HARTZELL. Tempered Air Heating Equipment. Hartzell Fan, Inc., Piqua, Ohio

Similar documents
Direct Gas-Fired Make-Up Air

Indirect Gas-Fired Make-Up Air

Direct Fired Heater Model AD Specification

Modular Supply Make-Up Air Unit

Industrial Space Heating Direct Gas-Fired Heating. Greenheat 50/50 Recirculation

Schust Engineering, Inc. 701 North Street P.O. Box 128 Auburn, IN (260) Fax: (260)

Modular Heating & Ventilating Unit Model IGX-HV

Internal ridged board 1" x 1.5 foil face installation shall be installed on roof, walls and base of casing.

A. American National Standards Institute (ANSI): Establishes requirements applicable to certifying direct gas-fired heaters.

TGIF-1. Indirect Fired Heating Systems. Technical Guide for: IF Indoor Installations. IFW Outdoor Installations. Applied Air. Keeps You.

GLOBAL FINISHING SOLUTIONS

KINGS COUNTY JAIL EXPANSION PHASE III COUNTY OF KINGS SECTION

Contents INDEX. TDM Series Indirect Fired Heaters

Warm. IFR Indirect Fired Gas Heating Systems. Applied Air. Keeps You

A. General: Refer to paragraph entitled "SUBMITTAL" in Section Include the following data:

SECTION DIRECT GAS-FIRED INDUSTRIAL HEATING AND VENTILATING UNITS

Gas-Fired Indoor and Outdoor Duct Furnaces

Make-Up Air March 2012

Turning Air Into Solutions. TUBEAXIAL PAINT SPRAY BOOTH EXHAUST FANS. Model TCBS

Equipment Specifications

Counterflo CF BASIC COUNTERFLO HEATER RCF CURB MOUNTED ROOFTOP HEATER CFDF COUNTERFLO DUCT FURNACE INDIRECT-FIRED INDUSTRIAL HEATERS

Direct Gas-Fired Make-Up Air Models DG and DGX

SAS Steadyair Make-Up Air Units Technical Guide

FEATURES AND BENEFITS

Direct Gas-Fired Make-Up Air Models DGK, DG and DGX

UNIVERSITY SERVICES ANNEX James Madison University Harrisonburg, Virginia State Project Code: Architect s Project Number:

Combat. DF-Series Direct-Fired Heating, Cooling and Pressurization Systems. Equipment Specifications

INDIRECT GAS-FIRED AIR HEATER

THREE-WAY HEAT SAVER/VENTILATOR

KIC Air Curtains. Technical Guide

TYPICAL CPA SPECIFICATIONS

FAS Fresh Air Supply Units

Brown University Revised August 3, 2012 Facilities Design & Construction Standards SECTION AIR HANDLING UNITS

KEES, INC. Installation & Maintenance Manual DFG Series Direct Gas Fired Make-up Air Heaters. Table of Contents FOR YOUR SAFETY.

Directflow SBDR/SBD SERIES

BANANZA. B-Series Direct-Fired Heating, Cooling And Pressurization Systems. Equipment Specifications

Engineering Bulletin. Gas Heat. for M-Series and T-Series Climate Changer Air Handlers CLCH-PRB010-EN. March 2004

GA Gas Unit Heater Assemblies Technical Guide

Construction Standards Page Exclusively published and distributed by Architectural Computer Services, Inc. (ARCOM) for the AIA

UNIVERSITY OF ROCHESTER DESIGN STANDARDS NOVEMBER 1, 2013

A. American National Standards Institute (ANSI) : Establishes requirements applicable to certifying direct gas-fired heaters.

Introduction to Fans. The Basics of Fan Principles and Terminology

Directflow SBDR/SBD SERIES

AXICO ANTI-STALL CONTROLLABLE PITCH-IN-MOTION AND ADJUSTABLE PITCH-AT-REST VANEAXIAL FANS

SPECIFICATION DELETED SECTION CENTRIFUGAL HVAC FANS

DENVER PUBLIC SCHOOLS DESIGN AND CONSTRUCTION STANDARDS This Standard is for guidance only. SECTION EXHAUST FANS

Advance Release September 2009

Air Replacement Systems

Air Make-Up Units. Product Line Overview & Capabilities

SECTION AIR HANDLING UNIT

Air Replacement Systems

Fans: Features and Analysis

SECTION PACKAGED, OUTDOOR, CENTRAL-STATION AIR-HANDLING UNITS

UNIVERSITY OF MISSOURI Central Station Air-Handling Units March

Selecting the Correct Fan

1.1 This section applies to air handling units for HVAC Systems.

PGF SERIES 7-1/2 Ton. Belt Drive CONVERTIBLE SINGLE PACKAGE GAS/ELECTRIC UNIT

Field Start-Up Sheet Direct Fired Gas Equipment

Section (CSI ) I-Series Drum & Tube (04/23/10) Indirect-Fired Heating & Ventilating

STR-Series Indirect-Fired Air Turnover Units

Twin City Fan & Blower

GAS-FIRED PRESSURIZED LOW INTENSITY INFRARED HEATERS SERIES TLP

Submittal Data Performance Data Electrical Data

Refer to the Page 23 (inside back cover) for Model Nomenclature. Table of Contents

A. Codes and Standards that are Standard at the University:

SIOUX STEEL COMPANY GRAIN CONDITIONING EQUIPMENT. Fans, Heaters & Controls

Bulletin FH05 FUME EXHAUST

High Plume Blowers Suggested Specification Section (Master Format 1996) Suggested Specification Section (Master Format 2004)

A. Section includes Factory Packaged, Modular units, providing cooling and heating for air distribution systems.

48GS HIGH-EFFICIENCY SINGLE-PACKAGE GAS HEATING/ ELECTRIC COOLING UNITS

PGB SERIES 3thru5Ton 10 SEER CONVERTIBLE SINGLE PACKAGE GAS/ELECTRIC UNIT

The H Series. Pure and Simple Solutions. HTLV Space Heating

AIR HANDLERS. Central Station (CS3) Roof Mounted (RT) (Modular AL Frame AHU)

SECTION (15833) - HVAC POWER VENTILATORS

ENVIRO UNIT ENGINEERING MANUAL KES SERIES

Cabinet Unit Heaters Steam / Hot Water

Industrial Fans & Blowers

XeteX, Inc. All Rights Reserved.

MXI Mixed Flow Inline Fan

Twin City Fan & Blower

University of Houston Master Construction Specifications Insert Project Name

SKYPAK II, 3 Ton Series, gives you a

Installation & Service Instructions for Jackson & Church Flexaire Packaged Furnaces SDF-125 thru SDF-400 Gas Firing

RGE 13 A T - 1 A

MIN. CCT. QTY RLA LRA HP FLA AMPACITY /1/ /3/

Bulletin C6200 MAY Buffalo. Big Buffalo. Air Handling. Custom Applications

DCG Commercial. Submittal Data Form

DCC Series. Submittal Data Form 15- & 20-TON, THREE-PHASE PACKAGED AIR CONDITIONERS UP TO 11 EER

48SS018, 024, 030, 036, 042, 048 & 060 STANDARD-EFFICIENCY COMBINATION GAS HEATING/ ELECTRIC COOLING UNITS

Catalog Destiny Indoor Air Handler. Models Horizontal Configuration. Vertical Configuration

TECHNICAL GUIDE. Description SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS YD360, 480 & THRU 50 NOMINAL TONS YTG-B-0811

AMERICAN COOLAIR CORPORATION. Greenhouse Ventilation Systems. Farm Products Division

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS

Glossary of Terms Laboratory & Fume Exhaust Fans

SECTION AXIAL FANS

DSV Model Air Cooled Self Contained Indoor Packaged Units 3-5 Tons Preliminary Application Data

50HS018, 024, 030, 036, 042, 048 & 060 STANDARD-EFFICIENCY COMBINATION HEAT PUMP UNITS W/OPTIONAL ELECTRIC HEAT

DARTMOUTH COLLEGE DESIGN January 3, 2012 & CONSTRUCTION GUIDELINES

SECTION ROOFTOP REPLACEMENT AIR UNITS

Guide Spec Summary. Option List. Date: 05/21/2001. EarthWise Modular Climate Changer Full Spec. Prepared by: Phone Number: Prepared for:

Transcription:

Tempered Air Heating Equipment Series GFR GMC GMP SAH SCH SFC SMC SMP 77 78H 78V 79 811 Hartzell Fan, Inc., Piqua, Ohio 45356 January 2011

Index Hartzell Model Code Explanation..................... Page 2 Pictorial Table of Contents.......................... Page 3 Tempered Air Heating Equipment Function............ Page 4 Installation Configurations.......................... Page 5 Series GFR FC Centrifugal Recirculation Gas Unit.... Pages 6-9 Series GMP (Propeller) and GMC (Centrifugal) Gas Unit.............................. Pages 10-18 Series 78H and 78V Econo Gas Units............. Pages 19-20 Series 79 Gas Fired Door Heater................. Pages 21-22 Hartzell Model Code Explanation Motor Horsepower Horsepower 1 11/2 2 3 5 71/2 10 15 20 25 30 40 50 60 75 100 125 150 200 Code Letter H I J K L M N O P Q R S T U V W X Y Z How To Use Model Code Index: Example Assume a performance of 2,000,000 BTU/Hr and 20,000 CFM at 0 Ext. S.P. at standard conditions, with filters is required. Reading the Rating Table on Page 14, we find a Series SMP Steam Make-Up Air Propeller Fan Assembly with a 44 fan at the required performance. The model code can be constructed as follows: Type is Production (code A), Series is SMP, Size is 44, Number of blades is 3, Blade code is L. The fan is made of steel (code ST) with a totally enclosed fan cooled motor (code FC), motor HP is 3 (code K) and RPM/Voltage is 1750/460/60/3 (code 3). Notes: * 3 = Drive arrangement for DWDI or FC, belt drive centrifugal fans, AMCA standard 99-2404-78 = Close couple belt drive, propeller fans ** 1 = Centrifugal fan, Class I, per AMCA standard 99-2408-69, product definitions varies = Propeller fan number of blade for propeller *** Airflow delivery in thousands @ standard density (0.075 lbs/ft 3 ) This Tempered Air Bulletin bulletin lists the majority of Hartzell s line of Gas and Stream Intake Units and accessories. More than 70 Hartzell offices can **** provide ST = specific Steelperformance and installation data to meet your requirements. Call your Hartzell representative for assistance. Visit our website () GL = Galvanized or Steel call toll-free for the name of your Hartzell representative... GN = Galvannealed Steel 1-800-336-3267 Series 811 Gas Shaft Heater........................ Page 23 Series SFC Centrifugal Steam Heater............. Pages 24-25 Series SMP Propeller Fan Steam Unit............ Pages 26-29 Series SMC Centrifugal Steam Unit.............. Pages 30-31 Series SAH (Axial) and SCH (Centrifugal) Face & Bypass......................... Pages 32-35 Series 77 Steam Unit Heaters................... Pages 36-37 Options and Accessories...................... Pages 38-39 Type A S M P - 4 4 3 L 2 0 S T FC K 3 A - Production Item I - IRI Plumbing (Gas only) F - FM Plumbing (Gas only) Product Series Arrangement* Size (nominal wheel diameter, inches) No of Blades/Class** Blade/Wheel Unit CFM*** Material of Construction**** Motor Enclosure Motor Horsepower Motor RPM/Phase All other informational fields must be filled with hyphens/dashes ( ) if they are not applicable to the fan being considered. Motor RPM/Volt/Phase 2 = 3450/230/460/60/3 3 = 1750/230/460/60/3 4 = 1140/230/460/60/3 5 = 870/230/460/60/3 6 = 690/230/460/60/3 7 = 575/230/460/60/3 This bulletin lists Hartzell s complete line of Make-Up Air Units and accessories. More than 70 Hartzell offices can provide specific performance and installation data to meet your requirements. Call your Hartzell representative for assistance. Visit our website () or call toll-free for the name of your Hartzell representative... 1-800-336-3267 2

Tempered Air Heating Equipment Series GFR FC Centrifugal Gas Air Make-Up Heater with Air Recirculation Page 6 Series GMP/GMC Propeller/Centrifugal Gas Air Make-Up Heater Page 10 Series 78H/78V Econo Gas Heater Page 19 Series 79 Gas Fired Door Heater Page 21 Series 811 Gas Shaft Heater Page 23 Series SFC Centrifugal Steam Heater Page 24 Series SMP Propeller Steam Make-Up Air Page 26 Gas Fired Standards and Certifications F.M. I.R.I. Series SMC Centrifugal Steam Make-Up Air Page 30 Series SAH/SCH Steam Face and Bypass Units Page 32 Series 77 Steam Unit Heaters Page 36 Factory Mutual Engineering and Research encompasses the Factory Mutual Research Corporation and the Factory Mutual Engineering Association. These groups provide research, standard development and product testing and approval. In addition, FMEA provides property loss prevention consulting services. Hartzell Direct Gas Fired Forward Curved Make-Up Air Heaters are available built to FM loss prevention guidelines, for field acceptance by FM for insurance purposes. Industrial Risk Insurers is a highly respected risk insurance company. Hartzell Gas Fired Make-Up Air Heaters are available built in accordance with the designs and features set forth in I.R.I. Publication No. IM.4.3.1 Space Heaters. 3

Function Air removed by exhaust systems must be replaced systematically by outside air. If this is not done, the exhaust system, while in operation, creates a negative pressure inside the building. The negative pressure conditions created reduce the overall effectiveness of the exhaust and ventilating systems of the entire plant. Smoke, fumes or corrosive vapors from manufacturing processes will build up, making personnel uncomfortable and reducing their efficiency. In the winter months, make-up air provides a dual function of supplying tempered outside air for heating as well as air to balance the system. If a negative pressure exists, hot and cold spots are likely to develop since airflow is not uniform throughout the building. Workers near windows and other openings are subject to cold drafts. The infiltration of cold air overloads the existing heating system in the winter, thus reducing its efficiency. The installation of a heated make-up air system will eliminate these negative pressure problems in the plant. Both the central heating system and the exhaust or ventilating system will be restored to full operating efficiency. Advantages of make-up air in your plant: 1. Worker comfort and efficiency increase because dust, fumes and contaminants can be removed efficiently by the existing exhaust systems. 2. Bothersome drafts and cold spots are eliminated. 3. Stacks on ovens, boilers and other direct or indirect fired equipment are restored to full efficiency. 4. Overloaded plant heating systems are returned to normal operation. 5. Water condensation problems are reduced or eliminated. 6. Low initial equipment cost (assuming boiler capacity is already available) on steam units. 7. No elaborate safety controls resulting in few nuisance shutdowns. 8. Simple control system and therefore electrical maintenance is simplified. 9. Minimal safety hazards. A Single Package Assembly Gas The Hartzell gas fired units produce very low levels of CO and are easy to maintain. Base unit consists of fan and burner sections. Many optonal features are available. Steam The Hartzell steam make-up air unit is a single package assembly. The standard unit includes fan, housing, steam coil, and shutter, pre-wired except for the steam valve. (Plumbing and valve wiring are supplied by the customer at the job site.) The standard control package provides for constant discharge air temperature, and low temperature shutdown to protect against coil freeze-up. 4

Installation Configurations Typical installation configurations are listed below. These are offered for your guidance and consideration. Accessories are also available to complete your packaged installation. Ductwork is not provided by Hartzell. Hartzell Direct Gas Fired Make-Up Air Heaters are designed for installation on crossbeams as standard. Optional perimeter curb mounting construction is available as an option. Limited vertical installation configurations for full size units are available. Please contact the factory. Air Recirculating Feature: Optional manual or automatic modulating air circulation is available on centrifugal models GFR and GMC. For sizes above 60,000 CFM contact factory.. Horizontal Unit Installed Inside The Building Series 86 Steam Type C or D PROPELLER CENTRIFUGAL 3,000 to 100,000 CFM 3,000 to 100,000 CFM Horizontal Unit Installed Outside The Building PROPELLER CENTRIFUGAL ECONO 78H 3,000 to 100,000 CFM 3,000 to 100,000 CFM 7,100 to 28,000 CFM PROPELLER CENTRIFUGAL GFR 3,000 to 100,000 CFM 3,000 to 100,000 CFM 2,000 to 60,000 CFM Vertical Installations 78V PROPELLER CENTRIFUGAL GFR 3,000 to 100,000 CFM 3,000 to 100,000 CFM 2,000 to 60,000 CFM VARIES WITH CONDITION PLEASE CONTACT FACTORY 5

