INTERIOR. Convector Grids INTERIEUR CONVECTOR GRIDS 03/2017 TL EE KO ST E 2

Similar documents
Window fashion by design

Specification Blinds. Disclaimer JASNO reserves the right to change the contents of this document without notice.

PURE WOOD BLINDS TECHNICAL SPECIFICATIONS

faux wood blinds COLLECTION

Normandy Wood Blinds. February Program Reference Guide

Noble. jorel. Sideboard. Room divider. Design: Philipp Mainzer

Normandy Wood Blinds

2 Aluminum & PVC Horizontal Blinds 1, 2 & 2 ½ Basswood Horizontal Blinds 1, 2 & 2 ½ Fauxwood Horizontal Blinds

2 Non-FR Wood Blinds. Toll Free (800) Fax (845)

March, Normandy Wood Blinds. Program Reference Guide

W D. arren rapery. Co. Simply Styled. Custom Fabric Valances, Cornices & Drapery. Exclusive Top Treatment Program Offered By Warren Drapery Company

Plantation SHUTTERS. UK s leading shutters specialist. Est STYLISH, MADE-TO-MEASURE SOLUTIONS

PLEASE READ PRODUCT GUIDE NOTE IN FULL BEFORE COMPLETING ORDER FORM, 1 BLIND PER ORDER FORM, STATE QUANTITY IN BOX PROVIDED BELOW

Acrylic Claw Foot Tub

Specification Blinds. Disclaimer JASNO reserves the right to change the contents of this document without notice.

P R I S M CEILING PRODUCTS COLOR AND FINISH SELECTOR C O L O R

The Altro design collection

INSTALLATION INSTRUCTIONS SINGLE CIRCUIT

INSTALLATION INSTRUCTIONS

P R I S M CEILING PRODUCTS COLOR AND FINISH SELECTOR C O L O R

INSTALLATION INSTRUCTIONS ONE LARGE ZONE

WARM WATER UNDERFLOOR HEATING SYSTEMS. Guidance Notes

EXCLUSIVE. Kelly Hoppen DESIGNER RANGE

Type CODE Speed Heating Cooling

Sunshine Manufactured Structures, Inc.

Drapery, Deluxe Stripes Roman Shades 63% Rayon/37% Polyester 7"H. Cabana Stripe Coffee. Drapery, Deluxe Stripes Roman. Cabana Stripe Crimson

Performance Specifications LSF LIFT-SMOKE-FREE

versatile collect Wardrobe Hallway unit walk-in closets Room divider Display cabinet Design: Heide & Kräling

EGGER DECOR CHANGES. Organised by decor group

Acrylic Claw Foot Tub

RICHMOND. Technical Guide. July. Date of print/release

Steel furniture. Individual equipment for offices. Wertheim 09/2008

Novelties 2019 systemat

CLIMA CANAL HYBRID CLIMA CANAL. Low Water Temperature system LOW TEMPERATURE SYSTEM / HEATING AND COOLING LOW TEMPERATURE SYSTEM / HEATING

GRANGE CAST IRON RADIATORS COMMERCIAL HEATING SOLUTIONS

CONCEALED CEILING SYSTEMS INSTALLATION GUIDE

KITCHEN INSPIRATION 1

Smoke extraction duct of sheet steel

Curtains Accessories

Nut Lounge Chair. Marcel Wanders

REVERSIBLE TH HOBS The TH series hobs can be installed with the knobs facing either frontally or sideways. Ideal for small spaces.

Alfresco & Internal Timber Lining

Water Underfloor Heating Kit

INSTALLATION GUIDE. Isodrive / V2.0

CoziMat. 1. Introduction and Brief Description COZIMAT INSTALLATION INSTRUCTIONS & SAFETY REQUIREMENTS

VANTA and VANTA+ Venetian blinds

Galaxy. series. DOPPLER Cabins

DECORATE WHATEVER COMBINATION YOU LIKE, CONFIDENT IN THE KNOWLEDGE IT LL ALL LOOK GREAT TOGETHER.

