V3000 KNX. KNX PID control system on water GENERAL DESCRIPTION

Similar documents
FLOWAY. Floway Range. The dual-flow air handling unit with heat recovery guaranteeing an Economical and Durable solution. use.

CLIMACIAT AIR COMPACT

MAGISTER. Compact and attractive design Energy savings with EC motor and self-regulating control. Easy to install. Use. Chilled water operation

The refrigerant circuit was studied in detail. Each step is verified, ensuring that each unit is perfectly leak-tight.

EXPAIR. Use. Precision air handling cabinets. Reducted footprint Dual-wall construction

CIATCOOLER LJA. Chilled water production units USE. Attractive design, Compact and quiet

Precision air-handling cabinets. CIATRONIC System Ultimate precision air-conditioning NA C

VEXTRA. acoustic comfort Saves up to. 40% floor space. Use. Range. Description. Drycoolers. Slim design and. Capacity up to kw.

HYDROCIAT LW R407C. Water cooled chillers USE RANGE

AGEO CALEO. Water-to-water high temperature heat pumps USE RANGE DESCRIPTION. Designed to replace a conventional boiler and produce domestic hot water

GeoCIAT Modular. Components. Heat pump Heating only, Glycol/water mix/water. Refrigerant and hydraulic module diagram. HomeConnect control.

Centrifugal air heaters hot water or electrical supply

AQUACIAT. Water chillers. Free cooling modules for AQUACIAT2 700V to 1100V AQUACIAT POWER 1200V to 1800V USE RANGE FREE COOLING

OPERA MORE. Use. Range. Drycoolers Air-cooled condensers. for LESS. Capacity: up to 1100 kw. Water misting. Free cooling

DRYPACK. Protecting installations Energy optimisation. Operating principle. Description. Biogas dehumidification system. Improved profitability.

ROOM THERMOSTATS KNX BASIC DOCUMENTATION

HOT AIR GENERATOR WITH GAS BURNER NA11.45 A GGS. Installation Operation Commissioning Maintenance

N M AirControl AHU. Control manual

Compact and silent Scroll compressors All-season operation

Split inverter air-to-water heat pump CERTIFIED BY CERTITA. option 30/35-40/45

TIREE FAN COIL CONTROLLER - T6580

ECOCIAT. Domestic hot water heat recovery unit. Use. Range

TopVent Design Handbook

Better Design, Better Control, Better Systems.

Installer Manual KNX Touchscreen Thermostat

T6580 FAN COIL CONTROLLER

CWX 6 - CWX 8 - CWX 10 CASSETTE TYPE TERMINAL UNIT

RVL471. Heating controller. G2524en. Installation Instructions. 1 Installation. 2 Commissioning

Hydronic & HVAC Control Systems

DUCTIMAX 2-8 kw. Medium available static pressure ducted hydronic units. Duct unit DUCTIMAX

VAV Thermostat Controller Specification and Installation Instructions. Model TRO24T4XYZ1

T7984 A,B,C Electronic Modulating Control Thermostats

TEC Controller Terminal Box Controller (VAV) - Series Fan Powered with Hot Water Reheat, Application Application Note

Application Sheet Fan coil unit with staged fan, 6-way heating/cooling coil (4 pipe) on analog output

control sequences model QST / EST Series Table 47: QST / EST Analog Electronic Control Strategies Fan Powered Air Terminals

Control solutions Biofloor

2017 products.koer.com Page 1 of 14

WINDOW YORK TECHNICAL GUIDE. Single package Cooling only and Heat pump. Models YO-YM R407C YO V6 G YO V7 G

CWX 3 - CWX 5 CASSETTE TYPE TERMINAL UNIT. Cooling

T7300F Multistage Conventional or Heat Pump Programmable Commercial Thermostat

39HX. High-efficiency dual-flow air handling unit PRODUCT SELECTION DATA. Plug & play unit (built-in control) Class A+ across entire range

Semi flush-mount room thermostat with KNX communications For VAV heating and cooling systems

CP CP

Room Temperature Controller

TEC Controller Terminal Box Controller (VAV) - with Hot Water Reheat, Application Application Note Building Technologies

Saving energy while ensuring an enhanced room climate

TEC Controller Unit Conditioner - Two-Pipe Fan Coil Cooling or Heating, Application Application Note Building Technologies

