ALARM TRANSFER SYSTEM

Similar documents
NAUTOCONNING (Ethernet) BOX -PC

Indicator Equipment OPERATOR MANUAL. Rate Gyro, Type Operator Unit, Type consisting of:

GMDSS Signal Unit POWER MONITOR

7NG , 7NG

Assembly Instruction GfS Door Terminal

ClassNK Technical Information No. TEC-0838 (iii) The dormant period, visual indication, first stage audible alarm, second stage remote audible alarm a

725B Configuration Software Manual

SIMPLICITY BY DESIGN M52 CONTROLLER

WHA 3000P Hot Air Station

Entero Voice Alarm system.

Instruction manual MTL process alarm equipment. October 2016 CSM 725B rev 2 MTL RTK 725B. Configuration Software Manual

Added password for IP setup page : Password must be in IP format!

PBI Manual. Paradox to KNX-BUS Interface

CBI-064. User Manual. Caddx to KNX-BUS Interface

1.5. System description of Bridge Navigation Watch Alarm System (BNWAS 3000)

MODBUS MESSAGING to the S5 BATTERY VALIDATION SYSTEM

Centaur TM II Cube Slave Alarm Signalling Equipment INSTALLATION GUIDE

RULES PUBLICATION NO. 35//P ONE MAN BRIDGE OPERATED (OMBO) SHIPS March

To operate the 5207 you can use either the built-in touchpad or the Model 5230 Remote Annunciator.

User manual. ABB i-bus EIB. Zone Terminal MT/S Intelligent Installation System ABB STOTZ-KONTAKT

Remote alarm indicator and test combination MK2430

Instruction manual. W440 AIS Sart Sniffer

Application Manual Loop Water Controller

Product Data Sheet. Remote Terminals. Features:

HERCULES 6 GRAPHICS SYSTEM

Configuring Alarm Rule for Video Analytics Detector

ZLM4 OEM Technical Manual

DOCUMENTATION IPS640

DOCUMENTATION IPS640

WHA 3000V Hot Air Station

Dipl.-Ing. W. Bender GmbH & Co. KG Londorfer Str Grünberg Phone: Fax:

Entwicklung + Fertigung + Service: Heerweg 15 D, Denkendorf Tel.: / Fax.: /

AM1 alarm module. RESOL AM1 alarm module * * Mounting Connection Function. Manual

HANDBUCH / MANUAL / MANUEL / MANUALE TopScan-S

Clino Guard. Intelligent Life Care. Solutions for safe and efficient care

Operating & Maintenance Manual. Alert-4 Ethernet LCD Master Alarm

NIPPY junior+ Quick Reference Guide

Entero Voice Alarm system. User guide

Dryer Controller M720

1.6. Installation instructions for Bridge Navigation Watch Alarm System (BNWAS 3000)

Technical Manual. Level Alarm Unit CARLA & WIDS

FIRERAY 5000 range USER GUIDE

PowerWizard. Level 1.0 & Level 2.0 Control Systems Training

QS941A Controller User Interface

Installation instructions. For the competent person. Installation instructions VRT 350 VRT 350 GB, IE

Products no longer available

ModSync Sequencing System Installation & Operation Manual. For use with Fulton Steam Boilers.

Jetstream Series HPLC - PELTIER COLUMN-THERMOSTATS 1. GENERALITIES

Sirius Control Box 6130 LRIT

BR

Ethernet General Purpose

Manual# User s Manual. 200 Series. DCU 210/208 Diesel Engine Control Unit RP 210 Remote Panel

KNX module for smoke alarm devices Dual/VdS and Q-Label (Order no )

Laptop / PC Programming Manual

Operation & Maintenance Manual

Revision November 2013 JVA Technologies. Ethernet General Purpose IO Technical Manual

