NHB High Efficiency Condensing Boilers

Similar documents
NCB-E Combi-boilers. The first high efficiency condensing combi boilers that can do it all... for larger homes

NCB-E Combi-boilers. The first high efficiency condensing combi boilers that can do it all... for larger homes

NPE-A and NPE-S Condensing Tankless Water Heaters

NPE-A and NPE-S Condensing Tankless Water Heaters

NPE-A and NPE-S Condensing Tankless Water Heaters

NPE-A and NPE-S Condensing Tankless Water Heaters

The Leader in Condensing Technology. Navien Home Energy Saving Solutions

NPE Series Condensing Tankless Water Heaters

Navien boilers for home heating

Commercial Tankless Rack System

Commercial Tankless. Rack System TANKLESS WALL MOUNT LIGHTWEIGHT EXPANDABLE REDUNDANCY EASY FIELD INSTALLATION EASILY INTEGRATE STORAGE WARRANTY

Air-Fuel Ratio (AFR) Sensor Exhaust & Water Temperature Safety Control Overheat Cut-Off Fuse

Commercial Tankless Rack System

COMMERCIAL-GRADE RESIDENTIAL GAS WATER HEATERS

Residential Gas Tankless Water Heater

Tankless Condensing High Efficiency Water Heaters with Built-In Pump

SAFETY FEATURES: Air-Fuel Ratio (AFR) Sensor Exhaust & Water Temperature Safety Control Overheat Cut-Off Fuse

Raptor 320HB & 399HB Submittal Sheet

SAMPLE SPECIFICATION FOR RIELLO ARRAY MODULATING BOILER

Commercial Tankless Rack System

Tankless Condensing High Efficiency Water Heaters

SOLID. STATE. Commercial Tankless. Rack System TANKLESS WALL MOUNT LIGHTWEIGHT EXPANDABLE REDUNDANCY EASY FIELD INSTALLATION EASILY INTEGRATE STORAGE

iq251, Gen II Submittal Data

Residential/Commercial Gas Condensing Tankless Models

Commercial Tankless Rack System

MULTI-LINK UP TO 20 UNITS COMMON VENT UP TO 8 UNITS COMPLIES WITH LEAD FREE STANDARDS SAFETY FEATURES:

Date: Bid Date: Model: i200 i200p. Project Name: Project #: Location: Fuel Type: Natural Gas Propane. Engineer: Contractor: Key Features.

Warmth, efficiency, and total peace of mind.

NAVIEN AMERICA INC FITCH AVENUE IRVINE, CALIFORNIA, USA

i200, Gen II i250, Gen II Submittal Data

96% AFUE Efficiency CONDENSING RESIDENTIAL GAS BOILERS CONTROL WITH ADVANCED USER FEATURES MODELS FROM 80,000 TO 285,000 BTU/HR

Bosch Buderus SSB255/399/512 Stainless Steel Condensing Boiler

Utica Boilers MAC Submittal

The WCGH High Efficiency Commercial Water Heater with Storage Tank

95% AFUE Efficiency CONDENSING RESIDENTIAL GAS BOILERS REMOTE CONNECT CAPABLE CONTROL WITH ADVANCED USER FEATURES MODELS FROM 80,000 TO 285,000 BTU/HR

Endless water. Zero waste. Commercial. High-output, on-demand water heaters. iq Series, Gen II

10 : 1 Turndown Ratio

iq751/iq1001/iq1501 Specifications (Floor-standing units)

Bid Date: Date: Project Name: Project #: City/St/ZIP: Fuel Type: Natural Gas Propane. Engineer: Factory Option: Contractor: Key Features.

96.2% Thermal Efficiency HIGH EFFICIENCY COMMERCIAL BOILERS CON X US REMOTE CONNECT. MODBUS AND BACnet MSTP PROTOCOL

iq1001, Gen II Submittal Data

7 sizes: 55,000, 80,000, 110,000, 155,000, 199,000, 285,000 & 399,000 Btuh. One of a kind design from the inside, out!

Crossover. Hybrid Water Heater HIGH EFFICIENCY. Advanced Heating & Hot Water Systems. w w w.htproducts.com

Suggested Specifications Prestige Excellence 110

Qualifies for up to $ 1500 Energy Tax Credit! CONDENSING RESIDENTIAL GAS BOILERS CONTROL WITH ALL NEW, ADVANCED USER FEATURES

ULTRA SERIES 4 HIGH EFFICIENCY CONDENSING BOILER

Advanced Heating and Hot Water Systems

ULTRA SERIES 4 HIGH EFFICIENCY CONDENSING BOILER HIGH EFFICIENCY CONDENSING BOILER

Date: Project #: Engineer: Prepared By: Bid Date:

Service Manual. Condensing Boiler. Getting Service

Residential/Commercial Gas Condensing High Efficiency Tankless Water Heaters

Weil-McLain part numbers are found in Weil-McLain Boilers and Controls Repair Parts Lists.