NA B AIR COMPACT. Instruction manual

User manual CLIMATIC 200/400 - Controller. Providing indoor climate comfort

Energy-efficient heat source provides comfort in large rooms

Application Sheet Chilled/heated ceiling (4 pipe) with 6-way valve on analog output

30GH Air-Cooled Liquid Chillers 30GH Nominal cooling capacity kw

ER65-DRW Controller. Heating Applications. Product Bulletin. Heating Controller

XE99 SERIES FAN-COIL THERMOSTATS 2-PIPE & 4-PIPE FAN-COIL CONTROL FEATURES APPLICATION PRODUCT SPECIFICATION SHEET

TEC210x-2 Series Networked Thermostats

Aquaciat Free cooling

Siemens Thermostats. RDY2000BN Thermostat

1 VICTRIX ZEUS Superior kw I features

CASSETTE UNIT. Comfort Circle

UDC100 Universal Digital Controller Specifications

DYNACIAT POWER. High energy efficiency Compact and quiet

T-Series Air Conditioner T20 Model

Product is subject to and complies with Regulation (UE) N.327/2011. cert. n Fan Coil Unit Cassette SkyStar Jumbo ECM. technical catalogue

SERVICE INSTRUCTION R410A. WALL MOUNTEDtype SPLIT TYPE ROOM AIR CONDITIONER INVERTER. Models Indoor unit Outdoor unit AO* R09LECN AO* R12LECN

NA G µair CONNECT 2

Document # R01

SIMPLICITY OR FULL MODULARITY?

Flush-mounted room thermostat

Technical Data Manual

TEC2100 Series Networked Thermostats

Comfort Compact Controller ZG 215VN

CONTROL OPTIONS SPACE HEATING APPLICATIONS MAKEUP AIR HEATING APPLICATIONS PEH, PXH, RDH, REH, RXH, SDH & SHH. Horizontal Split System- Models PDH,

Application Sheet Fan coil unit with staged fan, heating and cooling coil (4 pipe) on triac output including lighting and blinds operation

TopMaster Air Handling unit. Technical data

The ultimate in air handling units: directly and indirectly fired

HT V2 HT Split

AirTrak. Digital Control System. User Manual. Touchscreen Systems

User instructions DHP-AT

PACKAGED TERMINAL AIR CONDITIONER SOLUTIONS

AQUACIAT. Inverter Heat pump USE RANGE GRAND INVERTER

KPSW CONSOLE TERMINAL UNIT

SIMPLICITY FULL MODULARITY?

TEC Controller Heating & Cooling Heat Pump with Internal Reversing Valve & Mixed Air Control, Application 2072

T6984 A,D,E Electronic Floating Control Thermostats

Comfort Ceiling Fan Coil System INDULVENT ec. Draught-free ambient air distribution with cooling capacity up to 2600 W

Room thermostat with Auto Timer, independent DHW

T-Series Air Conditioner T15 Model

Semi flush-mount room thermostat

CLIMA I Thermostat ZENNIO

Series. Suspended air supply units with the air capacity up to 4100 m 3 /h in the sound- and heat-insulated casing with the water heater

Room thermostat with KNX communications RDG100KN

air handling units AT THE LEADING EDGE OF AIR FLOW

Fan Coil Thermostat Controller Specification and Installation Instructions. Model TFHB24F3XYZ1 with External Humidity Sensor and BACnet Communication

Heat Link. Technical Guide

ONX908PIT-V1-S1-F1/B Modulating Digital Thermostat

WOLF WARM AIR CURTAIN

The ultimate in air handling units: directly and indirectly fired

1 DOCUMENT REVISION CONTROL ELEMENTS... 9

NEW COMFORT UNITS Major Line. Sheer design sustainable innovation NA 09.73A

50CO. Close Control Unit. Wide range of chilled water cabinets. Compact and attractive design. EC motor for energy savings. Auto-adaptive control

Transcription:

