Refrigerant Leak Detector

Similar documents
6-1 Installing Batteries 6-2 Automatic Circuit/Reset Feature 6-3 Feature Sensitivity Adjustment

NGD8800 USER S MANUAL

Model C-380. Instruction Manual. Refrigerant Leak Detector. reedinstruments

TEK-Mate. Refrigerant Leak Detector

TEK-Mate. Refrigerant Leak Detector

CLI Refrigerant Gas Leak Detector. User s Guide

Model GD Instruction Manual. Combustible Gas Leak Detector. reedinstruments. www. com

REFRIGERANT LEAK DETECTOR

99 Washington Street Melrose, MA Phone Toll Free Visit us at

SENSIT HXG-2. Instruction Manual For use with combustible gases Gas Leak Detector

GERMANY TEC 'LOGY leak-detect EXPERT

LD910. User Manual. Combustible Gas Leak Detector. Detects all Hydrocarbon and other Combustible Gases. Made in U.S.A. MSHA Approved Intrinsic Safety

Instruction Manual MSI Sensit HXG

testo 316-EX gas leak detector Instruction manual

CD100A COMBUSTIBLE GAS DETECTOR

LS1. Operator Manual. Kane International Ltd

D-TEK Select. Refrigerant Leak Detector

Instruction Manual Electronic Leak Detector. Bedienungsanleitung Elektronisches Lecksuchgerät. Mode d emploi Détecteur de fuites électronique

Model: LD5 Dual Mode Refrigerant Gas Leak Detector. Operating Instructions

User Manual SF6 GASCHECK 6000

III. 99 Washington Street Melrose, MA Phone Toll Free Visit us at OPERATING INSTRUCTIONS

USER MANUAL MINITRACER PORTABLE SNIFFER

Model R9100. REED Instruments Instruction Manual. Ultrasonic Leak Detectortor

Portable Oxygen Monitor OX-07. (Type B) <No Gas alarm type> Operating Manual

YELLOW JACKET. H 2 Tracer Gas Leak Detector. Operations Manual. Detects 5% H 2 in 95% Nitrogen Tracer Gas. Model 69341

SENSIT HXG-2d. SENSIT TECHNOLOGIES 851 Transport Drive Valparaiso, IN Phone: (219) Fax: (219)

actoolsupply.com User Guide Extech RD300 Air Conditioning AC Refrigerant Leak Detector Refrigerant Leakage Detector Model RD300 actoolsupply.

SENSIT HXG-2d Combustible Gas Detector

II 2 G. SENSIT HXG-2d. Ex ib IIB T3 IP20. Suitable for combustible gases such as Methane, Butane, Propane and Natural Gas MADE IN USA

COMBUSTIBLE GAS LEAK DETECTOR PEN

Portable Oxygen Monitor OX-07. (Type A) Operating Manual

LD-5000 REFRIGERANT LEAK DETECTOR

REFRIGERANT LEAK DETECTOR OPERATIONS MANUAL LD-170

GAS-Mate. Combustible Gas Leak Detector

RD99 REFRIGERANT GAS LEAK DETECTOR WARNING!

SF 6 -Leak Pointer Operating Manual (original version) Type-No.: R002

Operating Instructions. Model: LD3 Dual Mode Refrigerant Gas Leak Detector ROBINAIR.COM

testo Leakage detector for gas Instruction manual

Leak-Seeker I Refrigerant Leak Detector

Model ATD Refrigerant Gas Leak Detector. User Manual. Detects all CFC, HFC, HCFC, HFO Refrigerants including blends

Model: LD7 Dual Mode Refrigerant Gas Leak Detector. Operating Instructions

Combustible Gas Leak Detector Instruction Manual

testo Leakage detector for refrigerants Bedienungsanleitung Instruction manual

MODEL OX-07 Type A INSTRUCTION MANUAL FOR RIKEN PORTABLE OXYGEN MONITOR PT0E-0860

LD920. User Manual. H2/N2 Tracer Gas Leak Detector. Detects 5% H2 in 95% Nitrogen Tracer Gas. Made in U.S.A. LeakDetectors-LD920-UserManual.

