WATER DIVISION INSPECTION REPORT

Similar documents
WATER DIVISION INSPECTION REPORT

Inspection Report: Cave City WWTP - Cypress Ln Lift Station, AFIN: , Permit #: AR FACILITY TYPE: 1 - Municipal

WATER DIVISION INSPECTION REPORT

Inspection Report: Berryville Collection System, AFIN: , Permit #: AR FACILITY TYPE: 1 - Municipal

All of the lift stations visited appeared to be clean and well maintained with working alarms and lights.

For additional information you may contact the Enforcement Branch by telephone at or by fax at

RE: Quarterly Inspection conducted on September 6, 2017 AFIN Permit Number 0180-SG-WTX

OPERATION & MAINTENANCE

OPERATION & MAINTENANCE

WATERFRONT FACILITY COMPLIANCE BOOKLET

WORKPLACE INSPECTION CHECKLIST FOR LABORATORY ENVIRONMENTS

ALTA LOMA RIDING CLUB EMERGENCY RESPONSE TEAM ANIMAL EVAC ORGANIZATIONAL CHART EVAC GROUP SUPERVISOR

OPERATION & MAINTENANCE

Stormwater Program Coordinator: Title: Office Phone #: Emergency Phone #: Public Notice Coordinator: Title: Office Phone #: Emergency Phone #:

9S / 9E Inspection Worksheets. The fire department should complete the following sheets prior to inspection date

168 Spotnap Road Charlottesville, VA Tel (434) Fax (434)

Temporary LPG Heat for Construction Sites Work At Risk and Inspection Information Packet

1. Researchers are familiar with the location and contents of: The lab s Chemical Hygiene Plan YES NO

Fats, Oils and Grease Program (FOG)

Inspection Records Schedule- Fire Extinguisher

Joseph Florio, Commissioner of Pub. Works Tel

INFLOW & INFILTRATION REPORT

New Fire Codes and Your Business 2018 WPA Annual Meeting Palm Springs, CA

Full Service Central Station Fire Alarm Listing Evaluation

Eletta Purdy, District Manager, Municipal Licensing and Standards. Municipal Licensing and Standards Folder FEN

WELDING, CUTTING, AND BRAZING SAFETY PROGRAM

FOR THE PERIOD JANUARY 1, TO DECEMBER 31, GENERAL INFORMATION

The Participant will select one of the two Approval Categories (below) and submit the appropriate documentation.

University of California, Davis Laboratory Self-Inspection Checklist

Templates for Maintenance Documents

a) Establishment of emergency procedures to be followed at the time of an emergency;

Access Controls for High Radiation Areas NISP-RP-05

Highlands Region Stormwater Management Program Guidance

Horsham Boil Water Advisory. June 13, 2018

Phase 2 Security Response

South Davis Metro Fire Agency

OHIO UNIVERSITY RADIATION SAFETY REVIEW

LIFT STATION INSPECTION & ASSESSMENT

GUIDELINES FOR INSPECTING GROUND BASED SPARKLING DEVICE (GBSD) RETAIL SALES FACILITIES

Nine Metal Fabrication and Finishing Source Categories 40 Code of Federal Regulations (CFR) Part 63, Subpart XXXXXX (6X NESHAP)

FLORIDA INSTITUTE OF TECHNOLOGY DEPARTMENT OF CHEMISTRY SAFETY MANUAL

CITY OF TOLEDO. Paula Hicks-Hudson. MAYOR Our Division s web-site can be accessed 24/7 at

Testing the System. Battery Test. Dialer Test. Fire Drill Test (Code + [#] + 69) One-Man Fire Walk-Test (Code + [#] + 68)

MANUAL OF ENVIRONMENTAL HEALTH PROCEDURES

ALARM SYSTEMS AND EVACUATION PLANS SELF INSPECTION CHECKLIST

GEORGIA DEPARTMENT OF CORRECTIONS Standard Operating Procedures

El Segundo Fire Department. Unified Program (UP) Form CONSOLIDATED CONTINGENCY PLAN I. FACILITY IDENTIFICATION


CITY OF TOLEDO. MICHAEL P. BELL MAYOR Our Division s web-site can be accessed 24/7 at

Majis Industrial Services SAOC TENDER NO. MISCP/09/2014

Chapter 4: Fire Protection Systems

North Liberty Fire Department Permit Application Temporary Storage & Use of LPG

CHAPTER 05 - OFFICE OF STATE FIRE MARSHAL SUBCHAPTER 05A - FIRE AND RESCUE SECTION.0900 PUBLIC PROTECTION CLASSIFICATIONS FOR FIRE DISTRICTS

