KH SERIES (PEN-WRITING SYSTEM)

Similar documents
AH3000 SERIES 180MM CHART PEN TYPE HYBRID RECORDER

JW SERIES. Three Phase Thyristor Regulator PSE-351

AL3000 SERIES 100MM CHART MULTI-POINT TYPE HYBRID RECORDER

PSE-369A. KL4000 SERIES 100mm chart DOT-PRINTING TYPE HYBRID RECORDER

PAPERLESS RECORDER COMMUNICATION FUNCTION (Ethernet)

PSE-367C. AL4000 SERIES 100mm chart MULTI-POINT TYPE HYBRID MEMORY RECORDER

Communications None RS-232C RS-422* RS-485* BCD Transmission output*/** (4 to 20 ma) E5AX- E5AX- L(M)A02 L(M)A03

MICROJET RECORDER (24-CHANNEL 180mm)

Safety Instructions MS 10B ALARM UNIT MS 10B ALARM UNIT. Used symbols. Always observe this information to prevent damage to the device

SHIMADEN DIGITAL INDICATORS

MICROJET RECORDER (180mm)

MICROJET RECORDER (180mm)

ES-LCD User Control SD Card Location

PSE-805A. AL4000 SERIES 100mm chart PEN HYBRID MEMORY RECORDER

RS485 MODBUS Module 8AI

20 Light Remote Annunciator

Operating Instructions High-spec Wired Remote Controller

GH10PA USER MANUAL. Program version 01 MANUAL FOR CONTROLLER FOR CONTROLLING CENTRAL HEATING BOILERS FIRED WITH PELLETS AND OATS

Technical Manual. Level Alarm Unit CARLA & WIDS

USER GUIDE. Paperless Humidity/Temperature Chart Recorder. Model RH520A 21.2 C 13:

INSTRUCTION MANUAL FOR RIKEN PORTABLE TOXIC GAS MONITOR

DPR-145 TEMPERATURE PROTECTION RELAY. DPR-145 User Manual V-2.0 ( ) PT100 INPUTS: 4 RELAY OUTPUTS: 4 RS-485 MODBUS PORT VDC SUPPLY -1-

WM3000 WIRELESS MODULES

INSTRUCTION MANUAL and DETAILED PRODUCT SPECIFICATION TRIPLEX PUMP CONTROL SYSTEM MODEL NUMBER CPC-3. M336 Rev F. November 21, 2000.

System Controller WV-CU151. Before attempting to connect or operate this product, please read these instructions completely

CONTENTS >> VACUUM OVEN. General Description. Shelves Detail. Vacuum Drying Oven. -Feature. -Specification. 350 Vacuum Drying Oven.

DEIF A/S. Technical Manual. Type EC-2 Engine Control Unit D. Technical Manual

EasyTronic III MANUAL SERVICE

SC-9 Controller INSTALLATION AND OPERATING INSTRUCTIONS. SC-9 Applications CONTENTS

24 VAC Intermittent Pilot Gas Ignition Control

CTT8 TEMPERATURE MONITOR DEVICE

MR SERIES CARD LOGGERS

Thermal Shock Chamber TSE 11

SM3000 Videographic Recorder. User Guide. Modbus (RTU) Communications Option

1 DOCUMENT REVISION CONTROL ELEMENTS... 9

MODEL: 47NLVT. Digital Panel Meters 47NL Series. POWER INPUT DC Power R: 24 V DC

Safety Temperature Limiter STL 50 Certified to DIN EN (replaces DIN 3440)

MO n : 12JMC rév A

Operator: Save these instructions for future use!

INSTRUCTION MANUAL A121APPX, AL121APPX & MV121 APPELLO Alarm Tone and Voice Annunciation Sounder

SCAN20 Series Gas Detection Controller

TECHNICAL MANUAL CVM 20 C 5005 CV/04-99 GB

Programmable Touchscreen Thermostats. Disconnect power before beginning installation.

Table of Contents. Page Quick Set-up Instructions 1. Theory of Operation 2. Specifications 3. TM 1003W Controls and Connections 4

FlameGard 5 MSIR HART

Hardware Instruction Manual. SR Mini HG SYSTEM. High-performance Multi-point Control System IMSRM15-E4 RKC INSTRUMENT INC.

