WHO IS RATH COMMUNICATIONS?

Similar documents

NURSE CALL. Tone & Visual Nurse Call Systems. Area of Refuge & Elevator Landing Two-Way Communication Systems POOL PHONES

SECTION NURSE CALL SYSTEM

Pre-Installation Requirements:

TrueCom. Building Communications Systems 5115-Series , Area of Rescue Communications System. Description

Fire Alarm System Fundamentals

ERS-3600B. PERS-3600B Personal Emergency Reporting System

The Standard In Safety

HOUSING DEVICES, INC.

Control Panel. 1.0 GENERAL SCOPE OF WORK Introduction... 2

A1UL PERS. Personal Emergency Response System. For Technical Support Please Contact Your Service Provider Or Distributor

Control/Communicator

For Dealers / Integrators / Architects. IS Series. Video Intercom. Building Communication. Controlling Security.

OJD ITB No Attachment E Duress Alarm Equipment Specifications

SP40S-D. Kingfisher Company, inc. Features: Description:

Emergency Communications Tower Applications (Solar/Wireless/Surveillance)

The New Standard In Safety

Integrated Security Solutions

Specification/ Data Sheet

EC-BOS-602/616 AX Security

Tek-SAFE Area of Rescue Assistance System

Installation & Operations Manual

PERS-3600 PERSONAL EMERGENCY REPORTING SYSTEM INSTALLATION & OPERATION INSTRUCTIONS

Honeywell Control Panels FOR RESIDENTIAL AND COMMERCIAL INSTALLATIONS. Feature Charts

GE Security Sound and Communications. Product Guide. Telligence. Voice-over-IP Patient-Staff Communication System. imagination at work

Commercial and Light Industrial Fire Alarm Control Panel

All-In-One Wireless Security System V3.2 Programming Guide. Model # MG6130 / MG6160

POWER SOURCES MODEL NO. DESCRIPTION PRICE

LORAIN CIP 4890/48120 DC Power System

DIVISION 26 ELECTRICAL SECTION FIRE ALARM SYSTEM

FireSystem 2000 Commercial and Light Industrial Fire Alarm Control Panel

Communication Products

Nurse Call Systems & Emergency Call Systems. Overview of ANSI/UL 1069 and ANSI/UL 2560

Autonomous control unit

CM800 Emergency Call System

DL150 DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL

Monitoring Solutions

SECURITY ACCESS AND SURVEILLANCE SECTION VISTA 250BP ARCHITECT AND ENGINEER SPECIFICATION FOR SECURITY SYSTEM

TALKAPHONE MASTER CATALOG

WAVE SEQUENCER DELIVERS:

Integrated Security Solutions

Situational Awareness for Life & Fire Safety. October 10, 2013

SAFEPATH Mass Notification System (SPMNS)

SAFEPATH SAFEPATH. Emergency communications system

IntelliKnight 5820XL Addressable Fire Alarm Control System Sales Guide

SECTION INTRUSION DETECTION

Public Safety DAS Annunciator Panel

SECTION COMMON WORK RESULTS FOR SAFETY AND SECURITY 1.1 RELATED SECTIONS

SMART. FLEXIBLE. RELIABLE.

ELECTRONIC SOUNDER STROBE Model : AVD-C407

Rugged Telephones GAI-TRONICS. A Hubbell Company

Fall Prevention. Systems. Discount Fall Monitoring Packages Available. Featuring. New! Economy Cordless Alarm see page 2

LORAIN CSP DC Power System

Safer Smarter More Livable Buildings. TX3 Voice Entry & Access Control Solutions. [TX3] Series.

Addressable Fire Alarm Control Panel

SECURITY ACCESS AND SURVEILLANCE SECTION VISTA 250FBP ARCHITECT AND ENGINEER SPECIFICATION FOR SECURITY SYSTEM

PROTECTION CABINETS SUPERVISION CABINETS FOR AUTOMATIC EXTERNAL DEFIBRILLATORS (AEDs)

TrueAlarm Fire Alarm Systems

To activate using remote control: press [ ] key once. To activate using keyboard: on panel keyboard [ ] keys once.

