Car Park Ventilation 1

Similar documents
Emergency Extract Ventilation

POWERPLUS SPP Product Brochure

SMOKE CONTROL - NEW DIRECTIONS

Colt ventilation systems for car parks, loading bays and service areas

INTRODUCTION. JAU /JCC/JVC Series Jet Fans - for car park ventilation

incorporating Contractors guide to car park ventilation A no-nonsense guide to the safe ventilation of underground and covered car parks

LOWERING THE COST OF HIGH CEILINGS

SAX. Window & Wall Fans

UNIJET CAR PARK VENTILATION SYSTEM

0.4 m 3 /s. Plastic and Steel cased fan Units. Round Fans. Latest EC Fan Technology. Compact and Powerful. Easy to install

GreenJet Transfer Fans

technical specification smoke venting systems

GORILLA HVLS Installation & Maintenance

Colt Car Park Ventilation Systems. Smoke Control

AXIAL & JET FANS FOR TUNNEL VENTILATION

The ideal cooler at a competitive price KELVION TEC COMMERCIAL AIR COOLER

SUNWARM AIR SOLAR PRE-HEAT VENTILATION SYSTEM

HIT Centrifugal In-Line Fan

Intumescent Fire Dampers

we make air move Double Inlet Centrifugal Fans (Forward Curved) FBD Series (Square Outlet Metric Size)

SAM. Small Air Handling. VES SMALL AIR HANDLERS part of a complete range of innovative, flexible products from the HVAC experts

TUNNEL FANS STANDARD AND HOT SMOKE

Tunnel Systems. Design & Supply Metro Axial Fans. Tunnel Axial Fans. Jet Fans.Fans for Escape Tunnel System Components. Engineering Support

Novenco jet fans. AUO / ARO / AUT / ART / CGF January 2010

TECHNICAL DATA. F.H. Biddle B.V. P. O. Box 15, NL-9288 ZG Kootstertille,The Netherlands. Tel: Fax:

XB-EFA-8L-BK & XB-EFA-8R-BK

Systemair product news - Fans NEWS

DALAMATIC DUST COLLECTORS

GIVE A FAN A CHANCE Installation Dos & Don ts

Optimal work climate with open doors. Industrial air curtains Model IndAC

Howorth Air Technology. Pharmaceutical Containment Solutions

Clean Air Laminar Flow Ceiling CG 3 A CLEAN AIR WORLD. Draft-free, comfortable room climate. Minimal, undisruptive noise level

JM Aerofoil Fans Bulletin JMA60-05

more than just a fan supplier more than just a fan supplier Axair Fans UK Limited

In accordance with: Period of Fire Resistance: 180 minutes (3 hours) integrity (single) 120 minutes (2 hours) integrity (overlapped)

Superior. A Compact Floor Standing Gas Fired, High Efficiency Condensing Hot Water Boiler. Outputs 120, 160, 200, 240, 280 kw

PFS Single stage axial fan The axial fan for modern boiler plants

FireClass. Introducing a new class of fire detection

Technical Information

ROLLAIR AIR COMPRESSORS

COOLflow 4E PRODUCT RANGE

Pure competence in air. NOVENCO BUILDING & INDUSTRY PRODUCT BROCHURE

Howorth Air Technology. Pharmaceutical Containment Solutions

incorporating Guidance to Shafts for Smoke Control A useful guide to practical smoke shaft principals and specifications

ELTA FANS IN-LINE MIXED FLOW FAN IMF100 / 125 / 150 / 200 INCLUDING MODELS WITH BUILT-IN-RUN-ON TIMERS T

OIL-INJECTED ROTARY SCREW COMPRESSORS. GA 7-75 VSD+ (7-75 kw/ hp)

WELD STRONG BREATHE FREE

VRV The total solution. Integrated Climate Control

Mechanical smoke ventilation systems. CI/SfB 37.4 Xy

Recessed. Air Curtain. Fig 1. Recessed air curtain

Innovation in air purification unmatched air quality

NOVENCO BUILDING & INDUSTRY PRODUCTS. Products

AIR TREATMENT. ReCOOLER HP» INTEGRATED COOLING/HEATING FUNCTION WITH REVERSIBLE HEAT PUMP IN THE eq AIR HANDLING UNIT

Flue Dilution Fans. Specialists in Air Movement Technology. IMPROVED GBDF MK5 Now includes a Pressure Safety Switch and easier Electrical Connections

Underground carpark ventilation

Centrifugal Fans, Non-Overloading, Backward Inclined

1 - Donkin Fans. Majax-2 Aerofoil Axial Flow Fans

AIR CURTAIN GUIDE WHAT IS AN AIR CURTAIN?

