Hudevad Plan. Technical datasheet

Similar documents
Hudevad P5. Technical datasheet

P r o d u c t c a t a l o g u e

P r o d u c t c a t a l o g u e

Metropolitan high output natural and powered trench heaters

LOW SURFACE TEMPERATURE RADIATORS

Heating and cooling ceiling systems Suspended ceiling systems. Heating Cooling Fresh Air Clean Air

UK PRICE GUIDE. January Complete with Technical Specifications for ROUND TOP, COMPACT, LST, AND TOWEL RADIATORS

CASSETTE UNIT. Comfort Circle

Heating. Our range of designer radiators and towel rails, brings fashion and function together beautifully. By Style

2 DESCRIPTION OF SYSTEM COMPONENTS

Heating Emitters. Find the right radiator for each room. Radiators Towel Warmers Towel Warmer Valves 295

Cooling and heating systems. Static cooling ceiling system SKS-5/3 for visible installation

DC340 Rack and pinion door closer with guide rail or link arm

ALTO DRAWER SYSTEMS .hafele.com.au Dimensions in mm 2018 www

Type CODE Speed Heating Cooling

SPECIFICATION GUIDELINE FROST PROTECTION FOR PIPES. Tender Specification. Engineering Specification for Pipe Frost Protection. Contents.

INTRODUCTION HOW DO RADIANT PANELS WORK? A common misconception, even among heating professionals, is that heat rises. In fact, hot air rises and cold

Panel Radiators. Installation and operating instructions. ThermaRad Classic.

Radiators, Towel Warmers and Trench Heating

BELGRAVIA Classic (Vertical Units) - Technical Data Sheet

Showering Brassware Collections

UK 01/2014 BEAMS COLLECTION VASCO ALUMINIUM RADIATOR

RM530WC+ DIAL EXPOSED THERMO SHOWER VALVE INSTALLATION INSTRUCTIONS

Installation instructions Page 12. Multi-temperature wine cabinet EWTdf 1653 / 2353 / 3553

shower panel specification manual 2008

CR A-F-A-E-HQQE 3x400/ HZ

Environmental and oil cabinets The optimum storage area for liquids

VARICOOL Velum. System description/applications 4 Design and application 5 Planning and dimensioning 7 Technical features 8

Optimal work climate with open doors. Industrial air curtains Model IndAC

at in Bathroom radiators are where fashion and function come together in perfect harmony. With everything

food service tapware Pre-Rinse Assemblies HEAVY DUTY FIT FOR PURPOSE PERFORMANCE AND EFFICIENCY Hands Free Foot & Knee Operated Tapware

Thermostatic valves with radiator connection systems

Installation Instructions and User Guide. Thermostatic Recessed Dual Control Shower Valve. Models covered: CAS SHCVO C, COB SHCVO C, ORB SHCVO C,

COMPONENT SOLUTIONS for the lighting industry

ECOLEC PANEL HEATERS GENERAL NOTES.

Aluminium Curtain Tracks

T6 - Centrally Connected & VONOPLAN T6.

TC MODULE (FFD) (with Gas Hob)

(UK) Date : February 2016 NOTE: PLEASE LEAVE COPIES OF THESE INSTRUCTIONS AND ANY DRAWINGS WITH THE END USER.

ALTO DRAWER SYSTEMS. exclusively Brought to you by Häfele.

INSTALLATION MANUAL ESM9+ / ESM11+ / ESM15+

PANEL RADIATORS DESIGN RADIATORS TOWEL WARMERS.

