Viper 2.6 Viper deluxe

Similar documents
Operating manual ORKA & ORKA/CASE. a Look Solutions 1 product

Operating manual. Viper S USA. a Look Solutions 1 product

Operating manual. Viper nt. a Look Solutions 1 product

Operating manual. viper nt. a Look Solutions 1 product

Manual. base*highpower and. base*highpower*cased. hazebase, Uta Raabe

Operating manual. viper nt USA. a Look Solutions 1 product

TOUR-HAZER II Short manual

Operating manual UNIQUE UNIQUE [HAZER]

Operating manual. a Look Solutions 1 product

Operating manual UNIQUE 2.1. a Look Solutions 1 product

CFS-2000 CHILLER TM. Operating Instructions P/N (110 VAC) P/N (230 VAC)

Manual. Snow machine S-2

USER MANUAL. Version: 1.0. ROBE Show Lighting s.r.o. Czech Republic

Z-800II / Z-1000II / Z-1020 Fog Machine User Manual

Manual. Fazer DFZ-800

SNOBOX P/N (120 VAC) SNOBOX P/N (230 VAC)

Antari Low Fog Machine

LITTLE BLIZZARD XT LITTLE BLIZZARD XT/SP

Manual. Hazer DHZ-450

Antari X-310 ORDERCODE 60663

Z-350 Fazer Machine User Manual English

Fog 1550 FT USER MANUAL. Version: 1.2. ROBE Lighting s.r.o. Czech Republic

POLAR-CONTROLLER TM. Operating Instructions P/N (110 VAC) P/N (230 VAC)

DMX fog machine User manual

Z-1500II and Z-3000II USER MANUAL Z-1500II und Z-3000II BEDIENUNGSANLEITUNG Mode D Emploi des Z-1500II et Z-3000II Machines à Fumée

SF Owner s Manual FOG MACHINE. 1

Vivid Fogger Grey ORDERCODE Black ORDERCODE 60655B Orange ORDERCODE 60655O Red ORDERCODE 60655R Blue ORDERCODE 60655U Yellow ORDERCODE 60655Y

DMX fog machine User manual

USER MANUAL TRAINER 201

Antari Z-300 ORDERCODE 60661

HAZE 500 FT PRO USER MANUAL. Version: 1.2. ROBE Lighting s.r.o. Czech Republic

Magnum 650 Magnum 850 user manual P/N G

INDUCTION COOKER MODEL: EIC-G1810(BK) Owner s Manual. Please read this manual carefully before operating your set. Retain it for future reference.

Propane Flame Projector Safety instructions and operating manual

Magnum Internet Version. user manual P/N Martin Professional A/S

Steam Station User Manual

1Byone Products Inc. USER MANUAL 400 Watt Low Lying Fog Machine Model No.: O00QL-0045

Aerosol flame projector with spark effect Safety instructions and operating manual

PROLUX AIR PURIFIER / HUMIDIFIER MODEL: PL-2 Operation Instruction

MODEL NO RUSSELL HOBBS APOLLO 1.8L DIGITAL FILTER COFFEE MAKER

MD-MINI Dry Bath. Instruction Manual

FastGene Plate Centrifuge. Instruction Manual. Catalog No. NG

Table of Contents TABLE OF CONTENTS. Cumulus User Manual Rev. 4

Mobeye CM2410 GSM fire alarm communicator

PAC12J. 12,000btu Cool & Heat Portable Air Conditioner. Please read this manual carefully prior to operating the product.

ENGLISH Floodlight LED 50W

Warning: 230V / 1ph / 50Hz V / 3ph / 50Hz. Remarks: Make sure that you have enough power. (See page 15 Cable table)

GF-3000 Ground Fog Machine. user manual

V-PIX Vision Bar LED Pixel Bar Light. User Manual KEEP THIS MANUAL FOR FURTURE NEEDS

X T1220 LED FOG MACHINE USER MANUAL

PORTAL USER MANUAL. Mobeye WaterGuard-FS. Float sensor CM2300FS. SW version 5.n

Z-Stream Fog Machine User Manual English

CHESNEY S. Bio-Ethanol Installation & User Manual. model: EFB1200 with resevoir. Issue 01

POLAR-CONTROLLER TM. Operating Instructions P/N (120 VAC) P/N (230 VAC)

CHESNEY S. Bio-Ethanol Installation & User Manual. model: EFB1200. Issue 01

PAC12H. 12,000btu Cool & Heat Portable Air Conditioner. Please read this manual carefully prior to operating the product.

