Helical Coil Heaters. Hot Oil Heaters Booster Heaters. CEI Enterprises

Similar documents
Full Product Line. Products for concrete, asphalt &, energy. CEI Enterprises

HEATEC PRODUCTS AND SERVICES FOR THE FOOD INDUSTRY

Packaged Marine Design Thermal Fluid (Hot Oil) Heaters

Thermal Fluid Heaters

Commercial Gas Water Heaters

GB Condensing Gas Boiler

WATER-TUBE POOL HEATERS

DIVISION COMMERCIAL, GRID-TYPE, FINNED-TUBE, GAS DOMESTIC WATER HEATERS

DIVISION FINNED WATER-TUBE BOILERS

WATER-TUBE POOL HEATERS

MECHANICAL VENTING VERSATILITY

Commercial Gas Water Heaters

Fuel-Fired Vertical Tubeless Boilers

FUEL-FIRED VERTICAL TUBELESS BOILERS

Click Here To View Item at

Tradesman Tradesman K Norseman Workman Sun Blast Premier Foreman Torches. New

HHA Lyerly Apartments 75 Lyerly Houston, Texas J. Allen Management Managing Agent

SIOUX WATER HEATERS. Hot Water for Cold Weather Concrete Production. Better Concrete Higher Profits. Sioux Water Heaters and Steam Generators

DIVISION FINNED WATER-TUBE WATER HEATERS

DIVISION FINNED WATER-TUBE BOILERS

Triton Series High Efficiency Boiler

HEATEC PRODUCTS AND SERVICES THAT EXCEED YOUR EXPECTATIONS

Fast, Simple, & Easy to Use. One Company... Three Great Brands!

DIVISION FINNED WATER-TUBE BOILERS

ASPHALT STORAGE TANKS

GB Condensing Gas Boiler

Commercial Gas Water Heaters

Suggested Specification: Benchmark 1.5 Low NOx Gas-Fired Hydronic Boiler(s)

DIVISION FINNED WATER-TUBE WATER HEATERS

XTHERM, TYPE WH - MODELS 1005A- 2005A DIVISION COMMERCIAL, WATER-TUBE, CONDENSING GAS DOMESTIC WATER HEATERS

ONQUEST. Featuring... Condensing Water Heater. Requires no tank linings or heat exchanger linings. Requires no anodes of any type. 10- year warranty.

FINNED WATER-TUBE POOL HEATERS

HHA Bellerive Apartments 7225 Bellerive Houston, Texas J. Allen Management Managing Agent

TOTAL SYSTEM EFFICIENCY: SYSTEM APPLICATIONS & DESIGNS. David Grassl PE Mechanical Engineer Principal

GB Condensing Gas Boiler

KG6RC Series TECHNICAL SPECIFICATIONS FEATURES AND BENEFITS

199,000 to 4,000,000 Btu/h 150 to 4500 Gallons Storage

FINNED WATER-TUBE POOL HEATERS

Typical Specifications For: ADVANTUS TM DOMESTIC HOT WATER SUPPLY Models AV(W)0500 AV(W)4000

Typical Specifications For: ADVANTUS TM DOMESTIC HOT WATER SUPPLY Models AV(W)0500 AV(W)4000

Infi niti Tankless. Water Heater Series Featuring SRT (Scale Reduction Technology) Built to be the Best

SIOUX Water Heaters SIOUX WATER HEATERS. Hybrid Water Heater PWP Water Heater M-1

High Efficiency Commercial Gas Water Heaters

Automatic Circulating Water Heaters

ef Series Residential Condensing Power Vent Water Heaters

Industrial Applications

HIGH-EFFICIENCY COMMERCIAL GAS WATER HEATER 3-Year Tank Warranty 1-Year Parts Warranty

The pictures shown in this folder are but a few samples that illustrate the variety of locations and ways our products are used.

