PCH/new Series. High performance, total flexibility

Similar documents
PCH Heating Condensing Module for Air Handling and Roof Top Units

OnePlus. Packaged Air Handling Units for Ducted Installations. Caring for the environment!

Rapid. Suspended Warm Air Heater. Caring for the environment!

Heat Exchanger Module for Industrial Applications

AquaKond Split. Caring for the environment! New Condensation Boilers. Efficiency up to 109% 4 Stars. AquaKond 70 kw Standard I.S.P.E.S.L.

WALL HUNG GAS BOILER FOR C.H. AND PREDISPOSTION FOR INSTANTANEOUS D.H.W. PRODUCTION (with optional kit) MODELS 34,8 kw (depotenziata) 50 C

RIELLO 40 GS/M SERIES

PK-N Floor Standing Heater

CAST IRON PREMIX HIGH EFFICIENCY GAS FIRED BOILER kw BRILEY DESIGN MANUAL

Technology marries design. The boiler finally becomes a piece of design, emerging as a protagonist in a new domestic environment.

white blue cobalt bordeaux light oak (rovere)

Operating, Installation and Maintenance Manual PRH Warm Air Heater Module 2 stages

RL/1 SERIES. One Stage Light Oil Burners FIRING RATES LIGHT OIL RL 34/1 MZ kw

VICTRIX 50 1 SPECIFICATIONS. Wall mounted condensing boilers

VICTRIX 90 VICTRIX 115 Wall-hung condensing boilers for high power

VERY LOW TEMPERATURE CONDENSING UNIT Low NOx Class 5 MODELS SEASONAL EFFICIENCY A A A A A A A

1 VICTRIX ZEUS Superior kw I features

AGUAdens TM 100% residential condensing D.H.W. wall-mounted water heaters ( litres) AISI 316 D.H.W. WORKING PRESSURE TITANIUM CONDENSING

Technology marries design. The boiler finally becomes a piece of design, emerging as a protagonist in a new domestic environment.

Superior. A Compact Floor Standing Gas Fired, High Efficiency Condensing Hot Water Boiler. Outputs 120, 160, 200, 240, 280 kw

The mechatronics of EVE 05

Fonte Lx NEW. Instantaneus Gas Water Heaters, conventional flue, low NOx. Residential Heating. compliant. Fonte Lx 14. Fonte Lx 11

24-28 kw Conventional Combi Gas Boiler. Lawa / LawaPlus

ENERGY TOP. Condensing boiler solutions

Room sealed circuit appliance sold without the terminal or the combustion air supply and exhausted gas ducts. TYPE C 63 TYPE B TYPE B 23

EOLO MODULATING AND CONDENSING SUSPENDED GAS AIR HEATER HEATING COOLING GREEN ENERGY AIR HEATING TECHNOLOGY AND INNOVATION

INSTALLATION AND OPERATION MANUAL

C Tahiti. condensing

Air curtains. 114 MRX condensing gas air curtain. 118 MRA-H gas air curtain. 121 MRA-A ventilation only air curtain

Ciao Green Condensing Wall-Hung Boilers

STOKVIS R40 EVOLUTION RANGE. High Efficiency Fully Condensing Ultra Low NOx Wall Mounted Gas Fired Boilers

24/31-28/35-33/40 kw Premix System Condensing - ErP Combi Gas Boilers. Enerwa / EnerwaPlus.

MYdens T 5WARRANTY 1:20. Ti TITANIUM. commercial gas condensing boilers. boilers from 60 to 280 kw AISI 316 YEARS WORKING PRESSURE HEAT EXCHANGER

CITY OPEN - CITY BOX from 25 to 35 kw

CITY PLUS. Wall-hung condensing boilers. ErP 24 HE 30 HE. Ready

ACCUMULATION OF EUROPEAN CLASS

Floor standing boilers. RMG Mk.II RS Mk.II

Quinta Pro Range. The New Remeha. Condensing Boilers REMEHA QUINTA PRO RANGE. High efficiency wall hung condensing boiler with ultra low NOx emission

Typical Specifications For: ADVANTUS TM DOMESTIC HOT WATER SUPPLY Models AV(W)0500 AV(W)4000

User, Installation, and Maintenance Manual

VICTRIX Superior kw Export VICTRIX Superior kw X Export

Typical Specifications For: ADVANTUS TM DOMESTIC HOT WATER SUPPLY Models AV(W)0500 AV(W)4000

Flue gas condensation...