Operating Instructions. Accessory Units Melitta Cafina XT Series. Melitta Professional Coffee Solutions

Sunleaves Air Conditioner

2000 WATT CYCLONIC BAGLESS VACUUM CLEANER

ENGLISH Par W COB UV

HINTS AND TIPS Cleaning and maintenance HELPLINE

SPECIFICATIONS PART NAME

ELECTRIC FIREPLACE CONVERTER KIT OWNERS MANUAL Model Number: EF05-23

FT-50 Fire Training Fog Machine User Manual

Piccolo Cyclonic Vacuum Cleaner

Gallery Electric Fireplaces

PRACTICAL USER S GUIDE FOR THE DIMPLEX PURIFIRE ELECTRIC STOVE

HINTS AND TIPS Cleaning and maintenance HELPLINE

WET & DRY GARAGE VAC 20L CAPACITY WATT 1.5M MOTOR TANK STEEL HOSE KP702 ON BOARD ACCESSORY STORAGE SUCTION STAINLESS

READ CAREFULLY AND KEEP FOR FUTURE REFERENCE

Using the Remote Control Unit

Ui REFRIGERATOR SPEC SHEET

QTFX-900 mkii Fog Machine. Item ref: UK User Manual

DEHUM3 INSTRUCTION MANUAL SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE

UL U TR LTRASONIC S ONIC SCALE ALER PIEZO MINI

ELECTRIC STOVE HEATER Models: FS2213B

VADA - V80-H PRODUCT OVERVIEW CONSTRUCTION USAGE LIMITATIONS MOTOR WARRANTY

800W DMX smoke machine with HF remote control and Timer USER GUIDE December 2009 Version 1.0

FOR THE FOLLOWING MODELS: If you have any questions about the operation of your ultrasonic humidifier, please contact Crane Customer Care.

Tabletop Cooler. Installation and User Guide. Swan Service Helpline For model: SR12010 (all colours) SR12010_IM.indd 1 17/02/ :56

WALL MOUNT ELECTRIC FIREPLACE OWNERS MANUAL

SW-2 SNOW MACHINE. Item ref: UK User Manual

Installation & Operating Instructions

PORTABLE AIR CONDITIONER OWNER S MANUAL

ELECTRIC AIR PUMP 130W INSTRUCTION MANUAL SPECIFICATIONS. ozito.com.au WHAT S IN THE BOX. Electric Air Pump. 3 x Inflation Adaptors

WARNING FIRE DOOR CLOSING

Model No: Little Devil II (inc ss)

Full Size Canister Service Manual Riccar Models 1700 / 1800 Power Nozzles RPB-100 / RPB-220 / RPB-224 / RPB-250

Piranha Vacuum Cleaner

Electric Hand dryer. Installation and operating manual

PRACTICAL USER S GUIDE FOR THE contempra ef STOVE

USERS MANUAL FOR GAS BOILERS

INSTRUCTIONS AND WARRANTY

DZ5080 US Index01 19/09/07 10:50 Page 2

CONTROLS INSTRUCTIONS MANUAL ENGLISH

Pro6 Duo. Stampa Novaprint - Tel cod USER MANUAL

USER OPERATING MANUAL

Magnum 2500Hz user manual

OPERATIONS MANUAL. Hotplate Stirrer/Hotplate/Magnetic Stirrer Model HTS-1003/HTP-1002/MGS Certified

model No: ir20.v2 FUSE

Transcription:

Operating manual Viper 2.6 Viper deluxe a Look Solutions 1 product

Set of Equipment supplied 1 Viper 2.6 or Viper deluxe 1 tank lid with Quick Connector 1 manual Please check whether all the products you ordered are supplied. 2

