HEALTH & SAFETY ARRANGEMENTS FOR PORTABLE APPLIANCE INSPECTION & TESTING

Similar documents
THE SAFE USE OF ELECTRICITY

Management Standard: Portable Appliance Testing

Electrical Safety Policy and Management System

Risk Management Services. Electrical Safety Inspection and Testing. We can show you more.

Periodic Electrical Testing Policy

PERIODIC ELECTRICAL TESTING POLICY

Testing and Calibration Report

H&S Forum. Fire Safety Policy Glascote Academy

Electrical Safety Policy

HEALTH & SAFETY MANAGEMENT ARRANGEMENTS FOR FIRE SAFETY

Comment / Changes / Approval 0.1 Nov Draft Draft Policy

Electrical Management

Fire Safety Register

The Gas Safety (Installations and Use) Regulations 1998.

EMLC Academy Trust. Fire Safety Policy 2017/19. Every child deserves to be the best they can be

Fire Safety Policy Date: 0

Guide to Membership Assessments

ISLE OF WIGHT FIRE & RESCUE SERVICE

HEALTH & SAFETY POLICY. Saint Gabriel s Parish House Glasgow Terrace Churchill Gardens Pimlico Westminster London SW1V 3AA

To seek Cabinet approval of the Council s Fire Safety Policy. It is proposed that Cabinet approves the Fire Safety Policy.

Description of the property and water systems:

FIRE SAFETY FOR PRE-SCHOOLS AND CHILDCARE FACILITIES GENERAL GUIDANCE COUNTY COMMITTEE LIMERICK CHILDCARE

NOT PROTECTIVELY MARKED. Fire Legislation

Well managed building mean risk is normal. Fire action notices should be displayed by all alarm break glass call points.

Statutory Compliance Checklist

Joint Responsibility for Health and Safety Internal Guidance for Members and other occupiers of the Scottish Parliament Campus.

Property Health and Safety Compliance at Housing and Education Centres

REGULATORY REFORM (FIRE SAFETY) ORDER 2005 FIRE EMERGENCY PLAN

Qualification Specification Highfield Level 1 Award in the Principles of Fire Safety Awareness (RQF)

Fire Safety Policy. Billy Hanafin H & S and Operations Officer. Fife Cultural Trust. Version 1.0 October 2013 Page 1

1970s building housing main school reception and support offices. Well managed buildings with no significant risk of a fire occurring.

FIRE SAFETY LOG BOOK. (Record of Fire Safety Equipment Testing)

Walker Children s Club Health and Safety Policy

FIRE SAFETY POLICY & EMERGENCY EVACUATION POLICY

Fire safety procedure

Protocol between Local Housing Authorities and Fire and Rescue Authorities to improve fire safety

Fire Risk Management Policy. UK September 2017

Health & Safety Policy

Allfire Site No. a division of Allsaved Ltd. Fire Safety Log Book. Premises Address: Responsible Person:

Allianz Engineering Inspection Services Ltd. Electrical Services. Product Information

Fire Safety Management

NOTTINGHAM CITY HOMES

Index. Premises Information 2 About This Log Book 3 Service and Maintenance Requirements 4 8. Fire Risk Assessments 9

Your specialist partner for total electrical compliance. Electrical Testing

WILTSHIRE POLICE FORCE PROCEDURE. Fire Safety Management

Fire Policy. Fire Safety Order (2005) Dangerous Substances and Explosive Atmospheres Regulations (2002)

Fire Safety Policy 2018/19

Fire Safety Protocol

Electrical tests and gas safety checks for church buildings (June 2016) A Church Growth Trust Briefing Paper. Droveway ARCHITECTURE

Fire Safety Audit: Part B - Questionnaire (Questionnaire Devised By Mr.R.R.Nair) Yes No x

Fire Safety Procedures and Associated Training

LA AUDIT ASSISTANCE SURVEY: Pre-survey checklist

MANOR INFANT SCHOOL & NURSERY

Electrical Safety Requirements

Fire Risk Assessment 2017

F I R E S A F E T Y R E G I S T E R

Understanding and implementing an electrical safety regime in your organisation. Dispelling the myths and promoting a risk-based approach

Electrical Safety Policy

Electrical Safety Program

FIRE SAFETY POLICY Revised March 2013

Title: Room-sealed fanned draught flue systems concealed within voids

Fire Safety Personal Emergency Evacuation Plans Safety Guidance Note

PREMISES FIRE SAFETY LOGBOOK

June 2017 (Updated 18 January 2018) Fire Safety Policy. Peter Webb, Project Manager Compliance First Choice Homes Oldham Limited

FIRE SAFETY POLICY LEEDS METHODIST MISSION. Oxford Place Centre

S12 Fire Safety Risk Assessment H&SFS01-1 / 9

Health, Safety and Wellbeing Management Arrangements. Core I Consider I Complex. Fire Safety. Health, Safety and Wellbeing Service

Checking electrical equipment conformity with standards. M. Mostafa

STATEMENT OF THE HEALTH AND SAFETY STRATEGY FOR THE SYDNEY RUSSELL SCHOOL

Fire Evacuation Policy

Electrical Safety Policy

Note: Please send the original Policy with both signatures on it to the Norfolk CPU for the audit trail.