X62 Tap Range. Please keep these instructions for future reference

BLADE BATH SHOWER MIXER DECK MOUNTED CHR WITH KIT INSTALLATION INSTRUCTIONS P BS-E A/2

Cold water HD 9/18-4 ST

GENERAL FITTING GUIDE THERMOSTATIC BAR SHOWER MIXER with RIGID RISER KIT

Commercial Heating Domestic Heating

The new WAREMA external venetian blind 80 S PROVEN THINGS IN PERFECTION

07/ OUR COLLECTION OF DESIGNER RADIATORS AND TOWEL RAILS INSPIRE WARMTH AND ELEGANCE IN ANY BATHROOM. HEATING20. guarantees unless otherwise stated

CR A-F-A-E-HQQE 3x400/ HZ

Sovereign Double CC/DD

Varsity Concealed Shower System

User Manual for Separera 30

ARCHITECTURAL ELEMENTS CUBICLES

DC200 Rack and pinion door closer with link arm

Parenzo Range. Basin Mixer, Bath Filler & Bath Shower Mixer. Assembly instructions

Flow Solutions Valves for Heating System Control

doc.m rimless super pack

Convectors Steam / Hot Water November, 2009

CRN A-F-G-E-HQQE 3x400D 50 HZ

planal vertical The ultimate modern statement room, Planal Vertical radiators and exciting, flexible way to make an impression

CR64-1 A-F-A-E-HQQE 3x400D 50 HZ

CR A-F-A-V-HQQV 3x400D 50 HZ

CR A-F-A-E-HQQE 3x400D 50 HZ

CR32-4 A-F-A-E-HQQE 3x400D 50 HZ

Shading Tension Systems

NOVA PRO drawer system

CRN90-1 A-F-G-V-HQQV 3x400D 50 HZ

CHILDRENS TOILETS. Junior Series WC and Pan. Junior Series - Technical. Designer bathroom suites - miniaturized!

Aquatique. Shower heads. Fixed and adjustable height heads. Aquatique shower kits installation guide page 1

Kenya s Official Distributor of GutterFlow Products

[ KoRALIne. FRee StAnDInG ConVeCtoRS (natural convection)

OPTIMIZED CONVECTION. unique heating technology. Catalogue

enviroblinds external blinds & shutters the secret to low carbon comfort

at in Bathroom radiators are where fashion and function come together

Cast Iron Radiators. General Information 2. Block make up 6.

Electric Cast Iron Radiators

THE PERFECT CHOICE FOR YOUR HOME

CHILLED ROOM AIR CURTAIN. IsolAir

CONCEALED THERMOSTATIC TOUCH SHOWER MIXER VALVE Installation & Aftercare Instructions (1) (2) PLEASE READ BEFORE INSTALLATION

Multilux 4-Eclipse-Set

DC300 Rack and pinion door closer with link arm

Our Guarantee. The key to good service is communication. We believe this starts from that first call until the kitchen is in full operational use.

liniled Handrail IK10 A I S I 316 UV RESISTANT RoHS IP40/IP65 CLEANING AGENTS RESISTANT FROST RESISTANT

Victory Home Improvements

Linea Plus. Freestanding. Jaga Heating Products (UK) Ltd T: +44 (0) F: +44 (0)

Floor Heating & Heated Towel Rails Product Catalogue

Aquamixa. Thermo. Thermostatic shower valve with manual bath fill

Photography: Wenzel SHOP AND OFFICE FITTINGS TECHNAL SYSTEM AND FURNITURE

CR20-07 A-F-A-E-HQQE 3x400/ HZ

Ingenious bathroom solutions now and in the future

sensations window & door range

POWER SHOWERS Models 4500M 5002M 4500T 5002T

at in Bathroom radiators are where fashion and function come together

Cubicle systems. Sandwich elements with coated steel or aluminium sheet. Type PUP30 / PU-ES30 / PUP40

Planning+technology ShowerCulture

LO-LINE RC & LO-LINE RC HEATER/COOLER FAN CONVECTOR MODELS: 6-4, 9-6, 14-10,

Dream DCV. Thermostatic Dual control mixer valve range. Installation guide

Installation Instructions and User Guide. Thermostatic Recessed Dual Control Shower Valve with Integral Diverter