SUPREMATouch. Modular Fire & Gas Detection System

CONTENTS USING THE LIGHTS KEY...31 NETWORK ALARMS...32 FAULT AND ERROR MESSAGES...33

CONTROL PANEL INTERFACE ACTIVATE THE GENERATOR DISPLAY INTERFACE MENUS. Control Panel USING THE AUTO/OFF/MANUAL SWITCH

D1255RB/D1256RB/D1257RB

Intelligent Security & Fire Ltd

Operating Manual VMD420

1 measurement signal input 4-20 ma for connection to an external gas sensor 5 freely programmable alarm switching points per measuring point

CONTENTS INSTALLATION 21 USING THE SIGNAL KEY 10 SPECIFICATION 23

DYGIZONE GJD910 Lighting Controller & Enunciator

Table of Contents. Part I SAFETY MESSAGE TO INSTALLERS OF EMERGENCY WARNING EQUIPMENT 2 Part II Vehicle Operation 4. Part III Safety Messages 13

IRIS Touch Firmware Enhancements and Additions from Version to Version

Networked Access Control Panel. Installation Guide

operating device LOD , 144x72mm designed for retrofit

The Kryos LN2 Liquid Level Control & Cryogenic Temperature Control

Any additional devices linked to the system ET08 (computer, sensors, relays etc.) must be approved by LST EN standard.

MAKING MODERN LIVING POSSIBLE. CP715Si. Electronic 2-Channel Common Timebase Programmer for Heating and Hot Water. User Guide.

SIRe Competent Air Curtains Water With quick guide. SIReAC. For wiring diagram, please see p Original instructions

REPEATER FS5200R OPERATION MANUAL

User Manual. Dryer Controller M720

DC VOLTMETER DCV-10 / 10A / 10C / 10S / 10CS / 11 / 11A / 11C / 11S / 11CS. A4741 / Rev.1

TS2500. Intruder Alarm Control Panel. SYSTEM OPEN 17:30 01 Jan ENT ESC. Setting the System. Unsetting the System RE SET

WELCOME. The human touch in technology. marine

Refrigeration and Air Conditioning Controls. User s manual. Degree Master Controller in AKC 55 Systems ADAP-KOOL REFRIGERATION AND AIR CONDITIONING

OPERATING INSTRUCTIONS

SUPERINTEND VRE-08/16/32/64

ALARM SYSTEM USER S MANUAL Rev

User Manual Doc.Ref : JA-KNX-UM. JA-KNX Jablotron KNX Interface ELAUSYS JA-KNX. KNX Interface for Jablotron alarm system.

Radio fire warning panel SRC 3000

USER MANUAL FOR OPERATING SYSTEM

ibox Modbus Server Gateway for the integration of Notifier ID3000 / ID3002 / ID60 / ID50 fire panels in Modbus enabled monitoring and control systems

SuperCELL Model SC500-H-SM User s Information

Original operating instructions Safety switch with guard locking AC901S AC902S

APC BC300 Series 40kW 208/450/480V User Guide

ZM20 OEM Technical Manual

GPS Evaluation Kit EVA1037/1080

Silencer Preheater unit Electric post-heating unit Water circulated post-heating unit CO 2 sensor %RH sensor Pressure difference switch LON converter

Exercise 8. Controlling a Batch Mixing Process EXERCISE OBJECTIVE

21-light Remote Annunciator. Owner s Manual

Y-Plant Alert. Alarm Annunciator and Sequence of Event Recording System. BU 04M01A02-01E-A

BSR Addressable Fire Detection control panel. Installation operation manual

Operating instructions. For the operator. Operating instructions VRT 350. Room temperature-controlled controller GB, IE

SUPREMATouch. Modular Fire & Gas Detection System

Quick Installation Manual LED Touch Keypad Autodial Wireless Alarm System

Monitor Alarms and Events

Transcription:

aytheon Anschütz GmbH Postfach 1166 D - 24100 Kiel Tel+49-431-3019-0 Fax+49-431-3019-501 Email Service@raykiel.com www.raytheon -anschuetz.de ALAM TANSFE SYSTEM (Box -Pc) Description 4095.DOC000002

