SPECIFICATIONS HYLYTR. with DOUBLE SLOT OPTICS

Similar documents
NOVENTA NV3.5 Suspended, Surface, Wall, Recessed LED

HBEAM 1.25 PRE-DESIGNED HB1.25 PRE-DESIGNED STRAIGHT SECTIONS (2FT - 8FT)

BAS SFP22 Edge-lit LED Panel

RECESSED T-Bar & Drywall

MEDLEY A. RoHS COMPLIANT INTERIOR - INTEGRAL POWER SUPPLY WHITE LIGHT & STATIC COLORS SHAPING THE EXPERIENCE OF LIGHT

M60 LED Recessed Wet Location

LUMINAIRE ID SIZE CENTER OPTICS SIDE OPTICS LIGHT SOURCE CRI LUMEN PACKAGES COLOR TEMP. VOLTAGE. LED - high performance LED 80-80CRI 90-90CRI

Etch 2' x 2' Recessed LED

FPLHB - Fidelux Premier Linear Highbay

M100 My White LED Direct Tunable White

M100 LED Direct/Indirect

RECESSED Spec Guide. up to 111 lm/w performance

Catalog # Project. Comments. Prepared by. Warranty Five year warranty

M-LED for 4 Technical Ceilings Recessed Linear LED for 4 Technical Ceiling Systems

ZipTwo LED 707. Micro-profile interior direct lighting for open office, wall wash and wall graze applications. Spec Guide

RECESSED - WITH StepLens OPTION

LED Lighting Product Guide. Winter A portfolio of industry-leading solutions that are changing the way we look at light.

VESICA LINEAR SUSPENDED VES L

Product Specifications

DRD5S & SurfaceFrame Alt/EM Surface Mount LED Downlight

Grüv Flare Regressed. Recessed Linear LED

M36 My White LED Direct

SURFACE Spec Guide. up to 105 lm/w performance

light ACL9 ANATOMY PERIMETER FOCUSED INSTALLATION SLEEK & STRONG

LED FLAT PANEL EDGE LIT MLFP SERIES G2

LED High Bay. 150W LED High Bay GLC-ANHB-150W-1. PERFORMANCE LED Chip Lumen Output (IES) Power Consumption Efficacy (IES) Beam Angle

Evolution EXWW RECESSED LINEAR WALL WASH LUMINAIRE

Grüv Flare Regressed. Recessed Linear LED

LED HIGH BAY LINEAR ECO SERIES

LUX PENDANT DIRECT/INDIRECT

TROFFER RETROFIT KIT (TRK)

Claude Indirect Wall WALL

Type: Project : Luminaire characteristics: Source: Lumen maintenance: Optics: Material: Mounting: Electrical: Finish: Weight:

ArcLine Recessed LED luminaire

3.75 Gyro Shift Multiples Single Head

IBLED SERIES 4' PROJECT: FEATURES AND SPECIFICATIONS LINE DRAWING

Metalux SWLED LED. Type. Catalog # Project. Date. Comments. Prepared by

Housing. Mounting. Warranty. Listing

Truss Surface SURFACE

Excellence in LED Lighting. e-solis Edge Lit LED Panels.

*REPRESENTS 3500K/80CRI 2 FT 4 FT 6 FT 8 FT 2 FT 4 FT 6 FT 8 FT *REPRESENTS 3500K/80CRI LINEAR

4 LED Recessed Adjustable. Energy efficient, stylish downlighting for residential and commercial applications

DRD5S & SurfaceFrame Alt/EM 18" Linear Surface Mount LED Area Light

Max 4 Flush Lens RECESSED

SOL CROSS SECTION. PENDANT Spec Guide. Page 2 of Rev. JUNE18-1

AVAILABLE THROUGH GRAINGER. LED Fixtures

LED ECO PANEL.

CLM 422 Series LED Ceiling Luminaire Module - 45Watt

SDL4 LED Strip Diffused Lens

BAS SDL8' LED Strip Diffused Lens

Lumination LED Luminaires

New LED Product Offerings

LED Lighting Product Guide. Spring A portfolio of industry-leading solutions that are changing the way we look at light.

WARRANTY LED ECO PANEL.