Fire Risk Assessment

FIRE SAFETY LOG BOOK

Australian/New Zealand Standard

Kings Fire Safety Policy

Fire Risk Assessment Safety Checklist

Millfield Schools Fire Risk Prevention Policy

Glenmere Primary School Fire Safety Policy FIRE SAFETY POLICY. Revised on April Sam Conlon. Created by S.Conlon 1

TESTSAFE. minipat APPLIANCE TESTER USER MANUAL

The Facilities Manager s Guide to: Electrical Testing, Fire Alarms and Emergency Lighting Regulations. Updated May 2016

POLICY FOR THE SAFE WORKING WITH ELECTRICITY

Contents. Ultrawave baths are manufactured in the UK and conform to exacting international standards.

Guidance Document: CCTV Policy

Fire Risk Assessment

Replacing a consumer unit in domestic premises where lighting circuits have no protective conductor

FIRE POLICY CONTENTS. Version 1.3

Fire risk management plan. MH/05/Revised/06/17

Health & Safety Policy HSP 03 Fire Safety Version Status Date Title of Reviewer Purpose/Outcome

REGULATORY REFORM (FIRE SAFETY) ORDER 2005 FIRE EMERGENCY PLAN

Model 1174 Electric Heater User instructions for LED effect 2kw Inset Heater

CERAMIC HEATER MODEL NO: DEVIL 350B 230V/110V OPERATING & MAINTENANCE INSTRUCTIONS PART NO: & ORIGINAL INSTRUCTIONS GC ISS 1

24 & 30 INCH DRUM FANS

Fire Risk Assessment

A basic guide to... Fire Safety for Scout Premises

Guide to Gate Safety Legislation & the Machinery Directive

Oil Panel Heater Instructions for Use

Fire Risk Assessment. Guidance Notes. Location details. Risk Rating. Assessors. General notes

HEALTH & SAFETY POLICY

NHS Tayside. Fire Safety Policy

Transcription:

HEALTH & SAFETY ARRANGEMENTS FOR PORTABLE APPLIANCE INSPECTION & TESTING INTRODUCTION CYNNAL recognises its duty of care to provide safe plant & equipment for employees and all reasonable steps will be taken to ensure all portable electrical equipment is safe to use. These arrangements outline the roles and responsibilities of managers of staff working with portable appliances and provide guidance on fulfilling their legal obligations in line with HSE (IND(G)236 and HS(G)107. DEFINITION Portable electrical appliance is taken to be an item of equipment which is not part of a fixed installation but is, or is intended to be, connected to a fixed installation, or a generator, by means of a flexible cable and a plug and socket. It includes equipment that is either hand held or hand operated while connected to the supply, or is intended to be moved while connected to the supply, or is likely to be moved while connected to the supply. Extension leads, plugs and sockets, and cord sets which supply portable equipment are classed as portable equipment since they operate in the same environment and are subject to the same use as the equipment they serve. MANAGEMENT RESPONSIBILITIES It is the responsibility of the Health, Safety and Welfare Team to ensure; A formal test and/or inspection of each appliance is undertaken by a competent person at the appropriate frequency depending upon the category of appliance (see appendix 1) A visual inspection of portable electrical equipment is carried out as per the recommended guidance (see appendix 1 & 2) All portable electrical equipment is labelled with a date indicating the last test date, and the date after which it must not be used unless re-tested Any electrical equipment which an employee brings in to use as part of their job role is subject to the same frequency of inspection as other workplace electrical equipment All electrical equipment, which requires testing and/or inspecting, is logged in the asset register and made available on the day of testing Records of inspections/testing are maintained using the asset register Any equipment which is provided for use by staff who are involved in agile/home working is subject to the same frequency of inspection and testing of the company s in-house electrical equipment Any equipment which is deemed unsafe and needing repair or disposal is removed from use with the plug removed and labelled accordingly All electrical equipment is disposed of in accordance with The Waste Electrical and Electronic Equipment Regulations (WEEE regulations) EMPLOYEES RESPONSIBILITIES It is the responsibility of all employees to ensure;