Model GFR Forward Curved Centrifugal Gas Air Make-Up with Air Recirculation Features Construction Features Direct Gas Fired Forward Curved Make-Up Air Heaters, Model GFR, are rated for 2,000 CFM (200,000 BTU/Hr) through 60,000 CFM (9,788,850 BTU/Hr). Units sized 2,000 CFM through 30,000 CFM utilize a single, DWDI forward curve blower. Units 35,000 CFM through 60,000 CFM utilize twin, DWDI forward curve blowers. These units are best suited for applications through 2 1/2 external static pressure. Hartzell Model GFR units are completely packaged. Units are factory assembled and tested before shipment. Basic units 2,000 CFM through 30,000 CFM, will ship in 1 piece, while 35,000 CFM through 60,000 CFM units will ship in 2 pieces. These units are easy to install, easy to operate, lightweight, low in cost and low in maintenance. Model GFR Twin (Right Hand Controls Pictured) Standard Features Unit housings are constructed of 16-gauge G-90 galvanized steel. The basic unit consists of a fan and burner section, NEMA 4/12 control cabinet, plumbing, burner/recirculating air section and inlet bird screen. Both the electrical control cabinet and plumbing are mounted externally. Roofs are peaked to resist water penetration and collection. On sizes 15,000 CFM through 60,000 CFM, units have a standing seam roof. Standard mounting position for control cabinets and plumbing is on the right hand side of the unit. The access door will be opposite the control cabinet (left hand side). Standard right hand control position is determined by facing into the airstream. Left hand controls are optional. Lifting lugs are standard on all units. The air recirculation feature on Model GFR is designed to provide continuous building air make up, pressurization, and heating with maximum efficiency. These self-contained units are fully factory wired, plumbed, assembled and tested. They are designed to provide control of the make up air volume, via building pressure, or manually adjusted potentiometer located on the remote station. Units are direct fired, designed to burn either natural gas or propane with 20% to 100% fresh air intake and 0% to 80% recirculated air. This allows recirculation of clean plant air when heating, pressurization requirements and exhaust loads are at minimum levels. Motorized recirculation and profile plate dampers are standard. Remote stations with Fan, Off, and Heat selector switch and recirc control is standard. Fan motors mounted in the airstream as standard. Drives are fixed pitch type with belts that are oil, heat, and static resistant. Relubricable pillow block bearings are standard, with a minimum L10 life of 30,000 hours. Burners are Maxon Type NP-LE with a maximum 25:1 turn down ratio with natural gas or 20:1 turndown ratio with propane gas. The standard temperature control system is Maxitrol Series 14, which controls the discharge duct temperature. Standard units can develop a maximum discharge temperature of 90 F. 6 Control Panel (door removed) Type IRI Gas Plumbing Train Basic Operation and Controls Hartzell Model GFR Direct Gas Fired Forward Curved Make- Up Air Heaters with Air Recirculation Features are provided with a control system as standard. This system includes the master control panel mounted in a NEMA 4/12 enclosure. It consists of the motor starter, disconnect switch, control transformer, terminal strips, flame management system, burner modulation control and temperature controls. Standard control package includes state-of-the-art, commercially available components such as Maxitrol air temperature control system, and Fireye or Honeywell flame safeguard. Specific models may change depending on optional controls specified. Optional Controls Maxitrol Series 44 air temperature control system. Permits maximum control of space temperature Room override station Maxitrol 14 only Pre-purge timer Circuit Analyzer Lights Programmable timers Mild weather stat Clogged filter indicator Service light & receptacle Exhaust fan interlock English text readout Flame-Out indicator Smoke detector Access door interlock switch

Optional Features Motor operated center pivoted damper with channel frame and 16-gauge galvanized steel blades. Typical installation is at air discharge, or air entering end. Motor operator is interlocked with unit controls. Filter cabinet 16-gauge galvanized steel construction with reinforced self-forming flanges. This separate modular accessory contains a side access door for access to the filter frame, which has a double V arrangement. Disposable filters come standard with the filter box. Permanent filters available. Filter boxes for intake side of burner only. Intake weatherhood 16-gauge galvanized steel. Outdoor construction requires a plumbing cover over complete plumbing train. Discharge boot for attaching customer s ducting. 2- & 4-way discharge diffusers available. Perimeter curb mount accommodates weather and leakage protection when the unit is mounted on a full perimeter pre-fabricated roof curb. Pre-fabricated roof curb full perimeter mount with built-in wooden nailer strip that facilitates fastening the unit to the curb. Includes a rigid 1 1/2 thick 3 lb. density glass fiber liner that eliminates condensation problems. 1/4 neoprene sealer strip is standard. Construction is galvanized steel with fully welded seams. Optional Outlet Damper Adjustable Profile Blades Recirc Units Only Burner Optional Inlet Damper Outside Air Recirculated Air Adjustable Recirculating Dampers OFF Summer Winter Set selector to SUMMER for untempered air; to WINTER for heated air. Airflow switch does not permit burner to ignite if airflow is inadequate. High-temperature limit shuts unit off if discharge temperature rises over 140 F set point. Combination high-and-low gas pressure switch shuts off burner if pressure fluctuates excessively. Return Air Recirculating Unit Controls Manual Operation During down-time recirculating shutters are closed. Upon start-up, Recirc Shutter moves to whatever position the Return Air controller is set, up to 80% recirc air. The Shutter at the Burner moves conversely to the above Recirc Shutter, maintaining proper velocity across the burner. Flame Safeguard monitors normal startup. Closes main gas valve instantly upon flame failure. Automatic gas shut-off valve opens after all safety devices are satisfied and gas pilot is ignited and proved by flame safeguard. Automatic Operation Automatic modulation for face- and Recirc Dampers. Dampers are modulated based on internal building pressure. Set point can be adjusted on controller at remote station. If a pressure signal is supplied, a controller reads the signal and compares it to the controller setpoint. Discharge temperature controller maintains constant discharge air temperature. Modulating solenoid opens/closes gas valve as ordered by controller. The controller then provides an output signal to the damper actuators to modulate the return air and burner (outside air) dampers. This maintains proper airflow velocity across the burner. 7

Performance ON BTU/Hr External Static Pressure @ 90 1/4 1/2 1 1 1/2 2 21/2 Model Number CFM Temp Rise RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP _GFR3--21FC--2GLFC_3 2,000 200,000 838 3/4 915 3/4 1312 1.5 1458 1.5 1603 2 2018 2 _GFR3--31FC--3GLFC_3 3,000 300,000 694 1 768 1.5 895 1.5 1233 2 1339 3 1447 3 _GFR3--41FC--4GLFC_3 4,000 400,000 714 1.5 782 2 907 2 1019 3 1118 3 1209 5 _GFR3--51FC--5GLFC_3 5,000 500,000 744 2 806 2 925 3 1028 3 1129 5 1223 5 _GFR3-101FC-10GLFC_3 10,000 1,000,000 598 5 638 5 715 7.5 789 7.5 876 10 960 10 _GFR3-151FC-15GLFC_3 15,000 1,500,000 446 7.5 481 7.5 547 10 610 10 683 15 850 15 _GFR3-201FC-20GLFC_3 20,000 2,000,000 412 10 441 10 498 15 553 15 627 20 665 20 _GFR3-251FC-25GLFC_3 25,000 2,500,000 339 10 413 15 463 15 512 20 558 20 658 25 _GFR3-301FC-30GLFC_3 30,000 3,000,000 354 15 378 15 423 20 467 20 509 25 549 30 _GFR3-352FC-35GLFC_3 35,000 3,500,000 475 20 507 20 567 25 624 25 679 30 750 40 _GFR3-402FC-40GLFC_3 40,000 4,000,000 412 20 441 20 498 25 580 30 623 40 665 40 _GFR3-452FC-45GLFC_3 45,000 4,500,000 370 20 399 20 453 25 505 30 569 40 610 50 _GFR3-502FC-50GLFC_3 50,000 5,000,000 386 25 413 25 463 30 512 40 558 40 621 60 _GFR3-552FC-55GLFC_3 55,000 5,500,000 342 25 367 25 415 30 464 40 557 50 599 50 _GFR3-602FC-60GLFC_3 60,000 6,000,000 354 30 378 30 423 40 467 40 512 50 606 60 NOTES: CFM shown is net flow at discharge, and includes internal static pressure loss for fan and burner sections. When applying inlet damper add 1/8 Ext. S.P. When applying washable filters, add 1/8 Ext. S.P. When applying disposable filters, add 1/4 Ext. S.P. BHP includes drive losses. Standard motor is ODP, mounted in airstream, with 1.15 service factor. Specify motor nameplate HP rating accordingly. Principal Dimensions FAN & BURNER HOUSE (SIDEBLAST DISCHARGE) A I R F L O W OFF S Model No. J S GFR2-5 36 94 GFR10 36 111 GFR15 36 GFR20 48 138 GFR25 GFR30 48 144 GFR35 GFR40 48 144 GFR45 GFR50 48 144 GFR55 GFR60 48 144 FILTER HOUSE ACCESS DOOR 30 1/8 SAFETY GUARD (WIRE MESH) STANDARD ITEM AT INTAKE OF UNIT. J 8

ON Principal Dimensions C D 30 1/8 12 J OFF ACCESS DOOR INLET WEATHERHOOD (OPTIONAL) L DISCHARGE OPENING A I R F L O W A I R F L O W K SAFETY GUARD (WIRE MESH) STANDARD ITEM AT INTAKE OF UNIT. 4 TYPICAL DISCHARGE OPENING L FAN HOUSE (DOWNBLAST DISCHARGE) 2 TYPICAL FAN HOUSE (HORIZONTAL DISCHARGE) E. F RECIRC OPENING FILTER HOUSE (OPTIONAL) INLET DAMPER BOOT (OPTIONAL) A M INSIDE HSG. O.D. DISCHARGE N 8 A M INSIDE HSG. O.D. DISCHARGE N 8 B INSIDE HSG. 17 MAX. 17 MAX. PLUMBING COVER PLUMBING COVER RECIRC OPENING G DISCHARGE END DOUBLE WIDTH BLOWER H G. RECIRC OPENING Model No. CFM Range Max. Motor Frame Housing I.D. A B C D E F G H J K L M N GFR5 2-5,000 184T 41 32 2 94 46 17 14 3 4 13 1 8 7 3 16 19 18 7 8 11 1 16 36 1 2 GFR10 10,000 215T 52 44 2 111 59 3 8 23 20 3 4 15 5 8 9 11 16 28 25 13 1 2 GFR15 15,000 254T 88 9 16 28 26 1 2 21 1 4 11 9 16 34 1 2 31 1 2 18 3 4 69 58 2 138 57 GFR20 20,000 256T 86 1 16 33 30 19 1 2 13 11 16 37 1 2 34 1 2 17 1 4 GFR25 25,000 284T 37 1 2 21 3 4 15 3 16 40 37 22 81 66 2 144 92 1 2 33 57 GFR30 30,000 286T 40 1 2 20 1 4 13 3 16 46 1 4 40 1 4 20 3 8 GFR35 35,000 324T 92 13 16 79 23 3 8 12 1 16 34 1 2 87 3 4 22 1 8 132 58 2 144 23 57 GFR40 40,000 324T 93 15 16 90 1 2 18 5 8 15 1 16 37 1 2 96 1 4 17 7 8 GFR45 45,000 326T 93 1 16 81 3 4 148 66 2 144 28 GFR50 50,000 364T 92 1 16 90 3 4 GFR55 55,000 326T 93 1 2 28 98 162 66 2 144 GFR60 60,000 364T 91 11 16 33 92 1 2 22 5 8 57 16 9 16 40 103 3 4 22 1 8 24 5 8 57 14 1 2 46 1 4 112 3 4 24 5 8 NOTE: Dimensions subject to change. Certified prints available. Units with recirculating features contact factory for dimensions. Model Number CFM Fan Burner Filter Inlet Hood (Lbs.) Quantity & Size Range Section (Lbs.) Section (Lbs.) Box (Lbs.) Horiz. Only Filters Req d _GFR3--21FC--2GLFC_3 2-5000 679 195 107 (4) 20 x 25 x 2 _GFR3-101FC-10GLFC_3 10,000 1,035 255 131 (6) 16 x 25 x 2 (3) 20 x 25 x 2 _GFR3-151FC-15GLFC_3 15,000 1,252 (12) 16 x 25 x 2 345 252 _GFR3-201FC-20GLFC_3 20,000 1,643 (4) 20 x 25 x 2 _GFR3-251FC-25GLFC_3 25,000 1,804 _GFR3-301FC-30GLFC_3 30,000 2,296 401 337 (20) 20 x 25 x 2 _GFR3-352FC-35GLFC_3 35,000 1,186 1,198 (8) 16 x 25 x 2 490 394 _GFR3-402FC-40GLFC_3 40,000 1,531 1,312 (16) 25 x 20 x 2 _GFR3-452FC-45GLFC_3 45,000 1,828 1,461 (15) 16 x 25 x 2 590 432 _GFR3-502FC-50GLFC_3 50,000 1,828 1,481 (25) 20 x 25 x 2 _GFR3-552FC-55GLFC_3 55,000 2,273 1,497 _GFR3-602FC-60GLFC_3 60,000 2,273 1,497 625 472 (40) 20 x 25 x 2 9

Model GMP (Propeller Fan) Model GMC (Centrifugal Fan) Construction Features The Hartzell pre-engineered make-up air systems, when properly applied, eliminate hot and cold spots, supplying fresh clean air at the right temperature. Existing ventilation systems will work better, which accommodates more effective employees and production systems. Hartzell offers a broad range of axial and centrifugal models. These are modular units that can be configured to meet your requirements. Hartzell gas fired intake units are completely packaged, factory assembled and tested before shipment. These units are easy to install, easy to operate, low in cost and low in maintenance. GMC with Optional Filter Box Standard Features Axial (GMP) 3,000 through 100,000 CFM (300,000 through 10,000,000 BTU/HR) at 92 F temperature rise. 24 through 85 cast aluminum propeller fan. Ideal for low static pressure applications through 1/2 w.g. Centrifugal (GMC) 3,000 through 100,000 CFM (300,000 through 10,000,000 BTU/HR) at 92 F temperature rise. 15 through 54 DWDI (Double Width Double Inlet). Class I ideal for applications through 2 static pressure w.g. Unit 16 gauge galvannealed steel painted on the outside. The unit has internal self-formed flanges. Basic unit consists of fan section and burner section. All sections include formed steel mounting rails. Inlet bird screen is standard. Roofs are peaked to resist water penetration and collection. Controls and plumbing train are contained in a weatherproof enclosure outside the airstream. They are located on the right side of the unit (facing air discharge) as standard. Location on left side may be specified. Belt Drive All models have the fan motor in the airstream, belts are oil, heat and static resistant. Relubricable pillow block bearings are standard with a minimum L-10 life of 50,000 hours. Fixed drives are standard. Burner Maxon Series NP-LE burner with a maximum turn down ratio 25:1 with natural gas or 20:1 turndown ratio with propane gas. Maxitrol Series 14 air temperature control system. Controls discharge duct air temperature. Standard unit develops a maximum discharge temperature of 90 F. For optional discharge temperatures, contact factory. 10

Basic Operation and Controls All Hartzell Model GMP and GMC direct gas fired make-up air heaters are provided with a control system as standard. This system includes the master control panel mounted in a Nema 4/12 external control cabinet enclosure. It consists of the motor starter, or control transformer, terminal strips, airflow switch, flame management system, burner modulation control and temperature controls. Standard control package includes state-of-the-art, commercially available components such as Maxitrol air temperature control system, Honeywell Series 7800 flame safeguard system and electronic temperature and passive limit controls. Specific models may change depending on optional controls specified. A description of the Hartzell controls follows: Optional controls such as remote station, which is typically mounted at the floor level and consists of start and stop push buttons and fan/heat selector switch. Optional Remote Station Control Panel/Gas Plumbing Train Additional optional controls such as pre-purged timers, room temperature controllers and programmable timers are also available. English text readout Circuit analyzer lights Motor operated intake or discharge shutter Remote discharge air temp control Mild weather stat Clogged filter indicator Self-checking scanner Service light & receptacle Exhaust fan interlock Smoke sensors Recirculation feature Standard Unit Controls (Propeller or Centrifugal) OFF Summer Winter Set selector to SUMMER for untempered air; to WINTER for heated air. A description of the Hartzell optional recirculating unit controls, both manual and automatic follows: Airflow switch does not permit burner to ignite if airflow is inadequate. High-temperature limit shuts unit off if discharge temperature rises over 140 F set point. Combination high-and-low gas pressure switch shuts off burner if pressure fluctuates excessively. Flame Safeguard monitors normal start-up. Closes main gas valve instantly upon flame failure. Return Air Optional Recirculating Unit Controls Manual Operation Optional Face and Recirc Feature: During downtime, recirculating shutters are closed. Upon start-up, Recirc Shutter moves to whatever position the Return Air controller is set, up to 80% recirc air. The Shutter at the Burner moves conversely to the above Recirc Shutter. Automatic gas shut-off valve opens after all safety devices are satisfied and gas pilot is ignited and proved by flame safeguard. Discharge temperature controller maintains constant discharge air temperature. Automatic Operation Automatic modulation for face- and Recirc Dampers. Dampers are modulated based on internal building pressure. Set point can be adjusted on controller at remote station. If a pressure signal is supplied, a controller reads the signal and compares it to the controller setpoint. Modulating solenoid opens/closes gas valve as ordered by controller. The controller then provides an output signal to the damper actuators to modulate the return air and burner (outside air) dampers. This maintains proper airflow velocity across the burner. 11