SC-3 Controller INSTALLATION AND OPERATING INSTRUCTIONS FOR GAS-FIRED, OIL FIRED AND DUAL FUEL HOT WATER HEATING PLANTS. SC-3 Applications CONTENTS

INSTALLATION INSTRUCTIONS

Gas Detection System TOX ALARM DG2000-Garage

PSE-368. AH4000 SERIES 180mm chart MULTI-POINT TYPE HYBRID MEMORY RECORDER

ABB Instrumentation. Specifications. COMMANDER 150 Universal Process Indicator. the 1 /8 DIN indicator to match all your display requirements

CONVENTIONAL FIRE CONTROL PANELS FS 5100 and FS 5200

Process Alarm Solutions

Alarm system For oil-water separator

Fax (724) Main St.; P. O. Box 248 West Middlesex, PA IMPORTANT NOTICE

+ A B V B NO NC V COM PV PV

High Resolution Temperature Controller REX-F9000. Instruction Manual IM9000F01-E5 RKC INSTRUMENT INC.

Item Number Description Price. Accessories " Diesel/Water/Waste tank sender $ Battery temperature sensor $2.22

MODEL: 47NLDYT. [2] OPTIONS blank: none /Q: With options (specify the specification) Digital Panel Meters 47NL Series

INSTRUCTION MANUAL FOR MICROCOMPUTER BASED TEMPERATURE INDICATING CONTROLLER FCS-23A

Product Manual SZ1145

Micro-controller X C C1 C2 AL1 AL2 AL3. Model: PXR4/5/9. Operation Manual SEL PXR. ECNO:406e

Application Manual Loop Water Controller

MODEL P531, P532 AND P532UI FLAME MONITOR OPERATING MANUAL

INSTALLATION MANUAL. Refrigerant stop valves kit EKRSVHTA

SR Mini HG SYSTEM. High-performance Multi-point Control System. SR Mini HG SYSTEM. Hardware Instruction Manual IMSRM15-E6 RKC INSTRUMENT INC.

M2000 Engine Controller

CN-6000 Series. Features. Ordering information CN C1. Part descriptions. 5 ( key: Used to enter parameter set mode, move to parameters,

CN-6000 Series. Features. Ordering information CN C1. Part descriptions. 5 ( key: Used to enter parameter set mode, move to parameters,

Advanced Ultraviolet Burner Controller

Series Digital Controller Instruction Sheet

Comfort Thermostat Function

DH400. Accessories. NOTE: Set up for this sensor should be performed by an AAADM-certified installer.

Communications* None RS-232C RS-422 RS-485 BCD Transmission output** (4 to 20 ma)

IMR Environmental Equipment, Inc Central Ave. St. Petersburg, FL Phone:

CentaurPlus C27 Series 2 User Operating Instructions

SA100L. General Description. Features. Temperature Limit Controller SA100L. Simple Mounting on DIN Rail. Over/Under Temperature Protection

AUR300C, AUR350C. Advanced Ultraviolet Burner Controller

DIGITAL INDICATING CONTROLLER FCS-23A INSTRUCTION MANUAL

Product Manual SZ1144

LD5-TMR and LE5-TMR Large Digit Timer Display Operation and Instruction Manual

MULTIGUARD MULTIGUARD USERS MANUAL TYPE S3/240W 26/01/2010

Fire Burglary Instruments Inc. XL-2G Gold Control/Communicator Installation Training Seminar Rev. 5/96

FLOW CONTROLLER TYPE S/601

FOR MORE INFORMATION AND PRODUCTS, VISIT: USER MANUAL TO REMAIN IN VEHICLE

SERVICE INSTRUCTIONS FOR. Fire Alarm System MINI-2000

SA200. General Description. Features. Temperature Controller SA200. Self-Tuning Algorithm. Close Vertical or Horizontal Mounting

SAPCON SMART-SSI. Continuous Speed Indicator. Users Manual. . Introduction. . General Description. . Principle of Operation. .