They take reasonable care for the health & safety of themselves and other persons who may be affected by the way they carry out their work They inform their manager of any defects or faults on portable electrical equipment which they have been provided for work (including agile/mobile workers) Any portable electrical equipment they bring in from home which is to be used as part of their job role is subject to the same frequency of inspection as other portable electrical equipment and must be tested prior to use (see appendix 1) Any electrical protection device provided for their safety is used in accordance with the instruction/training they receive INSPECTIONS AND TESTING OF NEW ELECTRICAL EQUIPMENT All portable electrical appliances will be tested on an annual cycle, in accordance with HSE guidelines and statutory requirements. The following types of modified appliances must NOT be used until tested : Hand tools and any associated leads Cleaning equipment and any associated leads Equipment manufactured or modified on site or at a similar establishment Due to the negligible failure rates for all other new equipment, they may be used without testing until that type of equipment is next due for testing. THE CONTRACTOR The contractor is the nominated contractor to undertake the tests, as selected by CYNNAL. Currently, this service is provided in-house, by competent staff. IDENTIFICATION OF EQUIPMENT The contractor will identify each portable electrical appliance with a unique number permanently affixed to the appliance. The individual sockets of multi-socket boards/blocks and extension leads will be individually identified. The number together with a description of the appliance will be entered into a database. LINKS TO OTHER POLICIES & ARRANGEMENTS These arrangements should be read in conjunction with : CYNNAL s Health and Safety Policy, which identifies the roles and responsibilities of all employees and managers Health & Safety Risk Assessment for testing Portable Electrical Appliances Health & Safety Management Arrangements for Home Working LINKS TO OTHER DOCUMENTS HSE document : electrical safety and you HSE document : Maintaining portable electric equipment in low-risk environments

CONTROL MEASURE / IMPLEMENTATION An annual Portable Appliance Testing scheme to be implemented, conducted by CYNNAL s internal PAT s team This provision to apply to all portable electrical equipment, in all premises occupied by CYNNAL, and in the homes of those staff working at home A full inventory of the equipment tested, location, results etc to be retained centrally on the company s fileserver Failed items to be immediately decommissioned, and the 3-pin plugs removed. Staff to be made aware of the requirement to visually check for defects fraying of cable sheaths, kinking of cable, exposed wires, loose components etc Visual checks to be included within the Fire Marshall s bi-monthly checks

Appendix 1 RECOMMENDED FREQUENCY OF PORTABLE APPLIANCE TESTING This guidance has been produced in accordance with HSG 107. However the frequency of testing is dependant on the risk assessment. Consideration must be given to the following factors; type of equipment and whether it is handheld or not; manufacturer's recommendations; initial integrity and soundness of equipment; age of the equipment; working environment in which the equipment is used (eg wet or dusty surroundings) or the likelihood of mechanical damage; frequency of use and the duty cycle of the equipment; foreseeable abuse of the equipment; effects of any modifications or repairs to the equipment; analysis of previous records of maintenance, including both formal inspection and combined inspection and testing Type of Electrical Equipment User Visual Checks Formal Visual Checks Recommended Frequency of Testing Heavy industrial/high risk of equipment damage Daily Weekly 6 12 months Office information technology, e.g. desktop computers, photocopiers, fax machines No 1 year 1 year Earthed (Class I) equipment, e.g. electric kettles, some floor cleaners No 1 year 1 year

Type of Electrical Equipment User Visual Checks Formal Visual Checks Recommended Frequency of Testing Double insulated equipment (not hand held) e.g. Fans, table lamps, No 1 year I year Hand held double insulated e.g. floor cleaners, kitchen equipment, irons Yes 1 year 1 year Cables and plugs and extension leads Yes 1 year 1 year Appendix 2 VISUAL INSPECTION This guidance has been produced to assist employees with assessing the integrity of electrical equipment. Under no circumstances should they dismantle any electrical equipment unless they have received formal training. The type of things to look for on the equipment, the cable and the plug (after disconnecting it) are signs of: Damage e.g. cuts, abrasion (apart from light scuffing) to the cable covering Damage to the plug, e.g. the casing is cracked or the pins are bent Non standard joints including taped joints to the cable The outer covering (sheath) of the cable not being gripped where it enters the plug or the equipment. Look to see if the coloured insulation of the internal wires are showing; Damage to the outer cover of the equipment or obvious loose parts or screws; and Overheating (burn marks or staining)