Enriching Environments

Trane Performance Climate Changer Air Handlers. An air handler for every need.

Natural Ventilation. e-stack A-Series Ventilation System for Buildings with Atria. Installation and Maintenance. Palletised

Building Services Brochure

Stored Water District Heating Interface Units. Heat Interface Units

AIR HANDLING UNITS ASSET REFERENCE: DESIGN AHU 1 AHU 2

Atlas Copco. Oil-injected Rotary Screw Compressors Variable Speed Drive + (7-15 kw/10-20 hp)

MRXBOX90 - WHOLE HOUSE HEAT RECOVERY UNIT

HEATING & COOLING COIL PRODUCTS

All Heaters Part L2B Compliant. Technical Data External Oil and Gas Cabinet Heaters. For Models. EVD Vertical Ducted EHD Hortizontal Ducted

Mechanical Ventilation with Heat Recovery: Designing and implementing a robust and effective ventilation system

INDUSTRIAL AIR CURTAIN. IndAC 2

AT, MT & ES Series Super Low Sound Fan

CARE GUIDANCE. Local Exhaust Ventilation (LEV) Systems for High Temperature Insulation Wool (HTIW) LEVEL 2 RECOMMENDATIONS ON BEST PRACTICE

1 Development and state of the art in road tunnel ventilation technology

Tunnel Axial Flow Fan

Coal Handling and Processing. Advanced Solutions for Coal-Related Environmental Dust Control. Better Air is Our Business

Environmentally Friendly Grease Management Solutions

CI/SfB (57.7) 1st Edition. Lo-Carbon Response/SELV dmev Unit. A new generation of Lo-Carbon continuous running fans

Sentinel Demand Energy Recovery Ventilation

S T O R E R A N G E C Y L I N D E R & G R A N T FEATURES: GRANT MONOWAVE UNVENTED DIRECT AND INDIRECT SINGLE-COIL CYLINDERS

Screw Compressors AS SERIES. Capacities from: 59 to 124 cfm Pressures from: 80 to 217 psig

Laboratory Automation & Robotic System Enclosures

Engineered efficiency - no matter where or what. KMe Coolers Fresh ideas from Searle. GEA Searle

EHH SERIES DRAW THROUGH FAN COILS CFM

MINIFLOW SMF Installation & Maintenance

Quality Products AHU Repair, Refurbishment and Replacement

Extended Range. PRESFIX Packaged Pressurisation Sets AUTOMATIC MAKE-UP UNITS FOR SEALED HEATING AND CHILLED WATER SYSTEMS.

Colt International Ltd Commissioning and maintenance of smoke control systems CPD Technical Seminar

Maximum Dimensions: Approved for spans unlimited in width, heights up to 10.5 m ( in), minimum panel overlap 400 mm (15.

Atlas Copco Stationary Air Compressors. GA30-90C WorkPlace Air System TM 30-90kW/40-125HP oil-injected rotary screw compressors

Outdoor Enclosures. Outdoor Enclosures Protected like a bunker for all harsh environments

EKF. EC kitchen extract fan range. Installation and Wiring Instructions. Stock Ref. N EKF355E1 EKF400E1 EKF450E1 EKF450E3 EKF500E3 EKF560E3

TECHNICAL SPECIFICATIONS - CW-80T-TWIN AUSTRALIAN, EUROPEAN, SOUTH AFRICAN & UK

STEEL DUCT - FIRE RATED CLADDING INSTALLATION MANUAL

Using Portable Spot Air Conditioners in Industrial Applications

MJC Mini. Cartridge Filter. Features. Principal specification and options

Best practice guide. Hardware for sliding doors and folding doors to BS EN in association with. Association of Building Hardware Manufacturers