SENSIT HXG-2d Combustible Gas Detector INSTRUCTION MANUAL Read and understand Instructions before use. PENDING Ex. II3G Ex ic llb T3 IP20

INSTRUCTION MANUAL FOR RIKEN PORTABLE TOXIC GAS MONITOR

INSTRUCTION MANUAL GAS LEAK DETECTOR CD200

Lutron GS-5800 ULTRASONIC GAS LEAKAGE DETECTOR

Safe Operation Manual. Honeywell IQ Force Gas Detector

LD900. User Manual. Refrigerant Gas Leak Detector. Detects all HFO, HFC, HCFC, and CFC Refrigerants including blends. Made in U.S.A.

Confined Space Monitoring. Leak Investigation. Functions 4. Bar Hole Sampling. Line Purge Testing. Actual Size GX-2012

Refrigerant / Combustibles Leak Detector

INSTRUCTION MANUAL CD Fax: (503)

Portable Gas Leak Detector SP-220 Series TYPE F Operating Manual

H-10PM. Refrigerant Leak Detector

ATD-3698 Refrigerant Gas Leak Detector. Owner s Manual

We measure it. testo 316-Ex CH 4 testo 316-1

Chapter 5 Inspection and maintenance

Whisper. Ultrasonic Leak Detector

Operation Manual. (Version 1.5.1)

OPERATING INSTRUCTIONS

Dräger X-am 7000 Multi-Gas Detection

Combustible Gas Leak Detector Instruction Manual

Chapter 5 Inspection and maintenance

IMR IX176 Portable Gas Detector User Manual

T.ex Single Gas Detector VISA

PORTABLE TANKLESS GAS WATER HEATER INSTRUCTION MANUAL GA5MILITAR MODEL

Magnetic Stirring Systems with Heat

Gas leak detectors. For a quick overview. testo testo testo testo gas detector testo 316-Ex.

PR-L2466W- PA. Operating Instructions. High Performance Refrigerator PR-L2466W-PA

RLD-H10P Refrigerant Leak Detector

Gas leak detectors. For a quick overview. testo testo testo testo gas detector testo 316-Ex

Combustible Gas Detection and Control System

PC20-AMFII / PC40-AMF USER MANUAL

XD-125 OWNER S MANUAL COMMERCIAL DEHUMIDIFIER

For technical questions, contact: Grace Engineered Products Inc./ 5001 Tremont Ave, Davenport, IA /

G A S W A TE R /A G U A

This instruction manual explains the use of three models listed on the left.

Model LP USER S MANUAL AND INSTALLATION INSTRUCTIONS

Owner s Manual Super-Slim Four-Way Cassette

Split Portable Air Conditioner

TM-802 Formaldehyde Meter User s Manual

Portable Gas Leak Detector SP-220 Series TYPE FUM TYPE SC Operating Manual

For technical support call:

Indoor/Outdoor Temperature Alert

Owner s Manual. Middle Static Pressure Duct Type MEU-18MPH2 MEU-24MPH2 MEU-36MPL2 MEU-48MPL2 MIDDLE STATIC PRESSURE DUCT TYPE AIR CONDITIONER

Analog Room Pressure Monitor RPC Series

AOYUE 968A+ INT. Deluxe Repairing System INSTRUCTION MANUAL

Installation and Wiring 1.

KSD-35 DR11 KUE-35 DVN11

LD 5000 REFRIGERANT LEAK DETECTOR JB INDUSTRIES INC.

