Installing the Vacuklav 40-B / 44-B

Similar documents
Operating Manual. for the. Autoclave. Thank you very much for the trust which you have shown by purchasing this autoclave.

Technical Description. for the. Autoclave. Thank you very much for the trust which you have shown by purchasing this autoclave.

hinge right B 1 85 cm + 6,5-7 cm max. height of the device feet B cm B 3 85 cm D 2 75 cm (with a maximum opening angle of 170 )

Operating Manual. Reverse Osmosis Water Purifier. MELAdem 55

The Premium-Evolution series. The new benchmark for steam sterilizers

Operating Manual. for the. Autoclave. Thank you very much for the trust which you have shown by purchasing this autoclave.

Operating Manual. for the. Autoclave. Thank you very much for the trust which you have shown by purchasing this autoclave.

MELA dem Everything you need for water treatment

S CLASS AUTOCLAVES & STERILISATION 5,995 6,995 5,995. Euraklav 23 VS+(22L) Euraklav 29 VS+(18L) Euraklav 23 S(22L)

User Manual. Vacuklav 24 B+ Vacuklav 30 B+ as of software version Steam sterilizer. Dear Dr.

User Manual. Vacuklav 24 B/L+ Steam sterilizer. as of software version Dear Dr.

INSTRUCTIONS CertoClav EL

OPERATING INSTRUCTIONS KSG 40/60-2 KSG 50/70-2 KSG 50/80-2 KSG 50/95-2

O P E R A T I N G I N S T R U C T I O N S

SCHWAN INSTALLATION GUIDE

Manual Page 1 of 8. Manual. Laboratory autoclave

Manual v1 Page 1 of 19. Manual. Laboratory autoclave

O P E R A T I N G I N S T R U C T I O N S

MELAG. Complete solutions for instrument decontamination Export-Pricelist 2017 MELAG. All. Products at a glance! Big autoclaves.

PRODUCT CATALOG MEDICAL AUTOCLAVE.

User Manual. MELAtronic 15 EN+ Autoclave. as of software version Dear Dr.

Advance Autoclave. Designed to give you more for your money with a high capacity for faster throughput: More features and benefits...

Getinge HS33. Article List. General Specification

Service Instructions. for the MELAG Autoclaves. MELAtronic 23. Technische Ă„nderungen vorbehalten

Installation guide COMBI. Before installing read this guide first

SAFETY AND OPERATING MANUAL

Advance Autoclave. Designed to give you more for your money with a high capacity for faster throughput: More features and benefits...

Cold water HD 9/18-4 ST

CROWN WATER HEATERS CPU10 - CPU15 CPOS10 - CPOS15

User Manual. Vacuklav 23 B+ Vacuklav 31 B+ Steam sterilizer. From software version 5.15

NO PRE- WASHING CONCEPT

Dansereau Dental. P r e - C o n s t r u c t i o n G u i d e

Operation Manual. Trash Water Pump ARTICLE Image similar

PLEASE TAKE TIME TO READ THIS MANUAL

PRE AND POST VACUUM CLASS B AUTOCLAVE

Wet and dry vacuum cleaners NT 70/3

English. Your Model Number is: HD1500 IMPORTANT

HDC Standard. Stationary high-pressure cleaner for the simultaneous use of 2 to 8 take-off points. Modular design. Intelligent pump control

SCHWAN INSTALLATION GUIDE

Unvented Electric Water Heater 10/15 litre Undersink

Operations Manual. Part Number: For Research Use Only

AZTECA A LITRE STERILISER

CRAFTSMAN EXAMINATION, JUNE 2007 PLUMBING QUESTION AND ANSWER BOOKLET. Time allowed THREE hours

LABORATORY VERTICAL AUTOCLAVE

Cold water compact class Xpert HD 7125 *AU. Standard accessories: High-pressure hose 10 m Spray lance 380 mm Anti-twist system Pressure cut-off

Trouble Shooting and Help Guide TT / TTB 1840

HD 5/12 C Plus. Compact, high performance pressure washer with unique stand-up or lay-flat operating positon and large carry handle.

