GAS FLOODING SYSTEM FOR CIFF AT BASEMENT

Similar documents
PRICE BID. UNIT QTY Rate in Figure Rate in words Amount DESCRIPTION OF ITEM D: FIRE PROTECTION SYSTEM

ENGINEERING PROJECTS (INDIA) LTD. (A Govt. of India Enterprise) Signature of Bidder 1 of 11 EPI

SUPPLY,INSTALLATION,TESTING AND COMMISSIONING OF SPRINKLER SYSTEM AND FIRE ALARM SYSTEM FOR AIR INDIA LIMITED AT SHAMSHABAD, HYDERABAD.

SECTION FM-200 FIRE SUPPRESSION SYSTEM

PAT E N T System 88. COMPLIES WITH Singapore Standard : SS CP10 : 2005 British Standard : BS EN54-2 : 1998 BS EN54-4 : 1998 REV.00

Amerex Clean Agent System with FM200. Potential Applications: System Coverage Overview: Approvals and Standards:

ORENA BRAND CONVENTIONAL (ORENA Brand) CE

SECTION CLEAN AGENT FIRE SUPPRESSION SYSTEMS

Control Panels and Fire Detection Equipment

CO2 COCO GAS FLOODING SYSTEM

CERTIFICATE OF APPROVAL No. ME 5008 EMIRATES FIRE FIGHTING EQUIPMENT FACTORY LLC (FIREX)

SPECIFICATION: CARBON DIOXIDE ENGINEERED FIRE SUPPRESSION SYSTEM

CERTIFICATE OF APPROVAL No. ME 5005 EMIRATES FIRE FIGHTING EQUIPMENT FACTORY LLC (FIREX)

Copyright 2013 Fike 12/13 SECTION CLEAN-AGENT FIRE-EXTINGUISHING SYSTEMS PART 1 - GENERAL 1.1 RELATED DOCUMENTS

FIREBETA EXTINGUISHING CONTROL PANEL (ECP)

SECTION TOTAL FLOODING ECARO-25 CLEAN AGENT FIRE EXTINGUISHING SYSTEM

FIRE SUPPRESSION SYSTEM

Consultant Specification AGILE Wireless Fire Detection System

Conventional Releasing Control Panel

Carbon Dioxide Fire Suppression Systems

CORE Protection Fire System Specification

FM-200 In-Cabinet Series

SPECIFICATION FOR A TOTAL FLOOD ECARO-25 TM CLEAN AGENT FIRE SUPPRESSION SYSTEM FOR USE WITH THE SHP PRO CONTROL PANEL SYSTEM

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 03/29/2017

Specification/ Data Sheet

Revised March 2015 Fire Alarm Systems Verification. Schedule I(A) Services. *Manditory Site visit required*

NFPA 2001: Standard for Clean Agent Fire Extinguishing Systems NFPA 70: National Electrical Code (NEC) NFPA 72: National Fire Alarm Code

Catalogue Telecommunication Cables INTRODUCCIÓN

SPECIFICATION FOR A TOTAL FLOOD ECARO-25 TM CLEAN AGENT FIRE SUPPRESSION SYSTEM FOR USE WITH THE CHEETAH Xi 50 CONTROL PANEL SYSTEM

designed for rail 5000 Series

Power Cables. Introduction 3 RV 4 RVMV 5 RVSV 6 RVFV 7. ELECWIRES 2 Page

Reliably Advanced Extinguishing Control

PSN-1000 & PSN 1000(E) Installation Manual

Copyright 2013 Fike 12/13 SECTION CLEAN-AGENT FIRE-EXTINGUISHING SYSTEMS PART 1 - GENERAL 1.1 RELATED DOCUMENTS

Catalogue Power Cables

16.34 Multiplex Fire Alarm System Construction Standards Page 1 of 5

Installation, Operating and Maintenance Manual

PWGSC Ontario MULTIPLEX FIRE ALARM SYSTEM Sect Region Project Page 1 Number R

Liberty Township Fire Department Fire Prevention Bureau. Clean Agent Fire Protection Plan Submittal Checklist

DESIGN PHILOSOPHY FOR FIRE ALARM & DETECTION SYSTEM

SPECIFICATION FIKE CLEAN AGENT FIRE SUPPRESSION SYSTEM WITH IMPULSE VALVE, FK AGENT & CHEETAH Xi 50 CONTROL PANEL

TECHNICAL DATA OBSOLETE

SPECIFICATION FIKE CLEAN AGENT FIRE SUPPRESSION SYSTEM WITH IMPUSLE VALVE, Fike FK AGENT & SHP PRO CONTROL PANEL

ELECTRONIC SOUNDER STROBE Model : AVD-C407

PNC 1000 SERIES 2, 4, 8 Zone Fire Alarm Control Panel

- Four (4) Fused Outputs - Four (4) PTC Outputs. - Eight (8) Fused Outputs - Eight (8) PTC Outputs

Engineering Specifications

Tratos Railway Cables

SPECIFICATION: ECS SERIES CLEAN AGENT FIRE SUPPRESSION SYSTEM

TECHNICAL SPECIFICATION FOR FIRE DETECTION & ALARM SYSTEM INCLUDING FIRE EXTINGUISHERS

CLEAN AGENT SYSTEMS. TABLE 1 Agents Recognized in NFPA 2001

Catalogue. Instrumentation & Control Cables

Reliably Advanced Extinguishing Control

Overview. Wireless Overview QLD NSW VIC Fundamentals. Operation. Features.