Contents 1. Introduction 4 2. Safety instructions 5 3. Description of the parts 6 4. Fluid 8 4.1 General Notes 4.2 Changing the fluid container 5. Operating the Viper 2.6 8 5.1 Selecting the location 5.2 Putting into operation 5.3 Switching the device off 5.4 Control choices 5.4.1 Using a fan 5.4.2 Control via DMX 512 5.4.2.1 Adjusting the DMX start address 5.4.3 Control via 0-10 Volt (+) DC 5.4.4 Stand alone mode 4.4.5 Control via Radio remote 5.5 Operating with internal timer 5.5.1 Auto start 5.6 Wiring of the sockets 6. Cleaning, Care and Maintenance 16 7. Troubleshooting 17 8. Specifications 18 9. Warranty Conditions 19 3

1. Introduction The Viper 2.6 is a very powerful fog generator. It unites the current digital technology with proven technique and power. New features guarantee a much more simple operation place and fog, reducing the amount of time needed to set up the machine. An external fan with one phase and max. 800 watts scan be connected to the machine. 4

2. Safety instructions A fog machine is not a toy! Very hot steam escapes from the nozzle. Danger of getting burnt. Occasionally very hot droplets of fluid may escape when in operation. Thus never aim at persons directly and keep a minimum distance of 3 m to the nozzle. Never touch the nozzle when in operation. Danger of getting burnt. The location for the machine must be non-flammable, non-combustible and not sensitive to heat. It has to be twice as big as the machine. Keep a minimum distance of 60 cm to all flammable, combustible objects and objects sensitive to heat. Glycol is alcohol and burns with a slightly bluish, almost invisible flame. Never point the fog at strong sources of ignition like fire or pyrotechnic effects. Never open the machine and leave the machine unattended when connected to a power supply. The visibility has to be more than 2 m in rooms where people walk around. Do not swallow the fog fluid. Keep it away from children. In case of eye contact, rinse with a lot of water. Consult a doctor should you have accidentally swallowed some fluid. Spilled fluid or splashed fluid droplets can cause slip hazard. Mop up the fluid and dispose of it according to regulations. Fog may activate smoke detectors. Artificially-made fog can be produced in many different ways. The method used here to produce fog, with a device which works according to the vaporizer principle, is the most harmless one. No case has so far been reported in which a sound human being has been harmed because of using our device to produce artificial fog. However, this can only be guaranteed if the professional fog generators are used accordingly, i.e. at the correct vaporization temperatures as well as with the correctly mixed fog fluid. We, however, recommend: People with health problems or problems of the respiratory tract or with an inclination for allergies should avoid any contact with artificially-made fog. 5

3. Description of the parts Front view viper 2.6 Vapour and nozzle area extremelyhot Do not touch! 1 1: Nozzle Rear view 2 3 4 5 6 2: Fluid tube 3: Fluid tube inlet 4: Fuse for external fan 5: Socket for external fan 6: Mains cable 6

3. Description of the parts Top view 7 8 analog in dmx 512 Fuse : T5A This machine has been designed to Fan : max. 800W be used with waterbased glycol-fluid. Pin 1 : 25µF (brown) Use of other liquids will void the Pin 2 : life (black) manufacturer's warranty and can be Pin 3 : neutral (blue) dangerous to your health. viper 2.6 230V~/50Hz/2600W Serial no. Made by OTTEC Technology GmbH for Look-Solutions made in Germany 9 10 7: 8: 9: 10: Air vents DMX in/out Control panel for adjusting the DMX start address and the output XLR socket f. 0-10 V (+)DC Tank lid 11 12 13 14 15 11: 12: 13: 14: 15: Brass coupling Brass collar Tank lid Check valve Fluid filter 7

4. Fluid 4.1 General Notes The Viper 2.6 has been designed to be used with Look fog fluids. The following Look fog fluids are available: Quick-Fog Regular-Fog Slow-Fog thick, quick disappearing fog fluid thick, long lasting fog fluid thick, extremely long lasting fog fluid If fluids have been used other than Look fog fluids we can t grant warranty on parts that have been in contact with the fluid. 4.2 Changing the fluid can Disconnect the fluid tube from the lid by retracting the brass collar [12] and removing the coupling [11]. Remove the can from the tank housing of the Viper 2.6 Unscrew the lid [13] of the empty can and screw it onto the new container. Place the full can into the tank housing. Push the brass coupling [11] into the brass collar [12] until you hear a click.the brass collar is now locked firmly. 5. Operating the Viper 2.6 5.1 Selecting the location The location in which the Viper 2.6 is to be operated must be dry, be free from dusty or polluted air, be free from vibrations, be an non-flammable place or surface, be well-ventilated with fog-free air keeping the ambient operating temperature between 5 C and 45 C and the relative air humidity below 80%. 8