GAS-FIRED FLOOR-STANDING BOILERS

Power X High Power Condensing Wall-Hung Boilers

CAST IRON ATMOSPHERIC BOILERS

ALKON 90 ALKON 90 MODEL 24,0 93,6 21,1 87, nominal heat output. conventional. max/min heat input. efficiency class (Directive 92/42)

BWA. CONDENSING WALL HUNG BOILER FROM 50 kw TO 140 kw

Ideasandformsinevolution

wall-mounted boilers, water heaters and pool heaters floor standing boilers, water heaters and pool heaters

RMG MK. II RMG Mk.II RS Mk.II RMG Mk.II RS Mk.II

FEATURES AND BENEFITS. Up to 109.8% part load efficiency

Mynute Green k. Condensing Wall-Hung Boilers. Residential Heating

4FLOOR-STANDING GAS CONDENSING BOILERS

Light oil - kerosene burner

APEN GROUP SPA is a leading manufacturer of heating systems, who is active both in national and international ambits.

IMAX XTRA EL. 715kW FLOOR STANDING CONDENSING FEATURES AND BENEFITS

product Industrial burners Industrial burners sizes 30 to 70 flexible and reliable Information on oil, gas and dual fuel burners

AVIO kw Export 1 FEATURES. Wall-mounted with storage tank

KDE. PRESSURIZED STAINLESS STEEL CONDENSING BOILER FROM 124 kw TO 2160 kw

Power X High Power Condensing Wall-Hung Boilers

Bluehelix Tech RRT Wall-hung condensing boiler with Ferroli Thermobalance heat cell

Pure technology. Clean design and practical panel board with wide Power save display !DEA AR 23 !DEA RS !DEA AC 23 !DEA CS

MODULAR GAS CONDENSING UNIT EQUIPPED WITH PRIMARY RING and premix modulating Low NO x. from 100 to 900 kw and in battery up to 8 units

So old fashioned... As the combustion chamber is completely room sealed, it does not release any smells and does not dirty.

Divacondens D Plus Atmospheric condensation wall-mounted boilers, with instant domestic hot water production

Model FS GTB

24/31-28/35-33/40 kw Premix System Condensing Combi Gas Boilers. Priwa / PriwaPlus.

Exclusive Green E Condensing Wall-Hung Boilers

Forced draught gas burner

wall-mounted boilers, water heaters and pool heaters from 15 kw to 140 kw

Use, Installation and Maintenance Manual EMS-N/GH, EMS-K/GHK, EMS-R/GHR Warm Air Heater Module

24/31-28/35-32/40 kw Premix System Condensing Combi Gas Boilers. Priwa / PriwaPlus

High quality... SEALED PRE-MIXED MODULATING FAN SPECIAL METAL FIBRE BURNER FLAME DETECTION ELECTRODE IGNITION ELECTRODE FLUE OUTLET

GAS 610 ECO PRO. The new Remeha. Condensing Boiler Range REMEHA GAS 310/610 ECO PRO

SCR and SCR-ECO PREMIX CERAMIC HEATERS WITH MODULATION AND ON/OFF HEATING COOLING GREEN ENERGY RADIANT HEATING TECHNOLOGY AND INNOVATION

SAMPLE SPECIFICATION FOR RIELLO ARRAY MODULATING BOILER

thea 35 MR/MN Kondens Wall-mounted condensing boiler

Weishaupt WG10 and WG20 gas burners LN (Low NO x ) version 2/2002 CA

The iqe Boiler Range. Combination and System T Boilers.

TAHITI CONDENSING KR 55 - KR 85

Submittal Data GA Line AYF Series Commercial and Specialty Chiller-Heaters 2 or 4 pipe Gas Fired Absorption Chiller-Heater Cooling and Heating

C Elba Dual. Cast-iron, floor-standing boiler. High quality Italian product. Life-enhancing heat

Condensing, pre-mixed, wall-hung gas boilers with water tank

Seradens Super Seradens Super Plus

PRODUCT CATALOGUE

THE PERFECT CONDENSATION

Copper-Fin GAS-FIRED WATER HEATERS

ALKON CARGO. A precise and fast delivery rate. A very high specific flow rate (20 litres per minute with Dt 25)

RS /E-EV C01 SERIES

Mynute Green Condensing Wall-Hung Boilers

SPECIFICATIONS - NIKE

CI/SfB X. RHeco Series CONDENSING GAS FIRED UNIT HEATERS

Aluminium range of condensing boilers. Works every time. Designed to meet carbon reduction targets. Lifetime service and support

