Welding Job Knowledge

Similar documents
& FOREHEARTHS INNOVATION ENGINEERED IN GERMANY

Data Sheet. Self regulating process heating tapes RS stock numbers ,

Data Sheet. Self regulating heating tapes. RS stock numbers

4. A 2 X4 knee wall, if insulated, should be to what R value? 5. The clearance between insulation and a furnace vent should be:

Metal Turbine Exhaust Joints An analysis of metal and fabric GTX expansion joints

Understanding of Surface Heat Tracing of Bulk Storage Tanks for Viscous and High Pour Point Fluids - By, H. R. Mullan

SECTION DUCTWORK

A Newsletter published by ESI. The Steam and Power SPECIAL FORCES

Conductive Heating Technologies for Medical Diagnostic Equipment. Russell Strehlow, Manager of Research and Development, Minco

Thermal Fluid Heaters

Socket Heat Fusion Techniques. A Guide for Instruction and Training in Vanguard Socket Heat Fusion

CERTIFICATE OF FIRE APPROVAL

Efficient Steam System Design

Press Release. How can the efficiency of the dryer section be increased? Dryer Section All Paper Grades. Heimbach wherever paper is made.

FireMaster Instrument cable tray fire protection

Originators of the Flexible Water Tube design

Originators of the Flexible Water Tube design

HEATING INVERTER DHC 6510R WELD PREHEATING AND STRESS RELIEVING

S&T HEAT EXCHANGERS Part II: Main Parts, Conical Transitions, Shell & Heads, Nozzle Design.

Bimetal Disc Thermostat. Product Information and Application Notes

Ceramic Fiber Heaters

CI/SfB X. RHeco Series CONDENSING GAS FIRED UNIT HEATERS

Enclosure Temperature Control

This Chapter Sponsored by CASTOOL Tooling Solutions

USER S INFORMATION MANUAL

Snifter ATEX22 VERSION. User Manual. Distributor

TC MODULE (FFD) (with Gas Hob)

There are two devices used together for heating crude oil in petroleum refinery as in figure (1), and these devices are:

Miniature Hobby Boiler Inspection and Certification Requirements

2. HEAT EXCHANGERS MESA

FIBERSHIELD EW NEW PRODUCT LOW RADIANT HEAT TRANSFER ( PARTIAL PARTIAL INSULATION ) FIRE CURTAINS. Supported by full scale fire test data

A B C D E F G H I J K L M N O P Q R S T U V W X Y Z

SECTION HEATING BOILERS

Fiber-Insulated Heater Type RDI

Modifications and Improvements to the NPDGamma Liquid Hydrogen Target System and Safety

CRU-S Series Stainless Steel Condensate Recovery Unit

... RHeco. High Efficiency Condensing Unit Heaters... Low NO x. ErP. ErP Lot 21 Seasonal Efficiency and NOx compliant

... RHeco. High Efficiency Condensing Unit Heaters... Low NO x. ErP. ErP Lot 21 Seasonal Efficiency and NOx compliant

Installation Instructions

ELECTRIC UNDERFLOOR HEATING SYSTEMS. Operating Guide & Guarantee. The Underfloor Heating Specialists Tel:

Cold Weather Operation Of Cooling Towers

BHEL Steam Generators Material Selection Overview by Veerendar Aluvala DM/BHEL/Trichy

Originators of the Flexible Water Tube design

NOx REDUCTION EXPERIENCE ON NATURAL GAS FIRED TURBO FURNACES

Surface Temperature Tests on an LST Fan Convector

Inverted Bucket Steam Traps

Enclosure Temperature Control

TEMPRA. Wall Mounted Fan Flue System boiler. Wall mounted fanned flue boiler INSTALLATION AND USE INSTRUCTIONS. Appr. nr. B A - CE 0063 AQ 2150

SolarWall Fan Units. Introduction. Features. By Conserval Engineering Inc.

INTERNATIONAL STANDARD

Direct Vent Training & Installation Instructions for Venting 40/50 gallon models Telescoping Vent Kit (standard)

PERFORMANCE EVALUATION AND RECURRING JAMMING PROBLEM ANALYSIS OF AIR PREHEATER IN COAL-FIRED POWER PLANTS

Instruction Manual. Oil Heaters. Model: OIL5, OIL7, OIL9 & OIL11T READ AND SAVE THESE INSTRUCTIONS

WARRES No Page 1 of 27. Fire Resistance Test Generally In Accordance With BS 476: Part 22: 1987, Clause 5, on an Insulated Fabric Barrier

Compression of Fins pipe and simple Heat pipe Using CFD

Suggested Specifications Prestige Excellence 110

THE MUCH WENLOCK. Installation Instructions for Freestanding Much Wenlock Stove with Boiler

Int 937. Soldering Station. Instruction Manual. Correct Disposal of this product

Analysis of Triangle Heating Technique using High Frequency Induction Heating in Forming Process of Steel Plate

A CASE STUDY ON BOILER TUBE FAILURE AT JPL

Draft Controls. When to use a Draft Control

Installation & Service Manual. Models ALF 20, 30, 40, 50, 60, 80

SECTION DUCTWORK. A. Section Painting: Weld priming, weather resistant, paint or coating.