Crossover. Hybrid Water Heater. High Efficiency. Advanced Heating & Hot Water Systems.

Heating Systems Company LAARS INTRODUCES. The MASCOT LX. A Boiler. An All-in-One Answer to Your Home Heating and Hot Water Needs

TANKLESS PRODUCT GUIDE CANADA TANKLESS PRODUCT GUIDE. A. O. Smith

A Better Boiler Just Got Better. Better Boilers. New Size Available. Express Setup. Load Status. User Setup. Installer Setup. Diagnostics.

Up to 94.6% Thermal Efficiency HIGH EFFICIENCY COMMERCIAL CONDENSING BOILERS OPERATING CONTROL FEATURING A BUILT-IN CASCADING SEQUENCER

DIVISION WALL-HUNG STAINLESS STEEL HEATING BOILERS

Gas-Fired Condensing Boilers A Green Start To Space & Water Heating

Phantom-X 399C/500C. Residential High Efficiency Gas Boilers PHNTM399C, PHNTM500C Submittal Sheet. Wholesaler Job Name Mechanical Contractor

EVERGREEN HIGH EFFICIENCY CONDENSING BOILER

Gas-Fired Condensing Boilers A Green Start to Space & Water Heating

HIGH EFFICIENCY CONDENSING GAS COMBINATION BOILERS FIRE TUBE COMFORT DONE RIGHT. 95% AFUE Efficiency. f ive. nt y. pa rts w a

AFUE 95% Heating Input 50,000 to 200,000 Btuh

Highlights MBH 95% efficiency ENERGY STAR Qualified Low NOx emissions Space-saving design. 95% Efficient. Modulating Technology

EVERGREEN HIGH EFFICIENCY CONDENSING BOILER EASY HEAT, EFFORTLESS COMORT

HIGH EFFICIENCY RESIDENTIAL BOILERS FIRE TUBE A PERFECT BOILER FOR EVERY NEED

Versatility 96 % ::::::::::::::::::::::::::::::::::::::: the best. mod/con Performance. and UP TO. DOE AFUE Efficiency.

Bosch Buderus SSB800/1000/1000TL Stainless Steel Condensing Boiler

Cooling Capacity CFM in. w.c. (125 Pa)

Product Data BW9 WATER BOILER SERIES B

Bosch Buderus SSB1000TL/TL2/TL3/TL4 Stainless Steel Condensing Boiler

Wt. Lbs Model Number (BTUH) Hz

AFUE up to 85.2% Heating Input 105,000 to 245,000 Btuh

Tankless Water Heaters

WHY TANKLESS? HOW TANKLESS WORKS LONGER LASTING CONTINUOUS HOT WATER CLEAN & FRESH WATER ENERGY SAVINGS SPACE SAVINGS. Secondary Heat Exchanger

Residential/Commercial Gas Tankless Water Heaters TANKLESS HIGH EFFICIENCY CONDENSING MODELS FEATURES INDOOR MODELS ATI-240H, ATI-340H, ATI-540H

Mascot. Gas-Fired Residential and Commercial Wall-Mounted Boiler. Easy Installation, 96% Efficiency, Fully Condensing

Engineer: Project Name: Project Location: Contractor:

RG7D 1-Stage Heat Series

Cooling Capacity CFM in. w.c. (125 Pa)

Automatic Circulating Water Heaters

Engineer: Project Name: Project Location: Contractor:

MASCOT II. Gas-Fired Wall-Mounted Combination Boiler & Water Heater

M3RL Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. High Efficiency / Direct Vent Condensing Downflow Gas Furnace

For More Information Click Here or Call General Supply M7RL Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS

SERIES 24. Series 24 Features. Commercial, Forced Draft, Hot Water or Steam Boiler. The right fit for any commercial job

95% SERIES 2 HEAT ONLY AND COMBINATION GAS WALL MOUNT BOILERS. Bringing. heat and hot water into perfect Balance

Trinity Lx200 High Efficiency Gas Condensing Boiler & Water Heater

SENSEI Series Features

THE ALL NEW COMBI BOILER

Cooling Capacity CFM range

TABLE OF CONTENTS BRADFORD WHITE BOILERS

TSTAT0201CW Recommended (sold separately)

Commercial Gas Water Heaters

Trinity Tft High Efficiency Gas Condensing Boiler & Water Heater

G6RC Series TECHNICAL SPECIFICATIONS

Commercial Gas Water Heaters

Description Model Weil-McLain part number. Vent Termination Kit for 3" Stainless Steel All

MECHANICAL VENTING VERSATILITY

Transcription:

The Leader in Condensing Technology NHB High Efficiency Condensing Boilers Navien innovation. Now available in a space saving wall hung boiler. New NaviLink Wi-Fi remote control system... Now available as an add-on accessory.

