luxcontrol lighting control system basicdim basicdim ILD 5DPI 14f Compact control module with ambient light sensor and motion sensor

Similar documents
luxcontrol lighting control system basicdim basicdim ILD 5DPI 14f Compact control module with ambient light sensor and motion sensor

luxcontrol lighting control system basicdim basicdim ILD 16DPI 69f Compact control module with ambient light sensor and motion sensor

11,9. Ordering data. Max. cable length sensor head 1 basicdim ILD lx 150 lx m 1

luxcontrol lighting control system basicdim basicdim ILD Compact control module with ambient light sensor and motion sensor

11,1 30. Ordering data

DALI MSensor 02 Multi-sensor for DALI system

DALI MSensor 02 Multi-sensor for DALI system

luxcontrol DALI basicdim DGC Product Manual

Installation Instruction

LPCMPIRM65 & LPCMPIRDSI65

LPC3BSP65 & LPC3BDP65

, ,

PRESENCE DETECTOR. PD-C360i/8 mini KNX PD-C360i/12 mini KNX / 13 7 REMOTE CONTROL PRESENCE DETECTOR

PIR/INT & PIR/INT-D. Batten mount PIR detectors. Product Guide. Overview. Features

Detector switch - Dual Tech

EBMPIR-MB. Batten mount PIR detectors. Product Guide. Overview. Features

SMART BASIC BASIC-IR DAYLIGHT

Operating instructions

Integrated PIR detectors

Premium Version Tri-level Dimming Control

OPERATING INSTRUCTIONS

Ceiling PIR presence detector DALI / DSI dimming. PIR Sensor. IR Receiver. Light Level Sensor. Status LEDs. PIR Sensor.

Ceiling PIR HS presence detector 1-10V, low temperature. PIR Sensor. IR Receiver. Light Level Sensor. Status LEDs. IR Receiver

Product Guide. Ceiling PIR HS presence detector DALI / DSI dimming. PIR Sensor. IR Receiver. Light Level Sensor. Status LEDs.

Data sheet. Function description. Benefits

1 Safety instructions. 2 Device components. Presence detector. Operating instructions

EBDHS-DD-LT30. Ceiling PIR HS presence detector DALI / DSI, low temperature. Product Guide. Overview. Features

Product Guide. Ceiling PIR presence detector DALI / DSI dimming. PIR Sensor. IR Receiver. Light Level Sensor. Status LEDs.

1. Basic safety information 3 2. Proper use 3

Connections, displays and operating elements C D E G H. Installing the control unit

0701 CO Light, HVAC, Monitoring, Brightness

Built-in HF Sensor for High Bay

Tebis application software

High bay PIR presence detector DALI / DSI dimming. PIR Sensor. IR Receiver. Light Level Sensor. Status LEDs. IR Receiver

UP 258E11 OPTISENS OFFICE

EBMHS (standard & slim-line PSU)

Detector switch - Dual Tech SCS

Introduction. Dimming Function MC003V (Standard Version) MC003V R (Reinforced Version)

Devices for Special Applications

Product and Applications Description

The two type sensors are innovative and active motion dimmable LED drivers or ballasts.

MWS5. Miniature Microwave Presence Detector (standalone) Product Guide. Overview. Features

KNX/EIB - Product database - Application description

Product Guide. Ceiling microwave presence detector DALI / DSI. Microwave Sensor. IR Receiver. Light Level Sensor. Status LEDs.

D-TECT Introduction. Connecting the Unit. Quick Installation. Multi Beam Alignment & Masking. Mounting the Unit

Ceiling PIR HS presence detector. Product Guide. Overview. Features

Tri-level Control Sensor

PRODUCT DATA AND INSTALLATION SHEET MWS5-SA STAND ALONE MINIATURE CEILING MOUNTED MICROWAVE PRESENCE DETECTOR

B.E.G. LUXOMAT KNX-OCCUPANCY DETECTOR

High bay PIR presence detector 1-10V dimming. PIR Sensor. IR Receiver. Light Level Sensor. Status LEDs. IR Receiver

System 2000 System 2000 presence detector Comfort top unit. 1 Safety instructions. 2 Device components

1. Product characteristics 4 2. Safety 5 3. Proper use 5 4. Operation 6

Lighting Control. Sensor Daylight 2. Daylight+Motion 3. Daylight+Motion+Control 4. Daylight+Motion+Control IP67 5

D-Tect 2 GJD300 Quad PIR Movement Detector

GE Lighting. Lighting Controls. DALI Digital Lighting Controls

North America Version / Dimming Function. Introduction

Daylight harvest function to regulate light output for maintaining required lux level

Sensors and Detectors

Ceiling Microwave presence detector - DALI / DSI 12-24V AC/DC. Microwave Sensor. IR Receiver. Light Level Sensor. Status LEDs.

