User manual. Logano GC 124 II. Gas boiler

Similar documents
Operating instructions

Operating instructions

Conversion Instructions Logano G234X. Gas boiler. Please read carefully before installing and servicing. Gas boiler

Operating Instructions

Operating instructions

USER'S INFORMATION MANUAL

USER'S INFORMATION MANUAL

USER'S INFORMATION MANUAL

USER'S INFORMATION MANUAL

USER'S INFORMATION MANUAL

USER'S INFORMATION MANUAL

USER'S INFORMATION MANUAL

Cast Iron Commercial Hot Water Or Steam Boiler

USER'S INFORMATION MANUAL

USER'S INFORMATION MANUAL

/2010 US/CA

Connecting cable. Installation instructions (2018/04) US

Ignition Burner Maintenance

TO DO IF YOU SMELL GAS

Residential Gas Condensing Boiler Greenstar ZBR16/21/28/35/42-3A... ZWB28/35/42-3A...

ZG Shown READ ALL INSTRUCTIONS IN THIS MANUAL AND RETAIN FOR FUTURE REFERENCE WARNING

User s Information Manual Models: 45, ,000 Btu/hr

USER'S INFORMATION MANUAL

User s Information Manual

USER S INFORMATION MANUAL

Model BW9 Gas-Fired Direct Vent Condensing Water Boiler

O. Gas boiler. Gaz 6000 W WBN H-E-N/L-S2400. Operating instructions for the end customer (2017/09) en

USER S INFORMATION MANUAL

Residential Gas Condensing Boiler Greenstar combi 100 p / 151 p ZWB28-3A... ZWB42-3A...

Installation and Service Instructions LoganoUS/CA GC 144 II

USER S INFORMATION MANUAL

USERS INFORMATION MANUAL FOR GAS FIRED BOILERS

95M-200 GAS-FIRED DIRECT VENT MODULATING HOT WATER BOILER

USER S INFORMATION MANUAL

User Manual FLOWMAX-90. for model. Condensing water heater 85,000 BTU. Installation, operating, commissioning and maintenance instructions.

Side by side. Cascade Venting System for RTG 199HE. Extension Set for units 3 or Installation instructions

Bosch 80% AFUE Gas Furnace BGS80 Model

Operating instructions

Packaged Gas/Electric Units. Owner s Guide to Operating and Maintaining Your Gas/Electric Unit

READ ALL INSTRUCTIONS IN THIS MANUAL AND RETAIN FOR FUTURE REFERENCE WARNING

Back to back. Cascade Venting System for RTG 199HE. Basic Set for units 1 and Installation instructions

User s Information Manual Models: ER152, ER202, ER252, ER302, and ER402

KG 092 SHOWN READ ALL INSTRUCTIONS IN THIS MANUAL AND RETAIN FOR FUTURE REFERENCE WARNING

Installation and maintenance instructions

USER S, MAINTENANCE and SERVICE INFORMATION MANUAL

KGA092 SHOWN READ ALL INSTRUCTIONS IN THIS MANUAL AND RETAIN FOR FUTURE REFERENCE WARNING

User s Information Manual Lynx Direct-Vent Sealed Combustion Condensing Boiler Model LX-90, LX-120, LX-150

User s Information Manual

TGA/KGA024, 030, 036, 048, 060, 072, 090 (2, 2 1/2, 3, 4, 5, 6, and 7 1/2 TONS)

User s Information Manual

Good Ideas For Propane Safety

User s Information Manual Galaxy GG/GX Series, Sentry S/SX Series and Sentinel SE Series Gas Boilers with Continuous Burning Pilot

User's Infomation Manual

USER S, MAINTENANCE and SERVICE INFORMATION MANUAL

USER S INFORMATION MANUAL

RETAIN THESE INSTRUCTIONS FOR FUTURE REFERENCE :$51,1*

USER S INFORMATION MANUAL (2,4)SG13B

User s Information Manual

DT/DTH/DR/DRH MERIT SERIES

USER'S MANUAL PGE Single Package Rooftop

MC Series Gas-Fired Heating Appliance

WHAT TO DO IF YOU SMELL GAS

Outdoor kit. Models: RTG 199HE / RTG 199ME. Installation Instructions

User s Information Manual

Elite. User s Information Manual. Elite and Elite VWH* All Models

GAS COOKTOP INSTALLATION INSTRUCTIONS BEFORE YOU BEGIN. IMPORTANT Save these instructions for local electrical inspector s use.

User s Information Manual

User s Information Manual

Universal Fire Tube Boiler Wall Mount Models

User s Information Manual

User s Information Manual

GOLD CGt. User s Information Manual. Natural gas-fired water boiler with tankless heater

User s Information Manual Models:

USER'S INFORMATION MANUAL

DT-2 & DR-2 MERIT SERIES

OWNER S MANUAL HIGH EFFICIENCY VARIABLE SPEED GAS-FIRED FURNACES

G61MPV SERIES GAS FURNACE WARNING

Service Instructions. Logamax plus GB kw/100 kw. Condensing gas boiler. For the contractor

WHAT TO DO IF YOU SMELL GAS

P.O. Box , Dallas, TX USER'S INFORMATION MANUAL Single-Stage Warm Air Gas Furnaces

Fig. 1 - Unit PGD4, PGS4, WPG4

Tankless Water Heater

USER S INFORMATION MANUAL

If the information in this manual is not followed exactly, a fire or explosion may result causing property damage, personal injury or loss of life.

