EXHAUST FAN FLOW METER AND TRUEFLOW AIR HANDLER FLOW METER

Similar documents
Click Here To View Item at

Minneapolis Duct Blaster

Minneapolis Duct Blaster

Residential Air Leakage (Blower Door) Testing for Florida Code Compliance

Are you Getting Your Fan Flows Right?

Chapter Eight RESNET Standards

Published by the California Building Performance Contractors Association

Using a Pressure Pan To Diagnose Duct Leakage

Minneapolis Blower Door

Duct Design and Installation

Multifamily Ventilation Assessment and Retrofit Guide

In accordance with the Department of Labor and Industry s statute , Subd. 11,

SONOMA COUNTY ENERGY INDEPENDENCE PROGRAM POLICIES AND PROCEDURES MANUAL TOOL LENDING LIBRARY

Technical Standards for the Air Conditioning and Heat Pump Professional BPI STANDARDS

In the past, contractors sized heating and cooling systems GETTING HVAC RIGHT

ENERGY STAR Qualified Homes

ANSI/RESNET/ICC

Performance and Reliability. CB*, C* and TA* Models

TO THE FOR PRESCRIPTIVE COMPLIANCE OF FOR RESIDENTIAL ALTERATIONS

Hood Depot Internatioonal, Inc., Phone S. Powerline Road, Deerfield Beach, FL

Ventilation Techniques. Topic 5 - Audio 53

DUCT LEAKAGE (Page 1 of 3)

EHH SERIES DRAW THROUGH FAN COILS CFM

Ventilation Fan Model VFB24ACTH VFB24ADTH VFB24AXTH

BCE4 PRODUCT SPECIFICATIONS ENHANCED AIR HANDLER WITH VARIABLE SPEED APPLICATION INSTALLATION CABINET COMPONENTS CONTROLS WARRANTY

CITY OF DANA POINT. COMMUNITY DEVELOPMENT, BUILDING AND SAFETY Golden Lantern, Suite 209 Dana Point, CA

VentZone Systems VentZone Zoned IAQ with Heat Recovery Kits

SH, VH & SE Models. SH, VH & SE Series Heat & Energy Recovery Ventilators IMPORTANT - PLEASE READ THIS MANUAL BEFORE INSTALLING UNIT

WAP Pressure Diagnostics Procedure. Page 1

Capt. Tim s s Duct Design Mythbusters. The bitterness of poor quality is remembered long after the sweetness of low price is forgotten!

HVAC Equipment Access Equipment Location

Illinois Home Weatherization Assistance Program - Field Standards Manual

Objectives. Home Performance Diagnostics with the House of Pressure (Part 1) How can Pressure effect Building Performance?

HR150B, HR200B Perfect Window Fresh Air Ventilation Systems

LABGARD NU-602 CLASS II TYPE A2 ANIMAL HANDLING BIOLOGICAL SAFETY CABINET

VentZone Systems VentZone Zoned IAQ with Energy Recovery Kits

High Plume Blowers Suggested Specification Section (Master Format 1996) Suggested Specification Section (Master Format 2004)

Air Handlers and Indoor Coils Up to 20 Tons. CB* and C* Models. True performance and rugged durability

Plenum Fans. Model HPA. Direct Drive

In accordance with the Department of Labor and Industry s statute , Subd. 11,

Outside Air Requirements... SOLVED!