3. Proper use. 4. Function. 1. Product characteristics. 2. Safety. Function description. Channel A light. Motion detector

User Manual 120/240/300 Outdoor Motion Detector

64.7 Ø85. (1) Sensor inset (2) Lens pluggable. (3) Protection cover (covers the high-voltage terminals). (4) Ceiling (drill hole Ø70mm).

1 Safety instructions. 2 Device components. Light Management Universal automatic switch m. Art.-No.: AS Operating instructions

Presence detector Komfort attachment Installation Instructions

LUX Hardwired - Installation Notes

3. Intended use. 4. Function. 1. Product characteristics. 2. Safety. Functional description. Channel A light. Motion detector

Description of the application programme for KNX occupancy detectors version 3.1

Direct Dim Microwave Presence/Absence Detector

Detailed operating instructions

False Ceiling HF Sensors

Motion detector themova P360 KNX UP WH themova P360 KNX UP GR

THE EVOLUTION OF CONTROL APP & CLOUD PORTAL

Passive infrared ceiling sensor

Tri-level Control HF Sensor

Motion Sensor. For Outdoor Use. Wall & ceiling mounted. Quick & Easy Installation 2 Channels

SWITCHLITE MRE DDM ADJ

e-sense move dali Manual

PresenceLight 180A-KNX.. PresenceLight 360A-KNX.. PresenceLight 180B-KNX.. PresenceLight 360B-KNX..

Product Guide. Ceiling microwave presence detector DALI / DSI. Microwave Sensor. IR Receiver. Light Level Sensor. Status LEDs.

Rev KNX Technical Reference Manual Busch Präsenz tech 6131/ /11-500

SENSA MRE DDM MR

Ceiling Microwave presence detector - DALI / DSI 12-24V AC/DC. Microwave Sensor. IR Receiver. Light Level Sensor. Status LEDs.

Detailed operating instructions

2. Safety. 4. Function

FSTR- Series Microwave Motion Sensor (MSSD) Dimming Function/Detachable Version for LED Tri-proof Light & LED Batten. Introduction

SCS motion sensors Surface/wall mounting - PIR

Movement controller comfort, Flush-mounted (Up) xx, xx

Analogue Dimming Microwave Presence/Absence Detector

Tri-level Control HF Sensor

PIR movement and presence detectors 10 A

IP65 High Bay Dual Sense Sensor

Loop out. Ambient daylight threshold

Integrated SensorDIM LED Driver Daylight Monitoring Version

ECO-IR 360C NT. Presence detector. Art. Nr Bedienungsanleitung 2. Notice d utilisation 22. Installation manual 42

luxcontrol lighting control system SWITCH sensors smartswitch HF 5DP f Automatic switching based on motion and light level

SWITCHLITE MRE SLD MAN SWITCHLITE MRE SLD IP55

Microwave Sensor. Basic Microwave Sensor. Energy Saving Motion Sensor. Introduction Features Technical Specification. 3 Dimensions

Automatic switch attachment Standard Installation Instructions

compact office 24V compact office 24V Lux

Transcription:

luxcontrol lighting control sstem ILD 5DPI 14f Compact control module with ambient light sensor and motion sensor Product description Compact dimensions for luminaire installation For up to 10 DSI or LI devices (max. 5 per output channel) 2 LI/DSI output channels with adjustable negative offset from channel 2 to channel 1 Ambient light sensor with motion detector Max. installation height 5 m Switch input for on/off switching and dimming Can be remote controlled Individual adjustment of the parameters with ILD Programmer or DSI-SMART Programmer 5-ear guarantee ILD 5DPI 14F È Wiring diagrams and installation examples, page 7 ILD 5DPI 14F Black ILD 5DPI 14F Black 1.8m www.tridonic.com 1

