LTFX Electric Tank Immersion Heaters Installation Instructions

Similar documents
INSTALLATION, OPERATING & MAINTENANCE INSTRUCTIONS FOR 350 SERIES CIRCULATION HEATERS

Circulation Heaters Selection Guidelines

Circulation Heaters Selection Guidelines

Installation and Operation Instructions. Versa. Screw Plug Oil & Water Immersion Heater. PD January 2018

Chromalox. Installation, Operation. Circulation Heaters for Oil or Water Heating RENEWAL PARTS IDENTIFICATION PE GENERAL NWH

RENEWAL PARTS IDENTIFICATION. Type TTUH and TTUH-CO URN Heaters. Dimensions (In.) Extends. Model Volts kw W/In 2 A B C D

INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS FOR PIPE THREAD IMMERSION HEATERS USED IN HAZARDOUS LOCATIONS

HD3D Forced-Air Heater

Installation Instructions U-RAD-LT Electric Radiant Heaters

WATLOW IND. WATROD Circulation Heater Installation & Maintenance Manual I&M NUMBER: Page: 1 Date: 6/11/2008 Rev: 2.00

WATLOW IND. WATROD Flange Heater Installation & Maintenance Manual I&M NUMBER: Page: 1 Date:6/11/2008 Rev: 2.00

WATLOW IND. FIREBAR Flange Heater Installation & Maintenance Manual I&M NUMBER: Page: 1 Date: 6/11/2008 Rev: 2.00

Type STAR Radiant Heater For Portable Installations

! The Caution Symbol (exclamation point) alerts you to a "CAUTION", a safety or

INSTALLATION, OPERATING & MAINTENANCE INSTRUCTIONS FOR 870 SERIES INDUSTRIAL CONTROL PANELS

PILOT VALVE ENCLOSURES FOR HAZARDOUS LOCATIONS PENTAIR CLEAN AIR SYSTEMS

Installation Instructions Type XPMC Air Heater for Hazardous Locations

WATLOW ELECTRIC MFG CO. FIREBAR Screw Plug Installation & Maintenance Manual I&M NUMBER: Page: 1 Date: 11/25/2013 Rev: 4.

WATLOW IND. WATROD Modular Duct Heater Installation & Maintenance Manual I&M NUMBER: Page: 1 Date:6/11/2008 Rev: 2

Chromalox. Installation, Operation. Portable Industrial Unit Blower Air Heater Types SDRA and SDRA-RG RENEWAL PARTS IDENTIFICATION

PILOT VALVE ENCLOSURES FOR HAZARDOUS LOCATIONS

USER INSTRUCTIONS FOR FLANGE IMMERSION HEATERS USED IN HAZARDOUS LOCATIONS

standards: standards:

Intrinsically Safe Pressure Transmitters for installation in hazardous locations Models IS-20-S, IS-21-S, IS-20-F, IS-21-F WIKA Datasheet IS-20

Differences Among Screw Plug Immersion Heaters

Pipe Thread Heaters. Construction Features. Star Electric to Order Call " 2-1/2" Pipe Thread Heaters

CFP4, 8 or 12 Exde Immersion Heater. CERTIFIED TO IEC :2000, IEC :2001 and IEC :2001

WATLOW ELECTRIC MANUFACTURING COMPANY

Immersion heaters for ATEX/IECEx hazardous areas or in non-atex version

Chromalox. Installation, Operation. Screw Plug Heating Solution Control Panel Assembly for Screw Plug Heaters RENEWAL PARTS IDENTIFICATION

Duct heaters for ATEX/IECEx hazardous areas or in non-atex version

Circulation Heaters. To order, call or shop online at omega.com SM. CHF Series

Description. Applications

CNA-Series - Large Industrial Heaters Tankless Water Heating Solutions

Portable CNA-Series - Large Industrial Heaters Tankless Water Heating Solutions

Circulation Heaters. To order, call or shop online at omega.com SM. CHF Series

Circulation Heaters. To order, call or shop online at omega.com SM. CHF Series

Circulation Heaters. To order, call or shop online at omega.com SM. CHF Series

Circulation Heaters. To order, call or shop online at omega.com SM. CHF Series

Circulation Heaters. To order, call or shop online at omega.com SM. CHF Series

REGULATIONS EUROPEAN ATEX DIRECTIVE. INTERNATIONAL SCHEME: IECEx AREAS CLASSIFICATION DEFINED BY DIRECTIVE 1999/92/EC

INSTRUCTION MANUAL. D2xB1XH1 & D2xB1XH2 Xenon Beacons For use in Hazardous Locations

