AirUnit. Installation instructions. mfh systems modern floor heating. Decentralised domestic ventilation

Similar documents
AirUnit. Operating manual. mfh systems modern floor heating. Decentralised domestic ventilation

Pluggit iconvent Decentralized residential ventilation with heat recovery Operating and installation instructions

Installation Manual Local Ventilation System with Heat Recovery Type e² and e² short

Instructions for Operation and Maintenance of Containers

TTV 1500 / TTV 3000 OPERATING MANUAL CONVEYING FAN TRT-BA-TTV TC EN

INDEX RECOMMENDATIONS AND SUGGESTIONS... 4 CHARACTERISTICS... 5 INSTALLATION... 6 USE... 9 MAINTENANCE... 11

Katherm NE - Natural convection with electric heating element 2.45

THROUGH-WALL AIR-TO-AIR HEAT PUMP AND AIR CONDITIONER. Instruction Manual. Model AMB-12H

USER S MANUAL. Centrifugal inline fan. VKMz 100 Q VKMz 100 VKMz 125 Q VKMz 125. VKMz 250 Q VKMz 250 VKMz 315 Q VKMz 315

SINGLE-ROOM REVERSIBLE UNIT WITH HEAT AND HUMIDITY RECOVERY VENTO V50-1 OPERATION MANUAL

PRODUCT INFORMATION. Sounder SG 200. BDL F.01U A3.en / ST FIR/ PRM1 / zab. Page 1 of 10

EN Instruction on mounting and use

Table of Content LT 5165-UL

IDE 20 / IDE 30 / IDE 50 IDE 60 / IDE 80

Hygro and Hygrothermal Transducers (Capacitive) for Air Conditioning Applications

Installation manual Mini Comfort 50 S/L 07/ V EN

Silvento concealed variant clamped-ventilator - Replaces Skalar-; Skalar-V...; Skalar-2V... - Installation directions - Please pass on to the user -

LEIHDC70SC - LEIHDC70BB LEIHDC70BC. Instructions Manual.

Installer manual AG-WL10

GB Operating instructions

3-way switching valve

AIRGOCLEAN 10 E OPERATING MANUAL AIR CLEANER TRT-BA-AIRGOCLEAN10E-TC-001-EN

INSTALLATION AND USER S MANUAL COOKER HOOD RS-600/A-S

TEMPAIR 3 IN 1 EXHAUST FAN SKU# &

EHA Hoffmann International GmbH

ELTSHDC110SG/ Users Guide & Installation Instructions

FLANGED CORR/GUARD CORR/GUARD INSTALLATION INSTRUCTIONS

TDS 20 R / TDS 30 R / TDS 50 R

SOUND-INSULATED FAN. Iso-K OPERATION MANUAL. Iso-K_v.1(2)-EN.indd :20:59

1. Contents Principle General information Parts list Assembly Technical drawing... 18

Carbon Film Installation Instructions

Atmos EasySolar. Installation Instructions for. In-roof and flat roof installation with flat plate collectors

Warnings, Safety Information and Guidance

SINGLE-ROOM ENERGY RECOVERY VENTILATORS

Decentralised comfort ventilation unit Zehnder ComfoSpot 50

GUH90 90 cm Canopy Hood

Ventilator insert Silvento V... Installation directions - Please pass on to the user -

FSW300 Series Flow Switch

TIH 300 S / TIH 400 S / TIH 500 S / TIH 700 S / TIH 900 S / TIH 1100 S

Instructions for use. Gas hobs for installation in worktops GKS GWS GKS GKS

Mechanical seals external, single or double, to DIN EN 12756

Instruction Manual. Orayonne. Glass radiation heater

Illustration shows item no Z Original operating manual. Operating manual. BlueMobil eco. Item no: Z-3278

Operating Instructions. Accessory Units Melitta Cafina XT Series. Melitta Professional Coffee Solutions

Sanpress Inox G. Instructions for Use. Year built: from 02/2004 en_int

AZSG10000/AZSG10005/AZSG10010 ABUS Wired Outdoor Siren

Dipl.-Ing. W. Bender GmbH & Co. KG Londorfer Str Grünberg Phone: Fax:

Handling or using the product improperly and in disregard of the instructions with this mark might result in serious bodily injury or death.