luxcontrol lighting control sstem ILD 5DPI 14f Compact control module with ambient light sensor and motion sensor Technical data Rated suppl voltage 220 240 V Mains frequenc 50 / 60 Hz Power 2 W Stand-b power 0.5 W Momentar-action switch input for dimming single Digital control line DSI/LI 2 Control output (devices) 10 Max. output cable length at 1.5 mm² 100 m Operating temperature 0... +60 C Storage temperature -25... +70 C Tpe of protection IP20 Max. casing temperature tc 75 C 120 110 30 21 30 16,4 44,4 12,8 2 Ø13,9 1,9 3 Ordering data Tpe Article number Mounting Packaging carton ILD 5DPI 14f 28001203 Luminaire installation 10 pc(s). ILD 5DPI 14f Black 28001529 Luminaire installation 10 pc(s). ILD 5DPI 14f Black 1.8m 28001528 Luminaire installation 10 pc(s). Specific technical data Tpe Light detection angle asmmetric Detection Light measurement at Illuminance (factor default) 2 Motion detection angle smmetric the sensor head 1 Max. cable length sensor ILD 5DPI 14f 60 10 500 lx 150 lx 84 0.8 m ILD 5DPI 14f Black 60 10 500 lx 150 lx 84 0.8 m ILD 5DPI 14f Black 1.8m 60 10 500 lx 150 lx 84 1.8 m 1 The measured value at the sensor head corresponds to approx. 15 to 2,000 lux on the surface measured. 2 The illuminance is set for a room defined b Tridonic. Depending on the actual room (reflectance) the measured illuminance ma deviate from this value. The illuminance should therefore be checked in the installation and adjusted if necessar. www.tridonic.com 2

luxcontrol lighting control sstem ACCES- SORIES REMOTECONTROL IR6 Product description Optional infra-red remote control Switching on and off (On/Off button) Dimming (Up/Down button) Activation of automatic lighting control Setting the threshold control point (Set button) Ordering data Tpe Article number Dimensions L x W x H Packaging carton REMOTECONTROL IR6 28000647 86.5 x 40.5 x 7.2 mm 500 pc(s). ACCES- SORIES ILD Programmer Product description Optional infra-red programming unit for ILD Setting of predefined discrete parameter values Programmable functions such as light level, time dela, P.I.R., bright-out, power up Ordering data Tpe Article number Packaging carton Weight per pc. ILD Programmer 28000257 210 pc(s). 0.31 kg www.tridonic.com 3

luxcontrol lighting control sstem ACCES- SORIES DSI SMART Programmer Product description Optional infra-red programming unit for DSI-SMART PTM or ILD 1 44 2,5 100 Settings can be read and modified Programmable functions such as light level, time dela, P.I.R., bright-out, power up 180 Ordering data Tpe Article number Packaging carton Weight per pc. DSI-SMART Programmer 28000843 1 pc(s). 0.35 kg 1 At version 2.30 for ILD. ACCES- SORIES 5DPI 14f Mounting Kit Product description Mounting frame for attaching all 5DP 14f sensor directl to the luminaire housing Shutter for preventing movement detection in one direction Ordering data Tpe Article number Packaging carton Weight per pc. 5DPI 14f mounting kit 28001558 100 pc(s). 0.004 kg 5DPI 14f mounting kit black 28001575 100 pc(s). 0.004 kg www.tridonic.com 4

luxcontrol lighting control sstem 1. Standards EN 55015 EN 61000-3-2 EN 61347-1 EN 61347-2-11 EN 61547 EN 62386-101 1.1 LI standard The ILD is designed to control control gear with LI standard IEC 60929 (LI V0) and IEC 62386 (LI V1). 1.2 Glow-wire test according to EN 61347-1 passed. 2. Common The basic DIM ILD provides the basis for an eas-to-use and cost-effective lighting sstem with motion detection. When the sensor detects movement it triggers a individual adjustable motion detection profile in the control unit. As the amount of natural ambient light changes the illuminance from the artificial lighting sstem is adjusted. The connected luminaires can be switched on and off via momentar-action switch or remote control possible. IR is alwas active. 3. Interfaces / communication 3.1 DSI/LI interface The interface selection DSI or LI is made b the DSI SMART Programmer. 3.2 Switch ILD has an input terminal for an external switch. An number of switches can be connected in parallel to the terminal. Short press (> 50 600 ms): Long press (> 600 ms): ON/OFF Dim up/down A change in the light value deactivates lighting regulation onl temporaril. As soon as the luminaire has been automaticall switched on again (motion detection) or manuall switched off and on again, regulation is activated again. 2 x short press: The overwritten setpoint light value is stored (luminaire acknowledges b flashing twice) Function is lockable via the DSI programmer www.tridonic.com 5