Suburban Propane Notice of Public Awareness. Additional Information for Customer s Buried Piping

User's Information Manual Customer Property: Contains wiring and service information.

GB162 Concentric Horizontal Vent Kit

User s Information Manual

HWX GAS BOILERS USER S INFORMATION MANUAL

User s Information Manual

If the information in this manual is not followed exactly, a fire or explosion may result causing property damage, personal injury or loss of life.

User s Information Manual

Marquis User s Manual

Owner s Information Manual

USER S INFORMATION MANUAL

USER S INFORMATION MANUAL Model: HSE 125 N/P, HSE 145 N/P Gas-fired, Condensing Boiler and Instantaneous Water Heater

INSTALLATION GUIDE Dual Fuel Ranges

SUPER HIGH EFFICIENCY WATER HEATERS SUPPLEMENT TO INSTRUCTION MANUAL P/N (Replaces pg. 2 in instruction manual.) CONGRATULATIONS!

User s Information Manual

T UNI 7000 F. Operating instructions For the user (2006/05) AU/GB

Transcription:

User manual Gas boiler WARNING! If the information in this manual is not followed exactly, a fire or explosion may result causing property damage, personal injury or loss of life. B Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance. WHAT TO DO IF YOU SMELL GAS! B Do not try to light any appliance. B Do not touch any electrical switch; do not use any phone in your building. B Immediately call your gas supplier from a neighbor s phone. Follow the gas supplier s instructions. B If you cannot reach your gas supplier, call the Fire Department. B Installation and service must be performed by a qualified installer, service agency or gas supplier. NOTICE: This manual must be retained for future reference. In the Commonwealth of Massachusetts this boiler must be installed by a licensed plumber or gas fitter. Logano GC 124 II 6 720 804 441 (2012/09) EN-US C

Contents Contents 1 Safety considerations................................. 2 1.1 Key to symbols................................. 2 1.2 Safety instructions.............................. 2 2 Product Information................................... 3 2.1 Correct use.................................... 3 2.2 Product description............................. 3 3 Start-up instructions.................................. 3 3.1 Operating instructions........................... 3 3.2 Shutting off gas supply to boiler................... 4 4 Taking the heating system out of operation............... 5 4.1 Normal system shut-down........................ 5 4.2 Emergency shut-down procedures................. 5 1 Safety considerations 1.1 Key to symbols Warnings Warnings in this document are identified by a warning triangle printed against a grey background. Keywords at the start of a warning indicate the type and seriousness of the ensuing risk if measures to prevent the risk are not taken. The following keywords are defined and can be used in this document: NOTE indicates a situation that could result in damage to property or equipment. CAUTION indicates a situation that could result in minor to medium personal injury. WARNING indicates a situation that could result in severe personal injury or death. DANGER indicates a situation that will result in severe injury or death. Important information This symbol indicates important information where there is no risk of personal injury or property damage. Additional symbols Symbol Explanation B Step in an action sequence Cross-reference to another part of the document List entry List entry (second level) Table 1 1.2 Safety instructions Risk of fatal injury from explosion of flammable gases B If you smell gas there is a danger of explosion. B No open flame! No smoking. B Prevent spark formation. Do not operate electrical switches, including telephones, plugs or door bells. B Close main gas valve. B Open doors and windows. B Warn other occupants of the building, but do not use door bells. B Leave the building. B Call gas company and fire department from outside the building. B Make sure that a qualified company installs the boiler, connects gas and venting connections, places the boiler in operation, connects the electrical power, and maintains and repairs the boiler. Risk of fatal injury from neglecting your own safety in case of emergency, such as with a fire B Never put yourself at risk. Your own safety must always take priority. Risk of fatal injury from flue gas poisoning B Make sure that inlets and outlets are not reduced in size or closed. B If faults are not corrected immediately, the boiler must not be operated until all faults have been corrected. 2 GC 124 II 6 720 804 441 (2012/09)

