Operating instructions

Similar documents
Operating instructions

User manual. Logano GC 124 II. Gas boiler

Operating Instructions

Operating instructions

Installation and maintenance instructions

Conversion Instructions Logano G234X. Gas boiler. Please read carefully before installing and servicing. Gas boiler

TO DO IF YOU SMELL GAS

Operating instructions

/2010 US/CA

Ignition Burner Maintenance

USER'S INFORMATION MANUAL

USER'S INFORMATION MANUAL

Residential Gas Condensing Boiler Greenstar combi 100 p / 151 p ZWB28-3A... ZWB42-3A...

USER'S INFORMATION MANUAL

USER S INFORMATION MANUAL

User s Information Manual Models: 45, ,000 Btu/hr

USER'S INFORMATION MANUAL

USER'S INFORMATION MANUAL

USER'S INFORMATION MANUAL

USER'S INFORMATION MANUAL

Cast Iron Commercial Hot Water Or Steam Boiler

O. Gas boiler. Gaz 6000 W WBN H-E-N/L-S2400. Operating instructions for the end customer (2017/09) en

USERS INFORMATION MANUAL FOR GAS FIRED BOILERS

USER'S INFORMATION MANUAL

USER S INFORMATION MANUAL

USER'S INFORMATION MANUAL

Model BW9 Gas-Fired Direct Vent Condensing Water Boiler

USER S INFORMATION MANUAL

USER'S INFORMATION MANUAL

ZG Shown READ ALL INSTRUCTIONS IN THIS MANUAL AND RETAIN FOR FUTURE REFERENCE WARNING

User s Information Manual

User Manual FLOWMAX-90. for model. Condensing water heater 85,000 BTU. Installation, operating, commissioning and maintenance instructions.

Residential Gas Condensing Boiler Greenstar ZBR16/21/28/35/42-3A... ZWB28/35/42-3A...

User s Information Manual

USER S INFORMATION MANUAL

User s Information Manual Galaxy GG/GX Series, Sentry S/SX Series and Sentinel SE Series Gas Boilers with Continuous Burning Pilot

USER S INFORMATION MANUAL (2,4)SG13B

READ ALL INSTRUCTIONS IN THIS MANUAL AND RETAIN FOR FUTURE REFERENCE WARNING

WHAT TO DO IF YOU SMELL GAS

Installation and Service Instructions LoganoUS/CA GC 144 II

DT/DTH/DR/DRH MERIT SERIES

PROBLEM CAUSE SOLUTION

DT-2 & DR-2 MERIT SERIES

User s Information Manual Lynx Direct-Vent Sealed Combustion Condensing Boiler Model LX-90, LX-120, LX-150

Packaged Gas/Electric Units. Owner s Guide to Operating and Maintaining Your Gas/Electric Unit

Bosch 80% AFUE Gas Furnace BGS80 Model

User's Infomation Manual

Good Ideas For Propane Safety

KG 092 SHOWN READ ALL INSTRUCTIONS IN THIS MANUAL AND RETAIN FOR FUTURE REFERENCE WARNING

WARNING FIRE OR EXPLOSION HAZARD.

RETAIN THESE INSTRUCTIONS FOR FUTURE REFERENCE :$51,1*

WARNING FIRE OR EXPLOSION HAZARD.

95M-200 GAS-FIRED DIRECT VENT MODULATING HOT WATER BOILER

P.O. Box , Dallas, TX USER'S INFORMATION MANUAL Single-Stage Warm Air Gas Furnaces

KGA092 SHOWN READ ALL INSTRUCTIONS IN THIS MANUAL AND RETAIN FOR FUTURE REFERENCE WARNING

ML180UH SERIES GAS FURNACE WARNING WARNING

EL195UHE SERIES GAS FURNACE WARNING WARNING

EL296UHV SERIES GAS FURNACE WARNING WARNING

Installation and maintenance instructions

USER S INFORMATION MANUAL

MANUAL WARNING FIRE OR EXPLOSION HAZARD. SL280UHNV SERIES WHAT TO DO IF YOU SMELL GAS:

TGA/KGA024, 030, 036, 048, 060, 072, 090 (2, 2 1/2, 3, 4, 5, 6, and 7 1/2 TONS)

Suburban Propane Notice of Public Awareness. Additional Information for Customer s Buried Piping

USER S INFORMATION MANUAL Model: HSE 125 N/P, HSE 145 N/P Gas-fired, Condensing Boiler and Instantaneous Water Heater

G61MPV SERIES GAS FURNACE WARNING

USER S, MAINTENANCE and SERVICE INFORMATION MANUAL

User s Information Manual Models: ER152, ER202, ER252, ER302, and ER402

USER S INFORMATION MANUAL

User s Information Manual

SERVICE AND INSTALLATION MANUAL MODELS HDO(H) OIL FOR YOUR SAFETY

User s Information Manual

GOLD CGt. User s Information Manual. Natural gas-fired water boiler with tankless heater

Aqua Balance. User s Information Manual. WMB-155C Wall Mount Gas-Fired Combination Boiler Heating and Domestic Hot Water

prestige Control Application Supplement - Type 5 MCBA WARNING

EL195DFE SERIES GAS FURNACE WARNING

Operating instructions Oil condensing boiler

User s Information Manual

User s Information Manual

Fig. 1 - Unit PGD4, PGS4, WPG4

USER'S INFORMATION MANUAL

Model RGAC/SGAC Self Contained Cooling/Gas Heat MODELS RGAC & SGAC - R22 USER'S INFORMATION, MAINTENANCE AND SERVICE MANUAL

FGR. Installation, Operation and Startup Instruction Manual FOR FLUE GAS RECIRCULATION SYSTEM. FGR-8 through FGR-22 (25 HP to 1000 HP)

EL195UH SERIES GAS FURNACE WARNING

USER S, MAINTENANCE and SERVICE INFORMATION MANUAL

USER S INFORMATION MANUAL

User s Information Manual

Users manual. Buderus /29/43/60 and Buderus T25/29T25 H/V. Wall-mounted condensing gas boiler. For the user

Owner s Information Manual

OPERATING INSTRUCTIONS AND OWNER S MANUAL

User s Information Manual

SLP98UH SERIES VARIABLE CAPACITY GAS FURNACE WARNING WARNING

USER'S MANUAL PGE Single Package Rooftop

USER S INFORMATION MANUAL

User s Information Manual

User's Information Manual Customer Property: Contains wiring and service information.

T UNI 7000 F. Operating instructions For the user (2006/05) AU/GB

If the information in this manual is not followed exactly, a fire or explosion may result causing property damage, personal injury or loss of life.

Operating instructions

WHE 2.24 / WHE 2.24 FF

User s Information Manual Models:

Transcription:

6304 0307 04/2005 US For the installer Operating instructions Sealed combustion boiler Logano GA24 SC and atmospheric boiler Logano G24X II/SP If these instructions are not followed exactly, a fire or explosion may be caused with serious property damage or loss of life and serious injury. Do not store or use gasoline or any other flammable vapors or liquids in the vicinity of this system or any other heating system. IF A SMELL OF GAS IS DETECTED: Do not switch on any electrical appliances. Do not operate electrical switches; do not use a telephone in the building. Call gas company immediately from outside the building. Follow these instructions. If you cannot reach your gas company, call the fire department. The heating system must only be installed and serviced by a qualified service company, a qualified service or gas supply company. NOTE! Please keep these instructions for future reference. Please read carefully before use.