Wall hung combination

Euron. Compact Wall Mounted Gas Fired Condensing Boilers and Combis with Outputs 24kW - 30kW BOILERS

Submittal Data GAHP Line W LB Series Ground Source Gas Fired Absorption Heat Pump Heating and Cooling

Weishaupt dual fuel burners Sizes 30 to 70 Version 1LN (NO X -reduction on gas operation) 1/2003 CA

SPECIFICATION GUIDE FLEXAIR. Possibility to add auxiliary heaters: Gas, Electrical Heater, Hot Water Coil Possibility to add Heat Recovery Module

General catalogue COMMERCIAL AND TECHNICAL INFORMATION. Commercial Range. March 2015 Edition

Transcription:

PCH/new Series High performance, total flexibility

PCH/new Installation in Air Handling Unit Very Low Emissions NOx lower than 30 ppm : Class 5 Capacity Range 14 models from 5 kw to 400kW Automatic Control Electonic ignition and simple elettrical connection Fine Tuning Standard power level managed by 0-10 volt control input from air handling unit Extended Modulation Standard continuous modulation from 100% to 20% Condensing Product 2

PCH/new Condensing Gas Heating Modules for Air Handling Units and Rooftops New Gas Modules PCH/new present an extended power range which goes from 5 kw to 400 kw. This result is achieved thanks to the possibility to assemble standard modules in parallel configuration. You can choose between three gas module configurations: A system: Single modules with max power between 5 kw to 100 kw. B system: Combined modules with horizontal /vertical parallel combination with max power between 13 kw to 400 kw. C system: Combined modules with horizontal parallel combination with max power between 13 kw to 200 kw. This complete product range is able to satisfy all heating needs of your air handling units and Roof Top packaged systems. PCH/new CAD rendering of Combustion Chamber and Heat Exchangers, premix burner and electronic board controls 3

PCH/new: gas condensing energy modules EFFICIENCY UP TO 109% Apen Group has designed and developed PCH/new heating modules for installation in air handling and roof-top units. PCH module is built with environment-friendly, totally recyclable materials, such as stainless steel and aluminium. The heat produced using PCH module s clean combustion is earth-friendly and convenient. A microprocessor-based device controls continuous modulation of thermal power output and adjusts it to heat requirements. When modulation of heat output is enabled, an advanced regulating device installed on the main burner monitors and adjusts flow rates of combustion air and gas. CLEAN COMBUSTION PCH /new condensation modules are equipped with burners that fully premix air and gas. Moreover, a regulating device of heat output is installed. This results in: - NO emissions of carbon monoxide (CO = 0); - Very low emission of nitrogen oxides, below 30 parts per million (NOx < 30 ppm); - Low emission of carbon dioxide, due to high combustion efficiency (109%) and to reduction of fuel consumption arising from heat output modulation. UNDIRECT HEAT EXCHANGE The heat produced PCH is directly transferred to ambient air through undirect exchange with combustion products. These products flow inside a sealed system, totally separated from the air heated for environment. No intermediate fluid is required, so the hydraulic circuit is unnecessary and water freezing becomes an out-of-date issue. A few minutes are enough for the environment to warm up thanks to the absence of thermal inertia. NO NEED FOR A WATER BATTERY AND BOILER HEAT PLANT - Savings on plant building cost (boiler, burner, pumps, safety and regulation devices, masonry work); -Less space is required (units are smaller and require less clearance); -No need for plant certification (our PCH module is already fully certified). 4

PCH/new Features HEAT EXCHANGER Furnace and air/flue exchanger are entirely manufactured with stainless steel (with low carbon content) AISI 441 which assures maximum reliability and long life cycle. The new cylinder shaped furnace and the air/flue exchangers, whose tube bundle is custom designed, guarantee performance that place PCH/new modules among the leading units for heat efficiency, with an outstanding value of 109%. PREMIX BURNER The burner is entirely made of AISI 430 steel and undergoes specific engineering processing that guarantees top reliability and high thermal-mechanical performance. SAFETY AND CONTROL DEVICES The following devices are installed on PCH modules: 1. Safety thermostat with manual reset and positive safety; 2. Electronic ignition device for the burner and ionization flame control device; 3. Ignition and flame detection electrodes. ELECTRONIC CARD The microprocessor-based electronic card regulates continuous modulation of heat output and controls both the electrical fan for air/gas mixing and the gas valve. AIR/ MIXING: GUARANTEED SAFETY An advanced technique of air/gas mixing guarantees total safety. The gas valve delivers gas according to the air/gas ratio set at the premises. If combustion air fails, the gas valve shuts up. If combustion air decreases, the valve automatically reduces gas flow while maintaining optimal combustion parameters. CAD DRAWINGS When ordering a PCH/new module, ask for its size drawings. We supply drawings in 3D CAD format to ease your assembling work of the PCH module into your installation! DIRECTIVE CERTIFICATION Technical features of PCH module have been thoroughly checked and tested, then they have been approved and certified by KIWA TEC, the respected and renowned Body for European Certification. By assigning to PCH module the approval number 0694CP1457, KIWA TEC has certified that this modules comply with the following Directives: - 2009/142/CE - Directory on appliances burning gaseous fuels. - 2006/42/CE - Machinery Directive. - 2006/95/CE - Low Voltage Directive. - 2004/108/CE - Directive on Electromagnetic Compatibility. Condensing Product 5