Weitergabe sowie Vervielfältigung dieser Unterlage, Verwertung und Mitteilung ihres Inhaltes nicht gestattet, soweit nicht ausdrücklich zugestanden. Zuwiderhandlungen verpflichten zu Schadenersatz. Toute communication ou reproduction de ce document, toute exploitation ou communication de son contenu sont interdites, sauf autorisation expresse. Tout manquement à cette règle est illicite et expose son auteur au versement de dommages et intérêts. Copying of this document, and giving it to others and the use or communication of the contents thereof, are forbidden without express authority. Offenders are liable to the payment of damages. Sin nuestra expresa autorización, queda terminantemente prohibida la reproducción total o parcial de este documento, así como su uso indebido y/o su exhibición o comunicación a terceros. De los infractores se exigirá el correspondiente resarcimiento de daños y perjuicios.

aytheon Anschütz GmbH SAFETY NOTES: S Warning! Take care during maintenance and repair work: avoid touching live electrical connections. The applicable safety regulations such as VDE, VBG 4, OSHA 1919 and other appropriate safety standards must be followed. S The installation and first putting into operation may only be performed by trained and qualified personnel. S Maintenance and repair work may only be performed by trained and qualified personnel having knowledge of the national safety regulations for this type of equipment. S The equipment can be damaged! Parts may only be replaced when the supply voltage is switched off. A

B

aytheon Anschütz GmbH Table of Contents 1 General... 1-1 1.1 Construction... 1--1 1.2 Alarm Sources... 1--2 1.2.1 Emergency Call--Function... 1--3 1.2.2 Mute Function... 1--3 1.3 Description... 1--4 1.3.1 Alarm Manager... 1--4 1.3.2 Functional description... 1--6 1.3.3 Conning Alarm Panel... 1--8 1.3.3.1 Configured as Central Alarm Panel... 1--9 1.3.3.2 Configured as Watch Time Monitor... 1--10 1.3.3.3 Signal Unit - NAUTOALAM (Option)... 1--11 1.3.4 Conning Display... 1--12 1.3.4.1 Conning Display - ALAM --... 1--12 1.3.4.2 Conning Display - ON DUTY -... 1--13 1.3.5 Status Converter... 1--14 1.3.6 Watch Alarm Activator... 1--14 1.3.7 Watch Alarm (Timer) eset... 1--15 1.3.8 esetting the Watch Alarm Timer... 1--15 1.3.9 Setting the Watch Alarm Timer... 1--16 1.3.9.1 Conning Display... 1--17 2 Servicing, maintenance and repair... 1-18 2.1 Safety instructions... 1--18 2.2 Servicing and maintenance... 1--18 2.3 epair... 1--19 2.3.1 Explanation of the symbols... 1--19 2.3.2 Control Unit... 1--20 2.3.2.1 Exchanging the control unit pcbs... 1--23 Annex I

aytheon Anschütz GmbH 1 General A default Nautoconning System consists of: Navigation Data Manager (see separate Manual no. 3884) Conning Display see separate Manual no. 4094) As an option a Alarm Transfer System can be added (see annex, Block Diagram) : Navigation Data Manager Conning Display Alarm Transfer System (ATS) The Alarm Transfer System is a management system for incoming alarm messages, system state signals and the Watch Alarm. Independent from the default NAUTOCONNING System, the Alarm Transfer System is equipped with an own power supply. So the Alarm Transfer System including Watch Alarm Control is operative even if the Conning Display or the Navigation Data Manager broke down. 1.1 Construction The Alarm Transfer System consists of the following units: Alarm Manager Nautoconning Display Data Manager Conning Alarm Panel Ethernet Switch Status Converter or SIgnal Unit Watch Alarm Activator Watch Alarm (Timer) eset 1--1