INSTRUCTION MANUAL. E2xB05 & E2xB10 Xenon Beacons For use in Hazardous Locations

Explosion-proof Immersion Heater Type D-8660

Installation, Operation and. Maintenance Instructions

EJBX. Ex d. AISI 316L stainless steel. - Zone 1, 2, 21, 22 - Group IIB+H2 - Stainless steel junction boxes - Choice of 13 sizes - IP 66 / 67

Keltech SNA-Series - Safety Shower Heaters Tankless Water Heating Solutions

WATLOW ELECTRIC MANUFACTURING COMPANY

WATLOW ELECTRIC MFG CO. WATROD Duct Heater (module only) I& M Manual I&M NUMBER: Page: 1 Date: 11/25/2013 Rev: 4.00

Circulation heaters for ATEX/IECEx hazardous areas or in non-atex version

INSTALLATION OPERATION AND MAINTENANCE INSTRUCTIONS FAW, FAW-C & FAW-C-T TYPE AIR WARMERS FCR & FCR-A TYPE CONVECTORS

CXH-A Forced-Air Heater

G Series SAVE THESE INSTRUCTIONS. (Model B) Convector Heater for Hazardous Locations GENERAL! INSTALLATION

Screw Plug Immersion Heaters

INSTRUCTION MANUAL (ATEX / IECEx)

C D E F. Tubular Industrial Process Circulation Heaters. Circulation Heaters. View Product

INSTALLATION & OPERATING INSTRUCTIONS

INSTALLATION OPERATION AND MAINTENANCE INSTRUCTIONS EXHEAT FLR TYPE FLAMEPROOF RADIATORS

Portable C2N Series - Light Industrial Heaters Tankless Water Heating Solutions

SNA-SKID Series - Preassembled Safety Shower Heater Skid Tankless Water Heating Solutions

Circulating Oil Temperature Control System

Flanged Immersion Heaters

S19361F - Pre-Assembled Freeze-Protected Safety Shower Heater Skid Tankless Water Heating Safety Solutions

Explosion Protected Panelboards D2Z Series

Flanged Immersion Heaters

Technical Specification VFD

INSTRUCTION & SERVICE MANUAL

Flanged Immersion Heaters

Portable C1N Series - Light Industrial Heaters Tankless Water Heating Solutions

3-6VFD Series Combination Flame and Explosion Proof Pilot Valve Enclosure

Installation, Operation, Maintenance Instructions and RENEWAL PARTS IDENTIFICATION

Cartridge Heaters. Components. Application Guidelines

SERIES 46000E Bi-Directional In-Line Deflagration Flame Arrester

Checklist Selecting the Proper Flanged Heater

Discontinued. SN Series - Safety Shower Heaters Tankless Water Heating Solutions. Standard Equipment. Construction. Code Compliance and Certifications

INSTRUCTION MANUAL. D1xB2XH2 Xenon Beacon For use in Hazardous Locations. 2) Rating & Marking Information

INSTRUCTION MANUAL. D1xB2XH1 Xenon Beacon For use in Hazardous Locations. 2) Rating & Marking Information

C1N Series - Light Industrial Heaters Tankless Water Heating Solutions

WARNING WARNING. Installation Instructions for 116DEXSTC-FJ AdaptaBeacon Fire Alarm Strobe Lights for Use in Hazardous Locations.

Officine Meccaniche M.A.M. series for command, control, signaling and/or automation. DOCUMENT IS-EJB-A-14 rev. 0

Certification Supplement Manual

How 1 is your resistance. wire sized? What grade of magnesium oxide is being used? How 3 is your cold pin attached to your resistance wire?

AEU1. Explosion-Proof Electric Air Heater For Hazardous Locations

Immersion Heaters. Screw Plug Immersion Heater

INSTALLATION OPERATION AND MAINTENANCE INSTRUCTIONS EXHEAT INDUSTRIAL FLR & FLRA TYPE FLAMEPROOF RADIATORS

Thermal Devices Inc. Mount Airy, Maryland USA Process Air and Radiant. ADH Typical Installation.