CR5-9 A-FGJ-A-E-HQQE 1x220/240 50HZ

Transcription:

Technical datasheet

Key benefits Kundenedfald Grøn energi Minimalistic Scandinavian design A Hudevad trademark 2 steel front High quality Swedish steel makes it durable and highly resistant to impact The original flat front radiator Water-filled flat front panel and convector tubes Customisable shape and size Single, double, curved, or angled - you choose 2

Index Description... 4 Illustrations... 5 Dimensions... 5 Height and length...5 Tapping distances...6 Build-in dimensions... 7 Position of rails...8 Built-in valves...8 UR Flex... 10 Output... 15 Options... 17 Angled and curved... 17 Horizon infill panel... 18 Accessories... 19 Brackets... 19 Adjustable PR feet... 19 FDC feet... 21 Console feet... 21 Tappings... 22 3

Description Hudevad Plan is the quintessence of clean, Scandinavian design. The radiator is of the highest quality, all the while having impressive effect, poise and clarity. The simple design ensures that the Hudevad Plan radiator can fit in anywhere, and be an asset to any creative design endeavour an architect might have. Material Front plate: 2.00 steel to N 10051 Rear plate: 1.25 steel to N 10130 Plan convector tubes: 1. steel to DIN 239 Test pressure 10 bar Max. operating pressure 7.7 bar in accordance with N 442 Max. operating temperature 95 C Surface treatment Length Height Depth Pretreatment: Degreasing and passivation Priming: Primed with water based paint in pale grey Surface treatment in accordance with DIN 55900 and N 442 Plan single and double: 400-3800, in increments of 33.33 Plan single and double: 300, 400, 0, 600, 700 and 1000 Plan single: 40, 60 and 80 Plan double: 126 and 166 Tappings 1/2 standard, adapter for 3/4 Installation Optional extras Wall or floor mounted Brackets are included Air vents and plugs are included Console feet FH FDC feet, steel PR feet Adjustable brackets Colour Powder-coated white RAL 9010, gloss 70 Option: Painted in other standard RAL and BS colours 4

Illustration Hudevad Plan Plan single cutaway - rear view Plan double cutaway - rear view Dimensions Height and length 1000 700 600 0 400 300 400-3800 Plan single, Plan double, 40/60/80 126/166 Weight max. 2 kg for Plan double 5

Tapping distances Note: Always connect flow to the outermost tapping. Where Plan radiator lengths exceed 1200, and same-end tappings are required (AB, CD, 2 or 2F), Plan double is manufactured with an internal flow diverter, and Plan single is factory-fitted with a rear return tube to ensure optimum water flow. Forced water circulation does not change the standard tapping designations. Side tappings ABCD Plan single and double, front view H N Bottom tappings F/F A B Plan single and double, front view C D N H Plan single, D Plan single, Plan double, D Plan double, F P Centre distance P is calculated as: Radiator length L-100 L D D Radiator Centre height H, distance N, 300 200 400 300 0 400 600 0 700 600 1000 900 Depth, D, 40 24/44 60 41/61 80 51/71 12 6 41/61 166 51/71 6

Bottom tappings /FF Plan single, Plan double, 2 FF 2F D D Build-in dimensions Plan single, Plan double, F B A 143 113 90 C D 143 F B 113 90 A C D A = From upper edge of radiator to upper edge of bracket B = From upper edge of radiator to upper edge of screw hole F = From upper edge of radiator to lower edge of screw hole Depth, C, D, *, 40 /70 24/44 10/30 60 70/90 41/61 10/30 80 90/110 51/71 10/30 126 136/156 41/61 10/30 166 176/196 51/71 10/30 *Optional wall distance: 10 or 30 to rear of radiator UR-flex: Wall distance 30 7

