A Fresnel Reflection-Based Optical Fiber Sensor System for Remote Refractive Index Measurement Using an OTDR

Similar documents
Long-Range Displacement Sensor Based on SMS Fiber Structure and OTDR

OPTICAL TIME DOMAIN REFLECTOMETRY (OTDR) Dr. BC Choudhary Professor, NITTTR, Chandigarh

Experiment Study in Optical Fiber Temperature Monitoring

Omnisens DITEST TM FIBER OPTIC DISTRIBUTED TEMPERATURE & STRAIN SENSING TECHNIQUE

FACULTY OF ENGINEERING LAB SHEET OPTICAL COMMUNICATION SYSTEMS EOP4066 TRIMESTER 1 (2013/2014)

LAB REPORT SUBMISSION COVER PAGE ETN4106 OPTOELECTRONICS AND OPTICAL COMMUNICATIONS

OPTICAL TIME DOMAIN REFELECTOMETER (OTDR): PRINCIPLES

Interferometric optical time-domain reflectometry for distributed optical-fiber sensing

We are IntechOpen, the world s leading publisher of Open Access books Built by scientists, for scientists. International authors and editors

Fiber optic distributed pressure sensor for structural monitoring applications

Optical Time Domain Reflectometry (OTDR)

Harmful Intrusion Detection Algorithm of Optical Fiber Pre-Warning System Based on Correlation of Orthogonal Polarization Signals

High-resolution Photon Counting-OTDR Based Interrogation of Multiplexing Broadband FBG Sensors

Two-Pipe Fiber Bragg grating Temperature Sensor Applied in Cable Trench and Cable Pit

The Optical Time Domain Reflectometry and the Fusion Splicer Laboratory exercise

Field Test Procedure for Optical Fibre Link Measurements

Fibre Optic Basics FIA Summer Seminar 2014

GAMMA OTDR application consists of main window and menu. Using menu user can operate in different modes of application.

Correlation-based OTDR for in-service monitoring of 64-split TDM PON

Journal of Applied Science and Agriculture. Improve the Spatial resolution of distributed optical sensors by designing a new detection scheme

PC474 Lab Manual 1. Terry Sturtevanta and Hasan Shodiev 2. Winter 2012

Optical Return Loss Measurement by Gregory Lietaert, Product Manager

Long-distance remote simultaneous measurement of strain and temperature based on a Raman fiber laser with a single FBG embedded in a quartz plate

Detection of Solvents using a Distributed Fibre Optic Sensor

Distributed Rayleigh scatter dynamic strain sensing above the scan rate with optical frequency domain reflectometry

Integrated optical fiber shape senor modules based on twisted multicore fiber grating arrays

WHITE PAPER FIBER OPTIC SENSING. Summary. Index. Introduction. About Fischer Connectors

PC474 Lab Manual Wilfrid Laurier University 1

RAMAN SCATTERING AND OTDR BASED DISTRIBUTED SENSOR FOR TEMPERATURE MONITORING APPLICATIONS

Introduction to Fiber Optic Sensing

OSEN - Optical Fiber Sensor Technologies

ANALYSIS OF OTDR MEASUREMENT DATA WITH WAVELET TRANSFORM. Hüseyin ACAR *

AV6419 BOTDR. Product Overview. Main Features

OTDR - FHO5000-xxx. Optical Time Domain Reflectometer

Open Access Operation Modes and Energy Analysis of a New Ice-Storage Air- Conditioning System

Carlos Borda Omnisens S.A. Subsea Asia Conference June 2014

Reflectance, The Hidden Danger That Increases Bit Error Rates in Your Fiber Networks Denver, May 22nd, 2010

Luna Technologies Webinar Series. New Rayleigh-Based Technique for Very High Resolution Distributed Temperature and Strain Sensing

Link loss measurement uncertainties: OTDR vs. light source power meter By EXFO s Systems Engineering and Research Team

Research on the Monitor and Control System of Granary Temperature and Humidity Based on ARM

Chapter 1. Introduction

Distributed Temperature Sensing

DEGRADATION OF OPTICAL FillERS AT CARBON-CARBON PYROLYSIS. Rockwell International Science Center P.O. Box 1085 Thousand Oaks, CA 91358

Design of Humidity Monitoring System Based on Virtual Instrument

STRUCTURAL HEALTH MONITORING OF UNDERGROUND INFRASTRUCTURE

Oil and Gas Pipeline Monitoring. Oil and Gas Well Monitoring. Power Line Monitoring. Highway Safety Monitoring

DWDM OTDR with Tunable Laser MTP-200-D100. Hand-held High Performance OTDR. Series

M310 Enterprise OTDR. Designed for Enterprise Network Testing, Troubleshooting and Documentation. or (800) , (603)