STAFF REPORT ACTION REQUIRED

CLARK COUNTY FIRE DEPARTMENT Fire Prevention Bureau

CONSOLIDATED EDISON CO. OF NEW YORK INC. 4 IRVING PLACE NEW YORK, N.Y DISTRIBUTION ENGINEERING CABLE SYSTEMS

Resource, Support, Development, Inc. FIRE EVACUATION DRILL REPORT

FIRE & LIFE SAFTEY STANDARD

Developing Dam Operations & Maintenance Manuals

I. Best Management Practices (BMPs) to Prevent Blockages in the Sanitary Sewer System

ALARM SYSTEMS AND EVACUATION PLANS SELF INSPECTION CHECKLIST

Physical and Environmental Security. CISSP Guide to Security Essentials Chapter 8

Sample Content for the. FlipChart. Example: Medical Facility Emergency Preparedness Guide

dss PHILADELPHIA POLICE DEPARTMENT DIRECTIVE 4.11

Temporary LPG Heat for Construction Sites Information Packet

Demonstration and Training of MEP Systems Page 1 of 15

The Centron Presidio Monitoring System. Centron. Presidio. Rees Scientific. An ISO 9001:2008 Company

LONDON GROVE TOWNSHIP MUNICIPAL AUTHORITY FOG PROGRAM BEST MANAGEMENT PRACTICES

S T A T E O F F L O R I D A D E P A R T M E N T O F J U V E N I L E J U S T I C E BUREAU OF MONITORING AND QUALITY IMPROVEMENT PROGRAM REPORT FOR

Department of Public Safety

CHAPTER LOCAL AMENDMENTS TO THE INTERNATIONAL FIRE CODE 2012 EDITION

PLEASE NOTE! This plan must include: setback dimensions, gas meter location, any obstructions, well and septic

Application for Site Plan Review

Laboratory Inspection Checklist

Point Break for the WSUD Asset Wave. Presentation by Brad Dalrymple

RESOLUTION Adopted this day of, President of June Lake Public Utility District and its Board of Directors

Fire Safety Plan FOR. Business/Property Name: Address: Phone Number: Occupancy Classification. Approved by Fire Inspector: Date:

Funding is available to applicants on a first come, first served basis, and applications will be considered in the order they are received.

Village of Sloan Smoke Testing September 2017

Type of Fire Alarm Control Panel: System is: Existing OR New If new, provide Electrical Permit Number:

CITY OF LONG BEACH Department of Development Services BUILDING AND SAFETY BUREAU FIRE ALARM / ELECTRICAL FIRE PLAN REVIEW CHECKLIST

LOCAL AMENDMENTS TO THE INTERNATIONAL FIRE CODE 2006 EDITION

ADT Select User Manual. 131 ADT ACN

GUARDED STATUS INFORMATION and REQUIREMENTS For OWNERS AND OPERATORS Of REFRIGERATION PLANTS

Emergency Power & Fire Service Checklist

John Jay College of Criminal Justice HOT WORK PERMIT STANDARD OPERATING PROCEDURES

FlexPS. Architectural & Engineering. Specification for FlexPS. Architectural/Engineering Specification for a

1. Accident Prevention

SECTION GAS-FIRED RADIANT HEATERS

[TEMPLATE FOR] STORMWATER FACILITIES OPERATION AND MAINTENANCE PLAN. [date] [revision date]

Site Security Plan - Operations Baron Winds Project

ENVIRONMENTAL STANDARD OPERATING PROCEDURE 7 DEGREASING SOLVENT

The Owner will provide the QEI inspection and certification services.

CALL FOR TENDER - MUNICIPALITY OF THE DISTRICT OF CLARE LITTLE BROOK, N.S.

