LIGHTING LIGHTING. Overhead Electric Distribution Standards INTRODUCTION

Similar documents
SINGLE-PHASE STANDARD

SWITCHING SWITCHING. Overhead Electric Distribution Standards INTRODUCTION

SECTION EXTERIOR LIGHTING

THE COMPLETE GUIDE TO OUTDOOR WALL LIGHTS

High Mast Series HMAO HMSC

OUTDOOR LIGHTING. Features and Benefits O Distinctive, European style with a sleek design

HOLOPHANE. Vector Luminaire. Optimum visibility. Improved highway safety. Outstanding visibility in critical security applications HL /98

Indianapolis Power & Light Company I.U.R.C. No. E-16 Original No. 110 One Monument Circle Indianapolis, Indiana

Arlington. Full Cutoff. Utility Series

REFRACTOPACK. Corrosion resistant construction allows this luminaire to be installed in corrosive and marine outdoor applications.

Full Cutoff. Utility Series

LIGHTING DESIGN STANDARDS SECTION City of Maryland Heights ZONING CODE

HOLOPHANE. Vector Luminaire. Optimum visibility. Improved highway safety. Outstanding visibility in critical security applications HL /98

Explosion Proof Light Watt Metal Halide - Class 1 Div 1 & Class 2 Div 1

PoleStar II HOLOPHANE

FWC APPROVED SEA TURTLE LIGHTING

SECTION LIGHTING

Pro Series LED Lighting Champ LED floodlights. Champ Pro Series. LED floodlights for heavy industrial

Explosion Proof 70 Watt Low Profile LED Light Fixture Lumens - C1D1 Group B - Hydrogen Rated

Post Top Full Cutoff HID

ARTICLE 22, DIVISION 10 LIGHTING

ARTICLE 31 EXTERIOR LIGHTING

elevated ambient capability. in installations where moisture, dirt, dust, vibration, corrosion and rough usage are problems.

Section 7.02 Lighting Standards

Business Customer Information. Account Number (9 digits) Account Holder Name Phone (As shown on your utility bill) Service Street Address

Industrial 100 Watt Ultraviolet LED Light Fixture - Paint Spray Booth Approved Nanometer

ARTICLE 10 EXTERIOR LIGHTING

2. Measurements are to be made at ground level, with the light-sensor portion of the meter lying flat on the ground, pointing upward.

IMPORTANT SAFETY INSTRUCTIONS:

INSTALLATION INSTRUCTIONS

LMV Series W Low Profile - Medium Base

KING LUMINAIRE The K902 Centurion Series Decorative Area Luminaire

Article 14. LIGHTING REGULATIONS

150W Explosion Proof High Bay LED Light Fixture - C1D1&2 - C2D1&2-17,500 Lumens - 60 Beam

MN/DOT Specification Sign Lighting Luminaire With 150 or 250 Watt Metal Halide Lamps 11/05/09

100W Explosion Proof Ultraviolet Portable LED Fixture - 365NM - EXP Cord Caps - 150ft Cord

Dimmable LED Retrofit Kit

C2D1/C1D2 Explosion Proof 50 Watt LED Light Fixture - Paint Spray Booth Approved - 6,250 Lumens

MANDATORY MEASURES OUTDOOR LIGHTING CONTROLS. (Reference: Sub-Chapter 4, Section 130.2)

C1D1 Explosion Proof 50W LED Flood Light Fixture - Paint Spray Booth Approved - Adj Surface Mount

2017 Lighting Incentive

LUMILEDS LEDS - LIFETIME WARRANTY LIGHT DIRECTIONS - UP / DOWN / BOTH

REVISIONS Summary of Change. 6/1/12 All Replaced entire document with new revision

CATALOG OF REPLACEMENT PARTS

25W Explosion Proof Surface Mount LED Light - C1D1-2 - C2D1-2 - Aluminum Frame V AC

Pacific Gas and Electric Company Energy Efficiency Rebates for Your Business. Lighting Rebate Catalog Saving energy for a brighter future

Electrical Systems Existing Conditions and Building Load Summary Report

50W Explosion Proof Trunnion Mount Compact LED Flood Light - C1D2, C2D1 - Paint Spray Booth Approved

Lighting Depth Part 1: Exterior Space

Vaporproof White LED Light - 10 Watts - Non-Metallic - Corrosion Resistant Lumens