The only lighting product that is designed, approved, and patented to replace the cross members in a suspended grid ceiling system.

Albeo LED Luminaire. Heavy Industrial Low Bay Lighting. (ALR1 - Series)

Dimensions (111mm) 3 (76mm) (111mm) (48mm)

Recessed. DuaLED 2x , 2700, 3000, 3400, 3800, or 4400lm

LIGHTING WITHOUT LIMITS. Manufacturers of LED and Fluorescent Luminaires

LED HIGH BAY LINEAR HL SERIES

APPLICATIONS SPECIFICATION FEATURES ORDERING. Project: Notes: Catalog #: Large Outdoor Spaces. Swimming Pools. Shopping Malls. Large Indoor Spaces

Dimensions (111mm) (111mm) 3 (76mm)

Catalog # Project. Comments. Prepared by. 23-3/4" [603mm] LAMP CONFIGURATIONS. 3-1/4" [83mm] X=2-7/16" [62mm] Y=2-1/2" [64mm] CEILING COMPATIBILITY

RLN Recessed LED luminaire

Millenium Os. Luminaire LED. For Stairwells and Public Spaces. Designed and manufactured in the USA. High Abuse Motion-Activated Lighting Product

EarthTronics products. About us. Where efficiency meets innovation. T5 & T8 Linear. Founded in 2007, EarthTronics, Inc. is a Michigan based

BeveLED Cylinder LBRP6 Surface

CIRRUS CEILING WALL GRAZER WITH REMOTE POWER

RTC Recessed LED center basket

Highbay Linear LED Series Flat Profile Design

Step-Dimming and/or 0-10v Dimming Drivers Electro Galvanized Steel Welded Construction. Photocell Sensor - On/Off Stainless Steel Fasteners Standard

Essentials Series 4.0

BAYMAX TM LED LINEAR HIGHBAY FIXTURE BLHT SERIES

Qty: L lm/12.6W K. DC3 Lutron 3-Wire. DMD eldoled DALI. DC2 5 Lutron 2-Wire

DIMMING 0-10V Continuous

Recessed LED Wall/Slot SAE 202

LM Series LED Architectural Downlighting HIGH LUMEN OUTPUT RECESS / SURFACE MOUNT GREEN ENERGY EFFICIENT LIGHTING

FULL BLEED APPLICATION SHOT RENDERING

Product Specifications MaxLumen MRI LED Diffused Lighting

Capella 2. Project Name. Construction. Optical System. Product Applications. Housing and lens frame are constructed from heavy-duty low

OLS-DI-LED LED ARCHITECTURAL LINEAR SYSTEM. Warm Dim with Smart Dim Technology LED ARCHITECTURAL SUSPENDED LINEAR DIRECT/INDIRECT SYSTEM

OLS-R-LED LED ARCHITECTURAL LINEAR SYSTEM. Warm Dim with Smart Dim Technology LED ARCHITECTURAL RECESSED LINEAR DIRECT SYSTEM 2" 4"

Ivalo Lumaris. LED Linear Lighting. High quality, even lines of illumination and guaranteed LED compatibility with 1% Lutron dimming IVALO COLLECTION

Continuous Light, Endless Design

Ivalo Lumaris LED Linear Lighting

Product Specifications MaxLumen MRI LED Diffused Lighting

lumenalpha downlight Specification Sheet

LED Tri-Proof. LED Tri-Proof. T: +44 (0) E:

Fino. Asymmetric Wall Mount Indirect LED

ERIA SQUARE. ERIA with Square Open Trim JMA ST ERIA HOUSING JMA SH COLOR OPTIONS. Available in Satin White or Satin Black finishes

Hornet HP. Semi-Recessed 4-Light Square Multiple

Ivalo Lumaris LED Linear Lighting

Product Overview. Fixture Type. Performance Chart. Wattage. Electrical Data 23W System Watts Amps

Ivalo Lumaris LED Linear Lighting

ACL 4 ANATOMY. COVER UP Partially diffuse dust cover enhances indirect lighting performance and preserves LED lifespan. 1.87

Modular & linear architectural lighting for residential and commercial environments.

