Greenleaf 400 Macerator Toilet Waste Pump Instruction Manual

Similar documents
Greenleaf 600 Macerator Toilet Waste Pump

Greenleaf 100 Toilet Macerator Waste Pump Instruction Manual

Sanipack is a compact pump/macerator specially designed to take the waste from a wall hung or back to wall WC pan.

Manual. WilTec 3/1 Macerator Toilet Pump System Article 50741

Please also see 10 golden rules for correct Saniflo installation on

WC2 & WC3 Installation & Maintenance Instructions

2 SPEED PUMP INSTRUCTION MANUAL READ THIS MANUAL CAREFULLY BEFORE USING YOUR 2 SPEED PUMP

MAXI PUMP INSTRUCTION MANUAL NE6151B /NE6171B READ THIS MANUAL CAREFULLY BEFORE USING YOUR MAXI PUMP

SUBMERSIBLE WATER PUMPS

TIDALWAVE I/G POOL PUMP INSTRUCTION MANUAL

INSTALLATION AND CARE INSTRUCTIONS

Operation Manual. Trash Water Pump ARTICLE Image similar

INSTALLATION AND CARE INSTRUCTIONS

SolidFlo G2 Solid Handling Pumps Product Manual

CLEAN WATER PUMP. MODEL No: Hippo4A OPERATION & MAINTENANCE INSTRUCTIONS. Part No:

Issue 4 Oct Panamatic Top loading Maxi & Optima 3 Installation

Laing Thermotech. Autocirc The Instant Hot Water Pump Models E1-BCANCT1W-06 and E1-BCANRT1W. Installation & Operating Manual

VADA - Rain2Main Automatic Rainwater Controller

INSTALLATION MANUAL GUTHD2. Universal Two Way Digital Thermostatic Valve for Shower Systems

USING YOUR PRESSURE SEWER SYSTEM

Paper Shredder. Installation & User Instructions Please keep for future reference 913/0153

8L DEHUMIDIFIER OPERATING INSTRUCTIONS

Zip Hydroboil. Installation and Operating Instructions. Filtered instant boiling water

CPE RANGE PUMPS CPE RANGE PUMPS. MODEL Nos: CPE15A1 15A3 20A1 20A3 30A1 30A3 PART Nos:

INSTALLATION AND CARE INSTRUCTIONS

WALLACE MAXIPUMP 3000, 5000, 6000 and HYDROJET 30P, 30C, 140 AND HJ400 INSTALLATION AND MAINTENANCE INSTRUCTIONS

PUDDLE PUMP PUDDLE PUMP. MODEL No: PSP125 OPERATION & MAINTENANCE INSTRUCTIONS. Part No:

Operating Instructions

SH3020 USER INSTRUCTIONS

2.9kW Portable Air Conditioner

Model: C C Ambassador 20. Automatic Carpet Scrubber OPERATION SERVICE PARTS CARE

SG-DEH-PEX Vertical Dehumidifier Pump Operating Instructions

12L DEHUMIDIFIER OPERATING INSTRUCTIONS

Electric Pressure Washer

80cm Tower Fan With Remote Control

2.9kW Portable Air Conditioner

OPERATION & MAINTENANCE INSTRUCTIONS

NT1-P CONDENSATE NEUTRALIZATION TANK WITH PUMP INSTALLATION, OPERATION, AND MAINTENANCE INSTRUCTIONS

Food Waste Disposer Instruction Manual

A few simple steps to ensure perfect water, every time.

A4 Laminator. Installation & User Instructions Please keep for future reference 908/6197

PORTABLE AIR CONDITIONER

A few simple steps to ensure perfect water, every time.

Pear Kitchen Sink Tap

General Care and Safety Guide

CRAFTSMAN EXAMINATION, JUNE 2007 PLUMBING ANSWER SCHEDULE

EVAC Commercial Marine Equipment TOILET TECHNICAL DATA EVAC 90, SQUATTING TOILET. To main vacuum line, connection Ø50.