USER MANUAL TPS-M5/M55/M555

User manual INFRARED REMOTE CONTROLLER SIR-15

Feuchtigkeits-Detector Moisture detector. Operating Instructions... 6

TOOLS AND INSTRUMENTS

Refrigerated Compressed Air Dryer

CO warning instruments and gas spillage detectors

PT0E Portable Gas Leak Detector. SP-220 Series. Operating Manual (PT0E-139)

MS-H-Pro-T Magnetic Hotplate-Stirrer with Timer

Transcription:

380 Lo Hi Refrigerant Leak Detector

380-00 JUN. 2007

CONTENT Page 1. GENERAL INFORMATION ------------------ 2 2. FEATURES ---------------------------------------- 2 3. SPECIFICATION --------------------------------- 3 4. OPERATION GUIDE --------------------------- 4 5. PART & CONTROL------------------------------ 5 6. GETTING STARTED---------------------------- 7 6-1 Installing Batteries---------------------------- 7 6-2 Automatic Circuit/Reset Feature--------- 8 6-3 Feature Sensitivity Adjustment---------- 9 7. OPERATING PROCEDURE----------------- 9 8. REPLACING NEW SENSOR-------------- 11 9. CLEANING --------------------------------------- 12

1. GENERAL INFORMATION Thank you for purchasing Refrigerant Leak Detector. Read though the instruction manual before operation for correct and safe usage. Please store and retain this instruction manual for future reference. 2. FEATURES Refrigerant Leakage Detector is the perfect tool for maintaining the air-condition or a cooling system with compressor and Refrigerant. This unit used newly developed semi-conductor sensor which is extremely sensitive to variety of general used Refrigerant. Microprocessor Control with advanced digital signal processing. Multi color visual display. High-Low leak sensitivity selector. Low battery indication. Semiconductor gas sensor. Detection of R-134a, R-410A, R-407C, R22 Freon gas. Carrying case included. 15 (39 CM) flexible stainless probe. Reference Leak source included. Ambient concentration reset. 2

3. SPECIFICATION Detectable Gases: R-134a, R-404A, R-407C, R-410A, R-22 etc. Sensitivity: H L R-22.134a 6g/year 30g/year R-404A,407C,410A 8g/year 40g/year Alarm Method: Buzzer, Tricolor LED bar Indicator. Power Usage: 4 AA size (6V DC) Alkaline Batteries Snake Tube length: 390mm ( 15 ) Dimension / Weight: 173 x 66 x 56 mm ( approximately 400g ) Accessories: Alkaline batteries ( AA) X 4 pcs User manual, leak check bottle, carry case. Battery Life: Approximately 40 hours normal use. Auto power OFF:10 minutes Warm-Up Time: Approximately 90 seconds Operating Temperature & Humidity: 0 ~40 C, < 80% RH 3

Storage Temperature & Humidity: -10 ~60 C, < 70% RH Altitude: < 2000M (6500 ) 4. OPERATION GUIDE (1) The refrigerant leak detector unit is not equipped with anti-explosive designs and measures. Do not use this unit in the environment with the burnable gases. (2) There are some environmental condition that might cause the error reading: Pollutant places. Large temperature variation. Places with high wind velocity. Organic solvent, adhesive vapor, fuel gas and vesicant will cause abnormal response from the sensor. Try to avoid the environment involved with this substance. Places fill with too much to Freon Gas. 4

5. PART & CONTROL 5-1 Panel Description 9 5

1 Sensor 2 Sensor Protector 3 LED Leak Indicators 4 Sensitivity Lo Button 5 Sensitivity Hi Button 6 Low Battery Indicator 7 Power On/Off & Reset Button 8 Battery Cover 9 Battery Cover Screw 5-2 LED Leak Indicator Definition: 6

6. GETTING STARTED 6-1 Installing Batteries Loose the screw and remove the battery compartment door located on the bottom of the instrument As show below (Fig.1). Install 4 AA size alkaline batteries. Reinstall the battery cover by aligning it with the handle. When the batteries are nearing the end of their useful life, the Red LED Low Battery indicator illuminates. The batteries should be replaced as quickly as possible. 4 AA size alkaline batteries Fig.1 7