2200TD-3000TD Dim to Warm* 2700T-6500T Tunable White* *Must be ordered with D05 or DS5 Driver options; excludes 2' and 3' lengths

DHL-LP-LED Low Profile LED Linear High/Low Bay

Project Name. Date. Cat. Number. Type

Linea 1.5. Linear Direct Wall Wash LED

Transcription:

HYLYTR with DOUBLE SLOT OPTICS (HYWG) Recessed, Perimeter, Mud-In LED MULTI-GRAZER (HYMG) Surface LED SHOWCASER (HYSC) Recessed, Suspended LED HYWGR HYMG HYSCS HYMG HYWGRP Find additional images and information at alwusa.com/hylytr

1. BASE MODEL HYWGR HYWGRPT 1 HYWGRPS 1 HYWGRMUD MULTI-GRAZER HYMG/CS HYMG/FS SHOWCASER HYSCR HYSCS/CS HYSCS/FS Recessed for T-grid and slot ceilings, 2 angle Recessed perimeter-mount for T-grid ceilings, 2 angle Recessed perimeter-mount for slot ceilings, 2 angle Recessed mud-in for drywall ceilings, 2 angle Page 2 of 8 Surface, (2) 4" arms rotate for wall or ceiling grazing, (2) JBox2 canopies (1) curved shroud Surface, (2) 4" arms rotate for wall or ceiling grazing, (2) JBox2 canopies, (1) flat shroud Recessed for T-grid or slot ceilings, 0 angle Suspended, 0 angle with (2) curved shrouds Suspended, 0 angle with (2) flat shrouds 1 Wall-to-wall, continuous row installation recommended Type: 2. RUN LENGTH/ SIZE Run Length 2 (enter total linear length, ex: 2, ex: 20, etc.) 2 Due to Hylytr's wide lateral distribution, a continuous row may not be necessary in grazing applications to achieve relatively uniform illumination across the top of the wall. Multiple shorter individual units spaced appropriately are often suitable. Please consult SPECIFICATION APPLICATION GUIDE (pg. 3) prior to specifying. All fixture lengths are nominal. 3. LAMPING Pair lamping with CCT (where applicable), ex: MED/2700K LOW 6 W/lf, 1817 peak cd/ft, 303 cd/w, 237 lm 2700K 3000K 3500K 4000K MED 10 W/lf, 3633 peak cd/ft, 363 cd/w, 474 lm 2700K 3000K 3500K 4000K HI 13.5 W/lf, 5450 peak cd/ft, 401 cd/w, 711 lm 2700K 3000K 3500K 4000K MAX 36 W/lf, 16349 peak cd/ft, 454 cd/w, 2133 lm 2700K 3000K 3500K 4000K 4. DRIVER Pair driver with dimming level (where applicable), ex: 0/10V/1% 0/10V/ 3,4 0-10V dimming 1% Dimming to 1% 0% Premium dimming to 0% DALI 3,4 DALI dimming to 0% DMX 3,4 DMX dimming to 0% ECOSYS1 3,4 Lutron Hi-lume 1% EcoSystem, constant current or constant voltage ECOSYS5 3,4 Lutron 5-Series 5% EcoSystem, constant current 3 Drivers in recessed models (HYWGR, HYWGRP, HYWGMUD, HYSCR) are semi-integral attached atop fixture, but may be remoted in applications with shallow plenum heights. Drivers in surface-mount (HYMG) and suspended (HYSCS) models as well as in ALL individual 1' luminaires are always remoted. 4 Driver specs provided upon request to assist with control system integration. Consult factory.