Attachment F. Campus Capital Needs Sales Surtax Funded Detail Report

TREE REMOVAL PERMIT PACKET

FORM CWM #61 Page 1 . NATIONAL ORGANIZATION SONS OF UNION VETERANS OF THE CIVIL WAR CIVIL WAR MEMORIAL ASSESSMENT FORM

Standard for the Installation of Carbon Monoxide (CO) Detection and Warning Equipment

Liquefied Petroleum Gas Facility Written Fire Safety Analysis

Commercial Business Licensing Requirements

Transcription:

FACILITY INFORMATION NAME: Rogers Pollution Cont. Fac. LOCATION: 4300 Rainbow Road CITY: Rogers RESPONSIBLE OFFICIAL NAME: / TITLE Earl Rausch / Utility Superintendent COMPANY: City of Rogers MAILING ADDRESS: 4300 Rainbow Rd. CITY, STATE, ZIP: Rogers AR 72758 PHONE & EXT: / FAX: (479)273-7378 / EMAIL: WATER DIVISION INSPECTION REPORT AFIN: 04-00155 PERMIT #: AR0043397 DATE: 10/18/2016 COUNTY: 04 Benton PDS #: 093805 MEDIA: WN GPS LAT: 36.29805 LONG: -94.21348 LOCATION: Entrance FACILITY TYPE: 1 - Municipal FACILITY EVALUATION RATING: 5 - Satisfactory INSPECTION INFORMATION INSPECTOR ID#: 104111 S - State DATE(S): ENTRY TIME: EXIT TIME: 10/18/2016 12:30 14:15 FAYETTEVILLE SHALE RELATED: N INSPECTION TYPE: SSO/Collection System PERMIT EFFECTIVE DATE: 1/31/2006 PERMIT EXPIRATION DATE: 2/28/2011 FAYETTEVILLE SHALE VIOLATIONS: N INSPECTION PARTICIPANTS NAME/TITLE/PHONE/FAX/EMAIL/ETC.: Todd Beaver, Plant Manager, City of Rogers Brent Dobler, Operations Manager, City of Rogers Sean Dagstead, Operator/Electrician, City of Rogers Jason Bolenbaugh, Branch Manager, ADEQ Garrett Grimes, District 1 Field Inspector, ADEQ CONTACTED DURING INSPECTION: *** AREA EVALUATIONS (S=Satisfactory, M=Marginal, U=Unsatisfactory, N=Not Applicable/Evaluated) ** PERMIT ** FLOW MEASUREMENT ** STORMWATER ** RECORDS/REPORTS ** LABORATORY ** FACILITY SITE REVIEW S OPERATION & MAINTENANCE ** EFFLUENT/RECEIVING WATER ** SELF-MONITORING PROGRAM ** SAMPLING ** SLUDGE HANDLING/DISPOSAL ** PRETREATMENT ** OTHER: SUMMARY OF FINDINGS No violations were noted during the inspection. GENERAL COMMENTS INSPECTOR S SIGNATURE: Garrett Grimes DATE: 11/7/2016 SUPERVISOR S SIGNATURE: Jason Bolenbaugh DATE: 11/7/2016 Inspection Report Page 1 of 7

COLLECTION SYSTEM INSPECTION AND OVERALL RATING PROVIDE A BRIEF DESCRIPTION OF THE COLLECTION SYSTEM: Rogers collection system services primarily residential areas. System has been continually upgraded since the 1980 s. POPULATION SERVED/NUMBER OF RESIDENTIAL AND COMMERCIAL CONNECTIONS: 60,000 FEET OF SEWER SYSTEM: Approximately 490 miles AGE OF SYSTEM: Continuous updates from 1980 through current. DOES THE SYSTEM EXPERIENCE PROBLEMS DURING DRY OR WET WEATHER (EXPLAIN): Large rain events (10 inches or more) trigger overflows IS THERE A SYSTEM IN PLACE FOR REPORTING SSOS TO ADEQ (DESCRIBE): The facility submits monthly SSO reports to ADEQ. ARE ALL SSOs REPORTED REGARDLESS OF SIZE: HAVE SSOs REACHED WATERS OF THE STATE (LIST DATE AND LOCATION OF EACH): Possibly during large rain events, but this has not been observed. PUMP STATIONS NUMBER OF PUMP STATIONS IN SYSTEM: 18 lift stations and 63 minor stations (only service several households) NUMBER WITH BACKUP POWER: All 18 lift stations have hook-ups for back-up generators. Two (2) mobile generators maintained by the City of Rogers. HOW OFTEN ARE PUMP STATIONS INSPECTED/MONITORED: All 18 lift stations are continually monitored by a SCADA system. Minor stations are inspected every Friday. ARE MAINTENANCE RECORDS AND/OR OPERATOR LOGS KEPT: SCADA logs are kept as well as inventory and maintenance logs. Records kept off-site. ADEQUATE INVENTORY OF SPARE PARTS: Online inventory maintained. Lift stations also have redundancy safeguards in case of equipment failure. TYPE OF REMOTE ELECTRONIC MONITORING USED (I.E. SCADA OR AUTO DIALERS): SCADA BRIEF SUMMARY OF EMERGENCY PROCEDURES: A list of on-call personnel are maintained at the facility to respond to alarms and verify if a dispatch is required. NUMBER OF PUMP STATIONS VISITED DURING INSPECTION (SEE ATTACHED CHECKLISTS FOR EACH): 3 SATELLITE SYSTEMS DOES THE COLLECTION SYSTEM RECEIVE FLOW FROM SATELLITE SYSTEMS: No BRIEFLY DESCRIBE THE SATELLITE SYSTEM: ANY KNOWN PROBLEMS WITH SATELLITE SYSTEM: NAME, ADDRESS AND PHONE NUMBER OF PERSON RESPONSIBLE FOR SATELLITE SYSTEM: Inspection Report Page 2 of 7