luxcontrol lighting control sstem 4. Installation Don t use the ILD without the sensor. DSI/LI is not SELV. The installation instructions for mains voltage therefore appl. The maximum cable length between the external switch and ILD is 100 m. The cable between the luminaire installation sensor and the base module must not be extended. A snchronous operation of LI and DSI ballasts at the same control gear is not possible. The maximum cable length of the DSI / LI control signal (for a cable cross-section of 1,5 m 2 ) must not be exceeded. An number of push to make switches ma be connected in parallel to the inputs. Do not connect standard switches to the input. Please ensure that the detection range of the sensor lies in the lighting area of the controlled luminaires. Please ensure that the detection ranges of the sensors do not overlap. This ma have influence to the lighting control. Heaters, fans, printers and copiers located in the detection zone ma cause incorrect presence detection. To avoid false readings, the sensor should be installed so there is no direct light from the lamp in the detection zone. To avoid false measurements caused b the light from other luminaires we recommend that the sensor should be located centrall in the luminaire. Sensor wires must be routed separatel from the lamp wires and mains cables otherwise the lighting control sstem ma malfunction. If separate routing is not possible (for reasons of space) shielded lamp wires and mains cables must be used. 4.1 Wiring diagram ILD L N 2 3 4 PCA 6 7 L N T ILD CH1 D1 D2 2 3 4 PCA Sensor CH2 D1 D2 6 7 ILD Sensor 4.2 Enhancement of controllable light point B using a combination of LI Repeater and LI Power Suppl it is possible to enhance the sum of controllable light points. The schematic visualizes the wiring. L N Max. 2 Max. 120 2 3 4 6 7 LCA N ~ L PS2 2 3 4 6 7 LCA L N T ILD CH1 D1 D2 Sensor CH2 D1 D2 IN LI Repeater OUT ILD Sensor Use onl in combination with LI Repeater (86458401) and one of the following LI Power Supplies: LI PS1 (24034323), 200 ma, max. 100 additional devices LI PS2 (28000876), 240 ma, max. 120 additional devices Wire length for 1.5 mm 2 cables: from to LI Repeater max. 100 m after LI Repeater max. 300 m This combination can be used on CH1 and CH2. www.tridonic.com 6

luxcontrol lighting control sstem 4.3 Cable tpes and cable cross-sections Solid wire with a cable cross-section of 0.5 mm² to 1.5 mm². wire preparation: 0.5 1.5 mm² 8 9 mm 4.4 Mounting variants luminair housing: Size of the sheet: 0.8 1.8 mm Size of the sheet: 0.6 0.8 mm 1,5 2,5 19,1 ø14,1 +0,2 0 2,2 +0,2 0 4 +0,2 0 20 +0,1-0,1 ø1,8 +0,1 0 3,2 0-0,15 Size of the sheet: 0.8 3.0 mm 3,3 5,5 41,1 +0,2 0 14,1 +0,2 0 R1,9 0-0,2 www.tridonic.com 7

luxcontrol lighting control sstem 4.5 Mounting in luminaire housing with Mounting Kit: Size of the sheet: 0.8 2.0 mm Dimension drawing for needed mounting opening 0,0 ø21,2 +0,1 R0,9 1,8±0,05 Shutter support ring has to be snapped into the shutter support Thickness metal sheet 0.8 2.0 mm 0.8 10,65±0,05 Option shutter: has to be snapped into the shutter support ring 4.6 Mounting Kit mounting 4.7 Mounting Kit Shutter Area which is masked b the shutter. 120 Masked area www.tridonic.com 8