NU2 Smart Power Supply (SPS) Manual

Tek-CARE NC110, NC110A Nurse Call System

NON-MONITORED EMERGENCY CALL SYSTEMS

UltraLITE Model ELU Centralized Emergency Lighting Inverter 4.2 KW- 5 KW

TALKAPHONE MASTER CATALOG

RACK MONITORING SYSTEM - RAMOS Ultra

3226 Trunk Port FXO Doorphone

SECTION ELECTRONIC PERSONAL PROTECTION SYSTEM (EPPS)

NURSE CALL SYSTEM SPECIFICATION

EMERGENCY ASSISTANCE ALARMS

AlertWave. visiplex. From a Public Address System to an Emergency Communication System... The AlertWave system advantages:

good things in small packages

TX3 Series TX3-CX-1. Installation Manual

IRIS Connect Series Quick Installation & Maintenance Guide. Version 1.1

Signature Series 418 Mhz COMMUNICATOR RECEIVER INSTALLATION AND OPERATIONS MANUAL

Variable Frequency Drive SERIES MP800 VFD

RACK MONITORING SYSTEM RAMOS Ultra

Operation Manual Fighter ProVision Software. Version: 0.0 Revision: 1

ACC-25/50ZST. Zoned System Voice with Telephone Evacuation Control Panel

T M. User Manual. MarinaGuard. Ground Fault Monitoring Panel For Marina Shore Power

User s Guide. SUB-MA7240O-0001.OG.Solution doc. Created: 6/05/03. Last Updated: 23/09/03. MA7240AO-0001 Version 1.0

Preface. Thank you for purchasing our GSM Security Alarm System ( The System )! The System will keep your home and property safe around the clock.

2. The Group F occupancy has have an a combined occupant load of 500 or more above or below the lowest level of exit discharge.

NFPA Siemens Industry, Inc. All rights reserved. usa.siemens.com/infrastructure-cities

Now Compa ble With. VL Touchscreen Alarm. Crafted Touchscreen Security System that Revolutionizes Your World. illi tl C

RDM LOCK G Series Electromagnetic Lock. Listings. Standard Features. Ordering Information:

Soft Start Series MP700 Solid State, Reduced Voltage

RANGER 8600 DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL

RAPID RESPONSE Model RCP-1 Residential Control Panel 1 or 1-1/2 Inch (DN25 or DN40), 175 psi (12,1 bar) General Description.

Intelligent addressable fire alarm control panel

Data Sheet Fire Safety & Security Products. System Overview. Initiating Circuits SXL-EX FACP 7906

Measuring Recording Online Monitoring Regulation Alarming

AlertWave Smart Wireless Solutions for Today s Campus Whether you are a large university

DENVER PUBLIC SCHOOLS DESIGN AND CONSTRUCTION STANDARDS This Standard is for guidance only. SECTION IBAS LIGHTING CONTROL

Panel XTO210/610/710 GPRS

Elderly Care Alarm System

Independent Zone Control (I.Z.C.)

Architectural and Engineering Specification for a. Flash / Flare

Print Specification. Publication. Instructions. Specific requirements. General requirements

abode Web app Functionality

Solution for the complete management of the Hospital. Shaping communication solutions beyond the obvious

Transcription:

NURSE CALL Tone & Visual Nurse Call Systems AREA OF REFUGE Area of Refuge & Elevator Landing Two-Way Communication Systems SECURITY Blue Light & Industrial Phones ELEVATOR PHONES POOL PHONES MADE IN THE USA N56W24720 N. Corporate Circle Sussex, WI 53089 Ver. 2 02/18

Area of Refuge/Elevator Landing Two-Way Communication Systems www.area-of-refuge.com Nurse Call Systems www.rathnursecall.com Pool Phones www.pool-phone.com Blue Light & Industrial Phones www.rathsecurity.com Elevator Phones www.rathmicrotech.com WHO IS RATH COMMUNICATIONS? We have been in the Emergency Communication business for over 35 years and are the largest Communication System Manufacturer in North America. We are a privately owned company located in Sussex, WI. With over 600,000 phones in the field, you can rest assured that the quality and performance of our Communication Systems lead the industry. Our commitment to your success will be found in the quality of our products and the professionalism of our staff from the first inquiry to years after installation. NEW! TABLE OF CONTENTS Nurse Call Systems...................... Area of Refuge Systems.................. Blue Light Phones....................... Elevator Phones......................... Pool Phones............................ Continuing Education.................... Page 3-6 Page 7-12 Page 13-15 Page 16-17 Page 18 Page 19