PUMP STATION VISIT (COMPLETE A SEPARATE CHECKLIST FOR EACH PUMP STATION VISITED) GENERAL INFORMATION AND OVERALL EVALUATION NAME AND/OR LOCATION OF PUMP STATION: Shadow Valley NUMBER OF PUMPS: 2 + 1 Spare NUMBER OPERATIONAL: 2 NUMBER AND SIZE OF PUMPS APPEARS ADEQUATE: 35 hp EVIDENCE OF RECENT OVERFLOWS OR HIGH LEVELS: GENERAL OPERATION AND MAINTENANCE CLEAN AND WELL MAINTAINED WITH MINIMAL STORAGE OF UNRELATED EQUIPMENT: GATES/DOORS/HATCHES/LIDS/ETC. LOCKED TO PREVENT UNAUTHORIZED ACCESS AND/OR TAMPERING: WET WELLS, SUMPS AND PITS ADEQUATELY COVERED, GRATED OR OTHERWISE PROTECTED: ELECTRICAL CONTROLS COVERS CONDUIT AND EQUIPMENT PROPERLY INSTALLED AND MAINTAINED: GUARDS AND SHIELDS IN PLACE AROUND MOVING EQUIPMENT (BELTS, PULLEYS, DRIVESHAFTS, ETC.) : ADEQUATE VENTILATION TO PREVENT EXCESSIVE CONDENSATION AND/OR GASES AND FUMES: ADEQUATE LIGHTING FOR ROUTINE INSPECTION/MAINTENANCE: SEALS, VALVES AND PACKING ADEQUATELY MAINTAINED TO PREVENT LEAKS: MINIMAL ACCUMULATION OF GREASE AND SOLIDS IN WET WELLS: BACKUP POWER AND ALARMS PROVISIONS FOR GENERATOR AND/OR EMERGENCY TRANSFER PUMP: Mobile generator hook-ups AUDIBLE/VISUAL ALARM WITH EMERGENCY CONTACT INFORMATION POSTED: No notices posted, but on SCADA with visual alarm light. SCADA SYSTEM (LIST PARAMETERS MONITORED): Pump operation, levels, alarms, etc. Inspection Report Page 3 of 7

PUMP STATION VISIT (COMPLETE A SEPARATE CHECKLIST FOR EACH PUMP STATION VISITED) GENERAL INFORMATION AND OVERALL EVALUATION NAME AND/OR LOCATION OF PUMP STATION: Biltmore NUMBER OF PUMPS: 2 + 1 spare NUMBER OPERATIONAL: 2 NUMBER AND SIZE OF PUMPS APPEARS ADEQUATE: 25 hp EVIDENCE OF RECENT OVERFLOWS OR HIGH LEVELS: GENERAL OPERATION AND MAINTENANCE CLEAN AND WELL MAINTAINED WITH MINIMAL STORAGE OF UNRELATED EQUIPMENT: GATES/DOORS/HATCHES/LIDS/ETC. LOCKED TO PREVENT UNAUTHORIZED ACCESS AND/OR TAMPERING: WET WELLS, SUMPS AND PITS ADEQUATELY COVERED, GRATED OR OTHERWISE PROTECTED: ELECTRICAL CONTROLS COVERS CONDUIT AND EQUIPMENT PROPERLY INSTALLED AND MAINTAINED: GUARDS AND SHIELDS IN PLACE AROUND MOVING EQUIPMENT (BELTS, PULLEYS, DRIVESHAFTS, ETC.) : ADEQUATE VENTILATION TO PREVENT EXCESSIVE CONDENSATION AND/OR GASES AND FUMES: ADEQUATE LIGHTING FOR ROUTINE INSPECTION/MAINTENANCE: SEALS, VALVES AND PACKING ADEQUATELY MAINTAINED TO PREVENT LEAKS: MINIMAL ACCUMULATION OF GREASE AND SOLIDS IN WET WELLS: BACKUP POWER AND ALARMS PROVISIONS FOR GENERATOR AND/OR EMERGENCY TRANSFER PUMP: Mobile generator hook-ups AUDIBLE/VISUAL ALARM WITH EMERGENCY CONTACT INFORMATION POSTED: No notices posted, but on SCADA with alarm light. SCADA SYSTEM (LIST PARAMETERS MONITORED): Pump operation, levels, alarms, etc. Inspection Report Page 4 of 7