Applying ducted, split-ductless systems. in High-Performance Homes

SAFETY AND INSTALLATION MANUAL MODEL 8100

ENERGY STAR V2.5 & 3 Designed to Qualify AIA Annual Convention

CB18/CBS18 Bulletin # September 1994 Supersedes August 1986

When Duct Sealing Kills HVAC Equipment and Efficiency

Effects of Kitchen Ventilation on Residential Dwellings

True performance and rugged durability. TU, LF and LD Models

APPLICATION, INSTALLATION, AND MAINTENANCE MANUAL CA2XRT, CA3XRT, CA4XRT

Working With DHPS and Other Variable Capacity Heat Pumps. October 05, 2017

Ventilation for New Low-Rise Residential Buildings July 20, 2015

SSL / SBS Sales Guide BLOWER-COILS REDUCED-FOOTPRINT, VERTICAL

REFLECTOR PANS FOR HINGED ELEMENTS CONNECTOR BLOCK KIT TRIM RINGS FOR ABOVE PANS CONNECTOR BLOCK RANGE CORD REFLECTOR PANS FOR PLUG-IN ELEMENTS

Florida Department of Transportation

Basic Hood Considerations The design process for a successful kitchen ventilation system starts when the engineering design HVAC team receives

Performance and rugged durability. Commercial Split Systems Up to 20-Ton TSA/TPA Models

TECHNICAL SPECIFICATIONS

Ductless and ducted mini splits- with case studies. Heat Pump and Air Condi1oning For Energy Design Conference By Mike D. Wilson- Dakota Supply Group

Ventilation Solutions IAQ Canada

Hydronic Air Handler Powered by Tankless Technology

SPLASHPROOF AXIAL EXTRACT FANS USED TO EXTRACT AIR EITHER DIRECTLY TO THE OUTSIDE OR INTO DUCTING UP TO 4m LONG

RESNET National Conference New Orleans, LA. February 15, 2009 Presented by Rich Moore Invisible Energy Denver, CO

installation, operation & Maintenance manual Floor-mounted Induction units acb 30/35

AIR HANDLERS. Central Station (CS3) Roof Mounted (RT) (Modular AL Frame AHU)

research highlight Assessment of Suite Compartmentalization and Depressurization in New High-Rise Residential Buildings

VertiCool Space Saver 2 to 15 Tons Water-Cooled and Chilled Water Air-Cooled w/remote Condenser

Measured Duct Leakage at Operating Conditions in 48 Homes

NAHB Green Home Building Guidelines. 3.1 Prerequisites. ResCheck. Energy Efficiency

Installation Guide. Model: IC15- MF Model: IC15- MFSilent Model: IC30- MF Model: IC30- MFSilent

Why ventilate? Dilute contaminants Control or aggravate humidity Comfort or lack of cooling Odors Provide oxygen

InspirAIR Compact Heat and Energy Recovery. Multi-Family HRV/ERV

The Current (2017) State of the Art for Air Leakage in Ductwork

SECTION PLUMBING/HVAC FINAL TESTING, ADJUSTING AND BALANCING

How to Take Basic Readings to Show Energy Efficiency

Cased Aluminum Coils "Dedicated Upflow / Downflow" Convertible to horizontal with separately purchased kit

2016 BUILDING ENERGY EFFICIENCY STANDARDS RESIDENTIAL HVAC ALTERATIONS

Dwelling Ventilation Strategies, Including ASHRAE 62.2 ASHRAE Ventilation for Acceptable Indoor Air Quality

EARTH ADVANTAGE HVAC REQUIREMENTS

TR Series - The Ultimate ERV

WHAT S CHANGED WITH ANSI/RESNET/ICC STANDARD 380. Iain Walker, Residential Building Systems Group

MODELS TR & TRC TOTAL RECOVERY FOR ALL CLIMATES RESIDENTIAL OR COMMERCIAL APPLICATIONS

NEW DAIKIN FTQ SERIES HEATING AND COOLING SYSTEMS. MULTI-POSITIONAL AIR HANDLER Up to 16 SEER / Up to 10.4 HSPF / Up to 12.5 EER

Residential Heat Recovery Ventilation. REHVA European Guidebook No 25

SECTION AIR OUTLETS AND INLETS

Welcome. High Performance Mechanicals for Houses That Work. Energy Design Conference - Duluth, MN. February 21 st, 2018