INSTRUCTION MANUAL (ATEX / IECEx)

Overview of Hazardous Locations as They Relate to Solenoid Valves

CLE SERIES Fluid heating for emergency eyewash stations

TECHNICAL DATA. Wet 26a. February 22, 2009

Installation, Operation and

Installation and Operating Instructions ISH ELECTRIC STEAM SUPERHEATER

569, 570, 571, 572 Series

C1N & C2N SERIES Fluid heating for light industrial applications

Model ESFR-17 Dry Type Pendent Sprinklers Early Suppression Fast Response 16.8 K-factor General Description

UL Topic III. Converting European EEx Certificates. Into. North American Division Certificates

Patterson/AMT Inline Circulator Pump Refer to pump manual for General Operating and Safety Instructions.

Tubular Industrial Process

Explosion Resistant Unit Heater Owner s Manual This manual covers installation, maintenance, repair, and replacement parts.

Operating Instructions

Transcription:

LTFX Electric Tank Immersion Heaters Installation Instructions 1 PN403-5 161-049178-101 March 2017

LTFX Electric Tank Immersion Heater Installation Instructions General The Chromalox Electric Tank Immersion Heater, Model LTFX, is an engineered, pretested package designed to give years of virtually maintenance free service and it is shipped ready for installation into a storage tank. LTFX provides low watt-density heating over a large heating surface with precise temperature control for such materials as asphalt, fuel oil, pitch and tar, liquid sugar, lube oils, linseed oil, biodiesel, glycerin, ethanol and many other heat sensitive compounds. The open coil heating elements (OCE) are housed in either 2 or 3 Schedule 40 carbon or stainless steel pipes, which are welded into the 150# ANSI flange. Once the Unitary Immersion Heater is mated to your tank, the heating elements may be removed and replaced without draining the tank. Since excessive temperatures may permanently damage the heater and cause premature failure, the use of temperature controls, limiting controls, and liquid level sensors are required. The system designer is responsible for the safety of this equipment and should install adequate back-up controls and safety devices with their electric heating equipment. Where the consequences of failure could result in personal injury or property damage, back-up controls are essential. Installation FIRE OR EXPLOSION HAZARD: The tank must be purged of all flammable vapors prior to cutting or welding. High heating efficiency, low element temperatures, and longer heater life are achieved when the unit is properly installed. 1. To avoid chipping or cracking, precaution should be taken while unpacking, handling, and installing the ceramic insulators. Heaters with damaged insulators should be returned to the factory for repair or replacement. Contact your local sales office for return authorization. 2. The LTFX unit must not be mounted in the vertical position as the resistance wire on the OCE element can sag, thus causing uneven heating or short circuit. Unit should be installed in a horizontal position with the thermowell on top only. FIRE OR EXPLOSION HAZARD: Mount the heater in a level, horizontal orientation only. All other orientations may result in property damage or personal injury. 3. IMPORTANT: Mount heater in the tank so the liquid level will always be above the effective heated portion of the heater. Provide expansion tank if necessary. 4. Select a location for this installation according to the following guidelines: (refer to Figure 1) A. Heating elements are removable through the terminal enclosure however adequate room must be provided for this purpose. The removal length of the OCE heating element is 3 feet since the center section may be bent on a 12 radius. OCE elements should only be bent in a vertical plane with ground strap on the bottom. B. The neck on the tank s mating flange should be of adequate length to accommodate tank insulation and flange bolting. 5. Tube supports (internal to the tank) should be placed approximately three feet from the wet-side of the LTFX flange to ensure gasket sealing integrity. Additional tube supports can then be spaced on 10 foot centers. Do not anchor the heater tubes to the supports, as the tubes must be allowed to expand. 6. To ensure proper sealing, a material appropriate gasket needs to be installed between the mating flanges. The mating flanges should then be secured by tightening the bolting according to TEMA Standards. 7. A tank suction pipe should be mounted at least 2 above the level of the heaters. A separate line can be provided to drain tank after heaters have been de-energized. 2