Händetrockner Hand dryer Sèche-mains Handendroger Osoučeč rukou Suszarka do rąk Сушилки для рук Kézi szárító

BR342 Ducted Installation Instructions Australian Version Electronic Wall Control

Atmos EasySolar. Installation Instructions for. Sloping roof and flat roof installation with evacuated tube collector

HR200WK Through the wall Heat Recovery Ventilator

2CKA001473B System Manual Busch-Infoline. Handicapped toilet signal set 1510 UC

IdealFILM. Do-It-Yourself Installation Manual

Remote alarm indicator and test combination MK2430

AC THOR. Assembly Instructions

C o o l i n g a n d h e a t i n g s y s t e m s

INSTALLATION GUIDE ISODRIVE MOTOR. ST - 900m 3 /hr.

Popcorn Warmer Cabinet

Installer manual AG-AA10. Air/air heat pump IHB GB AG-AA10-30 AG-AA10-40/50

Operating Manual. Please keep this manual. with the unit! Cooling Unit. For Heat Recovery Unit santos (F) 570 DC. Status:

USER S MANUAL NKP. Duct heater for supply air pre-heating with external control

VH60SS 60CM VISOR HOOD STAINLESS STEEL

Operating manual 1 SAFETY REGULATIONS AND INFORMATION. Original operating manual INDEX. RG CPAP 24 V mit Powermodul 24V sensorless

Bedienungsanleitung. Ideas for dental technology. Made in Germany C

IDE 20 D / IDE 30 D / IDE 50 D / IDE 60 D / IDE 100 D

Waste water ejection unit

Instruction manual for downdraft hood

Installation and maintenance manual

Ceiling Mount Air Purification System

Fillmore Small Pendant Assembly and Installation Instructions

CHAPTER 8 CHIMNEYS AND VENTS

Flow switch. Operating Manual. English manual page Page 1 of 15 Fax:

Swegon CASA R120. Ventilation unit with rotary heat exchanger HOME VENTILATION

IMPORTANT NOTES. Electric Underfloor Heating Mats For use with Touchsceen underfloor heating Thermostat

INSTALLATION MANUAL. Split-type Air Conditioner (Cooling and Heating) Outdoor Unit UQB09JJWC UQB12JJWC. Indoor Unit AQB09JJWC AQB12JJWC

THERMOFILM CONVECTIVE PANEL HEATER INSTALLATION, OPERATION AND MAINTENANCE MANUAL. Models: CP 2400 CP 2000 CP 1500 CP 1000 TABLE OF CONTENTS

Lo-Carbon SELV Tempra

AIR HANDLING UNIT WITH HEAT RECOVERY

Operating manual 1 SAFETY REGULATIONS AND INFORMATION. Original operating manual INDEX 2218 F/2TDH4P

EH0533 Indoor Climate Control

LYRA 1000 VVS Installation and Operation Manual LYRA 1000 VVS THERMAL STORE LYRA 1000 VVS

LUNOS Domestic Ventilation Systems With Heat Recovery. Innovations for New Buildings and Redevelopment. e2 + e go

Single Wall Flue system. Installation manual WARNING. Installation Manual CoxDENS PPs MC-CG-105 EN_892054

JLBIHD624 60cm Cooker Hood

Truma VarioHeat eco AU. Installation instructions Page 2

90cm Chimney Extractor

MILLA ELECTRIC FIREPLACE

Inspection Checklist Mechanical Rough in

INSTALLATION GUIDE. Isodrive / V1.0

MULTIWASH XL OPERATOR S MANUAL & PARTS LIST PFMW18. Save These Instructions

Installation Instructions T 9822 Gas Dryer. en - US, CA. To prevent accidents

ASX7-4-IOM-6 J

Installation Instructions Use and Care Guide Instructions d installation Mode d emploi et d entretien

INSTALLATION AND OPERATION INSTRUCTIONS FOR BI-DEEP UNITS

Trumatic E. Trumatic E 2400 (Australia) Operating instructions Page 4 Installation instructions Page 7. To be kept in the vehicle!

