USERS GUIDE. LOGIC+ Combi 24, 30, 35

Similar documents
Logic+ Combi

USERS GUIDE 24, 30. For installation guide see reverse of book

USER GUIDE VOGUE COMBI GEN2 C26 C32 C40

USERS GUIDE. Esprit eco 24, 30. For installation guide see reverse of book

Combi C30 & C35. User Guide FAN POWERED HIGH EFFICIENCY MODULATING DOMESTIC CONDENSING GAS COMBINATION BOILER

i 24, i 30, i 35 combination boilers USER GUIDE For Installation Guide see reverse of book UIN A05 October 2017

USER GUIDE VOGUE MAX SYSTEM

System s30. User Guide FAN POWERED HIGH EFFICIENCY MODULATING DOMESTIC CONDENSING GAS SYSTEM BOILER

USER GUIDE LOGIC HEAT H

Heat 45 & 55. User Instructions FAN POWERED HIGH EFFICIENCY MODULATING DOMESTIC CONDENSING GAS COMBINATION BOILER

USER GUIDE. IMAX XTRA EL kW. For Installation Guide see reverse of book

GB24 & GB30. User Manual

2 Minimiser SE - User's

WARMCAIR. Condensing Air & Water Heater. High Efficiency Downflow Condensing Air & Water Heater USERS INSTRUCTIONS

USERS GUIDE. Electronic Timer, 7 day. LOGIC+ Combi, LOGIC Combi & LOGIC Combi E 24, 30, 35

RF ELECTRONIC PROGRAMMABLE ROOM THERMOSTAT, 7 DAY

Open Vented Condensing Boilers

Baxi Maxflow Combi FS

Ultracom cxi. Instructions for Use. High Efficiency Condensing System Boilers. To b e l e f t w i t h t h e u s e r.

USER INSTRUCTIONS & CUSTOMER CARE GUIDE Si II SERIES

User's Instructions. Alpha CB50

Maximiser SE. USER S INSTRUCTIONS Natural gas only INSTALLER: TELEPHONE:

Baxi System 100 HE Plus. User s Operating Instructions. Wall Mounted Powered Flue Condensing Gas Fired Central Heating Boiler

Baxi Maxflow Combi WM

User's Instructions. Alpha CD24C/32C. Range of Wall Mounted, Fan Assisted, Room Sealed, Gas Fired, High Efficiency Condensing Combination Boilers

User's Instructions. Alpha CD25X/28X. Range of Wall Mounted, Fan Assisted, Room Sealed, Gas Fired, High Efficiency Condensing Combination Boilers

Ultracom hxi. Instructions for Use. High Efficiency Condensing System Boilers. To b e l e f t w i t h t h e u s e r.

Baxi Combi 133 HE Plus Baxi Combi 100 HE Plus Baxi Combi 80 HE Plus. User s Operating Instructions

British Gas 330+ High Efficiency Condensing Boiler. Instructions for Use. To b e l e f t w i t h t h e u s e r. British Gas Service Tel:

User Guide and Important Warranty Information. Suprima HE. Condensing Central Heating Boiler. Please read this document and keep it safe.

PLEASE LEAVE THIS INSTRUCTION WITH THE USER. Ecomfort 30 HE. User instructions

O. Gas boiler. Gaz 6000 W WBN H-E-N/L-S2400. Operating instructions for the end customer (2017/09) en

The guarantee on this appliance is valid for 12 months from the first day of installation.

24CDi, 28CDi & 35CDi II COMBI

Powermax HE 85, 115 & 150 Litre Condensing Boilers with Integrated Hot Water Storage

PLEASE LEAVE THIS INSTRUCTION WITH THE USER ECOMFORT PLUS 25 HE. User instructions

Format System 25 HE. User instructions. Please read the Important Notice within this guide regarding your boiler warranty

Ultracom 2. sxi. Instructions for Use. 12sxi. 18sxi. 30sxi. High Efficiency Condensing System Boilers. To be left with the user. G.C. No.

