been set. This image shows the position of each indicator. 1
2. Specifications Model No. D36DSS Rated Voltage 220V ~ Rated frequency Rated power 50Hz 300W Operating Mode Function / Display Sterilizing Drying Freshness and cleanliness Induction touch control 120/90/60 min. 30 min. 120/90/60 min. Cleaning method Cleaning duration Ozone + UV combination cleaning method 60 min. Ozone density 20mg / m³ Drying temperature Service life of ozone and UV tube Rated capacity Rated duty 70 >1,000 hr 75L / 90 L Upper layer: 5 kg; lower layer: 7.5kg Applicable standard GB17988 2004 / GB4706. 1-1998 2
3. Installation Note: This product can only be installed where emendation is available. This unit is a compulsory grounding protection product. Disconnect power before cleaning; do not place flammable objects or solution inside the device. Precautions When embedding the dish sterilizer in a kitchen cabinet, it is possible to mount it in the lower part of the kitchen cabinet or the upper part of a vertical cabinet as required. However, it is necessary to set a vent hole (see Fig. 7 and Fig.9) in the joint to keep it well ventilated. For the setup of the sterilizer, easy operation and maintenance shall be considered and the unit shall be kept even and stable on a solid surface (without inclination) with the door / drawer panel upright and at least 15cm from any stove and open fire. The distance between the dish sterilizer and power socket shall fall within 1.5 meter. The socket shall be securely grounded and connected to conforming power supply. Do not expose the dish sterilizer and power socket to moisture. For handling, lift the unit gently by placing your hands on its left and right side handles or bottom. Do not lift it by holding its door / drawer panel handle. How to install the dish sterilizer Reserve a square compartment in proper dimensions in the given position on the kitchen cabinet as shown in Fig. 7 ~ Fig 9 (the base surface of the square hole shall be horizontal and secure). 3
Evenly place the unit into the square compartment. (Figure 6). Open the door and you will see two empty screw hole. (See Fig. 7). Fix the unit body into place by inserting the two supplied screws in the screw holes (see Fig. 8). The sterilizer shall be kept even rather than oblique. Once it is installed, commission the machine as required in the instruction manual and make sure it operates normally before service. Installation dimension 4
4. Operation Precautions Make sure the mounting screws of the dish sterilizer are securely and correctly tightened before operating the unit. Thoroughly clean the water in articles before storing them to ensure that they can effectively and fully cleansed and dried. For storing tableware, at first wipe off the accumulated water in them and place them one by one on the bearers on side. Avoid tableware from overlapping as the cleansing and drying performance will deteriorate if they are kept too close. The freshness and cleansing preservation shall be performed individually when the unit cooled down (at room temperate). Temperature preservation shall also be performed separately in order to prevent contamination. To store vegetables and fruits, first clean and dry the, and then put them on the bearer in order (never use any plastic bag). Keep some clearance between them as in this way ozone may fully contact the surfaces of vegetables and fruits for the purpose of freshness and cleanliness preservation. When storing tableware or food, start the machine every other day so as to prevent bacteria growth. During operation, keep the door / drawer closed tight in order to prevent ozone leakage or UV of radiation. At this time, you may smell slight odor of ozone. This is normal as a small amount of ozone will soon be reduced into oxygen, purifying the air. 5
Do not open the cabinet door during operation. Do not open the door until 20 min. after it stops so as to prevent ozone leakage or burn. In case of damage of the power cord, it must be replaced with dedicated flexible power cord or spare parts supplied by the manufacturer or its service department. In ozone leakage or lighting from UV tube is found directly without any euphotic object (e.g. glass), stop the unit immediately and contact qualified service personnel for repair. Do not directly look at the operating ozone and UV tube without any protection. The ozone and UV tube is made of glass and has weak shock resistance. Hence prevent it from impact and breakage during operation or cleaning. In case of malfunction of the ozone and UV tube or ozone generator, it shall be replaced with the spare parts of the same specifications so as to ensure its performance and operative safety. Any unauthorized person is not allowed to disassemble or repair the machine or replace any part. Keep children away from the dish sterilizer. Operating guide A. Securely plug in the power cord B. Close the cabinet tight and proceed as follow: Warning: Make sure that the cabinet is closed tight before any further operation. Otherwise it is subject to ozone leakage or UV radiation. C. Determination of function and operating duration. 6
Operating guide Operations of the buttons In stop status, press the ON / OFF button. Then the ON / OFF indicator light illuminates and the machine is ready to operate. The functions of the Sterilizing button 1. When the Sterilizing button is pressed once (the LED light of 120 turned on), the Sterilizing button light up, the icon Sterilizing appears on the display and the timer indicates 120. Then the unit starts the 120- min timing disinfection, including 50 min. of ozone and UV radiation operation, 10 min. of interruption and 60 min. of drying. Then it automatically stops 2. Press the Sterilizing button twice continuously. The Sterilizing button lights up (the LED light of 90 lights up), the icon Sterilizing appears on the display and the timer turns to indicate 90 to 120. The duration includes 35 min. of ozone and UV radiation operation, 10 min. of interruption and 45 min. of drying. Then it automatically stops. 3. Press the Sterilizing button for three times continuously. The Sterilizing button lights up (the LED light 60 lights up), the icon Sterilizing appears on the display and the timer turns to indicate 60 from 90. The duration includes 20 min. of ozone and UV radiation operation, 10 min. of interruption and 30 min. of drying. Then it automatically stops. 7
