Key-Operated Switch GMA 41 / GMA 44 SW. Operation Manual

Similar documents
GMA4100-DP. Control Panel. Operation Manual. Worldwide Supplier of Gas Detection Solutions

GMA 301. Operation Manual. Worldwide Supplier of Safety Solutions. Part Number

Operations Manual GMA 313 CO 2. Gas Monitor for one detection point

Transmitter for O 2 ZD21. Operation Manual

Stand Alone DYNAGARD SP Operation Manual

GMA 41. Operation Manual. Worldwide Supplier of Gas Detection Solutions

Operations Manual TS400. Test Station for G450/G460 Gas Detector

Engineering Guideline. pac- Carriers Type Universal

GMA44 Operation Manual

Micro III (Models G203, G203S, and G213) Operation Manual

EC24. Operation Manual. (Type MWG 2411, MWG 2412, MWG 2413 and MWG 2414)

Engineering Guideline. pac-carriers Type for Yokogawa ProSafe-RS

LINETRAXX VME420. Multi-functional relay for overvoltage, undervoltage and frequency monitoring in AC/DC systems with external supply voltage

Operations Manual TS400. Test Station for G450/G460 Gas Detector

Engineering Guideline. pac-carriers Type SIEMENS ET-200M Fail-safe signal modules

Operations Manual DS 220. Docking Station for Micro IV

Dipl.-Ing. W. Bender GmbH & Co. KG Londorfer Str Grünberg Tel.: Fax:

LINETRAXX RCMA420. Residual current monitor for monitoring AC, DC and pulsed DC currents in TN and TT systems

GMA41. Operation Manual. Controller for mounting on DIN rail

Multi-Gas-Controller MGC2

GMA 104 Operation Manual

GMA200-MT. Operation Manual. Gas detection controller for mounting rail assembly

TS400. Operating Manual. Test Station for Microtector II Series (G450/G460)

Monitoring Devices 11/1

QA16 Addressable System

RAM 50 Series Operation Manual

LINETRAXX VMD420. Multi-functional voltage relay for 3(N)AC systems, frequency/overvoltage/undervoltage, phase, phase failure, asymmetry

MVP-D-TEK Vehicle Loop Detector 9 Volts DC to 240 Volts AC. Operating Instructions

Engineering Guideline. pac-carriers Type for TRICON system TRICONEX TMR PLC

Products and performance

ISOMETER IR425. Insulation monitoring device for unearthed AC/DC control circuits (IT systems)

1.7. Insulation fault evaluators EDS460/490 EDS461/491

1.7. Insulation fault evaluators EDS460/490 EDS461/491

ISOMETER IR425. Insulation monitoring device for unearthed AC/DC control circuits (IT systems)

LC3000 Level Controller Installation and Maintenance Instructions

PolyGard 2-channel Gas Controller MGC-03

GMA200-MW16. Operation Manual. Gas detection controller for wall mounting

GMA 83. Operation Manual. Controller for wall mounting

MICRO III (G202 / G202s / G212) Single Gas Detector

1 measurement signal input 4-20 ma for connection to an external gas sensor 5 freely programmable alarm switching points per measuring point

Operating Manual MSF220V(VU)

Danfoss gas detection units

Instructions for the fan motor control system, SILVER C

Interface and EOL Modules 8

Instructions for the fan motor control system with integrated wiring terminals SILVER C

02/11/2015

Operating Manual MS220KA and MSR220KA

M-Sens 2. Online-Moisture Meter for Solids. Operating Instructions. SWR engineering Messtechnik GmbH

Refrigeration and Air Conditioning Technical leaflet. Electronic controller EKC 201 and EKC 301

INSTRUCTION MANUAL T119 1MN0110 REV. 0. operates with ISO9001 certified quality system

MSM - Expansion modules

THERMAL BUILDING SOLUTIONS EN-TraceTekTTSIM1A-IM-H /16

BT1 SINGLE ZONE FIRE ALARM SYSTEM OPERATORS MANUAL

Installation / Monitoring Technique

GMA200-MW4. User Manual. Gas detection controller for wall mounting

DOCUMENTATION IPS640

DOCUMENTATION IPS640

Operating Instructions

ACTIV8 ONE OFF. 1 Tips USER S GUIDE COMBINED RADAR OPENING AND ACTIVE INFRARED SAFETY SENSOR. 1 Description. 2 Symbols.

PolyGard Single Point Controller SPC-X3-20XX for refrigerant gases and vapours

Wind Alarm Instrument

GS100M Gas Detector. Technical Specification

TTSIM-2 TRACETEK SENSOR INTERFACE MODULE WITH LCD AND RELAY INSTALLATION/OPERATION INSTRUCTIONS

GM420. Digital Ground Continuity Relay For AC Systems. Technical Bulletin NAE /

Operating Instructions

Operating Manual MS220DA

D-TEK -MS Vehicle Loop Detector. Operating Instructions

Quickheat 30 weather compensated boiler control

BU: EPBP GPG: DIN Rail Products Devices for the permanent control of insulation on 24 V supply lines for medical locations SELVTESTER-24