OWNERS INSTRUCTION MANUAL

CLEAN WATER SUBMERSIBLE PUMP

Operation Manual. Pond Pump Series HJ and CQP

Electric Pressure Washer

Macerator Pumps & Lifting Station. Technical presentation Part 1

OUTDOOR DISHWASHER INSTALLATION INSTRUCTIONS

MULTI Hand Vacuum USER GUIDE 1985 SERIES

Operating Instructions

DEHUMIDIFIER MODELS: SD-30E / SD-40E / SD-65E INSTRUCTION MANUAL

INSTALLATION OPERATION MAINTENANCE LANCASTER MODELS X99M33 & X99M50

Instruction Manual for Electric Marine Toilets LT-0E and LT-1E

20L Electronic Dehumidifier

REGISTRATION EXAMINATION, JUNE 2015 LICENSED PLUMBER QUESTION AND ANSWER BOOKLET. Time allowed THREE hours

Self-Containment Of Motor Caravans

FAULT FINDING. Water Gas Cassette Toilet FAULT FINDING

10L Evaporative Cooler with Timer

WARRANTY POLICY & RECOMMENDED MAINTENANCE

Zip Econoboil. Installation and Operating Instructions. Budget priced instant boiling water for canteens and kitchens.

Autofill wall mounted water. boiler. Getting the best from your water. boiler. Please read and keep these instructions

Target Monobloc Kitchen Mixer Chrome

MULTI REACH Stick Vacuum

PANTHER. Condensate removal pump Installation and operating guide

Minimalist Bottom Outlet Thermostatic Bar Shower. Telephone Product Specification

Installation and Operating Instructions. Budget priced instant boiling water heater for beverages.

Air Pump Up to 800 gallons

User Guide. Fixed Flow Pumps FOR SUBMERSIBLE OR INLINE USE FOR PUMP MODELS # # # # # # # # #728333

Dove Eco thermostatic bar mixer shower

Oltis thermostatic bar mixer

Manual and Thermostatic Power Shower Units

EFX 600. aquamanta. Instruction Manual. 4year guarantee. the experts in aquatic technology. >600 Litres

GRUNDFOS INSTRUCTIONS. Sololift2 C-3. Installation and operating instructions

T550i power shower pump Installation and operating instructions

CF1400 DO NOT RETURN PRODUCT TO PLACE OF PURCHASE. IF YOU HAVE ANY QUESTIONS, CALL OUR TOLL FREE HOTLINE:

WARRANTY TABLE OF CONTENTS TECHNICAL SPECIFICATIONS. Product Warranty Always keep your receipt as proof of purchase. Technical specifications...

DIRTY WATER SUBMERSIBLE PUMP

Installation instructions for the T 9820 Gas Dryer

AMBION FLAME. INSTALLATION AND USER INSTRUCTIONS

Installation Instructions. For the 18 Built-In Dishwasher and Front Color Panels

PRESSURE WASHER MODEL NO: JETSTAR 1750 OPERATION & MAINTENANCE INSTRUCTIONS. WARNING Read the instructions before using the machine PART NO:

DIRTY WATER SUBMERSIBLE PUMP KIT

Model Series. PumpAgents.com - buy pumps and parts online QUIET - FLUSH ELECTRIC TOILET. Model Series FEATURES SPECIFICATIONS INSTALLATION

Sanitaire. Owner s Guide. 10 GALLON Box Extractor SC6088 Series IMPORTANT

FOOD WASTE DISPOSER Owner s Manual & Installation Instructions

Cable Drum Machine. Operation Manual 40 SERIES. Cleans 2" to 4" lines up to 75' N O T F O R R O O T S

Model No: Little Devil II (inc ss)

breeze easytm model # F100-1W

Bath Shower Mixer

Home owner s manual Pressure sewerage system

Installation Instructions & Operating Manual

Installation and Operation Manual. ACF-18 Automatic Chlorinating Feeder

Read All Instructions Thoroughly Before Installing or Using the Disposer.