NURSE CALL RATH Communications has developed two Nurse Call Systems to fit into the current healthcare market. The SmartCare Nurse Call Sysytem is a state-of-the-art tone and visual system with many features for the long-term care environment. The CliniCare Nurse Call System is a small and simple tone and visual system designed for small clinics and medical offices. Both are UL listed and supervised for functionality. CODE REQUIREMENTS UL 1069 Edition 7 The fundamental operation of a nurse call system shall include essential/required operation whose primary function is to provide notification and/or reset/cancellation of a staff-initiated or patient-initiated call signal to alert the staff. 1) Call annunciation at a nurse s station (audible and visual) 2) Call annunciation at the dome light (visual) 3) Call placed indicator on the patient station (visual) 4) Zone annunciation (audible and visual) 5) Call reset/cancellation SYSTEM The SmartCare System uses proprietary SmartLoop TM Power Technology so every Smart Device can be wired in sequence using standard CAT5 or better cable. The RJ45 connections make connecting devices a click away. Wireless E-Call Systems available. Contact us for a quote!

NURSE CONSOLES NURSE CALL 28 ZONE NURSE CONSOLE 2900-28AP 56 ZONE NURSE CONSOLE 2900-56AP CORRIDOR LIGHTS 112 ZONE NURSE CONSOLE 2900-112AP SMART DOME LIGHT 2900-2SDL SERIES TWO GANG SMART ZONE LIGHT 2900-3SZL SERIES THREE GANG CALLING STATIONS CHECK-IN STATION 2900-1CI SERIES SINGLE GANG PULL STRING STATION 2900-1PS SERIES SINGLE GANG (WATER RESISTANT OPTION AVAILABLE) CODE BLUE STATION 2900-1CB SERIES SINGLE GANG SINGLE BEDSIDE STATION 2900-1BS SERIES SINGLE GANG DUAL BEDSIDE STATION 2900-2DBS SERIES TWO GANG PANIC STATION 2900-1PB SERIES SINGLE GANG DUTY/STAFF STATIONS CALL CORD 2900-CC6 DUTY STATION 2900-3DS SERIES THREE GANG STAFF STATION 2900-4SS SERIES FOUR GANG

NURSE CALL SYSTEM FEATURES CHECK-IN FEATURE: The RATH Check-In Feature is great for any long-term care facility. This solution uses software to monitor residents cognitive ability and health. When the system is installed there is a check-in window programmed into the software. Each active Check-In Device is recognized on the system and must check-in within that window or an alert will be sent to the staff. DATA LOGGING FEATURE: All calls that come into the system are logged in the software and saved including the call, call cancellation, date, and time. This data is important for managing staff and residents. The data can be exported for easy evaluation. SYSTEM CONTROLLERS: The brains of the SmartCare System are located in the Host Controller. Every system requires a programmed Host Controller. Programming is done through an Ethernet port and saved on a removable USB flash drive for programming backup. Systems that exceed the device maximum and/or distances require an Expansion Board. Both the Host Controller and Expansion Board should be on a UPS for surge protection and battery backup. HOST CONTROLLER 2900-HC EXPANSION BOARD 2900-EB POWER & BATTERY BACKUP: 24V POWER SUPPLY UPS UPS WITH BATTERY BACKUP 2900-PWRS2 RP7700100 RP7700100BR PAGING SYSTEM: Every SmartCare System is capable of integrating with our Pocket Paging System. The connection for paging is done through an RS232 port on the Host Controller. The 5 watt Paging Transmitter is designed to cover even the largest facilities. When a high priority level call is placed and/or cancelled, a page will go out to every Pocket Pager on the system. This feature allows for staff to be mobile while still receiving notifications. A reminder feature sends a page when a call has gone over 5 minutes in duration. A page is also sent when a call is cancelled. 2900-PP1 2900-PPS