Optional Features Maxitrol Series 44 air temperature control system. Permits maximum control of space temperature. Motor operated center-pivoted shutter with channel frame and 16 gauge steel blades. Typical installation is at air discharge end. Shutter motor operator is interlocked with unit controls. Filter cabinet 16 gauge galvannealed steel construction with reinforced self-forming flanges. This separate modular accessory contains a side access door for access to the filter frame, which has a double V arrangement. Disposable filters come standard with the filter box. Permanent filters available. Only inlet mounting available. Intake weatherhood 16 gauge galvannealed steel. Turning elbows turn the inlet or discharge airflow 90 with the aid of guide vanes. Centrifugal units discharge may be set for downblast vertical construction. Service platform constructed to comply with safety code (OSHA) for horizontal units. 2- & 4-way discharge diffusers available. Perimeter curb mount accommodates weather and leakage protection when the unit is mounted on a full perimeter prefabricated roof curb. Prefabricated roof curb full perimeter mount with built-in wooden nailer strip that facilitates fastening the unit to the curb. Includes a rigid 1 1 ¼2 thick 3-lb. density glass fiber liner, which eliminates condensation problems. 1/4 neoprene sealer strip is standard. Construction is galvanized steel with fully welded seams. Optional Recirculation Features (GMC model shown) Air recirculation feature available on both centrifugal (GMC) and propeller (GMP) models, is designed to provide continuous building air make-up, pressurization, and heating with maximum efficiency. These self-contained units are fully factory wired, plumbed, assembled and tested. They are designed to provide control of the make-up air volume, via pressure or manually adjusted potentiometer. Units are direct fired, designed to burn either natural gas or propane with 20% to 100% fresh air intake and 0% to 80% recirculated air. This allows recirculation of clean plant air when heating, pressurization requirements and exhaust loads are at minimum levels. 12

Performance Model GMP Performance (Propeller Fan) 0 S.P. 1/8 S.P. 1/4 S.P. 3/8 S.P. 1/2 S.P. Model Number CFM BTU/HR RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP _GMP---31-L--3GNFC_3 3,000 300,000 1620 1.2 1726 1.5 1820 1.7 1905 2.0 1981 2.3 _GMP---51-L--5GNFC_3 5,000 500,000 1710 1.5 1825 1.8 1936 2.1 2044 2.4 2148 2.8 _GMP---71-L--7GNFC_3 7,000 700,000 1324 2.1 1406 2.6 1482 3.0 1556 3.5 1626 4.0 _GMP--101-L-10GNFC_3 10,000 1,000,000 1393 2.4 1497 2.9 1590 3.5 1672 4.1 1746 4.7 _GMP--121-L-12GNFC_3 12,500 1,250,000 1200 3.2 1268 3.8 1336 4.5 1402 5.3 1467 6.1 _GMP--151-L-15GNFC_3 15,000 1,500,000 1291 3.9 1347 4.4 1404 5.1 1461 5.8 1517 6.6 _GMP--201-L-20GNFC_3 20,000 2,000,000 898 5.3 963 6.5 1023 7.8 1080 9.2 1131 10.5 _GMP--251-L-25GNFC_3 25,000 2,500,000 952 6.4 1001 7.4 1051 8.6 1103 9.9 1155 11.3 _GMP--301-L-30GNFC_3 30,000 3,000,000 1041 8.3 1079 9.3 1118 10.3 1157 11.5 1198 12.7 _GMP--351AA-35GNFC_3 35,000 3,500,000 1133 9.3 1174 10.3 1217 11.5 1260 12.7 1304 14.0 _GMP--401-L-40GNFC_3 40,000 4,000,000 927 12.5 963 14.2 1001 16.1 1041 18.2 1083 20.5 _GMP--451-L-45GNFC_3 45,000 4,500,000 995 15.1 1025 16.8 1056 18.6 1088 20.6 1122 22.7 _GMP--501-L-50GNFC_3 50,000 5,000,000 852 14.9 880 16.6 909 18.3 938 20.1 967 22.0 _GMP--601AA-60GNFC_3 60,000 6,000,000 880 19.6 880 21.9 880 24.2 880 25.8 880 28.2 _GMP--751AA-75GNFC_3 75,000 7,500,000 604 19.3 623 21.4 641 23.6 660 25.8 678 28.1 _GMP--901AA-90GNFC_3 90,000 9,000,000 537 19.6 558 22.1 580 24.7 601 27.5 621 30.2 _GMP-1001AA100GNFC_3 100,000 10,000,000 535 23.5 556 26.3 576 29.2 596 32.2 614 35.3 Model GMC Performance (Centrifugal Fan) 1/2 S.P. 1 S.P. 1 1/2 S.P. 2 S.P. BC Wheel BA Wheel BC Wheel BA Wheel BC Wheel BA Wheel BC Wheel BA Wheel Model Number CFM BTU/HR RPM BHP RMP BHP RPM BHP RMP BHP RPM BHP RPM BHP RPM BHP RMP BHP _GMC3--31B_--3GNFC_3 3,000 300,000 1387 1.1 N/A N/A 1522 1.4 N/A N/A 1652 1.7 N/A N/A 1780 2.1 N/A N/A _GMC3--51B_--5GNFC_3 5,000 500,000 1765 2.4 N/A N/A 1888 2.9 N/A N/A 1994 3.3 N/A N/A 2090 3.8 N/A N/A _GMC3--71B_--7GNFC_3 7,000 700,000 1256 3.4 1365 3.3 1347 4.2 1465 4.0 1435 5.0 1560 4.7 1520 5.7 1650 5.4 _GMC3-101B_-10GNFC_3 10,000 1,000,000 1494 6.1 1630 5.5 1574 7.0 1710 6.4 1648 7.9 1790 7.4 1717 8.8 1865 8.3 _GMC3-121B_-12GNFC_3 12,500 1,250,000 1108 6.7 1205 6.2 1177 7.9 1280 7.4 1242 9.1 1350 8.6 1306 10.4 1415 9.9 _GMC3-151B_-15GNFC_3 15,000 1,500,000 1219 9.1 1330 8.3 1284 10.5 1395 9.7 1344 11.9 1460 11.1 1401 13.3 1525 12.5 _GMC3-201B_-20GNFC_3 20,000 2,000,000 905 10.1 975 9.5 965 11.9 1030 11.1 1023 13.8 1080 12.8 1080 15.8 1135 14.5 _GMC3-251B_-25GNFC_3 25,000 2,500,000 1021 14.7 1110 13.8 1071 16.9 1160 15.9 1120 19.1 1205 17.9 1168 21.4 1250 20.0 _GMC3-301B_-30GNFC_3 30,000 3,000,000 773 15.6 795 13.9 820 18.4 840 16.3 865 21.3 885 18.7 907 24.3 925 21.3 _GMC3-351B_-35GNFC_3 35,000 3,500,000 838 20.2 865 18.1 883 23.3 905 20.8 925 26.6 945 23.6 965 29.9 985 26.4 _GMC3-401B_-40GNFC_3 40,000 4,000,000 735 22.0 755 19.7 776 25.7 795 22.8 815 29.5 835 26.0 852 33.5 870 29.3 _GMC3-451B_-45GNFC_3 45,000 4,500,000 784 27.1 815 24.3 825 31.1 850 27.8 862 35.3 885 31.1 897 39.5 920 34.9 _GMC3-501B_-50GNFC_3 50,000 5,000,000 710 32.6 730 28.9 745 37.2 760 32.9 778 42.0 795 37.0 810 46.9 825 41.2 _GMC3-601B_-60GNFC_3 60,000 6,000,000 782 44.3 810 39.7 815 49.7 840 44.4 846 55.2 870 49.1 876 60.7 895 53.8 _GMC3-751B_-75GNFC_3 75,000 7,500,000 530 37.2 550 33.4 563 44.0 580 39.3 593 50.8 605 45.1 621 57.9 635 51.1 _GMC3-901B_-90GNFC_3 90,000 9,000,000 591 52.8 625 47.7 623 60.8 650 54.7 652 68.9 675 61.7 679 77.0 700 68.7 _GMC31001B_100GNFC_3 100,000 10,000,000 634 65.5 675 59.4 664 74.5 700 67.2 693 83.5 720 75.1 719 92.4 745 82.9 NOTES: CFM shown is net flow at discharge, and includes internal static pressure loss for fan and burner sections. When applying damper, add 1/8 Ext. S.P. When applying washable filters, add 1/8 Ext. S.P. When applying disposable filters, add 1/4 Ext. S.P. When applying evaporative cooling module, add 1/4 Ext. S.P. BHP does not include drive losses. Standard motor is ODP, mounted in airstream, with 1.15 service factor. Specify motor nameplate HP rating accordingly. 13

Principal Dimensions N TYP A INSIDE HSG. 10 L TYP GENERAL PLAN VIEW E SQ. C PITCH FAN I.D. J K SQ. DISCHARGE OPENING B INSIDE HSG. AIRFLOW BLOWER HOUSE BURNER HOUSE PLUMBING/ELECTRICAL FILTER HOUSE INLET WEATHER HOOD DISCHARGE END (OPTIONAL SHUTTER NOT SHOWN) 1/2 DIA. HOLD H REQ'D CURB MOUNT CONST. (OPTIONAL) Principal Dimensions (Inches) Model GMP Model CFM Fan Max Motor Housing I.D. No. Range Size Frame A B C D E G H J K T U _GMP3 3,000 24 182T _GMP5 5,000 24 182T 50 36 6 4 28¼ 30 20 24 26 ¾ ¾ _GMP7 7,000 32 184T _GMP10 10,000 32 184T 56 45 8 4 36¼ 40 20 32 34 1 ¾ _GMP12 12,500 36 213T _GMP15 15,000 36 213T 69¼ 53 8½ 4 40¼ 60 20 36 38 1½ ¾ _GMP20 20,000 48 254T _GMP25 25,000 48 254T 79 63 10 4 52¼ 60 20 48 50 2 1 _GMP30 30,000 48 254T _GMP35 35,000 48 256T 89 76 10 6 52¼ 80 20 48 50 2 1 _GMP40 40,000 54 284T _GMP45 45,000 54 284T 98 83 8½ 6 58¼ 90 28 54 56 2½ 1¼ _GMP50 50,000 60 284T _GMP60 60,000 60 286T 102 90 9½ 6 63¼ 90 28 60 62 2½ 1¼ _GMP75 75,000 72 324T 90 w /o Filt House 73 _GMP90 90,000 84 324T 102 90 12 6 88 32 120 w/ _GMP100 100,000 84 324T Filt House 86¼ 86 3 1¼ NOTE: Dimensions subject to change. Certified prints available. Right-hand controls and access shown. For ANSI units and units with recirculating features contact factory for dimensions. 14

Principal Dimensions Sizes 3,000 60,000 CFM 1/8" CLEARANCE FOR INSULATION BETWEEN HOUSINGS. BOOT, SHUTTER & ACTUATOR MTR (OPTIONAL) SEE NOTE 8 12 S 60 1/8 30 1/8 12 G OFF OFF ON ACCESS DOOR INLET WEATHERHOOD (OPTIONAL) L DISCHARGE OPENING AIRFLOW ON FAN HEAT K SAFETY GUARD (WIRE MESH) STANDARD ITEM AT INTAKE OF UNIT. D INLET DAMPER BOOT (OPTIONAL) 2" CURB MOUNT CONST. (OPTIONAL) FAN HOUSE (HORIZONTAL DISCHARGE) T SIZE MALE N.P.T. FUEL GAS SUPPLY CONNECTION BURNER HOUSE ELECTRICAL SUPPLY FILTER HOUSE (OPTIONAL) U SIZE MALE N.P.T. GAS VENT LINE. CONNECTION (SUPPLIED ON IRI TYPE UNITS ONLY) CURB MOUNT CONST. (OPTIONAL) A M INSIDE HSG. OPENING N 10 F c PITCH B INSIDE HSG. A I R F L O W E C 1/2 DIA. HOLE H REQ.D. R DISCHARGE L OPENING FAN HOUSE (DOWNBLAST DISCHARGE) GENERAL PLAN VIEW DISCHARGE END (OPTIONAL SHUTTER NOT SHOWN) CURB MOUNT CONST. (OPTIONAL) AIRFLOW FAN HOUSE BURNER HOUSE FILTER HOUSE INLET WEATHER HOOD Principal Dimensions (Inches) Model GMC PLUMBING ELECTRICAL Model CFM Fan Max Motor Housing I.D. No. Range Size Frame A B C D E F G H K L M N R S T U _GMC3 3,000 15 182T _GMC5 5,000 15 184T 50 36 7½ 4 23¾ 18 30 12 13½ 16½ 22 3 /16 13 7 /8 16 5 /8 60 1 /8 ¾ ¾ _GMC7 7,000 20 213T _GMC10 10,000 20 215T 56 45 6½ 4 30½ 23 40 16 18½ 21 7 /16 29 13½ 20½ 60 1 /8 1 ¾ _GMC12 12,500 24 215T _GMC15 15,000 24 254T 69¼ 53 8½ 4 37 3 /16 27 15 /16 60 16 22 3 /8 26 7 /16 35 5 /8 16 13 /16 23 5 /8 60 1 /8 1½ ¾ _GMC20 20,000 30 254T _GMC25 25,000 30 256T 79 63 6½ 4 45 7 /16 34¼ 60 24 25 7 /8 32 3 /16 43 3 /8 17 13 /16 27 60 1 /8 2 1 _GMC30 30,000 36 284T _GMC35 35,000 36 286T 89 76 8 6 54 1 /8 40¾ 80 24 31½ 38 5 /8 52 1 /32 18½ 33¼ 90¼ 2 1 _GMC40 40,000 40 286T _GMC45 45,000 40 324T 98 83 9 6 60½ 45½ 90 24 34¼ 43 3 /16 58 3 /16 19 7 /8 36 9 /16 90¼ 2½ 1¼ _GMC50 50,000 44 324T _GMC60 60,000 44 326T 102 90 9 6 66 5 /8 50 1 /16 90 24 37 47¾ 64 5 /16 18 13 /16 39 1 /8 90¼ 2½ 1¼ _GMC75 75,000 54 449T _GMC90 90,000 54 449T See Page 16 for Dimensional Data _GMC100 100,000 54 449T NOTE: Dimensions subject to change. Certified prints available. Right-hand controls and left hand fan and burner house access shown. For ANSI units and units with recirculating features contact factory for dimensions. 15

Principal Dimensions Sizes 75,000 100,000 CFM DAMPER AND BOOT (OPTIONAL) BLOWER HOUSE CENTRIFUGAL BLOWER (DWDI) TOP HORIZONTAL DISCHARGE FILTER HOUSE (OPTIONAL) BURNER HOUSE WEATHER HOOD (OPTIONAL) 58 1/4 AIRFLOW ACCESS DOOR 110 12 CONTROL CABINET 46 7/8 8 55 64 3/4 26 78 3/8 160 END VIEW DISCHARGE 55 5/8 REF. * 72 30 GAS PIPING LOCATIONS 85 MAX. CFM Rating *Horizontal units with horizontal discharge 102" *Horizontal units with vertical discharge 110" Burner Data Standard Length Burner (Feet) Horizontal units with horizontal discharge 204 Horizontal units with vertical discharge 212 Output at Temp. Rise Inlet Gas Pressure Req d High Fire (1000 BTUH) at High Fire ( F) at High Fire MIN. STD. MAX. MIN. STD. MAX. MIN. (W.G.) MAX. 3,000 1 18 300 450 6 92 138 7 14 (W.G.) 5,000 1 1 /2 27 500 675 5 92 124 7 14 (W.G.) 7,000 2 36 700 900 5 92 118 7 14 (W.G.) 10,000 2 1 /2 45 1000 1125 5 92 103 14 5 psi 12,500 3 54 1250 1350 4 92 99 14 5 psi 15,000 3 1 /2 63 1500 1575 4 92 97 14 5 psi 20,000 4 1 /2 81 2000 2025 4 92 93 14 5 psi 25,000 5 1 /2 100 2500 2500 4 92 92 14 5 psi 30,000 7 126 3000 3150 4 92 97 14 5 psi 35,000 8 144 3500 3600 4 92 95 14 5 psi 40,000 9 162 4000 4050 4 92 93 14 5 psi 45,000 10 180 4500 4500 4 92 92 14 5 psi 50,000 11 200 5000 5000 4 92 92 14 5 psi 60,000 13 1 /2 243 6000 6075 4 92 93 24 5 psi 75,000 17 306 7500 7650 4 92 94 24 5 psi 90,000 22 396 9000 9900 4 92 101 24 5 psi 100,000 22 1 /2 405 10000 10125 4 92 93 24 5 psi 16