DAWN Electronics, Inc.

systemate 2000 fully integrated thermal store

UC152 and US152. Key Features. Hotplate with Stirrer, UC152 US152. Technical Specification. Ordering Information

GAS-FIRED ('INFRA-RED') HEATER FOR USE ON THE JOINTS

Flue Dilution Fans. Specialists in Air Movement Technology. IMPROVED GBDF MK5 Now includes a Pressure Safety Switch and easier Electrical Connections

FURNACES & OVENS LEADING INNOVATORS IN THERMAL TECHNOLOGY TO THE OIL & GAS, CHEMICAL AND POWER INDUSTRIES ASSET INTEGRITY PARTNER

Computer Modelling and Simulation of a Smart Water Heater

Jacopa Tipping Bucket

cookq90.com All Q90 products carry a comprehensive UK two-year parts and labour warranty.

Guidelines for energy efficient heating, ventilation and air conditioning (HVAC) systems

Report on Development of a 5-tonne Capacity Solar Biomass Hybrid Dryer for Drying Maize

- Essay Control Functions and Benefits

Temperature Sensors & Compression Seal Fittings

Gas-fired water heaters, volume III, storage water heaters with input ratings above 75,000 Btu per hour, circulating and instantaneous

MINTRAC MEAT INDUSTRY ENVIRONMENT CONFERENCE WASTE HEAT RECOVERY FROM RENDERING PLANTS PRESENTED BY DEREK HENDERSON

CELT STAR C GAS-FIRED WATER HEATER. Category: I 2E+ Installation and Use Instructions. Contents : Description:

ADVANCE ELECTRIC THERMAL STORE

Experimental Assessment of the Thermal Performance of Storage Canisterm01d ing Fix ture Conj?gurations

Meeting the One-Cup Challenge

the Quick Cook Instruction Book - LIC400

Flo-Rite-Temp Instantaneous Steam/Water Heater

Peerless Boilers. Peerless Pinnacle. High Efficiency Stainless Steel Boilers

SUPERTHAL. Heating Modules for Customized Furnaces and Heaters

Energy saving and better heat control.

5.5.1 General CD/30 (Oil Condensing Boiler Installation Assessment Form) General Technician Stationary...

Boiler Draft Equipment

Seed Drying. 1. Surface moisture of the seed that initially removed by the drying air.

Trade of Plumbing. Module 2: Domestic Hot and Cold Water Service Unit 10: Hot Water Supply Phase 2

Important Considerations When Selecting a Fan for Forced Air Cooling. By: Jeff Smoot, CUI Inc

Station Four Guide thermal energy and Motion Energy

Analysis to speed up of the start-up of steam boiler OP-380

High tube metal temperatures

IGEM/G/5 Edition 2 Communication 1762 Gas in multi-occupancy buildings

PROCESS HEAT PROCESS HEAT.

PESIT-Bangalore South Campus

Heat loss: the Reason for Heating

Packaged Marine Design Thermal Fluid (Hot Oil) Heaters

Transcription:

Heat Treatment - Part 3 When it is not possible to place the entire component in a furnace for heat treatment (because of the size of the fabrication, circumferential welds in a pipework system or when installing equipment on site, for example), then a local PWHT may be the only option. Local PWHT needs careful planning to ensure that heating and cooling rates are controlled and that an even and correct temperature is achieved. Uneven and/or rapid heating can give rise to harmful temperature gradients producing thermally induced stresses that exceed the yield stress. This may result in the development of new residual stresses when the component is cooled. Local PWHT may be carried out using high velocity gas burners, infra red burners, induction heating and high or low resistance heating elements. Electrical equipment is more easily installed and controlled than heating using natural gas or propane, particularly on site. High voltage resistance heating is rarely used on site due to the need for the radiant heaters to be positioned a set distance from the surface and, more significantly perhaps, the health and safety risks involved with the use of high voltage current. Low voltage electrical resistance heating and induction heating are the two most commonly used methods. High velocity gas burners are more advantageous when large areas need to be heat treated, particularly if, for example, firing can take place within a pressure vessel which then becomes its own furnace. For local PWHT of vessel circumferential seams internal insulating barriers can be used to localise the heat source. Motorised valves and microprocessor control of the combustion conditions enabled precise management of the heating cycle to be achieved. Low voltage electrical resistance heating uses flexible ceramic heating elements, colloquially known as corsets, an appropriate number being assembled to cover the area to be heat treated. Induction heating uses insulated cables that can be wrapped around the joint or shaped to fit the area to be heated or specially designed fitting for repetitive PWHT operations as illustrated in Fig 1. To perform the PWHT, temperature control thermocouples are firstly attached, often by capacitor discharge welding, the elements placed in position and the area then lagged with thermal insulating blankets to reduce heat loss and to maintain an acceptable temperature gradient. 1 P a g e