ProAction. Paper Shredder. Installation & User Instructions Please keep for future reference 903/1537

7Litre Evaporative Cooler With Remote

Transcription:

Greenleaf 400 Macerator Toilet Waste Pump Instruction Manual Website: Contact: www. greenleaftrade.co.nz greenleaftraders@gmail.com Greenleaf 400 Macerator Toilet Waste Pump

Introduction The Greenleaf 400 toilet macerator pump is suitable for use in domestic waste / sewerage installations. The unit can be connected to a standard toilet, shower, vanity and sink unit. It is not recommended for use in conjunction with waste disposal units unless a filter system is fitted in the waste line to screen out any solid foreign objects. The unit can be used in hair salons but again filtering is required to remove any hair that might enter the unit. The unit has two 40 mm inlets on both the lower left and right side of the unit and a discharge port on the top right of the unit. There is a 85mm toilet connection on the front of the unit. The unit has an override switch on the top left of the pump, a carbon vent on the top right and an extra inlet connection on the top left. Operating Principal The macerator unit comprises a tank that stores the waste products/wastewater and an electric powered pump, which grinds and pumps the waste product. The unit is automatically controlled and operated via a pressure switch.

The pump will start operating when activate by the pressure switch due to either flushing of a toilet or water flowing into the storage unit from a shower, vanity or sink. Foreign Objects To ensure continued reliability of the macerator unit, only organic toilet sewerage, water and toilet paper should be passed through the system. No other liquids or solids should be allowed to enter the pump. Other items can cause the pump to clog and malfunction or to seize the motor. The maximum temperature of the pumped fluid should not exceed +50*c in permanent operation. The pump must not be used for flammable liquids, gas emitting liquids, explosive liquids, fuel, cleaning agents or any other chemical products. Technical Data Power Supply 230V / 50 Hz Power Consumption 400 watts Water Temp Range Minimum 1*C to max 90*C Normal Operating Temperature Max 50*C Max Input Flow 100 litres/ min Max Lift Height 8 metres Max Horizontal Distance 80metres Waste Water Connection 1 x 85 mm Waste Water Connection 2 x 40 mm Waste Discharge Line 1 x 40 mm 1% 8m 7m 6m 5m 4m 3m 2m 1m max10m max20m max30m max40m max50m max60m max70m max80m Safety Warning Please read all the safety guidelines and instructions. Non- compliance with the safety rules and regulations can lead to electric shock, fire or serious injury. The unit is to be used only in the manner described in this instruction sheet.

This unit is not suitable for use in swimming pools, paddling pools, or any form of standing water. The unit must not be situated where it is exposed to direct water or rain. The operation of this unit in any situation other than for its recommended use is prohibited. Children should be supervised to ensure they do not interfere with this unit. Carry out a visual inspection of the unit prior to use and on a regular bases. Do not use the device if it is damaged or defective. Do not override the unit. Prior to carrying out any maintenance on the unit the power cord must be disconnected from the mains supply. If the power cable is damaged it must be serviced and replaced by a qualified electrician. The power requirements for this unit are 230V 50Hz. The supply to this unit must be 230V 50Hz. Never lift or carry the unit by the power cable. Ensure the power plug is connected in an area that is dry and in a flood proof zone. Installation The user is responsible for ensuring that the unit is installed in compliance with any regulations that may pertain to the use of this device. The user / installer will ensure that adequate precautions are taken in regard to protecting the area from flooding / overflow by way of an alarm system or standby pump. The user / installer is responsible for any consequential damage that may arise from installation that may cause flooding, water overflow or any other such event that may occur form the operation of this unit. The supplier accepts no responsibility for any damage caused by non- operation of the unit at any time. It is the user / installer s responsibility to ensure that back up devices and alarms are installed to protect their property at all times. Toilet Waste Connection Inlet The unit can be operated with most standard toilets with a horizontal outflow. The mid point of the horizontal outlet of the toilet should be 180mm from ground level to match the mid point of the pumps toilet inlet connection. A 85mm rubber connection on the front of the macerator assembly is used for the toilet waste connection. The supplied clamping ring should be used when connecting the toilet waste pipe.