WINDSOR. Technical Guide WINDSOR. July. Date of print/release

O.D / 2" (444) 15 1 / 2 " (393) Maximum I.D / 4 " (336) 1 3 / 4 " (45) 1 1 / 4 " (32)

HARMONY COLLECTION. Roman Shades Collection. By Legacy Window Coverings. Pricing and Ordering Information. Revised April 2014

Film-Tech. The information contained in this Adobe Acrobat pdf file is provided at your own risk and good judgment.

DIVISION FURNISHINGS. WINDOW TREATMENTS Page 63 of WINDOW TREATMENTS WINDOW BLINDS

Real Cedar Look Class 1(A) Fire Rating Limited Lifetime Warranty Easy to Install Easy to Maintain

Bead Roller Operating, Servicing, and Safety Instruction Manual

Individual window solutions in aluminum and fine wood.

V Refrigeration Module

PVC BLINDS PVC READY-MADE STANDARD FEATURES

up to 78% CLEARANCE SALE OFF 2 DAYS ONLY Sat-Sun, June 11th & 12th from 10am-6pm

!"" #$% "!&' ( ( ) *

Series 47 Elegance. Custom Made Roller Blinds. Product Information. Elegance Manual - Version Page 1

The new WAREMA external venetian blind 80 S PROVEN THINGS IN PERFECTION

NEPTUNE BY GLOBAL VILLAGE EX-DISPLAY ITEM LIST ALL ITEMS SOLD AS SEEN NO RETURNS - NO WARRANTY DELIVERY CHARGE APPLIES

INSTALLATION. Glass Panel Doors (select models) CAUTION

DECORATIVE ELEMENTS OPTIONS. Add a little flare to your glass structure.

2454 RETRO POP Popcorn Machine Instruction Manual Model #2454

Water Underfloor Heating Kit

INSTALLATION INSTRUCTIONS

6 oz. Kettle Poppers With / Love My Popper Kettle Popcorn Machine Instruction Manual Models: 1871,2660,2661

#PSBTWE1000 INSTALLATION GUIDE

C/S Fire Rated Door Edge Protection Product Range FD60

INSTALLATION GUIDE. Isodrive Revision V1. HOME APPLIANCES

5800 Refrigerator Compressor Capacitor/Relay Kit

Instructions for Colonel Electric Label Gluer

EXTERNAL SCREEN CLASSIC

Concepts. Products. Service. DryMode Simply install tiles dry

Popcorn Machine Instruction Manual Model #2551EX

Galaxy. series. DOPPLER Cabins

Uniclass L442 CI/SfB (34) X. Architectural Handrail and Balustrade. Architectural metalwork systems

PARTS AND SERVICE MANUAL FOR THE 23 COMPACT FIREPLACE

Duet XL /0929. Installation guide

Cooling Strip Model SPB

RIVERA P5000. Folding awning P5000

Introduction OUR RANGE COLOURS PRICE LISTS ORDER FORMS CONTENTS. Metro Manhattan Airo. Interior options. Lacquer glass Wood panel Frame Premium

MAINTENANCE MANUAL TAIYO SEIKI CO., LTD.

THE MARVIN ULTIMATE DOUBLE HUNG NEXT GENERATION

THE MARVIN ULTIMATE DOUBLE HUNG NEXT GENERATION

EN Vitra 2012 PLACE SOFA JASPER MORRISON

Door Styles 4-5. Arlington Aske Highbury Curve Stonebridge Vallance Boundary 50-55

Inspiration PVCu Windows & Doors

2 INCH COMPLEMENTARY COMPONENTS Sept 2017

THE MOST COMPLETE RANGE OF DESIGN LED WARDROBE AND ROOM DIVIDER SOLUTIONS

OPTIMIZED CONVECTION. unique heating technology. Catalogue

Whites & Neutrals. Designed to inspire the interior designer within you. NEW ZEALAND Phone AUSTRALIA. Phone

A Guide to Measuring Shaped Venetian Blinds (and getting it right) Rule No. 1: If in any doubt after reading this talk to us.