Cold water compact class HD 5/12 C

INSTANT HOT WATER DISPENSER

Pre-Installation Instructions. Installation Instruction. Installation Instructions. kah. wall. Warning. User s Manual and warranty

Wet and dry vacuum cleaners NT 70/3

Water Distillation System Instruction Manual Nutriteam TC-501

RIOS 3 USER MANUAL MILLIPORE

Glass and Dishwashers 402/452/502. (original instructions) (incl. Australian /502) Starting from Serial No.:

CONVENTUS CAGE TM PH Procedure Instruments Instrument Tray Cleaning and Sterilization

Fountain Classic. Installation and Owner s Manual. Page 16

Operation Instructions

Wet and dry vacuum cleaners NT 70/2 Adv

CAIRplus ECOTWINcool SUPPLEMENT TO OPERATION MANUAL

AUSTRALIA PAD1200-XE NEW ZEALAND

Hood Type Dishwasher WD-6 BECAUSE WE DO CARE

Pipe Sizing Table. Hydraulic Load Served (fixture units)

Operation Manual Portable Room Air Conditioner Models: RPC26WA / RPC35WA / RPC41WA

BioMaster 250/350/600 BioMaster Thermo 250/350/600

SUPPLEMENT TO OPERATION MANUAL Modular Air Handling Units CAIRplus ECOTWINcool

Installation guide Sahara & Sahara Plus

J-PRO-24 Soda Ash Injection Installation & Start-Up Guide

HDS 6/14 C. Large tilting aid. eco!efficiency mode. Economical and environmentally friendly even during longer periods

GV93XX PRO EXPRESS ok_110x154 01/03/10 11:22 Page3

FOR PRODUCT/WARRANTY REGISTRATION Go to Click on SUPPORT at the top of homepage Click on PRODUCT REGISTRATION

Bluestone Industrial & Trading Limited

Cold water compact class HD 5/12 C Plus

541D19 SERIES. Technical Manual. A Division of Aquion Partners L.P.

MiniVap Humidifier Models LMV2 & LMV4

Carpet washer. Vax careline V-135B. Vax model number:

Equipment Alert. P-Trap Must Be Installed to Exhaust or Warranty will be Voided. Refer to this Manual for installation Instructions

by Water Purification Supplies

MW & EW 10 & 15 Litre Unvented Water Heaters HANDBOOK. IMPORTANT: This booklet should be given to the customer after installation and demonstration.

* depending on model.

CONVENTUS CAGE TM PH Procedure Instruments Instrument Tray Cleaning and Sterilization

HOT TANK INSTALLATION INSTRUCTIONS

TTB 345 OPERATION - INFORMATION INDEX 1. Part Identification Diagram 2. Basic Operation Instructions 3. Do s and Don ts 4. Fitting The Brush / Drive B

Parasitic Cysts - Cryptosporidium and Giardia, Chemicals, Heavy Metals, Dissolved Salts, Offensive Tastes and Odours, Sediment, Dirt,

HD 6/13 C. Compact, high performance pressure washer with unique stand-up or lay-flat operating positon and large carry handle. 3 Accessory storage

Instruction Manual. B Issue B. next Pump Accessories

FOOD WASTE DISPOSER INSTALLATION AND USE MANUAL

BACKFLOW PREVENTION GUIDE FOR COMMERCIAL, INSTITUTIONAL AND INDUSTRIAL DEVELOPMENTS

Special Requirements For Health Care Facilities

INSTALLATION GUIDE NZ AU

APPENDIX 4. Thank you for choosing the Biomega BioClave steam sterilizer. HYDRAULIC DRAWING

Installation Instructions. For the 18 Built-In Dishwasher and Front Color Panels

2 - Hood DESCRIPTION CABLE HOLDER PG16 WITH HOLE PLUG FOR DOOR (BR-BC-FC) SLIDING WASHER TIE ROD FC

CF SERIES CF100 CF200 CF300

Vortex 15/21 Utility and Outdoor Module Vortex Combi 21 and Outdoor Vortex Combi 21

INSTALLATION MANUAL. Manufactured by AQUA-AIR MANUFACTURING. (801) or (800) FAX (801)

Tabletop 2340 EA-D Class S Autoclave 19 Litres

Table of Contents. List of Figures

3/4 HP Model Trimmer Operating Instructions

WATT R TWIN Energy-Efficient Home Water System

Operating manual. Instrument washer. MELAclean. Thank you very much for the trust that you have shown in our products by purchasing this unit.

Transcription:

Installing the Vacuklav 0-B / -B Please read the operating manuals of the autoclave and of the water purification unit first! The Vacuklav 0-B / -B are autoclaves with fractionating pulsed vacuum procedure. A water ring pump has been installed to generate the especially deep vacuum, combining the advantages of high effectiveness and extreme sturdiness in permanent operation. Please read the following important instructions to be followed prior to and during installation in order to connect the required water pipe and for general installation. Views of the unit, dimensions, control and connecting elements 0 0 (0) * () * () * *) The values in brackets apply to the Vacuklav -B Figure : Views of the Vacuklav 0-B / -B Anti cavitation nozzle Power switch Safety valve chamber Ethernet (data connection) *) Sterile filter Front adjustable feet Safety valve casing Pressure gauge for pressure display of Cooling water inlet (/" external thread) the double casing steam generator *) Reset button overheating protection *) Reset button motor circuit breaker *) Purified water inlet (Swivel connection for x pipe, alternatively straight) Cooling water outlet (/" external thread) Cover for emergency start of vacuum pump Mains power cable Cover for opening door in emergency cases Ethernet (data connection) 0 Door (left-side hinge) 0 Ethernet (data connection) Control and display panel Ventilator Movable cover for CF-Card *) accessible behind cover to the right *) accessible behind round cover Page of