There are no standard terms used to describe the various regions within the locally PWHT'd area. In this article the terms 'soak band', 'heated band', 'gradient control band', 'temperature gradient', which may be axial and through thickness, and 'control zone' as suggested by the ASME will be used (see Fig 2). The soak band is the area that is heated to, within the specified PWHT temperature and time range. It comprises the weld, the two HAZs and part of the surrounding parent metal. The heated band is the area covered by the heating elements, the temperature at the edge of the heated band generally being required to be at least half that of the soak temperature. The temperature gradient control band is the region where thermal insulation, perhaps supplemented by additional heating elements, is applied to ensure that an acceptable axial temperature gradient is achieved from PWHT temperature to ambient. A control zone is the region where a number of heating elements are grouped together and controlled by a single thermocouple, enabling different regions to be heated independently; particularly useful with large diameter items or where there are variations in thickness. Temperature gradients may be axial (along the length of a pipe or vessel) and through thickness. The through thickness temperature gradient is caused by heat losses from the internal surface and is a function of both thickness and internal diameter, the larger the diameter, the greater the effect of radiation and convection losses. Both the width of the soak band and the temperature achieved can be substantially less than that on the outside of the pipe or tube. Insulation on the inner surface will reduce the temperature/width differential but may not be possible on small diameter tubes or pipework systems. This through thickness gradient is one of the reasons that specifications and codes require the soak or heated band to be a minimum width, generally related in some way to the thickness of the component. As mentioned above, there are rules in the application codes concerning the size of the heated area, normally related to the thickness. In a circular component such as a pipe butt weld or a pressure vessel circumferential seam the width of the band is easy to calculate. ASME VIII for instance requires the soak band width to be twice the thickness of the weld or 50.8mm either side of the weld, whichever is the lesser. 2 P a g e

ASME B31.3 requires the soak band width to be the weld width plus 25.4mm either side of the weld. BS EN 13445 does not specify a soak band width but instead specifies a heated band width of 5 Rt centred on the weld and where R = component inside radius and t = component thickness. There are no requirements in the ASME codes regarding heated band width. A very approximate rule of thumb for flat plate is that the heated band should be a minimum of twice the length of the weld although practical considerations may prevent achieving this ideal. There are no requirements, in any code or specification, on the width of the thermally insulated band although BS EN 13445 recommends 10 Re. It is essen al that the relevant specifica on is referred to for specific guidance on what is required and it is worth remembering that the specification requirements on soak or heated band widths are minima and very little is lost by ensuring the specified dimensions are comfortably exceeded. What is an acceptable axial temperature gradient? Again, there is little advice in the codes and specifications. It is generally assumed that if the temperature at the edge of the heated band is above half that of the soak temperature then the temperature gradient will not be harmful. During heating and cooling BS EN 13445 specifies a maximum temperature difference of 150 C in 4500mm below 450 C (1 C in 3mm) and 1000C in 4500mm above 4500C (1 C in 4.5mm). To ensure that gradients and temperatures are controlled within acceptable limits sufficient thermocouples need to be attached to provide both temperature control and recording. For small diameter tubes, eg less than 100mm diameter, one control zone and one recording thermocouple are regarded as sufficient; between 100-200mm one control zone and one recording thermocouple at each of the 12 o clock and 6 o clock positions; above 250mm diameter one control zone and one recording thermocouple at each 900 quadrant, 12, 3, 6 and 9 o clock, are suggested. These thermocouples should be placed on the centre line of the weld. Thermocouples will also be needed at the edge of the soak band and the edge of the heated band. Ideally, thermocouples should also be placed on the opposite surface to the heating elements to ensure that the correct through thickness temperature has been achieved although this is rarely possible on pipe systems. It is advisable to double up on the thermocouples to cope with the possibility of a thermocouple failure. 3 P a g e

Thermocouples use a hot and a cold junction to measure the temperature, the hot junction being attached to the component, the cold junction within the temperature recorder. For accurate temperature measurement the hot junction must obviously be at the temperature of the component. Errors can be introduced if the junction is not firmly attached, either by capacitor discharge (CD) welding, by mechanically fixing the wires to the component or by overheating of the thermocouple junction. CD welding of the thermocouple wires gives the most accurate results, particularly if the two wires are separated by 3-4mm. Mechanically attached wires will probably need to be insulated by covering the junction with heat resistant putty to prevent overheating of the thermocouple by the overlying heater. If the wire covering is stripped back then the bare wires also need to be insulated. It is advisable to specify the positions of the thermocouples on a drawing and to include these within a formal written heat treatment procedure document that covers both the specification and best practice requirements. Fig 1. Induction PWHT of Pipework 4 P a g e

Fig 2 Schematic of Temperature bands within a local PWHT (Reproduced with permission of the American Welding Society (AWS), Miami, Florida, USA) 5 P a g e