Operator s Manual. IP-100 Immersion Probe Cooler

Similar documents
Operator s Manual. Histology Bath

Operator s Manual General Purpose Water Baths

150 SERIES VACUUM SEALING SYSTEM

Operators Manual. Microprocessor Controlled. Water Baths

Operators Manual. Microprocessor Controlled. Water Baths

AIR CONDITIONER ELECTRONIC CONTROL

Outdoor Refrigerator USER S MANUAL

SLIDER CASEMENT AIR CONDITIONER

ROTARY CONTROL AIR CONDITIONER

Portable Air Conditioner 6,000 BTU 8,000 BTU 10,000 BTU

5) Do not start or stop the unit by inserting or pulling out the power plug.

Model No.: PS08-01 PS10-01 Ref: KY80 KY100

1 HP Air Mover. Owner s Manual

Outdoor/Commercial Refrigerator USER S MANUAL

MEDICAL FREEZER. Model FS24L INSTRUCTION MANUAL. Write Serial Number (on back of unit) here:

Horizontal Bottle Cooler Installation and Operation Manual

Ui REFRIGERATOR SPEC SHEET

UNIT MODEL/ POWER SUPPLY VOLTAGE VARIATION AMBIENT AIR ON CONDENSER

Digital Heat Block User Manual

SPA BLOWER OWNER'S MANUAL XXXX, XXXX, XXXX, XXXX, XXXX, XXXX fax

IW-25-2 Dehumidifier Installation & Operations. Manual

Glass Door Refrigerators

Portable Evaporative Air Cooler for Outdoor, Indoor & Commercial Use. OWNER'S MANUAL Read and save these instructions before use.

Because you re not like everyone else. EVAPORATIVE COOLER EC220W OWNER S MANUAL

Superdryer Dehumidifiers

Turbo Air Speed up the Pace of Innovation TBB-4SB CAUTION! PLEASE KEEP POWER SWITCH ON BEFORE OPERATING THIS EQUIPMENT

Owner s. Coolerr. comply. To view

Instruction Manual Item No.: V~, 60Hz

REFRIGERATED DROP-INS (2-6)FT-DI Installation and Operating Manual

Instruction Manual. For All Corning Hot Plates, Stirrers, Stirrer/Hot Plates with Digital Displays, and External Temperature Controller (6795PR)

Air Cleaning Equipment, Inc. 303 N. Main St. Broadway, NC iers.com

Use & Care. Room Air Conditioner. All about the. of your TABLE OF CONTENTS. Normal Sounds... 4 Major Appliance Limited Warranty...

Blue Air. Commercial Refrigeration Inc. Installation & Operation Manual Ice Cream Freezers

Installation & Operation Manual Ice Cream Freezers

1.7 CU.FT. REFRIGERATOR INSTRUCTION MANUAL MCBR170BMD

FTC-350A. ual. Instruction and Operation Manual. Thermo NESLAB Manual P/N Rev. 11/08/00

Portable Dehumidifier with Internal Pump

4.5 CU.FT. REFRIGERATOR INSTRUCTION MANUAL

Operating Instructions

Portable Air Conditioner and Heater With Heat Pump Technology Operating Instructions. Model No.: PH3-12R-03 Reference No.: KY2-34

2.4 Cu. Ft. Compact Refrigerator

Portable Air Conditioner with Heat Pump Technology PH4-10R-01, PH4-12R-01, & PH4-14R-01 Operating Instructions

User Manual / Installation Instructions

Operation Manual Vortex mixer unitexer 1

CFC-FREE CB-60/CB-80 Cryobath Low Temperature Bath. Thermo NESLAB Manual P/N U00551 Rev. 04/03/00. Instruction and Operation Manual

LGR Dehumidifier Owner s Manual

BEFORE USE, PLEASE READ AND FOLLOW ALL SAFETY RULES AND OPERATING INSTRUCTIONS

POLAR TEMP FARM MORTALITY UNIT OPERATION MANUAL

Portable Air Conditioner with Heat Pump Technology Operating Instructions. Model No.: HCB-P13HP-D. Reference No.: BPD13HP V140217

OUTDOOR ICE MAKER Model BIM24OS

Portable Air Conditioner, Dehumidifier,Heater and Fan utilizing Heat Pump Technology

WET/DRY VACUUM. QUEST for Continuous Improvement Windsor s Quality Management System is Certified ISO MODEL: T1. Operating Instructions (ENG)

READ MANUAL BEFORE OPERATING SYSTEM Read the owner s manual thoroughly before operating to ensure the most efficient use of the system.