MODEL: 47LCT. Digital Panel Meters 47 Series. [3] DISPLAY COLOR R: Red YR: Orange G: Green BG: Bluegreen B: Blue W: White

QA16 Addressable System

TECHNICAL BULLETIN [ 1/9 ]

DICKSON KT6 DICKSON. Temperature Chart Recorder. Specifications. Product. Display Symbols. Information & Operating. Contents:

Operating Manual. Series Touchscreen Programmable Demand Control Thermostat. UtilityPRO TM

Interactive Fire Control Panel IFS7002 four signal loops Instruction Manual

UPM I. Unit Protection Module. Installation and Operation Manual (2015/06)

MANUAL FOR MJK LIQUID SAMPLER 780

1.7 A-ISOMETER IRDH575. RoHS. Dipl.-Ing. W. Bender GmbH & Co. KG Londorfer Str Grünberg Tel.: Fax:

GMA 301. Operation Manual. Worldwide Supplier of Safety Solutions. Part Number

OJ Waterline control system

User s. Manual) Model VJS7 Potentiometer Converter (Multi-function) (Isolated Single-output and Isolated Dualoutput

Transcription:

INST. No. INE-335 KH SERIES (PEN-WRITING SYSTEM) MOLTEN STEEL TEMPERATURE RECORDER

CONTENTS 1. Application 1 2. Model number 1 3. Additional specifications 2 3-1 Recording and printing functions 2 [1] Date printing 2 [2] Immersion recording function 2 [3] Alarm printing 3 [4] List printing 3 3-2 Display function 4 [1] Maximum temperature display 4 [2]Disconnection display 4 [3]Status display 4 3-3 Output function 5 [1]No. of output points and function 5 [2]Relation between output conditions and operation 6 3-4 Setting function 6 [1]Setting flow chart 6 [2]Setting operation method and setting range 7 4.Deletion specification 7 4-1 Digital printing functions 7 4-2 Setting-operating functions 7

1. Application This manual adds exclusive specifications as molten steel temperature recorder to the specifications of hybrid recorder KH series. It contains the additional specifications and operation methods. The specifications other than those of the molten steel temperature recorder are common to those of the standard product. Please read the instruction manual for standard product accordingly when operating this recorder. For safe use, please read Important information and Cautions on safety without fail, in particular The terms in this manual are also common to those of the instruction manual for standard product. If you have the option communication interface, please read the separate [Instruction manual for communication interface], too. 2. Model number K H 1 E 0 0 - N E 1 Communication interface (option) N : None A : RS-422A R : RS-232C S : RS-485 Molten steel temperature recording specifications E : External drive (option) 1: Not provided 2: Provided 1

3. Additional specifications 3-1 Recording and printing functions [1] Date printing Date (year, month, day) and time are printed on the recording paper when turning on the power supply. 22 ****POWER ON 95/07/08 08 : 48 **** [2] Immersion recording function The instrument starts recording when a measuring temperature input exceeds the preset recording start temperature and stops recording when the recording time has passed its preset time. It deflects the pen to the lower limit and prints the maximum measuring temperature. 5 PEAK TEMP = 1605 CHART SPEED = 400mm/M **** EMERSION END 95/07/08 09 : 14 **** 4 3 [It takes about 4 minutes to print data after recording ends. The following measurement cannot be done during printing. If printing is not necessary, turn off 6 of dip switch SW1 mounted below the front operation keys. (This switch is set to ON at the delivery time) 2

[3] Alarm printing Max. 2 higher-limit alarm points can be set to a temperature input during immersion recording, and alarm decision results are additionally printed when printing the maximum temperature. Data of the maximum temperature are held up to the next measurement. Occurrence of the 1st alarm Occurrence of the 2 nd alarm 19 PEAK TEMP = 1753 AL1 AL2 CHART SPEED = 400mm/M **** EMERSION END 95/07/08 09 : 14 **** [4] List printing Set values relative to the molten steel temperature recording are printed when operating the front keys. 23 M1 START TEMP = 1100 M2 RECORD TIME = 5SEC CHART SPEED = 400. 200. 100mm/M **** EMERSION LIST 95/07/08 09 : 14 **** 3

3-2 Display function [1] Maximum temperature display The maximum temperature during immersion recording can be displayed by the front key operation. Turning on the power supply Initial display (about 3sec) Present value display Maximum temperature display (0 after power supply has been turned on) Time display Data display mode CH DATA A residual recording time is displayed at CH part during immersion recording. [2] Disconnection display If an input disconnection failure is detected, the present value is displayed as shown below to inform of the input disconnection failure. CH DATA [3] Status display The front green LED (PW) lights during immersion recording. 4