1.2 Alarm Sources Alarms can caused by the following devices: ECDIS ADA Nav. Sensor Inputs Autopilot NP20xx Gyro Compass STDxx Watch Alarm Activator Other essential system specific navigation equipment (NMEA format) Magnetic Compass TMC The following warnings and errors are basically included in the Alarm Transfer System: - Collision warnings (ADA) - X-track (ECDIS) - Off-course (NP20xx) - Compass course (STDxx) Detailed information about the full range of indicated warnings and errors can be referred to the corresponding device manuals. 1--2

aytheon Anschütz GmbH 1.2.1 Emergency Call -Function This function allows (e.g. the guard officer) to send an Emergency Call from the bridge to the captains room by pressing the WATCH ALAM ESET BUTTON. Situation: One Man Bridge, the guard officer required urgently manoeuvre assistance. Action: Press the WATCH ALAM ESET BUTTON for 5s. The Watch Alarm is immediately activated. 1.2.2 Mute Function The Mute Function is used to acknowledge the acoustical alarm. An acknowledgement of some active alarms are possible. An acknowledgement of an important alarm is not possible. In this situation you have to check the situation directly at the e.g. ECDIS or adar. Situation: The Alarm Transfer System detects a alarm signal from e.g. the ECDIS. The Conning Alarm Panels and (if possible) the Signal Units sounds. Action: Press the Alarm key on a Conning Alarm Panel or on a Signal Unit. The acoustical alarm switches off. Check the Alarm Message in the ECDIS messages display area. For acknowledging the Alarm Message press the softbutton Acknowledge per mouse key. 1--3

1.3 Description (see annex, Block Diagram) 1.3.1 Alarm Manager The alarm manager (ALM) has the following tasks: -- To read the status of external devices and to place them on the Ethernet for display on the CONNING Display. -- To read alarms form external devices (e.g. compass, autopilot) from the Ethernet and DV bus, to generate appropriate alarm messages and send them to the desired Display. The alarm manager consists of two pcb s for power supply and two pcb s for the alarm process managing. The pcb s are located in a 19 rack (see Figure: 1--1). The back--plane is used as pcb holder and central distribution for the internal power supply and data transfer per CAN--BUS technology. Power supply The Power Supply Unit can be connected to 230 VAC ship power or directly to 24 VDC ship power. The second DC Power Supply generates the supply voltage (+ 5 and +15 DCV) for the Alarm Manager and the Alarm Slave. Alarm process managing The Alarm Manager is a Vx --Works PC that handles the Alarm List and communicates to the CAN--BUS. The Alarm Manager is connected to the Ship Ethernet Network. The Alarm Slave Microprocessor handles the DV--BUS and all specific Alarm Units (e.g. Status Converter or Signal Unit). Independent from the NAUTOCONNING system, the Alarm Manager is supported with an separate power supply. In case of NAUTOCONNING break down, the Alarm Manager is full operative! 1--4

aytheon Anschütz GmbH The Alarm Manager consists of the following pcb s (see Figure: 1--1) : 1 Power Supply (+ 5 and + 15 VDC) 2 Alarm Manager 3 Alarm Slave 4 Power Supply Unit (24 VDC) 1 2 3 4 Figure: 1--1 Alarm Manager 1--5

1.3.2 Functional description ALAM MANAGE Alarm Data Interface NavData Interface ETHENET Watch Monitoring Alarm Management NavData Monitoring DV Bus Device Monitoring (Gyro/Autopilot) Alarm Status Output Management Alarm Status Input Management internal CAN BUS (back--plane) ALAM SLAVE Status Converter Interface Alarm Indication (Alarm Panel) DV BUS INTEFACE DV BUS Figure: 1--2: Block Diagram ALAM MANAGE After the equipment has been switched on, or after a ESET, the MASTE interrogates all the connected SLAVES and collects information regarding the transmitting and receiving interfaces, saving the coupling between source and target in an internal table. Messages corresponding to all the possible alarms in the system are stored in another table. Now if in operation the MASTE determines through cyclical interrogations of the Ethernet and DV bus that, for example, the position has failed, the appropriate alarm message is retrieved from the MASTE s internal table and sent to the 1--6