6-2 Automatic Ambient Reset Feature The Refrigerant leak detectors feature an Automatic Ambient Reset function that sets the unit to ignore ambient concentrations of refrigerant. Automatic Ambient Setup - Upon initial power on, the unit automatically sets itself to ignore the level of refrigerant present at the tip. Only a level, or concentration, greater than this will cause an alarm. CAUTION! Be aware that this feature will cause the unit to ignore any refrigerant present at turn on. In other words, with the unit off if you place the tip up to a known leak and switch the unit on, no leak will be indicated! Ambient Reset Feature - Resetting the unit during operation performs a similar function, it programs the circuit to ignore the level of refrigerant present at the tip. This allows the user to 'home-in' on the source of the leak (higher concentration). Similarly, the unit can be moved to fresh air and reset for maximum sensitivity. Resetting the unit with no refrigerant present (fresh air) causes any level above zero to be detected. 8

6-3 Feature Sensitivity Adjustment The Instrument provides two levels of sensitivity. When the unit is switched on, it is set to the high sensitivity level. To change the sensitivity, press the key. When the key is pressed, the visual display will momentarily show the two left LED's (green) indicating Low Sensitivity level is selected. To switch back to High Sensitivity, press the key. The two right LED's (red) will light momentarily indicating high Sensitivity level is selected. 7. OPERATING PROCEDURE WARNING! Do not operate this instrument in the presence of gasoline, natural gas, propane, or in other combustible atmospheres. How To Find Leaks? NOTE: A sudden whipping of the leak detector probe or "blowing" into the sensor tip will affect the air flow over the sensor and cause the instrument to alarm. (1) Power-Up & Reset function key: The key turns the Refrigerant leak detector instrument ON or OFF and reset function. 9

Press it once to turn on the Refrigerant leak detector, the display will illuminate with flash, for 1.5 minutes to heat up the sensor.. Press it again to reset the ambient base concentration. Press and hold this button for 5 second to turn OFF the power. (2) Verify the condition of the unit and sensor: Set the sensitivity level to Hi. Open the leak check bottle cover and slowly move it closer to snake tube nozzle. If the indication moves up to high from low then we should move the check bottle away and the LED should go off again. This shows that the unit is under working condition. If the unit does not perform as we expect, bring the unit for maintenance at your local sales office. (3) Enter The Measuring Mode Place the tip of the leak-detector probe as close as possible to the site of the suspected leak. Try to position the probe within 1/4 inch (6 mm) of the possible leak source. Slowly move the probe past each possible leakage point. When the instrument detects a leak source, the audible tone will alarm. Additionally, the visual indicators will light from left to right, Green LED 10

then Orange LED then Red LED (highest concentration) as increasing of level indicate that the location is close to the source. When the Instrument signals a leakage, pull the probe away from the leak for a moment, then bring it back to pinpoint the location. If the refrigerant leak is large, setting the sensitivity switch to LOW will make it easier to find the exact site of the leak. Return the sensitivity switch to HIGH before searching for additional leaks. When you've finished leak-testing, turn OFF the instrument and store it in a clean place, protect the leak detector from possible damage. 8. REPLACING NEW SENSOR The sensor had a limited operative period. Under normal operation, the sensor should work more than one year. Expose the sensor under high density of coolant (>30000ppm) will shorten its life cycle rapidly. It is important to ensure that sensor surface is free from water droplets, vapor, oil, grease, dust and any or all other forms of contaminant. Furthermore, to ensure good working condition of the unit, sensors must be replacement periodically when its operative life is over. WARNING! When replacing new sensor, the worn-out sensor may be HOT!! 11

(1) Remove cone cap cover from the tip of snake tube. (2) Pull out old sensor and insert the new sensor into the plug ( see below fig.2). (3) Seal the cap cover over the plug. Sensor protector Sensor Fig.2 9. CLEANING: The Instrument plastic housing can be cleaned with standard household detergent or isopropyl alcohol. Care should be taken to prevent the cleaner from entering the instrument. Gasoline and other solvents may damage the plastic and should be avoided. WARNING! The detergent or isopropyl alcohol might damage the sensor, please keep then from the sensor through the process. 12

CENTER TECHNOLOGY CORP. 4 / F NO. 415, Jung-Jeng Rd., 238 Shu-Lin, Taipei, Taiwan E-Mail : center@centertek.com http : / / www.centertek.com 380-00