COMPRESSORS M100 MOBILAIR. Portable Compressor With the world-renowned SIGMA PROFILE Flow rate 6.4 to 10.2 m³/min ( cfm)

JET FANS CAR PARK VENTILATION SYSTEMS F400 - F300 - F200. EN Powered smoke and heat exhaust ventilators for use in Construction Works

AP-EH500-L/RQA9837. Installation Guide

Controlled mechanical ventilation GB 03

Transcription:

Car Park Ventilation 1

Mechanically vented car parks are designed to operate with either traditional ducted or modern impulse ventilation systems. Our car park fans operate on well-proven tunnel ventilation principles, producing a high velocity jet that, as it diffuses, imparts thrust to the surrounding air through mixing and entrainment. We manufacture a range of fans including axial and centrifugal variants for both general ventilation and emergency situations in car park applications. Our JetVent range includes induction and impulse ventilation models specifically developed to operate as both general ventilation and for once-only, emergency extract mode at temperatures of up to 400 C. The product design eliminates the requirement for ducted systems, making efficient use of the limited space of enclosed car parks, in addition to reducing power consumption and the associated running costs.

PART OF ELTA GROUP Across all of our people, in all of our businesses, on all continents on which we operate, Elta Group has one purpose: To enhance life through air. For 20 years we have been a proudly independent, family-owned group, but our foundations were laid over 45 years ago. Our foundations were built on an entrepreneurial spirit and a clear vision of meeting market needs and improving air quality. These have seen us become a leader in high-integrity solutions that move, filter, treat and distribute air, from agriculture to building services to applied technology. We re never standing still, always living and breathing our cause, and looking to the horizon. eltagroup.com 4 Car Park Ventilation

Europe Africa Asia Australasia REGIONS Building Services Applied Technology Agriculture International MARKETS Fans Air Handling Heat Recovery Filtration Natural Ventilation Acoustics Air Distribution Controls Heating Cooling Welfare Lighting PRODUCTS 5

6 Car Park Ventilation

Impulse Ventilation The impulse ventilation system is based on a number of small, strategically located high velocity fans in place of the distribution ductwork traditionally used in car parks. Impulse fans operate on well-proven tunnel ventilation principles, producing a high velocity jet which thrusts against the air in front of the fan imparting momentum to all the surrounding air through entrainment as it diffuses. The volume of entrained air is significantly greater than that passing through the fan. The impulse fans are carefully positioned to direct the airflow towards the main extract fan intake points. 7

JetVent Axial Impulse Fans JetVent Axial Impulse fans have been specifically designed to provide a high velocity airflow to help overcome problems caused by obstructive structural beams and low overall ceiling heights found in car parks. The innovative design of JetVent Axial Impulse fans provides major benefits in terms of reduced installation and running costs as well as effective smoke control. Technical excellence and innovation in design are the cornerstones of an Elta Fans product - JetVent is no exception to this approach. The harmony of our engineering excellence and technical sophistication combine to provide a first class product which meets demanding smoke, as well as general fume, applications. With tomorrow s technology at our finger tips, utilising market leading software, Elta Fans can pinpoint, analyse and make design changes and improvements without the expense of conventional prototyping, working with our customers to meet their specific needs. 8 Car Park Ventilation

Conventional & Impulse Ventilation Conventional Ducted System Equivalent Impulse Layout Exhaust Point Ventilation Ducts Exhaust Point Impulse Fans The distribution ducting used in traditional systems is replaced by a number of small JetVent impulse fans to direct the airflow across the designated area. Without the distribution duct resistance, smaller exhaust and supply fans and / or motors can be used. Impulse Ventilation. Section View: Discharge angled to efficiently move air Exhaust via main exhaust fans JetVent Impulse Fan Zone of turbulent mixing Air Inlet Impulse Ventilation 9