Greenstar 25Si/30Si USER INSTRUCTIONS & CUSTOMER CARE GUIDE

condens Instructions for Use Betacom 2 24 G.C. No Betacom 2 28 G.C. No

Baxi Bahama 100. Gas Fired Wall Mounted Combination Boiler. User s Operating Instructions

FORMAT DGT HE. User instructions. Please read the Important Notice within this guide regarding your boiler warranty

Osprey 2 CFL

iheat 25c iheat 30c iheat 35c

With a power output ranging from 13kW to 24kW, they provide the flexible answer for the majority of traditional installation scenarios.

Performa 24. Gas Fired Wall Mounted Combination Boiler. User s Operating Instructions

USER INSTRUCTIONS & CUSTOMER CARE GUIDE HIGHFLOW 400 ELECTRONIC SERIES

Baxi Combi 80Eco. Gas Fired Wall Mounted Combination Boiler. User s Operating Instructions

Greenstar 12i/24i System

MURELLE EV HE 25/55-30/55

Vote for your Installer of the year at. 9/14, 14/19 & 19/24CBi. Worcester supports the Benchmark code of practice

Vote for your Installer of the year at HEATSLAVE

Combi Eco Elite Range. User s Guide and Important Warranty Information

Users Manual. Gas wall hung Boiler condensing Buderus /S. Please read thoroughly before operating the unit

Operating instructions

VIESMANN. Operating instructions VITODENS 100-W. for the system user

VIESMANN. Operating instructions VITODENS VITOPEND. for the system user. Heating system with Vitotronic 100 control unit for constant temperature mode

GREENSTAR HIGHFLOW 440/550CDi

Operating instructions

MERIDIAN HE 30 C. User instructions. Please read the Important Notice within this guide regarding your boiler warranty

VIESMANN. Operating instructions VITODENS 100. for system users. Heating system with control unit for constant temperature operation

VIESMANN. Operating instructions VITODENS 111-W. for the system user

Mikrofill Ethos Condensing combination boiler. Maintenance Instructions 24cc

Statesman 45/50L, 50/70L, 70/90L, 90/110L, Utility 50/70L, 70/90L, 90/110L, 110/130L, 130/150L

Ideal Boiler Error Codes L8

Operating instructions

/2005 GB(EN) For the user. Wall-mounted condensing gas combi boiler Buderus /C, /C

Grant Vortex. Boiler House Floor Standing Condensing Oil Boiler Range User Handbook. Model shown: VTXBH3646

condens Instructions for Use Ultracom 2 35 Store G.C. No

FEB-24E UK SUPERCOMPACT COMBINATION BOILER USER MANUAL

Linea HE. High efficiency combi boiler. Users Instructions THESE INSTRUCTIONS TO BE RETAINED BY USER

DANESMOOR 12-14, 15-19, 20-25, 26-32, 32-50, FLOOR-STANDING OIL-FIRED PRESSURE-JET BOILERS USER INSTRUCTIONS & CUSTOMER CARE GUIDE

DOMESTIC HOT WATER Follow operational sequence

GREENSTAR HIGHFLOW 440/550CDi

BOSCH CONDENS 5000W ZSB18-2A

Baxi Megaflo System HE IE Range. User s Operating Instructions & Important Warranty Information. Gas Fired Wall Mounted Condensing Boiler

AquaNova. Water heater. Users Instructions THESE INSTRUCTIONS TO BE RETAINED BY USER

Baxi Combi 105 HE. User s Operating Instructions. Gas Fired Wall Mounted Condensing Boiler

Users manual. Buderus /29/43/60 and Buderus T25/29T25 H/V. Wall-mounted condensing gas boiler. For the user

User Guide. Main Eco Elite Combi Condensing Central Heating Boiler

For the owner. Operating manual. ecotec plus 937. Gas condensing storage combination boiler VUI

Greenstar 12i system / 24i system

DANESMOOR FRONT SERVICE (FS) 12-18, FLOOR-STANDING OIL-FIRED PRESSURE-JET BOILERS USER INSTRUCTIONS & CUSTOMER CARE GUIDE

User s Information Manual

User Manual FLOWMAX-90. for model. Condensing water heater 85,000 BTU. Installation, operating, commissioning and maintenance instructions.