Timber Venetians Manual

Assembly- and Usermanual. Rainmaker. Code No GB. Edition: 09/2007

Marley Ultra Quiet Fan

2017 CATALOG proselectcabinetry.com. BEAUTIFY YOUR HOME FOR A LIFETIME with the experts at ProSelect Cabinetry

P-60 and 60 Special. Popcorn Machine Instruction Manual Model #1866, #2085, #2086 and #2656. Cincinnati, OH USA

Transcription:

Convector Grids INTERIOR

Convector Grids Contents 01 Dimensions 02 Specifications 03 Construction Design convector and convector grid Schematic design convector with convector grid 04 Versions

Dimensions Dimensions* A1 A2 B1 B2 C1 C2 Length Convector grids Clear length Convector (order dimension) Width Convector grids Clear width Convector (order dimension) Height Convector grids Clear height (top edge floor) 500 2000 502 2002 100 350 102 352 19 29 20 30 B1 B2 C1 C2 A1 A2 *All information in millimetres

Specifications General Product Information Description Material* Colours Dimensions Ventilation cross section Rod width / rod height** Convector grids constructed from solid rods as heating and ventilation covers for indoor areas with exchangeable single rods Solid oak wood rods with distance bushes made of stainless steel, brass or lacquered black 01 Pearl 02 Beach Shell 03 Honey Gold 04 Cinnamon 05 Antique Ivory 06.001 Oyster Dark 06.002 Oyster Light 07 Smoke 08 Sepia 09 Corn Gold 10 Cognac 11 Havana 12 Mocha 13 Dark Clay 14 Chocolate 15 Black Olive 16 Black Cherry 17 Linen 18 Pebble Stone 19 Drift Wood Length A1: min. 500 mm max. 2000 mm Width B1: min. 100 mm max. 350 mm 58 % 66 %, depending on length and width 9 mm width/height: 20 30 mm incl. glazing tape 1 mm Surface weight Approx. 9.5 kg/m2 at a ventilation cross section of 60 % Alignment Transversely to convector length Load capacity Max. 50 kg/rod at a total width 250 mm Maximum load capacity Installation Construction requirements View into the inspection shaft For normal loads (e.g. walking across) the maximum load capacity depends on the size of the load surface area. This means, that in order to calculate load capacity, the number of the rods to be stressed and the maximum single rod load capacity must be assessed. Example maximum load capacity for 5 rods: 5 x 50 kg = 250 kg (at a convector width of 250 mm) No special installation measures required The convector must be mounted accurately. As of 250 mm width, a site-side support will be required. Increased requirements for planarity according to DIN 18202, Table 3, Line 4 (increased requirement floors with finished surfaces) With a ventilation cross section of approx. 63 % and a distance starting from approx. 1.40 m and a height of 1.70 m, the view into the inspection shaft will be denied. Special features Glazing tape for acoustic separation of convector and convector grid *oak, other timbers on request **measurements may vary slightly due to production reasons

Construction Design convector and convector grid Bracing nut Convector frame e.g. Möhlenhoff Convector grid rods 9 x 19 mm Ventilation cross section Distance bushes stainless steel/brass/black lacquered A2 Clear length of the recess (order dimension) B2 Clear width of the recess (order dimension) FF* B2 Clear width of the recess (order dimension) *Finished Floor Level B2 Clear width of the recess (order dimension) 1

Construction Schematic design convector with convector grid FF Convector frame e.g. Möhlenhoff Technical unit Convector grid rods 9 x 19 mm Distance bushes stainless steel/brass/black lacquered Connecting joint floor and convector casing 5 10 mm (DIN 18356) Screed/Hollow flooring Schotten & Hansen floorboard with full adhesive bonding 2

Versions Version 01 Standard convector grid with overlapping floorboard* FF Straight convector grid Overlapping floorboard Glazing tape Convector frame *Sound transmission possible (this only applies to non-settled hollow flooring, e.g. Schotten & Hansen underfloor system). 1

Versions Version 02 Notched convector grid (frameless) FF Notched convector grid Floorboard Joint DIN 18356/DIN 4109 Joint material Schotten & Hansen/round cord Glazing tape Convector frame 2

Versions Version 03 Standard convector grid FF Straight convector grid Floorboard Joint DIN 18356/DIN 4109 Joint material Schotten & Hansen/round cord Glazing tape Convector frame 3

Versions Version 04 Standard convector grid in mounted frame FF Straight convector grid Joint DIN 18356/DIN 4109 Floorboard Joint material Schotten & Hansen/round cord L-profile frame Glazing tape 4