NURSE CALL SYSTEM The CliniCare System uses standard CAT5 or better cable and connects using RJ45 connectors. Each device on the system is wired back to the 6 Zone Annunciator Panel. The system is pre-programmed so it is simply plug and play right out of the box. ANNUNCIATOR CORRIDOR LIGHT 6 ZONE ANNUNCIATOR 2900-6AP DOME LIGHT 2900-2DL SERIES TWO GANG CALLING STATIONS PULL STRING STATION 2900-1PS SERIES SINGLE GANG (WATER RESISTANT OPTION AVAILABLE) CODE BLUE STATION 2900-1CB SERIES SINGLE GANG PANIC STATION 2900-1PB SERIES SINGLE GANG SINGLE BEDSIDE STATION 2900-1BS SERIES SINGLE GANG DUAL BEDSIDE STATION 2900-2DBS SERIES TWO GANG 24V POWER SUPPLY UPS CALL CORD 2900-CC6 2900-PWRS2 RP7700100

AREA OF REFUGE CALL BOXES 1-10 SYSTEMS 2100-956SR 2100-956SRM MUSHROOM BUTTON 2100-956RR POWDER COATED METAL 2100-984LR EXTERIOR NEMA 4 FIBERGLASS 2100-956SSRC2 WITH COVER 2100-984LRC1 EXTERIOR NEMA 4 FIBERGLASS WITH COVER 2100-958SSRC2 BRUSHED STAINLESS STEEL WITH COVER 2100-958NSR BRUSHED 2100-958NMBR BRUSHED ANTIQUE BRONZE BASE STATIONS POWER SUPPLY: 2500-PWR24 2500-205D/2500-205PSS 5 ZONE SURFACE/ 2500-205B 5 ZONE CABINET WITH DOOR 2500-205FM 5 ZONE CABINET WITH DOOR 2500-210D/2500-210PSS 10 ZONE SURFACE/ 2500-210B 10 ZONE CABINET WITH DOOR 2500-210FM 10 ZONE CABINET WITH DOOR

AREA OF REFUGE 1-92 SYSTEMS CALL BOXES 2400-805SP 2400-805SPM MUSHROOM BUTTON 2400-805RP POWDER COATED METAL 2400-805LP EXTERIOR NEMA 4 FIBERGLASS 2400-805SSPC2 WITH COVER 2400-805LPC1 EXTERIOR NEMA 4 FIBERGLASS WITH COVER 2400-808SSPC2 BRUSHED STAINLESS STEEL WITH COVER 2400-808NSP BRUSHED 2400-808NMP BRUSHED ANTIQUE BRONZE COMMAND CENTERS PART # 2500-12RC(F) 2500-12NC 2500-16RC(F) 2500-16NC 2500-28RC(F) 2500-28NC 2500-36RC(F) 2500-36NC 2500-56RC(F) 2500-56NC 2500-76RC(F) 2500-76NC 2500-92RC(F) 2500-92NC DESCRIPTION 12 ZONE-, (F) 12 ZONE- DESK MOUNT 16 ZONE-, (F) 16 ZONE- DESK MOUNT 28 ZONE-, (F) 28 ZONE- DESK MOUNT 36 ZONE-, (F) 36 ZONE- DESK MOUNT 56 ZONE-, (F) 56 ZONE- DESK MOUNT 76 ZONE-, (F) 76 ZONE- DESK MOUNT 92 ZONE-, (F) 92 ZONE- DESK MOUNT SURFACE/ DISTRIBUTION MODULE DESK MOUNT POWER SUPPLY: RP7700104 OR RP7701500 NOTE: DISTRIBUTION MODULE IS INCLUDED WITH BASE STATION.