Allow for Tank Insulation and Bolting 36 Min. Element Removal Distance Fluid Level Open-Coil Elements Model LTFX Figure 1 Wiring ELECTRIC SHOCK HAZARD. Disconnect all power before installing or servicing heater. Failure to do so could result in personal injury or property damage. Heater must be installed or serviced by a qualified person in accordance with applicable National Electric Codes, NFPA 70 and/or International Electric codes. ELECTRIC SHOCK HAZARD. Any installation involving electric heaters must be performed by a qualified person and must be effectively grounded in accordance with applicable National Electric Codes and/or International Electric Codes to eliminate shock hazard. The system designer is responsible for the safety of this equipment and should install adequate back-up controls and safety devices with their electric heating equipment. Where the consequences of failure could result in personal injury or property damage, back-up controls are essential. 1. Electrical wiring to heating elements must be sized and installed in accordance with applicable National Electric Codes, International Electric Codes and/or and applicable local codes by a qualified person as defined by the code. 2. Temperatures at the heater terminals will require the use of manganese nickel or equivalent temperature lead wire. (Type TGS, TGT, or TGGT are recommended.) Wiring Entrance Locations - Moisture Resistant Housing Only (E4 Option) The Moisture Resistant (E4) Housing offers several convenient options for conduit wiring & location. The housing is equipped with two removable service entrance plates for installation of wiring. Any or all of the six sides can be used for wiring locations. Refer to exploded view drawing. The housing can also be rotated (by removal from flange) to allow for more position possibilities. To install service entrance holes, simply remove the side Allen screws and use the centering depression to drill the appropriate size hole. Reinstall the gasket(s), if applicable, and service entrance plates by tightening the Allen head screws to 4-5 in/lbs. The Octobox style of housing can be removed for ease of access to element bussing or to better locate the power conduit(s) entry point. To accomplish, simply remove the Allen-head screws on the outside of the housing. 3

When reinstalling, be sure to properly align gasket, if applicable, and tighten to 40-50 in/lbs. Tip for Reinstalling Gaskets: Place allen head screws through metal covers and gentle push gasket hole over the threaded screw. This will allow the gasket to stay in place while tightening the cover. Table A E4 Wiring Information Heater kw Volts Phase Total Amps Circuits LTFX-125-004E4 4 480 3 4.8 1 LTFX-128-008E4 8 480 3 9.6 1 LTFX-1212-012E4 12 480 3 14.5 1 LTFX-2212-024E4 24 480 3 28.9 1 LTFX-3212-036E4 36 480 3 43.4 1 LTFX-2325-060E4 60 480 3 72.3 1 LTFX-3325-090E4 90 480 3 108.4 3 LTFX-4325-120E4 120 480 3 144.5 2 LTFX-6325-180E4 180 480 3 216.8 3 LTFX-8325-240E4 240 480 3 289.0 4 Wiring Entrance Locations - Explosion Resistant Housing Only (E2 Option) The Explosion Resistant (E2) Housing features dedicated conduit connection sizes and locations for either NPT installation of conduit or Metric cable glands. Incoming wiring must be suitable for a maximum terminal enclosure temperature of 158 F (70 C). Wiring installation must be in accordance with Hazardous Area requirements. The use of EYS seals or rigid conduit may be required. Please consult with the local inspection authority. Maximum Temperatures Safe operation in a hazardous location requires the maximum operating temperatures of all exposed surfaces of the heater including temperatures on the outside of the vessel, piping, flanges, screw plugs, enclosures and other heat conducting parts be limited. The flammable liquids, vapors or gases present determine the maximum surface temperature permitted in any hazardous location. The end user or purchaser of the electric heating equipment is responsible for determining the proper classification of an area and for providing Chromalox with hazardous area specifications and requirements for proper equipment design. (NEC and IEC provide guidelines for evaluating and classifying hazardous locations.) An approved liquid level control or overtemperature control must be installed to deenergize the heater if the liquid level drops below the top of the heater. Maximum fluid temperature per following table: Temperature Class Maximum Fluid Temperature T1 (450 C) 440 C T2 (300 C) 290 C T3 (200 C) 195 C T4 (135 C) 130 C T5 (100 C) 95 C T6 (85 C) 80 C The external surfaces of the heater must not exceed the marked fluid temperature. An over-temperature control should be used if there is a possibility of the heater s external surface temperature exceeding the fluid temperature. 4