5. Operating the Viper 2.6 The Viper 2.6 is a powerful fog generator, producing every desired effect from a tiny puff of smoke to the thickest fog. Digital technology makes fine adjustments of the pump possible. In steps of 1% the output can be adjusted from 1-99%. 5.2 Putting into operation a. Connect the Viper 2.6 to the mains supply. Make sure the correct voltage is selected (230 V/50 Hz). A P and two figures appear on the display. P 2 5 b. After a warm up time of approx. seven minutes the Viper 2.6 is ready to start. The green Ready-Led [22] blinks if the working temperature is reached. As soon as the final temperature is reached, the LED illumates permanently. c. Adjust the required output via the control panel and press the Enter-button [18] once to start the fogging process (see point 5.4). 5.3 Switching the device off a. Press the Mode-button [16] til OFF appears on the display. After 15 seconds the machine will switch off automatically. On the right bottom edge of the display a red decimal point appear. You can also switch off the machine within these 15 seconds by pressing the Enter-button [18].. b. When you switch off the DMX signal, the machine will be switched off automatically after 15 seconds. 9

5. Operating the Viper 2.6 Control panel (Standard-Menu) P15 22: Ready-LED, green 21: Timer-LED, red 20: LED display 19: DMX-LED, yellow 18: Enter-button 17: Up/Down-buttons 16: Mode-button Abb. 1: Display shown at adjusting the pump output 275 Abb. 2: Display shown at adjusting the DMX start address F75 Abb. 3: Display shown at adjusting the fan output 10

5. Operating the Viper 2.6 OFF Abb. 4: Display shown at switching off the device 5.4 control choices Please note: The Mode-button can t be used for scrolling through the Menu. The Mode-button has to be pressed momentarily. If the Mode-button is pressed more than two seconds, the machine will change into the Timer-Mode (see point 5.5). 5.4.1 Using a fan A fan with one phase and max. 800 Watt can be connected to the machine. Therefore you need a special plug (Hirschmann Stas 3) which you can get from your local dealer. If you want to connect a fan with more than one phase you need a capacitor that can be build in the machine afterwards. Please ask your local dealer for details and specifications! Connect the plug of the fan to the socket [5] at the back of the machine. The fan can now be controlled as described (see point 5.4.2 to 5.4.4). The fan is already connected to the Viper deluxe and can be controlled as described on the following pages. The fan can be controlled separately and can be used as a wind machine. 11

5. Operating the Viper 2.6 You may control the Viper 2.6 externally through the XLR sockets [8 and 10]. Please note: DMX takes priority. That means: when the machine is controlled via DMX 512 this data takes priority over 0-10 V (+) DC and Stand alone operation. 5.4.2 Operating via DMX 512 Connecting the Viper 2.6 to a DMX-desk using the 5pin XLR socket [8] on the back of the machine. As soon as the machine receives a correct DMX signal, the yellow DMX-LED [19] shines. Now the pump and the fan can be adjusted via the desk. Please note: If a fan is connected to the machine, the Viper 2.6 uses two channels at your desk. Channel 1 = Pump, Channel 2 = Fan. 5.4.2.1 Adjusting the DMX start address a) Press the Mode-button [16] at the control panel, until three figures will appear on the LED display [20]. b) Adjust the requested start address by pressing the Up/Down-buttons [17]. c) Save the start address by pressing the Enter-button [18] once. The start address will also be saved when you disconnect the machine from the mains supply. 5.4.3 0-10 Volt (+) DC control Connect the Viper 2.6 to an analog desk or to the cable remote (available as an optional extra), using the 3pin XLR socket [10] at the back of the machine. Please note: With analog control the pump can be adjusted from the desk and/ or the cable remote. The fan has to be adjusted directly at the machine. a) Connect the cable from the desk or the cable remote into the 3pin XLR socket at the back of the machine [10]. b) The knob on the cable remote or the fader on the analog desk will control the level of the pump. c) Pressing the On/Off switch at the cable remote starts the fog process. To adjust the fan output a) press the Mode-button [16] until a F and two figures appear on the display [20]. b) Adjust the fan output with the Up/Down-buttons [17]. 12