User Manual RBS 24. for model CE series ENERGY. Wall mounted instantaneous combi boiler room sealed chamber

User Manual for model

End User Manual ACO 35 MFFI COMBI

/2010 US/CA

WEATHER COMPENSATION KIT

Residential Gas Condensing Boiler Greenstar ZBR16/21/28/35/42-3A... ZWB28/35/42-3A...

Residential Gas Condensing Boiler Greenstar combi 100 p / 151 p ZWB28-3A... ZWB42-3A...

24/30/38. E-Combi. CONDENSING WALL HUNG COMBINATION BOILER G.C.N : (24 kw) G.C.N : (30 kw) G.C.N : (38 kw)

User Guide and Important Warranty Information. Promax System HE Plus A Range. Condensing System Boiler

Mikrofill Ethos Condensing combination boiler

User Guide. Platinum Combi Gas Fired Wall Mounted Condensing Combination Boiler

ir-range 8G /03.15 Changes reserved.

User Manual for model

Performa 24 Eco HE. User Guide and Important Warranty Information. Condensing Combination Boiler

User s Operation Instructions & Important Warranty Information

Transcription:

USERS GUIDE LOGIC+ Combi 24, 30, 35 When replacing any part on this appliance, use only spare parts that you can be assured conform to the safety and performance specification that we require. Do not use reconditioned or copy parts that have not been clearly authorised by Ideal.

2

IDEAL LOGIC + COMBI 24, 30, 35 (Natural Gas Only) Destination Countries: GB, IE 24 G.C. Appliance No. 47-348-65 30 G.C. Appliance No. 47-348-66 35 G.C. Appliance No. 47-348-67 Ideal Stelrad Group is a member of the Benchmark scheme and fully supports the aims of the programme. Benchmark has been introduced to improve the standards of installation and commissioning of central heating systems in the UK and to encourage the regular servicing of all central heating systems to ensure safety and efficiency. THE BENCHMARK SERVICE INTERVAL RECORD MUST BE COMPLETED AFTER EACH SERVICE 3

FOR ANY QUERIES PLEASE RING THE IDEAL CONSUMER HELPLINE : 01482 498660 NOTE. BOILER RESET PROCEDURE - To reset boiler, turn mode knob to reset position and immediately turn knob back to required setting. The boiler will repeat the ignition sequence. INTRODUCTION The Logic + Combi is a wall mounted, room sealed, condensing combination boiler, featuring full sequence automatic spark ignition and fan assisted combustion. Due to the high efficiency of the boiler, condensate is produced from the flue gases and this is drained to a suitable disposal point through a plastic waste pipe at the base of the boiler. A condensate 'plume' will also be visible at the flue terminal. The Logic + Combi is a combination boiler providing both central heating and instantaneous domestic hot water. SAFETY Current Gas Safety (Installation & Use) Regulations or rules in force. In your own interest, and that of safety, it is the law that this boiler must be installed by a Gas Safe Registered Engineer, in accordance with the above regulations. In IE, the installation must be carried out by a Registered Gas Installer (RGII) and installed in accordance with the current edition of I.S. 813 Domestic Gas Installations, the current Building Regulations and reference should be made to the current ETCI rules for electrical installation. It is essential that the instructions in this booklet are strictly followed, for safe and economical operation of the boiler. 4

ELECTRICITY SUPPLY This appliance must be earthed. Supply: 230 V ~ 50 Hz. The fusing should be 3A. Important Notes This appliance must not be operated without the casing correctly fitted and forming an adequate seal. If the boiler is installed in a compartment then the compartment MUST NOT be used for storage purposes. If it is known or suspected that a fault exists on the boiler then it MUST NOT BE USED until the fault has been corrected by a Gas Safe Registered Engineer or in IE a Registered Gas Installer (RGII). Under NO circumstances should any of the sealed components on this appliance be used incorrectly or tampered with. This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instructions concerning use of the appliance by a person responsible for their safety. Children should be supervised to ensure that they do not play with the appliance. In cases of repeated or continuous shutdown a Gas Safe Registered Engineer or in IE a Registered Gas Installer (RGII) should be called to investigate and rectify the condition causing this and carry out an operational test. Only the manufacturers original parts should be used for replacement. MINIMUM CLEARANCES Clearances of 165mm (6 1/2") above, 100mm (4") below, 2.5mm (1/8") at the sides and 450mm (17 3/4") at the front of the boiler casing must be allowed for servicing. Bottom clearance Bottom clearance after installation can be reduced to 5mm. This must be obtained with an easily removable panel, to enable the consumer to view the system pressure gauge, and to provide the 100mm clearance required for servicing. 5