Fli'l HEWLETT. Measurement of Raylelgh Backscattering at 1.55 urn with a 32 um Spatial Resolution

High cost performance choice

Optical Fiber Sensing Technology: Basics, Classifications and Applications

Locating bad PMD sections with a Polarization-OTDR

RSL Fiber Systems, LLC

Noyes OFL 250B Specs Provided by

Development of optical fiber sensors for selected chemical and physical sensing applications

SOLUTION MINING RESEARCH INSTITUTE

Performance of a Distributed Simultaneous Strain and Temperature Sensor Based on a Fabry-Perot Laser Diode and a Dual-Stage FBG Optical Demultiplexer

AN EXPERIMENTAL INVESTIGATION OF THE SENSITIVITY OF A BURIED FIBER OPTIC INTRUSION SENSOR. A Thesis HARINI KUPPUSWAMY

A Method for Fire Detecting by Volume and Surface Area Concentration Based on Dual Wavelengths

M700-Series Multifunction OTDR

Computerised Analysis of OFM in Communication Theory

palmotdr Series Handheld OTDR

High Spatial Resolution Distributed Fiber Optic Technique for Strain and Temperature Measurements in Concrete Structures

DETECTION AND LOCALIZATION OF MICRO AND MULTIPHASE LEAKAGES USING DISTRIBUTED FIBER OPTIC SENSING

Fiber Optic Sensor technology for Non-optical parameter measurement

FLX380-30x FlexTester OTDR

Principle and Application of Fiber Optic Scattering Sensors Il-Bum Kwon

A Cost Effective Multi-Spectral Scanner for Natural Gas Detection

Optical Time-Domain Reflectometry for the Transport Spatial Filter on the OMEGA Extended Performance Laser

Multitel develops components and full instruments for in-vitro and in-vivo diagnostics in the biomedical, food and drug sectors.

VIEW500 USER-FRIENDLY STANDARD OTDR

AV6416 OTDR. Product Overview: Main Features:

High cost performance choice

Agilent E6000A E6003A Specs Provided by E6000C Mini-OTDR. Technical Data Sheet

Fiber optic system for monitoring large earth structures

VTI Services Technical Bulletin (TB) OTDR Measurement of Installed Optical Fibre Cabling Permanent Links and Links

This document is downloaded from DR-NTU, Nanyang Technological University Library, Singapore.

Design of the Fiber-optic Fence Warning System with Distributed Video Real-Time Display Function Qiang-yi YI and Zheng-hong YU *

Benefits of Enhanced Event Analysis in. Mark Miller

MINI2. Inno Mini 2 Specs Provided by MOST ACCURATE COMPACT OTDR

FIBER OPTIC TESTING 1

Optical Fibres ELEC8350

Hybrid fibre optic sensor network for real-time high temperature performance monitoring of steel structures

Table of Contents. Introduction... 1 Fiber Optic Communications... 1 Testing Optical Fiber For Loss... 2 Other Fiber Tests... 2 OTDR Applications...

Recent Progress in Lightwave Sensing Technology

TSI AEROTRAK PORTABLE PARTICLE COUNTER MODEL 9110

Distributed sensing based on reflections and Rayleigh backscatter. Brian Culshaw University of Strathclyde Glasgow Scotland

M210 Multifunction Micro OTDR

Detection system for optic characteristics of automobile glasses

FTTH NETWORK TESTING: REAL APPLICATIONS USING THE OLTS METHOD

gathering and maintaining the data needed, and completing and reviewing the collection of information. Send comment

SECTION 1: STARTING 1.1 UNPACKING AND INSPECTION

palmotdr Series Handheld OTDR

M210 Multifunction Micro OTDR

Fire Control Panels. Multiple Signal Fiber Optic Modems and Accessories for Panel and Remote Mounting. Features. Operation.

Beam Loss Position Monitoring with Optical Fibres at DELTA

Agilent E6012A Specs Provided by E6000C Mini-OTDR. Technical Data Sheet

Research Article Development of the Noncontact Temperature Sensor Using the Infrared Optical Fiber Coated with Antifog Solution

Ensuring Cabling Performance in the Customer-Owned Outside Plant. Keith Foord Product Manager Greenlee Communications

Characterization of High Speed Optical Detectors for Purpose of OM4 Fibre Qualification: Selective Mode Detection

Transcription:

PHOTONIC SENSORS / Vol. 4, No. 1, 2014: 48 52 A Fresnel Reflection-Based Optical Fiber Sensor System for Remote Refractive Index Measurement Using an OTDR Jianying YUAN, Chunliu ZHAO *, Manping YE, Juan KANG, Zaixuan ZHANG, and Shangzhong JIN Institute of Optoelectronic Technology, China Jiliang University, Hangzhou, 310018, China * Corresponding author: Chunliu ZHAO E-mail: zhchunliu@hotmail.com Abstract: In this paper, we propose a Fresnel reflection-based optical fiber sensor system for remote refractive index measurement using the optical time domain reflectometry technique as an interrogation method. The surrounding refractive index from a long distance away can be measured easily by using this sensor system, which operates based on testing the Fresnel reflection intensity from the fiber-sample interface. This system is a simple configuration, which is easy to handle. Experimental results showed that the range of this measurement could reach about 100.8 km, and the refractive index sensitivities were from 38.71 db/riu to 304.89 db/riu in the refractive index (RI) range from 1.3486 to 1.4525. Keywords: Fresnel reflection, optical fiber sensor, remote measurement, OTDR Citation: Jianying YUAN, Chunliu ZHAO, Manping YE, Juan KANG, Zaixuan ZHANG, and Shangzhong JIN, A Fresnel Reflection-Based Optical Fiber Sensor System for Remote Refractive Index Measurement Using an OTDR, Photonic Sensors, 2014, 4(1): 48 52. 1. Introduction Remote monitoring is useful and important for some applications such as chemical industry, marine environments assessment, and pipeline monitoring, and the refractive index (RI) is an inherent characteristic of a substance that is closely related to the physical and chemical properties, hence, a precise detection of the RI is essential in some remote fields [1, 2], for example, the remote monitoring of the refractive index or solution concentration in some dangerous chemical industry is highly necessary for the safety production. Recently, Fresnel reflection-based optic sensors have attracted general interest due to their simple structure, low cost, low cross infection, and durability against the harsh environment [3 5]. In 2013, M. G. Shlyagin et al. [6] proposed an optical fiber refractometer based on the Fresnel reflection in the fiber tip, in which a twin-bragg grating interferometer is located at some distance from the fiber tip to eliminate the influence of light source fluctuation and environment. Such a structure is complex and not suitable for a remote measurement. In this paper, we propose a remote refractive index sensor based on Fresnel reflection that can timely tell the RI value from a long distance away, meanwhile, the position of the testing point can be obtained by using a commercial optical time domain reflectometer (OTDR). The theory analysis and experimental setup of the design are introduced and discussed in detail. The experimental setup is simple, which is easy to handle. Experimental results showed that the proposed remote measurement sensor worked well and had a good stability, the sensitivities were from 38.70 db/riu to Received: 17 July 2013 / Revised version: 11 October 2013 The Author(s) 2013. This article is published with open access at Springerlink.com DOI: 10.1007/s13320-013-0131-6 Article type: Regular

Jianying YUAN et al.: A Fresnel Reflection-Based Optical Fiber Sensor System for Remote Refractive Index Measurement Using an OTDR 49 304.73 db/riu in the RI range from 1.3486 to 1.4525. 2. Setting and sensing principle Figure 1 shows the experimental setup of the proposed remote surrounding refractive index (SRI) sensor. The system includes an optical time domain reflectometer (OTDR) and a long distance single mode fiber whose end is cleaved as a vertical smooth surface which is used as a sensing head. Glycerol solutions with different concentrations are used as the testing samples whose RIs have been calibrated by the Abbe refractometer. Laser pulse Fiber Reflection Sample OTDR Fig. 1 Experimental setup of the solution concentration sensor. As shown in Fig. 1, laser light pulses (the wavelength is 1550 nm, and the averaging time is 60 s) from the OTDR are emitted into the fiber link, when they reach the interface between the fiber s end surface and sample, Fresnel reflection signals go backward, whose intensities are corresponding to the SRI, then the Fresnel reflection signal and backscattering light signals will be detected by the OTDR (FTB-150), which can be able to resolve intensity changes in backward signals of 0.01 db. The OTDR system is normally used for the characterization of optical fiber links, it operates by periodically emitting short duration laser pulses into the fiber link, and the backscattering light signal and the Fresnel reflection signal are detected and analyzed by the OTDR computing system. Finally, the backscattering signal and the Fresnel reflection signal levels can be shown on the OTDR trace. In short-distance measurements, the transmission loss of the optical fiber is so low that won t make much difference to the results, however, a long length optical fiber is used in this remote measurement, thus the transmission loss of the long fiber link cannot be neglected. From different distances, the detected intensity values of reflection signals are not equal, so the intensity of the reflection signal is not suitable to be used as an indicator for measuring the RI. Here, we choose the relative intensity as the indicator [7]: Iout ( λ) ncore ns 2 R = = ( ) (1) Iin ( λ) ncore + ns where I out is the intensity of the Fresnel reflection light from the fiber-sample interface, I in is the input intensity of the laser light, and n core and n s are the reflective index (RI) of the fiber core and that of the sample under test, respectively. n core is a constant (be taken as 1.467 at the room temperature 25 ) which is determined by the physical parameter of the fiber. R in db is also the height of the reflection peak on the OTDR trace as marked in Fig. 2. We can measure the surrounding refractive index from a (a) (b) Fig. 2 Enlarged views of two reflection peaks when sensing heads are located at the distances of (a) 50.4 km and (b) 100.8 km, respectively.