Features & Benefits The JetVent Axial Impulse fan range is available with either unidirectional or truly reversible airflow. JetVent can run in either normal extract mode or once only smoke operation at up to 400ºC for 2 hours which means cost savings as a single fan provides both general and smoke extract requirements. Better Security The elimination or reduction in ductwork means a safer, lighter environment with better security due to the increased visibility. No Ductwork By adding momentum to the air, JetVent thrusts air towards the desired extract points to ensure stagnant fumes and smoke are cleared effectively and efficiently. This principal eliminates the requirement for ductwork within a car park, as the JetVent effectively transfers the polluted air, allowing for better use of limited space in underground facilities. Low Maintenance With no ductwork, maintenance costs are reduced as there is no ducting to become blocked, damaged or subject to leakage. Cost Effective JetVent provides the scope for reduced installation and overall construction build costs compared with traditional ducted systems. The high efficiency impellers make this a very economical method of moving high volumes of air. Design Appeal The integral bell mouth inlet has a streamlined appearance for improved performance and sound. Robust Design JetVent axial fans are of a robust, heavy duty construction for added strength and durability. Fan casings are heavy gauge, sheet steel, roll formed and welded and hot dipped galvanised after fabrication to BS EN ISO 1461. 10 Car Park Ventilation

Performance & Dimensional Data Flanged Units JetVent Unidirectional High Thrust Product Code JFU/F3-315-2-HAI JFU/F3-355-2-HAI JFU/F3-400-2-SAI JFU/F3-400-2-HAI Thrust N Volume Flow Rate m 3 /s Velocity m/s Sound Pressure dba @ 1m Speed r/min Motor Power kw FLC Amps SC Amps Absorbed Power kw High 30 1.40 17.91 65 2875 1.27 2.73 14.5 0.91 Low 10 0.81 10.34 47 1460 0.29 0.82 2.9 0.15 High 50 2.03 20.52 70 2920 2.53 5.25 31.5 1.73 Low 15 1.11 11.24 52 1475 0.58 1.68 5.4 0.23 High 50 2.29 18.21 63 2835 1.27 2.73 14.5 0.95 Low 16 1.29 10.30 47 1450 0.29 0.82 2.9 0.15 High 80 2.89 23.03 69 2895 2.53 5.25 31.5 2.30 Low 18 1.37 10.93 51 1465 0.58 1.68 5.4 0.30 Product Code Dia. A B C D E F G H J K L Weight kg JFU/F3-315 315 332 280 12 225 160 484 296 413 226 1686 442 58 JFU/F3-355 355 416 360 12 244 180 544 331 440 227 1694 444 79 JFU/F3-400 400 416 360 12 244 180 569 331 503 266 2192 520 98 4 HOLES C A B F G H J D E K L 12 Car Park Ventilation

Flanged Units JetVent Truly Reversible High Thrust Product Code JFR/F3-315-2-HAI JFR/F3-355-2-HAI JFR/F3-400-2-SAI JFR/F3-400-2-HAI Thrust N Volume Flow Rate m 3 /s Velocity m/s Sound Pressure dba @ 1m Speed r/min Motor Power kw FLC Amps SC Amps Absorbed Power kw High 24 1.24 15.91 66 2895 1.27 2.73 14.5 0.86 Low 6 0.63 8.08 48 1470 0.29 0.82 2.9 0.13 High 43 1.89 19.07 70 2945 2.53 5.25 31.5 1.54 Low 11 0.95 9.63 53 1490 0.58 1.68 5.4 0.23 High 52 2.02 21.64 66 2841 1.3 2.41 14.5 1.17 Low 16 1.02 10.87 57 1443 0.28 0.75 2.85 0.17 High 83 2.61 26.42 72 2900 2.53 5.25 31.5 2.74 Low 21 1.33 13.45 55 1475 0.58 1.68 5.4 0.42 Product Code Dia. A B C D E F G H J K L Weight kg JFR/F3-315 315 332 280 12 225 160 484 296 413 226 1806 437 60 JFR/F3-355 355 416 360 12 244 180 544 331 440 227 1816 442 81 JFR/F3-400 400 416 360 12 244 180 569 331 503 266 2345 520 100 4 HOLES C A B F G H J D E K L All dimensions are expressed in mm. All dba figures shown are free field sound pressure levels at 45 o to inlet/ outlet. All starting currents shown are direct online (DOL). Air density used in all figures is 1.2kg/m 3. Single speed options available. F200 & F400 variations available. Further details on request. Codes shown are for isolator versions. Terminal box version also available. 60Hz data available upon request. Impulse Ventilation 13