BOILER CONTROLS LEGEND A. Pre-heat On/off B. DHW temperature control C. CH temperature control D. Mode Control E. Boiler Status F. Burner on indicator G. Pressure Gauge H. Condensate Drain J. Economy Mode A B E F C J D G H 6

TO LIGHT THE BOILER. (REFER TO BOILER CONTROLS) If a programmer is fitted refer to separate instructions for the programmer before continuing. 1. Check that the electricity supply to the boiler is off. 2. Set the mains Off/Summer/Winter control (D) to Off. 3. Set the Domestic Hot Water temperature control (B) and Central Heating temperature control (C) to max. 4. Set the preheat control (A) to on. 5. Ensure that all hot water taps are turned off. 6. Switch ON electricity to the boiler and check that all external controls, e.g. programmer and room thermostat, are ON. 7. Set the Off/Summer/Winter control to winter ( ). The boiler will commence the ignition sequence supplying heat to the central heating, if required. Note. In normal operation the boiler status display (E) will display messages (see pages 14 & 15). Boiler frost protection - boiler will fire if temperature is less than 5 degrees C. During normal operation the burner on indicator (F) will remain illuminated when the burner is lit. Note: If the boiler fails to light after five attempts the following fault messages will be displayed Ignition Lockout - 1 Check other gas appliances - 2 Reset boiler - 3 Contact Installer. To reset boiler, turn mode knob to reset position and immediately turn knob back to required setting.the boiler will repeat the ignition sequence. If the boiler still fails to light consult a Registered Gas Installer or in IE a Registered Gas Installer (RGII). 7

OPERATION Winter Mode - i.e. CH and DHW required. Ensure the off/summer/winter control (D) is set to winter ( ) The boiler will fire and supply heat to the radiators but will give priority to DHW on demand. The DHW preheat will operate as described under 'Summer conditions' during periods when there is no call for CH. Summer Mode - i.e. DHW only required. Set the mode knob control to Summer ( ). Set the CH external controls to OFF. Preheat will operate with the preheat switch (A) set to ON. The boiler will fire periodically for a few seconds to maintain the DHW calorifier in a pre-heated condition. The average time period between firing is 90 minutes. This may vary considerably due to the surrounding ambient temperature of the boiler. The boiler will fire whenever there is a demand for DHW. The boiler preheat facility can be immobilised by turning the preheat switch (A) to OFF. This will stop the boiler operating for short periods. This facility is primarily provided for boiler installations in a sensitive area (i.e. bedroom etc.). Note. If the pump and diverter valve have not operated in the last 24 hours they will run briefly to ensure they do not become seized. CONTROL OF WATER TEMPERATURE Domestic Hot Water The DHW temperature is limited by the boiler controls to 64 o C maximum at low draw-off rate, adjustable via the DHW temperature control (B). Due to system variations and seasonal temperature fluctuations DHW flow rates/temperature rise will vary, requiring adjustment at the draw off tap : the lower the rate the higher the temperature, and vice versa. 8