aytheon Anschütz GmbH output interface provided (e.g. for CONNING ALAM PANELS). The same procedure occurs if an alarm is recognized that has already been placed on the Ethernet or the DV bus by an external device (Compass, Autopilot, Ecdis, adar). Alarm inputs are transferred to the Alarm Manager via the status converter. In addition to that (as an option) status inputs can also be shown on the Signal Unit (NAUTOALAM). 1--7

1.3.3 Conning Alarm Panel The Conning Alarm Panel can be used as Central Alarm Panel or normal Conning Alarm Panel. In this case the Central Alarm Panel can be configurated as Alarm Panel or as Combi--Alarm Panel. The Alarm Panel displays the actual Alarm and sets the acoustical Alarm. The Alarm Panel used as Combi--Alarm Panel displays the actual Alarm, set the acoustical Alarm and displays the Pre--Warning Watch Alarm in combination with the Watch Alarm devices. The normal Conning Alarm Panel can be configurated as Alarm Panel, as Combi--Alarm Panel or as Watch Time Monitor. The Watch Time Monitor displays the Watch Alarm Timer. This diversity device configurations are ship--specific and have to be done by the service agent. All Conning Alarm Panel can be manually set to alarm mode ON DUTY or STANDBY from the CONNING Display or from the Central Control Alarm Panel (Bridge). Alarm Modes: ON DUTY: Alarm monitoring enabled. The Alarm text strings can be listed on the display by the LIST button. Active alarms are displayed (depending on Conning Alarm Panel configuration) and can be acknowledged. STANDBY: No alarm monitoring. MONITO: Allows alarm listing and acknowledgement if the Control Alarm Panel is configurated In STANDBY mode. 1--8

aytheon Anschütz GmbH 1.3.3.1 Configured as Central Alarm Panel The Central Control Panel is always in ON DUTY mode. It is possible to configure each connected Conning Alarm Panel to ON DUTY or STANDBY by Monitor button (equal to Display ON DUTY on Conning Display). address...00...indicates the Central Alarm Panel status. ON DUTY 00 ON Figure: 1--3 Central Alarm Panel: ON DUTY configuration If the Watch Alarm Activator is switched off, the watch time can be set. SET: 08:48 min Figure: 1--4: Central Alarm Panel: SET TIME Indications Comment/Notes Setting the Watch Alarm Timer < > SET: 08:48 min used as ENTE key 1--9

1.3.3.2 Configured as Watch Time Monitor If the Conning Alarm Panel is configured as a Watch Time Monitor, the alarm monitoring is not active. Only the actual watch time is displayed. TIME: 08:48 min Figure: 1--5 Conning Alarm Panel used as Watch Time Monitor 1--10

aytheon Anschütz GmbH 1.3.3.3 Signal Unit - NAUTOALAM (Option) Subsystems and devices are monitored with the NAUTOALAM signal unit. The unit can display up to 15 operating conditions (gyro, pumps etc.) or errors. Operating conditions are signalized by means of a dimmable continuous light, and errors by flashing light and an acoustic signal. Since the signalized operating conditions can be caused by grouped alarms, more detailed information is only available via the alarm listings on the Conning Display or the Conning Alarm Panel. An acknowledgement of an active alarm is not possible. UDDE SYNCH ON GYO TEMP. GYO 1 UNNIN G Figure: 1--6: NAUTOALAM Signal Unit 1--11

