Multiscreen Vacuum Manifold User Guide for ZipPlate micro-spe Plate

Similar documents
High Output Vacuum/Pressure Pump

Agilent Vac Elut SPS 24 Manifold User Guide

ACQUITY UPLC HT Column Heater Instructions

Mariner Microspray and Low-Flow Electrospray Fused Silica Spray Tip and Capillary Kit. Operating Instructions. 1 Product Description.

DPM-G DPM-CR DPM-W DPM-B INDOOR DOME PENDANT MOUNT INSTALLATION MANUAL

TECHNICAL INSTRUCTIONS

HW-17 Record Cleaning Machine Setup and Instruction Manual

Eldex Column Heater. Operator s Manual

INSTALLATION. Glass Panel Doors (select models) CAUTION

TECHNICAL INSTRUCTIONS

Rapidly process up to 20 samples without the need for repeated centrifugation steps.

INSTALLATION & OPERATING INSTRUCTIONS

MC-UG Vacuum Cleaner. Specifications are subject to change without notice for further improvement. Order Number MAC CE

TECHNICAL INSTRUCTIONS

REMOTE FAUCET PUMP SYSTEM

Universal NanoFlow Sprayer Installation and Maintenance Guide

FEI Nova 200 Dual Beam system maintenance

Heat Exchanger Block Replacement Instructions

TECHNICAL INSTRUCTIONS

Harvester Operation and Service Manual

RYLE WIDESPREAD FAUCET INSTALLATION

TECHNICAL INSTRUCTIONS

TECHNICAL INSTRUCTIONS

CryoFit. Handling of Flow Cell and Capillaries. User Guide. Version 002

Chemical resistant Vacuum Pumps

MC-UL Vacuum Cleaner. Specifications are subject to change without notice for further improvement. Order Number MAC CE

MC-V Vacuum Cleaner. Specifications are subject to change without notice for further improvement.

FIREPLACE INSTALLATION

Model Series. PumpAgents.com - buy pumps and parts online QUIET - FLUSH ELECTRIC TOILET. Model Series FEATURES SPECIFICATIONS INSTALLATION

TECHNICAL INSTRUCTIONS

MAKAI WIDESPREAD FAUCET INSTALLATION

CAR-MON DUST COLLECTORS SERIES 207, 2410, 3015

Suits all KPF849 models

ACQUITY UPLC H-Class Column Compartments Operator s Overview and Maintenance Information

GelCap SL. GelCap SL splice cover kits quickly and con-veniently insulate, seal, and protect stub splice connections up to 1000 volts.

Dry, oilfree Diaphragm Pumps

TECHNICAL INSTRUCTIONS

Dry, oilfree Diaphragm Pumps. Highlight NEW MPC 302 Z. 3 Diaphragm Pumps

The Marine Throne. Model TMT S/37045/X-Series QUIET - FLUSH ELECTRIC TOILET. "all the comforts of home" FEATURES SPECIFICATIONS INSTALLATION

Mounting Instructions Adapter for ventilation duct BWP-143A-SS, Stainless Steel version

English, French & Spanish No Color

Methods of solid phase extraction. Methods of solid phase extraction

owners manual mara washlounge #1408 MARA comfortel.com.au

2006G2 OPERATING INSTRUCTIONS. 2006G2 Pressure-Vacuum Hand Pump July 2011 SOILMOISTURE

HE220, HE260 Humidifier Installation Kit

Series RFII 5.6 K-factor. Flush II Concealed Pendent Sprinklers

MCD. Corona Discharge Ozone Generators MANUFACTURED BY Bullock Lane San Luis Obispo, CA

Installation, Operation and Maintenance Instructions

COR-20 STANDALONE MAIN TITLE GOES MODE USER GUIDE HERE

Product Guide for Ludger Clean Post-endoglycosidase and Post-exoglycosidase Clean-up Plate

Installation, Operation and Maintenance Manual for Model 8331 Condensate Accumulator

Please Read and Save These Instructions.

OPERATION and MAINTENANCE INSTRUCTION MANUAL. ADU-20B CompriCart

Air Purifier. User s Guide. Important! Oreck Air Purifier with HEPA Filtration. Read this manual carefully, and keep for future reference.

HE120, HE160 Humidifier Installation Kit

Chargebuster Ion Gun Installation, Operation and Maintenance

Figure 1. Proper Method of Holding the ToolStick. Figure 2. Improper Method of Holding the ToolStick

Bridge to Splice Presser 710-BSP

Operator s Manual. The FREEDOM ROCKER. Contents. Congratulations!