Preconditions for and instructions on installation Installing the Vacuklav 0-B / -B Prior to setting up and installing the autoclave, please ensure that the following preconditions are met and follow the below instructions:. Transport ribbons Take the autoclave out of the packaging by means of the transport ribbons. The ribbons themselves are each removed by undoing the four retaining screws on each side, which must then be screwed firmly back in place without washers. Please keep the transport ribbons and the washers for future transports. After starting the appliance, open the door immediately and remove the trays and accessories.. Required space Based on the dimensions of the appliance (see Figure ), allow for a minimum additional space of 0 cm on both sides and above the appliance to ensure appropriate air circulation. Space for the MELAG storage container for purified water (D=0 mm W=0 mm, H=0 mm), alternatively for a water purification unit MELAdem, MELAdem 0 or other storage containers such as the original container of the supplier.. Horizontal working surface / carrying capacity The appliance should be installed on an even, horizontal working surface. The weight of the appliance (without load) amounts to kg (for the Vacuklav 0-B) and to kg (for the Vacuklav -B).. Power connection Mains power connection 0 V, 0 Hz, rating 00 VA, separate power source with A fuses, additional circuit breaker 0 ma. The power connection cable of the autoclave has a length of. m. If the separate printer MELAprint is connected to the autoclave, please ensure the availability of an additional mains power supply for the power unit of the printer.. Water connection of the Vacuklav 0-B / -B to a non-return valve The connection of the Vacuklav 0 B / -B to the water pipe can be compared to connecting a washing machine at home. According to EN, consumers must be connected to the potable water system so that the potable water cannot be soiled. In compliance with EN Section, the autoclave should be equipped with a safety combination consisting of a non-return valve and an anti-vacuum device at the water inlet of the autoclave backside, in order to protect the potable water system. Frequently, this is already the case in many buildings. Consult your plumber! In practice, it is a good idea to use water taps that are equipped with such a safety combination (non-return valve and anti-vacuum device). In order to ensure a standard connection of the Vacuklav 0-B / -B independent on existing installations in the building, we recommend the installation examples in Figure. Type I: separate water pipe (nominal width DN with /" faucet) exists or is installed. Installation of a water tap with integrated safety combination (MELAG Art.-No. 0). Type II: Cold water pipe (e.g. of a sink) with stop cock and 0 mm pipe exists or is installed. Installation of an additional water tap with integrated safety combination (MELAG Art.-No.: 0) directly mounted to an existing stop cock. Required running pressure at a flow rate of litre / min > 0. bar. Length of the cooling water inlet pipe to the Vacuklav 0-B / -B: m (. m can be delivered as an option). We recommend installing a leak detector with stop valve ( water stop, Figure, Figure, Figure, MELAG Art.-No.: 00). Page of

Installing the Vacuklav 0-B / -B Figure : Water connection Type I Water tap with non-return valve and anti-vacuum device MELAG Art-No.: 0 Type II Additional water tap with non-return valve and anti-vacuum device (to be mounted to an existing stop cock) MELAG Art-No.: 0 0 mm cold water pipe (to the mixing battery) Existing stop cock Cooling water inlet pipe (DN ). Cooling water outlet The cooling water outlet requires a wall-mounted trap, nominal width DN 0 or a sink trap. Examples for the waste water outlet are shown on pages and. For silent connection of the cooling water outlet to an existing sink trap, MELAG offers a special doublechamber trap to be used instead of the existing trap. For connection of the autoclave to the waste water, MELAG supplies a waste water pipe with a length of metres; as an option you can also order a pipe of metres. The outlet should be located at least 0 cm below the autoclave and the waste water pipe between these two should have a steady downward gradient, without twists and kinks. Feed water supply (purified water) Since soiled feed water in autoclaves with a water circulation system regularly results in premature damage of the autoclave and the instruments, the Vacuklav 0-B / -B works with the gentle one-way system. The autoclave is automatically supplied with feed water, either from the internal storage container (which the practice team keeps filled with, for instance, distilled water from the MELAdest ), or even more comfortable, fully automatically from the water purification unit MELAdem or MELAdem 0. The feed water (for steam generation) should meet at least the values of demineralised water according to VDE 00.. Indirect supply (example page, Figure ) The Vacuklav 0-B / -B supplies itself with purified water from the storage container by means of the supplied suction pipe of metres. The maximum suction height is. m. Naturally, the storage container can be located at the side of the appliance.. Direct supply (example page, Figure ) Connection of the ion exchanger MELAdem 0 with MELAjet Most simply, the MELAdem 0 can be connected directly to the feed water inlet of the Vacuklav 0-B / - B; it then generates demineralised water from normal tap water. The spray-pistol MELAjet serves for final rinsing of the instruments with demineralised water prior to sterilization. Page of