SECTION LIGHTING REGULATIONS

HID lighting for hazardous areas Champ HID floodlighting. Champ floodlights. HID floodlighting for hazardous areas

AERS. Automatic Energy Reduction System HID lamp control systems for maximum energy savings

Hazardous Location LED String Lights - 5 Jelly Jar Lamps - Non Metallic - Chemical Resistant - CID2

300W Low Profile Clean Room LED Light - LED Signal Light - C1D1 - C2D2 - ISO 14644/FS-209E Rated

Petrolux III. PW Series Wet Locations

Lord Stirling Community School Electrical Systems Existing Conditions & Building Load Summary Technical Assingment#2 Due October 26, 2004

What Powered by Design Pro LED Technology means to you!

48W Fluorescent T8 Light w/ Emergency Backup Dimmable Ballast - (2) 2 Foot T8 Lamps - C1D2

HMAO LED. High Mast Series

120W Explosion Proof Signal Light w/ Audible Alarm - C1D1 - (2) Colored LED Lamps - 55 Horn Tones

lumen & ecoluz sustainable lighting by eco:d 1

Fillmore Small Pendant Assembly and Installation Instructions

30-YEAR LIMITED WARRANTY

1 General Description

INDIAN INSTITUTE OF TECHNOLOGY KANPUR

Exterior Security Lighting

Baltimore Gas and Electric Company Electric -- Retail 57. Billing Watts Description Rate

BIRMINGHAM TOWNSHIP CHESTER COUNTY, PENNSYLVANIA Subdivision and Land Development Ordinance No Dated 02/18/03

26 Watt Explosion Proof Low Profile LED Fixture - 3,380 Lumens - Class 1 & 2 Div 1 & 2 - ATEX / IECE

5LCM52XX Series Fan. Owner s Guide and Installation Manual. UL Model NO. : AC-552AL

HOLOPHORMS. PrismGlo

WATLOW IND. WATROD Modular Duct Heater Installation & Maintenance Manual I&M NUMBER: Page: 1 Date:6/11/2008 Rev: 2

CHAPTER 32 EXTERIOR LIGHTING

Union Township Berks County Outdoor Lighting 08/18/03 ORDINANCE NO

Community Sensitive Lighting

ELECTRICAL SUPPLIES NATIONAL REFRIGERATION PRODUCTS WIRE NUTS HEAT SHRINK TUBING CABLE STAPLES CABLE MARKERS

Design Guidelines for Exterior Lighting

NORTH COVENTRY TOWNSHIP SUBDIVISION & LAND DEVELOPMENT ORDINANCE LIGHTING

ROAM DCM Control Specification Guideline Division 16520

Who is Iconic LED? Page 2. Phone:(337)

Lighting Guidelines. Planning Services Department Corporation of the Municipality of Clarington

BRASS. Path & Area Lighting. Introduction. Table of Contents. Dare to Compare

WATLOW ELECTRIC MFG CO. WATROD Duct Heater (module only) I& M Manual I&M NUMBER: Page: 1 Date: 11/25/2013 Rev: 4.00

IMPORTANT SAFETY INSTRUCTIONS:

UPPER DUBLIN TOWNSHIP MONTGOMERY COUNTY, PA STAND-ALONE LIGHTING ORDINANCE

CHAPTER 7 DEVELOPMENT STANDARDS

CEILING FAN OWNER'S MANUAL

HOLOPHANE. Enduratron

Product Catalog. Edition VI. LED Lamp & Fixture

STYLISH SOLUTIONS FOR OUTDOOR AND INDOOR SPACES

A. Connected to the equipment ground B. Bonded to the box C. Connected to nearest water pipe D. Connected to a ground rod

N2MVF Series Compact Fluorescent

Notes. Custom powder coat finished are available.consult factory. To ensure the natural appearance of stainless steel,

Welcome. Page 2. Iconic LED, LLC 1806 W Pinhook Rd. Lafayette, LA Main (337)

DMV Series W For Combustible Dusts

ILB-CP TBTS A MOUNTING DESIGN EMERGENCY LIGHTING EQUIPMENT FOR LED

SUPERNOVA INTERNATIONAL

DLKF. EBARA Submersible Sewage Pumps Specifications Project: Model: Chk d: Date:

Hanson LED C e i l i n g F a n

Transcription:

INTRODUCTION 1. MERCURY VAPOR MV luminaires are for removal only. Maintenance of these fixtures will be for the photocontrol, bulb, or the ballast only. Any other work will constitute replacement with the appropriate High Pressure Sodium (HPS) fixture. 2. HIGH PRESSURE SODIUM HPS fixtures are available in three wattages 70, 200, and 250. The 70W HPS fixture is used almost exclusively for residential roadway lighting. The 200W HPS fixture is used primarily for light to moderately traveled roadways and the 250W HPS fixture for moderate to heavily traveled roadways. Currently, HPS is the most efficient roadway lighting system. 3. METAL HALIDE MH fixtures are available in 400 watt fixtures. These fixtures are used for White Light as roadway lighting and floodlights. 4. CONDUCTOR 12-2 UF without ground is the conductor used to supply voltage to the fixture. All fixtures, besides Series Type, have ballasts that require a 120V supply. Every streetlight bracket shall be grounded for personnel safety. 5. LIGHT SHIELDS Light shields are available, but only for the General Electric fixtures. These shields will reduce the amount of side light projected from the fixture, which may be a nuisance. Light shields must be itemized. 6. R PLATES Lighting plates followed by an R will supply only a fixture, photocontrol, and bulb. Lighting plates LB1, LB2, and LB3 will supply only the bracket, wiring, and mounting hardware. 7. FLOODLIGHTS A. Floodlights are available in 200W HPS, 400W HPS, and 400W MH. They can be mounted as a single fixture on one bracket or two fixtures on a single bracket with the use of an adapter bracket. They all require a 120V supply and are individually controlled by a photocontrol. They are to be installed on the back-side of the pole in the streetlight mounting holes. Plates FL1 and FL2 are to be used when there are NO secondary obstructions. This is the preferred installation because the L bracket is the least expensive. Plates FL3 and FL4 are to be used if there are secondary obstructions on the back-side of the pole such as service drops. The NEMA labels on the front of the fixtures designate the lamp wattage and type. A yellow label designates High Pressure Sodium (HPS), and a red label designates Metal Halide (MH). All floodlight brackets shall be grounded. B. Floodlights are directional fixtures and must be aimed to satisfy the specific lighting requirements. Each fixture has an angle adjustment guide on the side. Generally for most installations, the fixture will be aimed downwards at a 30 to 45 degree angle from the vertical plane. The easiest way to aim the floodlight is to visualize a V. 3. - Page 1 of 18

line extending perpendicular from the front of the fixture. Where this line strikes the ground, or the side of a building, is where the light will be the most intense. Floodlights produce a wedge-shaped light distribution pattern on the ground, as opposed to an elliptical pattern for a roadway fixture. 8. CUTOFF The L9R standard is a HPS cut-off fixture that can be converted to work as a 250W or a 400W fixture. They are for special applications where light pollution is an issue. The plate option issues the correct lamp. The fixture is converted from one wattage to the other by disconnecting the quick-disconnect lead across the fixture capacitor. They come pre-wired as standard for 120V operation, but they can be converted to work at 208, 240, or 277V by changing the tap on the ballast. V. 3. - Page 2 of 18

L1 70 WATT HPS ROADWAY FIXTURE 1 BOL MS 020 2 BOLT, MACHINE, SQUARE HEAD, 5/8X14 2 BKT SL 002 1 BRACKET, STREETLIGHT, 8 FT. LENGTH, 3 FT. RISE, UNIVERSAL BASE 3 CAI UF 001 13 CABLE, UNDERGROUND FEEDER, 12-2 4 COB CO 028 3 CONDUCTOR, COPPER, BARE, #4 5 CNN CP 002 1 CONNECTOR, AL. COMP., SIDE-BY, 6-2 2-1/0 6 CNN CP 008 1 CONNECTOR, AL. COMP., SIDE-BY, 6-2 3/0-4/0 7 CNN VG 003 2 CONNECTOR, VISE GRIP, 6-2 SOL. 10-2 SOL. 8 COV IC 002 1 COVER, INSULATED, D SIZE CONNECTORS/SLEEVES 9 STL LA 004 1 LAMP, 70W HPS 10 STL LU 008 1 LUMINAIRE, 70W, HPS, ROADWAY 11 STL PC 001 1 PHOTOCONTROL, ELECTRONIC, 105V - 135V 12 WAS RD 004 2 WASHER, ROUND, 1-3/4 IN. DIA., FOR 5/8 IN. DIA. BOLT 13 WAS SF 003 2 WASHER, SQUARE, FLAT, 3 IN., FOR 3/4 IN. DIA. BOLT 14 WAS SP 002 2 WASHER, SPRING, DOUBLE HELIX, FOR 3/4 IN. DIA. BOLT V. 3. - Page 3 of 18