Performance & Dimensional Data Unflanged Units JetVent Unidirectional Standard Thrust Product Code Thrust N Volume Flow Rate m 3 /s Velocity m/s Sound Pressure dba @ 1m Speed r/min Motor Power kw JVSU-CPA-315 2-3 21 0.95 16.52 62 2960 0.80 1.91 11.46 0.45 FLC Amps SC Amps Absorbed Power kw JVSU-CPA-400 2/4-3 51/12 1.95/0.97 20.91/10.42 64/50 2855/1448 1.30/0.28 2.41/0.75 14.50/2.85 1.02/0.16 Product Code A B C D E F G H (max) Weight kg JVSU-CPA-315 380 450 350 400 25 14 335.5 1990 65 JVSU-CPA-400 380 450 395 445 25 14 427 2880 75 E A B H 14 Car Park Ventilation

Unflanged Units JetVent Truly Reversible Standard Thrust Product Code Thrust N Volume Flow Rate m 3 /s Velocity m/s Sound Pressure dba @ 1m Speed r/min Motor Power kw FLC Amps SC Amps Absorbed Power kw JVSR-CPA-315 2-3 20 0.96 16.73 64 2950 0.80 1.91 11.46 0.47 JVSR-CPA-400 2/4-3 52/13 2.02/1.02 21.64/10.87 55/57 2841/1443 1.30/0.28 2.41/0.75 14.50/2.85 1.17/0.17 Product Code A B C D E F G H (max) Weight kg JVSR-CPA-315 380 450 350 400 25 14 335.5 2098 65 JVSR-CPA-400 380 450 395 445 25 14 427 3030 75 E A B H All dimensions are expressed in mm. Motors shown are suitable for the following: General use at temperatures (ambient) +40 o C. One off high temperature use of 300 o C for 2 hour. 400Volt / 3 Phase / 50Hz electrical supply. All thrust figures are measured under test conditions. Volume flow and velocity figures shown may have been calculated in accordance with test requirements. All the test data shown has been prepared in accordance with ISO 13350 1999 / BS 848-10-1999. Impulse Ventilation 15

16 Car Park Ventilation

Induction Ventilation The ventilation level to be provided within the car park (in order to limit the concentration of carbon monoxide and other vehicle emissions and to remove smoke in the event of a fire) can be found in the relevant Building Regulations and in BS 7346-7:2006 Components for smoke and heat control systems. Code of practice on functional recommendations and calculation methods for smoke and heat control systems for covered car parks. 17

The Principles of JetVent JetVent induction fans have been specifically designed to provide a high velocity, laminar airflow in a reduced height profile to help overcome problems caused by obstructive structural beams and low overall ceiling heights found in car parks. The innovative design of JetVent induction fans provides major benefits in terms of reduced installation and running costs as well as effective smoke and contaminant removal. The induction ventilation system is based on a number of small, strategically located high velocity fans in place of the large and expensive distribution ductwork traditionally used in car parks. Induction fans operate on well-proven tunnel ventilation principles, producing a high velocity jet which adds momentum to the air in front of the fan imparting thrust to all the surrounding air through mixing and entrainment as it diffuses. The volume of entrained air is significantly greater than that passing through the fan. The induction fans are carefully positioned to direct the airflow towards the main extract fan intake points. The main extract fans are sized to provide the required flow rates, however, given the reduced need for, or complete elimination of ducting, the resulting reduction in system resistance means they are typically smaller and consume less energy. Induction fan performance is rated in terms of the thrust developed by the fan, which is the product of the mass flow rate times the change in velocity, i.e. volume flow rate times the air density times the fan outlet velocity, and is measured in Newtons. 18 Car Park Ventilation

Conventional & Induction Ventilation Conventional Ducted System Equivalent Impulse Layout Exhaust Point Ventilation Ducts Exhaust Point Induction Fans The distribution ducting used in traditional systems is replaced by a number of small JetVent centrifugal induction fans to direct the airflow across the designated area. Without the distribution duct resistance, smaller exhaust and supply fans and / or motors can be used. Induction ventilation for smoke movement Exhaust via smoke exhaust fans JetVent Induction Fan Zone of turbulent mixing Air Inlet Induction Ventilation 19