KNX PID control system on water Wall terminal with dial Wall terminal with display Radio-frequency remote control Available in the second quarter of 2008 Factory-recessed thermostat New-generation networked control ariable-flow EE function control Control of condensation-free operation Many possibilities and innovative functions Designed and developed by CIAT GENERAL The 3000 is a networked electronic control designed by CIAT to control non-independent air conditioning terminal units (UTA and cassette-type fan coil units, etc.) operating in 2-pipe, 4-pipe, 2-pipe/2-wire systems using recirculated air. It actuates 24 three-position valves to control the water supply and thus ensures optimum control of ambient conditions. Unlike a thermoelectric motor, this type of motor can stabilise any valve opening from 0 to in accordance with the control system requirements. The 3000 controller is available as a flush-mounted version, factory-fitted to still-mounted fan coils, and a wall-mounted version requiring connection by the installer. A radio-frequency remote control is available for cases where wiring is not possible (renovations, etc.) The 3000 communicates over the international open KNX protocol (ISO 14543-3), allowing it to be completely interoperable with all other devices on your site. DESCRIPTION The 3000 uses Proportional-Integral-Derivative (PID) control to simultaneously operate an air conditioner s valves, electric heater and fan speeds. It comes with display or dial terminals to optimally adjust indoor comfort conditions. The factory-set control parameters (PID, deadband ventilation, etc.) can be adjusted on the display terminal. The 3000 can manage the Master/Slave functions via a Konnex bus (bus supply optional) if it is not connected to a BAS. The 3000 automatically controls CIAT s EE concept to improve the energy efficiency of CIAT s fan coil units: - Modulating output for adjusting the fan speed to room needs. - Automatic control of condensation-free operation for limiting losses caused by latent heat, etc. As an option, the 3000 can control the amount of incoming fresh air for 2-pipe and 4-pipe applications. For further information on how this control operates and the many configuration possibilites, please consult our documentation. 1

MAIN ADANTAGES Comparative adjustable valves TERMAL (time-proportional signal) KNX PID control system on water 0 Water flow rate, the valve is closed or open alve can get a stationary position between 0 to Discharge Discharge Office Office Energy savings 2000 3 POINTS (3000 PID signal) A 3-point actuator ensures a valve management close to the control needs, by the control of its stationary position between 0 and (control of the water flow rate). The blowing of the terminal unit will be more stable, and the office will get less variations (discomfort source). This stability not only permits to maintain optimal comfort but also to save energy too. The electricity consumption of the 3-point actuator is null when thermal balance is found contrary to the thermal valve. (Return on investment on energy saved: 2 to 3 years). The life span of a three-point motor is approximately 2 times higher than that of a thermic motor. To facilitate its servicing, the valve actuator is equipped with a plug-in connector. Electric coil management - 2-pipe/2-wire control algorithm (cooling + electrical heating or heating/cooling + electrical heating) eating / Cooling outlets - If hot water is present, the electric heater operates as shown by (a). electric (a) alve (b) 80% 50% alve - If hot water is not present, the electric heater operates as shown by (b). Outlet % 120% 0 80% 50% TC TF 50% 80% Xp Dead zone Xp Speed 3 t Base = 4 mn 2 Outlet % 120% 80% 50% 10% 0% 1 0 0% 10% 50% 80% t Base The controller simultaneously adjusts: - progressive opening or closing of the regulation valve, - time-proportional operation of the electric heater (max. 2800 Watt direct), - the three fan speeds or the fan stop. Priority is given to operation at low speed (medium speed is activated if the valve opening is greater than 80%). In ot / Cold + electric heater configuration, the electric heater only acts as a complement. If there is no hot water, the electric heater is triggered as soon as heating is needed. Note: the algorithm above assumes that the ventilation speed selector is in the automatic position and that ventilation is stopped in the dead zone. It only shows the proportional aspect. In reality Proportional Integral Differential control is used. The variation of the duty cycle permits modulating the electrical energy and thus having an operation mode, similar to the one of a progressive valve. If the user selects low speed manually, the electrical heating duty cycle is limited to 50%. If the medium speed is selected, the duty cycle limit will be 80%. This limitation allows to prevent overheating of the terminal unit. The controller can limit the duty cycle in function of the outside. TIMER The 3000 control integrates in standard a timer, adjustable from 1 minute to 24 hours. This function gives to the user possibility to switch on the terminal unit when he enters in his office. In that case, the switch off will be automatic (ex : 4 hours to manage morning and afternoon periods). t m 2