Central Heating The boiler controls the central heating radiator temperature to a maximum of 80 o C, adjustable via the CH temperature control (C). Approx. flow temperatures for the boiler thermostat settings are: Knob Setting Flow Temperature Minimum 40 o C (104 o F) Maximum 64 o C (147 o F) The Logic + Combi is a high efficiency combination boiler which is most efficient when operating in condensing mode. The boiler will operate in this mode if the CH temperature control (C) is set to the e position (economy mode) or below. This control should be set to a maximum for very cold periods. TO SHUT DOWN THE BOILER Set the mode knob control to OFF. TO RELIGHT THE BOILER Repeat the procedure detailed in 'To light the boiler'. FROST PROTECTION If no frost protection is provided and frost is likely during a short absence from home, leave the heating controls (if fitted) at a reduced temperature setting. For longer periods, the entire system should be drained. If the system includes a frost thermostat then the timer can be left off (if fitted). The mains supply should be left switched ON, with the boiler thermostat left in the normal running position. BOILER OVERHEAT PROTECTION The boiler controls will shut down the boiler in the event of overheating. Should this occur, a fault code Overheat Lockout - 1 Fill system to 1.0 bar - 2 Bleed radiators - 3 Check radiator valves open - 4 Reset boiler - 5 Contact Installer will be displayed. Reset boiler by turning the mode control knob (D) to reset position and immediately turn knob back to required setting. The boiler will relight. If the fault recurs, turn off the boiler and consult a Gas Safe Registered Engineer or in IE a Registered Gas Installer (RGII). 9

LOSS OF SYSTEM WATER PRESSURE The gauge (G) indicates the central heating system pressure. If the pressure is seen to fall below the original installation pressure of 1-2 bar over a period of time then a water leak may be indicated. In this event conduct the re-pressurising procedure as shown below. If unable to do so or if the pressure continues to drop a Gas Safe Registered Engineer or in IE a Registered Gas Installer (RGII) should be consulted. 1 CLOSED POSITION THE BOILER WILL NOT OPERATE IF THE PRESSURE HAS REDUCED TO LESS THAN 0.3 BAR UNDER THIS CONDITION. In this case the boiler will display Low water pressure 1 fill system to 1.0 bar - 2 Bleed radiators 3 Contact installer. 5 3 4 OPEN To re-pressurise: 1. Ensure filling loop isolation valves are closed. 2. Remove the left hand cap. 3. Attach on the filling loop. 4. Turn the filling loop isolation valves to the open position. The system will now fill. 5. Wait for pressure gauge to reach 1 to 1.5 bar. 6. Close the filling loop isolation valves. 7. Disconnect the filling loop at left hand side and angle upwards. 8. Replace cap. POSITION PRESSURE GAUGE 2 7 8 6 CLOSED POSITION 3G9866 10

CONDENSATE DRAIN The condensate drain (H) must not be modified or blocked. Blockage of the condensate drain, caused by debris or freezing, can cause automatic shutdown of the boiler. If freezing is suspected and the pipe run is accessible an attempt may be made to free the obstruction by pouring hot water over the exposed pipe and clearing any blockage from the end of the pipe. If this fails to remedy the problem the assistance of a Gas Safe Registered Engineer or in IE a Registered Gas Installer (RGII) should be sought. ESCAPE OF GAS Should a gas leak or fault be suspected contact the National Gas Emergency Service without delay. Telephone 0800 111 999 DO NOT SEARCH FOR GAS LEAKS WITH A NAKED FLAME. CLEANING For normal cleaning simply dust with a dry cloth. To remove stubborn marks and stains, wipe with a damp cloth and finish off with a dry cloth. DO NOT use abrasive cleaning materials. MAINTENANCE The appliance should be serviced at least once a year by a Gas Safe Registered Engineer or in IE a Registered Gas Installer (RGII). 11

POINTS FOR THE BOILER USER Note. In line with our current warranty policy we would ask that you check through the following guide to identify any problems external to the boiler prior to requesting a service engineers visit. Should the problem be found to be other than with the appliance we reserve the right to levy a charge for the visit, or for any pre-arranged visit where access is not gained by the engineer. 12

