PRE-INSTALLATION GUIDE for MODELS

Similar documents
PRE-INSTALLATION GUIDE for MODELS

PRE-INSTALLATION GUIDE

PRE-INSTALLATION GUIDE

PRE-INSTALLATION GUIDE

PRE-INSTALLATION GUIDE

DENTAL VACUUM SYSTEM Part Numbers: VS2O, VS40, VS50, VS50H, VS80 and VS80H RECOMMEND DAILY USE OF MONARCH CLEANSTREAM USER S MANUAL

DENTAL AIR SYSTEM. AS12, AS22, AS50 AS70, AS12C, AS22C & AS50C International. Installation and Operation Manual

User s and Installation Manual

AirStar Clinical Air Compressor AS60, AS90 and AS120. Installation & Operating Instructions

Installation & Operation

Utility Room Accessories. Take your equipment s performance to the next level.

Va c S t a r V a c S t a r N e o. More Performance. Less Water. Less Energy.

Equipment Alert. P-Trap Must Be Installed to Exhaust or Warranty will be Voided. Refer to this Manual for installation Instructions

Dansereau Dental. P r e - C o n s t r u c t i o n G u i d e

Vacuum Plumbing Layout Recommendations

A m e r i c a s D e n t a l E q u i p m e n t C o m p a n y. Rev 2/15. D a n s e r e a u

PowerVac G Single to Twin Conversion Kit [ ]

Oil-Free Air Compressors. Membrane Dryer Technology.

WineZone Ceiling Mount Ductless Split 15

Quest 105, Dry155, and 205 Dual

USER MANUAL/Installation Instructions LRV-4

Installation Guide. 15 W. Undercounter/Freestanding Nugget Ice Machine U L. Viking Range, LLC. 111 Front Street

Quest Dry 105, 155, and 205 Dual

Clinical Solutions. The Technological Advantage for

Read Only Document Not For Distribution

Installation Manual CARBONATOR With Plain-Water Booster

Special Requirements For Health Care Facilities

INSTALLATION MANUAL. Manufactured by AQUA-AIR MANUFACTURING. (801) or (800) FAX (801)

INTRA-ORAL FILM PROCESSOR USER S MANUAL

Installation. 15 W. Undercounter/Freestanding Ice Machine FGIM515 / CFGIM515 FPIM515 / CFPIM515

WKS 2200 SERIES (USA only) --INSTALLATION INSTRUCTIONS--

HUMIDITY SENSING BATH FAN

VENTILATION FAN / LED LIGHT

RP, GP, XP Pro Series Installation Instructions

ENSPECO Recovery/ Recycle/ Evacuate/ Recharge

VENTILATION FAN READ AND SAVE THESE INSTRUCTIONS MODEL 50F / 70F / 70HS TABLE OF CONTENTS. Package Contents 2. General Safety Information 3

Installation Instructions Remote Blowers

Essential Utilities. Your practice depends on dental compressed air and vacuum. AirStar. STS. VacStar. Steadfast reliability for your peace of mind.

Mojave. Superior Performance. Energy Efficiency. All In A Singular Dry Vacuum.

Model 1820 Dehumidifier

Air-Cooled Condenser. Installation Instructions. Revision Date: 12/21/98

VENTILATION FAN / LED LIGHT / LED NIGHT LIGHT

DRY 150 Quest PowerDry 1300

VENTILATION FAN READ AND SAVE THESE INSTRUCTIONS. MODEL Pro200/Pro300 TABLE OF CONTENTS. Package Contents. General Safety Information

Installation Instructions. Revision Date: 05/16/12

MODELS B1PA024, 030 AND 036

VetPro Solo Installation

Viking Installation Guide

Quest CDG Dry 74. Read and Save These Instructions. Installation, Operation and Maintenance Instructions

CENTRAL AIR CONDITIONER SPLIT SYSTEM

OPERATION & MAINTENANCE MANUAL TX600

Installation Instructions. For the 18 Built-In Dishwasher and Front Color Panels

B.C.S. Shop Heaters 26, 30 & 36 (36 shown)

ELECTRIC COOKTOP INSTALLATION INSTRUCTIONS

COMBUSTION AIR SYSTEM

APPUZO RANGE HOOD INSTALLATION

INSTALLATION INSTRUCTIONS

ELECTRIC COOKTOP INSTALLATION INSTRUCTIONS

Installation. 324 Series Built-In Dishwashers U L. Viking Range, LLC 111 Front Street Greenwood, Mississippi USA (662)

Truck Edition V-220 / V-320 Series Single Temperature Systems TK IM (Rev. 0, 06/17)

Safety and Installation Instructions Model 1700

Introduction to Supermarket Vacuum Condensate Drainage Systems by AcornVac, Inc.