KNX PID control system on water RECIRCULATED AIR ONLY Kvs valves = 2.5 max - G 1/2 max. Maximum water flow rate: 1800 l/h CONTROL UNIT Factory-set and wired electronic PID controller Display terminal NP 16 bar valve with 24 three-position actuator Return air sensor fitted Fittings not included Terminal: - : flush-mounted, factory fitted Terminal: - : wall-mounted, to be wired by fitter Terminal: - S: wall-mounted, to be wired by fitter + supply air limit sensor. Ranges: all ranges except Cassettes, please consult us! MAJOR 2 - COADIS 2 UTA Compact With auxiliary pan, factory-fitted valves Fuse disconnect switch fitted MELODY cassette Without fuse disconnect switch and valve kit delivered separately S WATER CONTROL (24 /3-POS. ACTUATOR) 2-pipe system - eating only E3000 E3000 E047500 E047501 E047502 E3000S * E3001 E3001 E047520 E047521 E047522 E3001S - Cooling only E3002 E3002 E047500 E047501 E047502 E3002S * E3003 E3003 E047520 E047521 E047522 E3003S Automatic heating/cooling with changeover sensor fitted * E3005 E3005 E047560 E047561 E047562 E3005S 2-pipe system with electric heater (2300 W max.) - Cooling only + electric with dead band E3006 E047580 E047581 E047582 E3006 * E3007 E047600 E047601 E047602 E3007 - Automatic heating/cooling + electric heater with changeover sensor fitted * E3009 E047640 E047641 E047642 E3009 - Additional charge for a capacity of 2000 W to 4600 W. E038556 4-pipe system > 2 two-way valves E3040 E3040 E047660 E047661 E047662 E3040S > 2 two-way valves* E3041 E3041 E047680 E047681 E047682 E3041S Mandatory additional charges for valves with Kvs> 2.5 Additional charge for 1 x 2-way valve, 3/4 Kvs 2.5 or Kvs 4 E038563 Additional charge for 1 x 4-way valve, 3/4 Kvs 2.5 or Kvs 4 E038571 Recommended commissioning support Callout charge (mainland France) E002003 E002046 + Additional service charge per unit * 3-way valve(s) with by-pass. ALL-ELECTRIC AND RECIRCULATED AIR ONLY OPERATION CONTROL UNIT: 3000 controller set for all-electric and recirculated air only operation UTA STANDARD Terminal: : flush-mounted, factory fitted and wired 6R or 9R Terminal: : wall-mounted, to be wired by installation technician - 1 power supply (1-ph, 230, 50 z, 2000 W max.) E3050 E3050 E047760-2 power supplies / ventilation (1-ph, 230, 50 z) E047770 E3055 E3055 - Electric heater (1-ph, 230, 50 z, 2000-6900 W max.) - 2 power supplies / ventilation (1-ph, 230, 50 z) E047780 E047781 (1) E3060 E3060 - Electric heater (3-ph, 400, 50 z, 2000-16800 W max.) (1) Power limited to 16800 W: all sizes of with 6 rows and size 370-22 with 9 rows Note: the prices for a dial room terminal are the same as those for a display terminal. Please specify the desired type of terminal at time of order. Dial terminal available in wall-mounted version only. 3

RECIRCULATED AIR ONLY KNX PID control system on water Less cost for display room terminal MAJOR 2 COADIS 2 UTA Compact LESS COST FOR ROOM TERMINAL E039097 MELODY cassette OPTIONS and ACCESSORIES 7161243 Wall-mounted room terminal with dial Blank terminal with sensor No dial or buttons / intended for use in buildings open to the public 7161242 7161247 Radio-frequency remote control (controls up to 8 3000) E038550 Radio-frequency receiver (one receiver per unit required) Delivered pre-wired. Konnex bus power supply 160 ma for 64 x 3000 max. Please refer to our documentation for information on using a KNX bus Consult us 4