Assembly instructions and instructions for use for electric sauna oven with evaporator. Bi-O-Mat W MADE IN GERMANY IPX en / -44.

Installation instructions

s l it l on for Infrared Heaters

Hygro and Hygrothermo Transducers (capacitive) for climatic applications

Transcription:

mfh systems modern floor heating AirUnit Decentralised domestic ventilation Installation instructions

List of contents, Installation instructions Page 1. General information... 03 2. Function / planning information... 04 3. Delivery units / scope of delivery... 05 4. Dimensions / technical data... 06 5. Selection of the installation location... 07 6. Installation of wall duct... 07 7. Installation of AirUnit controller... 09 8. Electrical connection... 10 9. Completed installation / function check... 12 Symbols The following symbols are used in the manual for labelling particular information: General information / information Warning information Information: Hazard due to electrical voltage Installation / maintenance information 02

1. General information The AirUnit and controller are constructed according to state of the art technology and the recognised safety regulations. Installation and maintenance work of the ventilation unit may only be implemented by trained specialist personnel under compliance with the regulations for occupational safety and accident prevention. The electrical connection must be implemented according to VDE 0100. For installation and maintenance work, disconnection from the mains at all poles with at least a 3 mm contact opening width must be undertaken. The mains disconnection is to be secured against re-connection! Use of this device is only permitted for the intended use. Incorrect usage, defectively implemented installation or maintenance work and design changes can impair the function and safety of the ventilation unit and lead to the termination of any warranty claims. Prior to beginning installation / maintenance work, read this manual carefully and observe the information provided for installation and maintenance. Prior to the installation of the device, check the delivery with regard to completeness and integrity, and in case of missing or damaged parts contact your supplier directly. Intended use AirUnit with heat recovery are designed for controlled room ventilation. The devices may only be used exclusively for the conveyance of air. The conveyance of aggressive, flammable or extremely dusty media is not permissible. Never operate the device without the filter which is inserted in the device. The connection of ventilation ducts is not permissible. AirUnits are not suitable for construction drying; operation of the device should only be implemented after completion of the construction activity. The operation of the device in connection with fireplaces possibly requires additional safety equipment (Feuerungsverordnung FeuV - German Fire Code Ordinance). Corresponding information can be obtained from the chimney sweep responsible for your region. Device location AirUnits may only be installed and operated indoors. When selecting the location for the device, take into consideration that the ventilation unit is accessible for inspection and maintenance work. Installation of the device in close proximity to flammable liquids or gases is not permissible. A mains connection (230 V / 50 Hz) is required to the controller for operation of the device. Installation For the installation of the AirUnits, the recognised rules of engineering (ARdT) are to be observed with regard to device installation, electrical work, fire protection etc. and the specifications for the ventilation of living spaces (DIN 1946-6). 03