Non-Programmable Digital Thermostat

INSTALLATION. and INSTRUCTION MANUAL. for QUALITY AIR BREATHING SYSTEMS. Model ABM - 700

Fleck 2510 Sediment Filter Installation & Start-Up Guide

ULTRA-MAX GAS RADIANT CHARBROILER. ULTRA-MAX GAS LAVA ROCK CHARBROILER MODELS 8024CBB, 8036CBB, 8048CBB, 8060CBB, and 8072CBB

3 Scotch Mini-Weld Adhesive System User s Manual

Fixtures Installation

INVERTER SPLIT - TYPE

Automação de SPE utilizando sistema robótico Triplus RSH autosampler. Nova Analitica

Replacing a Gun Thermostat

RIOS 3 USER MANUAL MILLIPORE

OWNER S MANUAL. Important: Read carefully before assembly and use. PORTABLE CANISTER U #961A00007 ID111867

FLUSH WATER SAVER DUAL FLUSH KIT

MAYFIELD CEILING FAN LISTED E ITEM # MODEL #BTH44ABZC5C BTH44BNK5C Español p. 20 ATTACH YOUR RECEIPT HERE.

KEEP FOR FUTURE REFERENCE 1 SCFM NOMINAL AIRFLOW SINGLE VACUUM SYSTEM DC-VOLTAGE POWER SYSTEM WITH MANUAL VALVE

Parasitic Cysts - Cryptosporidium and Giardia, Chemicals, Heavy Metals, Dissolved Salts, Offensive Tastes and Odours, Sediment, Dirt,

ILLUSION 11.2 K-factor Extra Large Orifice Concealed Pendent Sprinklers Quick Response, Standard Coverage General Description

Single-Control Lavatory Faucet

86BSD Digital Output

Electron Microscopy Sciences

MST, INC. MODEL 2002 CARBON MONOXIDE MONITOR OWNER S MANUAL

SKJ. Specifications. Stroke Range Options 250 inches (6.4 m), 400 inches (10.2 m)

Carbon Rack Enclosure

OWNER S MANUAL. Installation Operation Maintenance. Saturn Equipment

PORTRAIT LITE VITREOUS CHINA REVERSE TRAP TOILET

KC22/32 SERIES Sealless Non-Metallic Centrifugal Pumps Installation and Maintenance Instructions

CONSUMER SERVICES TECHNICAL EDUCATION GROUP PRESENTS

Operator s Manual. The Bullet Blender 50 BB50-AU, BB50-DX. Contents. Congratulations!

Chargebuster Ion Gun Installation, Operation and Maintenance

DRAIN WATER TEMPERING INSTALL

Basin Set INSTALLATION INSTRUCTIONS

Instruction Manual GP110 GelPump

Installation. Leveling

Torrena 42 Ceiling Fan

Installation Instructions

Installation and Operating Guide Document No Vacuum Chambers Copyright 2017 Terra Universal Inc. All rights reserved.

MODEL SK2660 COMPRESSOR SERVICE KIT. For use on 2660 and 2680 Model Compressors

Camarillo 52 Ceiling Fan

CT500 Electronic Thermostat

60 Liter Infinity Storage Reservoir

COVER MODEL# GVS415 VACUUM SEALER FOOD PRESERVER. PHOTO OF PRODUCT

OWNER S MANUAL M-1 CASE TUMBLER

Transcription:

Multiscreen Vacuum Manifold User Guide for ZipPlate micro-spe Plate

Notice The information in this document is subject to change without notice and should not be construed as a commitment by Millipore Corporation. Millipore Corporation assumes no responsibility for any errors that may appear in this document. This manual is believed to be complete and accurate at the time of publication. In no event shall Millipore Corporation be liable for incidental or consequential damages in connection with or arising from the use of this manual. 2 Multiscreen Vacuum Manifold User Guide

Contents Preparation of Vacuum Manifold... 4 Unpacking the Vacuum Manifold... 4 Parts and Functions of the Vacuum Manifold... 5 Installing the Support Grid... 7 Assembling the Vacuum Manifold... 8 Installing the Vacuum Pressure Gauge... 9 Configuring the Vacuum Manifold System... 10 Aligning Collection Plates... 11 Ordering Information... 12 www.millipore.com/zpmfld 3

Preparation of Vacuum Manifold Before using the manifold, unpack the components and set them up according to the procedures outlined in this section. Unpacking the Vacuum Manifold Unpack and ensure that you have the following parts of the vacuum manifold: Vacuum manifold base with quick disconnect body Ring assembly with gaskets, bleeder valve, and support grid Straight connector with quick disconnect coupling insert 3-way connector with quick disconnect coupling insert Vacuum ON/OFF valve with tubing Vacuum control valve with tubing Vacuum pressure gauge with tubing FEP-lined PVC tubing Plate alignment tabs Hex key wrench 4 ZipPlate-micro SPE Plate Vacuum Manifold User Guide

Parts and Functions of the Vacuum Manifold D E H C F G J K L M I A B N Letter Part Function A Vacuum Manifold Base Supports standard or deep well ring. B Quick Disconnect Body Allows straight or 3-way connector to be attached to manifold base. C Plastic Ring, standard well Holds gaskets and manifold support grid above the manifold basin to allow the use of standard receiver plates. D Manifold Support Grid Supports plate during filtration. Must be used. E Vacuum Manifold Gaskets Seal manifold support grid and ring to prevent leakage. F Bleeder Valve Fits into ring when pressure gauge is not in use. www.millipore.com/zpmfld 5