AREA OF REFUGE CALL BOXES IP SYSTEMS 2100-956SIP 2100-984RIP EXTERIOR NEMA 4 FIBERGLASS 2100-956SIPC2 WITH COVER 2100-958SIPC2 BRUSHED STAINLESS STEEL WITH COVER 2100-958NSIP BRUSHED 2100-958NMBIP BRUSHED ANTIQUE BRONZE COMMAND CENTERS PART # DESCRIPTION 2500-10R_V 10 ZONE- FLUSH (CF) OR SURFACE (C) MOUNT CABINET 2500-10NCV 10 ZONE- DESK MOUNT 2500-16R_V 16 ZONE- FLUSH (CF) OR SURFACE (C) MOUNT CABINET 2500-16NCV 16 ZONE- DESK MOUNT 2500-32R_V 32 ZONE- FLUSH (CF) OR SURFACE (C) MOUNT CABINET 2500-32NCV 32 ZONE- DESK MOUNT 2500-48R_V 48 ZONE- FLUSH (CF) OR SURFACE (C) MOUNT CABINET 2500-48NCV 48 ZONE- DESK MOUNT 2500-64R_V 64 ZONE- FLUSH (CF) OR SURFACE (C) MOUNT CABINET 2500-64NCV 64 ZONE- DESK MOUNT 2500-80R_V 80 ZONE- FLUSH (CF) OR SURFACE (C) MOUNT CABINET 2500-80NCV 80 ZONE- DESK MOUNT 2500-96R_V 96 ZONE- FLUSH (CF) OR SURFACE (C) MOUNT CABINET 2500-96NCV 96 ZONE - DESK MOUNT 2500-112R_V 112 ZONE- FLUSH (CF) OR SURFACE (C) MOUNT CABINET 2500-112NCV 112 ZONE- DESK MOUNT 2500-128R_V 128 ZONE- FLUSH (CF) OR SURFACE (C) MOUNT CABINET 2500-128NCV 128 ZONE- DESK MOUNT NOTE: DISTRIBUTION MODULE IS INCLUDED WITH BASE STATION. 2100-VOIP DESK MOUNT DISTRIBUTION MODULE SURFACE/ POWER SUPPLY: RP7700104

AREA OF REFUGE ELEVATOR LANDING SIGNAGE 7049 8 H X 6 W 7041E 8 X 8 PHOTO LUMINESCENT 7087 8 X 8 7050E/7050ED 14 LED LIGHT UP WITH BATTERY BACKUP 120/277V AREA OF REFUGE 7041 8 X 8 PHOTO LUMINESCENT 7046 8 X 8 PHOTO LUMINESCENT 7043 8 X 6 7044 8 X 6 7047R 5 X 15 7047L 5 X 15 7050/7050D 14 LED LIGHT UP WITH BATTERY BACKUP 120/277V 7045 17 DIAMETER AREA OF RESCUE ASSISTANCE ALL SIGNS AVAILABLE WITH THE ACTIVE WHEELCHAIR ICON 7085 8 X 8 PHOTO LUMINESCENT 7086 11 X 5 7080 8 X 6 7090/7090D 14 LED LIGHT UP WITH BATTERY BACKUP 120/277V

AREA OF REFUGE COMMUNICATION SUPERVISION 1-10 ANALOG SYSTEMS Each 2100 Series Call Box comes with built-in communication verification software and failure relay output which can be connected to an addressable fire alarm module or the fire control panel. 1-92 ANALOG SYSTEMS 2500- SPRVSR Monitors remote Call Boxes, Base Station phone, and telephone lines Provides a relay output when it does not detect a component of the system Wall mounted swing out bracket Connections: RJ11 connections to each Call Box, Base Station phone, phone line, and punch down terminal connections to Distribution Module Power: 12vdc (includes UL listed transformer that plugs into a 120vac backed up source, or use RATH model RP7700104 or RP7701500)

AREA OF REFUGE 2500-VOIPM IP SYSTEMS Power: 120vac from a backed up power source or RATH RP7700104 Current draw: 270mA Output: (2) Form 1C SPDT switches, (1) NO and (1) NC Rated 277vac at 20A Ethernet: (2) 10 Base-T or 100 Base-T, 8-pin RJ45 connection Network: Ethernet IPv4 Requires static IP addresses for all components Supports web browser: HTTP/HTTPS, XML, Modbus/TCP & SNMP protocols LED indicators: green (power on), yellow (network) Temperature range: -40F +150F Non-volatile memory Electromagnetic compliance: IEC CISPR 22, 24 FCC 47CFR15 (Class B) UL 61010-1 Wall mount enclosure with door POWER SUPERVISION 2500-UPSMONITOR Comes with Power Failure Relay Output Power Supervision requires additional purchase of: UPS Backup RP7700104 or RP7701500 2 HOUR FIRE-RATED CABLE PART # DESCRIPTION CABLE RP6600100M CI 2 HOUR FIRE-RATED 2 PAIR COMM CABLE (100 METER) RP6600300M CI 2 HOUR FIRE-RATED 2 PAIR COMM CABLE (300 METER) RP66010001 UL LISTED CI 2 HOUR FIRE-RATED SINGLE PAIR COMM CABLE (500 FEET) RP66010002 UL LISTED CI 2 HOUR FIRE-RATED SINGLE PAIR COMM CABLE (1,000 FEET) RP6600100M4 CI 2 HOUR FIRE-RATED 4 PAIR COMM CABLE (100 METER) (IP SYSTEMS ONLY) RP6600300M4 CI 2 HOUR FIRE-RATED 4 PAIR COMM CABLE (300 METER) (IP SYSTEMS ONLY) COMMUNICATION & POWER CABLE PART # DESCRIPTION RP7500094 22 AWG SHIELDED 2 PAIR COMM CABLE (1,000 FEET) RP7500094P 18-2 SOLID SHIELDED POWER CABLE (1,000 FEET) (1-10 ANALOG SYSTEMS ONLY)