Position of rails L B A B 100 A Rear view 100 If the no. of brackets is 3 or more and the no. of sections is uneven, the rail in the middle is displaced 17 towards tapping A. Note: B = 2 at flow/return side on radiators with and FF tappings. Position of rails and no. of brackets Radiator length L, No. of sections No. of brackets/spacers/rails 400-567 12-20 2/2/1 - - 600-1667 21-2/2/2 L-366 183 1700-2467 51-74 3/3/3 (L-366)/2 183 20-3800 75-114 4/4/4 (L-366)/3 183 Note: Also applies to all adjustable brackets. A, B, Built-in valves Application Tappings Dimensions Built-in valve For use where a thermostatic valve is to be integrated within the radiator, where discreet pipework is required or for the ease of installation. Type 1 valve radiator has no water panel in the first 100 of the valve side. The thermostatic sensor of the valve is passed through a hole in the front of the radiator (type 1) or through the end of the radiator (type 3). Type 1 and 3 valve radiators have underside 1/2 tappings. Tapping combinations /FF or F/F can be ordered. Air vent opposite the valve can be ordered. UR-flex tappings are available for concealed pipework. Minimum radiator length for built-in valve is 15 sections. In terms of heat output, integrated valves take up 2 sections. Type 1 valves are supplied with spindle extenders for depths 126 and 166. Type 3 valves are supplied with spindle extenders for all depths (40, 80, 126 and 166 ). Note: Spindle extender to be dismounted for presetting. Plan single with built-in valve type 1 (front) and type 3 (side) 8

Built-in valve type 1 Tappings /FF Tappings F/F Built-in valve type 1, C2 C2 C C 2 F 67 P Centre distance P is calculated as: Radiator length L-100 D D Built-in valve type 3 Tappings /FF Tappings F/F Built-in valve type 3, C C 2 F P Centre distance P is calculated as: Radiator length L-100 D D Depth, C, C2, 40 70 146 44 30 60 90 166 61 30 80 110 186 71 30 126 156 232 61 30 166 196 272 71 30 D,, 9

UR-flex Description Advice, etc. Plan with UR-flex embraces a simple, timeless design through a unique connection method that conceals all pipework. The radiators can be supplied for opposite end or same-end connections. Flexhoses made of high density armored medical silicone are included from factory. xtremely easy to clean due to the flat front, convector tubes and concealed pipework. The tappings and the UR-flex hoses are concealed behind the extended front plate. Only the air vent and the built-in valve are visible on the front. UR-flex is not available with rear return tube. If same-end connections are required, the max. radiator length is 1200. Radiators with lengths >1200 can only be supplied with diagonal tappings F/F. Available for Plan (depths 40-60-80-126-166) Wall distance Installation 30 The UR-flex hoses (provided by Hudevad) are installed between the concealed radiator tappings and the wall outlets/ PX sockets fitted by the SHAP installer. The radiator can then be mounted using the usual wall brackets. The UR-flex radiator types are also available without valves, to facilitate central valve location in an installations room, etc. Plan with UR-flex, built-in valve format 1, profile Plan with UR-flex, built-in valve format 3, profile 30 30 Plan with UR-flex, no valve, profile Plan with UR-flex, built-in valve format 4, profile 30 30 10

Built-in valve type 1 Model references and dimensional sketches for wall outlet/px socket location. 30 40 30 40 175 200 80 35 UR 1 175 200 UR 2 1 175 40 30 Built-in valve type 1, left, same end tappings, prepared for pipework. If same end tappings are required, the max. radiator length is 1200. Built-in valve type 1, left, diagonal tappings, prepared for F pipework. 40 30 UR 4 1 175 1 175 40 30 UR 3 175 200 35 200 175 80 1 175 30 40 Built-in valve type 1, right, same-end tappings, prepared for FF pipework. Built-in valve type 1, right, diagonal tappings, prepared for F pipework. If same-end tappings are required, the max. radiator length is 1200. 11