Concrete Applications

TOTAL SYSTEM EFFICIENCY: CONDENSING BOILER SYSTEM MYTH BUSTING. David Grassl PE Mechanical Engineer Principal

Cata-Dyne LH Line Heater & Micro Line Heater

Greater temperature control

THE HARD WATER WATER HEATER

HEATEC TEC-NOTE. Operation and maintenance Heatec thermal fl uid heaters industrial series IMPOPRTANT NOTICE! CONTENTS. Publication No.

CL44eR DISHWASHER STANDARD FEATURES MODEL OPTIONS AT EXTRA COST ACCESSORIES DIRECTION OF OPERATION VOLTAGE. Item # Quantity C.S.I.

BURNERS/ FLARES. VAREC BIOGAS 244W Series WASTE GAS BURNER & IGNITION SYSTEM

Up to 94.6% Thermal Efficiency HIGH EFFICIENCY COMMERCIAL CONDENSING BOILERS OPERATING CONTROL FEATURING A BUILT-IN CASCADING SEQUENCER

SSV Mixers. The clear leader for cleanability, versatility and performance.

Condensing Hydronic Boilers 2,000,000-6,000,000 BTU/HR

Revitalize Building Mechanical Systems (4619)

Innovators in Waste to Energy Products

Power Flame Incorporated

KN2/4 SERIES MASTER SPECIFICATION

SCHMIDT BRAZED PLATE HEAT EXCHANGERS. ...world leaders in heat transfer technology

Key Question. What is the most important aspect to the removal and cleaning of material?

KG6TE Series. High Efficiency / Direct Vent or Non Direct Vent 2-Stage Condensing Gas Furnace with Variable Speed Blower TECHNICAL SPECIFICATIONS

MODEL M5M. High-Efficiency Packaged Watertube Boiler MMBTU

4VH and 4VHX. 4" Non-Clog Wastewater Pumps Standard (4VH) and Explosion-Proof (4VHX) Construction

Multiple Heater Controller TempTracker Mod+, up to 16 heaters

940ES Tankless Water Heater

TOTAL SYSTEM EFFICIENCY: CONTROL STRATEGIES & SYSTEM DISTRIBUTION. David Grassl PE Mechanical Engineer Principal

Field Products. Solutions for Improved Thermal Process Performance

INTRODUCING THE BRADFORD WHITE 24/7 EXPERT SUPPORT CENTER. TABLE OF CONTENTS. Technical Support: Warranty Support:

Suggested Specifications Prestige Excellence 110

FG6T(C,L) Series. High Efficiency / Direct Vent or Non Direct Vent 2-Stage Condensing Gas Furnace with Variable Speed Blower TECHNICAL SPECIFICATIONS

CL64e DISHWASHER DISHWASHER STANDARD FEATURES MODEL OPTIONS AT EXTRA COST ACCESSORIES DIRECTION OF OPERATION VOLTAGE

BEACON/MORRIS RBD SERIES INFRARED RADIANT HEATER

HEATEC ASPHALT TERMINALS

CLPS66e DISHWASHER DISHWASHER STANDARD FEATURES MODEL OPTIONS AT EXTRA COST ACCESSORIES DIRECTION OF OPERATION VOLTAGE

HORIZONTAL FIRE TUBE BOILERS Piping (HVAC) Pumping Equipment (HVAC).

DIVISION FINNED WATER-TUBE BOILERS

Home Builder Product Selection Guide

940ES Tankless Water Heater

Models 1005, 1505, 2005 Up to 99% thermal efficiency!

The world s standard in efficiency. CBEX FIRETUBE

Fully-automatic Gas tankless Water Heater USER'S MANUAL FOR MODEL EZ-101 ISO9001 certified

Cast Line Heaters The Benefits of This Space Saving Electric Heater

C1210ES Tankless Water Heater

C1N & C2N SERIES Fluid heating for light industrial applications

CL64T INDUSTRIAL TOTE WASHER

12711 TOWNEPARK WAY / LOUISVILLE, KY / / FAX

C1050ES Tankless Water Heater

CLE SERIES Fluid heating for emergency eyewash stations

T A B L E O F C O N T E N T S

AFUE 95% Heating Input 50,000 to 200,000 Btuh

96% AFUE Efficiency CONDENSING RESIDENTIAL GAS BOILERS CONTROL WITH ADVANCED USER FEATURES MODELS FROM 80,000 TO 285,000 BTU/HR