Navien NHB condensing boilers As the leader in condensing 2018 technology, Navien has already reinvented the water heating industry with the award-winning NPE tankless water heaters and the NCB combi boilers. The new NHB boiler series is the next in line of innovations from Navien. All NHB boilers have Navien s advanced burner system, an industry-leading AFUE of 95.0% and turn down ratios up to 15:1. The NHB boiler is now available is four sizes: 55 MBH, 80 MBH, 110 MBH and 150 MBH. Space saving Easy to install The sleek wall hung design uses much less space than traditional floor standing boilers. 1/2" gas connections and 2" PVC venting help reduce installation time. CASCADE 16 UP TO UNITS NHB CONTROL Industry s largest turn down ratio providing high operational efficiencies through multiple zones. Recognized as the most efficient in 2016 by Energy Star. 2" or 3" PVC, CPVC, approved polypropylene (see installation manual for more details). 2" or 3" special gas vent type BH (Class III, A, B, C). Gives the installer the ability to maximize boiler performance and temperature control. The cascading feature for 150 and 110 models will enable 1 16 units based on demand and balance workload for longer life. The smart integrated control provides industry leading options and features in the boiler operation parameters, including: Adjustable heat capacity A timed hydronic supply water boost feature Adjustable anti-cycle timer Freeze protection Pressure LWCO with manual reset Adjustable minimum burner time setting Adjustable turn down ratio timing Outdoor reset and domestic hot water priority Adjustable outdoor temperature reset curves Field gas convertible Total control All system setup, operations and troubleshooting available at your fingertips. Before After

NHB: the inside story Inlet air filter 2" PVC exhaust venting capable up to 60' Air vent connection Metal fiber premix burner Ignition transformer Mixing gas chamber Igniter and flame rod Dual Venturi for easy field convertibility Primary stainless steel heat exchanger Fan and motor Pressure sensor and LWCO Printed circuit board Secondary stainless steel heat exchanger NHB Control Gas valve Powder-coated enamel metal housing Condensate trap 1/2" gas pipe capable up to 40' Gas input ranges Warranty Model Range TDR NHB-55 8,000 55,000 BTU/H 7:1 NHB-80 8,000 80,000 BTU/H 10:1 NHB-110 10,000 110,000 BTU/H 11:1 NHB-150 10,000 150,000 BTU/H 15:1 Type Residential Commercial Heat Exchanger 15 years 10 years Parts 5 years 3 years Labor 1 year 1 year The Leader in Condensing Technology

Common venting up to 8 units and cascade capable up to 16 units Navien s two largest condensing boilers, NHB-110 and NHB-150, can be cascaded and common vented With our cascading technology, when a unit gets up to 70% capacity determined by the supply and return temperatures, the next unit will enable to help meet the hydronic space heating requirements. This hydronic space heating requirement and demand ratio will continue until all units are generating the needed hydronic space heat up to the maximum cascaded capacity. The Navien cascading system also balances out the workload of each unit for longer life. The NHB is dual certified for single and 2-pipe venting applications. Manifold Kits Navien s Manifold kits are ideal for hydronic space heating applications. With these manifolds, we have done the piping work for you. Both primary and secondary loop manifold kits are designed to work on all NHB models for fast and clean installations. All you need to add is your own appropriately sized pump. NHB Primary Manifold Kit GFFM-MSOZUS-001 NHB Secondary Manifold Kit GFFM-SKTZUS-001