L1R 70 WATT HPS ROADWAY FIXTURE WITHOUT BRACKET 1 STL LA 004 1 LAMP, 70W HPS 2 STL LU 008 1 LUMINAIRE, 70W, HPS, ROADWAY 3 STL PC 001 1 PHOTOCONTROL, ELECTRONIC, 105V - 135V V. 3. - Page 4 of 18

L2 200 WATT HPS ROADWAY FIXTURE 1 BOL MS 020 3 BOLT, MACHINE, SQUARE HEAD, 5/8X14 2 BKT SL 007 1 BRACKET, STREETLIGHT, 12 FT. LENGTH, 4 FT. RISE, UNIVERSAL BASE 3 CAI UF 001 18 CABLE, UNDERGROUND FEEDER, 12-2 4 COB CO 028 3 CONDUCTOR, COPPER, BARE, #4 5 CNN CP 002 1 CONNECTOR, AL. COMP., SIDE-BY, 6-2 2-1/0 6 CNN CP 008 1 CONNECTOR, AL. COMP., SIDE-BY, 6-2 3/0-4/0 7 CNN VG 003 2 CONNECTOR, VISE GRIP, 6-2 SOL. 10-2 SOL. 8 COV IC 002 1 COVER, INSULATED, D SIZE CONNECTORS/SLEEVES 9 STL LA 003 1 LAMP, 200W HPS 10 STL LU 007 1 LUMINAIRE, 200W, HPS, ROADWAY 11 STL PC 001 1 PHOTOCONTROL, ELECTRONIC, 105V - 135V 12 WAS RD 004 3 WASHER, ROUND, 1-3/4 IN. DIA., FOR 5/8 IN. DIA. BOLT 13 WAS SF 003 3 WASHER, SQUARE, FLAT, 3 IN., FOR 3/4 IN. DIA. BOLT 14 WAS SP 002 3 WASHER, SPRING, DOUBLE HELIX, FOR 3/4 IN. DIA. BOLT V. 3. - Page 5 of 18

L2R 200 WATT HPS ROADWAY FIXTURE WITHOUT BRACKET 1 STL LA 003 1 LAMP, 200W HPS 2 STL LU 007 1 LUMINAIRE, 200W, HPS, ROADWAY 3 STL PC 001 1 PHOTOCONTROL, ELECTRONIC, 105V - 135V V. 3. - Page 6 of 18

L3 250 WATT HPS ROADWAY FIXTURE 1 BOL MS 020 3 BOLT, MACHINE, SQUARE HEAD, 5/8X14 2 BKT SL 007 1 BRACKET, STREETLIGHT, 12 FT. LENGTH, 4 FT. RISE, UNIVERSAL BASE 3 CAI UF 001 18 CABLE, UNDERGROUND FEEDER, 12-2 4 COB CO 028 3 CONDUCTOR, COPPER, BARE, #4 5 CNN CP 002 1 CONNECTOR, AL. COMP., SIDE-BY, 6-2 2-1/0 6 CNN CP 008 1 CONNECTOR, AL. COMP., SIDE-BY, 6-2 3/0-4/0 7 CNN VG 003 2 CONNECTOR, VISE GRIP, 6-2 SOL. 10-2 SOL. 8 COV IC 002 1 COVER, INSULATED, D SIZE CONNECTORS/SLEEVES 9 STL LA 002 1 LAMP, 250W HPS 10 STL LU 006 1 LUMINAIRE, 250W, HPS, ROADWAY 11 STL PC 001 1 PHOTOCONTROL, ELECTRONIC, 105V - 135V 12 WAS RD 004 3 WASHER, ROUND, 1-3/4 IN. DIA., FOR 5/8 IN. DIA. BOLT 13 WAS SF 003 3 WASHER, SQUARE, FLAT, 3 IN., FOR 3/4 IN. DIA. BOLT 14 WAS SP 002 3 WASHER, SPRING, DOUBLE HELIX, FOR 3/4 IN. DIA. BOLT V. 3. - Page 7 of 18