Model LF-310 Air Operated

Nominal Circuit Capacities: 9,000 12,000 18,000 & 24,000 Btuh units.

Decon Scrubber Owner s Manual

INSTALLATION INSTRUCTIONS UNDERCOUNTER DISHWASHERS

IMPORTANT INSTRUCTIONS READ & SAVE

APPLICATION DATA SHEET

Horizon Elite Ice Machine Installation Instructions for Remote Condensing Unit

STERI-VAC CENTRAL SUCTION SYSTEM

BATH FAN / LED LIGHT READ AND SAVE THESE INSTRUCTIONS MODEL GBR100LED-DECOR TABLE OF CONTENTS. Package Contents 2. General Safety Information 3

Integrated Ventilation System

IMPORTANT INSTRUCTIONS READ & SAVE

Horizon Ice Machine Installation Instructions to Ice Storage Bin Top-mount Applications

SF180 Installation Instructions

Installation Instructions

VENTILATION FAN. MFG Model : VFB80HLED2/VFB080C4L2 /VFB080C4LED2/ VFB100HLED2/VFB100C4LED1 READ AND SAVE THESE INSTRUCTIONS

RP / RPc Series Installation Instructions

HS Series Installation & Operating Instructions RadonAway

Gerber Innovations M Series Laser. Site Preparation & Installation Manual

Sundance Spas SPA EQUIPMENT SYSTEM. Installation Instructions. P/N Rev. A

INSTALLATION and OPERATION INSTRUCTIONS

Installation Instructions

Quest Dry. Quest 110 Dual. Read and Save These Instructions. Installation, Operation and Maintenance Instructions

HS Series Installation & Operating Instructions RadonAway

IN020 Rev F Page 1 of 8

INSTRUCTIONS! DO NOT DISCARD!

VENTILATION FAN WITH LED LIGHT AND HEATER MODEL RAD110LED

Flood Pumper Plus. Water Transfer Machine. Operator and Parts Manual. Model No.: Rev. 00 (11-99)

Unit Data - RCA 051 RATED IN ACCORDANCE TO AHRI STANDARD

INSTALLATION INSTRUCTIONS TD75. Vented tumble dryer DOMESTIC. Carefully read the instructions for use before using the dryer.

Installation Plan. Professional Dishwasher PG Mat. no.: en - US

INSTRUCTIONS! DO NOT DISCARD!

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS. HA300, HB360, HB480 & HB thru 50 NOMINAL TONS (50 Hz)

CONTENTS CONSIDERATIONS. General Plumbing Component Connection ILLUSTRATION. Control System CONFIGURATION. Voltage Verification CONNECTION

Installation Instructions

347002K/177002K/34900

Site Specifications for the. INDUSTREX M37 Plus NDT Filmprocessor

Installation Instructions

R-2000 HEADLINER Air Conditioner Unit

Transcription:

DENTAL VACUUM SYSTEMS PRE-INSTALLATION GUIDE for MODELS VS20NEO & VS40NEO Check VacStar NEO Model Being Installed: VS20NEO VS40NEO Model VS20NEO Model VS40NEO Doctor: Address: Phone#: Dealer: Dealer Address: PRODUCT SPECIFICATIONS Electrical Model VS20NEO Model VS40NEO Voltage Rating 220 220 Voltage Min./Max. 198/242 198/242 Full Load Amps 10 14 Frequency (Hz) 50/60 50/60 Water Inlet Water Pressure (PSI) 20-100 20-100 Flow Rate (gal/min) per Pump 0.13 0.13 Inlet Water Temperature ( F) 40-75 40-75 Vacuum Level Preset at Factory (in Hg) 10 10 All installations must conform to local codes.