11,000 BTU Portable Air Conditioner with dehumidifier & Fan PE4-11R-03 Operating Instructions. Model No. PE4-11R Soleus Air International

Portable Air Conditioner with Evaporative Technology PE6-10R-03 Operating Instructions. Model No. PE6-10R Soleus Air International

Model No. PE2-07R / PE2-09R / 9000 BTU Portable Air Conditioner with dehumidifier & Fan PE2-07R-62 / PE2-09R-32 Operating Instructions

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MM14CHCS. Voltage rating: 115V~60Hz Power rating : 1400W

Document No

Operator s Manual. The Bullet Blender 50 BB50-AU, BB50-DX. Contents. Congratulations!

WINDOW/WALL-TYPE ROOM AIR CONDITIONER

12,000 BTU Portable Air Conditioner PE3-12R-03. Model No. PE3-12R Soleus Air International

Whynter Portable Ice Maker 33 lb capacity - White

WHYNTER Compressor Cooling Beverage Refrigerator - Stainless Steel

Milk Coolers Installation and Operation Manual Please read this manual completely before attempting to install or operate this equipment!

Installation, Operation & Service Manual

Instruction Manual Item No.: V~, 60Hz

WA A Aqua Sub Bottom-load Water Cooler

Instruction Manual. Model AccuPlate Hotplate AccuPlate Stirrers AccuPlate Hotplate Stirrer 12/10 CLS-EQ-LHP01REV

Dehumidifiers. Déhumidificateur. Deshumedificador. GEAppliances.com. Safety Instructions... 2, 3. Owner s Manual

2kW UPRIGHT FAN HEATER INSTRUCTIONS FOR USE

CHEST FREEZER INSTRUCTION MANUAL. Model No.: EWCF5WBX EWCF7WBX

Panel Mounted Heat Exchangers by Dantherm, Inc.

DEHUMIDIFIER. User Manual 50BT, 70BT

WMWLB / WMWFM / WTWLB / WTWFM Series Hydronic Heating Unit

OPERATION MANUAL. CLASSIC 10 and CLASSIC 18 SERIAL NUMBER FROM JANUARY 2009 (0109) TO PRESENT

ELECTRONIC CONTROL AIR CONDITIONER

Instruction Manual. Bottle Cooler. Models HBC-50 (-S) HBC-65 (-S) HBC-80 (-S) HBC-95 (-S) hoshizakiamerica.com. Issued: Revised:

CWR265SZ 26 Bottle Built-in Wine Cooler Owner s Manual

OWNER S MANUAL FOR MODELS DXA (Air-Automatic) DXM (Manual/Non-Air) DXH (Hydraulic Automatic) DXE (Electrical Mechanical Automatic)

RPI Industries, Inc.

Circulating Baths with Standard Digital Temperature Controller

OWNERS MANUAL MODEL 451 (-101 & -201)

CR13000-PAC OWNER S MANUAL. Portable Air Conditioner. PORTABLE AIR CONDITIONER with HEAT PUMP. Operating and Servicing Instructions

Reacti-Therm I and III Heating Modules

User s Guide for the SunDanzer BFRV55

14,000 BTU Portable Air Conditioner 14,200 BTU Heat Pump Model Number: LX-140 Operating Instructions. Model No. LX Soleus Air International

Portable Air Conditioner

Industrial Dehumidifier Operating Instructions. Model: VG 1500

GL-DEH Series Portable Dehumidifier Operating Instructions

Model No. GB-PAC-08E4. 8,000 BTU Portable Air Conditioner Operating Instructions

VENTLESS EXHAUST HOOD OPERATORS MANUAL AND PARTS LIST REV. MAY 2016

MODULAR REFRIGERATOR. Français p. 16 Español p. 31 ITEM # MODEL #BG179B

ELECTRIC STOVE HEATER Models: FS2213B

Model 1870F Dehumidifier Installation and Operating Manual

Owner s Manual. Operating Instructions The Controls on Your Dehumidifier Care of Product

!3 _!!ili_ '_:_i_;iii_ SG-PAC-12E1 SG-PAC- 12E 1HP. 12,000 BTU Portable Air Conditioner

BEFORE USE, PLEASE READ AND FOLLOW ALL SAFETY RULES AND OPERATING INSTRUCTIONS.