KNX PI control system for fresh air APPLICATION: CONTROL AT CONSTANT DISCARGE AIR TEMPERATURE Example application for modular offices COADIS CASSETTE for control ambient UTA STANDARD with motorised damper flap WALL TERMINAL with ambient sensor The purpose of this control is to introduce fresh air at a constant into a room with its own terminal unit which controls the ambient. Inspired by a recycled air system, the controller also operates the fresh air inlet valve on the terminal unit (UTA STANDARD with air box and servo-motor in the example shown). The unit operates at a single speed (to be specified when ordering), corresponding to the fresh air flow rate to be introduced. The controller works progressively depending on the blown air using a proportional algorithm. A heating or cooling cycle is triggered based on the heating and cooling setpoints. In comfort mode, the inlet flap is open. If stop mode is activated, or in the event of a power cut, the flap is closed. The risk of freezing is determined either by a signal from the frost protection thermostat or if the valve is fully open (insufficient thermal capacity and thus risk of freezing). If a risk of freezing is detected, the flap is closed, the fan stops immediately and the valve remains open. Note that air extraction must correspond to air intake in the room to be conditioned. Note: not compatible with electrical application. See our manuals for further details about the operation and multiple possible parameter settings of these controllers. FRES AIR CONTROL UNIT: Configured 3000 controller Display terminal / 3-position 4-way valve (NP: 16 bar) / Ancillary pan and fuse disconnect switch Control relay for air blade actuator and frost protection thermostat CONSTANT SUPPLY AIR TEMPERATURE CONTROL Room terminal: - : flush-mounted, factory fitted and wired - : wall-mounted, to be wired by installation technician 2-pipe system - eating only E047700 E047701 ANB3001 ANB3001 - eating/cooling with changeover sensor fitted E047710 E047711 ANB3005 ANB3005 4-pipe system > 2 four-way valves ANB3041 ANB3041 E047720 E047721 Consult us Mandatory additional charges for valves with Kvs greater than 2.5 For size 370/66 UTA E038571 Additional charge for 1 x 4-way valve, 3/4 with Kvs of 4 Note: a damper and a damper actuator are needed in addition to the terminal unit. 5

KNX PI control system for fresh air APPLICATION: ROOM TEMPERATURE CONTROL WIT CASCADED ROOM AIR / DISCARGE AIR Application example for restaurant dining rooms or meeting rooms Discharge air grille 2000 Fresh air intake grille Recycled air intake UTA STANDARD with motorised damper flap The purpose of this control is to introduce fresh air and control the ambient in a room. Inspired by a recycled air system, the controller also operates the fresh air inlet valve on the terminal unit (UTA STANDARD with air box and servo-motor in the example shown). The unit operates at two speeds, and the controller works depending on the ambient sensor using a Proportional Integral algorithm. In automatic ventilation, the controller progressively controls the valve while simultaneously adjusting the fan speed. With a manual speed setting, the controller controls the valve only. In heating mode, if the blown air is lower than the blown air setpoint, the controller gives priority to the blown air sensor. In cooling mode, the controller operates depending on the ambient sensor only. In comfort mode, the intake flap is open. In economy or frost protection mode, or if power is cut, the intake flap is closed and the controller maintains the setpoint in total air recycling. In stop mode, the room is protected against frost. The risk of freezing is determined either by a signal from the frost protection thermostat or if the valve is fully open (insufficient thermal capacity and thus risk of freezing). If a risk of freezing is detected, the flap is closed, the fan stops immediately and the valve remains open. Note that air extraction must correspond to air intake in the room to be conditioned. Note: not compatible with electrical application. Consult our manuals for further details about the operation and multiple possible parameter settings of these controllers. FRES AIR CONTROL UNIT: Configured 3000 controller Display terminal / 3-position 4-way valve (NP: 16 bar) / Ancillary pan and fuse disconnect switch Control relay for air blade actuator and frost protection thermostat TEMPERATURE CONTROL WIT ROOM/SUPPLY AIR CASCADE CONTROL Room terminal: : wall-mounted, to be wired by fitter 2-pipe system - eating only E047730 E047731 ANA3001 - eating/cooling with changeover sensor fitted ANA3005 E047740 E047741 4-pipe system > 2 two-way valves ANA3041 E047750 E047751 Consult us Mandatory additional charges for valves with Kvs greater than 2.5 For size 370/66 UTA E038571 Additional charge for 1 x 4-way valve, 3/4 with Kvs of 4 Note: a damper and damper actuator are needed in addition to the terminal unit. 6

This document is non-contractual.as part of its policy of continual product improvement, CIAT reserves the right to make any technical modification it feels appropriate without prior notification. ead office Avenue Jean Falconnier - B.P. 14 01350 - Culoz - France Tel.: +33 (0)4 79 42 42 42 - Fax: +33 (0)4 79 42 42 10 info@ciat.fr - www.ciat.com CIAT Service Tel.: +33 (0)4 79 42 42 90 - Fax: +33 (0)4 79 42 42 13 Compagnie Industrielle d Applications Thermiques - S.A. with a registered capital of 26 000 000 - R.C.S. Belley B 545 620 114