Vertical Installation Model GMC Model No. CFM Range D G S _GMC3 3,000 _GMC5 5,000 4 36 60 1 /8 _GMC7 7,000 _GMC10 10,000 4 36 60 1 /8 _GMC12 12,500 _GMC15 15,000 4 36 90 1 /4 _GMC20 20,000 _GMC25 25,000 4 48 90 1 /4 _GMC30 30,000 _GMC35 35,000 6 48 120 3 /8 _GMC40 40,000 _GMC45 45,000 6 48 120 3 /8 _GMC50 50,000 _GMC60 60,000 6 48 120 3 /8 _GMC75 75,000 _GMC90 90,000 CONTACT FACTORY _GMC100 100,000 Model GMP Model No. CFM Range D J B _GMP3 3,000 _GMP5 5,000 4 36 36 _GMP7 7,000 _GMP10 10,000 4 36 45 _GMP12 12,500 _GMP15 15,000 4 36 53 _GMP20 20,000 _GMP25 25,000 4 48 63 _GMP30 30,000 _GMP35 35,000 6 48 76 _GMP40 40,000 _GMP45 45,000 6 48 83 _GMP50 50,000 _GMP60 60,000 6 48 90 _GMP75 75,000 _GMP90 90,000 6 60 90 _GMP100 100,000 Principal dimensions are the same for vertical and horizontal units, see Pages 14 and 15. NOTE: Dimensions subject to change. Certified prints available. For units with recirculating features, contact factory for dimensions. 17

Installation Data Model GMP (Propeller Fan) Model No. Max. CFM Range Inlet Gas Pressure Range (Qty) & Size Filters Req d Fan Section Less Motor Disch. Boot, Shutter/Mtr. Burner Section Approx. Max. Weights Filter Section Inlet Guard Inlet Hood Turning Elbow _GMP3 3,000 7 W.G. to _GMP5 5,000 28 W.G. (6) 16 x 25 x 2 286 84 408 191 13 97 314 _GMP7 _GMP10 7,000 10,000 14 W.G. to 5 lbs. W.G. _GMP12 12,500 14 W.G. to _GMP15 15,000 5 lbs. W.G. (6) 20 x 25 x 2 (3) 16 x 25 x 2 (3) 20 x 25 x 2 (9) 16 x 25 x 2 363 128 805 250 20 119 604 473 155 966 294 26 174 801 _GMP20 _GMP25 20,000 25,000 14 W.G. to 5 lbs. W.G. _GMP30 30,000 14 W.G. to _GMP35 35,000 5 lbs. W.G. _GMP40 40,000 _GMP45 45,000 14 W.G. to 5 lbs. W.G. _GMP50 50,000 _GMP60 60,000 _GMP75 75,000 _GMP90 90,000 _GMP100 100,000 18 W.G. to 5 lbs. W. G. (16) 20 x 25 x 2 593 179 1066 346 33 229 1031 (10) 20 x 25 x 2 (15) 16 x 25 x 2 (24) 20 x 25 x 2 (6) 16 x 25 x 2 803 179 1417 430 41 306 1308 968 291 1669 512 49 358 1528 (40) 20 x 25 x 2 1113 347 1881 593 54 393 1755 (60) 20 x 25 x 2 1408 641 1881 1060 with transition 70 400 w/o filter house 700 w/filter house & trans. 1755 Model GMC (Centrifugal Fan) Sizes 3,000 100,000 CFM Model No. Max. CFM Range Inlet Gas Pressure Range (Qty) & Size Filters Req d Fan Section Less Motor Disch. Boot, Shutter/Mtr. Approx. Max. Weights Burner Section Filter Section Inlet Guard Inlet Hood _GMC3 3,000 7 W.G. to _GMC5 5,000 28 W.G. (6) 16 x 25 x 2 541 54 408 191 13 97 _GMC7 _GMC10 7,000 10,000 14 W.G. to 5 lbs. W.G. _GMC12 12,500 14 W.G. to _GMC15 15,000 5 lbs. W.G. (6) 20 x 25 x 2 (3) 16 x 25 x 2 (3) 20 x 25 x 2 (9) 16 x 25 x 2 893 77 805 250 20 119 1396 102 966 294 26 174 _GMC20 _GMC25 20,000 25,000 14 W.G. to 5 lbs. W.G. _GMC30 30,000 14 W.G. to _GMC35 35,000 5 lbs. W.G. _GMC40 40,000 _GMC45 45,000 14 W.G. to 5 lbs. W.G. _GMC50 50,000 _GMC60 60,000 _GMC75 75,000 _GMC90 90,000 _GMC100 100,000 18 W.G. to 5 lbs. W. G. (16) 20 x 25 x 2 1706 193 1066 346 33 229 (10) 20 x 25 x 2 (15) 16 x 25 x 2 (24) 20 x 25 x 2 (6) 16 x 25 x 2 2775 283 1417 430 41 306 3216 345 1669 512 49 358 (40) 20 x 25 x 2 3656 419 1881 593 54 393 (70) 20 x 25 x 2 6645 618 3955 1200 81 750 18

Series 78H & 78V Econo Gas Heaters Horizontal and Vertical Units Econo models are a low cost alternative to many air make-up problems faced in industry today. Units are ideal for supplying tempered make-up air or for total fresh air heating systems. Each unit is a complete air supply system in a self-contained package consisting of a fan, burner and controls. The assembly is designed for indoor or outdoor installation and is ready for connection to gas line and power source. The Series 78H econo unit is designed for horizontal installations; excellent for perimeter type heating of troublesome areas. The Series 78V econo is engineered for vertical type installations. The equipment can supply filtered or unfiltered make-up air or be used for a total fresh air heating system. The unit has a low silhouette, and installation is quite simple. Series 78H Series 78V Features: 7,100 to 23,500 CFM @ 1/4 external static pressure. Heating capacities of 950,000 to 2,900,000 BTU/HR available. Intake ventilator hood on Series 78V is constructed of 18 gauge internally reinforced, painted, galvannealed steel. Base is 14 gauge painted galvannealed steel. Front burner section is 10 gauge. Controls are mounted and wired. Burner is designed for natural gas or propane. Direct drive fan arrangement, motor in airstream. Motors are totally enclosed. Propellers are cast aluminum, airfoil design, 6-bladed fixed pitch design through 19,200 CFM units; 6-bladed, adjustable pitch assemblies are standard on 21,750 CFM units and up. Controls are mounted in a NEMA 4/12 enclosure, containng the disconnect switch, motor starter, control transformer, fuses and terminal strips, gas pressure switches and temperature controls, IRI control package is standard. Also meets FM requirements. NEMA 12 Remote Station. Econo units are furnished with left-hand control cabinet as shown in photograph above. Maxitrol 14 is standard. Maxitrol modulating temperature control. Temperature sensing elements mounted in airstream. High and low temperature limit control mounted within burner housing. Standard unit develops a maximum discharge temperature of 90 F. For optional discharge temperatures, contact factory. Motor operated shutter. Access door for servicing is standard. Econo models are available with filters. Airflow proving switch. Fireye flame safeguard. Fused disconnect switch High and low temperature controls. Mild weather thermostat. High and low gas pressure limits. Built to meet I.R.I. or F.M. Standards 19

Dimensions and Performance Principal Dimensions (Inches) Series 78H Model Net Installation No. A B C D E F G H Wt.* 78H-28DI4 28 7 /8 26 64 5 /16 66 3 /16 10 9 33 1 /8 37 1 /8 900 78H-44PJ5 45 26 59 13 /16 66 3 /16 10 6 50 1 /8 54 1 /8 1350 78H-48AL5 49 1 /8 26 59 1 /8 66 3 /16 10 7 1 /2 54 1 /8 58 1 /8 1750 NOTE: Dimensions are subject to change. Certified prints are available. *Wt. less filter house Rating Table Series 78H Basic Unit Filtered Unit Gas Pressure 0 Ext. S.P. /4 Ext. S.P. 0 Ext. S.P. /4 Ext. S.P. Req d Turn Model Motor Fan Fan No. Temp Temp Temp Temp Down No. BTU/HR HP RPM Size Type Blades CFM* Rise CFM Rise CFM Rise CFM Rise Min. Max. Ratio 78H-28DI4 950,000 1 1 /2 1160 28 D 6 8,200 107 F 7,400 118 F 7,900 111 F 7,100 123 F 14 (W.G.) 5 psi 8:1 78H-44PJ5 1,920,000 2 860 44 P 6 19,200 92 F 17,200 103 F 17,500 101 F 14,200 124 F 14 (W.G.) 5 psi 12:1 78H-48AL5 2,900,000 5 860 48 AA 6 28,000 95 F 23,500 113 F 26,950 99 F 22,550 118 F 14 (W.G.) 5 psi 7:1 *CFM shown is net flow at discharge and includes static pressure loss for burner and shutter. NOTE: Static pressure for calculated resistances external to the unit assembly. Principal Dimensions (Inches) Series 78V Nominal Net Model Hood Installation No. A B C D E F G H J K Size Wt.* 78V-28DI4 80 19 3 /4 28 7 /8 42 96 5 /8 52 11 /16 12 11 /16 2 1 /2 12 (12) 20 x 20 x 2 30 1600 (4) 10 x 20 x 2 78V-44PJ5 96 23 1 /4 45 58 1 /4 101 3 /8 53 3 /16 13 3 /16 3 18 (6) 16 x 20 x 2 42 2400 (8) 20 x 20 x 2 78V-48AL5 120 28 1/ 2 49 1/ 8 64 1/ 4 105 54 3/ 8 14 3/ 8 4 3/ 16 34 NOTE: Dimensions are subject to change. Certified prints are available. *Wt. less filters (14) 10 x 20 x 2 (20) 20 x 20 x 2 48 2900 Rating Table Series 78V Basic Unit Filtered Unit Gas Pressure 0 Ext. S.P. /4 Ext. S.P. 0 Ext. S.P. /4 Ext. S.P. Req d Turn Model Motor Fan Fan No. Temp Temp Temp Temp Down No. BTU/HR HP RPM Size Type Blades CFM* Rise CFM Rise CFM Rise CFM Rise Min. Max. Ratio 78V-28DI4 950,000 1 1 /2 1160 28 D 6 8,150 107 F 7,320 119 F 8,015 109 F 7,210 121 F 14 (W.G.) 5 psi 8:1 78V-44PJ5 1,920,000 2 860 44 P 6 18,950 93 F 15,500 114 F 18,360 96 F 14,910 118 F 14 (W.G.) 5 psi 12:1 78V-48AL5 2,900,000 5 860 48 AA 6 27,300 98 F 22,900 116 F 26,000 103 F 21,750 123 F 14 (W.G.) 5 psi 7:1 *CFM shown is net flow at discharge and includes static pressure loss for burner and shutter. NOTE: Static pressure for calculated resistances external to the unit assembly. 20

Series 79 Gas Fired Door Heater Heating has always been a problem in plants, warehouses, factories, etc., when overhead doors are frequently opened and closed. The rushing in of cold air when the doors are open chills personnel and lowers their working efficiency. Normal heating systems, such as unit heaters or duct systems, are not capable of handling this problem. Furthermore, an extra, sudden load is thrown on the heating system and as a result, heating costs rise substantially. This bothersome and costly problem can be solved by the Hartzell Automatic Door Heater which directs a blast of high velocity heated air toward the door opening. As a result of the turbulence created, the hot air mixes with the cold air, and the bite of the cold air is eliminated. The Hartzell unit works whenever the door is raised far enough to trip the switch. The fan starts, after a brief pre-purge time period, and safety function check, a high velocity stream of heated air is blasted into the cold entering air. Hartzell Automatic Door Heaters come equipped with Duct Axial propellers designed for high velocity at medium noise levels. These heaters can be mounted in either horizontal or vertical position or at any angle in between. Every Hartzell Automatic Door Heater is completely assembled and tested at the factory and is shipped ready for installation. Generally, the only installation requirement is connecting a unit to the electrical and fuel supply systems. Standard Features Electronic Flame Safeguard with LED Status Indicating Lights Magnetic Starter Control Transformer Ignition Transformer Sparktrode Interrupted Pilot Main Fuel Safety Valve High & Low Gas Pressure Switches* High Temperature Limit Switch Remote Station for Floor Mounting with Status Indicating Lights and Summer/Off/Winter Selector Switch Door Switch Air Flow Switch Inlet Guard 12 Ga. Hot Rolled Steel Housing Finish is Air-Dry Alkyd Enamel Applied over Phosphatized Steel Combination F.M. & I.R.I. Models Available through the HRS (Hartzell Rotating Stock) Program. * I.R.I. units only ** F.M. units only Hartzell Automatic Door Heaters are designed for heating open doorways only... they are not to be used for general-purpose plant heating. Built to meet I.R.I. or F.M. Standards 21

Design and Installation Options 30 30 SELF FORMED FLANGE 3 3/4 (BC) 5/16 DIA HOLE TYP 3 PL EQUALLY SPACED AIRFLOW O.D. 15 I.D. I.D. 7 1/2 Principal Dimensions Size A B C D E F G H 22 22 7 /8 26 1 /16 24 1 /2 20 32 11 /16 8 7 /16 21 1 /2 17 1 /2 24 24 7 /8 28 1 /16 26 5 /8 22 34 3 /16 9 15 /16 24 18 1 /2 NOTE: Specifications are subject to change. Certified prints are available. Rating Table Model Code No. Motor Fan Input Outlet Final Temp. Temp. Inlet Gas No. Size H.P. RPM CFM BTU Velocity 70 Ent. Air Rise Pressure 1 1 /2 1750 6,500 700,000 3,000 169 99 5 DH22 022 1 1 /2 1750 6,500 765,000 3,000 179 109 6 1 1 /2 1750 6,500 820,000 3,000 187 117 7 2 1750 7,900 865,000 3,000 171 101 6 DH24 024 2 1750 7,900 930,000 3,000 179 109 7 2 1750 7,900 990,000 3,000 186 116 8 NOTE: Based on Natural Gas Specific Gravity 0.6 1000 BTU per cu.ft. Shipping weights: DH22, 350 lbs.; DH 24, 400 lbs. 3 3/4 9/16 DIA HOLE TYP 4 PL 15 6 7/8 Automatic Door Heater Sizing Information Door No. of Input BTU Size Unit Units per Unit 12 x 12 DH22 1 750,000 12 x 14 DH22 1 820,000 12 x 16 DH24 1 930,000 14 x 16 DH22 2 700,000 16 x 18 DH24 2 865,000 16 x 20 DH24 2 930,000 For door sizes not covered, determine size and number of units on basis of approximately 5500 BTU/sq. ft. of door opening. NOTE: For proper application of Hartzell Automatic Door Heaters, the maximum square foot opening should not exceed 360 sq. ft. Overhead Door Mounted at a 45 or 30 angle, the Hartzell Automatic Door Heater directs a flow of hot air to the floor area just inside the doorway. The door switch turns on the heater when the door is opened. Roll Top Door Alternate vertical mounting of the Hartzell Automatic Door Heater may also be used with roll top or straight lift doors, directing a flow of hot air to the floor just inside the door opening. NOTE: It is recommended the door switch be mounted 24 from floor level. 14' 14' 12' Do Door Switch 22