PHYSICAL CHARACTERISTICS Model VS20NEO Model VS20NEO Height 19 inches (48 cm) Height 19 inches (48 cm) Width 11 inches (28 cm) Width 11 inches (28 cm) Depth 11 inches (28 cm) Depth 11 inches (28 cm) 11 in. 11 in. 11 in. 11 in. 19 in. 19 in. ELECTRICAL CONNECTIONS 220VAC Connections: Shipping Weight Shipping Weight 75 lbs. (34 kg) 75 lbs. (34 kg) Each pump has its own 6-foot BX cable pre-wired to the electrical connection box for direct wiring to dedicated 220VAC, single phase 50/60 Hz circuit via a disconnect box with approved ground. Disconnect box should be mounted no more than 3 feet of each other and 3 feet of installation center line. The supplied cable is pre-wired in the electrical box of each pump. Connect cable wires by matching color. Important: When not connecting a 24VDC remote switch, the ORG and YEL wires must be tied together and the BRN wire insulated for pump operation. 24VDC Connections: 24VDC Connections are used when installing a 24VDC remote switch. They are made via a supplied interconnect cable that is also pre-wired to the electrical connection box of each pump. Make the 24VDC connections shown below for the remote switch. When not using the remote switch, insulate the BRN wire and tie the ORG and YEL wires together. Supplied 6-Foot BX Cable from the Electrical Connection Box of Each Pump 220VAC Connections Green Yellow Stripe Black White Remote Switch Terminal Board BRN ORN YEL Interconnect Cable BRN Interconnect Cable ORN Interconnect Cable YEL 24VDC Connections GRN Remote Switch 2 Yel 3 Org 4 Brn Connection without 24VDC Switch CLASSIFIED MEDICAL ELECTRICAL EQUIPMENT WITH RESPECT TO ELECTRICAL SHOCK, FIRE, MECHANICAL AND OTHER SPECIFIED HAZARDS ONLY IN ACCORDANCE WITH UL-60601-1, CAN/CSA C22.2 NO.601.1 66CA

UTILITY ROOM CONFIGURATION VacStar NEO without Wall-Mounted Air/Water Separator Buck/Boost Transformer (Optional) All VacStar NEOs are hard-wired directly to the VacStar s electrical box via a 4-inch handy box complying with local electrical codes. The 4-inch handy box is not supplied. IMPORTANT Add service disconnect if Power Supply Panel is not located in equipment room. Intake hose is part of the total supplied 8 foot hose shared between inlet and drain. Terminate with 3/4 inch FNPT fitting. Water Supply 1/2 inch copper tube terminate with 1/2 inch FNPT shut-off valve Building Power Supply Panel (Should be located in equipment room.) from Exhaust Drain Connector In-Line Muffler to Facility Drain Connector Drain hose is part of the total supplied 8 foot hose shared between inlet and drain. Floor Drain 1 / 4 inch Poly Tubing 6 feet supplied See Optional Drain Connections VacStar NEO with Wall-Mounted Air/Water Separator IMPORTANT Add service disconnect if Power Supply Panel is not located in equipment room. Buck/Boost Transformer (Optional) All VacStar NEOs are hard-wired directly to the VacStar s electrical box via a 4-inch handy box complying with local electrical codes. The 4-inch handy box is not supplied. WARNING: Condensation of Water will occur in vent piping. Avoid Accumulation of water in vent. Slope piping toward separator. Vent vent to outside with 2 schedule 40 pipe Intake hose is part of the total supplied 8 foot hose shared between inlet and drain. Terminate with 3/4 inch FNPT fitting. 18 Inches Maximum Building Power Supply Panel (Should be located in equipment room.) Air/Water Separator 32 Inches Maximum. Drain hose is part of the total supplied 8 foot hose shared between inlet and drain via Air/ Water Separator Water Supply 1/2 inch copper tube terminate with 1/2 inch FNPT shut-off valve 1 / 4 inch Poly Tubing 6 feet supplied In-Line Muffler Floor Drain See Optional Drain Connections All VacStar NEO vacuums comply with NFPA 99C level 3 requirements

PLUMBING INSTALLATION SUB FLOOR INSTALLATION - The sub-floor plumbing layout shown below is the recommended layout for VacStar system installations and should be used whenever possible. 45 Elbow Main Line Interior Wall From Dental Unit 1/2 Inch Riser 1/2-Inch Diameter Riser 45 Y To Pump RISER to MAIN LINE DETAIL Junction Box Ceiling Minumum Slope: 1/4 inch per 10 Feet from Exhaust Drain Connector MAIN LINE See Plumbing Requirements for Main Line Diameters needed for specific units. See Notes 3, through 6. In-Line Muffler to Facility Drain Connector Floor Drain See Note 1 Riser - See Note 2 Notes: 1. See Optional Drain Connections shown below. 2. 8-Foot Maximum Height from Main Line to pump. 3. Consult Dental Unit Manufacturer's Guidelines for correct reduced size and height of termination of vacuum line inside junction box. 4. Limit branches. Orient main line under junction box or cabinet. 5. When main line is 1-1/2" I.D. or larger, use 45 Y's and elbows only. 6. Long radius 90 elbows can be used as alternates to 45 elbows. 7. A total of 8 feet of 3/4 inch hose is supplied with VacStar units. This hose must be shared between inlet and drain. OVERHEAD INSTALLATION - The overhead plumbing layout shown below is the alternate layout for VacStar system installations and should be used only when unable to use the sub-floor plumbing layout. MAIN LINE See Plumbing Requirements for Main Line Diameters needed for specific units. 45 Elbow 1" Min Main Line 45 Elbow 1/2 Inch Riser 1/2 Inch Diameter 45 Y To STS Pump Minumum Slope: 1/4 inch per 10 Feet RISER to MAIN LINE DETAIL 1/2-Inch Riser To Main Line Dental Unit Interior Wall 1/2-Inch Diameter Riser 10-Foot Maximum Height from Riser Trap to Main Line Junction Box Ceiling from Exhaust Drain Connector In-Line Muffler to Facility Drain Connector Floor Drain 1/2-Inch RISER TRAP DETAIL (Using 45 Elbows) Consult Dental Unit Manufacturer's Guidelines for correct reduced size and height of termination of vacuum line inside junction box. See Optional Drain Connections CONNECTION DETAILS ALL INSTALLATIONS - 45 Elbow CLEARING AN OBSTRUCTION MAKING TURNS 45 Elbow MAIN LINE O Use only 45 elbows or sweeping (sanitary) 90 elbows to make turns in main line. O If piping is diverted to clear an obstruction, DO NOT MAKE A TRAP. DRAIN OPTIONS Direct connection to vented drain. No traps before vent. CLOSED VENTED DRAIN OR Indirect connection (Air gap) with a p-trap. 6 1-1/2 Inch P-Trap OPEN DRAIN PIPE All installations must conform to local codes.