BLUE LIGHT PHONES 9 WIRED TOWERS (2100-TP SERIES) STANDARD FEATURES: Calls up to 5 phone numbers Blue beacon/strobe with photocell Recessed illuminated face plate Call assurance LED Blue strobe 11 gauge steel ADA compliant OPTIONAL FEATURES: Dome Camera Discrete View TM Camera Siren Mass Notification Speaker Housing Custom colors and lettering Amber or red strobe Wide Area Light Dual button face plate Face plate cover COLOR OPTIONS: WHITE (STANDARD) RED LETTER POSTAL BLUE SAFETY YELLOW ARCHITECTURAL BRONZE EQUIPMENT BLUE CAMPUS GREEN WHITE WITH BLUE TEXT (STANDARD) 9 SOLAR TOWERS (2100-TS SERIES) HEIGHT WITH SOLAR PANEL: 12 STANDARD FEATURES: Calls up to 5 phone numbers Blue beacon/strobe with photocell Recessed illuminated face plate Call assurance LED Blue strobe 11 gauge steel ADA compliant OPTIONAL FEATURES: Dome Camera Discrete View TM Camera Siren Custom colors and lettering Amber or red strobe Service indicator Dual button face plate Face plate cover COLOR OPTIONS: WHITE (STANDARD) RED LETTER POSTAL BLUE SAFETY YELLOW ARCHITECTURAL BRONZE EQUIPMENT BLUE CAMPUS GREEN WHITE WITH BLUE TEXT (STANDARD) 5 8 PEDESTALS (2100-PP SERIES) STANDARD FEATURES: Calls up to 5 phone numbers Blue beacon/strobe Recessed illuminated face plate Call assurance LED Blue strobe 11 gauge steel ADA compliant OPTIONAL FEATURES: Discrete View TM Camera Custom colors and lettering Amber or red strobe Dual button face plate Face plate cover COLOR OPTIONS: WHITE (STANDARD) RED LETTER POSTAL BLUE SAFETY YELLOW ARCHITECTURAL BRONZE EQUIPMENT BLUE CAMPUS GREEN WHITE WITH BLUE TEXT (STANDARD)

36 WIRED CALL STATIONS (2100-CP SERIES) BLUE LIGHT PHONES STANDARD FEATURES: Calls up to 5 phone numbers Recessed illuminated face plate Call assurance LED Blue strobe Aluminum enclosure ADA compliant OPTIONAL FEATURES: COLOR OPTIONS: Discrete View TM Camera WHITE (STANDARD) Siren RED LETTER Mass Notification Speaker Housing POSTAL BLUE Custom colors and lettering SAFETY YELLOW Stainless Steel enclosure Amber or red strobe EQUIPMENT BLUE Pole mount bracket CAMPUS GREEN Dual button face plate Face plate cover ARCHITECTURAL BRONZE WHITE WITH BLUE TEXT (STANDARD) 36 SOLAR CALL STATIONS (2100-CS SERIES) STANDARD FEATURES: Calls up to 5 phone numbers Recessed illuminated face plate Call assurance LED Blue strobe Aluminum enclosure ADA compliant OPTIONAL FEATURES: Discrete View TM Camera Siren Mass Notification speaker housing Custom colors and lettering Stainless Steel enclosure Amber or red strobe Pole mount bracket Dual button face plate Face plate cover COLOR OPTIONS: WHITE (STANDARD) RED LETTER POSTAL BLUE SAFETY YELLOW ARCHITECTURAL BRONZE EQUIPMENT BLUE CAMPUS GREEN WHITE WITH BLUE TEXT (STANDARD) 30 ECO LIGHT WEIGHT CALL STATIONS (2100-E SERIES) STANDARD FEATURES: Calls up to 5 phone numbers Call assurance LED Blue strobe Aluminum enclosure ADA compliant OPTIONAL FEATURES: Custom colors and lettering Stainless Steel enclosure Amber or red strobe Pole mount bracket Dual button face plate Face plate cover COLOR OPTIONS: WHITE (STANDARD) RED LETTER EQUIPMENT BLUE WHITE WITH BLUE TEXT (STANDARD)