Parts and Functions of the Vacuum Manifold, continued Letter Part Function G Plate Alignment Tabs Allows the correct alignment of undersized receiver plates. H Vacuum Pressure Gauge Measures vacuum pressure in plenum. I On/Off Valve Opens or closes valve to vacuum source. J Three-Way Connector Replaces straight connector to allow use of both the on/off valve and the vacuum control valve. K Vacuum Control Valve Controls amount of vacuum pressure. L Hex Key Removes or replaces the bleeder valve. M Straight Connector Connects manifold to vacuum source using the on/off valve and tubing. N FEP-lined PVC Tubing, Connects assemblies to vacuum pressure pump or vacuum 1/4" I.D. source. 6 Multiscreen Vacuum Manifold User Guide

Installing the Support Grid The stainless steel support grid provides alignment for the plate during vacuum procedures. The vacuum manifold kit includes the support grid already assembled in the ring. However, if the grid becomes dislodged, you must install it in the gasket. The support grid and the top gasket have complementary tabs/slots that align the two parts properly. In addition, the grid has an "up side" label stamped on one side. When correctly oriented, this label should be facing the operator when looking down at the assembled manifold. Pull out on the sides of the ring while simultaneously pressing down on the grid. When properly installed, the grid and gasket mate tightly, and remain in place during routine procedures. Pull Frame Outward Press Grid Tabs firmly into Gasket Slots Alignment Tab Alignment Slot www.millipore.com/zpmfld 7

Assembling the Vacuum Manifold 1. Push the coupling insert on the end of the three-way connector into the quick disconnect body on the side of the manifold base until it clicks. 2. Push the end of the ON/OFF valve tubing as far as it will go onto the end fitting of the three-way connector. 3. Push the end of the vacuum control valve tubing as far as it will go onto the top fitting of the three-way connector. Filter-Pump Protection A 1 Vacuum Manifold MultiScreen Vacuum Manifold Vacuum Flask Trap Pump 8 Multiscreen Vacuum Manifold User Guide

Installing the Vacuum Pressure Gauge 1. Remove the bleeder valve from the side of the ring using the hex key wrench provided. NOTE: Do not lose the bleeder valve because the manifold will not operate correctly without it when the vacuum pressure gauge is removed. 2. Attach the pressure gauge by screwing its connector into the ring. Use the connector that projects perpendicular from the pressure gauge tube. The built-in vacuum release valve at the end of the tube will hiss during operation. NOTE: Do not overtighten the connection. No more than four rotations are required. www.millipore.com/zpmfld 9

A 1 Configuring the Vacuum Manifold System 1. Place the vacuum manifold on a lab bench in a stable area unaffected by vibrations from the pump (or any type of shaker). NOTE: Do not place vacuum pump on the same surface as the manifold. 2. Connect your laboratory vacuum source to the vacuum manifold using the tubing provided. NOTE: Allow plenty of room to set up the system to avoid crimping the tubing, which would reduce air flow. Crimping can also cause the lining of the tubing to crack, leading to the loss of solvent resistance. If your tubing does crimp, cut it off below the crimp and reconnect. 3. Place a Millex -FG 50 filter and a vacuum flask trap in the vacuum line to protect the vacuum source from contamination. Your configuration should look like this: Filter-Pump Protection Vacuum Manifold MultiScreen Vacuum Manifold Vacuum Flask Trap Pump 10 Multiscreen Vacuum Manifold User Guide

Aligning Collection Plates (for Vacuum Elution Procedure only) The vacuum manifold comes with two plate alignment tabs that will need to be installed. These tabs align the wells of the filtration plate with the wells of the collection plate. Install the plate alignment tabs as follows: 1. Remove the two alignment tabs from the shipping bag. 2. Position the tabs with the shorter sides pointing up. 3. Insert the tabs in the manifold base by gently pressing them into the tab slots. Please read the entire protocol before processing your samples. www.millipore.com/zpmfld 11

Ordering Information Description Quantity/Pack Catalogue Number MultiScreen Vacuum Manifold 1 MAVM 096 0R ZipPlate micro-spe Plate 10 ZPC 180 010 Montage In-Gel Digest ZP Kit 1 LSKGDZ P96 MALDIspot Kit 1 LSKZPMS96 Vacuum pump, 220 V 1 WP6122050 Vacuum pump, 110V 1 WP6111560 Millex FG50 Vacuum Pump Filter Guard 10 SLFG 050 10 2003 MILLIPORE CORPORATION. ALL RIGHTS RESERVED. THIS BOOK OR PARTS THEREOF MAY NOT BE REPRODUCED IN ANY FORM WITHOUT THE WRITTEN PERMISSION OF THE PUBLISHERS. P36524, Rev., 06/03 Millipore, Montage, Multiscreen, ZipPlate and Millex are registered trademarks of Millipore Corporation. MALDIspot is a trademark of Millipore Corporation. 12 Multiscreen Vacuum Manifold User Guide