Insulation fault evaluator EDS460-DG

20 Light Remote Annunciator

Wind Alarm Instrument x.x0x

Universal Dimmer N 528D01, 2 x 300VA, AC 230 V 5WG DB01

Table of Contents. 1. Mounting Tips... 2

RFID Card Access Control Unit. Operating Instructions

Assembly. Connection overflow sensor. Connection fat level sensor OFF ON

PolyGard Single Point Controller SPC-X3-11XX for Toxic Gases and Oxygen

Room air quality sensors

Temperature-Relay TR210

GMA 36 Pro. Operation Manual. Stand Alone Monitor

GMA 36 Pro. Operation Manual. Stand Alone Monitor

LC2200 Level Controller Installation and Maintenance Instructions

Room Air Quality Sensors

ISIS SAFETY SYSTEM Installation guide

MODEL ZAC ZONE ANNUNCIATOR/CONTROLLER DESIGNED FOR ZONE ANNUNCIATION AND MONITORING

RAM3 Remote Alarm Module

DEB71. Earth Leakage Monitoring Relay. Benefits. Description

Danfoss gas detection units

CMD420 / CMD421 Series

GMA81 / GMA81A. Operation Manual. Controller for wall mounting

Installation Instructions for Honeywell ALL-SPEC Air Sampling Smoke Detection System

DIGITAL ALARM UNIT Model ALU-AP

1.7 A-ISOMETER IRDH575. RoHS. Dipl.-Ing. W. Bender GmbH & Co. KG Londorfer Str Grünberg Tel.: Fax:

REGARD. REGARD 4-20 AND Ex CHANNEL CARDS INSTALLATION AND OPERATING MANUAL (FOR ATEX VERSION CARDS)

Retroreflective sensor with polarization filter

Operating Instructions

Entwicklung + Fertigung + Service: Heerweg 15 D, Denkendorf Tel.: / Fax.: /

BS-316. Gas detection control panel up to 16 inputs. Installation operation manual

ISOMETER IR1575. Insulation monitoring device for unearthed AC/3(N)AC systems up to 480 V and DC systems up to 480 V

Operating Manual RCM420

Transcription:

Key-Operated witch GMA 41 / GMA 44 W Operation Manual

Table of contents Page Introduction... 4 Key function... 4 Distinction of GMA 41/44 W models... 4 Relays... 5 P.C. boards of GMA 41/44 W... 7 Terminal Diagram GMA 41/44 W... 8 Trouble shooting... 9 Technical data... 9 3

Introduction The key-operated switch GMA 41/44 W serves as collective alarm for gas monitors, which consists of any quantity of GMA 41 B, GMA 41 ECB, GMA 44 B, or GMA 44 ECB. The gas monitors and the key-operated switch have to be connected by means of the bus system. Plug the key in to activate the key-operated switch. Now any new alarm to connected alarm devices or signal lines is suppressed. This may be useful for service and maintenance. Key function The key-operated switch provides 5 voltage-free relay contacts. These relays can be used to control external buzzers, lamps, or telephone lines in case of alarm or system fault. When the key is plugged in, the alarm-stop relay is activated and the stop LED flashes. In the standard configuration (non-deleting alarms), already reported alarms remain valid. New alarm signals, however, will be suppressed and the alarm relays (relays 1, 2, and 3) will not be activated in case of a new alarm. The GMA will not give a warning. This is particularly important during service and maintenance, e.g. when the sensitivity calibration of the connected transmitters is to be checked. The alternative configuration (deleting alarms) allows to de-activate even an already reported alarm. Alarm-stop LED Key lock Pin connector bus system LEDs (red) for alarm 1, 2, and 3 LED (green) for operation LED (yellow) for fault Distinction of GMA 41/44 W models Key-operated switch Model Alarms Built-in 230V mains unit upply voltage uitable for GMA 41 and 44 models GMA 41/44 W 24V tandard Non-deleting No 24V DC 41 B 44 B GMA 41/44 W 24V Alternative Deleting No 24V DC 41 B 44 B GMA 41/44 W 230V tandard Non-deleting Yes 230V AC 41 ECB 44 ECB GMA 41/44 W 230V Alternative Deleting Yes 230V AC 41 ECB 44 ECB The voltage supply of the key-operated switch GMA 41/44 W 24V is specially designed for the operation with several GMA 41 ECB and 44 ECB. 4