PCH/new Technical Data (A system) Model PCH020 PCH034 PCH045 PCH065 PCH080 PCH105 Type of appliance B23P - B53P - C13 - C43 - C53 - C63 - C83 CE approval PIN. 0476CQ0451 NOx class Val 5 min max min max min max min max min max min max Rated thermal input (hi) kw 4,75 19,00 7,60 34,85 8,50 42,00 12,40 65,00 16,40 82,00 21,00 100,00 Rated thermal output kw 4,97 18,18 8,13 33,56 8,97 40,45 13,40 62,93 17,77 80,03 22,77 97,15 Efficiency hi (p.c.i) % 104,63 95,68 106,97 96,30 105,50 96,30 108,06 96,82 108,35 97,60 108,40 97,15 Efficiency hs (p.c.s) % 94,26 86,20 93,37 86,76 95,07 86,76 97,36 87,22 97,62 87,93 97,68 87,52 Chimney loss - burner ON (hi) % 0,4 4,3 0,6 3,7 0,5 3,7 0,2 3,2 0,3 2,4 0,2 2,8 Chimney loss - burner OFF (hi) % < 0,1 < 0,1 < 0,1 < 0,1 < 0,1 < 0,1 Casing heat loss (1) 0% 0% 0% 0% 0% 0% Max. Condensation produced (2) l/h 0,4 0,9 1,1 2,1 3,3 2,7 Carbon monoxide C0 (0% di O 2 ) (3) ppm < 5 < 5 < 5 < 5 < 5 < 5 Nitrogen oxides - NOx - (0% di 0 2 ) (4) 38 mg/kwh 22 ppm 42 mg/kwh 24 ppm 33 mg/kwh 19 ppm 39 mg/kwh 22 ppm 32 mg/kwh 18 ppm Available flue pressure Pa 80 90 100 120 120 120 Power supply V 230 Vac - 50 Hz monophase 41 mg/kwh 23 ppm Power absorbed W 12 45 11 74 15 65 15 97 40 123 20 130 Power absorbed in stand by W < 5 IP protection IP IP X5D Working temperature C From -15 c to +40 c - (for lower temparatures order heating burner box electrical resistance kit) Ø Gas connection G 3/4" G 3/4 G 3/4 G 3/4 G 3/4 G 3/4 Ø of air inlet/exhaust pipes mm 80/80 80/80 80/80 80/80 80/80 80/80 Minimum air flow (5) m 3 /h 1.900 3.500 4.200 6.500 8.200 10.000 Max applicable pressure Pa 1.200 1.200 1.200 1.200 1.200 1.200 Net weight kg 39 48 58 72 98 118 NOTE: (1) The casing heat losses are the same as those of the machine which contains the PCH. (2) Max. Condensation produced value obtained by test at 30% Nominal load (Qn). (3) Value reference with gas cat. H (G20). (4) Value (statistical medium calculation) EN1020 reference gas cat. H (G20), based on Net calorific value (Hi). (5) Minimun air flow has been calculated for a t value of 28 C. For process plants or special applications, with t value > 28 C, please contact Apen Group. 6

PCH/new Dimensions (A system) Dimensions (mm) Model B H L H1 H2 H3 L1 L2 L3 E G A S C PCH020 710 450 660 534 PCH034 950 690 PCH045 450 730 604 63 - PCH065 1.250 990 230 47 2X Ø21 3/4'' Ø 80 Ø 80 ½'' PCH080 1.440 1.180 815 689 PCH105 1.670 1.410 1'' 7