Portable Dehumidifier

PORTABLE AIR CONDITIONER

Filter Oven with Controller 101FRDC00-50 / 101FRDC00-CTRL

Transcription:

Operator s Manual IP-100 Immersion Probe Cooler 110-810 04.27.11

Table of Contents Introduction... 3 General Information... 3 General Safety Information... 3 Safety Recommendations... 4 Unpacking Your IP-100 Immersion Probe Cooler... 4 Regulatory Compliance & Testing... 4 Contents... 4 Controls & Components... 6 Quick-Start... 7 Installation & Startup... 8 General Site Requirements... 8 Positioning the Immersion Probe Assembly... 8 Electrical Power... 9 Normal Operation... 9 Turning Your IP-100 ON... 9 Main Operational Display... 10 Display Messages... 10 Loss of Power Restart... 10 Routine Maintenance & Troubleshooting... 11 Cleaning Exterior Surfaces... 11 Cleaning the Air Filter... 11 Draining Residual Oil from the Immersion Probe Assembly... 11 Troubleshooting... 12 Technical Information... 13 Performance Specifications... 13 Equipment Disposal (WEEE Directive)... 14 Service & Technical Support... 14 Warranty... 15 110-810 2

Introduction Your IP-100 Immersion Probe Cooler can be used to achieve low-temperature capability with nonrefrigerated circulating baths or boost the cooling capacity of refrigerated circulators. It is also excellent for trapping and Dewar-type applications, making it an economical alternative to dry ice or liquid nitrogen. A 6-ft. (1.83 m) flexible hose allows convenient placement of the cooling probe. It will take you very little time to get your IP-100 installed and running. This operator s manual is designed to guide you quickly through the process. We recommend that you read it thoroughly before you begin. NOTE: The IP-100 operates at maximum cooling performance. Maximum temperature stability will be achieved in an agitated fluid and with a constant heat load. Allow ample time to reach the lowest achievable temperature. General Information General Safety Information When installed, operated, and maintained according to the directions in this manual and common safety procedures, your IP-100 Immerson Probe Cooler should provide safe and reliable cooling. Please ensure that all individuals involved in the installation, operation, or maintenance of this unit read this manual thoroughly prior to working with the unit. This symbol marks chapters and sections of this instruction manual that are particularly relevant to safety. When attached to the unit, this symbol draws attention to the relevant section of the instruction manual. This symbol advises you of danger from electricity or electric shock. This symbol marks information that is particularly important. This symbol indicates alternating current. / These symbols on the Power Switch / Circuit Breaker indicate that they place the main power supply ON / OFF. This symbol on the Power Key indicates that it places the unit in a standby mode. It DOES NOT fully disconnect the unit from the power supply. This symbol indicates a protective conductor terminal. Read all instructions pertaining to safety, set-up, and operation. Proper operation and maintenance is the user s responsibility. 110-810 3

Safety Recommendations To prevent injury to personnel and/or damage to property, always follow your workplace s safety procedures when operating this equipment. You should also comply with the following safety recommendations: Always connect the power cord on this unit to a grounded (3-prong) power outlet. Make certain that the outlet is the same voltage and frequency as your unit. Never operate the unit with a damaged power cord. Always turn the unit OFF and disconnect Mains power before performing any maintenance or service. Never touch the immersion probe assembly while the unit is operating. Always allow the immersion probe to warm to ambient temperature before repositioning or working on the unit. Do not move the immersion probe assembly while the unit is operating. Unpacking Your IP-100 Immersion Probe Cooler Your IP-100 was packed in a special carton. You should keep the packaging, along with all packing materials, until the unit has been installed and you are certain it is working properly. IMPORTANT: Remove any loose packing material that may have clung to the base or wand assembly. CAUTION: Keep unit upright when moving. Be sure to follow your company s procedures and practices regarding the safe lifting and relocation of heavy objects. In the unlikely event that the unit was damaged or does not operate properly, contact the company where your IP-100 Immersion Probe Cooler was purchased. Regulatory Compliance & Testing CSA UL (60Hz units) CAN/USA C22.2 No 0-M91 General Requirement Canadian Electrical Code, Part II. CAN/USA C22.2 No. 61010-1-04 Safety Requirements for Electrical Equipment for Measurement, Control and Laboratory Use, Part I General Requirements. UL Std No. 61010-1 Electrical Requirements for Laboratory Use, Part I: General Requirements. CE (50Hz units) EC Low Voltage Directive 2006/95/EC EC Electromagnetic Compatibility Directive 2004/108/EC IEC 61010-1-2001 IEC 61326:2005 / EN 61326 : 2006 Highly Accelerated Life Test (HALT) and Vibration Tests per ASTM D4169-8 (All units) Contents 110-810 4