BLUE LIGHT PHONES POWER OPTIONS 120VAC OR 12VDC SOLAR DUSK2DAWN (SEE BELOW) COMMUNICATION OPTIONS Ask About our 4G Solution! LANDLINE CELLULAR 2-WAY RADIO VOIP WI-FI VOIP 900MHZ DUSK2DAWN TECHNOLOGY RATH Dusk2Dawn Technology feature allows for the utilization of intermittent power that is controlled by a timer or photocell. The technology can run on battery power while the AC power is absent and recharge when power is available.

SMARTPHONES BEHIND THE PANEL (CONTACT US FOR DIRECT MOUNT COMPETITOR PLATES) ELEVATOR PHONES 2100-957CC 2100-957RA 2100-907RA 2100-956SS 2100-956RS POWDER COATED METAL 2100-984LF NEMA 4 FIBERGLASS EXTERIOR 2100-956BL HEAVY DUTY ABS 2100-956SSC2 (WITH COVER) 2100-958NSS BRUSHED ACCESSORIES 2100-958DO BRUSHED 2100-958SS BRUSHED 2100-958MB BRUSHED ANTIQUE BRONZE 2100-958NMB BRUSHED ANTIQUE BRONZE 2100-958SSC2 BRUSHED (WITH COVER) IP INTERFACES ELEVATOR PHONE INTERCOMS (LOBBY & MACHINE ROOM UNITS) 2100-VOIP CELLULAR INTERFACES 2100-VOIPLC UPS RP7700100 GSM UNIT 2100-GSMLC CDMA UNIT 2100-CDMALC

ELEVATOR PHONES LINE POWERED PHONES BEHIND THE PANEL (CONTACT US FOR DIRECT MOUNT COMPETITOR PLATES) 2400-807RAS 2400-807CC 2400-807RA 2400-805SS 2400-805RS POWDER COATED METAL 2400-805LF NEMA 4 FIBERGLASS EXTERIOR 2400-805RD HEAVY DUTY ABS 2400-805SSC2 WITH COVER 2400-808NSS BRUSHED STAINLESS STEEL 2400-808DO BRUSHED STAINLESS STEEL 2400-808SS BRUSHED STAINLESS STEEL 2400-808MB BRUSHED ANTIQUE BRONZE 2400-808NMB BRUSHED ANTIQUE BRONZE 2400-805SSC2 BRUSHED WITH COVER

POOL PHONES 610POOL_ INTERIOR HANDSET 646POOL_ INTERIOR HANDSET 674POOL_ INTERIOR HANDSET 675POOL_ INTERIOR HANDSET (MANUAL DIAL) 624POOL_ HANDSET WITH ENCLOSURE 624MPOOL_ HANDSET WITH ENCLOSURE (MANUAL DIAL) 970POOL_ SPEAKERPHONE WITH ENCLOSURE 2400-886DA_ SPEAKERPHONE 2100-986WIFIV SPEAKERPHONE 690RDPOOL_ HANDSET WITH ENCLOSURE 990RDPOOL_ SPEAKERPHONE WITH ENCLOSURE 690SYPOOL_ HANDSET WITH ENCLOSURE 990SYPOOL_ SPEAKERPHONE WITH ENCLOSURE 624POOLVOIP_ HANDSET WITH ENCLOSURE 624MPOOLVOIP_ HANDSET WITH ENCLOSURE (MANUAL DIAL) 970VOIP_ SPEAKERPHONE WITH ENCLOSURE 984POOL_ SPEAKERPHONE 984POOLC1_ SPEAKERPHONE WITH COVER

CONTINUING EDUCATION LUNCH & LEARN AIA CERTIFIED LUNCH & LEARNS RATH Lunch & Learn programs are 50 minute presentations with an additional 10 minutes of questions and discussion. THE COURSES COVER: Scope and Design Communication and Signage Requirements IBC, NFPA, and ADA Code Requirements Location: Course can be completed at your office or via webinar as part of our distance learning program Lunch: Free catered lunch provided for all attendees Continuing Education Units: 1 AIA CEU in HSW TECHNICAL TRAINING WEBINARS How to properly wire, set-up, and install RATH SmartRescue and Command Center Communication Systems. Available options and best practices for specifying, installing, and implementing RATH IP Communication Systems. We will ship a kit to you and schedule a one-on-one webinar or Q&A session. Upon completion, ship the kit back at our expense.