L3R 250 WATT HPS ROADWAY FIXTURE WITHOUT BRACKET 1 STL LA 002 1 LAMP, 250W HPS 2 STL LU 006 1 LUMINAIRE, 250W, HPS, ROADWAY 3 STL PC 001 1 PHOTOCONTROL, ELECTRONIC, 105V - 135V V. 3. - Page 8 of 18

L8R 400W METAL HALIDE ROADWAY FIXTURE - WITHOUT BRACKET 1 STL LA 008 1 LAMP, 400W METAL HALIDE 2 STL LU 016 1 LUMINAIRE, 400W, METAL HALIDE, ROADWAY, CUT-OFF 3 STL PC 001 1 PHOTOCONTROL, ELECTRONIC, 105V - 135V V. 3. - Page 9 of 18

L9R 250/400 WATT HPS CUT-OFF ROADWAY FIXTURE WITHOUT BRACKET OPTIONS: 250, 400 1 STL LA *** 1 GENERAL CODE FOR HPS LAMP 2 STL LU 015 1 LUMINAIRE, 200/400W, HPS, ROADWAY, CUT-OFF 3 STL PC 001 1 PHOTOCONTROL, ELECTRONIC, 105V - 135V V. 3. - Page 10 of 18

LB1 8 FOOT BRACKET WITHOUT FIXTURE 1 BOL MS 020 2 BOLT, MACHINE, SQUARE HEAD, 5/8X14 2 BKT SL 002 1 BRACKET, STREETLIGHT, 8 FT. LENGTH, 3 FT. RISE, UNIVERSAL BASE 3 CAI UF 001 13 CABLE, UNDERGROUND FEEDER, 12-2 4 COB CO 028 3 CONDUCTOR, COPPER, BARE, #4 5 CNN CP 002 1 CONNECTOR, AL. COMP., SIDE-BY, 6-2 2-1/0 6 CNN CP 008 1 CONNECTOR, AL. COMP., SIDE-BY, 6-2 3/0-4/0 7 CNN VG 003 2 CONNECTOR, VISE GRIP, 6-2 SOL. 10-2 SOL. 8 COV IC 002 1 COVER, INSULATED, D SIZE CONNECTORS/SLEEVES 9 WAS RD 004 2 WASHER, ROUND, 1-3/4 IN. DIA., FOR 5/8 IN. DIA. BOLT 10 WAS SF 003 2 WASHER, SQUARE, FLAT, 3 IN., FOR 3/4 IN. DIA. BOLT 11 WAS SP 002 2 WASHER, SPRING, DOUBLE HELIX, FOR 3/4 IN. DIA. BOLT V. 3. - Page 11 of 18

LB2 12 FOOT BRACKET WITHOUT FIXTURE 1 BOL MS 020 3 BOLT, MACHINE, SQUARE HEAD, 5/8X14 2 BKT SL 007 1 BRACKET, STREETLIGHT, 12 FT. LENGTH, 4 FT. RISE, UNIVERSAL BASE 3 CAI UF 001 18 CABLE, UNDERGROUND FEEDER, 12-2 4 COB CO 028 3 CONDUCTOR, COPPER, BARE, #4 5 CNN CP 002 1 CONNECTOR, AL. COMP., SIDE-BY, 6-2 2-1/0 6 CNN CP 008 1 CONNECTOR, AL. COMP., SIDE-BY, 6-2 3/0-4/0 7 CNN VG 003 2 CONNECTOR, VISE GRIP, 6-2 SOL. 10-2 SOL. 8 COV IC 002 1 COVER, INSULATED, D SIZE CONNECTORS/SLEEVES 9 WAS RD 004 3 WASHER, ROUND, 1-3/4 IN. DIA., FOR 5/8 IN. DIA. BOLT 10 WAS SF 003 3 WASHER, SQUARE, FLAT, 3 IN., FOR 3/4 IN. DIA. BOLT 11 WAS SP 002 3 WASHER, SPRING, DOUBLE HELIX, FOR 3/4 IN. DIA. BOLT V. 3. - Page 12 of 18