The following items have been included with your IP-100 Immersion Probe Cooler: Operator s Manual IEC Electrical Cord Certificate of Compliance 110-810 5

Controls & Components Temperature Display Power Key Air Filter Compartment Rigid Coil Immersion Probe Immersion Probe Assembly IMPORTANT: The temperature display is for reference only. The actual temperature of the immersion probe will be colder than the displayed temperature. Cold Finger Immersion Probe Flexible Immersion Probe Identification Label Power Switch / Circuit Breaker IEC Electrical Connection 110-810 6

Quick-Start 1 Position Immersion Probe 2 Connect power. See Identification Label. 3 Turn main power ON. 4 Turn Standby power ON. Allow approximately 10 minutes for the system to begin the cooling process. 5 Allow approximately 1 hour for system to reach -90 C. CAUTION: Moving Immersion Probe Cooler while unit is operating may result in damage. 110-810 7

Installation & Startup Your IP-100 Immersion Probe Cooler is designed to be simple to set-up and install. No tools are required. General Site Requirements Locate the unit on a level surface, free from drafts and out of direct sunlight. Do not place it where there are corrosive fumes, excessive moisture, high room temperatures, or where excessive dust is present. The IP-100 must be a minimum of 6 inches / 15.24 cm away from walls or vertical surfaces so that airflow around the unit is not restricted. It should not be placed in cabinets or where exiting warm air or warm air from other devices will be drawn into the air intake on the front of the unit. NOTE: It is recommended that your unit be run in ambient temperatures below 95 F / 35 C. While the unit will operate at higher ambient temperatures, it may not be able to achieve maximum cooling performance. Positioning the Immersion Probe Assembly When installing the IP-100, make sure that the Immersion Probe Assembly is properly positioned. It should not be twisted. Incorrect positioning of the Wand Assembly will cause your IP-100 to perform below specifications. CAUTION: Moving the Immersion Probe Assembly while the unit is operating may result in damage. 110-810 8

Electrical Power IMPORTANT INFORMATION FOR 100V APPLICATIONS: On 100V 50Hz applications a step-up transformer IS NOT NEEDED and MUST NOT be used. On 100V 60Hz applications a step-up transformer MUST be used. WARNING: Make certain that the electrical outlet is the same voltage and frequency as your IP-100. The correct voltage and frequency for your unit are indicated on the Identification Label on the back panel. IMPORTANT: The use of an extension cord is not recommended. If one is necessary, it must be properly grounded and capable of handling the total wattage of the unit. The extension cord must not cause more than a 10% drop in voltage to the unit. Attach the 6-ft / 1.8 m power cord to the IEC electrical connector on the back of the IP-100 and then plug the male connector into the Mains electrical outlet. Place the Power Switch / Circuit Breaker on the back of the IP-100 in the ON position. Three decimal points will appear on the Temperature Display. This indicates that the unit is in Standby mode. Your IP-100 is now ready to begin normal operation. Normal Operation Turning Your IP-100 ON Press the Power Key on the front panel. After a brief initialization message, the probe temperature will appear on the Temperature Display and the first stage compressor and fan will turn on to begin the cooling process. During this start-up phase, the displayed temperature will remain near or at ambient temperature. After approximately 10 minutes, the second stage compressor will turn on, refrigerant will begin circulating through the system, and the displayed temperature will begin decreasing. It generally takes approximately 60 minutes from power up for the IP-100 to reach -90 C. NOTE: The IP-100 operates at maximum cooling performance. IMPORTANT: To protect the IP-100 s compressors from damage, the unit incorporates a special safety switch that delays compressor startup for 10 minutes whenever power is applied. This 10 minute delay will occur even when power is only momentarily disrupted. 110-810 9