THE CODE EXPERTS INTERNATIONAL BUILDING CODE (IBC) IBC 2009 & 2012 1009.8 Two-Way Communication. A two-way communication system complying with Sections 1009.8.1 and 1009.8.2 shall be provided at the landing serving each elevator or bank of elevators on each accessible floor that is one or more stories above or below the level of exit discharge. Exceptions: 1. Two-way communication systems are not required at the landing serving each elevator or bank of elevators where the two-way communication system is provided within Areas of Refuge in accordance with Section 1009.6.5. 1009.8.2 Directions. Directions (Part #7049) for the use of the two-way communication system, instructions for summoning assistance via the two-way communication system and written identification of the location shall be posted adjacent to the two-way communication system. Signage shall comply with the ICC A 117.1 requirements for visual characters. 1009.9 Signage. Signage indicating special accessibility provisions shall be provided as shown: Each door providing access to an Area of Refuge an adjacent floor area shall be identified by a sign stating: AREA OF REFUGE. (Part #7043/7044) Each door providing access to an exterior area for assisted rescue shall be identified by a sign stating: EXTERIOR AREA FOR ASSISTED RESCUE. (Part #7086) Where exit sign illumination is required by Section 1013.3, the signs shall be illuminated. (Part #7050) Additionally, visual characters, raised character and braille signage complying with ICC A 117.1 shall be located at each door to an Area of Refuge and exterior Area for Assisted Rescue in accordance with Section 1013.4. (Part #7043/7044) Signage shall comply with the ICC A 117.1 requirements for visual characters and include the International Symbol of Accessibility. IBC 2015 & 2018 codes can be found in the Code Requirements section of our website. AMERICANS WITH DISABILITIES ACT (ADA) REQUIRED MOUNTING HEIGHTS: NATIONAL FIRE PROTECTION ASSOCIATION (NFPA) NFPA 72-2016 SUPERVISION REQUIREMENTS: 24.10.4- All pathways between a remote area of refuge station and the central control point shall be monitored for integrity. 24.13.4 Power Supplies- All control units shall meet the power supply requirements of section 10.6s. 10.6.9 Monitoring Integrity of Power Supplies 10.6.9.1- Unless otherwise permitted or required by 10.6.9.1.3 and 10.6.9.1.6 all primary and secondary power supplies shall be monitored for the presence of voltage at the point of connection to the system. 10.6.9.1.1- Failure of either the primary or secondary power supply shall result in a trouble signal in accordance with section 10.14. 10.6.7.2.1- The secondary power supply (battery backup) shall have sufficient capacity to operate the system under quiescent load (system operating in a non-alarm condition) for a minimum of 24 hours and, at the end of that period, shall be capable of operating all alarm notification appliances used for evacuation or to direct aid to the location of an emergency for 5 minutes. CABLE REQUIREMENTS: 24.3.13.9.1- Area of Refuge emergency communications systems shall have a pathway survivability of Level 2 or Level 3. (Level 1 is permitted if where the building is less than 2-hour fire-rated construction). 12.4.3- Pathway Survivability Level 2- Shall consist of one or more of the following: (1) 2-hour fire-rated circuit integrity (CI) or fire-resistive cable. (2) 2-hour fire-rated cable system (electrical circuit protective systems). (3) 2-hour fire-rated enclosure or protected area. (4) Performance alternatives approved by the authority having jurisdiction. 12.4.4 Pathway Survivability Level 3- Shall consist of pathways in buildings that are fully protected by an automatic sprinkler system in accordance with NFPA13 and one or more of the following: (1) 2-hour fire-rated circuit integrity (CI) or fire-resistive cable. (2) 2-hour fire-rated cable system (electrical circuit protective systems). (3) 2-hour fire-rated enclosure or protected area. (4) Performance alternatives approved by the authority having jurisdiction.