For your safety For your safety The Logano GA24 SC and Logano G24X II/SP gas-fired boilers are designed and manufactured in accordance with in state of the art in technology and safety. Particular emphasis is placed on ease of operation. We recommend reading and following the safety instructions and operating manual for safe, economical and environmentally responsible operation of the heating system.. Correct use The Logano GA24 SC and Logano G24X II/SP gasfired boilers are designed to heat water using indirect domestic hot water tanks and space for heating single or multi family buildings..2 Notes structure Additional symbols for identification of dangers and user instructions. CAUTION! RISK TO LIFE Identifies possible dangers emanating from a product, which might lead to serious injury or death if appropriate care is not taken. RISK OF INJURY/ SYSTEM DAMAGE Identifies potentially dangerous situations, which might lead to medium or slight injuries or to property losses. USER NOTE Information on optimum utilization and setting of the control(s) plus other useful information..3 Please observe these safety instructions Improper operation of the boiler may cause property damage. Only use the boiler for the intended purpose and only if it is in perfect working order. Have the heating system installed by a heating contractor. The contractor must give detailed instructions on the operation of the heating system. Please read these operating instructions carefully..3. Boiler room CAUTION! RISK TO LIFE due to neglecting your own safety in case of emergency, such in case of a fire. Never put yourself at risk. Your own safety must always take priority. BOILER DAMAGE AND OPERATING DEFECTS due to missing or inadequate openings for combustion air and venting of the boiler room. Make sure that inlets and outlets are not obstructed or blocked off. If defects are not corrected immediately, the boiler must not be operated. FIRE DANGER due to flammable material or liquids. Do not store flammable material or liquids in the immediate vicinity of the heat generator. CAUTION! SYSTEM DAMAGE through frost. Make sure that the boiler room is protected from freezing. 2 Operating instructions Logano GA24 SC/G24X II/SP special gas-fired boiler Issue 04/2005

For your safety.3.2 Working on the heating system RISK TO LIFE from explosion of flammable gases. Make sure that a qualified company installs the boiler, connects gas, oil and flue connections, places the boiler in operation, connects the electrical power, and maintains and repairs the boiler. Make sure that a licensed contractor carries out all work on gas transmission parts. Additional important system Do not operate if any part is under water. Contact a qualified customer service technician immediately to have the unit checked and to replace the parts of the control and gas fittings that were under water. If the system overheats or the gas supply does not shut off, do not switch off or interrupt the power to the pump. Instead shut off the gas supply at a point outside the heating system. The flue system must be inspected and cleaned once a year. All parts that show any signs of damage by corrosion or other causes must be replaced. The boiler must be serviced by qualified boiler service company once a year. The inspection must include the main burner, ignition burner, fan shroud, combusion air tube, the complete flue system and the venting openings or venting equipment. All parts that show any signs of damage from corrosion or other causes must be replaced. Operating instructions Logano GA24 SC/G24X II/SP special gas-fired boiler Issue 04/2005 3

2 Product description 2 Product description The boilers are low temperature gas-fired boilers. The boilers consist of: Automatic ignition module (GA24 SC/G24X II only) and aquastat Logamatic 207 control (OPTIONAL) Boiler jacket and front panel Boiler block with insulation Burner USER NOTE The boilers are fully functional with the factory-installed aquastats. A Logamatic 207 control can be installed in addition to the factory-installed aquastat. The automatic ignition, the aquastat and, if applicable, the Logamatic 207 monitor and control all electrical components of the boiler. The boiler jacket and invulation prevent energy loss and provide soundproofing. The boiler block transfers the heat generated by the burner to the boiler water. 4 5 Fig. Logano G24X II boiler Boiler front panel 2 Logamatic 207 control (optional) 3 Ignition module 4 Aquastat (control unit) 5 Boiler jacket 6 Boiler block with insulation 7 Burner 2 3 4 5 6 7 2 3 2 3 4 6 5 6 Fig. 3 Logano GA24 boiler Burner 2 Boiler jacket 3 Boiler block with insulation 4 Logamatic 207 control (optional) 5 Aquastat (control unit) 6 Boiler front panel Fig. 2 Logano G24X SP boiler Boiler front panel 2 Logamatic 207 control (optional) 3 Aquastat 4 Boiler jacket 5 Boiler block with insulation 6 Burner 4 Operating instructions Logano GA24 SC/G24X II/SP special gas-fired boiler Issue 04/2005