PUMP STATION VISIT (COMPLETE A SEPARATE CHECKLIST FOR EACH PUMP STATION VISITED) GENERAL INFORMATION AND OVERALL EVALUATION NAME AND/OR LOCATION OF PUMP STATION: Garrett NUMBER OF PUMPS: 3 NUMBER OPERATIONAL: 3 NUMBER AND SIZE OF PUMPS APPEARS ADEQUATE: EVIDENCE OF RECENT OVERFLOWS OR HIGH LEVELS: GENERAL OPERATION AND MAINTENANCE CLEAN AND WELL MAINTAINED WITH MINIMAL STORAGE OF UNRELATED EQUIPMENT: GATES/DOORS/HATCHES/LIDS/ETC. LOCKED TO PREVENT UNAUTHORIZED ACCESS AND/OR TAMPERING: WET WELLS, SUMPS AND PITS ADEQUATELY COVERED, GRATED OR OTHERWISE PROTECTED: ELECTRICAL CONTROLS COVERS CONDUIT AND EQUIPMENT PROPERLY INSTALLED AND MAINTAINED: GUARDS AND SHIELDS IN PLACE AROUND MOVING EQUIPMENT (BELTS, PULLEYS, DRIVESHAFTS, ETC.) : ADEQUATE VENTILATION TO PREVENT EXCESSIVE CONDENSATION AND/OR GASES AND FUMES: ADEQUATE LIGHTING FOR ROUTINE INSPECTION/MAINTENANCE: SEALS, VALVES AND PACKING ADEQUATELY MAINTAINED TO PREVENT LEAKS: MINIMAL ACCUMULATION OF GREASE AND SOLIDS IN WET WELLS: BACKUP POWER AND ALARMS PROVISIONS FOR GENERATOR AND/OR EMERGENCY TRANSFER PUMP: Mobile generator hook-ups. Fence and stationary back-up generator scheduled for installation AUDIBLE/VISUAL ALARM WITH EMERGENCY CONTACT INFORMATION POSTED: No notices posted, but on SCADA with alarm light. SCADA SYSTEM (LIST PARAMETERS MONITORED): Pump operation, levels, alarms, etc. Inspection Report Page 5 of 7

Water Division Photographic Evidence Sheet Location: Rogers Pollution Cont. Fac. Photographer: Garrett Grimes, ADEQ Inspector Date: 10/18/2016 Time: 13:16 Witness: Jason Bolenbaugh, Branch Manager Photo #: 1 Wet well of the Shadow Valley Pump Station. Minimal build-up of solids. Equipment appears to be in good condition. Photographer: Garrett Grimes, ADEQ Inspector Date: 10/18/2016 Time: 13:40 Witness: Jason Bolenbaugh, Branch Manager Photo #: 2 Wet well of the Biltmore Pump Station. Minimal build-up of solids. Equipment appears to be in good condition. Inspection Report Page 6 of 7

Water Division Photographic Evidence Sheet Location: Rogers Pollution Cont. Fac. Photographer: Garrett Grimes, ADEQ Inspector Date: 10/18/2016 Time: 13:57 Witness: Jason Bolenbaugh, Branch Manager Photo #: 3 Wet well of the Garrett Pump Station. Minimal build-up of solids. Equipment appears to be in good condition. Photographer: Garrett Grimes, ADEQ Inspector Date: 10/18/2016 Time: 14:01 Witness: Jason Bolenbaugh, Branch Manager Photo #: 4 An example of a mobile back-up generator hook-up taken at the Garrett Pump Station. This type of hook-up was observed at all three stations visited. Inspection Report Page 7 of 7