2. Function The AirUnit is a decentralised ventilation system for the control of room ventilation with heat recovery. The use of several devices in pairs makes the ventilation of complete residential units / building possible. For operation with heat recovery, the ventilation unit works in 2 time intervals. In the first interval (exhaust phase) the air in the room is led outside via the exhaust operation of the ventilator. In this process, the air flows through the ceramic heat accumulator contained inside the ventilation unit and is heated. In the second interval (air feed phase), the ventilation unit is inverted and fresh external air is led into the room via the ventilation unit. In this process, the air flows through the heat accumulator, which emits the previously stored heat to the air. In this way, heat recovery of up to 90% is achieved. The principle of loading and unloading a heat accumulator is designated as being regenerative. With the operation of a single device, a positive pressure (air feed phase) or a negative pressure (exhaust phase) is created in the room to be ventilated, depending on the operational phase. In order to ensure a balanced ratio between feed and exhaust air volumes, use of the AirUnit devices in pairs is recommended. The controller enables joint operation of up to three device pairs. 2.1 Planning information Prior to the installation of AirUnits, a ventilation concept should be created in which the number of AirUnits, their installation location, the ventilation principle (cross-ventilation, single-room ventilation) and the position / number of the associated controller can be found. AirUnits enable the following ventilation variants: The ventilation of a room using a AirUnit, in intervals changing between feed / exhaust air mode with heat recovery, alternately feed* or exhaust air mode* (* depending on the electrical connection, see Page 10). The ventilation of a room or a utility unit using ventilation units operated in pairs, in intervals switching between feed / exhaust air operation with heat recovery (whilst one device of a device pair operates in feed mode the assigned second device operates in exhaust mode; the air direction of both devices alternates in the next interval), alternately feed* or exhaust air mode* (* depending on the electrical connection, see Page 10). AirUnits should be operated in pairs if possible (see Function). The device pairs can be used either in one room or also for groups of rooms. Within an utility unit, an arrangement across different storeys is also possible. An air flow between the rooms to be ventilated must be enabled through sufficiently dimensioned overflow openings (e.g. door air grids or shortened doors). As a result, odour transfer into other rooms does not occur through the air blown in (feed phase ventilation unit); for the ventilation of kitchens, bathrooms or toilets with windows, two anti-cyclically operating devices should always be installed. In inner, windowless kitchens, bathroom and toilets, AirUnit devices may not be used, as connection of the device to a duct or pipe is not permissible. The use of an exhaust ventilator is recommended in this case acc. DIN 18017 T.3. Likewise, device installations in cellar rooms with light shafts is not possible, as recirculation of the exhaust air cannot be excluded. In order to prevent recirculation with the facade installation of devices, a minimum distance of 1.0 m should be maintained between the single devices. In case the building location is exposed to the wind (medium wind speed > 5 m/s), we recommend that you do not use this device. In order to prevent draft occurrence through the operation of the ventilation units, the devices should not be placed directly in areas where people stay for prolonged lengths of time (seating areas, beds). Ensure that the air flow in the room is not impaired by furniture or curtains. 04

3. Delivery units / scope of delivery A complete AirUnit comprises of a NEOPOR wall duct and a ventilator unit inserted into the wall duct. The ventilator unit comprises of a reversible ventilator (12 V/DC), ceramic heat accumulator for heat recovery, a filter (G3) and sealing rings which are inserted into a wire assembly incl. protection grid and enclosed by a housing pipe. Furthermore, all ventilation units are delivered with an additional sound insulation mat. The air flow in the room takes place via a closable and sound-insulated design screen. The exterior air flow occurs via a weather protection hood. The operation of the device occurs via the controller with operating panel (accessory). Up to six AirUnits (3 x feed 3 x exhaust) can be controlled via the controller. The installation of the controller occurs in a device double socket, e.g. flush-mounted, double cavity wall socket. The following delivery units are available: AirUnit 500: Ventilation unit with wall duct 495 mm, ventilator unit, interior design screen (RAL 9016) and weather protection hood (RAL 9016). AirUnit 500 stainless steel: Ventilation unit with wall duct 495 mm, ventilator unit, interior design screen (RAL 9016) and weather protection screen made from stainless steel. AirUnit 1000: Ventilation unit with wall duct 1000 mm, ventilator unit, interior design screen (RAL 9016) and weather protection screen (RAL 9016). AirUnit 1000 stainless steel: Ventilation unit with wall duct 1000 mm, ventilator unit, interior design screen (RAL 9016) and weather protection screen made from stainless steel. Controller: For up to 6 AirUnits (3x feed, 3x exhaust) incl. cover frame. 1 2 3 4 5 6 7 8 9 10 11 1 Filter (G3) 2 Ceramic heat accumulators for heat recovery 3 Ventilator (12 V/DC) 4 Sound insulation mat 5 Exterior hood (weather protection screen in RAL 9016 or stainless steel) 6 Sealing ring (heat accumulator) 7 Housing pipe 8 Sealing ring (ventilator) 9 Wire assembly incl. protection grid 10 Wall duct (495 or 1000 mm) 11 Interior design screen 05