SITE REQUIREMENTS Electrical VS20NEO VS40NEO Minimum Panel Breaker Rating 15A 20A Minimum Wire Gauge Size 14 AWG 12 AWG 220-Volt Buck/Boost Transformer #67002 (3.4 KVA) #67002 (3.4 KVA) Plumbing Suction piping must slope at least a ¼ for each 10 feet of run towards the pump. Use PVC Schedule 40 or Copper Type M. Minimum CFM @ 0" Hg 15 20 Air Exhaust with Air/Water Separator 2" schedule 40 pipe 2" schedule 40 pipe Overhead Plumbing Main Line Diameter (Min./Max. ID in inches) 1 to 1½" 1¼ to 2" End Fitting 3 /4 FNPT 3 /4 FNPT Overhead Main Line ½" ID ½" ID Floor Plumbing Main Line Diameter (Min./Max. ID in inches) 1 to 1½" 1¼ to 2" End Fitting 3 /4 FNPT 3 /4 FNPT Branch Line Diameter (Min./Max. ID in inches) 3 /4 to 1½ 1 to 1½ Environmental Ambient Temperature (See ventilation requirements below.) 40 to 104 F (5 to 40 C) 40 to 104 F (5 to 40 C) Equipment Room Temperature The VacStar NEO equipment must be used in a controlled temperature environment. Maintain equipment room temperature between 40 and 105 degrees Fahrenheit. Adequate forced ventilation must be provided across the unit by placing an appropriate exhaust fan opposite an equivalent air intake vent. The fan should be higher than the associated intake vent. Exhaust Vent Protection. VENTILATION REQUIREMENTS If the exhaust piping is venting to the outside of the building, precautions must be taken to protect the equipment room from weather elements and animal intrusion. This can be accomplished by using one of the three methods shown below. Shroud & Screen Screen Shroud & Screen Roof-Mounted Outside Vent Protection Wall-Mounted Outside Vent Protection Make sure to use the required pipe type for associated system

NOTES

NOTES

For over 50 years, Air Techniques has been a leading innovator and manufacturer of dental products. Our priority is ensuring complete satisfaction by manufacturing reliable products and providing excellent customer and technical support. Whether the need is digital imaging, utility room equipment or merchandise, Air Techniques can provide the solution via our network of authorized professional dealers. Proudly designed, tested and manufactured in the U.S., our products are helping dental professionals take their practices to the next level. Air Techniques family of quality products for the dental professional include: Digital Imaging Digital Radiography Intraoral Camera Caries Detection Aid Intraoral X-ray Panoramic X-ray Film Processors Utility Room Dry Vacuums Wet Vacuums Air Compressors Amalgam Separator Utility Accessories Utility Packages Merchandise Surface Disinfectant Enzymatic Cleaner Hand Sanitizer and Lotion Waterline Cleaner Evacuation System Cleaner Imaging Accessories Chemistry Processor Accessories Corporate Headquarters 1295 Walt Whitman Road Melville, New York 11747-3062 Phone: 800-247-8324 Fax: 888-247-8481 Western Facility 291 Bonnie Lane, Suite 101 Corona, CA 92880-2804 Phone: 800-247-8324 Fax: 951-898-7646 www.airtechniques.com VacStar is a registered trademark of Air Techniques, Inc. Air Techniques, Inc. P/N K1105 Rev. A March 2016