Features & Benefits The JetVent centrifugal induction range comprises 50N or 100N thrust types that conform to European Standard EN12101-3. The range is suitable for ambient temperature operation as well as once only, 2 hour high temperature smoke conditions up to 400 C. The two speed motor is suitable for frequency inverter speed control on high speed. Cost Effective JetVent provides the scope for reduced installation and overall construction build costs compared with traditional ducted systems. The high efficiency impellers make this a very economical method of moving high volumes of air. Ingress Protection A minimum protection to IP55 on electrics improves reliability and ease of cleaning by means of pressure washing components. The unit is supplied as standard with a fitted IP55 terminal box or an optional lockable fire rated isolator. Better Security The elimination or reduction in ductwork means a safer, lighter environment with better security due to the increased visibility. Rigorous Testing JetVent is independently tested to meet the exacting standards of EN 12101-3 for operating at 300 C for 2 hours. Performance is tested to BS848-10:1999 Fans for general purposes - Performance testing of jet fans. Robust Design The powder coated mild steel fan casing provides a robust construction, which is very resistant to potential corrosion. The integral guard is designed to protect against the rotating impeller parts. The guard is finger proof and bright zinc plated. Low Maintenance With no ductwork, maintenance costs are reduced as there is no ducting to become blocked, damaged or subject to leakage. Air Quality JetVent induction fans provide an improvement in air quality achieved by mixing the air more effectively, which means the potential risk of contaminant accumulation (beyond specific requirements) is overcome. Slim Profile The slim profile design of JetVent allows designers to overcome problems caused by obstructive structural beams and low overall ceiling heights, without compromising performance characteristics. 20 Car Park Ventilation

Performance & Dimensional Data Centrifugal Product Code JVC/F3B-50N-2-AI JVC/F3B-100N-2-AI Thrust N Volume Flow Rate m 3 /s Velocity m/s Sound Pressure dba @ 1m Speed r/min Motor Power kw FLC Amps SC Amps Absorbed Power kw High 54 1.62 28.82 67 1449 1.38 3.2 16 1.11 Low 12 0.80 14.00 40 733 0.35 1.36 4.08 0.21 High 100 2.65 33.19 72 1425 2.7 6.03 30.15 2.31 Low 18 1.35 16.84 55 729 0.68 2.26 7.23 0.43 Product Code A B C D E F G H J K Weight kg JVC/F3B-50N-2-AI 1359 380 790 102 836 880 27 12 273 75 113 JVC/F3B-100N-2-AI 1830 700 1147 102 1203 1247 27 12 332 70 146 A C E F D K J H G DETAIL A A B All dimensions are expressed in mm. Motors shown are suitable for the following: General use at temperatures (ambient) +40 o C. One off high temperature use of 300 o C for 2 hours. 400Volt / 3 Phase / 50Hz electrical supply. All thrust figures are measured under test conditions. Volume flow and velocity figures shown may have been calculated in accordance with test requirements. All the test data shown has been prepared in accordance with ISO 13350 1999 / BS 848-10-1999. dba figures are free field sound pressure levels at 45 o to the outlet. Induction Ventilation 21

22 Car Park Ventilation

Emergency Extract Ventilation Elta Fans have been manufacturing fans for over 40 years and are one of the founding members of the Smoke Control Association, which has been instrumental in shaping modern legislation. We were also the first company to have our entire range accredited to EN12101-3 the standard to which all four of our sites across the world manufacture. The SmokeVent range of axial flow fans has been specifically developed for emergency smoke spill extract systems to overcome hazardous fire, smoke and fume conditions. They may operate as part of the main extract system or as dedicated fans for emergency clearance. Our fans are of especially high design and manufacturing integrity and are made bespoke for the individual demands of the application in order to assure the safety and operation of the structure and its occupants. As high temperatures and smoke particulates can damage components, our fans have been robustly designed for continued operation in this arduous environment. SmokeVent Fans Our comprehensive range of SmokeVent fans are supplied for free-standing operation in ducted systems and are also suitable for installation in roof extract units. All fans are designed in accordance with EN12101-3 standards and can also be supplied to meet additional region or project specifications as required. With a broad range of sizes and variants we can flexibly supply models for new and refurbishment projects. Please contact Elta Fans for more information on +44 (0)1489 566500. Emergency Extract Ventilation 23