PCH/new Technical Data (B system) Model PCH130 PCH160 PCH210 PCH320 PCH420 Type of appliance B23P - B53P - C13 - C43 - C53 - C63 - C83 CE approval PIN. 0476CQ0451 NOx class Val 5 min max min max min max min max min max Rated thermal input (hi) kw 12,40 130,00 16,40 164,00 21,00 200,00 21,00 300,00 21,00 400,00 Rated thermal output kw 13,40 125,86 17,77 160,06 22,77 194,30 22,77 291,45 22,77 388,60 Efficiency hi (p.c.i) % 108,06 96,82 108,35 97,60 108,40 97,15 108,40 97,15 108,40 97,15 Efficiency hs (p.c.s) % 97,36 87,22 97,62 87,93 97,68 87,52 97,68 87,52 97,68 87,52 Chimney loss - burner ON (hi) % 0,2 3,2 0,3 2,4 0,2 2,8 0,2 2,8 0,2 2,8 Chimney loss - burner OFF (hi) % < 0,1 < 0,1 < 0,1 < 0,1 < 0,1 Casing heat loss (1) 0% 0% 0% 0% 0% Max. Condensation produced (2) l/h 4,2 6,6 5,4 8,1 10,8 Carbon monoxide C0 (0% di O 2 ) (3) ppm < 5 < 5 < 5 < 5 < 5 Nitrogen oxides - NOx - (0% di 0 2 ) (4) 39 mg/kwh 22 ppm 32 mg/kwh 18 ppm 41 mg/kwh 23 ppm 41 mg/kwh 23 ppm Available flue pressure Pa 120 120 120 120 120 Power supply V 230 Vac - 50 Hz monophase 41 mg/kwh 23 ppm Power absorbed W 30 194 80 246 40 260 60 390 80 520 Power absorbed in stand by W < 5 IP protection IP IP X5D Working temperature C From -15 c to +40 c - (for lower temparatures order heating burner box electrical resistance kit) Ø Gas connection G 1½ G 1½ G 1½ 1 x G 1½ + 1 x G ¾ 2 x G 1½ Ø of air inlet/exhaust pipes mm 2 x 80/80 2 x 80/80 2 x 80/80 3 x 80/80 4 x 80/80 Minimum air flow (5) m 3 /h 13.000 16.400 20.000 30.000 40.000 Max applicable pressure Pa 1.200 1.200 1.200 1.200 1.200 Net weight kg 154 206 250 375 500 NOTE: (1) The casing heat losses are the same as those of the machine which contains the PCH. (2) Max. Condensation produced value obtained by test at 30% Nominal load (Qn). (3) Value reference with gas cat. H (G20). (4) Value (statistical medium calculation) EN1020 reference gas cat. H (G20), based on Net calorific value (Hi). (5) Minimun air flow has been calculated for a t value of 28 C. For process plants or special applications, with t value > 28 C, please contact Apen Group. PCH 130/160/210 PCH 320 PCH 420 8

PCH/new Dimensions (B system) Dimensions (mm) Model B H L H1 H2 H3 L1 L2 L3 E G A S C PCH130 740 PCH160 1.050 PCH210 PCH320 825 1.575 1.260 1.000 1.450 1.190 418 53 108 1.680 1.420 230 47 2X Ø21 G 1 ½ 1xG 1 ½ + 1xG ¾ 2X Ø 80 3X Ø 80 2X Ø 80 3X Ø 80 1 X ½'' PCH420 2.100 2xG 1 ½ 4X Ø 80 4X Ø 80 9