FAN TERMINAL UNITS Constant Volume (Series Flow), Standard Design

Pharmaceutical Facility Design

MultiFamily Ventilation Updates: ASHRAE 62.2, Best Practices and Practical Applications RESNET Conference Atlanta, GA

SECTION 7 AIR CONDITIONING (COOLING) UNIT 38 INSTALLATION

FirstEnergy Program Overview

Landmark. Commercial Packaged Rooftop Units 2- to 25-Ton KG/KC/KH Models. Up to 13.0 SEER, 14.0 IEER. Performance Marked by Flexibility

Inffusers. idl20 (2 WAY) ids60 (4 WAY)

EFFICIENT DUCT SYSTEM DESIGN

AcoustiFlo Fans: Retrofit Solutions and Beyond

DucTester Operation & Testing Manual

SMART ERV Energy Recovery Ventilator. Build It Tight / Ventilate It Right!

Light commercial models

COMMERCIAL HRV OPERATION AND INSTALLATION 69-COMHRV FD/DD, 650FD/DD, 700FD/DD, 1200FD/DD

GAS-FIRED UNIT HEATERS RESIDENTIAL, COMMERCIAL & INDUSTRIAL

TDSHS Air Change Requirements and the Basics of Psychrometrics. Presented by: Aric Murray December 06, 2013

Transcription:

EXHAUST FAN FLOW METER AND TRUEFLOW AIR HANDLER FLOW METER PERFORMANCE TESTING TOOLS MOST WIDELY USED DIAGNOSTIC TOOLS BY: Weatherization Auditors and Crews Home Performance Contractors Home Energy Raters Trainers

Exhaust Fan Flow Meter The Energy Conservatory s Exhaust Fan Flow Meter makes quick and accurate low flow measurements of airflow through residential bathroom fans, whole house ventilation fans and other exhaust devices. Smaller, lighter and easier to use than conventional flow measuring hoods, the Exhaust Fan Flow Meter is engineered to measure flow down to 10 CFM, with an effective range of 10 to 124 CFM. When placed over a fan grille, air is drawn through the calibrated opening. The opening is adjusted to minimize back pressure while maximizing accuracy. When used with our DG-1000 or DG-700 Digital Pressure and Flow Gauge, you can display air flow values directly in CFM. A handle with heavy duty Velcro fastener provides a secure connection to the Exhaust Fan Flow Meter. The threaded handle fits most standard painter s poles. The lightweight Exhaust Fan Flow Meter makes easy work of low flow airflow measurements. The pressure reading taken from the metering box can easily be converted to air flow using a flow table attached to the side of the metering box. Comes with a threaded handle that can attach to most painter s poles to reach highor ceiling- mounted grilles.

Parts of the Exhaust Fan Flow Meter Pressure tap Adjustable door Snap pin position holes Snap pin Rubber gasket Parts of the TrueFlow Air Handler Flow Meter Pressure sensing grid Metering holes Red and green tubing

TrueFlow Air Handler Flow Meter The Energy Conservatory s TrueFlow Air Handler Flow Meter provides a simple and accurate measurement of air flow through residential air handlers and filter grills. The TrueFlow plate temporarily replaces the filter in a typical air handler system to measure air flow. It can be installed in a filter slot directly adjacent to the air handler or remotely at a single central return grill. Other methods for estimating the air handler flow rate, such as the temperature rise method, static pressure and fan curve method, and the Duct Blaster isolated return method, have been found to be problematic or time-consuming. Extensive field testing has shown that the TrueFlow Measures flow through air handlers rated from one ton to five tons, 400 to 2,000 CFM. Works in a wide range of return plenum and air handler fan configurations. Is four times more accurate than the single point temperature rise method. Changes size quickly to fit standard and custom filter slots. Works with any manometer having a resolution of 1 Pa or 0.005 inches of water. Has a flow accuracy of ±7% for most applications when used with a 1% accurate pressure gauge. Direct cubic feet per minute (CFM) values are delivered in two to three minutes without extensive calculations. A variety of plate spacer sizes are available for the TrueFlow. When using these spacers, the TrueFlow will fit in most standard size filter slots. The carrying case included with the TrueFlow kit has a variety of pockets for keeping the plate spacers organized. The white gasket on the outer edge of the TrueFlow ensures a tight fit free of air leaks.