Start-up instructions 3 3 Start-up instructions For your own safety read the instructions before start-up. RISK TO LIFE due to not observing the start-up instructions and resulting incorrect operation. If these instructions are not followed exactly, a fire or explosion may be caused with serious property damage or loss of life or serious injury. Observe the start-up instructions. DANGER OF EXPLOSION If you smell gas, there is a danger of explosion. No open flame. No smoking. Prevent spark generation. Do not operate electrical switches, telephones, plugs or door bells. Close main gas valve. Open doors and windows. Warn other occupants of the building. Evacuate the building. Call gas company, heating service company or fire department from outside the building. A B C D For GA24 SC and G24X II This unit is with an ignition system that automatically starts the burner. Do not attempt to ignite it manually. G24X SP only: This unit is equipped with a burner that must be ignited manually. Follow the instructions below to ignite the burner. Check for an odor of gas around the heating system. This test must also be conducted at floor level, because some types of gas are heavier than air and may accumulate at floor level. Switch on the ON/OFF switch on the gas valve by hand only. Never use a tool as assistance. If you cannot actuate the ON/OFF switch on the gas valve by hand, do not attempt to repair it. Contact a qualified technician. Any attempt to use force or to repair the switch may cause a fire or explosion. Do not operate the unit if any part is under water. Contact a qualified customer service technician immediately to have the unit checked and to replace the parts of the control and gas valve that were under water. Operating instructions Logano GA24 SC/G24X II/SP special gas-fired boiler Issue 04/2005 5

3 Start-up instructions 3. Operating instructions for GA24 SC and G24X II STOP! First read the safety instructions on page 5 of these instructions.. Set thermostat to the lowest value. 2. Disconnect the heating system from the power supply. 3. Shut off main gas supply valve. 4. Remove screws from the left and right side panels, then lift the front panel off the boiler and pull it forward. 5. Turn gas valve ON/OFF button clockwise to OFF position. Do not use force. 6. Wait five (5) minutes until all gas residues have dissipated. Check whether there is still any smell of gas, including at floor level. If there is a gas odor: STOP! Follow instructions in section "B" of the safety instructions in ( Chapter 3, page 5). If there is no sign of a gas odor, continue with the next step. USER NOTE This unit is fitted with an ignition system that automatically starts the pilot burner. Do not attempt to ignite it manually. Fig. 4 Removing front panel of boiler (G24X II) 7. Turn gas valve ON/OFF switch counterclockwise to ON position. Do not use force. 8. Attach front panel of boiler ( Fig. 4). 9. Open main gas supply shut-off. 0. Switch on electric power to heating system.. Set thermostat to desired room temperature. 2. If the heating system does not start operating, follow the instructions for "switching off gas supply to boiler" ( Chapter 3.3, page 0) and inform your service technician or your gas supply company. Fig. 5 Gas valve ON/OFF button on gas valve 6 Operating instructions Logano GA24 SC/G24X II/SP special gas-fired boiler Issue 04/2005

Start-up instructions 3 3.2 Operating instructions for G24X SP: STOP! First read the safety instructions on page 5 of these instructions.. Set thermostat to the lowest value. 2. Disconnect the heating system from the power supply. 3. Shut off main gas supply shut-off. 4. Remove screws from the left and right side panels, then lift the front panel off the boiler and pull it forward. 5. Turn gas valve ON/OFF button clockwise to OFF position. Do not use force. 6. Wait five (5) minutes until all gas residues have dissipated. Check whether there is still any smell of gas, including at floor level. If there is a gas odor: STOP! Follow instructions in section "B" of the safety instructions in ( Chapter 3, page 5). If there is no sign of a gas odor, continue with the next step. Fig. 6 Removing front panel of boiler USER NOTE This unit is equipped with an pilot burner that must be ignited manually. Follow the instructions below to ignite the burner. Fig. 7 G24X SP gas valve ON/OFF button (at ON position) Operating instructions Logano GA24 SC/G24X II/SP special gas-fired boiler Issue 04/2005 7