3-3 Output function The alarm output function being provided as an option in the standard product is added as a standard specification in the molten steel temperature recorder to output the operating conditions of the molten steel temperature recorder. [1] No. of output points and function No. of output points: 6 points H-C-L S p e c i f i c a t i o n s: No-voltage contact (relay) Contact capacity; 100V AC, 0.5A (resistive load) 30V DC, 1A (resistive load) Operation time; Approx. 2msec Recovery time Approx. 1msec (excluding contact bound time) Minimum application load; 10µA, 10mV DC Caution: A relay output is designed to apply to status monitoring, etc. Don t apply it to any control of important facilities or control of facilities being attended with danger. F u n c t i o n : Contact 1 H-C is shorted when the 1 st alarm occurs and H-C is open when it does not occur. Contact 2 H-C is shorted when the 2 nd alarm occurs and H-C is open when it does not occur. Contact 3 H-C is shorted when the 1 st alarm occurs during immersion recording and H-C is open when it does not occur during immersion recording. Contact 4 H-C is shorted when the 2 nd alarm occurs during immersion recording and H-C is open when it does not occur during immersion recording. Contact 5 H-C is shorted when the input is disconnected and H-C is open when the input is normal. Contact 6 H-C is shorted during immersion recording and H-C is open when immersion recording is not done. Contacts 1 and 2 are operated by alarm decision results to the present temperature input. In case of contacts 3 and 4, the alarm occurrence conditions during immersion recording are held up to the next recording. 5

[2] Relation between output conditions and operation The relation between contact 1 ~ 4 & 6 relay conditions and the operation is as shown below. 2 nd alarm level 1 st alarm level Input Contact 1 Recording start temperature Contact 2 Contact 3 Contact 4 Contact 6 3-4 Setting function [1] Setting flow chart Set values necessary for recording the molten steel temperature can be set by front keys according to the following procedure. Display mode Longer than 2sec. Longer than 2 sec. or no keying operation for longer than 1min. Molten temperature setting ENT ENT ENT ENT Recording start temperature setting Recording time setting Molten steel temperature recording setting List printing operation Setting mode 6

[2] Setting operation method and setting range Setting/operation items Setting operation method Setting range At the delivery time Recording start temperature setting Alarm value setting in instruction 0~1800 1200 Recording time setting manual for standard product 3~ 60 12 Molten steel temperature set values list printing Bring the cursor by and execute by ENT or stop by. For details of the setting method, refer to the instruction manual for standard product. 4. Deletion specification 4-1 Digital printing functions Certain functions out of the following digital printings in the standard product are deleted. Kinds Functions Present specifications Fixed time recording Prints data every fixed internal. Not provided Scale printing Prints a recording scale every fixed internal. Not provided Alarm printing Prints the alarm contents when an alarm occurs and it is reset. Not provided Time and time line printing Prints time and time line every hour sharp. Not provided Chart speed printing Prints the present chart speed at the timing of time printing. Not provided Setting change mark Prints characters showing the change contents when changing a set value. Not provided For details of the functions, refer to the instruction manual for standard product. 4-2 Setting - operating functions Certain functions out of the following setting - operating functions in the standard product are deleted. Kinds Functions Present specifications REC ON key Turns on or off the recording when operating this key. Provided Data print Prints data when operating this key. Not provided Chart speed setting Sets the chart speed. Max. 3 speeds can be set. The setting range is changed to 10 ~ 400mm/M only. Provided Alarm setting Sets the alarm decision conditions. Provided Alarm setting copy Copies alarm set values. Provided Time setting Sets the time. Provided Fixed time recording Sets data printing conditions at a fixed time. Not provided Skip setting Deletes display and recording every channel. Not provided Chart speed change by external drive Selects 3 speeds by the combinations of 2 external drive contacts. Provided For details of the functions, refer to the instruction manual for standard product. 7

32-8, KUMANO-CHO, ITABASHI-KU, TOKYO 173-8632 Telephone: 81-3-3956-2171 Facsimile: 81-3-3956-0915