Bosch Greentherm T9800 SE 199 Gas Tankless Water Heater

THE RINNAI LUXURY SERIES TANKLESS WATER HEATERS ENERGY-EFFICIENT HOT WATER NEVER LOOKED SO GOOD

VCLEARFIRE. High-Efficiency, Commercial Steam Boiler Horsepower

MECHANICAL. Product Index Mechanical Product Index

Transcription:

Helical Coil Heaters Hot Oil Heaters Booster Heaters CEI Enterprises

Helical Coil Hot Oil Heaters Helical Coil Hot Oil Heaters Overflow Pipe Fill C Standard model without stack heat exchanger Stack Heat Exchanger (optional) Expansion Tank Low Level Control Heater Model Output Btu/hr General Dimensions and Specifications Max. Fuel Usage No.2 (gph) Gas (cfph) Pump Motor HP Volume Flow Rate (gpm) Expansion Tank (gallons) Single-Circuit Heaters Heat Transfer Fluid Required (US Gal.) HCS-100 1,200,000 11 1,560 10 100 175 95 12-9 5-10 8-11 2 5,000 HCS-175 2,000,000 18 2,600 15 150 280 145 14-9 6-4 9-9 2-1/2 6,500 HCS-250 3,000,000 27 3,900 15 150 280 165 15 11 7-4 10-6 3 9,300 Length A Width B Height C Pipe Size D Approximate Weight (lbs) Control Panel Full Modulation Burner B Circulating Pump Coil Inlet HCS-series heater A Oil Return Helical Coil Coil Outlet D HCS-350 4,000,000 36 5.200 15 200 400 250 18-7 8-2 11-2 3 10,700 Multi-Circuit Heaters HC-120 1,200,000 11 1,560 10 100 175 95 12-9 6-8 8-11 2 5,100 HC-200 2,000,000 18 2,600 15 150 280 145 14-10 6-6 9-9 2-1/2 6,600 HC-300 3,000,000 27 3,900 15 150 280 165 15-11 7-6 10-6 3 9,500 HC-400 4,000,000 36 5,200 15 200 400 250 18-7 8-4 11-2 3 10.900 The amount of fuel used is for a thermal effi ciency of 85% and one hour of operation at maximum output. A properly sized heater normally runs for intermittent periods at lower outputs. No. 2 fuel usage is based on 132,000 Btu per gallon, its LHV (low heating value). Natural gas usage is based on 905 Btu per cubic foot, its LHV. Heights include the exhaust stack without a stack heat exchanger. The stack heat exchanger for the HCS-350 and HC-400 weighs 800 pounds and adds 2-7 to their height. For all other models it weighs 460 pounds and adds 1-9 to their height. NOTE: Specifications are subject to change without prior notice or obligation. Helical Coil Heaters are available in two basic confi gurations: HCS-series for single hot oil circuits, and HC-series for multiple hot oil circuits. Four standard models are available in each series, with outputs from 1.2 million to 4 million Btu/hour. All heaters can be customized to meet your specifi c needs. Single Circuit Systems: Small plants with only one or two liquid asphalt tanks usually need only one hot oil circuit with one pump. HCS-series heaters are well-suited for such plants. One circulating pump, mounted on the heater skid, circulates the heat transfer oil through the heater and through heated plant components. Multiple Circuit Systems: Plants with storage silos, multiple asphalt tanks, and additional components can usually benefi t from using multiple hot oil circuits. HC-series heaters are designed for such applications. They feature a manifold on the output connection that 2 HC-SERIES HEATER WITH MANIFOLD FOR MULTIPLE CIRCUITS supplies oil to multiple additional pumps. Each of these side pumps is dedicated to an independent hot oil circuit. Using multiple circuits reduces the load on each pump, its motor, and its operating pressure. This system is much more fl exible than a single-circuit system because each circuit can be operated independently. OPERATION & FEATURES Centrifugal Circulating Pump, mounted on the heater skid, circulates heat transfer oil through the heater. Viton shaft seal rings provide a reliable seal with virtually no leakage. If the heater is equipped with an optional stack heat exchanger, the oil first enters the exchanger, where it is heated by hot exhaust gases. Oil then exits the stack heat exchanger and enters the helical coil, where it is heated by hot gases from the burner. Full-Modulation Burner conserves fuel, reduces temperature overshooting and eliminates constant on-off burner recycling. The burner fi res into the open center of the helical coil, creating the fi rst pass of hot burner gases. Burner gases then turn at the end of the coil, making a second pass along the coil s outer surface. Helical Coil is designed and built to ASME code. It is designed to provide a large heat transfer surface area, low fl ux rates, and an ideal fl uid velocity of 7 to 11 feet per second. ASME stamp is HELICAL COIL available as an option. Stack Heat Exchanger is an available option that can boost the heater s thermal effi ciency by 5%. Hot burner gases exiting the heater pass around a densely packed set of serrated finned tubes inside the heat exchanger. Thermal oil fl owing inside the tubes is heated before entering the helical coil. This option reduces fuel usage by reducing the output demand placed on the burner. This can reduce fuel consumption by 261 gallons of No.2 fuel oil or 345 therms of natural gas per month. A stack heat exchanger usually pays for itself in one year, or less. UL-rated, NEMA 4 Control Panel is the nerve center of the heater s temperature control and safety systems. Compliance to UL standards not only assures you of the quality of the electrical system, it also puts your insurance company at ease, potentially bringing you lower premiums. The NEMA 4 enclosure provides watertight protection against splashing water, hose-directed water, rain, sleet, snow, ice, dirt, and windblown dust. Panels that meet CSA specifi cations, and other NEMA standard enclosures are available optionally. Temperature Controllers: Two microprocessorbased controllers provide control over output temperatures. The Temperature Controller regulates the fl ow of fuel and combustion air to the burner to efficiently maintain the temperature set point on the controller. The High Media Controller is a safety control. It will shut down the burner if the heat transfer oil reaches the temperature limit set on this controller. Flame Monitor is a microprocessor-based burner management control system. The monitor provides TEMPERATURE CONTROLLERS & DIGITAL ANNUNCIATOR proper burner sequencing, ignition and fl ame monitoring protection. In conjunction with limit and operating controls it sequences the burner/blower motor, ignition, and fuel valves to provide for proper and safe burner operation. Other features include: Self-diagnostic for safety and reliability. Non-volatile memory retains information even when power is interrupted. Microprocessor-based for accurate timing, comprehensive diagnostics and precision control. 3