4. Dimensions AirUnit (all dimension information in mm) 11mm 10 495 alternatively 1,000 45 222 AirUnit interior screen 4.1 Technical data Controller 223 AirUnit weather protection screen AirUnit Air output 15 20 30 40 m³/h Degree of efficiency of the heat exchanger up to 90% Supply voltage 230 V/50 Hz Power consumption 0,8 1,1 1,7 2,7 W Sound pressure level (1m)* 21 28 31 40 db(a) Sound pressure level (3m)* 12 18 22 30 db(a) Filter category G3, regenerative Permissible operating temperature -20 bis +40 C Protection class III Weight ~ 2.5 kg ø wall duct (interior / exterior) 154 / 198 mm Length of wall duct 495 / 1000 mm * Internal measurement, average valure of exhaust and supply phase room-side Controller Operating modes Power unit Switch range Input Output Protection class Controller controller 4 performance levels (optional 3 performance levels + OFF) winter and summer mode up to 6 devices including cover frame 2 times and blank cap 230 V / 50 HZ 12 V DC 24 W IP 00 (without cover) 06

5. Selection of the installation location On selecting the installation location, observe the exterior view of the building. In order to harmoniously integrate the devices into the building facade, the devices should be installed at the same height / with the same distance to the windows, for example. Observe the dimensions of the exterior or room-side air passages. It is recommended that you maintain a minimum distance of 200 mm around the wall duct to the neighbouring facade components / elements and room corners! The AirUnits devices may not be covered by furniture or curtains. Recommended minimum distance for the installation of a device pair in a wall: Recommended minimum distance for the installation of a device pair across a corner: 6. Installation wall duct Wall ducts in two different lengths are available for the AirUnits: Pipe length 495 mm Pipe length 1000 mm The AirUnit is delivered with 495 mm or 1000 mm-long wall ducts, all wall ducts are manufactured with an integrated gradient to the outside for the drainage of condensate (observe the room-side labelling, see Fig. below.) Roomside below 07

6.1 Core drill hole wall duct Prepare a core drill hole with a diameter 200 mm and create a cable slot for the connection lines. 6.2 Installation wall duct Insert the wall duct into the wall opening and leave the wall duct protruding if required (e.g. for additional plaster or insulating layers) according to the room and facade. Observe that the gradient slopes to the exterior or the room-side labelling of the wall duct. Seal the wall duct with the masonry on the interior and exterior with an appropriate sealant. For larger wall openings, the cavities between the wall opening and the wall can be filled with non-pressing installation foam. The wall duct can be trimmed flush with a carpet knife after the completion of the wall. Caution: In order to ensure tension-free installation / removal (maintenance) of the ventilator / heat accumulator in the wall duct, deformations of the wall duct through external pressure / tensions are to be avoided! Observe that the wall opening is installed with a gradient to the outside at all times. 08

6.3 Wall duct insertion, ventilation unit connection pipe Insert the connection pipe (min. 3 x 0.60 mm²) laterally (room-side view) into the wall duct. Allow the connection pipe to protrude in length past the wall duct. Close the wall duct on the interior and exterior side using the supplied wall covers (see Page 14), in order to prevent contamination of the wall duct. 7. Installation controller The controller is designed for installation in a device double socket. It can be used to control up to six AirUnits. The controller is to be connected as stationary equipment with permanently laid lines. Electrical connection diagram, see page 10. The supply voltage of the controller is 230 V/50 Hz; a sheathed cable 3 x 1.5 mm² (e.g. NYM-J 3 x 1.5 mm²) is recommended as a supply line. Control of the ventilation units occurs via 12 V DC, therefore under no circumstances may the ventilation units be connected to the 230 V mains voltage of the control electronics. A sheathed cable min. 3 x 0.60 mm² is recommended as a connection line for the AirUnits. 09

8. Electrical connection The electrical connection must be implemented according to VDE 0100. For installation and maintenance work, disconnection from the mains on all poles with at least 3 mm contact opening width must be undertaken. The mains disconnection is to be secured against reconnection! Connection controller Device 1 PWM PURPLE Device 3 PWM PURPLE Device 5 PWM PURPLE Connection feed devices External inputs, see page 11 PWM PURPLE Device 2 PWM PURPLE Device 4 PWM PURPLE Device 6 Connection exhaust air devices The connection of several devices occurs arranged in pairs at the plug connectors device 1 - device 2, device 3 - device 4, device 5 - device 6; in paired operation one device of a device pair operates in feed mode, the second assigned device in exhaust air mode The air flow direction of both devices is alternated at intervals. The AirUnits connected to the plug connectors device 1, 3 or 5 serve as feed devices in summer mode. The AirUnits connected to the plug connectors device 2, 4 order 6 become exhaust devices in summer mode. Therefore cross-ventilation can occur with the use of several devices i.e. in order to convey cool outside air into the building during summer nights. PE N L1 Mains connection 230 V / 50 Hz With the use of a single device, the AirUnit can be used as a feed or exhaust device in summer mode. 8.1 Connection AirUnit(s) controller Ventilation device PWM PURPLE Controller RED +12 V PURPLE PWM BLUE Gnd The connection of the AirUnits to the connection line of the controller is implemented via a plug connector contained within the scope of delivery of the ventilation units, as depicted previously. Please observe the polarity feed / exhaust devices (see Fig. above)! 10