Main Operational Display The actual temperature of the IP-100 s immersion probe is displayed in degrees C on the unit s digital readout. Due to the location of the temperature sensor, this temperature is a few degrees warmer than the surface temperature of the immersion probe. Display Messages Temperature Display Description Standby Mode Indicates that the Power Switch / Circuit Breaker on the back panel is in the ON position and unit is ready to operate. Power On / Start-Up Appears briefly when IP-100 is turned ON by pressing the Power Key on the front panel. The information represents the firmware version. Main Operational Display Indicates IP-100 is ON and operating. Displayed temperature is in degrees C. Note: Displayed temperature is to one tenth of a degree (X..X) until it reaches -10. Warning Display Indicates that the external temperature sensor is not functioning properly. Unit will continue to cool. Loss of Power Restart In the event that electrical power is disrupted during operation, the unit will begin operating automatically when power is restored. As with normal start-up, it will take approximately 60 minutes for the unit to reach -90 C. 110-810 10

Routine Maintenance & Troubleshooting Cleaning Exterior Surfaces Only mild detergents and water or an approved cleaner should be used on the painted surfaces of the IP- 100. Do not allow cleaning liquids or sprays to come in direct contact with the digital display. Cleaning the Air Filter To keep the refrigeration system operating at optimum cooling capacity, the front and back air vents and reusable filter should be kept free of dust and dirt. They should be checked on a scheduled basis and cleaned as required. The reusable filter is easily accessed by simply sliding it out of the side of the front grill. Use a mild detergent and water solution to wash off any accumulated dust and dirt and then rinse and dry thoroughly before reinstalling. Draining Residual Oil from the Immersion Probe Assembly A thin film of oil may build up within the Immersion Probe Assembly with extended use and adversely affect the IP-100 s cooling efficiency. To ensure maximum cooling performance, we recommend that this oil be drained from the Immersion Probe Assembly after every 200 hours of use or whenever you see a drop in cooling performance. 1. Place the IP-100 in the Standby mode by pressing the Power Key on the front panel. 2. Elevate the Immersion Probe Assembly as high as possible above the IP-100 s enclosure for 10 to 15 minutes to allow residual oil to drain back into the compressor. Do not allow the assembly to twist or dip as oil may pool internally in these areas. CAUTION: Moving Immersion Probe Assembly while unit is operating may result in damage. IMPORTANT: Should you experience frequent drops in cooling performance due to the accumulation of oil in the Immersion Probe Assembly, verify that it is properly installed, without any twists. See Positioning the Immersion Probe Assembly under Installation & Startup. 110-810 11

Troubleshooting CAUTION: Always turn the Power Switch / Circuit Breaker OFF and disconnect the electrical cord from the power source before servicing the unit. Problem Cause Corrective Action Unit does not run (Temperature Display is blank) Unit does not run (Three decimals on Temperature Display) Unit does not run (Temperature Display reading increasing or at ambient) No or insufficient cooling Gradual loss of cooling Compressor shakes, stalls, or continually restarts No power to unit Power Switch / Circuit Breaker in OFF position Unit in Standby mode Compressor overload switch has tripped Blocked air flow High ambient temperature Oil in Immersion Probe Assembly Improper line voltage and/or frequency Blocked air flow High ambient temperature Oil in Immersion Probe Assembly Compressor cycling or overloaded Check that electrical cord is secure and plugged into an operating electrical outlet. Place Power Switch / Circuit Breaker in ON position. Press Power Key on front panel. Allow approximately 10 minutes for unit to restart. Check air filter and air vents for blockages. Check that airflow around unit is not restricted and that room temperatures does not exceed 95 F / 35 C. Check compressor fan for operation (listen for fan noise, check for airflow through unit). Check air filter and air vents for blockages. Check that airflow around unit is not restricted and that room temperatures does not exceed 95 F / 35 C. Drain oil from Immersion Probe Assembly. Verify that Mains voltage during start cycle is within 10% of rated voltage. Check air filter and air vents for blockages. Check that airflow around unit is not restricted and that room temperatures does not exceed 95 F / 35 C. Drain oil from Immersion Probe Assembly. Check air filter and air vents for blockages. Check that airflow around unit is not restricted and that room temperatures does not exceed 95 F / 35 C. Verify that Mains voltage during start cycle is within 10% of rated voltage. Check compressor fan for operation (listen for fan noise, check for airflow through unit). 110-810 12