EXHAUST FAN FLOW METER SPECIFICATIONS FLOW ACCURACY ±10% of reading when used with a 1% accurate pressure gauge (such as a DG-700) with a display resolution of 0.1 Pa (0.0004 inches of water) FLOW RANGE Door position E1: 44-124 CFM Door position E2: 21-59 CFM Door position E3: 10-28 CFM DIMENSIONS (INSIDE) 16 in. L x 13 in. W x 8 in. D WEIGHT 3 lbs. including handle TRUEFLOW SPECIFICATIONS ACCURACY OF FLOW USING THE DG-700 OR DG-1000 DIGITAL PRESSURE AND FLOW GAUGE +\- 7% of indicated reading RANGE OF FLOW: #14 METERING PLATE 365-1,565 CFM (620-2,600 cmh, 172-740 l/s) RANGE OF FLOW: #20 METERING PLATE 485-2,100 CFM (825-3,570 cmh, 225-990 l/s) STORAGE AND OPERATING TEMPERATURE RANGE -40 F - 150 F (-40 C - 65 C) NOMINAL SIZES OF PLATES WITH GASKET MATERIAL CONNECTED: #14 METERING PLATE 14.5 x 20.5 (37 cm x 52 cm) NOMINAL SIZES OF PLATES WITH GASKET MATERIAL CONNECTED: #20 METERING PLATE 20 x 20 (50.8 cm x 50.8 cm) WEIGHT - METERING PLATES, SPACERS AND CASE 13 lbs (5.9 kg) COMPATIBLE FILTER SIZES WITH #14 METERING PLATE 14 x 20, 14 x 25, 16 x 20, 16 x 24, 16 x 25, 18 x 20 COMPATIBLE FILTER SIZES WITH #20 METERING PLATE 20 x 20, 20 x 22, 20 x 24, 20 x 25, 20 x 30, 24 x 24 Specifications subject to change without notice. Minneapolis Blower Door and TECTITE are trademarks of The Energy Conservatory. Duct Blaster and TrueFlow are registered trademarks of The Energy Conservatory. Stylized images of the Blower Door is also a Registered Trademark. For nearly 40 years, TEC products have been the first choice for energy raters, HVAC contractors, builders, insulation contractors, weatherization professionals and utility programs.

The Minneapolis Duct Blaster is used to measure the airtightness of ductwork. The Mini Fan Blower Door System uses the Duct Blaster fan and can be used to conduct blower door tests on small or tighter apartments and homes. The Minneapolis Blower Door is used to measure the airtightness of homes and buildings. COMPLETE SERVICE AND USER SUPPORT All of our products come with a full two-year warranty on parts and labor, and access to the most knowledgeable customer service staff in the industry. If you have questions on the use of our products or how to handle unusual situations, you can count on us to give dependable answers. We always stock a complete line of replacement parts and can respond quickly to any service or equipment problem. Our nearly 40 years of expertise goes beyond simply knowing about equipment. The Energy Conservatory s on-going research, active participation with technical associations, and close working relationships with the world s leading building scientists keeps us involved in the development and field testing of many of the performance testing industry s techniques. This means you always have the most up-to-date information and testing procedures. The most accurate Easy to use Dependable Backed by industry-leading tech support To order, or for more information contact: 2801 21st Avenue South Suite 160 Minneapolis, Minnesota 55407 Phone: (612) 827-1117 Fax: (612) 827-1051 info@energyconservatory.com energyconservatory.com 2017 The Energy Conservatory Updated 03/17