Relays The key-operated switch GMA 41/44 W provides 5 relays: 3 alarm relays for controlling external alarm devices 1 fault relay for failure report 1 alarm-stop relay as a signal, that the key-operated switch is activated and new alarms are suppressed Alarm report - alarm 1, alarm 2, and alarm 3 The relays are activated, if the relevant alarm threshold at one of the connected gas monitors is exceeded. Alarm reset is done at the relevant gas monitor. The red LED "ALARM" is lit, if the alarm relay is activated. For the switching behavior of the alarm relays after plugging the electronic key in please refer to the scheme below. Fault The relay is activated, if the key-operated switch is faulty. The relay is activated, if one of the connected gas monitors is faulty. Alarm-stop The relay is activated, if the key is plugged in. Depending on the configuration, already existing alarms will be reset or remain valid. New alarm signals will be suppressed. The LED "TOP" flashes, when the alarm-stop relay is activated. The "ALARM-TOP" relay can be used e.g. to activate a warning panel reading "system out of order". The switching behavior of the relays is the same as for alarm or fault signals. Every relay can be operated as NC or NO contact in closed or open circuit systems. For the switching functions as NC and NO relays you will find contact clamps. The relay operation as closed or open circuit is set by means of the gravity hook on the LED board (see p.c. boards of GMA 41/44W ). The alarm relays and the alarm stop relay are operated as open circuit system, the fault relay is a closed circuit. In the standard setting and without the key being plugged in, the switching functions of the relays are as follows: Relay for: The relay switches: In detection During gas alarm After gas alarm In case of mode (no gas) Not reset Reset Not reset Reset mains failure In case of failure In case of gas alarm and failure Alarm 1 Alarm 2 Alarm 3 Alarm-stop Fault 5

For the switching functions with the key plugged in please refer to the charts below. We must distinguish between two status before plugging the key in: normal detection mode (no alarm) and already activated alarm. 1. Detection mode (no alarm) When the key is turned, new alarms are suppressed. Before turning After turning Relay for: Detection mode (no gas) Detection mode (no gas) Alarm Mains failure Fault Alarm 1 Alarm 2 Alarm 3 Alarm-stop Fault 2. Alarm When an alarm is already activated before the key is turned, the switching behavior differs according to the selected model. With the standard model (non-deleting alarms) the already present alarms remain valid. New alarm signals are suppressed. Before turning After turning Relay for: Alarm Alarm Mains failure Alarm and fault Alarm 1 Alarm 2 Alarm 3 Alarm-stop Fault 6

With the alternative model (deleting alarms) the present alarms are reset, and new alarm signals are suppressed as well. Before turning After turning Relay for: Alarm Alarm Mains failure Alarm and fault Alarm 1 Alarm 2 Alarm 3 Alarm-stop Fault! It is essential to take note of the switching behavior of the relays when connecting external devices. For special settings of the relay switching functions please contact your GfG service. P.C. boards of GMA 41/44 W Before an expert changes any settings on the p.c. boards of the key-operated switch, he must turn off the operational voltage. LED card The four gravity hooks on the LED card define whether the relays are operated in open or closed circuit. Open the front cover to change the settings on the LED card. Gravity Hooks for Relays Open Circuit Closed Circuit Alarm 1 Fault Alarm 2 Alarm 3 The above picture shows the standard setting: operation of alarm relays in open circuit and operation of the fault relay in closed circuit. 7

Reverse side of the main card Open the back cover of the GMA 41/44 W to reach the reverse side of the main card. A wire bridge fixes the setting standard or alternative. The bridge is closed for the standard setting alarms non-deleting, and it is open for the alternative setting alarms deleting. Main Card (solder side) Wire Bridge crew tandard (closed) crew Alternative (open) Bus connection Bus connection Terminal diagram GMA 41/44 W Relay Relais functions, - Funktionen, see relays siehe eiten 3 und 4 Alarm 1 Alarm 2 Alarm 3 Fault Alarm top 230 V 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 17 18 Busverbindung connection GMA 41/44 W Bus connection Busverbindung 34 35 36 + + 24V DC voltage pannungsverso supply rgung Ground Masse 8

Trouble shooting Failure Cause olution No LEDs lit Operational voltage interrupted Connect operational voltage or check battery back-up Technical data GMA 41/44 W Type: Key-operated switch for snap-on mounting to DIN rail Dimensions: 106 x 90 x 58 mm (WxHxD) Current supply Operational voltage: GMA 41/44 W 24V 24V DC GMA 41/44 W 230V 230V / 50Hz or 115V / 60 Hz or 24V DC Current consumption: Maximum 100 ma at 24 V DC Maximum 2.6 W at 230V and 115 V Primary fuse: GMA 41/44 W 230V T 0.08 A econdary fuse: GMA 41/44 W 230V T 0.50 A GMA 41/44 W 24V T 0.50 A Climate conditions for operation: -10 to +55 C, 0 to 99 % r.h., 700 to 1,300 hpa Recommended storage conditions for GMA 41/44 0 to 30 C, 20 to 80 % r.h. W, spares: Output Relays: Maximum switch voltage 250V AC 50/60 Hz or 250V DC Maximum switch current 4 A AC/DC Maximum switch performance 1,000 VA AC or depending on voltage 50.. 200 W DC Relay outputs and mains connection are operation insulated DIN Rail snap-on DIN EN 50022 mounting: afety Protection: DIN 40050 - IP -20 Protective separation: By means of safety transformer GMA 41/44 W 230V Type: BV EI 306 2064 2.6VA PRI 230V / EC 18 V 50-60Hz Protective insulation: As per EN 61010 up to over voltage category III and soiling degree 2 9

1194 Oak Valley Drive, uite 20 Ann Arbor, Michigan 48108 United tates of America Phone: (800) 959-0329 or (734) 769-0573 Fax (734) 769-1888 E-mail: info@gfg-inc.comt Website: www.gfg-inc.com GfG reserves the right of modification. 606 7004-044