Top 40mm Discharge Port This port is located on the top right hand side of the unit. A rubber connector is supplied with the unit to connect to the discharge pipe. The unit is supplied with a right angle rubber connector with a built in non- return valve. Lower Left and Lower Right 40mm Waste Inlet Ports The unit has two inlet ports on the lower left and right ends. These two inlet ports are approximately 55mm from ground level (to centres). Rubber connectors are supplied with the unit for connecting to these ports. Both these inlet ports have non- return valves fitted inside the tank unit. Top Left Side 40mm Inlet Port There is one more inlet port on the top left side. To access this port you will need to cut the solid plastic top off (refer diagram). Pressure Switch Override Button

The pressure switch override button is located on the top of the unit left hand side front when viewing the pump from the front. Depressing this button will override the pressure switch function and cause the motor to run. Care should be exercised when using this feature as it may cause the motor unit to burn out if it is jammed with a foreign object. Dry Running The unit must not be allowed to run dry at any time. The manufacturers warranty is invalid if it is determined that the unit has been run dry. Venting This unit is fitted with an active carbon filter, and requires no external venting. Initial Startup of the Unit Once installation is complete, flush the toilet and check that all seals and connections are watertight. Check both the discharge pipework from the unit and the other sanitary appliances connections. The motor should run for 5 to 10 seconds to clear the waste fluid (depending on the height of the pipe run). If it runs for more than 20 seconds, check that the pipework is clear, and that the discharge hose is not kinked. There should be no dripping of water from the toilet cistern or any other sanitary appliances, as this will cause the unit to activate repeatedly. Discharge Pipework Horizontal pipe runs must have a minimum fall of 1:200 (5mm per metre) to the soil stack. If a vertical lift is required, it must be made before the horizontal run at the start of the pipe run. It is recommended that a drain- off point be installed to allow the discharge pipework to be drained down before any service work. Siphoning If the discharge pipework runs to a level considerably lower than the unit, the resultant syphoning effect can suck out the water seal in the unit. Fitting an air admittance valve at the high point of the pipe run will overcome this problem. Typical Installation

-1% max, 5m -3% -3% -40 Sewer Line Connection The outlet pipe should be connected to a soil stack or waste line. Avoid connecting the outlet pipe to any waste pipe where there is a possibility of the waste back feeding into a sink, shower, vanity etc. Operating at Maximum Pumping Height or Distance The following should be observed if the unit is to be used at its outer pumping limits. Use smooth bends (OR 2 X 45 degree bends together) and not 90 degree elbows if possible. Any elbow on the discharge pipe of the unit will create friction loss (roughly 50 cm per elbow to be deducted from the vertical pumping spec.) Maintenance The pump unit should be removed and cleaned on a regular basis. Soil matter can build up in the collection tank over a period of time and can lead to slow draining of showers, sinks and vanities. This slow draining of the amenity units is usually caused by the build up of soap around the inlet ports on the unit. Trouble Shooting Guide Pump Causes Remedy Slow to discharge or Outlet pipe to long Reposition Pipe Will not discharge Or to high Outlet pipe diameter Replace Pipe

Emits a humming noise But does not discharge the waste To small Partial blockage of outlet Pump blocked or jammed Actuate the pump with Override switch. If Problem persist, pump Is blocked, clear blockage Check pump and Clear blockage Pump cycles continuously Outlet Check valve has failed Clean / replace check Valve Tap or toilet has slow leak Repair the leak Runs Continually Vertical discharge outlet check Reposition check valve Valve to high above the pump Check valve defective Pressure switch defective Replace check valve Check pressure switch No humming noise No Electrical supply Check electrical supply Pressure switch defective Press the manual override button If the pump runs check The pressure switch. If override button has no effect check the pump Motor Pump and Accessories Pack