1.3.4 Conning Display 1.3.4.1 Conning Display - ALAM - The Display ALAM has to be selected. The Conning Display is designed as a redundancy alarm display to the Master Conning Alarm Panel. On all data displays an ALAMS section is visible (see Figure: 1--7), which includes the same functionality as the Conning Alarm Panel. The ALAM LIST indicates all active and acknowledged Alarms in a list. A still active alarm (not yet acknowledged) is indicated in red. A still standing in line alarm (but already acknowledged) is indicated in white and remains so long in the alarm list until the trouble source is fixed. Figure: 1--7: Alarm Display In the lower left part of the ALAM Display, which is signed ALAMS the last active Alarm is shown as a text string and can be acknowledged. The actual Watch Time is indicated in the textbox WATCH TIME and can be modified as shown in chap. 1.3.9. 1--12

aytheon Anschütz GmbH 1.3.4.2 Conning Display - ON DUTY - The Display ON DUTY has to be selected. Via the Menu function it is possible to set specified Conning Alarm Panel to ON DUTY or to STANDBY. Alarm Units which are labeled with ON DUTY FIX can not be changed to STANDBY. The actual status is listed in the list field CONFIG ALAM ON DUTY. Figure: 1--8: Display ON DUTY 1--13

1.3.5 Status Converter The status converter converts external status signals (collision alarm, door contacts etc.) into a serial signal (S422) and transfers it to the alarm manager slave pcb. The signal management and assignment of the output signals is carried out by the alarm manager (see status converter description). 1.3.6 Watch Alarm Activator If the key is switched to OFF no W1 Alarms are transferred within the system. If the key is switched to ON the Watch Alarm is in permanent operation. If the key is switched to AUTO and the AUTOPILOT is switched to TACK or HEADING Control, the Watch Alarm is working automatically. Acc. MSC 128 the Watch Alarm will be automatically brought into operation whenever the ship s heading or track control system is activated and inhibited when this system is not activated (Watch Alarm Activator in position AUTO ). Figure: 1--9 Watch Alarm Activator 1--14

aytheon Anschütz GmbH 1.3.7 Watch Alarm (Timer) eset By pressing the reset button the Watch Alarm timer will be reseted. (see also chap. 1.2.1). Figure: 1--10 Watch Alarm (Timer) eset 1.3.8 esetting the Watch Alarm Timer A Watch Alarm Timer reset to the preset interval is carried out by acknowledgement of the alarm at the corresponding device (Conning Alarm Panel, Central Alarm Panel and Watch Time Monitor see chap. 1.3.3), Watch Alarm eset button (see chap. 1.3.7) or adar or ECDIS. A prolonged pressing of one of these buttons doesn t block the Alarm Transfer System, the watch time interval is released. 1--15

1.3.9 Setting the Watch Alarm Timer The Watch Alarm Timer is basically set on the CONNING Display. Only if NAUTOCONNING broke down, the watch alarm timer can be set at a Conning Alarm Panel, which has been configured as a Central Panel. The Watch Alarm Timer can only be set if the key switch of the Watch Alarm Activator has been activated. 3--12min* Alarm Sequence without Acknowledgements Start / Last Watchtime eset Third stage remote alarm Second stage remote audible alarm First stage bridge audible alarm Visual Indication Td Td + 15s Td + 30s Td + 2.0* minutes Td = Selected Dormant Period * = System specific configuration 1 2 3 4 1 Pre--Warning 2 Watch Alarm 1 3 Watch Alarm 2 4 Watch Alarm 3 1--16

aytheon Anschütz GmbH 1.3.9.1 Conning Display Indications Comments/Notes [1] Watch Alarm Watch Alarm Activator key symbol Key symbol is visible; the watch alarm activator is switched to OFF. The preset watch time settings can be selected. [2] Watch Alarm settings For detailed operation see CONNING DISPLAY System Description (Docu. No. 3886.DOC032). [3] Activate the Watch Alarm Key symbol is not visible; the watch alarm activator is switched to ON. The preset watch time is running downwards. The watch time settings are blocked know. [4] Activate the Watch Alarm when AUTOPILOT is active Key symbol is not visible; the watch alarm activator is switched to AUTO. The AUTOPILOT is switched to TACK or HEADING Control. The preset watch time is running downwards. The watch time settings are blocked know. 1--17