Series 811 Shaft Heater Series 811 Standard Features All Hartzell Direct Gas Fired Shaft Heaters are provided with a control system as standard. This system includes the master control panel mounted in a NEMA 4/12 enclosure. It consists of the motor starter, disconnect switch, control transformer, terminal strips, gas pressure switches, airflow switch, flame management system, burner modulation control and temperature controls. Standard control package includes state-of-the-art, commercially available components such as Maxitrol air temperature control system and Honeywell Series 7800 flame safeguard system. Specific models may change depending on optional controls specified. BTU Range 7,000 to 100,000 CFM...works up to 1/2 external static pressure. Performance Primary functions To temper incoming down-cast ventilating air for comfort purposes. To raise the temperature of same above the freezing point of water; here the purpose is to avoid freezing of ground water seepage which otherwise would freeze and tend to partially block the shaft opening, reducing airflow. Advantages of Hartzell shaft heaters Mine personnel can work in comfortable temperatures. Volume of ventilation is maintained at desired levels. Because of direct firing, 100% of the BTU content of the fuel is utilized. 12-gauge steel housing reinforced with self-forming ribs for rigidity and flanges. Welded construction. Burner is designed for natural gas or propane. Belt drive arrangement, motor out of the airstream, is standard on units through 50,000 CFM. Drive bearings have extended grease tubes for servicing. 60,000 to 100,000 CFM units are belted, motor in airstream. Belts are oil, heat and static resistant. Propellers are cast aluminum, single piece, airfoil type, 3-, 6-, and 8-bladed on units through 50,000 CFM. 60,000 through 100,000 CFM units utilize 4- and 6-bladed adjustable pitch assemblies. Motors are TEFC. Special motors are available upon request. Special skids can be furnished, if required. Special control packages are available. Model CFM* Ext. SP** BTU/Hr 92 F Temp Rise Fan Size Fan RPM BHP No of Blades G71 0 1568 2.1 7,000 700,000 28 8 G72 1/4 1746 2.8 G101 0 1488 2.9 3 10,000 1,000,000 32 G102 1/4 1666 4.0 6 G151 0 1344 4.4 15,000 1,500,000 36 3 G152 1/4 1457 5.8 G201 0 1019 5.2 20,000 2,000,000 44 3 G202 1/4 1119 6.8 G251 0 998 7.4 25,000 2,500,000 48 3 G252 1/4 1100 9.8 G301 0 1079 9.2 30,000 3,000,000 48 3 G302 1/4 1157 11.5 G401 0 964 14.3 40,000 4,000,000 54 3 G402 1/4 1042 18.3 G501 0 880 16.6 50,000 5,000,000 60 3 G502 1/4 937 20.1 G601 0 790 19.9 60,000 6,000,000 72 6 G602 1/4 871 26.1 G751 0 830 25.1 70,000 7,500,000 72 6 G752 1/4 916 32.0 G901 0 570 26.5 90,000 9,000,000 85 6 G902 1/4 631 34.0 G1001 0 591 30.6 100,000 10,000,000 85 6 G1002 1/4 644 38.0 ACCESS DOOR AIRFLOW Principal Dimensions CONTROL CABINET Model A B F G7 33 1 8 37 1 8 96 G10 36 1 8 40 1 8 96 G15 42 1 8 46 1 8 96 G20 50 1 8 54 1 8 102 G25 54 1 8 58 1 8 102 G30 54 1 8 58 1 8 102 G40 60 1 8 64 1 8 105 G50 70 3 8 74 3 8 105 G60 84 88 144 G75 84 88 144 G90 96 100 144 G100 96 100 144 SQ. INSIDE SQ. 23

Series SFC Centrifugal Steam Heater Centrifugal steam air intake units are furnished with DWDI forward curve industrial blowers. The unit is a packaged design with controls mounted and wired. Features: 2,000 to 60,000 CFM works up to 2.5 external static pressure. Units sized 2,000 CFM through 30,000 CFM utilizes a DWDI single forward curve blower. Units sized 35,000 CFM through 60,000 CFM utilizes a DWDI twin forward curve blower. 16-gauge G-90 galvanized steel housing. Horizontal mount unit standard. Controls are mounted and wired in a NEMA 4/12 cabinet, containing disconnect switch, motor starter, control transformer, fuses and terminal strips, connections to the modulating steam valve and optional room thermostat are made at time of installation. NEMA 12 standard remote station shipped loose. Modulating temperature control. Temperature sensing element mounted in the airstream. Low temperature limit control mounted within coil housing. Motor operated inlet damper. Access door for servicing is standard. Easy coil removal, slides in and out of unit on rails. Belt drive arrangement, belts are oil, heat, and static resistant. Motors are totally enclosed fan cooled; other motors are available. Accessories such as filter boxes and inlet weather hoods are the same sizes as the Gas Forward Curve Unit Disconnect switch standard. Model SFC Single Performance Model Number CFM BTU/Hr @ 80 Temp Rise External Static Pressure 1 4 1 2 1 1 1 2 2 2 1 2 RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP ASFC3--21FC--2GLFC_3 2,000 174,000 838 3 4 915 3 4 1312 1 1 2 1458 1 1 2 1603 2 2018 2 ASFC3--31FC--3GLFC_3 3,000 261,000 694 1 768 1 1 2 895 1 1 2 1233 2 1339 3 1447 3 ASFC3--41FC--4GLFC_3 4,000 348,000 714 1 1 2 782 2 907 2 1019 3 1118 3 1209 5 ASFC3--51FC--5GLFC_3 5,000 435,000 744 2 806 2 925 3 1028 3 1129 5 1223 5 ASFC3-101FC-10GLFC_3 10,000 870,000 598 5 638 5 715 7 1 2 789 7 1 2 876 10 960 10 ASFC3-151FC-15GLFC_3 15,000 1,305,000 446 7 1 2 481 7 1 2 547 10 610 10 683 15 850 15 ASFC3-201FC-20GLFC_3 20,000 1,740,000 412 10 441 10 498 15 553 15 627 20 665 20 ASFC3-251FC-25GLFC_3 25,000 2,175,000 339 10 413 15 463 15 512 20 558 20 658 25 ASFC3-301FC-30GLFC_3 30,000 2,610,000 354 15 378 15 423 20 467 20 509 25 549 30 ASFC3-352FC-35GLFC_3 35,000 3,045,000 475 20 507 20 567 25 624 25 679 30 750 40 ASFC3-402FC-40GLFC_3 40,000 3,480,000 412 20 441 20 498 25 580 30 623 40 665 40 ASFC3-452FC-45GLFC_3 45,000 3,915,000 370 20 399 20 453 25 505 30 569 40 610 50 ASFC3-502FC-50GLFC_3 50,000 4,350,000 386 25 413 25 463 30 512 40 558 40 621 60 ASFC3-552FC-55GLFC_3 55,000 4,785,000 342 25 367 25 415 30 464 40 557 50 599 50 ASFC3-602FC-60GLFC_3 60,000 5,220,000 354 30 378 30 423 40 467 40 512 50 606 60 Notes: BTUH is based on 20 PSIG steam pressure and 80 temperature rise, contact factory for your exact requirements. CFM shown is net flow at discharge and includes internal static pressure loss for fan and coil section. When applying washable filters, add 1/8 Ext. SP When applying disposable filters, add 1/4 Ext. SP. BHP includes drive loses. Standard motor is TEFC, mounted in the airstream, with 1.15 service factor, specify motor HP rating accordingly. 24

Principal Dimensions INSIDE HOUSING O.D. DISCHARGE 8 DISCHARGE ANGLE 30 1/8 12 FILTER HOUSE (OPTIONAL) HOOD (OPTIONAL) SLIP FIT DISCHARGE ANGLE AIRFLOW AIRFLOW INSIDE HOUSING O.D. DISCHARGE ANGLE CONTROL CABINET INLET DAMPER HOUSE (OPTIONAL) INSIDE HOUSING O.D. DISCHARGE 8 DISCHARGE ANGLE 30 1/8 FILTER HOUSE (OPTIONAL) 12 HOOD (OPTIONAL) SLIP FIT DISCHARGE ANGLE AIRFLOW AIRFLOW INSIDE HOUSING O.D. DISCHARGE ANGLE CONTROL CABINET INLET DAMPER HOUSE (OPTIONAL) CFM Max. Housing ID Model Number C D J K L M N P R Range Motor Frame A B ASFC3--51FC--5GLFC_3 2 to 5,000 184T 41 32 2 74 7 3 16 19 18 7 8 11 1 16 19 18 7 8 ASFC3-101FC-10GLFC_3 10,000 215T 52 44 2 87 9 11 16 28 25 13 1 2 28 25 ASFC3-151FC-15GLFC_3 15,000 254T 11 9 16 34 1 2 31 1 2 18 3 4 34 1 2 31 1 2 69 58 2 108 57 ASFC3-201FC-20GLFC_3 20,000 256T 13 11 16 37 1 2 34 1 2 17 1 4 37 1 2 34 1 2 ASFC3-251FC-25GLFC_3 25,000 256T 15 3 16 40 37 22 40 37 81 66 2 108 57 ASFC3-301FC-30GLFC_3 30,000 284T 13 3 16 46 1 4 40 1 4 20 3 8 46 1 4 40 1 4 ASFC3-352FC-35GLFC_3 35,000 286T 12 1 16 34 1 2 87 3 4 22 1 8 34 1 2 87 3 4 132 58 2 108 57 ASFC3-402FC-40GLFC_3 40,000 324T 15 1 16 37 1 2 96 1 4 17 7 8 37 1 2 96 1 4 ASFC3-452FC-45GLFC_3 45,000 324T 148 66 2 108 57 16 9 16 40 103 3 4 22 1 8 40 103 3 4 ASFC3-502FC-45GLFC_3 50,000 ASFC3-552FC-55GLFC_3 55,000 326T 162 66 2 108 57 14 1 2 46 1 4 112 3 4 24 5 8 46 1 4 112 3 4 ASFC3-602FC-60GLFC_3 60,000 365T 36 1 2 CFM Fan Heating Filter Inlet Quantity & Size Model Number Range Section (Lbs.) Section (Lbs.) Box (Lbs.) Hood (Lbs.) Filters Req d ASFC3--51FC--5GLFC_3 2-5,000 679 195 107 (4) 20 x 25 x 2 ASFC3-101FC-10GLFC_3 10,000 1,035 255 131 (6) 16 x 25 x 2 (3) 20 x 25 x 2 ASFC3-151FC-15GLFC_3 15,000 1,252 (12) 16 x 25 x 2 345 252 ASFC3-201FC-20GLFC_3 20,000 1,643 (4) 20 x 25 x 2 ASFC3-251FC-25GLFC_3 25,000 1,804 ASFC3-301FC-30GLFC_3 30,000 2,296 401 337 (20) 20 x 25 x 2 ASFC3-352FC-35GLFC_3 35,000 1,186 1,198 (8) 16 x 25 x 2 490 394 ASFC3-402FC-40GLFC_3 40,000 1,531 1,312 (16) 25 x 20 x 2 ASFC3-452FC-45GLFC_3 45,000 1,828 1,461 (15) 16 x 25 x 2 590 432 ASFC3-502FC-50GLFC_3 50,000 1,828 1,481 (25) 20 x 25 x2 ASFC3-552FC-55GLFC_3 55,000 2,273 1,497 ASFC3-602FC-60GLFC_3 60,000 2,273 1,497 625 472 (40) 20 x 25 x 2 25

Series SMP Propeller Steam Unit Type A (shown) Types A and B (Horizontal Intake Unit) Hartzell propeller steam air make-up units are designed around the proven 3-bladed, lo-noise airfoil propeller, providing full efficiency at slow speeds without excessive noise. 50,000-60,000 CFM units utilize an adjustable pitch, 6-bladed airfoil design assembly with belted construction, totally enclosed motor in airstream. The unit is a packaged design with controls mounted and wired. Features: 6,000 to 60,000 CFM...works up to 1/4 external static pressure. 12-gauge steel housing reinforced with self-forming ribs for rigidity and flanges. Welded construction. Controls are mounted and wired. Easy coil removal...slide in and out of the unit on rails. Belt drive arrangement, motor out of airstream. Drive bearings have extended grease tubes for servicing. Belts are oil, heat and static resistant. Motors are open end, protected. Totally enclosed fan cooled and other special motors are available. Belt guards are standard. NEMA 12 remote control station with pilot lights. Controls are mounted in a NEMA 4/12 panel and enclosure, containing the motor starter, control transformer, fuses, and terminal strips. (Connections to the modulating steam valve and optional room thermostat are made at the time of installation). Modulating temperature control. Temperature sensing element mounted in airstream. Low temperature limit control mounted within coil housing. Motor operated inlet damper. Access door for servicing is standard. Filter box on Type B unit can be located on discharge or intake side. Coils are non-freeze type protected by a low temperature thermostat. Accessories see Pages 38 and 39. Types C and D (Vertical Intake Unit) The Hartzell steam air make-up units, roof intake design, combine a hooded ventilator for fresh air intake with a steam heating system. The result is heated air make-up capability where vertical installation is required. The roof intake hood utilizes the proven lo-noise, 3-bladed cast aluminum propeller in a hood, providing complete protection from the elements. The heating section hangs beneath the roofline. Features: 6,000 to 45,000 CFM...works up to 1/4 external static pressure. Roof hood is constructed of 20-gauge galvanized steel. Heating section constructed of 12-gauge steel, housing is reinforced with self-forming ribs for rigidity and flanges. Welded construction. Controls are mounted and wired. Easy coil removal...slide in and out of the unit on rails. Belted arrangement, motor in the airstream. Drive bearings have extended grease tubes for servicing. Belts are oil, heat and static resistant. Motors are totally enclosed. Special motors are available upon request. NEMA 12 remote control station with pilot light. Controls are mounted in a NEMA 4/12 panel and enclosure containing the motor starter, control transformer, fuses, and terminal strips. Wiring to the fan motor must be done at installation. (Connections to the modulating steam valve and optional room thermostat are made at the time of installation). Fused disconnect switch standard. Modulating temperature control. Temperature sensing element mounted in airstream. Low temperature limit control mounted within coil housing. Motor operated inlet damper. Access door for servicing is standard. Filter box on Type C & D units can be located on discharge or intake side. Coils are non-freeze type protected by a low temperature ther mostat. Accessories see Pages 38 and 39. 26 1 (800)

Principal Dimensions Type A and B UNIT FAN SHAFT MODEL SIZE (CFM) HOUSING SIZE AT HUB AT BEARING A B C D E F SMP6 6,000 12GA. 28 1 1 33 1 /4 37 1 /4 32 1 /2 55 2 42 SMP8 8,000 12GA. 32 1 3 /16 1 3 /16 39 1 /2 43 1 /2 35 3 /4 55 2 42 SMP10 10,000 12GA. 32 1 3 /16 1 3 /16 39 1 /2 43 1 /2 35 3 /4 55 2 1 /2 42 SMP13 12,500 12GA. 36 1 3 /16 1 3 /16 50 1 /4 54 1 /4 38 1 /4 55 2 42 SMP15 15,000 12GA. 36 1 3 /16 1 3 /16 50 1 /4 54 1 /4 38 1 /4 55 2 1 /2 42 SMP20 20,000 12GA. 44 1 11 /16 1 11 /16 69 1 /4 73 1 /4 42 1 /2 55 2 42 SMP25 25,000 12GA. 48 1 11 /16 1 11 /16 69 1 /4 73 1 /4 42 1 /2 55 2 1 /2 42 SMP30 30,000 12GA. 48 1 11 /16 1 11 /16 69 1 /4 73 1 /4 42 1 /2 55 2 1 /2 42 SMP35 35,000 12GA. 54 1 11 /16 1 11 /16 84 1 /4 88 1 /4 40 3 /4 55 2 1 /2 42 SMP40 40,000 12GA. 60 1 15 /16 1 15 /16 84 1 /4 88 1 /4 40 3 /4 55 2 1 /2 42 SMP45 45,000 12GA. 60 1 15 /16 1 15 /16 84 1 /4 88 1 /4 40 3 /4 55 2 1 /2 42 SMP50 50,000 12GA. 72 1 15 /16 1 15 /16 96 100 63 3 /4 78 2 1 /2 42 SMP60 60,000 12GA. 72 1 15 /16 1 15 /16 96 100 63 3 /4 78 2 1 /2 42 Note: Specifications are subject to change. Certified prints are available. Type A Basic unit less filters Type B Basic unit with filters Type C and D UNIT HOOD SIZE FAN SHAFT NOM. MODEL (CFM) HOUSING SIZE AT HUB AT BEARING A B C D E F G H SIZE SMP6 6,000 12GA. 30 1 1 33 1 /4 37 1 /4 80 30 2 42 55 5 /8 35 1 /4 30 SMP8 8,000 12GA. 30 1 3 /16 1 3 /16 39 1 /2 43 1 /2 80 30 2 42 55 5 /8 35 1 /4 30 SMP10 10,000 12GA. 30 1 3 /16 1 3 /16 39 1 /2 43 1 /2 80 30 2 1 /2 42 55 5 /8 35 1 /4 30 SMP13 12,500 12GA. 36 1 3 /16 1 3 /16 50 1 /4 54 1 /4 90 30 2 42 57 7 /8 42 1 /4 36 SMP15 15,000 12GA. 36 1 3 /16 1 3 /16 50 1 /4 54 1 /4 90 30 2 1 /2 42 57 7 /8 42 1 /4 36 SMP20 20,000 12GA. 48 1 3 /16 1 3 /16 69 1 /4 73 1 /4 120 30 2 42 72 1 /2 54 1 /4 48 SMP25 25,000 12GA. 48 1 7 /16 1 7 /16 69 1 /4 73 1 /4 120 30 2 1 /2 42 72 1 /2 54 1 /4 48 SMP30 30,000 12GA. 48 1 11 /16 1 11 /16 69 1 /4 73 1 /4 120 30 2 1 /2 42 72 1 /2 54 1 /4 48 SMP35 35,000 12GA. 54 1 11 /16 1 11 /16 84 1 /4 88 1 /4 140 30 2 1 /2 42 77 3 /8 60 1 /4 54 SMP40 40,000 12GA. 60 1 15 /16 1 15 /16 84 1 /4 88 1 /4 150 5 /8 30 2 1 /2 42 80 3 /4 66 1 /4 60 SMP45 45,000 12GA. 60 1 15 /16 1 15 /16 84 1 /4 88 1 /4 150 5 /8 30 2 1 /2 42 80 3 /4 66 1 /4 60 Note: Specifications are subject to change. Certified prints are available. Type C Basic unit and roof hood less filters Type D Basic unit and roof hood less filters 27