Table B E2 Wiring Information Heater kw Volts Phase Total Amps Circuits LTFX-125-004E2 4 480 3 4.8 1 LTFX-128-008E2 8 480 3 9.6 1 LTFX-1212-012E2 12 480 3 14.5 1 LTFX-3210-024E2 24 480 3 28.9 1 LTFX-3215-036E2 36 480 3 43.4 1 LTFX-3225-060E2 60 480 3 72.3 1 LTFX-4225-090E2 90 480 3 108.4 2 LTFX-8215-120E2 120 480 3 144.5 2 LTFX-9220-180E2 180 480 3 216.8 3 LTFX-12225-240E2 240 480 3 289.0 4 Explosion Resistant Housing Conduit Entry Table Standard Construction Optional Construction Flange Size (In.) Conduit/Cable Entries Per Enclosure Conduit/Cable Entries Per Enclosure 3/4 NPT 1-1/2 NPT M20 M40 4 & 5 1 1 1 1 6 1 1 1 1 8 1 2 1 2 10 1 2 1 2 12 1 2 1 2 14 1 3 1 3 16 1 3 1 3 18 1 4 1 4 Note: A minimum of 5 full threads must be engaged on all cable and conduit entries. Third Party Certifications E4 Moisture Resistant Enclosure Certifications North American Designations(s) Canadian European International Rating NEMA 4 NEMA 4 IP66 IP66 Agency(s) Manufacturers Declaration Manufacturers Declaration E2 Explosion Resistant Enclosure Certifications Rating North American Designations(s) Explosion Resistant Canadian Explosion Resistant European Explosion Resistant International Explosion Resistant Agency(s) CSAus CSA ATEX IECEx Ratings Class I, Div. 1 Groups B, C & D Class II, Div. 1 Groups E, F & G Class I Zone 1 AEx d IIB + H2 Gb T1 to T6 Class I, Div. 1 Groups B, C & D Class II, Div. 1 Groups E, F & G Class I Zone 1 Ex d IIB + H2 Gb T1 to T6-50 C < Ta < +60 C 0359 II 2 G Ex d IIB+H2 Gb T1 to T6 IP66 Ex d IIB+H2 Gb T1 to T6 IP66 *Note: Temps over T3 (200 C) require stand-offs for third-party listing. Refer to IECEx and ATEX certificates for stand-off dimensions. 5

Operation FIRE OR EXPLOSION HAZARD. To avoid possible damage to the heater, do not energize until the tank is filled with fluid. Recommended fluid level is 2 above the heater tube or pipe. FIRE or EXPLOSION HAZARD. Do not open enclosure when energized. Do not open enclosure when an explosive gas atmosphere is present. 1. Do not operate heaters at voltages in excess of that stamped on the heater, since excess voltage will shorten heater life. 2. Heaters should not be operated in environments with factors that can destroy the electrical insulating characteristics of the ceramic insulators. Foreign contaminants can create leakage (shock) hazards, permanent heater damage, or cause heater failure and therefore should be avoided. For initial operation and tuning the control scheme: 1. Turn the master circuit breaker off and open the control box door. 2. Set the indicating temperature control at the desired temperature and the over-temperature cutout at 50 F above this temperature. 3. Interlock the liquid level control with the cutout device. 4. Close the control box door and turn the circuit breaker on. To energize the heater circuits, turn the on-off selector switch to the on position. Maintenance FIRE or EXPLOSION HAZARD. Do not open enclosure when energized. Do not open enclosure when an explosive gas atmosphere is present. ELECTRIC SHOCK HAZARD. Disconnect all power before installing or servicing heater. Failure to do so could result in personal injury or property damage. Heater must be installed or serviced by a qualified person in accordance with applicable National Electric Codes, NFPA 70, and/or International Electric Codes. 1. Make certain both the terminals and the ceramic insulators are free from contact with oil, liquid, or other foreign matter. NOTE: Chromalox cannot be responsible for failures or damage caused by contamination on the ceramic insulators. Make certain the heaters are not exposed to contaminants. 2. Check electrical connections at heater terminals and tighten if necessary. This will help avoid hot terminals which may destroy wire insulation or heater terminals 3. Check overheat operation to assure heater protection. Element Replacement - Moisture Resistant Housing Only (E4 Option) 1. To remove the OCE heating elements, first turn the circuit breaker to the off position. 2. Next remove the housing lid, element wiring and the element mounting screw. Now pull the element straight out of the heating tube. NOTE: OCE elements should only be bent in a vertical plane with ground strap on the bottom. 3. When removing the heating elements, make certain that the terminals and the ceramic insulators do not contact oil or any other liquid foreign matter. Note: Chromalox cannot be responsible for failures or damage caused by contamination on the ceramic insulators. 4. Installation is the reverse of the above. Element Replacement - Hazardous Locations, Explosion Resistant Housing Only (E2 option) 1. To remove the OCE heating assembly, first turn the circuit breaker to the off position. 2. Next remove the housing lid, element wiring, and 8mm bolting around the element flamepath module. If bolts must be replaced, use a minimum of grade 10.9. If needed, (2) M6-1.0 bolts may be used to break loose the module from the flange. Turn bolts evenly until module is free. The flamepath module will be re-used, so disconnect the heating element from the module pins. Now pull the element assembly out of the heating tube. NOTE: OCE elements should only be bent in a vertical plane with ground strap on the bottom. 3. When removing the heating elements, make certain that the terminals and the ceramic insulators do not contact oil or any other liquid foreign matter. Note: Chromalox cannot be responsible for failures or damage caused by contamination on the ceramic insulators. 6