8.2 Electrical connection of external control elements The adjustment of operation mode on the AirUnits occurs as required by the user via the operating panel on the controller. Different operating variants with different performance levels can be selected. Through the connection of optional, external control elements, a time or humidity-dependent device operation can be additionally activated. The connection of external control elements occurs via connection plugs external inputs on the rear side of the controller as depicted below. The device function with an external control is described from Page 7 Operating manual onwards. Connection of external control elements Optional external humidity control (e.g. hygrostat) Function description, see Page 7 Operating manual H% Connection plugs, external inputs Device 5 PWM LILA PWM LILA Device 6 Optional external switch-off (e.g. time switch) Function description, see Page 7 Operating manual Connections feed devices (max. 3 pieces) Connections exhaust air devices (max. 3 pieces) PE N L1 Mains connection 230 V / 50 Hz A data line is recommended (e.g. 2 x 2 x 0.6 (z. B. J-Y(ST)Y)) for the connection of external control inputs (potential-free contacts). 11

9.1 Complete installation After completion of the insulation / plaster work, remove the wall covers on the interior and exterior side. Adapt the wall duct to the dimensions of the finished wall by trimming the wall duct flush with the room or facade side using a carpet knife or a hot wire. To protect against water penetration into the wall opening, the facade-side transition to the wall duct must be sealed circumferentially using a suitable sealant! Adhere the supplied sealing tape circumferentially to the rear side of the outer wall panel. Subsequently, install the wall panel to the weather protection hood using suitable attachment elements. Install the weather protection hood to the AirUnit. The hood is mounted onto the attached brackets on the upper edge of the wall panel and attached to the wall panel using the supplied attachment screws. 12

Install the inner wall panel using suitable attachment elements and carefully insert the ventilator unit (ventilator faces towards the room) into the wall. Observe that in the process the connection pipe of the ventilator is not bent / damaged. The ventilator unit can be aligned above the protection grid during the installation and be pulled back out of the wall duct again for maintenance purposes. Subsequently, connect the plug connectors of the connection line to the controller (for details see Electrical connection Page 10). Circumferentially insert the sound insulation mats with a distance of min. 3 cm to the ventilator unit on the room side. Push the inner screen onto the hinge of the wall panel. The inner screen can be closed as required by means of the magnetic closures. In an open state, the inner screen is open at the top with an aperture angle of approx. 10. 9.2 Function check After completion of the installation work, the function of the device has to be checked. Prior to inspection, ensure that the air passages of the ventilation unit are free from installation debris / foreign objects, and that all electrical work has been implemented and completed professionally! After switching on the power supply (normally via the automatic circuit breaker of the electrical installation), the AirUnit can be commissioned via the operating panel of the controller. During commissioning, check all the device functions described in the Operating manual from Page 6 onwards. During the inspection, check for quiet, smooth operation of the ventilator motor. Determined malfunctions or faults on the AirUnit must be rectified prior to final commissioning of the device; possible error sources and their rectification are described in the chapter Malfunctions (see Page 11 Operating manual). Document the properly-executed installation / function check of the ventilation unit(s) in the Commissioning log (separate form). 13

Wall cover folding instructions 1 2 3 4 5 6 14

15

mfh systems GmbH Hager Feld 8 49191 Belm-Vehrte Germany Fon +49 (0) 54 06 699 95-10 Fax +49 (0) 54 06 699 95-90 mail@mfh-systems.com www.mfh-systems.com