LB3 15 FOOT BRACKET - WITHOUT FIXTURE 1 BOL MS 020 3 BOLT, MACHINE, SQUARE HEAD, 5/8X14 2 BKT SL 008 1 BRACKET, STREETLIGHT, 15 FT. LENGTH, 8 FT. RISE, UNIVERSAL BASE 3 CAI UF 001 18 CABLE, UNDERGROUND FEEDER, 12-2 4 COB CO 028 3 CONDUCTOR, COPPER, BARE, #4 5 CNN CP 002 1 CONNECTOR, AL. COMP., SIDE-BY, 6-2 2-1/0 6 CNN CP 008 1 CONNECTOR, AL. COMP., SIDE-BY, 6-2 3/0-4/0 7 CNN VG 003 2 CONNECTOR, VISE GRIP, 6-2 SOL. 10-2 SOL. 8 COV IC 002 1 COVER, INSULATED, D SIZE CONNECTORS/SLEEVES 9 WAS RD 004 3 WASHER, ROUND, 1-3/4 IN. DIA., FOR 5/8 IN. DIA. BOLT 10 WAS SF 003 3 WASHER, SQUARE, FLAT, 3 IN., FOR 3/4 IN. DIA. BOLT 11 WAS SP 002 3 WASHER, SPRING, DOUBLE HELIX, FOR 3/4 IN. DIA. BOLT V. 3. - Page 13 of 18

L13 OBSTRUCTION LIGHT 1 XXX ZZ 075 8 NIPPLE, 1/2 X 1-1/2 2 XXX ZZ 076 1 T CONNECTOR, 1/2 3 XXX ZZ 077 2 ELBOW, 1/2 4 CAI UF 001 30 CABLE, UNDERGROUND FEEDER, 12-2 5 CNN CP 002 2 CONNECTOR, AL. COMP., SIDE-BY, 6-2 2-1/0 6 COD ST 001 30 CONDUIT, STEEL, 1/2 7 LAM IN 001 2 LAMP, INCANDESCENT, 69 WATT, 120V 8 LIG OB 001 1 LIGHT, OBSTRUCTION 9 STL PC 001 1 PHOTOCONTROL, ELECTRONIC, 105V - 135V 10 STL PC 004 1 PHOTOCONTROL BRACKET W/ RECEPTACLE 11 STP ST 002 8 STRAP, CONDUIT, 3/4 V. 3. - Page 14 of 18

FL1 SINGLE MOUNT FLOODLIGHT NO SECONDARY OBSTRUCTIONS 200W HPS, 400W HPS, 400W MH OPTIONS: 2H, 4H, 4M 1 BKT SL 013 1 BRACKET, SINGLE MOUNT, FOR FLOODLIGHT 2 BOL MS 020 2 BOLT, MACHINE, SQUARE HEAD, 5/8X14 3 CNN CP 002 1 CONNECTOR, AL. COMP., SIDE-BY, 6-2 2-1/0 4 CNN CP 008 1 CONNECTOR, AL. COMP., SIDE-BY, 6-2 3/0-4/0 5 CNN VG 002 2 CONNECTOR, VISE GRIP, 8-4 SOL. 12-4 SOL. 6 COB CO 028 3 CONDUCTOR, COPPER, BARE, #4 7 COV IC 002 1 COVER, INSULATED, D SIZE CONNECTORS/SLEEVES 8 STL FL *** 1 GENERAL CODE FOR FLOODLIGHT FIXTURE 9 STL LA *** 1 GENERAL CODE FOR LAMP 10 STL PC 001 1 PHOTOCONTROL, ELECTRONIC, 105V - 135V 11 WAS RD 004 4 WASHER, ROUND, 1-3/4 IN. DIA., FOR 5/8 IN. DIA. BOLT 12 WAS SF 003 2 WASHER, SQUARE, FLAT, 3 IN., FOR 3/4 IN. DIA. BOLT 13 WAS SP 002 2 WASHER, SPRING, DOUBLE HELIX, FOR 3/4 IN. DIA. BOLT V. 3. - Page 15 of 18