Built-in valve type 3 Model references and dimensional sketches for wall outlet/px socket location. 40 60 60 40 Built-in valve type 3, left, same-end tappings, prepared for pipework. If same-end tappings are required, the max. radiator length is 1200. Built-in valve type 3, left, diagonal tappings, prepared for F pipework. 60 40 40 60 UR 7 35 30 UR 8 1 140 200 140 1 190 200 140 30 35 UR 5 UR 6 1 190 1 190 200 140 40 30 200 140 30 40 Built-in valve type 3, right, same-end tappings,prepared for FF pipework. Built-in valve type 3, right, diagonal tappings, prepared for F pipework. If same-end tappings are required, the max. radiator length is 1200. 12

No valve Model references and dimensional sketches for wall outlet/px socket location. 30 40 30 1 60 200 60 35 60 UR 9 175 200 UR 10 175 1 30 No valve, same-end tappings, prepared for pipework. If same-end tappings are required, the max. radiator length is 1200. No valve, diagonal tappings, prepared for F pipework. 40 30 30 UR 11 1 60 200 60 35 60 1 175 UR 12 175 200 No valve, same-end tappings, prepared for FF pipework. If same-end tappings are required, he max. radiator length is 1200. 30 No valve, diagonal tappings, prepared for F pipework. 13

Built-in valve type 4 Model references and dimensional sketches for wall outlet/px socket location. 40 30 30 40 200 35 12 0 235 UR 13 200 235 UR 14 300 1 Built-in valve type 4, left, same-end tappings, prepared for pipework. If same-end tappings are required, the max. radiator length is 1200. UR 15 200 235 40 35 1 40 30 Built-in valve type 4, left, diagonal tappings, prepared for F pipework. 30 30 12 0 UR 16 235 175 40 300 1 1 200 175 40 30 Built-in valve type 4, same-end tappings, prepared for FF pipework. Built-in valve type 4, right, diagonal tappings, prepared for F pipework. If same-end tappings are required, the max. radiator length is 1200. 14

Output Plan single Depth, 40 Height, 75 /65 /20 Output Water content Weight 55 /45 /20 90 /70 /20 litres/ metre kg/ metre 300 387 209 481 1.9 16.6 400 526 278 661 2.6 21.8 0 665 342 843 3.4 26.7 600 805 410 1024 4.1 31.5 700 944 476 1205 4.7 36.2 1000 1253 628 1602 7. 0 51.5 Depth, 60 Height, 75 /65 /20 Output Water content Weight 55 /45 /20 90 /70 /20 litres/ metre kg/ metre 300 466 253 580 2.7 20.5 400 633 333 797 3.7 27. 0 0 802 408 1020 4.9 33.2 600 969 489 1237 5.9 39.3 700 1137 571 1455 7. 0 45.3 1000 1510 746 1941 10.4 64.5 Depth, 80 Height, 75 /65 /20 Output Water content Weight 55 /45 /20 90 /70 /20 litres/ metre kg/ metre 300 511 266 645 3.5 24.4 400 695 356 882 4.9 32.2 0 879 437 112 9 6.4 39.7 600 10 64 528 1366 7. 8 4 7.1 700 124 7 616 1604 9.3 54.4 1000 1655 818 212 9 13. 7 77. 5 15

Plan double Depth, 126 Height, 75 /65 /20 Output Water content Weight 55 /45 /20 90 /70 /20 litres/ metre kg/ metre 300 782 415 981 5.4 41.0 400 10 64 559 1339 7. 5 54.0 0 1345 721 1681 9.8 66.5 600 1628 842 2060 11.9 78.6 700 1909 953 2447 14.0 90.6 1000 2535 1265 3248 20.7 129.0 Depth, 166 Height, 75 /65 /20 Output Water content Weight 55 /45 /20 90 /70 /20 litres/ metre kg/ metre 300 858 474 10 60 7. 0 48.8 400 116 7 645 1442 9.8 64.4 0 1476 812 1827 12.8 79.5 600 1785 957 2230 15. 7 94.1 700 2095 1101 2636 18.5 108.8 1000 2781 1417 3537 27. 4 155.0 16