luxcontrol lighting control sstem 4.8 Mounting in class II luminaire The Sensor provides basic insulation as required b IEC 62386-101 and defined in IEC 61347-1. If the sensor is built in to a class II luminaire which has to provide double or reinforced insulation it has to be considered that the Sensor is not a class II device. Still the Sensor can be used for such projects as the front of the sensor is tested to fulfill the class II requirements for double or reinforced insulation. Class II 5. Sensor functions 5.1 Light level recognition area Sensor alignment x2 h x2 x1 α x2 = 22 α x1 = 38 α = 30 22 38 x2 x1 h x1 h * x1 x2 d 1.7 m 1.3 m 0.7 m 1.0 m 3.0 m 2.0 m 1.6 m 0.8 m 1.2 m 3.6 m 2.3 m 1.8 m 0.9 m 1.3 m 4.1 m 2.5 m 2.0 m 1.0 m 1.4 m 4.5 m 2.7 m 2.1 m 1.1 m 1.6 m 4.9 m 3.0 m 2.3 m 1.2 m 1.7 m 5.4 m 3.5 m 2.7 m 1.4 m 2.0 m 6.3 m 4.0 m 3.1 m 1.6 m 2.3 m 7.2 m * The recommended maximum room height for office applications is 3 m and for corridor applications for example 4 m. Up to 2 m mounting height presence is detected and over 2 m motion is detected. Calculation of the diameter (light area): x1 = tan(ax1) h x2 = tan(ax2) h = tan(a) h Calculation of the diameter (motion area): d = 2 tan(0,5 a) h x2 x2 x1 x1 5.2 Presence / motion detection Example for light and motion detection area at height of 1.7 m: 1 m h α = 84 0.7 m x2 x1 1.3 m d Light level recognation area 1 m Presence / motion detection 3.0 m www.tridonic.com 9

luxcontrol lighting control sstem The following operating modes can be set for the motion detector via the ILD Programmer or DSI-Smart Programmer: Active Off Onl Never Off Inactive 5.3 Switch-off dela The light is switched on or off automaticall depending on whether or not there is a person in the room. The motion detector onl switches the connected lighting off. The luminaires are switched on manuall via the connected external switch or infra-red control. If it has not detected an movement the sensor dims to the second light value parameter and remains at this value The motion sensor is deactivated. The light must be switched on or off manuall. This is the time after which the lighting is switched off if no movement is detected. It can be set via the time dela parameter. 5.4 Second light value On the ILD ou can set whether the light is to be switched off after the switch-off dela or dimmed to the second light value. The light value and the dwell time (how long the value is held) can be set via the when vacant and sec. level parameters. 5.5 Offset The light level of channel 2 is less then the light level of channel 1. The difference can be set with the parameter Offset Value via ILD Programmer or DSI-SMART Programmer. Channel 2 Channel 1 40 % 70 % 5.6 Manual-off dela If the sstem is switched off manuall via the switch or remote control the motion sensor is deactivated. At the end of a 10 minutes dela if motion has not been detected the motion sensor is activated again. If the sensor detects motion during the Manual Off dela, the time will be reset to the start. The following operating modes can be set for lighting control via the DSI-Smart Programmer: Active Inactive Constant light control is active. Constant light control is deactivated. The lighting is switched on at 100%. The value is set with the light-level parameter. If the value is set to max then lighting control is deactivated. For all other values lighting control is active. 5.7 Setpoint adjustment DSI-SMART Controller: Pressing the Set button stores the current light value as a new setpoint. ILD Programmer or DSI-SMART Programmer: Via the light-level parameter External switch: Briefl pressing the switch twice stores the current light value as a new setpoint. (Function is lockable via the ILD Programmer or DSI Programmer) 5.8 Bright-out If the nominal illuminance (e.g. 500 lux) is exceeded for 10 minutes b more than 150 % (e.g. 750 lux), the lighting is switched off even if motion is detected. The lighting is switched on again when the measured light value falls below the setpoint. The bright-out function is displaed b a green status indication LED at the sensor. This function can be deactivated via the ILD Programmer or DSI-SMART Programmer. 500 LUX Artificial light Natural light www.tridonic.com 10