FL2 DOUBLE MOUNT FLOODLIGHT NO SECONDARY OBSTRUCTIONS 200W HPS, 400W HPS, 400W MH OPTIONS: 2H, 4H, 4M 1 BKT SL 012 1 BRACKET, FLOODLIGHT ADAPTER 2 BKT SL 013 1 BRACKET, SINGLE MOUNT, FOR FLOODLIGHT 3 BOL MS 020 2 BOLT, MACHINE, SQUARE HEAD, 5/8X14 4 CNN CP 002 2 CONNECTOR, AL. COMP., SIDE-BY, 6-2 2-1/0 5 CNN CP 008 2 CONNECTOR, AL. COMP., SIDE-BY, 6-2 3/0-4/0 6 CNN VG 002 3 CONNECTOR, VISE GRIP, 8-4 SOL. 12-4 SOL. 7 COB CO 028 3 CONDUCTOR, COPPER, BARE, #4 8 COV IC 002 2 COVER, INSULATED, D SIZE CONNECTORS/SLEEVES 9 STL FL *** 2 GENERAL CODE FOR FLOODLIGHT FIXTURE 10 STL LA *** 2 GENERAL CODE FOR LAMP 11 STL PC 001 2 PHOTOCONTROL, ELECTRONIC, 105V - 135V 12 WAS RD 004 4 WASHER, ROUND, 1-3/4 IN. DIA., FOR 5/8 IN. DIA. BOLT 13 WAS SF 003 2 WASHER, SQUARE, FLAT, 3 IN., FOR 3/4 IN. DIA. BOLT 14 WAS SP 002 2 WASHER, SPRING, DOUBLE HELIX, FOR 3/4 IN. DIA. BOLT V. 3. - Page 16 of 18

FL3 SINGLE MOUNT FLOODLIGHT WITH SECONDARY OBSTRUCTIONS 200W HPS, 400W HPS, 400W MH OPTIONS: 2H, 4H, 4M 1 BKT SL 011 1 BRACKET, SINGLE MOUNT, FOR FLOODLIGHT, 4 FOOT LENGTH 2 BOL MS 020 2 BOLT, MACHINE, SQUARE HEAD, 5/8X14 3 CNN CP 002 1 CONNECTOR, AL. COMP., SIDE-BY, 6-2 2-1/0 4 CNN CP 008 1 CONNECTOR, AL. COMP., SIDE-BY, 6-2 3/0-4/0 5 CNN VG 002 2 CONNECTOR, VISE GRIP, 8-4 SOL. 12-4 SOL. 6 COB CO 028 3 CONDUCTOR, COPPER, BARE, #4 7 COV IC 002 1 COVER, INSULATED, D SIZE CONNECTORS/SLEEVES 8 STL FL *** 1 GENERAL CODE FOR FLOODLIGHT FIXTURE 9 STL LA *** 1 GENERAL CODE FOR LAMP 10 STL PC 001 1 PHOTOCONTROL, ELECTRONIC, 105V - 135V 11 WAS RD 004 4 WASHER, ROUND, 1-3/4 IN. DIA., FOR 5/8 IN. DIA. BOLT 12 WAS SF 003 2 WASHER, SQUARE, FLAT, 3 IN., FOR 3/4 IN. DIA. BOLT 13 WAS SP 002 2 WASHER, SPRING, DOUBLE HELIX, FOR 3/4 IN. DIA. BOLT V. 3. - Page 17 of 18

FL4 DOUBLE MOUNT FLOODLIGHT WITH SECONDARY OBSTRUCTIONS 200W HPS, 400W HPS, 400W MH OPTIONS: 2H, 4H, 4M 1 BKT SL 011 1 BRACKET, SINGLE MOUNT, FOR FLOODLIGHT, 4 FOOT LENGTH 2 BKT SL 012 1 BRACKET, FLOODLIGHT ADAPTER 3 BOL MS 020 2 BOLT, MACHINE, SQUARE HEAD, 5/8X14 4 CNN CP 002 2 CONNECTOR, AL. COMP., SIDE-BY, 6-2 2-1/0 5 CNN CP 008 2 CONNECTOR, AL. COMP., SIDE-BY, 6-2 3/0-4/0 6 CNN VG 002 3 CONNECTOR, VISE GRIP, 8-4 SOL. 12-4 SOL. 7 COB CO 028 3 CONDUCTOR, COPPER, BARE, #4 8 COV IC 002 2 COVER, INSULATED, D SIZE CONNECTORS/SLEEVES 9 STL FL *** 2 GENERAL CODE FOR FLOODLIGHT FIXTURE 10 STL LA *** 2 GENERAL CODE FOR LAMP 11 STL PC 001 2 PHOTOCONTROL, ELECTRONIC, 105V - 135V 12 WAS RD 004 4 WASHER, ROUND, 1-3/4 IN. DIA., FOR 5/8 IN. DIA. BOLT 13 WAS SF 003 2 WASHER, SQUARE, FLAT, 3 IN., FOR 3/4 IN. DIA. BOLT 14 WAS SP 002 2 WASHER, SPRING, DOUBLE HELIX, FOR 3/4 IN. DIA. BOLT V. 3. - Page 18 of 18