Hudevad Plan Options Angled and curved radiators Description Output calculation Installation All Plan single radiators can be supplied angled or curved. Tapping designations etc. follow the same principles as for straight radiators. Same as Hudevad Plan, depth 40 (advisory calculation). Wall or floor mounted. xternal angle Internal angle L1 L1 V L2 V L2 2 internal angles L2 L3 V1 V2 L1 xternal curve Internal curve B R B R 17

Horizon infill and end panels Application Design Lengths Height Depth Used to connect several radiators installed in a line or as a duy next to a radiator. Creates a continuous appearance where several radiators are connected. May also be used to cover pipework and electrical installations. Wall mounted. Can be dismounted for access to installations behind. Available as infill panels for installation between 2 radiators, as end panels for installation between radiator and wall, or to finish a string of radiators. Moreover, end panels can be ordered with closed ends if used to finish a string of free, wall mounted radiators. Smooth rebated front plate with closed top. With folded edge to conceal gap between radiator and Horizon infill or end panel. Mounted on wall brackets. Brackets with screws and dowels are included. Horizon infill panels: 200-20 in increments of 1 Horizon end panels: 200-20 in increments of 1 Same as radiator. Same as radiator. Optional extras Horizon end panels (can be ordered with closed ends to finish a string of free, wall mounted radiators), hole for valve, hole for socket, tamper-proof fixing, angled infill and end panels. Horizon system, front view nd panel Left Radiator Infill panel Radiator nd panel Right Horizon system, top view Wall mounting - Horizon infill and end panels Min. distance above radiator. Wall mounting - Horizon infill and end panels with brackets and spacers, with tamper-proof fixing. Min. distance above radiator. 25 Min. 133 75 Min. 18

Horizon infill panel with tamper-proof fixing Closed ends, profile Accessories Brackets 35 *Bracket BP10/30 9 Adjustable spacer for bracket 35 Adjustable brackets 76 30 23 57 Adjustable console feet PR PR feet, low - for Plan single and double PR feet, high - for Plan single and double P = 105-1 P = 180-320 114 80 Hole dimensions: 20.5 x 35.4 90 10 L x W: 124 x 103 L x W: 70 x 19

PR feet positions and dimensions M M Plan single with PR feet Plan double with PR feet K K 3 P 3 P Distance K, M and P for foot plate Depth, K, M, P (low/high), 40 42 14 105-1 or 180-320 60 42 31 105-1 or 180-320 80 42 41 105-1 or 180-320 126 10 31 105-1 or 180-320 166 0 41 105-1 or 180-320 Radiator with 2 feet, front view Radiator with 3 feet, front view A A P P B A B B A A B L L * If the no. of feet is 3 and the no. of sections in uneven, the foot in the middle is displaced 17 towards tapping A. Position and no. of feet, standard L, No. of sections No. of feet A, B, 400-1800 12-54 2 L-266 133 1833-20 55-75 3 L-266/2 133 2533-3800 76-114 4 L-266/3 133 Position and no. of feet, /FF L, No. of sections No. of feet A, B, 400-1800 12-54 2 L-400 200 1833-20 55-75 3 L-400/2 200 2533-3800 76-114 4 L-400/3 200 Note: Hudevad advises not to use feet for heights > 700, measured from upper floor surface to upper edge of radiator, unless the radiator is additionally secured at the top. 20

FDC feet, steel Height 100 (optional extra for depths 80, 126 and 166) Console feet FH Optional extra for all depts and heights 21

Tappings Hudevad Plan 001 001 002 003 005 007 008 0 052 051 053 070 072 071 073 UR 9 UR 10 UR 11 UR 12 UR1 UR 2 UR 3 UR 4 UR 5 UR 6 UR 7 UR 8 UR 13 UR 14 UR 15 UR 16 22