4. Inspect the element assembly flange and mating surface for any debris, oils, or contamination. NOTE: Surfaces must be in suitable condition to ensure proper hazardous rating. 5. Wire connection to OCE heating element should be made using ring connectors. Wire connection to flamepath module must be made with crimp-style barrel connectors. If wires between flamepath module and OCE element need to be replaced, the wires should be rated for a minimum of 250 C. It is also required to cover the barrel connector, wire and ring connector with electrical sleeving to prevent unwanted grounding. Connect the new element to the flame path module by wiring connection(s) to the OCE element and slide the OCE element into tube. 6. Connect the new element to the flamepath module and slide into tube. Flamepath module bolting must be tightened to 26 ft/lbs. of torque. 7. Reattach element wiring. When reinstalling housing lid, be sure to properly align gasket, and tighten housing bolts to 26 ft/lbs. Renewal Parts Identification Table C E4 Housing Renewal Parts Identification Heater Model kw Volts Phase Immersion Length In. (mm) ANSI Flange Size Number of Tubes Nominal Tube Dia. (In) Replacement OCE Model No. LTFX-125-004E4 4 480 3 60 (1,524) 4" - 150# 1 2 OCE-05040-2-483 LTFX-128-008E4 8 480 3 96 (2,438) 4" - 150# 1 2 OCE-06080-2-483 LTFX-1212-012E4 12 480 3 144 (3,658) 4" - 150# 1 2 OCE-12120-2-483 LTFX-2212-024E4 24 480 3 144 (3,658) 6" - 150# 2 2 OCE-12120-2-483 LTFX-3212-036E4 36 480 3 144 (3,658) 6" - 150# 3 2 OCE-12120-2-483 LTFX-2325-060E4 60 480 3 300 (7,620) 8" - 150# 2 3 OCE-25300-3-483 LTFX-3325-090E4 90 480 3 300 (7,620) 10" - 150# 3 3 OCE-25300-3-483 LTFX-4325-120E4 120 480 3 300 (7,620) 10" - 150# 4 3 OCE-25300-3-483 LTFX-6325-180E4 180 480 3 300 (7,620) 12" - 150# 6 3 OCE-25300-3-483 LTFX-8325-240E4 240 480 3 300 (7,620) 14" - 150# 8 3 OCE-25300-3-483 Table D E2 Housing Renewal Parts Identification Heater Model kw Volts Phase Immersion Length In. (mm) ANSI Flange Size Number of Tubes Nominal Tube Dia. (In) Replacement OCE Model No. LTFX-125-004E2 4 480 3 66 (1,676) 4" - 150# 1 2 OCE-06040-2-483 LTFX-128-008E2 8 480 3 96 (2,438) 4" - 150# 1 2 OCE-06080-2-483 LTFX-1212-012E2 12 480 3 144 (3,658) 4" - 150# 1 2 OCE-06080-2-483 LTFX-3210-024E2 24 480 3 120 (3,048) 8" - 150# 3 2 OCE-06080-2-483 LTFX-3215-036E2 36 480 3 180 (4,572) 8" - 150# 3 2 OCE-06080-2-483 LTFX-3225-060E2 60 480 3 300 (7,620) 8" - 150# 3 2 OCE-25200-2-4803 LTFX-4225-090E2 90 480 3 300 (7,620) 10" - 150# 4 2 OCE-25225-2-4803 LTFX-8215-120E2 120 480 3 180 (4,572) 12" - 150# 8 2 OCE-15150-2-4803 LTFX-9220-180E2 180 480 3 240 (6,096) 14" - 150# 9 2 OCE-25200-2-4803 LTFX-12225-240E2 240 480 3 300 (7,620) 14" - 150# 12 2 OCE-25200-2-4803 7

Limited Warranty: Please refer to the Chromalox limited warranty applicable to this product at http://www.chromalox.com/customer-service/policies/termsofsale.aspx. Chromalox, Inc. 1347 Heil Quaker Boulevard Lavergne, TN 37086 (615) 793-3900 www.chromalox.com 8 2017 Chromalox, Inc.