Rating Tables Type A UNIT SIZE EXT. 5 PSIG 0 F EAT FAN FAN MTR. (CFM*) SP** BTU/HR RISE SIZE RPM HP 6,000 0 536,280 82 28 1235 1 6,000 1/4 536,280 82 28 1462 1 1 /2 8,000 0 741,200 85 32 1071 1 1 /2 8,000 1/4 741,200 85 32 1307 2 10,000 0 828,400 76 32 1300 2 10,000 1/4 828,400 76 32 1491 3 12,500 0 1,199,000 88 36 1000 2 12,500 1/4 1,199,000 88 36 1142 3 15,000 0 1,324,350 81 36 1184 3 15,000 1/4 1,324,350 81 36 1296 5 20,000 0 2,071,000 95 44 784 3 20,000 1/4 2,071,000 95 44 900 5 25,000 0 2,398,000 88 48 810 5 25,000 1/4 2,398,000 88 48 905 5 30,000 0 2,616,000 80 48 959 7 1 /2 30,000 1/4 2,616,000 80 48 1042 10 35,000 0 3,433,500 90 54 734 7 1 /2 35,000 1/4 3,433,500 90 54 816 10 40,000 0 3,749,600 86 60 670 7 1 /2 40,000 1/4 3,749,600 86 60 740 10 45,000 0 3,973,050 81 60 740 7 1 /2 45,000 1/4 3,973,050 81 60 810 15 50,000 0 4,905,000 90 72 689 @11.8 7 1 /2 50,000 1 /4 4,905,000 90 72 60,000 0 5,362,800 82 72 60,000 1/4 5,362,800 82 72 689 @14.4 689 @16.5 689 @19.8 15 * CFM shown is net flow at discharge and includes static pressure loss for coil and shutter. ** Static pressure for calculated resistances external to the unit assembly Series SMP 50,000 and 60,000 CFM units; 20 psi minimum steam main pressure.. Type C UNIT SIZE EXT. 5 PSIG 0 F EAT FAN FAN MTR. (CFM*) SP** BTU/HR RISE SIZE RPM HP 6,000 0 536,280 82 30 1126 1 6,000 1/4 536,280 82 30 1342 2 8,000 0 741,200 85 30 1143 1 1 /2 8,000 1/4 741,200 85 30 1378 2 10,000 0 828,400 76 30 1512 3 10,000 1/4 828,400 76 30 1713 5 12,500 0 1,199,000 88 36 1023 2 12,500 1/4 1,199,000 88 36 1159 3 15,000 0 1,324,350 81 36 1260 5 15,000 1/4 1,324,350 81 36 1373 5 20,000 0 2,071,000 95 48 672 3 20,000 1/4 2,071,000 95 48 788 5 25,000 0 2,398,000 88 48 851 5 25,000 1/4 2,398,000 88 48 943 7 1 /2 30,000 0 2,616,000 80 48 1027 10 30,000 1/4 2,616,000 80 48 1103 10 35,000 0 3,433,500 90 54 761 7 1 /2 35,000 1/4 3,433,500 90 54 839 10 40,000 0 3,749,600 86 60 687 10 40,000 1/4 3,749,600 86 60 759 15 45,000 0 3,973,050 81 60 784 15 45,000 1/4 3,973,050 81 60 847 15 * CFM shown is net flow at discharge and includes static pressure loss for roof hood, coil, and shutter. ** Static pressure for calculated resistances external to the unit assembly. Series SMP 50,000 and 60,000 CFM units; 20 psi minimum steam main pressure. 10 15 Type B UNIT SIZE EXT. 5 PSIG 0 F EAT FAN FAN MTR. (CFM*) SP** BTU/HR RISE SIZE RPM HP 6,000 0 536,280 82 28 1375 1 1 /2 6,000 1/4 536,280 82 28 1590 2 8,000 0 741,200 85 32 1177 1 1 /2 8,000 1/4 741,200 85 32 1385 3 10,000 0 828,400 76 32 1385 3 10,000 1/4 828,400 76 32 1622 5 12,500 0 1,199,000 88 36 1050 2 12,500 1/4 1,199,000 88 36 1196 3 15,000 0 1,324,350 81 36 1242 5 15,000 1/4 1,324,350 81 36 1364 5 20,000 0 2,071,000 95 44 801 3 20,000 1/4 2,071,000 95 44 930 5 25,000 0 2,398,000 88 48 833 5 25,000 1/4 2,398,000 88 48 940 7 1 /2 30,000 0 2,616,000 80 48 1002 7 1 /2 30,000 1/4 2,616,000 80 48 1108 10 35,000 0 3,433,500 90 54 757 7 1 /2 35,000 1/4 3,433,500 90 54 845 15 40,000 0 3,749,600 86 60 691 7 1 /2 40,000 1/4 3,749,600 86 60 805 10 45,000 0 3,973,050 81 60 775 15 45,000 1/4 3,973,050 81 60 840 15 50,000 0 4,905,000 90 72 689 @12.4 7 /2 1 50,000 1/4 4,905,000 90 72 689 @15.6 10 60,000 0 5,362,800 82 72 689 @17.8 15 60,000 1/4 5,362,800 82 72 689 @21.8 15 * CFM shown is net flow at discharge and includes static pressure loss for coil, shutter and filter house. ** Static pressure for calculated resistances external to the unit assembly. Series SMP 50,000 and 60,000 CFM units; 20 psi minimum steam main pressure. Type D UNIT SIZE EXT. 5 PSIG 0 F EAT FAN FAN MTR. (CFM*) SP** BTU/HR RISE SIZE RPM HP 6,000 0 536,280 82 30 1174 1 1 /2 6,000 1/4 536,280 82 30 1377 2 8,000 0 741,200 85 30 1185 1 1 /2 8,000 1/4 741,200 85 30 1428 2 10,000 0 828,400 76 30 1575 3 10,000 1/4 828,400 76 30 1795 5 12,500 0 1,199,000 88 36 1050 3 12,500 1/4 1,199,000 88 36 1185 5 15,000 0 1,324,350 81 36 1289 5 15,000 1/4 1,324,350 81 36 1402 7 1 /2 20,000 0 2,071,000 95 48 686 3 20,000 1/4 2,071,000 95 48 804 5 25,000 0 2,398,000 88 48 870 5 25,000 1/4 2,398,000 88 48 963 7 1 /2 30,000 0 2,616,000 80 48 1047 10 30,000 1/4 2,616,000 80 48 1123 15 35,000 0 3,433,500 90 54 773 7 1 /2 35,000 1/4 3,433,500 90 54 853 10 40,000 0 3,749,600 86 60 702 10 40,000 1/4 3,749,600 86 60 774 15 45,000 0 3,973,050 81 60 800 15 45,000 1/4 3,973,050 81 60 864 20 * CFM shown is net flow at discharge and includes static pressure loss for roof hood, coil, shutter and filter house. ** Static pressure for calculated resistances external to the unit assembly. Series SMP 50,000 and 60,000 CFM units; 20 psi minimum steam main pressure. 28

Coil and Filter Data UNIT SIZE COILS FILTERS (CFM) No. Total Face Area Number & Size Total Face Area 6,000 1 5.5 SQ. FT. (6) 25 x 16 x 2 16.68 SQ. FT. 8,000 1 7.7 SQ. FT. (6) 25 x 20 x 2 20.82 SQ. FT. 10,000 1 7.7 SQ. FT. (6) 25 x 20 x 2 20.82 SQ. FT. 12,500 1 13.1 SQ. FT. (10) 25 x 20 x 2 34.70 SQ. FT. 15,000 1 13.1 SQ. FT. (10) 25 x 20 x 2 34.70 SQ. FT. 20,000 2 25.6 SQ. FT. (14) 25 x 20 x 2 + (7) 20 x 20 x 2 68.04 SQ. FT. 25,000 2 25.6 SQ. FT. (14) 25 x 20 x 2 + (7) 20 x 20 x 2 68.04 SQ. FT. 30,000 2 25.6 SQ. FT. (14) 25 x 20 x 2 + (7) 20 x 20 x 2 68.04 SQ. FT. 35,000 2 39.4 SQ. FT. (27) 20 x 20 x 2 + (9) 25 x 20 x 2 106.29 SQ. FT. 40,000 2 39.4 SQ. FT. (27) 20 x 20 x 2 + (9) 25 x 20 x 2 106.29 SQ. FT. 45,000 2 39.4 SQ. FT. (27) 20 x 20 x 2 + (9) 25 x 20 x 2 106.29 SQ. FT. 50,000 2 54.8 SQ. FT. (54) 25 x 16 x 2 150.00 SQ. FT. 60,000 2 54.8 SQ. FT. (54) 25 x 16 x 2 150.00 SQ. FT. Installation Weights For Types A & B Only For Types A, B, C & D Type D Diffusers UNIT Type A Type B Type C Roof-Hood Turning Weather SIZE (CFM) Basic Unit W/Filters Roof Hood W/Filters Elbow Hood 2-Way 4-Way 6,000 869 1174 1227 1562 290 165 67 134 8,000 1045 1445 1408 1803 320 180 79 158 10,000 1056 1456 1414 1814 320 180 79 158 12,500 1287 1787 1713 2213 360 195 101 202 15,000 1353 1853 1779 2279 360 195 101 202 20,000 1958 2508 2660 3210 940 280 139 278 25,000 2079 2779 2781 3502 940 280 139 278 30,000 2245 2945 2947 3707 940 280 139 278 35,000 2570 3270 3460 4160 1350 360 169 338 40,000 2629 3504 3621 4498 1350 360 169 338 45,000 2728 3603 3720 4595 1350 360 169 338 50,000 3547 4684 1600 440 60,000 3683 4864 1600 440 Notes: Weights are in lbs. for all units and include the following: TYPE A Basic unit only. TYPE B Basic unit and filter house. TYPE C Basic unit and roof hood. TYPE D Basic unit, roof hood and filter house. 29

Series SMC Centrifugal Steam Unit Types A and B (Horizontal Intake Unit) Centrifugal steam air intake units are furnished with DWDI fans with heavy-duty industrial forward-curved wheels. The result is efficient performance for industrial duct distribution systems where high static pressure capabilities are required. The unit is a packaged design with the controls mounted and wired. Features: 8,000 to 45,000 CFM...works up to 1 1 2 external static pressure. 12-gauge steel housing reinforced with self-forming ribs for rigidity and flanges. Welded construction. Horizontal discharge is standard. Can be placed in vertical up or down position if specified. Controls are mounted and wired. Easy coil removal...slide in and out of the unit on rails. Belt drive arrangement, motor out of airstream. Drive bearings have extended grease tubes for servicing. Belts are oil, heat and static resistant. Motors are open end, protected. Totally enclosed fan cooled and other special motors are available. Belt guards are standard. NEMA 12 remote control station with pilot lights. Controls are mounted in a NEMA 4/12 panel end enclosure, containing the motor starter, control transformer, fuses and terminal strips. Wiring to the fan motor must be done at installation. (Connections to the modulating steam valve and optional room thermostat are made at the time of installation). Principal Dimensions (Type A and B) Note: Specifications are subject to change. Certified prints are available. Type A Basic unit less filters Type B Basic unit with filters Type A shown Fused disconnect switch standard. Modulating temperature control. Temperature sensing element mounted in airstream. Low temperature limit control mounted within coil housing. Motor operated inlet damper. Access door for servicing is standard. Coils are non-freeze type protected by a low temperature thermostat. Accessories see Pages 38 and 39. UNIT SIZE DWDI WHLS. GAUGES SHAFT MODEL (CFM) HOUSING HSGS WHLS AT HUB AT BEARING A B C D E F H J K L SMC8 8,000 12GA. 16GA. 18GA. 3 1 3 /16 42 1 /4 46 1 /4 42 1 /4 22 19 42 30 30 18 2 SMC10 10,000 12GA. 16GA. 18GA. 3 1 3 /16 42 1 /4 46 1 /4 42 1 /4 22 19 42 30 30 18 2 1 /2 SMC13 12,500 12GA. 16GA. 16GA. 3 1 3 /16 42 1 /4 46 1 /4 84 27 3 /8 27 3 /8 42 30 30 18 2 1 /2 SMC15 15,000 12GA. 16GA. 18GA. 3 1 3 /16 42 1 /4 46 1 /4 84 62 19 42 30 30 18 2 1 /2 SMC20 20,000 12GA. 16GA. 18GA. 4 1 7 /16 48 52 102 62 19 48 30 30 18 2 1 /2 SMC25 25,000 12GA. 16GA. 16GA. 4 1 7 /16 48 52 102 70 1 /2 27 1 /4 48 30 30 18 2 1 /2 SMC30 30,000 12GA. 16GA. 16GA. 4 1 7 /16 48 52 102 70 1 /2 27 1 /4 48 30 30 18 2 1 /2 SMC35 35,000 12GA. 16GA. 16GA. 4 1 /2 1 15 /16 62 66 138 96 36 3 /4 62 30 30 18 2 1 /2 SMC40 40,000 12GA. 16GA. 16GA. 4 1 /2 1 15 /16 62 66 138 96 36 3 /4 62 30 30 18 2 1 /2 SMC45 45,000 12GA. 16GA. 16GA. 4 1 /2 1 15 /16 62 66 138 96 36 3 /4 62 30 30 18 2 1 /2 Note: Top horizontal discharge standard. If bottom discharge required, specify. 30

Rating Tables Type A - less filters UNIT SIZE (CFM*) OUTLET VELOCITY 5 PSIG - 0 F EAT WHEEL NO. 0 EXT. SP** 1 2 EXT. SP** 1 EXT. SP** 1 1 2 EXT. SP** BTU/HR RISE DIA. WHEELS RPM HP RPM HP RPM HP RPM HP 8,000 2765 741,200 85 18 1 520 3 642 3 745 5 837 5 10,000 3445 828,400 76 18 1 642 5 750 5 832 7 1 2 925 7 1 2 12,500 2420 1,212,625 89 22 1 416 5 500 5 578 7 1 2 662 7 1 2 15,000 1835 1,340,700 82 18 2 508 5 628 7 1 2 742 7 1 2 843 10 20,000 2445 2,136,400 98 18 2 552 7 1 2 667 10 773 10 852 15 25,000 1875 2,452,500 90 22 2 418 7 1 2 500 10 582 15 658 15 30,000 2245 2,681,400 82 22 2 496 15 568 15 638 20 703 20 35,000 1430 3,357,200 88 27 1 2 2 294 7 1 2 367 10 431 15 498 20 40,000 1635 3,575,200 82 27 1 2 2 328 15 400 15 461 20 518 25 45,000 1835 3,825,900 78 27 1 2 2 356 15 423 20 481 25 532 30 **CFM shown is net flow at discharge and includes static pressure loss for coil and shutter. **Static pressure for calculated resistances external to the unit assembly. Type B - with filters UNIT SIZE OUTLET 5 PSIG - 0 F EAT WHEEL NO. 0 EXT. SP** 1 2 EXT. SP** 1 EXT. SP** 1 1 2 EXT. SP** (CFM*) VELOCITY BTU/HR RISE DIA. WHEELS RPM HP RPM HP RPM HP RPM HP 8,000 2765 741,200 85 18 1 542 3 647 3 752 5 852 5 10,000 3445 828,400 76 18 1 662 5 765 5 855 7 1 2 933 7 1 2 12,500 2420 1,212,625 89 22 1 432 5 507 5 592 7 1 2 673 7 1 2 15,000 1835 1,340,700 82 18 2 542 5 653 7 1 2 755 7 1 2 853 10 20,000 2445 2,136,400 98 18 2 571 7 1 2 678 10 788 10 872 15 25,000 1875 2,452,500 90 22 2 444 7 1 2 512 10 596 15 677 15 30,000 2245 2,681,400 82 22 2 508 15 586 15 652 20 721 20 35,000 1430 3,357,200 88 27 1 2 2 300 7 1 2 378 10 442 15 505 15 40,000 1635 3,575,200 82 27 1 2 2 339 15 408 20 470 20 526 25 45,000 1835 3,825,900 78 27 1 2 2 371 15 433 20 493 25 544 30 **CFM shown is net flow at discharge and includes static pressure loss for coil and shutter. **Static pressure for calculated resistances external to the unit assembly. Series SMC 25,000 CFM unit only; 15 psi minimum steam main pressure. Series SMC 30,000 thru 45,000 CFM units only: 20 psi minimum steam main pressure. Coil and Filter Data - Installation Weights UNIT SIZE COILS FILTERS (CFM) No. Total Face Area Number & Size Total Face Area 8,000 1 7.7 SQ. FT. (8) 25 x 20 x 2 27.76 SQ. FT. 10,000 1 7.7 SQ. FT. (8) 25 x 20 x 2 27.76 SQ. FT. 12,500 1 13.4 SQ. FT. (12) 25 x 20 x 2 41.64 SQ. FT. 15,000 1 13.4 SQ. FT. (12) 25 x 20 x 2 41.64 SQ. FT. 20,000 1 27.4 SQ. FT. (20) 25 x 20 x 2 69.40 SQ. FT. 25,000 1 27.4 SQ. FT. (20) 25 x 20 x 2 69.40 SQ. FT. 30,000 1 27.4 SQ. FT. (20) 25 x 20 x 2 69.40 SQ. FT. 35,000 2 36.8 SQ. FT. (35) 25 x 20 x 2 121.45 SQ. FT. 40,000 2 36.8 SQ. FT. (35) 25 x 20 x 2 121.45 SQ. FT. 45,000 2 36.8 SQ. FT. (35) 25 x 20 x 2 121.45 SQ. FT. UNIT Type A Type B SIZE Fan Basic Basic Units Weather (CFM) Size Units W/Filters Hood 8,000 18 1256 1656 195 10,000 18 1288 1688 195 12,500 22 1503 2003 290 15,000 18 1516 2016 290 20,000 18 2010 2510 290 25,000 22 2362 2987 360 30,000 22 2468 3093 360 35,000 27 1 /2 3167 4267 540 40,000 27 1 /2 3273 4373 540 45,000 27 1 /2 3290 4390 540 Notes: Weights are in lbs. for all units and include the following: TYPE A Basic unit only. TYPE B Basic unit and filter house. 31