3 Start-up instructions 7. Look at the igniter through the viewing glass in the burner housing. 8. Turn gas valve ON/OFF switch counterclockwise to PILOT position. 9. Press reset button in all the way and hold. 0. Ignite the pilot burner with the supplied match holder and a burning match through the viewing glass in the burner housing.. When the pilot burner is burning, continue to hold the red reset button for about a minute. 2. Release red reset button. The red reset button must pop up and the pilot burner must continue burning. If the pilot burner goes out, turn gas fitting ON/OFF button clockwise to OFF position. Fig. 8 G24X SP boiler Viewing glass 3 2 RISK TO LIFE due to poisoning by leaking gas. If the red reset button does not pop up when you release it, STOP. Close main gas shut-off immediately to prevent gas from leaking. Contact your service technician or gas supplier immediately and have the fault repaired. If the pilot burner continues to go out after several attempts, turn the ON/OFF button on the gas valve to OFF immediately to prevent gas from leaking. Fig. 9 G24X SP gas valve ON/OFF button (at ON position) 2 "PILOT" position 3 Reset button 8 Operating instructions Logano GA24 SC/G24X II/SP special gas-fired boiler Issue 04/2005

Start-up instructions 3 3. Turn gas valve ON/OFF switch ( Fig. 9 page 8) counterclockwise to ON position. The gas valve ON/OFF switch can only be set to ON if the red reset button is out. 4. Attach front panel of boiler ( Fig. 6 page 7). 5. Open main gas supply shut-off. 6. Switch on electric power to heating system. 7. Set thermostat to desired room temperature. 8. If the heating system does not start operating, follow the instructions for "switching off gas supply to boiler" ( Chapter 3.3, page 0) and inform your customer service technician or your gas company. Operating instructions Logano GA24 SC/G24X II/SP special gas-fired boiler Issue 04/2005 9

3 Start-up instructions 3.3 Shutting off gas supply to boiler. Set thermostat to the lowest value. 2. Disconnect heating system from the power supply before carrying out maintenance work. 3. Remove front panel of boiler 4. Turn gas valve ON/OFF button clockwise to OFF position. Do not use force. 5. If necessary, shut off main gas supply shut-off. 6. Replace front panel of boiler. Fig. 0 Remove front panel of boiler Flame roll-out switch The boiler is equipped with a flame roll-out switch. If the flue duct in the boiler is blocked, the flame roll-out switch responds. Do not try to switch on the boiler. Inform a qualified service company. The flue duct in the boiler must be checked for blockage and the flame roll-out switch replaced. The flame roll-out switch is for one-time use only, and cannot be reused. Fig. Gas valve (GA24 SC/G24X II left, G24X SP right) ON/OFF button (at ON position) 0 Operating instructions Logano GA24 SC/G24X II/SP special gas-fired boiler Issue 04/2005

Shutting down of the boiler 4 4 Shutting down of the boiler 4. Normal boiler shut-down. With the aquastats: Switch off ON/OFF switch ("OFF" position). This shuts down the boiler with all components (e.g. burner). 2. Additional shut-down procedure follow the directions for the aquastat. 3. Logamatic 207 control (accessory): Switch off ON/OFF switch on control ("0" position). This shuts down the boiler with all components (e.g. burner). Fig. 2 Shutting down heating system (with aquastat) ON/OFF switch (main switch) I 0 4. Shut off main fuel supply valve. CAUTION! SYSTEM DAMAGE through frost. The heating system can freeze up in cold weather if it is shut down. Leave the heating system switched ON constantly as much as possible. Protect the heating system from freezing by draining the heater and water pipes at the lowest point. Fig. 3 Shutting down heating system (with Logamatic 207 control) ON/OFF switch 4.2 Emergency shut-down Inform your customer of the procedure in case of emergency, such as a fire.. Never put yourself at risk. Your own safety must always take priority. 2. Shut off main fuel supply valve. 3. Shut down the heating system with the heater emergency switch or the corresponding circuitbreaker. Operating instructions Logano GA24 SC/G24X II/SP special gas-fired boiler Issue 04/2005

BBT North America Corporation 50 Wentworth Avenue Londonderry, NH 03053 Tel. 603-552-00 Fax 603-584-68 www.buderus.net Products manufactured by BBT Thermotechnik GmbH D-35573 Wetzlar www.buderus.de BBT North America Corporation reserves the right to make changes without notice due to continuing engineering and technological advances.