C E R T I F I C A T E O F C O M P L I A N C E

The supplier and installer of the system should be approved by the local civil defence authority.

SECTION KITCHEN HOOD AND DUCT FIRE SUPPRESSION SYSTEM

SPECIFICATION FIKE CLEAN AGENT FIRE SUPPRESSION SYSTEM WITH IMPULSE VALVE, FK AGENT & CHEETAH Xi CONTROL PANEL

STORED PRESSURE YES TEST STANDARDS: CAN/ULC S504 & ANSI/UL 229 CAN/ULC S508 & ANSI/UL 711. Available Options: Stationary Design Tow Loop

XC10 combined fire detection and extinguishing control

Telecommunication Cables

KITCHEN HOOD AND DUCT FIRE SUPPRESSION SYSTEM

Release Control Fire Alarm Systems

A. NFPA 2001 Standard for Clean Agent Fire Extinguishing Systems 2004 edition.

ORION Mini-Rep INSTALLATION MANUAL

SPECIFICATION: Kidde Engineered Fire Suppression System Designed for use with 3M Novec 1230 Fire Protection

Havells Fire Survival Cables

An introduction to... Sigma

AND ARCHITECT SPECIFICATIONS

D250A/D253/D261AW/D280A/D290 Series

AL600ULX Series. Power Supply/Charger. Installation Guide

Functional Performance Test

Data Sheet Fire Safety & Security Products. System Overview. Initiating Circuits SXL-EX FACP 7906

CITY OF PORTSMOUTH Department of Public Works MUNICIPAL COMPLEX FIRE ALARM. Bid # Addendum #1

- Four (4) Fused Outputs - Four (4) PTC Outputs. - Eight (8) Fused Outputs - Eight (8) PTC Outputs

Safe, Effective, Environment-friendly

SPECIFICATION MICROMIST FIRE SUPPRESSION SYSTEM WITH SHP-PRO CONTROL PANEL

ENGINEERING SPECIFICATIONS FOR FM-200 CLEAN AGENT INDIRECT PRE-ENGINEERED FIRE SUPPRESSION SYSTEMS

SPECIFICATION: DRY CHEMICAL FIRE SUPPRESSION SYSTEM FOR INDUSTRIAL APPLICATIONS MODEL IND

Intelligent addressable fire alarm control panel

Table-1: Clarifications and modification in tender specifications based on Pre-bid meeting discussion

Conventional Smoke Detectors KFAPO

NAME OF WORK - IIM AHMEDABAD - LIBRARY BOQ OF ELV WORKS Item #

TABLE OF CONTENTS GENERAL... 2 A. DEFINITIONS DIGITAL, ADDRESSABLE FIRE ALARM SYSTEM... 2

Enclosure 4- RISK ASSESSMENT

BOQ FOR FIRE HYDRANT & FIRE ALARM SYSTEM AT T.I.E

SPECIFICATION MICROMIST FIRE SUPPRESSION SYSTEM WITH CHEETAH Xi 50 CONTROL PANEL

Hospitals and Major Medical Centers

USER MANUAL COMBINED FIRE & EXTINGUISHING CONTROL PANEL COMPLIES WITH BS EN PART 1 & EN54 PARTS 2 & 4

Reliance Fire Protection Systems

Wireless Fire & Security Solutions. Fire Product Showcase

Request for quotation (RFQ) for goods/services

PRODUCT LISTING DATA SHEET (Active Fire Protection Equipment)

EXTINGUISHING SYSTEM DETECTION AND CONTROL

CARBON DIOXIDE FIRE EXTINGUISHING SYSTEM

ZXe INTELLIGENT MULTI PROTOCOL FIRE ALARM CONTROL PANEL

Total Fire Solutions. Includes BS 8519 and the updated BS :

IEC UNE DESIGN. 1. Conductor. 2. Insulation. Cross-linked polyethylene (XLPE) 3. Outer sheath. Flexible PVC, black colour.