Technical Information Performance Specifications Temperature Set Point: Readout Accuracy: Compressors: Cooling Probe Assembly: Cooling Probe: Dimensions (H x W x D): -100 C (non-adjustable) ±1.0 C Two nominal ½ HP low back pressure reciprocating compressors 6 ft. / 1.83 m flexible hose Rigid Coil: 3 in. / 76.2 cm diameter; 8.75 in. / 22.2 cm length Cold Finger: 0.75 in. / 1.91 cm diameter; 3.75 in. / 9.53 cm length Flexible: 0.625 in. / 1.59 cm diameter; 15 in. / 38.1 cm length 21 x 15 x 20.125 in. / 53.34 x 38.1 x 51.12 cm Electrical Requirements: 120V, 60Hz, 11.5A 240V, 50Hz, 7.5A 100V, 50Hz, 11.5A 100V, 60Hz, 11.5A (step-up transformer required) Environmental Conditions: For indoor use only Maximum altitude: 6562 ft. / 2000 m Relative humidity: 80% for temperatures up to 95 F / 35 C Over voltage: ±10% Nominal ambient: 68 F / 20 C Maximum recommended operating ambient: 95 F / 35 C Installation Category II Pollution Degree 2 IMPORTANT INFORMATION FOR 100V APPLICATIONS: On 100V 50Hz applications a step-up transformer IS NOT NEEDED and MUST NOT be used. On 100V 60Hz applications a step-up transformer MUST be used. 110-810 13

Equipment Disposal (WEEE Directive) or This equipment is marked with the crossed out wheeled bin symbol to indicate it is covered by the Waste Electrical and Electronic Equipment (WEEE) Directive and is not to be disposed of as unsorted municipal waste. Any products marked with this symbol must be collected separately, according to the regulatory guidelines in your area. It is your responsibility to correctly dispose of this equipment at lifecycle-end by handing it over to an authorized facility for separate collection and recycling. It is also your responsibility to decontaminate the equipment in case of biological, chemical and/or radiological contamination, so as to protect the persons involved in the disposal and recycling of the equipment from health hazards. By doing so, you will help to conserve natural and environmental resources and you will ensure that your equipment is recycled in a manner that protects human health. Requirements for waste collection, reuse, recycling, and recovery programs vary by regulatory authority at your location. Contact your local responsible body (e.g., your laboratory manager) or authorized representative for information regarding applicable disposal regulations. Service & Technical Support If you have followed the troubleshooting steps and your IP-100 Immersion Probe Cooler fails to operate properly, contact the distributor or manufacturer from whom the unit was purchased. Have the following information available for the customer service person. Model, Serial Number, and Voltage (from back panel) Date of purchase and your purchase order number Suppliers' order number or invoice number A summary of your problem 110-810 14

Warranty The manufacturer s warranty is one year for parts and labor and two years for parts. Please contact your supplier for additional warranty details and service contract information. The manufacturer agrees to correct for the original user of this product, either by repair, or at the manufacturer's election, by replacement, any defect that develops after delivery of this product for the warranty period(s) stated above. In the event of replacement, the replacement unit will be warranted for 90 days or warranted for the remainder of the original unit s parts or labor warranty period, whichever is longer. If a replacement unit is sent, the defective unit must be returned to the manufacturer within 30 days of receipt of the replacement unit. If the defective unit is not received within 30 days, the manufacturer reserves the right to bill for the replacement unit. If this product requires service, contact the manufacturer/supplier's office for instructions. If return of the product is necessary, a return authorization number will be assigned and the product should be shipped, (transportation charges pre-paid), to the indicated service center. To insure prompt handling, the return authorization number should be placed on the outside of the package and a detailed explanation of the defect enclosed with the item. This warranty shall not apply if the defect or malfunction was caused by accident, neglect, unreasonable use, improper service, or other causes not arising out of defects in material or workmanship. There are no warranties, expressed or implied, including, but not limited to, those of merchantability or fitness for a particular purpose which extends beyond the description and period set forth herein. The manufacturer's sole obligation under this warranty is limited to the repair or replacement of a defective product and shall not, in any event, be liable for any incidental or consequential damages of any kind resulting from use or possession of this product. Some states do not allow: (A) limitations on how long an implied warranty lasts; or (B) the exclusion or limitation of incidental or consequential damages, so the above limitations or exclusions may not apply to you. This warranty gives you specific legal rights. You may have other rights that vary from state to state. Manufactured by: PolyScience 6600 W. Touhy Avenue Niles, IL 60714 U.S.A. 1-800-229-7569 1-847-647-0611 www.polyscience.com 110-810 15