5. Operating the Viper 2.6 5.4.4 Stand alone The Viper 2.6 can be used in the Stand alone mode. In this mode the control of the pump and the fan must be adjusted at the machine. a) Press and release the Mode-button [16] until a P and two figures appear on the display [20]. b) Adjust the pump output with the Up/Down-buttons [17] and press the Enterbutton [18] once to start the fogging process. The machine now produces fog until the Enter-button is pressed again. The output can be changed during the fogging process. To adjust the fan output a) press the Mode-button [16] again, until a F and two figures appear on the display [20]. b) Adjust the fan output with the Up/Down-buttons [17]. 5.4.5 Control via Radio remote A radio remote is available as an option. It will be delivered with a 3pin XLR plug. Connect the receiver of the radio remote to the machine, using the 3pin XLR socket [10] on the back of the machine. Adjust the requested pump output at the machine (see point 5.4.4). Press and hold the first button at the transmitter of the radio remote as long as you want fog to be produced (see manual Radio remote ). 13

5. Operating the Viper 2.6 Control panel Timer-Menu (the red Timer-LED [21] shines) P15 Adjusting of the output/pump in steps of 1% (1-99%) P01.. Adjusting of the wait time in minutes (0.1-99) F12. Adjusting of the fog time in seconds (1-99) ESC Escape to switch back to the Standard-Menue with the Enter-button 14

5. Operating the Viper 2.6 5.5 Operating the internal timer With the internal timer the fog time and wait time as well as the output can be adjusted. The output of the fan has to be adjusted in the Standard-Menue and can t be changed in the Timer-Menue. To start the Timer-Mode, press and hold the Mode-button [16] for more than 2 seconds. The red Timer-LED [21] shines as soon as the machine has switched to the Timer-Mode. As long as the timer is in operation, the red Timer-LED blinks. The adjusting of the output, fog time or wait time is the same as in the Standard-Menu. That means you have to press the Mode-button until you reach the required function. With the Up/Down-buttons you can adjust the output (Pxx), fog time (F.xx) and wait time (P.xx), then press the Enter-button to start the timer. The timer cycle starts with the time last shown on the display (P.xx = Starts with wait time, F.xx = Starts with fog time). You can switch back to the Standard-Menu by pressing the Mode-button [16] for more than 2 seconds or by switching to ESC (Escape) in the Timer-Mode and then press the Enter-button. 5.5.1 Auto start If the timer is in operation and you disconnect the machine from the mains cable, the Viper 2.6 will re-start in the Timer-Mode as soon as it s reconnected to the mains. To stop this press and hold the Mode-button [14] for more than 2 seconds or switch to ESC in the Timer-Mode and then press the Enter-button. 5.6 Wiring of the sockets 5pin XLR (DMX): Pin 1 = Ground, Pin 2 = DMX, Pin 3 = DMX + 3pin XLR (analog): Pin 1 = Ground, Pin 2 = 0-10 V + DC in, Pin 3 = 12 V + DC out, max. 50 ma 15

6. Cleaning, Care and Maintenance Ensure the air vents [7] are not clogged by dust. If necessary remove the dust. Take care that the machine can not get overheated. Do not run the Viper 2.6 without any fluid, as the pump will run dry. Wipe up spiled Fluid immediately. Moisture also fluid can destroy the electric of the machine. Check the state of the air valve filter from time to time and clean or replace it when necessary. When frequently using the same fluid can it should be cleaned thoroughly before adding new fluid. This reduces the chances of the machine clogging up. If you install the Viper 2.6 make 100% shure that a permanent fog-free air supply for the unit is guaranteed. Cooling air with too high fog concentration (very often in Clubs and Discos) can condense inside the machine and cause moisture damage. For cleaning the surface of the device use a suitable, solvent-free cleaner. PLEASE NOTE: It is not necessary to clean the vaporizer! Cleaning with any liquid/fluid can destroy the heat exchange module! 16