luxcontrol lighting control sstem 5.9 User-definable parameters ILD have the following user-definable parameters (since DSI-SMART Programmer version 2.30): The values in parentheses are the factor default settings. The adjustable values for the ILD Programmer is available in a separatel documentation on www.tridonic.com. Parameter light-level time dela if vacant Range (Factor setting) 1 100/max (70) 30 s 60 min/con (20 min) off 30 s 60 min/con (off) sec. level 1 100 % (1 %) P.I.R bright-out Power up hold overwrite PTM Set LIorDSI Offset Mode active/inactive/off onl (active) es/no (es) on/off (on) on/off (off) on/off (on) DSI/LI (DSI) fixed/converging (converging) Offset Value 0 to -70 % (-30 %) Description Selectable lighting control set point, 1 100 increments. max also makes it possible to set the control gear to full power. (DSI 255) man indicates whether the adjustment value was overwritten b the SET function of the SMART Controller. Dela time after the last detected movement The following values can be set: 30 seconds, 1, 2, 3, 5, 10, 15, 20, 30, 45 and 60 minutes and continuous (no switch-off) The off setting switches the luminaire off after the dela time has elapsed. If a time value is set, the luminaire dims to the sec. level parameter and onl switches off after the previousl set time has elapsed. The following values can be set: off, 30 seconds, 1, 2, 3, 5, 10, 15, 20, 30, 45 and 60 minutes and continuous ( never OFF function) Second light level to which luminaire dims after the dela time has elapsed. (in conjunction with the if vacant parameter) With the active setting, the lighting is automaticall switched on or off depending whether a person is present. With the inactive setting, the ILD/DSI-SMART (PTM) can, in combination with continuous time dela, onl be used for lighting control. With the off onl setting, the lighting has to be switched on manuall (momentar-action switch, remote control) but is switched off b the presence detector. With the es setting, the lighting switches off as soon as the light level exceeds 150 % of the set point for longer than 10 minutes, for instance, if the room is adequatel illuminated b sunlight. If the actual value falls below 100 % of the set point, the lighting switches back on again. With the no setting, the lighting remains switched on (at the minimum dimming level) even if the room is adequatel illuminated b sunlight and no artificial lighting is required. With the on setting, the luminaire switches on after a mains break. With the off setting, the luminaire does not switch on after a mains break. The presence detector becomes active again after 15 seconds. If the light level is manuall dimmed via a momentar-action switch or remote control, lighting control stops. The previousl set dimming level retains its fixed value as long as lighting control is not activated b manual intervention (momentar-action switch or remote control). If there is no movement in the room in this state and the time dela has elapsed, the control unit stores the fixed dimming level. With the off setting, lighting control is restarted each time movement is detected. With the on setting, the control unit switches the luminaires back to the fixed dimming level each time movement is detected and lighting control remains stopped. With this setting, lighting control can be activated again via the remote control (Automatic button). If lighting control was active before repeated detection or if the lighting was switched off manuall, the luminaires and lighting control are switched on after movement is detected in order to prevent people having to enter a dark room. With the on setting, it is possible to save the currentl set light level as a lighting control set point b pressing the momentar-action switch twice shortl. With the off setting, this function is disabled. With the DSI setting, DSI interface mode is enabled. With the LI setting, LI interface mode in which LI broadcast commands are sent is enabled. This parameter specifies how the adjustable Offset Value of the ILD behaves from channel 2 to channel 1 over the dimming range. With the fixed setting, the previousl set Offset Value remains the same across the dimming range. (e.g. with an Offset Value of -30 %, channel 2 remains at 70 % when channel 1 has reached 100 %). With the converging setting, the previousl set Offset Value remains the same up to a specific dimming level and decreases the closer one gets to 100%. (e.g., with an Offset Value of -30 %, the dimming level of channel 2 is 40 % and that of channel 1 is 70 %. but both channels simultaneousl change to a dimming level of 100 % if the lighting is dimmed up). Adjustable brightness difference between channel 2 and channel 1 of the ILD. The following values can be set: 0 %, -10 %, -20 %, -30 %, -40 %, -50 %, -60 % and -70 % www.tridonic.com 11

luxcontrol lighting control sstem 5.10 Default Parameter Motion Detector Parameter A light-level 1 time dela B sec. level 2 if vacant 6. Miscellaneous 6.1 Additional information Additional technical information at www.tridonic.com Technical Data Guarantee conditions at www.tridonic.com Services Life-time declarations are informative and represent no warrant claim. No warrant if device was opened. www.tridonic.com 12