Installing the Vacuklav 0-B / -B. Direct supply (example page, Figure ) Connection of the reversed osmosis unit MELAdem The MELAdem can be connected directly to the feed water inlet of the Vacuklav 0-B / -B. Please consult MELAG prior to connecting other pressure water purifiers with the appropriate water quality. Installing the appliance Please ensure that sufficient space is available when installing the appliance, see point.. Installation materials MELAG supplies the following installation materials: cooling water inlet pipe ( m), Art.-No. cooling water outlet pipe ( m), Art.-No. double-chamber trap, Art.-No. storage container with. m inlet pipe and suction filter (in case of installation as in Figure ) inlet pipe. m and inlet nozzle (in case of installation as in Figure or Figure ) You can order additional installation materials by means of the following article nos.: Wall-mounted trap with Y-junction MELAG Art.-No.: 0 Y-junction with non-return valve for connection to existing sink trap MELAG Art.-No.: 00 Water tap / (with safety combination) MELAG Art.-No.: 0 Additional water tap with non-return valve and anti-vacuum device (for connection to an existing stop cock) MELAG Art.-No.: 0 Leak detector with stop valve and sensor MELAG Art.-No.: 00 Installation examples. Example : The feed water is suctioned from the storage container and let out via the double-chamber sink trap 0 Vacuklav 0-B/-B rear view Cooling water inlet nozzle Cooling water outlet nozzle Feed water inlet nozzle Y-junction with non-return valve (MELAG Art.-No.: 00 included in wall mounted surface type trap (MELAG Art.-No. 0)) Wall outlet (NW 0) available in the room) Double-chamber trap (MELAG Art.-No. part of delivery) or wallmounted surface type trap (MELAG Art.-No. 0 - option) Storage container for purified water (DxWxH 0x0x0 mm) Feed water intake with filter 0 Cooling water outlet pipe DN Cooling water inlet pipe (pressure pipe) Water tap (available in the room) Power connection Leak detector with stop valve and sensor (MELAG Art.-No.: 00 - option) Safety combination consisting of non-return valve and anti-vacuum device acc. to EN Figure Page of

Installing the Vacuklav 0-B / -B. Example : The feed water is supplied from MELAdem 0 and let out via the double-chamber trap 0 MELAjet (MELAG Art.-No.: 000) option MELAdem 0 Feed water inlet nozzle demineralised water (MELAG Art.-No.: part of delivery) Inlet pipe purified water Feed water filter MELAdem Wall outlet (NW 0 available in the room) Double-chamber trap (MELAG Art.-No.: part of delivery) Y-junction with non-return valve (MELAG Art.-No.: 00 included in wall mounted surface type trap (MELAG Art.-No. 0)) Cooling water outlet pipe DN 0 Cooling water outlet nozzle Cooling water inlet nozzle and branch socket (MELAG Art.-No. part of delivery) Cooling water inlet pipe (pressure pipe) Water tap (available in the room) Power connection Leak detector with stop valve and sensor option (MELAG Art.-No.: 00) Vacuklav 0-B/-B rear view Safety combination consisting of non-return valve and anti-vacuum device acc. to EN Figure. Example : The feed water is supplied from MELAdem and let out via the double-chamber trap 0 Vacuklav 0-B/-B rear view Cooling water inlet nozzle Cooling water outlet nozzle Feed water inlet nozzle Bleeder tap purified water Feed water filter MELAdem Wall outlet (NW 0 available in the room) Double-chamber trap (MELAG Art.-No.: part of delivery) Y-junction with non-return valve (MELAG Art.-No.: 00 part of delivery) 0 Concentrate outlet of MELAdem Inlet pipe purified water MELAdem Cooling water outlet pipe DN Cooling water inlet pipe (pressure pipe) Water tap (available in the room) Power connection Leak detector with stop valve and sensor (MELAG Art.-No.: 00 - option) Y-junction ¾ (MELAG Art.-No.: 00 part of delivery) Safety combination consisting of non-return valve and anti-vacuum device acc. to EN Figure IA_00-00_GB_0B_B.doc Rev.: 0 0/0 Page of