Series SAH and Series SCH Face and Bypass Assembly Series SAH Horizontal Axial Flow (shown) Series SCH Horizontal Centrifugal Face and bypass units provide better temperature modulation in marginal, as well as, extended cold weather by varying the airflow through the coil by means of proportioned face and bypass dampers. The damper enclosure is designed with a plenum chamber containing guide vanes providing for proper mixing of air. The result is modulating temperature control with full steam pressure at all times reducing the problem of coil freeze-up. The face and bypass section is available in two designs utilizing a Hartzell duct axial fan (Series SAH) or a DWDI forward curve centrifugal fan (Series SCH). Both are designed as packaged units with controls mounted and wired. Features: Series SAH Axial Units 8,000 to 45,000 CFM...works up to 1 external static pressure. Utilizes the Hartzell 6-bladed duct axial fan. Vane section available for higher static pressures up to 3 external. Series SCH Centrifugal Units 8,000 to 45,000 CFM...works up to 1 1 2 external static pressure. Utilizes a DWDI heavy-duty industrial forward curve wheel. General Features: 12-gauge steel housing reinforced with self-forming ribs for rigidity and flanges. Welded construction. Horizontal discharge is standard. Can be built for vertical up or down position. Easy coil removal...slide in and out of the unit on rails. Belt drive arrangement, motor out of the airstream. Drive bearings have extended grease tubes for servicing. Belts are oil, heat and static resistant. Belt guards are standard. NEMA 12 remote control station with pilot lights. Controls are mounted in a NEMA 4/12 panel and enclosure containing the motor starter, control transformer, fuses, and terminal strips. Wiring to the fan motor must be done at installation. (Connections to the steam valve and optional room thermostat are made at the time of installation). Modulating temperature control. Temperature sensing element mounted in the airstream. Low temperature limit control mounted within coil housing. Unit can be used in both indoor and outdoor installations. Steam and return lines should be insulated in a common housing to prevent freezing in outdoor installations. Motor operated dampers. Access door for servicing is standard. Filter Box optional. Specify Type A (less filters) or Type B (with filters). Can be located on inlet only. Accessories see Pages 38 and 39. 32

Principal Dimensions Series SAH UNIT SIZE FAN SHAFT MODEL (CFM) HOUSING SIZE AT HUB AT BEARING A B C D E F H J K L M N T SAH8 8,000 12 GA. 32 1 7 /16 1 7 /16 33 36 1 /8 34 7 /8 23 1 /8 15 34 64 7/16 6 42 1 /4 42 1 /4 62 1 /4 2 SAH10 10,000 12 GA. 32 1 7 /16 1 7 /16 33 36 1 /8 34 7 /8 23 1 /8 15 34 64 7/16 6 42 1 /4 42 1 /4 62 1 /4 2 SAH13 12,500 12 GA. 36 1 11 /16 1 11 /16 37 40 1 /8 38 7 /8 23 1 /8 16 34 58 7/16 6 84 42 1 /4 58 1 /4 2 SAH15 15,000 12 GA. 36 1 11 /16 1 11 /16 37 40 1 /8 38 7 /8 23 1 /8 16 34 58 7/16 6 84 42 1 /4 58 1 /4 2 SAH20 20,000 12 GA. 44 1 15 /16 1 15 /16 45 48 1 /4 47 1 /8 26 19 42 70 7/16 12 102 48 72 2 SAH25 25,000 12 GA. 48 1 15 /16 1 15 /16 49 1 /8 53 3 /8 51 5 /8 26 22 42 70 7/16 12 102 48 72 2 SAH30 30,000 12 GA. 48 1 15 /16 1 15 /16 49 1 /8 53 3 /8 51 5 /8 26 22 42 70 7/16 12 102 48 72 2 SAH35 35,000 12 GA. 48 1 15 /16 1 15 /16 49 1 /8 53 3 /8 51 5 /8 33 22 42 76 7/16 12 138 62 89 2 SAH40 40,000 12 GA. 54 2 7 /16 2 7 /16 55 3 /8 59 5 /8 57 5 /8 33 23 42 76 7/16 12 138 62 89 2 SAH45 45,000 12 GA. 54 2 7 /16 2 7 /16 55 3 /8 59 5 /8 57 5 /8 33 23 42 76 7/16 12 138 62 89 2 Note: Specifications are subject to change. Certified prints are available. Series SCH UNIT SIZE DWDI WHLS GAUGES SHAFT MODEL (CFM) HOUSING NO. SIZE HSGS WHLS AT HUB AT BRG A B C D E F G H J K L R T SCH8 8,000 12 GA. 1 18 16 18 3 1 3 /16 42 1 /4 62 1 /4 22 42 1 /4 19 18 7 /8 42 64 5/16 12 142 2 20 3 /4 SCH10 10,000 12 GA. 1 18 16 18 3 1 3 /16 42 1 /4 62 1 /4 22 42 1 /4 19 18 7 /8 42 64 5/16 12 142 2 20 3 /4 SCH13 12,500 12 GA. 1 22 16 16 3 1 3 /16 42 1 /4 58 1 /4 27 1 /4 84 27 1 /4 13 42 58 5/16 20 136 2 29 SCH15 15,000 12 GA. 2 18 16 18 3 1 3 /16 42 1 /4 58 1 /4 62 84 19 18 7 /8 42 58 5/16 16 136 2 20 3 /4 SCH20 20,000 12 GA. 2 18 16 18 4 1 7 /16 48 72 62 102 19 27 1 /8 48 70 5/16 16 154 2 20 3 /4 SCH25 25,000 12 GA. 2 22 16 16 4 1 7 /16 48 72 70 1 /2 102 27 1 /4 18 3 /4 48 70 5/16 20 154 2 29 SCH30 30,000 12 GA. 2 22 16 16 4 1 7 /16 48 72 70 1 /2 102 27 1 /4 18 3 /4 48 70 5/16 20 154 2 29 SCH35 35,000 12 GA. 2 27 1 /2 16 16 4 1 /2 1 15 /16 62 89 96 138 36 3 /4 20 3 /8 62 76 5/16 28 174 2 38 1 /2 SCH40 40,000 12 GA. 2 27 1 /2 16 16 4 1 /2 1 15 /16 62 89 96 138 36 3 /4 20 3 /8 62 76 5/16 28 174 2 38 1 /2 SCH45 45,000 12 GA. 2 27 1 /2 16 16 4 1 /2 1 15 /16 62 89 96 138 36 3 /4 20 3 /8 62 76 5/16 28 174 2 38 1 /2 Note: Specifications are subject to change. Certified prints are available. 33

Rating Tables - Series SAH (Axial Flow) Type A (less filters) UNIT SIZE EXT. 5 PSIG 0 F EAT FAN FAN MTR. (CFM*) SP** BTU/HR RISE SIZE RPM HP 8,000 0 741,200 85 32 822 1 1 /2 8,000 1/4 741,200 85 32 935 2 8,000 1/2 741,200 85 32 1055 3 8,000 1 741,200 85 32 1280 5 10,000 0 828,400 76 32 1050 2 10,000 1/4 828,400 76 32 1085 5 10,000 1/2 828,400 76 32 1170 5 10,000 1 828,400 76 32 1400 7 1 /2 12,500 0 1,199,000 88 36 833 2 12,500 1/4 1,199,000 88 36 928 2 12,500 1/2 1,199,000 88 36 979 3 12,500 1 1,199,000 88 36 1142 5 15,000 0 1,324,350 81 36 989 3 15,000 1/4 1,324,350 81 36 1046 5 15,000 1/2 1,324,350 81 36 1128 5 15,000 1 1,324,350 81 36 1240 7 1 /2 20,000 0 2,071,000 95 44 692 3 20,000 1/4 2,071,000 95 44 768 5 20,000 1/2 2,071,000 95 44 811 5 20,000 1 2,071,000 95 44 935 7 1 /2 25,000 0 2,398,000 88 48 705 3 25,000 1/4 2,398,000 88 48 746 5 25,000 1/2 2,398,000 88 48 788 7 1 /2 25,000 1 2,398,000 88 48 903 10 30,000 0 2,616,000 80 48 822 7 1 /2 30,000 1/4 2,616,000 80 48 866 10 30,000 1/2 2,616,000 80 48 912 10 30,000 1 2,616,000 80 48 992 15 35,000 0 3,433,500 90 48 916 15 35,000 1/4 3,433,500 90 48 960 15 35,000 1/2 3,433,500 90 48 992 15 35,000 1 3,433,500 90 48 1072 15 40,000 0 3,749,600 86 54 802 10 40,000 1/4 3,749,600 86 54 840 15 40,000 1/2 3,749,600 86 54 872 15 40,000 1 3,749,600 86 54 949 20 45,000 0 3,973,050 81 54 867 15 45,000 1/4 3,973,050 81 54 900 15 45,000 1/2 3,973,050 81 54 925 20 45,000 1 3,973,050 81 54 982 25 * CFM shown is net flow at discharge and includes static pressure loss for coil and shutter. ** Static pressure for calculated resistances external to the unit assembly. Type B (with filters) UNIT SIZE EXT. 5 PSIG 0 F EAT FAN FAN MTR. (CFM*) SP** BTU/HR RISE SIZE RPM HP 8,000 0 741,200 85 32 825 1 1 /2 8,000 1/4 741,200 85 32 942 2 8,000 1/2 741,200 85 32 1110 3 8,000 1 741,200 85 32 1280 5 10,000 0 828,400 76 32 1055 3 10,000 1/4 828,400 76 32 1165 5 10,000 1/2 828,400 76 32 1238 5 10,000 1 828,400 76 32 1405 7 1 /2 12,500 0 1,199,000 88 36 863 3 12,500 1/4 1,199,000 88 36 937 3 12,500 1/2 1,199,000 88 36 999 5 12,500 1 1,199,000 88 36 1142 7 1 /2 15,000 0 1,324,350 81 36 1034 3 15,000 1/4 1,324,350 81 36 1077 5 15,000 1/2 1,324,350 81 36 1143 5 15,000 1 1,324,350 81 36 1254 7 1 /2 20,000 0 2,071,000 95 44 717 3 20,000 1/4 2,071,000 95 44 770 5 20,000 1/2 2,071,000 95 44 846 5 20,000 1 2,071,000 95 44 939 7 1 /2 25,000 0 2,398,000 88 48 710 5 25,000 1/4 2,398,000 88 48 762 5 25,000 1/2 2,398,000 88 48 809 7 1 /2 25,000 1 2,398,000 88 48 928 10 30,000 0 2,616,000 80 48 860 7 1 /2 30,000 1/4 2,616,000 80 48 898 10 30,000 1/2 2,616,000 80 48 938 15 30,000 1 2,616,000 80 48 1019 15 35,000 0 3,433,500 90 48 938 15 35,000 1/4 3,433,500 90 48 976 15 35,000 1/2 3,433,500 90 48 1010 15 35,000 1 3,433,500 90 48 1079 20 40,000 0 3,749,600 86 54 816 15 40,000 1/4 3,749,600 86 54 837 15 40,000 1/2 3,749,600 86 54 886 15 40,000 1 3,749,600 86 54 953 20 45,000 0 3,973,050 81 54 872 15 45,000 1/4 3,973,050 81 54 907 15 45,000 1/2 3,973,050 81 54 936 20 45,000 1 3,973,050 81 54 997 20 * CFM shown is net flow at discharge and includes static pressure loss for coil, shutter and filter house. ** Static pressure for calculated resistances external to the unit assembly. Coil and Filter Data - Installation Weights UNIT SIZE COILS FILTERS (CFM) No. Total Face Area Number & Size Total Face Area 8,000 1 7.7 SQ. FT. (8) 25 x 20 x 2 27.76 SQ. FT. 10,000 1 7.7 SQ. FT. (8) 25 x 20 x 2 27.76 SQ. FT. 12,500 1 13.4 SQ. FT. (12) 25 x 20 x 2 41.64 SQ. FT. 15,000 1 13.4 SQ. FT. (12) 25 x 20 x 2 41.64 SQ. FT. 20,000 1 27.4 SQ. FT. (20) 25 x 20 x 2 69.40 SQ. FT. 25,000 1 27.4 SQ. FT. (20) 25 x 20 x 2 69.40 SQ. FT. 30,000 1 27.4 SQ. FT. (20) 25 x 20 x 2 69.40 SQ. FT. 35,000 2 36.8 SQ. FT. (35) 25 x 20 x 2 121.45 SQ. FT. 40,000 2 36.8 SQ. FT. (35) 25 x 20 x 2 121.45 SQ. FT. 45,000 2 36.8 SQ. FT. (35) 25 x 20 x 2 121.45 SQ. FT. UNIT FAN BASIC UNIT TYPE B TURNING WEATHER SIZE (CFM) SIZE TYPE A W/FILTERS ELBOW HOOD 8,000 32 1400 1800 320 195 10,000 32 1435 1835 320 195 12,500 36 1725 2225 360 290 15,000 36 1760 2260 360 290 20,000 44 2600 3150 560 360 25,000 48 2750 3450 560 360 30,000 48 2850 3550 560 360 35,000 48 3500 4200 690 540 40,000 54 3850 4725 690 540 45,000 54 3975 4850 690 540 34