Product Information 2 Risk to life due to water damage B Do not use the boiler if any part has been submerged in water. B Contact a qualified service technician to check and replace any components submerged in water. Fire danger due to flammable materials or liquids B Make sure that there are no flammable materials or liquids in the immediate vicinity of the boiler. B Maintain a minimum distance of 15 inches from the boiler. System damage B Make sure the boiler room stays above freezing. B Do not operate the boiler if damage is present. B Have the heating system installed by a qualified installer, service agency or gas supplier. B Have the installer explain the operation of the heating system. B Read this user manual thoroughly. Other important information! B Should overheating occur or the gas supply fail to shut off, do not turn off or disconnect the electrical supply to the pump. Instead shut off the gas supply at a location external to the boiler. B The venting system must be inspected yearly. Replace any parts that show signs of deterioration from corrosion or any other sources. B The boiler must be inspected yearly by a qualified service agency. The inspection must include the main burners, pilot burner, boiler flue, vent collector and venting system. Replace any parts that show signs of deformation from corrosion or other sources. 6 Fig. 1 Logano GC124 II [1] Boiler front door [2] Boiler temperature control [3] Ignition module [4] Boiler block with insulation [5] Gas burner [6] Boiler jacket 1 2 3 4 5 6 720 804 441-01.1T 2 Product Information 2.1 Correct use The Logano GC124 II atmospheric gas boiler is designed to heat water for a hot water heating system and for heating single or multi-family buildings. 2.2 Product description The GC124 II model boiler is a low temperature atmospheric gas-fired boiler. The boiler consists of: Ignition module and boiler temperature controller Boiler jacket and front door Boiler block with insulation Gas burner The ignition module and boiler temperature controller monitor and control all electrical components of the boiler. The boiler jacket prevents energy loss and acts as soundproofing. The boiler block transfers the heat generated by the burner to the boiler water. The insulation prevents energy loss. 3 Start-up instructions Read the instructions and warnings on page 2 before start-up for your safety. WARNING: Risk to life due to not observing the start-up instructions and resulting incorrect operation. B If these instructions are not followed exactly, a fire or explosion may be caused with serious property damage or loss of life or serious injury. B Observe the start-up instructions. This boiler is equipped with an electronic ignition system which automatically will light the pilot burner. Do not try to manually light the pilot burner. 3.1 Operating instructions STOP! First read the safety instructions on page 2 and the start-up warnings on this page of these instructions. B Set thermostat to the lowest value. B Disconnect the heating system from the power supply. B Shut off main gas supply. B Open the boiler front door. GC 124 II 6 720 804 441 (2012/09) 3

3 Start-up instructions WARNING: Risk to life due to fire or explosion. B Never use excessive force, when adjusting the gas control knob ( figure 3). B Adjust the gas control knob only by hand. B Never use a tool for adjusting the gas control knob. B If you can not turn the gas control knob by hand, do NOT try to repair it. B Contact a qualified service organization at this point. WARNING: Risk of life due to ignition of flammable gases. B Wait 5 (five) minutes until all gas odors have disappeared. Check to see if any gas odors remain, also at floor level. In case gas odors are still present, shut off gas supply, shut off electrical power to the boiler and inform the boiler technician or local gas utility company. B If you do not smell gas, proceed to the next step. This unit is equipped with an automatic ignition system which automatically starts the pilot burner. Do not attempt to ignite it manually. B Turn gas control knob counterclockwise to ON position. Do not use force. B Close boiler front door. B Open main gas supply. B Turn on electric power to heating system. B Set thermostat to desired room temperature. B If the heating system does not start operating, follow the instructions for turning off gas supply to boiler ( chapter 3.2) and inform your boiler technician or your gas company. 6 720 804 441-02.1T Fig. 2 Open boiler front door B Turn the gas control knob clockwise in the "OFF" position. Do not use excessive force. 3.2 Shutting off gas supply to boiler B Set thermostat (optional) to the lowest value. B Disconnect heating system from the power supply by shutting off the emergency shut-off switch outside the boiler room or by disengaging the heating system circuit breaker. B Open boiler front door ( figure 2). B Turn gas control knob clockwise to the OFF position. Do not use excessive force. 1 1 Fig. 3 Gas valve [1] Gas control knob (shown in the "ON" position) 6 720 804 441-03.1T 6 720 804 441-09.1T Fig. 4 Gas valve [1] Gas control knob (shown in the "ON" position) B If necessary, shut off main gas supply. B Close boiler front door. Flame roll-out switch The boiler is equipped with a flame roll-out switch. If the venting system of the boiler is blocked, the flame roll-out switch will respond. Do not try to turn on the boiler. Inform a qualified service company. The venting system of the boiler must be checked for blockage and the flame roll-out switch must be replaced. The flame roll-out switch is for one-time use only. Do not try to reuse it. 4 GC 124 II 6 720 804 441 (2012/09)

Taking the heating system out of operation 4 4 Taking the heating system out of operation 4.1 Normal system shut-down B Turn ON/OFF switch (emergency shutoff switch) to OFF position. This shuts off power to the boiler and all of its components (e.g. burner, aquastat). B Close gas shut off-valve. NOTICE: System damage due to freezing. The heating system can freeze up in cold weather if it is shut down. B Leave the heating system switched ON constantly as much as possible. B Protect the heating system from freezing by draining the boiler and water pipes at the lowest point. 1 6 720 804 441-10.1T Fig. 5 System shut-down [1] ON/OFF switch (emergency shut off switch) 4.2 Emergency shut-down procedures Perform this procedure in case of emergency: B Never put yourself at risk. Your own safety must always take priority. B Shut off main gas supply. B Shut down the heating system using the boiler emergency shutoff switch or the corresponding circuit-breaker. GC 124 II 6 720 804 441 (2012/09) 5

4 Notes 6 GC 124 II 6 720 804 441 (2012/09)

4 Notes GC 124 II 6 720 804 441 (2012/09) 7