Helical Coil Hot Oil Heaters Helical Coil Hot Oil Heaters HCS-SERIES HEATER FOR SINGLE HOT OIL CIRCUIT. SHOWN WITH OPTIONAL STACK HEAT EXCHANGER. Digital Annunciator visible on the front of the control panel displays heater status at all times. Any safety limit that is exceeded will immediately shut down the burner. The cause will be clearly displayed on the LCD screen, reducing down time and assisting CEI Service personnel diagnose any heater issues remotely, if necessary. Wireless Monitoring Systems are optionally available for additional convenience and reduced down time. These systems communicate any heater shutdown issues to your cell phone, so you will know what s happening with your heater, no matter where you are. Fuels: The heaters operate on natural gas, LPG, or No. 2 commercial grade fuel oil, depending on the burner used. An optional combination burner allows switching between two different fuels. 4 Thermal Efficiency: Aside from safety and reliability, thermal effi ciency is probably the most important aspect of any heater. CEI s helical coil heater approaches the theoretical limits of thermal effi ciency possible in a fi red 2-pass heater. Even without the stack heat exchanger, its effi ciency is 85 percent. Efficiency Gallons / hour Gallons / Month Gallons / Life 50% 15.0 10,830 2,020,969 60% 12.5 9,008 1,680,806 70% 10.7 7,773 1,450,484 80% 9.5 6,815 1,271,661 85% 8.9 6,406 1,195,307 88% 8.6 6,198 1,156,565 These usages are based on a 1-million Btu/hr heat load, operating 24 hrs/day, 7 days/week, 40 weeks/yr, a 20 year heater life and No. 2 fuel oil with a heating value of 132,000 Btu/gallon (LHV). Available Options: Low-NOx burners (30ppm). Ultra low-nox burners (less than 9ppm). Stack heat exchangers for boosting fuel effi ciency. Optional burner management system utilizes an exhaust stack O 2 sensor to maintain heater operation in adverse climates. Reduces fuel consumption and tunes burner automatically. Sock fi lters for longer fl uid and pump life. 7-day time clock. Non-standard voltage (525/60, 380/50) ASME code stamp. CSA approved panel CRN stamped coils Class I Div. I or Class I Div. II explosion-proof components. High-temperature (550 F) operation. Heat Transfer Fluid Specs The heat transfer oil should be paraffi n base, solvent refi ned and recommended for operating temperature to 450 F. WARNING: Do not mix paraffi n base oils with aromatic base oils. Mixing will clog and severely damage the heater and heating system. Gravity API 28-30 Flash Point Viscosity at 100 F Viscosity at 210 F Viscosity Index Pour Point 420 F 200 SSU 50 SSU 95 Min. 5 F Carbon Residue 0.10% Neutralization No. 0.10% Sulphur Content 0.5% Max. Maintenance: The heaters are very easy to maintain. Components are easy to reach. Replacement parts are readily available from CEI s large parts inventory. We back our products with worldwide parts & service support. 5