2 Servicing, maintenance and repair 2.1 Safety instructions Warning! Take care during maintenance and repair work: avoid touching live electrical connections. The applicable safety regulations such as VDE, VBG 4, OSHA 1919 and other appropriate safety standards must be followed. Warning! Maintenance and repair work may only be performed by trained and qualified personnel having knowledge of the national safety regulations for this type of equipment. Warning! The equipment can be damaged! Parts may only be replaced when the supply voltage is switched off. 2.2 Servicing and maintenance Servicing and maintenance are not needed for the NAUTOCONNING system. 1--18

aytheon Anschütz GmbH 2.3 epair 2.3.1 Explanation of the symbols or LED flashes or LED off or LED on 1--19

2.3.2 Control Unit Figure: 1--11 and the following table show the standard signals during trouble-- free operation. 1 Power Supply (+ 5 and + 15 VDC) 2 Alarm Manager 3 Alarm Slave 4 Power Supply Unit (24 VDC) 1 2 3 4 ON / OFF *) *) *) *) *) LED signalling when the Control Unit has to be in use Figure: 1--11: Signals on the Control Unit 1--20

aytheon Anschütz GmbH Power supply +5 V, + 15 V Pos 1 LED Color Standard Comment green +5V green +15V green --15V ON OFF ON Toggle switch ON for Control Unit ON OFF for Control Unit OFF Alarm Manager Pos 2 LED Color Standard Comment red green flashing Program is running Alarm Slave Pos 3 LED Color Standard Comment UN/FAULT flashing green Program is running Power supply 24 V Pos 4 LED Color Standard Comment green green 230 VAC 24V Emergency 1--21

If one of the LEDs behaves other than in the standard fashion, it is recommended as a first step to exchange the corresponding card (see chap. 2.3.2.1). If either the UN or the FAULT LED of one of the cards does not correspond to the standard signal, the first step is to perform a restart. Proceed as follows: Switch the device off (see ON/OFF switch, Figure: 1--11 ) and wait for about 5 seconds Switch the device on again. If the fault is not overcome in this way, appropriately trained service personnel should be called. 1--22

aytheon Anschütz GmbH 2.3.2.1 Exchanging the control unit pcbs -- Undo the cross--headed fastening screws and remove the cover. -- Undo the fastening screws of the connector on the front side of the pcb to be exchanged and pull out the plug. -- Loosen the pcb s two fastening screws, and pull the pcb out from the back--plane by pushing the levers apart, removing the pcb then in a forwards direction. -- Configure the new pcb The pcb configuration is software controlled (flash memory and program controlled) and has to be done by trained and qualified personnel only. Fastening screw Lever Lever Fastening screw Figure: 1--12 Control Unit, fastening points -- Insert the configured pcb and fasten it -- Plug the connector in and fasten it - Place the cover on and fasten it 1--23

NAUTOCONNING DISPLAY NCD NAUTOCONNING ALAM MANAGE NP 20xx Annex --1 ALAM TANSFE SYSTEM Block Diagram STATUS CONVETE aytheon Anschütz GmbH DV BUS ETHENET SWITCH ECDIS ADA STANDAD 22 COUSE EFEENCE SYSTEM SENSOS INPUT NMEA (option) WATCH ALAM ACTIVATO 12 SIGNAL UNIT or WATCH ALAM (TIME) ESET ALG BUS CONNING ALAM PANEL S422 230 VAC 24 VDC S485 S485 S422 CENTAL BIDGE PLACE ALAM PANEL used as CENTAL ALAM PANEL ALAM PANEL MFC *) or NAVIGATION DATA MANAGE max. 16 CLP (option max. 32 CLP) *) Multifunction Console STATUS 12 CONVETE or SIGNAL UNIT

Annex --2 ALAM TANSFE SYSTEM Block Diagram aytheon Anschütz GmbH