PCH/new Technical Data (C system) Model PCH132 PCH162 PCH212 Type of appliance B23P - B53P - C13 - C43 - C53 - C63 - C83 CE approval PIN. 0476CQ0451 NOx class Val 5 min max min max min max Rated thermal input (hi) kw 12,40 130,00 16,40 164,00 21,00 200,00 Rated thermal output kw 13,40 125,86 17,77 160,06 22,77 194,30 Efficiency hi (p.c.i) % 108,06 96,82 108,35 97,60 108,40 97,15 Efficiency hs (p.c.s) % 97,36 87,22 97,62 87,93 97,68 87,52 Chimney loss - burner ON (hi) % 0,2 3,2 0,3 2,4 0,2 2,8 Chimney loss - burner OFF (hi) % < 0,1 < 0,1 < 0,1 Casing heat loss (1) 0% 0% 0% Max. Condensation produced (2) l/h 4,2 6,6 5,4 Carbon monoxide C0 (0% di O 2 ) (3) ppm < 5 < 5 < 5 Nitrogen oxides - NOx - (0% di 0 2 ) (4) 39 mg/kwh 22 ppm 32 mg/kwh 18 ppm 41 mg/kwh 23 ppm Available flue pressure Pa 120 120 120 Power supply V 230 Vac - 50 Hz monophase Power absorbed W 30 194 80 246 40 260 Power absorbed in stand by W < 5 IP protection IP IP X5D Working temperature C From -15 c to +40 c - (for lower temparatures order heating burner box electrical resistance kit) Ø Gas connection G 1½ G 1½ G 1½ Ø of air inlet/exhaust pipes mm 2 x 80/80 2 x 80/80 2 x 80/80 Minimum air flow (5) m 3 /h 13.000 16.400 20.000 Max applicable pressure Pa 1.200 1.200 1.200 Net weight kg 148 200 240 NOTE: (1) The casing heat losses are the same as those of the machine which contains the PCH. (2) Max. Condensation produced value obtained by test at 30% Nominal load (Qn). (3) Value reference with gas cat. H (G20). (4) Value (statistical medium calculation) EN1020 reference gas cat. H (G20), based on Net calorific value (Hi). (5) Minimun air flow has been calculated for a t value of 28 C. For process plants or special applications, with t value > 28 C, please contact Apen Group. 10

PCH/new Dimensions (C system) Dimensions (mm) Model B H L H1 H2 H3 L1 L2 L3 E G A S C PCH132 1.460 1.250 604 990 PCH162 450 1.440 63 126 1.180 1.630 689 PCH212 1.670 1.410 230 47 2X Ø21 1 ½'' 2X Ø 80 2X Ø 80 1 X ½'' 11

PCH/new Air flow rate- Pressure drop chart 180 A --Moduli Single Modules singoli 160 PCH020 PCH034 PCH045 PCH065 PCH080 140 PCH105 120 P [Pa] 100 80 60 40 20 0 1500 3500 5500 7500 9500 11500 13500 15500 17500 19500 Portata Air Flow Aria a 15 C (m[m 3 /h) 3 /h] 180 B B - Moduli - Horizontal composti Combined orizzontalmente Modules PCH130 PCH160 PCH210 PCH320 160 140 120 PCH420 P [Pa] 100 80 60 40 20 0 5000 7000 9000 11000 13000 15000 17000 19000 21000 23000 25000 27000 29000 31000 33000 35000 37000 39000 41000 43000 45000 Portata Air Flow Aria 15 C a 15 C (m[m 3 /h) 3 /h] 180 C C - Moduli - Vertical composti Combined verticalmente Modules PCH132 PCH162 160 140 PCH212 120 P [Pa] 100 80 60 40 20 0 9500 11500 13500 15500 17500 19500 21500 23500 25500 27500 29500 31500 33500 Portata Air Flow Aria 15 C a 15 C (m[m 3 /h) 3 /h] 12

PCH/new Air flow rate-throughput speed chart 7 A A - Single -Moduli Modules singoli 6 PCH020 PCH034 PCH045 PCH065 PCH080 PCH105 5 Speed Velocità (m/s) [m/s] 4 3 2 1 0 0 5.000 10.000 15.000 20.000 25.000 Portata Air Flow Aria 15 C a 15 C (m[m 3 /h) 3 /h] 7 B -Moduli - Horizontal composti Combined orizzontalmente Modules 6 PCH130 PCH160 PCH210 PCH320 PCH420 5 Speed Velocità (m/s) [m/s] 4 3 2 1 0 5.000 10.000 15.000 20.000 25.000 30.000 35.000 40.000 45.000 Portata Air Flow Aria 15 C a 15 C (m 3 [m /h) 3 /h] 7 C -Moduli - Vertical composti Combined verticalmente Modules 6 PCH132 PCH162 PCH212 5 Velocità Speed (m/s) [m/s] 4 3 2 1 0 5.000 10.000 15.000 20.000 25.000 30.000 35.000 40.000 45.000 Portata Air Flow Aria 15 C a 15 C (m[m 3 /h) 3 /h] 13

14

15

APEN GROUP S.p.A. 20060 Pessano con Bornago (MI) - Italy Via Isonzo, 1 (ex Via Provinciale, 85) Phone +39-02-95.96.93.1 Fax +39-02- 95.74.27.58 www.apengroup.com apen@apengroup.com Cod. X01483GB ed 1510 - Specifications in this marketing catalogue are subject to change without notice, require technical istruction manual for specific desing purpouse.