5. FINISH AL BK BRS SV WH WH/AM RAL/ Standard, natural Ultimatte aluminum Black powdercoat Brass metallic powdercoat Silver powdercoat White powdercoat White antimicrobial powdercoat for healthcare environments Specify RAL powdercoat code (ex: #RAL/3003) Page 3 of 8 Type: 6. VOLTAGE UNV Universal voltage 347 5 347 volt 5 Driver options may be limited with 347 voltage. Consult factory. 7. ADDITIONAL OPTIONS NONE COMBO ENLGHT/ 6,7 OS/ 7 PH/ 7 SB None Combo 4.5" canopies with both power and suspension mount hardware (HYSCS only) Enlighted 0-10V remoted smart sensor (occupancy, daylight, networking and more) 0-10V remoted occupancy sensor (indicate total quantity, ex: OS/4) 0-10V remoted photocell/daylight sensor (indicate total quantity, ex: PH/4) Seismic bracing (HYSCS only) 6 Enlighted Gateway and Energy Manager (by others) plus programming required. Learn more at enlightedinc.com. 7 Select quantity of 1 for every 8 ft. (ex:enlght3 for a 24' fixture run; OS4 for a 32' fixture run) GRAZING EFFICIENCY Why is the performance of Hylytr measured in candelas and cd/w rather than lumens and LM/W? For grazing applications, the goal is to evenly illuminate the wall or ceiling being grazed while highlighting the surface s textures. A long, narrow beam that runs almost parallel to the grazed surface (as Hylytr provides) is ideal. Typical grazers emit a relatively wide beam (blue line). Hylytr, by contrast, produces a narrow, almost laser-like, beam (green line) that allows for spill-free illumination. Candelas the lighting measurement that describes how far a source "reaches" is the most important metric in grazing applications. A traditional fluorescent grazer has an effiicency of 55 cd/w, while a typical LED grazer may achieve double that at 110 cd/w. Hylytr, by contrast, greatly out-performs both reaching 300-400+ cd/w in a typical application. Lumens, on the other hand, is a measure of distributed intensity where higher values register at horizontal light outputs nearest to 90. This is why grazers and directional lighting, in general, are not included in DesignLights Consortium (DLC) nor other regulatory registries. Grazing Efficiency measures the ability of light to reach long distances using less energy.

SPECIFICATION APPLICATION GUIDE Page 4 of 8 LUMINAIRE PERFORMANCE APPLICATION OPTIONS CANDELA INTENSITY AND ENERGY USE LUMINAIRE SEGMENT LENGTH 1' 2' 4' LED LAMPING OPTION LOW MED HI MAX 1,817 cd 6 W 3,633 cd 10 W 5450 cd 13.5 W 16,349 cd 36 W 3,634 cd 12 W 7,266 cd 20 W 10,900 cd 27 W 32,698 cd 72 W 7,268 cd 24 W 14,532 cd 40 W 21,800 cd 54 W 65,396 cd 144 W RECESSED + MUD-IN RECESSED PERIMETER SAMPLE GRAZING APPLICATIONS 7 WALL MOUNT CEILING MOUNT 10 10 TEXTURED SURFACE 1' Fixtures - 1' Spacing - MED APPLICATIONS: Offices, Homes, Schools, etc. SMOOTH SURFACE Continuous Row - LOW APPLICATIONS: Offices, Homes, Schools, etc. WALL MOUNT CEILING GRAZER CEILING MOUNT CEILING GRAZER 13 14 15 15 RECESSED SHOWCASER SUSPENDED SHOWCASER TEXTURED SURFACE 2' Fixtures -1' Spacing - MED APPLICATIONS: Lofts, Offices, Homes, Schools, etc. SMOOTH SURFACE Continuous Row - LOW APPLICATIONS: Lofts, Offices, Homes, Schools, etc.

SAMPLE GRAZING APPLICATIONS (CON'T) 26 28 Page 5 of 8 20 20 TEXTURED SURFACE 4' Fixtures - 1' Spacing - HI APPLICATIONS: Atriums, Warehouses, Theaters, Convention Centers, Cathedrals, Airports, etc. SMOOTH SURFACE Continuous Row - MED APPLICATIONS: Atriums, Warehouses, Theaters, Convention Centers, Cathedrals, Airports, etc. 28 60 H F v 45 45 TEXTURED SURFACE 4' Fixtures - 4' Spacing - MAX APPLICATIONS: High-Bay Storehouses, Atriums Cathedrals, Stadiums, Arenas, etc. SMOOTH SURFACE Continuous Row - 900 MAX APPLICATIONS: High-Bay Storehouses, Atriums, Cathedrals, Arenas, etc.