Fan Selection Program The Elta Fans Fan Selection Program has been designed to make fan selection faster and more efficient. Developed from the ground up, the selection program makes it quicker and easier for you to select fans from our expansive range of products. Whether you ve used the program previously or this is your first time, you will find this program a helpful part of your processes. Navigating the Program To navigate between the main areas of the program, simply use the main navigation buttons at the top. The program highlights the button to show which area of the program you are in. A dedicated help source is available with the ability to define common default settings. Basic Mode Selecting a Fan Basic mode: allows you to use a 5 step process to determine suitable fans, or alternatively, use a single Product Code. Advanced mode: gives you complete control over the criteria for selecting your fan. Silencers & Acoustic Analysis Silencer selection is available in both basic and advanced modes allowing a simple 5 step process to determine a suitable silencer or complete control over the criteria of the silencer type required. Advanced Mode The acoustic analysis tool allows calculations on simple systems to be made to provide a rough approximation of what noise level can be expected. Our Fan Selection Program has become the essential software for consultants and contractors who want fast and accurate fan and silencer selections. 24 Car Park Ventilation

Key Features The latest version has been designed to make it easier for you to select, compare and schedule fans and silencers with a number of powerful new features that will help you save time. ü A more user-friendly interface Easier to find what you need based on a wide choice of criteria ü Basic and advanced user modes With guidance, use the program at the level that suits you Revolutionary Support ü Revolutionary support for variable speed fans Helps you design more energy efficient systems ü Store all 2D.dwg and.dxf For a project in a folder in one quick step ü Conveniently view technical data In a single screen and recall it at any time ü Easily select energy efficient fans And calculate running costs Store All Files ü Fully integrated PDF and Excel output Promoting the efficient electronic flow of data and further compliment paperless offices Convenient Data View PDF Output Select Efficient Fans Please contact Elta Fans for more information on +44 (0)1489 566500 Fan Selection Program 25

Customer Service At Elta Fans, we pride ourselves on our integrity and reliability as a supplier. We respect that this is your project. To ensure that your project is the best it can be, when working with us, you get a partnership with as much or as little involvement from us as you need. We have a dedicated sales team with individuals who are specifically trained to be experts in their individual market. When you place an order with us, you are allocated a direct point of contact to ensure consistency throughout the sales process. Our dedicated projects team constantly monitor projects, giving customers updates on their order as often as they need them. From order processing to manufacture and all the way through to delivery, our dedicated aftersales team follow an established process to ensure we don t lose visibility of the project at any stage. 26 Car Park Ventilation

Certifications Elta Fans are committed to conforming to the highest standards. We hold a number of internationally recognised accreditations and certifications, in accordance with EN12103-3, including: Kite Mark KM613754 LPCB C937a-05 Certificate of Constancy of Performance 0086-CPR-493001 LPCB third party product certification schemes are quality assurance schemes comprised of full testing of a manufacturer s quality system and production procedures, regular audit testing, labelling and listing. LPCB certified products are accepted throughout the UK and around the world. We are also active members of professional organisations that help to shape and direct the research, legislation, trends and issues of the present and future including: All Elta Fans welders involved in the manufacture of JetVent products are coded to: ASME Boiler & Pressure Vessel Code Section IX (welding procedure qualification records & individual welder performance qualifications). BS ISO 15614-1:2004 A2:2012 Welding procedure qualifications records. ISO 9606-1:2013 Individual welder performance qualifications. FETA FMA EVIA CIBSE Patrons HEVAC Association BSRIA AMCA Smoke Control Association Smoke Control Association The Smoke Control Association (SCA) is an independent body of experts all involved in various aspects of the smoke control sector. The association works in many fields including the publication of guides related to smoke control systems and products. During the past 10 years, these guides have included methods for testing smoke extract fans, natural ventilators and smoke curtains which were subsequently adopted by BSI in the BS 7346 range of standards, ultimately being embraced in the EN12101 European Standards series. 27

17 Barnes Wallis Road, Segensworth East Industrial Estate, Fareham, Hampshire, PO15 5ST, United Kingdom Tel: +44 (0) 1489 566500 Fax: +44 (0) 1489 566555 Email: at@eltafans.co.uk Website: www.eltafans.com 02.18.V2