The functions of the Drying button When the Drying button is pressed (the LED light 30 lights up), the icon Drying appears on the digital display and the timer turns to indicate 30 from 60. Then the unit start drying operation during which only hot air is output. It automatically stops after 30 min. of count down. The function of the Cleansing button 1. When the Cleansing button is pressed once (the LED light 120 lights up), the icon Cleansing appears on the digital display and the timer indicates 120 before 120 min. of timing Cleansing operation, which comprises 100 min. of ozone and UV radiation operation, 10 min. of interruption and 10 min. of cold air blowing. Then it automatically stops. 2. Press the Cleansing button twice continuously. The Cleansing button lights up (the LED light 90 lights up), the icon Cleansing appears on the display and the timer turns to indicate 90 from 120. The duration includes 70 min. of ozone and UV radiation operation, 10 min. of interruption and 10 min of cold air blowing. Then it automatically stops. 3. Press the Cleansing button three times continuously. The Cleansing button lights up (the LED light 60 lights up). The icon Cleansing lights up and dynamically appears on the VFD display. The timer turns to indicate 60 from 90. The operation includes 40 min. of ozone and UV radiation operation, 10 min of interruption and 10 min of cold air blowing. Then it automatically stops. 8
Cautions 1. For Functional setting, the interval between two continuous operations shall not exceed 3 seconds; otherwise the default settings of the function will be enabled 2.. Once a pressing (touching) time is set, it cannot be changed unless you restart the unit and set it again. 3. After the setting of a pressing (touching) time, the machine will delay for 3 seconds after operation. 4. In the standby mode, the machine will automatically stop if no operation is performed within 2 seconds. 5. Daily Maintenance Daily maintenance of the dish sterilizer shall be performed after the inside of the cabinet is fully cooled down so as to prevent burn. Keep the inside and outside of the cabinet clean by cleaning away the stains on the door, inner cabinet and bearers with a soft cloth dampened in neutral detergent solution and then wiping it dry with a dry cloth. Never use corrosive or abrasive detergent as this may discolor its surface. Do not wipe or impact the unit by applying an excessive force, otherwise it is subject to damage or deformation. To clean the inner cabinet, first remove the bearers and cabinet door and then clean them individually. After cleaning, wipe them dry with a dry cloth and replace them. Regularly check the lubrication of the hinges on the cabinet door. If they are not fully lubricated or the cabinet door sounds squeak when opening, lubricate them timely. 9
6. Replacement In case of malfunction of the ozone and UV tube, please replace following the instructions. (Please make sure the UV tube for replacement is annexed to the dish sterilizer requirement): 1. Remove the upper cabinet and door. (Figure 9). 2. Hold onto the tube sheath (Figure 10) with both hands, apply light force to remove. 3. Twist the tube clockwise or anti-clockwise for 90 for removal (Figure 11). 4. Place the two sides of the tube where it aligns with the holder, then twist it clockwise or anti-clockwise 90 to install. 5. Buckle one side of the tube into the dish sterilizer positioning hole, then follow hold the tube (Step 2), and place the other side to the positioning hole. 6. Fix the door to the unit, install the upper cabinet in place. Model No. of the UV tube: ZW20S19 Y Standard: AC220V/50Hz/20W Mainline spectrum: 253.7nm Important! Do not flush the unit. The ozone generator or ozone and UV tube shall never be exposed to water or moisture. Warning: Make sure to unplug the power cord before accessing any terminal! 10
7. Troubleshooting Problem Possible Cause Solution The LCD light failed to light Power failure Check the power supply. up. The power cord is not properly Correctly connect the plug connected. Disoperation of the functional Correctly set it again buttons. Excessive ozone leakages The deformation or degradation Call service to repair. of the door seal. Poor drying effect Food is placed improperly. Place it appropriately. The water accumulated in tableware is not thoroughly cleared. Thoroughly remove the water accumulation before storage. When testing the machine, ozone is smelt but the ozone The ozone generator or the ozone and UV tube failure. Contact our service department for repair. and UV tube does not light up. Warning: In consideration of your safety, do not attempt to disassemble and repair a faulty dish sterilizer without authorization. If the above troubles persist after treating as indicated or no fault is determined, unplug the power cord (cut off the power supply) and contact our service department for repair. 11
8. Electrical wiring diagram 9. Packing List Serial No. Name Quantity 1 Main unit 1 2 Instruction Manual 1 3 Mounting screws 2 4 Warranty Card 1 12
Safety Tips All the packaging materials are recyclable, please handle them properly. Do not allow children to play with the plastic wraps and the package box, it could cause suffocation. Touching some of the internal component can cause electric shock. Do not disassemble the machine. Please use the power cord with a ground terminal blocks. If the power cord is damaged, it must be replaced by the manufacturer, its service agent or similarly qualified persons in order to avoid a hazard. To avoid the risk of fire, do not expose the dish sterilizer to heat or flames. Disconnect the unit from power source when cleaning the machine. Please wear gloves and do not use corrosive cleaning solution; do not flush the unit with water. Clean the cavity and the surface of the unit regularly. Please follow the instructions carefully when operating the device! 13
10. After- sale service In case of malfunction of your dish sterilizer, you may solve the problem by following Troubleshooting. If it persists, please contact your dealer or nearest authorized service department by telephone or e-mail indicating the following information: Sole Agent: Great Treasure Group Tel: (852) 37526111 info@gtgroup.com.hk 1. Your name, telephone number and communication address; 2. The model number and serial number of your machine; 3. Descriptions for the symptoms of the trouble. We will furnish you with warmhearted, considerate and satisfying services. Here again, thank you for your purchase of our products. The above contents are subject to change without future notice. 14