MOUNTING & DIMENSIONS Page 6 of 8 7 3 8" 5 3 16" 7" 5 3 16" 7" 6" 7 13 16" 6" 7 13 16" 3 7 16" 4" 3 7 16" 3 8" 3 1 4" 1 1 2" 3 8" 3 1 2" 1 1 2" 2 5 16" 4 7 8" 5 8" RECESSED TGRID HYWGR RECESSED SLOT HYWGR PERIMETER TGRID HYWGRPT PERIMETER SLOT HYWGRPS DRYWALL HYWGMUD MULTI-GRAZER 4 1 2" 4 1 2" 4 1 2" 4 7 16" 5 7 8" 4 1 2" 4 7 16" 5 7 8" 4 7 16" 5 7 8" 4 7 16" 5 7 8" WALL-MOUNT HYMGW/(CS) WALL-MOUNT CEILING GRAZER HYMGW/(CS) CEILING-MOUNT HYMGC/(CS) CEILING-MOUNT CEILING GRAZER HYMGC/(CS) SHOWCASER 5 3 16" 4 7 16" 5 7 8" 4 7 16" 7 1 4" 5 3 8" 7 3 16" 5 3 8" 2 11 16" 3 1 16" SUSPENDED FLAT SHROUD HYSCS/FS SUSPENDED CURVED SHROUD HYSCS/CS 2 3 16" 3 9 16" 4" RECESSED TGRID HYSCR 2 3 16" 3 9 16" 4 3 16" RECESSED SLOT HYSCR

OPTICS Proprietary, patent-pending Double Slot Optics occlude stray, remnant light emissions to produce sharp-edged, narrow-beam and glare-free illumination that reaches distances of up to 60'. The optics chamber doubles as the luminaire's lens- free fixture housing. OPERATING TEMPERATURE Page 7 of 8 Luminaire should be installed and operated ONLY in environments where the ambient temperature ranges from -4 F (-20 C) to 122 F (50 C). Operating the luminaire in environments outside the listed temperature range voids the warranty AND may damage the product or adversely impact lamp life, lumen output and color consistency. EMERGENCY Secondary beam spill is clipped by two sets of slot edges within the optics chamber. A clean, sharp primary beam of light is then emitted through a narrow, lensless opening. The deep recession of the LEDS in the optics chamber provides glarefree illumination at critical glare angles. Luminaires can be wired for emergency circuit and/ or emergency battery backup. Consult factory for details. AESTHETIC SHROUDS Optional aesthetic shrouds (1) surface-mount (HYMG) and (2) suspended (HYSCS) only cover the linear slots in the base housing which are otherwise used for mounting in other models. The shrouds are constructed of the same aluminum as the housing and match finish choice. FLAT FS CURVED CS 45 85 SUSPENSION HARDWARE (HYSCS ONLY) HOUSING 100% recyclable, extruded architectural grade T6063 T5 aluminum alloy with.08" minimum wall thickness. ELECTRICAL LED drivers are Class 2. LED light engine is LM-80 compliant with 90+ CRI. ETL listed. L 80 at 60,000 hours. CEILING HARDWARE (1) 4.5" canopy per power feed location, (1) bullet mount, (1) 8' aircraft cable and (1) 2" canopy (for use with T-bar mounting) per suspension point COMBO CANOPY Choose COMBO to specfiy 4.5" canopy at feed location with power and cable suspension mounting

WALL HARDWARE (HYMG ONLY) 2 1 4 " (2) 4" arms rotatable arms, (2) 2.25" JBox2 wall plate canopies with integral splice box. 3 1 4 " REMOTE DRIVER INFO MAXIMUM REMOTE DRIVER DISTANCE* Page 8 of 8 Wire Gauge (AWG) Distance FINISH Standard finish is "Ultimatte" aluminum a smooth, clean and durable finish achieved from a deepetch and two-step clear anodizing process. White, black, silver, brass and color RAL powdercoat options also available. For healthcare environments, a white antimicrobial finish (WH/AM) is also an option. 12 120 ft. 14 80 ft. 16 50 ft. 18 30 ft. * Applicable to 0/10V/10% drivers only. Consult factory for additional driver information. ALUMINUM AL WHITE WH & WH/AM BLACK BK * ALW provides 18 AWG power feed cable from luminaire to canopy. Maximum distance includes length of power feed cable suspended from remote driver to luminaire. Ex: 30' max length - 3' suspension = 27' available to run from remote driver. to building power. SILVER SV BRASS BRS COLOR RAL