Helical Coil Heaters Helical Coil Heaters ADDITIONAL CONFIGURATIONS Vertical Helical Coil Heaters occupy a relatively small ground footprint, allowing placement of a higheroutput heater in a confi ned space where a horizontal heater of the same output may be too large. Many options are available. All heaters can be customized to meet your specifi c needs. Asphalt Booster Heaters are a variation of the vertical helical coil heater design. Liquid asphalt is pumped through the coil, where it is heated in the same manner as a two-pass hot oil heater. Booster heaters are used at bulk storage terminals to boost the temperature of liquid asphalt as it is pumped into a tanker truck for delivery to end users. This allows the terminal to store liquid asphalt at lower temperatures, yet still provide delivery at or near usage temperatures. Third Pass First Pass Second Pass OPERATION OF A 3-PASS HELICAL COIL HEATER 6 VERTICAL HELICAL COIL HEATER ASPHALT BOOSTER HEATER Three-Pass Helical Coil Heaters provide higher outputs than two-pass heaters of the same physical size. By elongating the path of burner gases to the exhaust, the three-pass design performs at high thermal effi ciency. Three-pass heaters utilize two helical coils: a smaller inner helical coil fi ts inside a larger outer helical coil. The burner fi res down the center of the inner coil, creating the fi rst pass of hot burner gases. This pass exposes the inner coil to both radiant and convective heat. At the end of the coil, the burner gases turn and pass through the space between the two coils, creating the second pass. This exposes both coils to convective heat. At the end of the second pass, the hot burner gases turn and pass along the outer surface of the outer coil, creating the third pass and exposing the outer surface of the outer coil to convective heat. Heat transfer oil fl owing through the two coils, either sequentially or in tandem, gains heat from the hot coils. Many options are available. All heaters can be customized to meet your specifi c needs. 3-PASS HEATER ON A CEI ASPHALT RUBBER MIXING SYSTEM 7

Equipment. Parts. Service. Rely on CEI. A legacy of innovation and quality since 1969. 2015 CEI Enterprises, Inc. Publication # 15-04-004 CEI ENTERPRISES,INC. an Astec Industries Company 245 WOODWARD RD, SE ALBUQUERQUE, NM 87102 USA 800.545.4034 FAX 505.243.1422 ceienterprises.com