7. Troubleshooting The fog machine does not fog Check external control signals Check mains supply Check fluid tank (empty?) Check for correct connections at the fluid bottle Check for fluid in the fluid tube Check if fluid filter is clogged Check that pump setting on the machine is >1 The fog machine fogs uncontrollably Check mains supply Check unit for moisture (moisture inside the machine, especially on the PCB can cause fogging) The fog machine switches off suddenly The Temperature cutout has switched off due to overheating. Remove external heat source (for instance projector shining right onto the housing) and/or make sure sufficient fresh air supply. After 15 to 30 minutes the unit should switch back to on again. Loud droning sound during fogging The pump is running dry. Avoid this absolutely! Refill (or better: replace) fluid bottle Double check connection fluid tube and fluid bottle. E-4 appears on the LED display The machine is getting too hot. The heating switches off and the machine cools down. Solution: Disconnect the machine from the main supply for a moment and then re-connect it. E 4 E-1/E-2/E-3 appears on the LED display Please send the machine to the service-station or your local dealer. E 1 17

8. Specifications Fog generator Procedure: vaporizing fog generator Power requirement: 2600 Watt Voltage: 230 V/ 50 Hz Warm up time: approx. 7 min. Fluid consumption: at max. output 240 ml/min at cont. output 70 ml/min Fluid tank capacity: 5 Liter Fog output: adjustable in 99 steps, steps à 1% Output projection: max. 15 m Fogging time: at 100% output approx. 40 sec. at < 50% output continuous output external Fan: max. 800 Watt, fan with one phase Air quantity: adjustable in 99 steps Control: DMX 512 0-10 V analog Timer Stand alone mode Radio remote (Option) Temperature control: Microprocessor controlled Overheating protection: Heater block/thermostat Pump/Thermal switch Dimensions (L x W x H): 52 x 23 x 25 cm Weight without tank: 12 kg Look-Fan Procedure: Power requirement: Voltage: Air volume: Current: Capacitor (internal): Dimensions (LxWxH): Weight incl. Case: Centrifugal blower 355 Watt 230 V/ 50 Hz 1060 m3/h 1,55 A 8 µ / 450 VDB 22 x 19.9 x 21.6 cm 3.6 kg Viper deluxe Dimensions incl. Case (LxWxH): 75 x 42 x 77 cm Weight incl. Case: approx. 47 kg Manufactured for: Look Solutions made in Germany 18

9. Warranty Conditions For the fog machine Viper 2.6/Viper deluxe Look guarantee is: 1. Free of charge, subject to the following conditions (No. 2-6) we will repair any defect or fault in the unit if it is caused by a proven factory fault and has been advised immediately after appearance and within 24 month of delivery to the end user. Insignificant deviations of the regular production quality does not guarantee replacement rights, nor do faults or defects caused by water, wrong fog fluid, by generally abnormal environment conditions or Force Majeure. 2. Guarantee Service will be done in the following way: Faulty parts will be repaired or replaced (our choice) with correct parts. Faulty units have to be brought to us or our service centres or to be sent to us or our service centres at customer s expense. The invoice and/or receipt showing the purchase date and the serial number has to come with the faulty unit, otherwise this will not be guarantee service. Replaced parts become our property. 3. The customer loses all rights for guarantee services, if any repairs or adjustments are done to the units by unauthorized persons and/or if spare parts are used which are not approved by us. The right of guarantee service is also lost if fluids other than original Look fog fluids have been used or if units are sent to us with full fluid bottles. Also non compliance with the instructions in this manual or mistakes by incorrect handling/treating of the machine will lead to a loss of guarantee and also any faults and damages caused by undue force. 4. Certain parts of the machine are consumable parts and are not covered by the warranty. 5. Guarantee services do not cause an extension of the guarantee time or the start of a new guarantee time. The warranty for replaced parts ends with the guarantee time of the whole unit. 6. If a defect/fault can not be repaired by us in a satisfactory time, we will, within 6 months after sale of the unit, on choice of the customer, either: replace the whole unit for free or refund the lesser value or take back the whole unit and refund the purchase price, but not more than the usual market price at the time of the refund. 7. Further claims, especially for damages, losses etc. outside the unit are excluded. Other guarantee regulations may be valid outside Germany. Please check with your dealer! If you should send the unit for service, do not forget to remove any liquid from the fluid bottle. 19

a Look Solutions 20 product