Rating Tables - Series SCH (Centrifugal) Type A (Centrifugal - less filters) UNIT SIZE (CFM*) OUTLET VELOCITY 5 PSIG - 0 F EAT WHEEL NO. 0 EXT. SP** 1 2 EXT. SP** 1 EXT. SP** 1 1 2 EXT. SP** BTU/HR RISE DIA. WHEELS RPM HP RPM HP RPM HP RPM HP 8,000 2765 741,200 85 18 1 540 3 642 3 745 5 837 5 10,000 3445 828,400 76 18 1 642 5 750 5 832 7 1 2 925 7 1 2 12,500 2420 1,212,625 89 22 1 416 5 500 5 578 7 1 2 662 7 1 2 15,000 1835 1,340,700 82 18 2 508 5 628 7 1 2 742 7 1 2 843 10 20,000 2445 2,136,400 98 18 2 552 7 1 2 667 10 773 10 852 15 25,000 1875 2,452,500 90 22 2 418 7 1 2 500 10 582 15 658 15 30,000 2245 2,681,400 82 22 2 496 15 568 15 638 20 703 20 35,000 1430 3,357,200 88 27 1 2 2 294 7 1 2 367 10 431 15 498 20 40,000 1635 3,575,200 82 27 1 2 2 329 15 400 15 461 20 518 25 45,000 1835 3,825,900 78 27 1 2 2 356 15 423 20 481 25 532 30 **CFM shown is net flow at discharge and includes static pressure loss for coil and shutter. **Static pressure for calculated resistances external to the unit assembly. Type B (Centrifugal - with filters) UNIT SIZE OUTLET 5 PSIG - 0 F EAT WHEEL NO. 0 EXT. SP** 1 2 EXT. SP** 1 EXT. SP** 1 1 2 EXT. SP** (CFM*) VELOCITY BTU/HR RISE DIA. WHEELS RPM HP RPM HP RPM HP RPM HP 8,000 2765 741,200 85 18 1 542 3 647 3 752 5 852 5 10,000 3445 828,400 76 18 1 662 5 765 5 855 7 1 2 933 7 1 2 12,500 2420 1,212,625 89 22 1 432 5 507 5 592 7 1 2 673 7 1 2 15,000 1835 1,340,700 82 18 2 542 5 653 7 1 2 755 7 1 2 853 10 20,000 2445 2,136,400 98 18 2 571 7 1 2 678 10 788 10 872 15 25,000 1875 2,452,500 90 22 2 444 10 512 10 596 15 677 15 30,000 2245 2,681,400 82 22 2 508 15 586 15 652 20 721 20 35,000 1430 3,357,200 88 27 1 2 2 300 7 1 2 378 10 442 15 505 15 40,000 1635 3,575,200 82 27 1 2 2 339 15 408 20 471 20 526 25 45,000 1835 3,825,900 78 27 1 2 2 371 15 433 20 493 25 544 30 **CFM shown is net flow at discharge and includes static pressure loss for coil and shutter. **Static pressure for calculated resistances external to the unit assembly. Coil and Filter Data - Installation Weights UNIT SIZE COILS FILTERS (CFM) No. Total Face Area Number & Size Total Face Area 8,000 1 7.7 SQ. FT. (8) 25 x 20 x 2 27.76 SQ. FT. 10,000 1 7.7 SQ. FT. (8) 25 x 20 x 2 27.76 SQ. FT. 12,500 1 13.4 SQ. FT. (12) 25 x 20 x 2 41.64 SQ. FT. 15,000 1 13.4 SQ. FT. (12) 25 x 20 x 2 41.64 SQ. FT. 20,000 1 27.4 SQ. FT. (20) 25 x 20 x 2 69.40 SQ. FT. 25,000 1 27.4 SQ. FT. (20) 25 x 20 x 2 69.40 SQ. FT. 30,000 1 27.4 SQ. FT. (20) 25 x 20 x 2 69.40 SQ. FT. 35,000 2 36.8 SQ. FT. (35) 25 x 20 x 2 121.45 SQ. FT. 40,000 2 36.8 SQ. FT. (35) 25 x 20 x 2 121.45 SQ. FT. 45,000 2 36.8 SQ. FT. (35) 25 x 20 x 2 121.45 SQ. FT. UNIT FAN TYPE A TYPE B WEATHER SIZE (CFM) SIZE BASIC UNIT W/FILTERS HOOD 8,000 18 1680 2080 195 10,000 18 1705 2105 195 12,500 22 1999 2499 290 15,000 18 2007 2507 290 20,000 18 2680 3180 290 25,000 22 3159 3784 360 30,000 22 3249 3874 360 35,000 27 1 /2 3320 4420 540 40,000 27 1 /2 3410 4410 540 45,000 27 1 /2 3428 4428 540 35

Series 77 Steam Unit Heaters Series 77 Steam Unit (1-Row) Series 77 Steam Unit (2-Row) Hartzell direct drive steam unit heaters are powered to utilize the full high heat transfer efficiency of the unit by efficient translation of power into air movement. The characteristics which make a unit heater so superior to heating devices which depend on radiation are the ability to quickly extract a very high proportion of the heat contained within the primary heating element and to distribute that heat evenly. The key to economy and quality of performance lies in the propeller which forces air through the heater and distributes it evenly and thoroughly into all corners and recesses of the area to be heated. The Hartzell steam unit heater is equipped with either 1-row coils (Series 771) or 2-row coils (Series 772) of the fin and tube type, high efficiency cast aluminum propeller direct connected to a totally enclosed fan duty motor. Two 1/2 13 N.C. tapped holes for support rods provided. See page 3 for performance data. Special coil sections may be provided to meet specific application requirements. The Cores in unit heaters have copper headers and seamless copper tubes with copper brazed joints, and copper fins. Varied fin spacing. Cores are guaranteed up to 150 psig saturated steam and 366 F. Standard mounting of the steam unit heater is in vertical position, capable of being tilted as much as 60 downward. Rugged steel support rods and motor base are standard on Hartzell steam unit heaters. The Ideal Heating Unit Initial Cost Lower per square foot of area to be heated than any other method of heating. Installation Cost May be installed in about a fourth of the time required for radiation. Heat Circulation Distributes heat thoroughly. Eliminates cold spots and cold floors. Space Saving Suspended along a wall, beam or ceiling, the average Hartzell unit heater saves at least 45 square feet of usable floor space. Instant Action Touch a switch when heat is needed (or do nothing at all if thermostatic control is used) and heat is produced instantly... no waiting. Louvers Adjustable louvers can be individually set to deliver heat at the exact point desired. Appearance Fabricated steel cabinet with air dry enamel coating. Tips on Placement of Unit Heaters Place units at the points of greatest heat loss (doorways, windows, etc.) Place heaters so that the air stream wipes the outside walls, and the throw from one heater reaches to the next unit. This sets up a circulatory air movement that produces a blanket of warm air along the cold wall. Arrange units so they do not blow directly on workers. Aim air streams down aisles, toward open spaces on the floor, or along exterior walls. Locate heaters so that air streams are not blocked by columns, machinery, partitions, etc. Position units in a building or exposed to a prevailing wind to direct a large portion of the heated air along the windward side. Accessories: Safety Guard Protective rear safety guard of 14 gauge steel is available as an option. 36

Dimensions and Performance Principle Dimensions Weight* Size A B C D E F G H J K L (lbs) 12 20 7 /16 12 16 3 /4 10 3 /8 7 3 /8 2 1 /2 1 1 /2 4 7 /8 8 3 /8 22 12 1 /8 46 18 26 7 /16 18 22 3 /4 16 3 /8 9 1 /4 2 1 /2 1 1 /2 6 3 /4 11 3 /8 24 1 /4 18 1 /8 75 20 29 7 /16 21 25 3 /4 19 3 /8 9 1 /4 2 1 /2 1 1 /2 6 3 /4 12 7 /8 24 3 /4 21 1 /8 90 24 32 7 /16 24 28 3 /4 22 3 /8 9 1 /4 2 1 /2 1 1 /2 6 3 /4 14 3 /8 25 3 /4 24 1 /8 111 28 41 7 /16 33 37 3 /4 31 3 /8 10 3 1 /4 2 6 3 /4 18 7 /8 27 1 /2 33 1 /8 168 * Weight is less motor. Rating Table Series 771 and Series 772 Steam Unit Heater Performance Data 5 Pound Steam Pressure and 60 Entering Air Code No. 1-Row Coils 2-Row Coils No. Face Series 771 Face Series 772 Size Type BTU E.D.R. BTU E.D.R. (per hr.) F per hr. (sq. ft.) (per hr.) F per hr. (sq. ft.) of Blades HP RPM CFM Velocity (FPM) Final Temp. Lbs. cond. CFM Velocity (FPM) Final Temp. Lbs. cond. 12 OD3 4 1/4 1725 540 550 31,000 112 32.3 129 470 479 40,300 137 41.9 168 18 WE3 4 1/3 1725 2060 933 124,000 114 129 518 1800 815 145,000 132 150 603 20 ND3 2 1/4 1725 2250 749 151,000 120 157 630 1880 626 168,000 141 175 701 20 LF3 3 1/2 1725 3190 1060 180,000 111 187 751 2660 885 206,000 130 215 860 20 WG3 4 3/4 1725 3400 1130 186,000 109 193 773 2790 929 212,000 128 220 883 24 ND3 2 1/4 1725 2850 726 205,000 125 213 855 2480 632 221,000 140 230 922 24 NF3 2 1/2 1725 3660 933 233,000 117 243 973 3160 805 255,000 133 265 1060 24 PH3 6 1 1750 5400 1380 281,000 107 293 1170 4690 1200 318,000 121 331 1330 24 WF4 4 1/2 1140 3260 831 220,000 121 229 917 2900 739 243,000 135 252 1010 28 NF3 2 1/2 1725 5420 730 368,000 121 382 1530 4850 654 427,000 139 444 1780 28 NG3 2 3/4 1725 6760 911 413,000 115 429 1720 6010 810 484,000 133 503 2020 28 WH4 4 1 1150 8000 1080 448,000 111 466 1870 6900 930 524,000 128 545 2180 37

Options and Accessories (Please note applicable series by each option/accessory item) Filter Box The addition of the filter box section to the gas air makeup unit enables tempered and filtered air to be brought into the building. Available for all models. Disposable or washable filters are available. Available for all units. Horizontal Inlet Weatherhood Effectively prevents the entry of weather during operation, and is designed to mount directly to the inlet of the unit that is installed horizontally outdoors; or when the unit is mounted horizontally indoors the weatherhood can be attached to the outside wall of the building. See page 10, installation type HI1 & HI2, HO1 & HO2 and V1. Available for all units. Vertical (Roof) Inlet Weatherhood These hoods are used when the unit is installed below the roof, and the weather hood is curb mounted above the roof. The foursided roof ventilator hood is a low velocity design to prevent entrainment of water, and is constructed of galvanized steel. This style hood can be used on models GFR 2,000 through 75,000 CFM. Connecting duct to the unit, by others. See page 10, installation types HI3 and HI4. Available Series SMP Vertical Unit only. Motor Operated Shutter Prevents the entry of outside air when unit is not in operation. Standard on steam units. Available for GFR, GMC, and GMP. Gas Regulators Various sizes and pressure capabilities available. Available for GFR, GMC, GMP, 78V or H, and 79. Vibration Isolators Spring type or rubber-in-shear available for entire unit or blower only. Available for GFR, GMC, GMP, and SFC. Perimeter Curb Mount Accommodates weather and leakage protection when the unit is mounted on a full perimeter pre-fabricated roof curb. Available for GFR, GMC, GMP, and SFC. Pre-fabricated Roof Curb Full perimeter mount with built-in wooden nailer strip that facilitates fastening the unit to the curb. Includes a rigid 1-1/2 thick, 3-pound density glass fiber liner, which eliminates condensation problems. 1/2 Neoprene sealer strip is standard. Construction is galvanized steel with fully welded seams. Available for GFR, GMC, GMP, and SFC Turning Elbow Turns the inlet or discharge airflow 90 degrees with the aid of guide vanes. Minimal friction loss. Available on GMC, GMP, and SMP. 2- and 4-way Diffusers Direct the discharge airflow. Available for GFR, GMC, GMP, and SFC. Service Platform Provides a safe and convenient station to service the unit. Available for GFR, GMC, GMP, and SFC 38

Options and Accessories (Please note applicable series by each option/accessory item) Combination Motor Cover and Belt Guard Provides weather protection as well as guarding of the drive sheave and belts. Available on SMP, SMC, SAH, AND SCH. Evaporative Cooling System Contact factory. Available on GMP and GMC. Door Guards Provide guarding of the internal drive assembly, by limiting access to the interior of the unit. Available for GFR, GMC, and GMP. Insulated Housings Single wall pinned insulation or double wall insulated construction. Available for GFR, GMC, GMP, and SFC. Cupro-Nickel Coil Can be substituted for standard coils at higher steam pressures. Offers increased coil life. Available on SFC, 77, SMP, SMC, SAH, and SCH. Room Temperature Control Provides floor control of unit s output temperature. Available for GFR, GMC, GMP, SFC, SMP, SMC, SAH, and SCH. Caution: The drive assembly on the periphery of the blades of a fan less than seven (7) feet above the floor or working level must be guarded to be in accordance with OSHA regulations. SHIPPING INFORMATION: Accessories are shipped separately with hardware available for field mounting and must be assembled to basic unit on job site. SAFETY ACCESSORIES, APPLICATION AND USE WARNING The safe application and use of equipment supplied by Hartzell Fan, Inc. is the responsibility of the installer, the user, the owner, and the employer. Since the application and use of its equipment can vary greatly, Hartzell Fan, Inc. offers various product types, optional safety accessories, and sound performance data per laboratory tests. Hartzell Fan, Inc. sells its equipment with and without safety accessories, and accordingly, it can supply such safety accessories only upon receipt of an order. The need for safety accessories will frequently depend upon the type of system, fan location and operating procedures being employed. The proper protective safety accessories to meet company standards, local codes, and the requirements of the Occupation Safety and Health Act must be determined by the user since safety requirements vary depending on the location and use of the equipment. If applicable local conditions, standards, codes or OSHA rules require the addition of the safety accessories, the user should specify and obtain the required safety accessories from Hartzell Fan, Inc. and should not allow the operation of the equipment without them. Owners, employers, users and installers should read RECOMMENDED SAFETY PRACTICES FOR USERS AND INSTALLERS OF INDUSTRIAL AND COMMERCIAL FANS published by the Air Movement and Control Association International, Inc., 30 West University Drive, Arlington Heights, Illinois 60004. A copy of this publication is enclosed with each fan shipped from Hartzell Fan, Inc., and is available upon request at Hartzell s office in Piqua, Ohio 45356. Please contact Hartzell Fan, Inc. or your local Hartzell representative for more information on product types, safety accessories, and sound performance estimates. Remember, the selection of safety accessories and the safe application and use of equipment supplied by Hartzell Fan, Inc. is your responsibility. 39

Hartzell Warranty LIMITED WARRANTIES Hartzell represents to Buyer that any goods to be delivered hereunder will be produced in compliance with the requirements of the Fair Labor Standards Act of 1938 as amended. Hartzell also warrants to Buyer its goods to be free from defects in workmanship and material under normal use and service for one (1) year after tender of delivery by Hartzell, plus six months allowance for shipment to approved stocking dealers and distributors. No warranty extends to future performance of goods and any claims for breach of warranty or otherwise accrues upon tender of delivery. The foregoing constitute Hartzell s sole and exclusive warranties and are in lieu of all other warranties, whether written, oral, express, implied or statutory. LIMITATION OF LIABILITY FOR BREACH OF WARRANTY Hartzell s obligation for any breach of warranty is limited to repairing or replacing, at its option, without cost to Buyer at its factory any goods which shall, within such a warranty period, be returned to it with transportation charges prepaid, and which its examination shall disclose to its satisfaction to have been defective. Any request for repair or replacement should be directed to Hartzell Fan, Inc., P.O. Box 919, Piqua, Ohio 45356. Hartzell will not pay for any repairs made outside its factory without its prior written consent. This does not apply to any such Hartzell goods which have failed as a result of faulty installation or abuse, or incorrect electrical connections or alterations, made by others, or use under abnormal operating conditions or misapplication of the goods. LIMITATION OF LIABILITY To the extent the above limitation of liability for breach of warranty is not applicable, the liability of Hartzell on any claim of any kind, including negligence, for any loss or damage arising out of or connected with, or resulting from the sale and purchase of the goods or services covered by these Terms and Conditions of Sale or from the performance or breach of any contract pertaining to such sale or purchase or from the design manufacture, sale, delivery, resale, installation, technical direction installation, inspection repair, operation or use of any goods or services covered by these Terms and Conditions shall, in no case exceed the price allocable to the goods or services which gave rise to the claim and shall terminate one year after tender of delivery of said goods or services, plus six months allowance for shipment to approved stocking dealers and distributors. In no event will Hartzell be responsible or liable for any labor or other incidental costs associated with the removal or replacement of defective products or materials. In no event whether as a result of breach of contract, or warranty or alleged negligence, defects, incorrect advice or other causes, shall Hartzell be liable for special or consequential damages, including, but not limited to, loss of profits or revenue, loss of use of the equipment or any associated equipment, cost of substitute equipment, facilities or services, down time costs, or claims of customers of the Buyer for such damages. Hartzell neither assumes nor authorizes any person to assume for it any other liability in connection with the sale of its goods or services. NO IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS DOES NOT WARRANT THAT SAID GOODS ARE OF MERCHANTABLE QUALITY OR THAT THEY ARE FIT FOR ANY PARTICULAR PURPOSE. THERE IS NO IMPLIED WARRANTY OF MERCHANTABILITY AND THERE IS NO IMPLIED WARRANTY OF FITNESS. Propeller Fans Cooling Tower & Heat Exchanger Fans Duct Fans Duct Axial Fans Vaneaxial Blowers Cool Blast & Utility Fans Steel Centrifugal Blowers Roof Ventilators Steel & Fiberglass Heating Equipment Gas & Steam Fiberglass Axial Flow Fans Fiberglass Centrifugal Blowers Hartzell Fan, Inc., Piqua, Ohio 45356 Plants in Piqua, Ohio and Portland, Indiana. Marine Mine Duty Blowers Litho in U.S.A. A-125-E 1/11