Accessories NaviLink Wi Fi Control This add-on accessory will enable customers with smartphones and tablets to control temperatures remotely, access usage data and receive diagnostic notifications on all Navien products (NPE-A, NPE-S, NCB-E, NHB). PBCM-AS-001 SmartZone+ Pump Controller Zone pump controller designed to work with NHB series units allowing control from 2 to 6 zone pumps. 2 Zones: PFMZ-02P-001 3 Zones: PFMZ-03P-001 4 Zones: PFMZ-04P-001 6 Zones: PFMZ-06P-001 System Supply & Return Sensors Designed to sense supply and return temperature of your hydronic heating system. Works with all NHB series boilers. (Sold in pairs.) GXXX001417 Common Vent Collar kit Required for cascade/ common vent installations with NHB series units produced on or after September 15, 2016. Includes cascade cable. 30014367A Cascade Cable GXXX000546 Ready-Link Rack Base The free standing rack system is designed for infield assembly and indoor installation only. Base rack allows installation for up to 2 units back to back. GFFM-KDIZUS-001 Ready-Link Rack Add-on Designed to expand the base rack system allowing up to 16 units back to back. GFFM-KDIZUS-002 Commercial Neutralizer Designed to neutralize the condensate of up to 16 NHB series units. GXXX001325 Light Commercial Neutralizer Designed to neutralize the condensate of up to 6 NHB series units. GXXX001324 Replacement Media Commercial: GXXX001329 Light Comm: GXXX001328 Residential Neutralizer Kit, Single Unit Residential condensate neutralizer for NHB series units designed to neutralize the condensate of one unit. GXXX001322 Replacement Media for Residential Neutralizer GXXX001323 Plumb Easy Valve Set, 1" 1" isolation valves without relief valve designed to work on NHB series units. Allows for easy and quick servicing of hydronic space heating systems. 30010950A The Leader in Condensing Technology

Dimensions Overhead View A B 15.9 (405 mm) 6.6 (170 mm) 4.5 (115 mm) 3 (77 mm) 2.6 (67 mm) C 2.3 (60 mm) Ratings & specifications Model Number 1 Navien Condensing Boiler Space Heating Ratings Heating Input, MBH Min Max Heating Capacity 2, MBH Net AHRI Rating, Water 3, MBH AFUE 2, % NHB-55 8 55 51 44 95.0 NHB-80 8 80 74 64 95.0 NHB-110 10 110 102 89 95.0 A B C 17.3 (440 mm) Connection Size Air Intake Φ 2 Exhaust Gas Vent Φ 2 Air Vent Connection Φ 3/4 Front View NHB-150 10 150 138 120 95.0 1 Ratings are the same for Natural Gas models converted to Propane use. 2 Based on U.S. Department of Energy (DOE) test procedures. 3 The NET AHRI Water Ratings shown are based on a piping and pickup allowance of 1.15. Consult Navien before selecting a boiler for installations having unusual piping and pickup requirements, such as intermittent system operation, extensive piping systems, etc. Specifications Item NHB-55 NHB-80 NHB-110 NHB-150 Dimensions 24" (H) x 17" (W) x 12" (D) 24" (H) x 17" (W) x 13" (D) Weight 73 lbs (33 kg) 80 lbs (36 kg) 23.6" (600mm) Installation type Venting type Indoor wall-hung Forced draft direct vent Ignition Natural gas supply pressure (from source) Electronic ignition 3.5" 10.5" WC Supply Connections D E F G H I Propane gas supply pressure (from source) 8.0" 13.5" WC Natural gas manifold pressure -0.03" WC -0.08" WC -0.10" WC -0.40" WC Propane gas manifold pressure -0.03" WC -0.07" WC -0.09" WC -0.30" WC Gas connection size 3/4" NPT (female) 13.1 (335 mm)* 15.8 (401 mm) 6 (152 mm) * NHB-055/080: 11.8 (300 mm) 2.3 (60 mm) 5.5 (141 mm) Power supply Materials Main supply Maximum power consumption Casing Heat exchangers 120V AC, 60Hz Less than 10A Cold rolled carbon steel Primary and secondary heat exchangers: stainless steel Connection Size D Rubber Grommet Φ 1 E Space Heating Return Φ 1 F Condensate Outlet Φ 1/2" G Knock Out Hole Φ 3/4 H Gas Connection Φ 3/4 I Space Heating Supply Φ 1 Venting Exhaust Intake Vent clearances 2" or 3" PVC, CPVC, approved polypropylene (see installation manual for more details) 2" or 3" special gas vent type BH (Class III, A/B/C) 2" or 3" PVC, CPVC, polypropylene 2" or 3" special gas vent type BH (Class III, A/B/C) 0" to combustibles Safety devices Flame rod, APS, gas valve operation detector, ignition operation detector, water temperature high limit switch, exhaust temperature high limit sensor Navien Inc. 20 Goodyear, Irvine, CA 92618 800-519-8794, Navien.com NHB-BR002-1711 2017 Navien Inc. The Leader in Condensing Technology