TROUBLESHOOTING NO HOT WATER NO CENTRAL HEATING NO HOT WATER OR CENTRAL HEATING Check the mains switch (fused spur) is turned on and ensure mode control knob (D) is in the summer or winter position Check the mains switch (fused spur) is turned on and ensure mode control knob (D) is in the winter position Check the fused spur is turned on and ensure mode control knob (D) is in the winter position Is water coming out of the hot water tap when turned on? YES See boiler Display Functions section. If standby mode is displayed then contact Ideal Customer Services Helpline if your appliance is under warranty or a Gas Safe Registered Engineer, in IE a Registered Gas Installer (RGII), if out of warranty NO Check the programmer (internal or external to the boiler) is in an ON position and the room thermostat is turned up Does the boiler operate and provide central heating? YES Check the time settings on the programmer are as you require and adjust if necessary NO Does the boiler have a display showing on the front control panel? YES See boiler Display Funcitons section Contact a Gas Safe Registered Engineer or in IE a Registered Gas Installer (RGII) NO Contact a Gas Safe Registered Engineer or in IE a Registered Gas Installer (RGII) See boiler Display Functions section. If standby mode is displayed then contact a Gas Safe Registered Engineer or in IE a Registered Gas Installer (RGII) 13

DISPLAY FUNCTIONS - NORMAL OPERATION MODE The display scrolls through a maximum of 3 messages under any operational condition, as shown below. Note. The temperatures shown below are for illustration purposes only. The measured temperatures will be shown on the boiler. NORMAL OPERATION MESSAGE 1 MESSAGE 2 MESSAGE 3 Mode knob in standby (off) position and no heat demand Standby mode For hot water turn mode knob clockwise For central heating turn mode knob clockwise twice Mode knob in summer ( no heat demand Mode knob in winter ( no heat demand ) position and ) position and Summer mode Winter mode For central heating turn mode knob clockwise Timer or room stat off Domestic hot water operation Hot water Temperature 64ºC High efficiency Central heating operation Central heating Radiator Temp 80ºC High efficiency Pre-heat operation Pre heat Temperature 59ºC High efficiency Boiler frost protection Boiler frost protection Temperature 5ºC High efficiency Pump overrun Pump overrun Fan post-purge Fan post-purge 3G9711b Note. High efficiency will not be shown for central heating operation if the central heating flow temperature knob (c) is set to greater than 73ºC. 14

DISPLAY FUNCTIONS - SETTINGS CHANGED Note. The temperatures shown below are for illustration purposes only. The measured temperatures will be shown on the boiler. NORMAL OPERATION MESSAGE 1 MESSAGE 2 MESSAGE 3 Pre-heat knob moved to off position Pre heat off Pre-heat knob moved to on position Pre heat on DHW temperature knob moved 64ºC DHW temp Hot water temperature 64ºC CH temperature knob moved 80ºC CH temp Maximum radiator temperature 80ºC May not be achieved for high flow rates in winter Mode knob moved to standby (off) position Standby mode Central heating off Hot water off Mode knob moved to summer ( ) position Summer mode Central heating off Hot water on Mode knob moved to winter ( ) position Winter mode Central heating on Hot water on Mode knob moved to reset position Reset 3G9712b 15

DISPLAY FUNCTIONS - FAULT MESSAGES BOILER DISPLAY MESSAGE DESCRIPTION ACTION Outside Sensor Fault Contact Installer Low Mains Voltage Contact Electricity Provider PCB Fault Contact Installer No Water Flow Thermistor Fault Contact Installer Outside Sensor Failure Low Mains Voltage Unconfigured PCB No Water Flow Thermistor Reset the appliance - if the boiler fails to operate then please contact Ideal (if under warranty) or alternatively a Gas Safe Registered Engineer if outside of the warranty period. In IE contact a Registered Gas Installer (RGII). Contact a qualified electrician or your electricty provider. Unconfigured PCB. Please contact Ideal (if under warranty) or alternatively a Gas Safe Registered Engineer if outside of the warranty period. In IE contact a Registered Gas Installer (RGII). Reset the appliance - if the boiler fails to operate then please contact Ideal (if under warranty) or alternatively a Gas Safe Registered Engineer if outside of the warranty period. In IE contact a Registered Gas Installer (RGII). Too Many Resets Contact Installer 5 Boiler Resets in 15 Minutes 1. Turn power off and on at the fused spur. 2. If the boiler fails to operate please contact Ideal (if under warranty) or alternatively a Gas Safe Registered Engineer if outside of the warranty period. In IE contact a Registered Gas Installer (RGII). Lockout 6 Contact Installer False Flame Lockout Reset the appliance - if the boiler fails to operate then please contact Ideal (if under warranty) or alternatively a Gas Safe Registered Engineer if outside of the warranty period. In IE contact a Registered Gas Installer (RGII). 3G9911 16 cont d.......