PEGAsys. Multi-Loop Intelligent Suppression Control System FEATURES DESCRIPTION. Effective: March 2007 K

MS-4012/4024 and CMS-4012/4024. Instruction Manual for the. Fire Alarm Control Panels

Transcription:

CONSTRUCTION OF BUILDINGS FOR LABORATORIES AND ASSOCIATED FACILITIES INSTEM BANGALORE SCHEDULE OF QUANTITIES FOR (EQUIPMENT ROOM 3 & 4) Sl.No. Description Unit Quantity Rate (in INR) in figure HFC-227ea GAS BASED FIRE SUPPRESSION SYSTEM COMPRISING OF PROVIDING ALL MATERIAL, EQUIPMENT, INSTALLATION, LABOUR, TESTING, COMMISSIONING & HANDING OVER OF THE ENTIRE SYSTEM, WITH THE FOLLOWING COMPONENTS: 1 Providing & fixing 80 Liters Capacity Seamless Steel Cylinder Complete with Pneumatical Valve Assembly arrangement, supervisory switch connection for minitoring cylinder pressure, in compliance with Chief Controller of Explosive, Nagpur with electric & pressure operated control heads as per requirement (Master/Slave Actuation Packages) a safety burst disc, and any other accessories to make the cylinder completely operational including Flexible Actuation Hose (directed to a pressure operated control head on each cylinder valve using 1/4 inch actuation hose), container strap, structural supports etc. 2 Providing HFC-227ea Gas, factory-filled in the Gas Cylinder/ from a UL-Listed Gas Filling Station, as per the specifications and manufacturer recommendations/ specified design concentration and fill density. Kgs. 116 3 Providing & Fixing Discharge Nozzles designed to provide the proper flow rate and distribution of gas to total flood a hazard area : (180/360 deg. As per requirement) 4 Providing & Fixing Micro-processor based Alarm Panel (addressable panel of single loop) for required devices capacity, discharge module with minimum 80 character LCD type display & LED indication for all zones, complete with internal sounder, alarm/fault indications & standby 24 v lead acid batteries with charger. This panel needs to be compatible with the central BMS/BAS System through interface convertors. Nos. 1 5 Providing & Fixing Gas Release Panel with 2-Zone Fire detection and 1-Zone gas discharge module with binary switch timer for release delay and potential free contact to relay "Gas Release" signal panel. This panel needs to be compatible with the Fire Alarm Panel and shall be UL Listed. No. 1 6 Providing & Fixing Electronic Hooter with flashing type multi-strobe for combined audio + visual alarms, to be wired and located as per instructions of the engineerin-charge. Page 3

Sl.No. Description Unit Quantity 7 Providing & Fixing Abort Switch of approved Pull- Type, as per approved location Nos. 1 Rate (in INR) in figure 8 Providing & Fixing Release Switch as per approved location. Nos. 1 9 Providing & Fixing Key-operated selector switch between the Main and Reserve Gas Banks. Nos. 1 10 Providing & addressable Photoelectric/ Ionization Smoke detectors complete with mounting base LED, address switch, as per requirements. 11 Providing & Fixing 1.5mm X 2 core Fire Survival Armoured cable, with Copper conductor (600/1000V) having Cross linkable Ethylene Propylene Rubber (EPR) insulation with Low Smoke Zero Halogen (LSZH) inner & outer sheath, basic design as per BS- 7846:2009 / IEC 60502 Part-1:2004. Should retain Circuit Integrity @ 8500C for minimum period of 2 Hrs as per BS 8519:2010, BS 8491:2008 Cat.3 (120 mins.), BRE Global UK Certified or approved Equivalent. Metre 40 12 Providing & Fixing MS pipes (Seamless piping as per ASTMA 106, Grade 'B' Schedule 40) including all necessary fittings for all low side piping, and MS pipes (Seamless piping as per ASTMA 106, Grade 'C' Schedule 80) for Manifold for 2 nos. Cylinders. (1 Working + 1 Standby) including all necessary fittings as per NFPA 2001 guidelines including all structural supports. Lot. 1 13 Providing & Fixing Interface module for communication between Gas Release Panel and specified compatible devices as per the instructions of the engineer-in-charge. Nos. 1 14 Making Electrical Connections to the Fire Alarm Main Panel including all necessary material and accessories as per requirements and as per instructions of the engineer-in-charge. Job 1 15 Providing & fixing Photo-luminiscent Gas Release caution sign boards for approved locations. Nos 2 16 Providing HCFC Blend E /Halotron type fire extinguisher complete with discharge nozzle/ hose for manual operation ( 5 Kgs Capacity) Nos. 1 Page 4

Sl.No. Description Unit Quantity 17 Providing & fixing M.S. structural work fabricated from standard section e.g. M.S rounds, angles, channels, plates including cutting to size,drilling,welding fixing and welding to insert plates in RCC structural members as directed by engineer-in-charge including cutting and making good the walls, ceilings and floors. (As per the Instructions of the Engineer-In-Charge) Kg. 300 Rate (in INR) in figure 18 Performing dump test for UPS room of Gas discharge test with nitrogen gas (HFC 227ea gas shall not be used) complete i.e. checking of the Fire detection and alarm system room integrated test (Procedure of testing shall be as per NFPA 2001) LS TOTAL C/O TO SUMMARY IN RS Page 5

in words Page 6

in words Page 7

in words Page 8