DISPLAY FUNCTIONS - FAULT MESSAGES BOILER DISPLAY MESSAGE DESCRIPTION ACTION Boiler Type Card Fault Contact Installer PCB Replacement Reset Boiler Low Water Pressure 1 Fill System to 1.0 Bar 2 Bleed Radiators 3 Contact Installer Overheat Lockout 1 Fill System to 1.0 Bar 2 Bleed Radiators 3 Check Radiator Valves Open 4 Reset Boiler 5 Contact Installer No Water Flow Lockout 1 Fill System to 1.0 Bar 2 Bleed Radiators 3 Check Radiator Valves Open 4 Reset Boiler 5 Contact Installer BCC Activation Fault BCC Fault Low Water Pressure Flow Temperature Overheat No Water Flow Reset the appliance - if the boiler fails to operate then please contact Ideal (if under warranty) or alternatively a Gas Safe Registered Engineer if outside of the warranty period. In IE contact a Registered Gas Installer (RGII). Reset the appliance - if the boiler fails to operate then please contact Ideal (if under warranty) or alternatively a Gas Safe Registered Engineer if outside of the warranty period. In IE contact a Registered Gas Installer (RGII). Check system pressure is between 1 & 1.5bar on the pressure gauge. If the fails to operate then please contact Ideal (if under warranty) or alternatively a Gas Safe Registered Engineer if outside of the warranty period. In IE contact a Registered Gas Installer (RGII). Check system pressure is between 1 & 1.5bar on the pressure gauge. Reset the appliance. If the boiler fails to operate then please contact Ideal (if under warranty) or alternatively a Gas Safe Registered Engineer if outside of the warranty period. In IE contact a Registered Gas Installer (RGII). 3G9912 17 cont d.......

DISPLAY FUNCTIONS - FAULT MESSAGES BOILER DISPLAY MESSAGE DESCRIPTION ACTION Flame Loss 1 Check Other Gas Appliances Work 2 Contact Installer Ignition Lockout 1 Check Other Gas Appliances Work 2 Reset Boiler 3 Contact Installer Fan Fault Contact Installer Flow Thermistor Fault Contact Installer Return Thermistor Fault Contact Installer Flame Loss Fan Fault Flow Thermistor Return Thermistor 1. Check other gas appliances in the house are working to confirm a supply is present in the property. 2. If other appliances do not work or there are no other appliances, check the gas supply is on at the meter and/or pre payment meter has credit. If the boiler fails to operate then please contact Ideal (if under warranty) or alternatively a Gas Safe Registered Engineer if outside of the warranty period. In IE contact a Registered Gas Installer (RGII). Reset the appliance - if the boiler fails to operate then please contact Ideal (if under warranty) or alternatively a Gas Safe Registered Engineer if outside of the warranty period. In IE contact a Registered Gas Installer (RGII). Reset the appliance - if the boiler fails to operate then please contact Ideal (if under warranty) or alternatively a Gas Safe Registered Engineer if outside of the warranty period. In IE contact a Registered Gas Installer (RGII). Reset the appliance - if the boiler fails to operate then please contact Ideal (if under warranty) or alternatively a Gas Safe Registered Engineer if outside of the warranty period. In IE contact a Registered Gas Installer (RGII). 3G9913 18

19

February 2010 UIN 204979 A03 Ideal Stelrad Group pursues a policy of continuing improvement in the design and performance of its products. The right is therefore reserved to vary specification without notice. Ideal, P.O. Box 103, National Ave, Kingston Upon Hull, HU5 4JN. Tel. 01482 492251 Fax. 01482 448858. Registration No. London 322 137.