50 Photonic Sensors measurement of the height value of the reflection peak on the OTDR trace. 3. Experiment and results We utilized this sensor system to make two remote SRI measurements in which the testing solutions were located at 50.4 km and 100.8 km away, respectively. The experiments were carried out within two laser pulse widths, the 1-μs width [Fig. 2(a)] and 2.5-μs width [Fig. 2(b)] for 50.4-km and 100.8-km SRI measurements, respectively. As shown in Fig. 2, it can be seen that every trace has its clear reflection peak, and the height of each reflection peak decreases monotonically with an increase in the refractive index. Figure 3 shows the relationship between R and SRI for the 50.4-km and 100.8-km SRI measurements. Experimental data show that two existing results are in a good agreement with each other, so that two results can use one curve to fit them. The fitting function is y = 10.124 lg [(1.467 x) / (1.467+x)] + 23.771 with fitting degrees of 0.9993 and 0.9984 for the 50.4-km and 100.8-km SRI measurements, respectively. In the fitting function, x and y are in the corresponding to SRI and R in db, respectively. We can get the sensitivity through the derivation of the fitting function. The refractive index RI sensitivities for this sensor system were from 38.70 db/riu to 304.73 db/riu in the RI range from 1.3486 to 1.4525. The OTDR with a 0.01 db measurement precision was used in our experiments, so the Fig. 3 Relationships between the relative intensity and refractive index for the 50.4-km test and the 100.8-km test. precision of the RI could reach about 2.58e 4 in the RI value of 1.3486 in theory. Further, the ambient temperature effect on the refractive indices of fiber cores needs to be considered, which will affect the results of the measurement. The thermo-optic coefficient of the optical fiber is about 6.45 10 6 / at the wavelength of 1550 nm, thus the maximum error of R can be calculated according to (1). The maximum error is about 0.045dB with the temperature change in the range of 0 100, when the value of n s is assumed as 1.3486. Thus, the resolution of the system is affected by the temperature change and is limited at about 1.0e 3 when the OTDR with the intensity resolution of 0.01 db is used in our experiments. But when the proposed sensor works in the temperature change less than 30, the measurement error caused by the temperature effect will decrease to below 1.0e 4 and can be neglected at times. For remote applications, the attenuation or loss of light caused by fiber-bending, strains and stresses in the fiber link is an important issue, which will affect the results of the measurement. We investigated the system s repeatability and accuracy by repeating the test with a length of the fiber link as 100.8 km, in which the samples true RI values were 1.0000 and 1.4043, respectively. In addition, we applied a stress on the position of about 50.4 km in the fiber link, which caused a loss in the middle of the fiber link. The output OTDR traces of these measurements are given in Fig. 4. As it can be easily observed from Fig. 4, there is a step loss in the middle position of the dotted lines, which is about 1.4523 db. After this position, the intensity of light back scattered and the height of the reflection peak for the measurements decrease with certain attenuation, and the differences between two curves are almost equal to the step loss. For these measurements, the measured relative intensities and the calculated RIs are given in Table 1. The calculated RIs are obtained through substituting these measured height values into the above

Jianying YUAN et al.: A Fresnel Reflection-Based Optical Fiber Sensor System for Remote Refractive Index Measurement Using an OTDR 51 mentioned fitting function. (a) (b) Fig. 4 Output OTDR traces when sensing heads are inserted in (a) air and (b) a sample whose RI is 1.4043: the insets show the enlarged views of two reflection peaks. Table 1 Measured relative intensities and the calculated RIs. No stress Under stress Samples Calculated Measured Calculated Measured R RI R RI Air (n=1.0000) 16.446 1.0006 16.448 1.0004 Glycerol (n=1.4043) 6.953 1.4044 6.955 1.4043 As Table 1 implies, the measured relative intensity R remains constant with or without a stress in the fiber link for the same sample. By comparing the true values in Table 1, the calculated values have reached the very high accuracy. The maximum error is about 6e 4. This means that the measurement error caused by the bending loss or stress in the fiber link is negligible. It can be also deduced that the laser power fluctuation has almost no effect on the results by using this method, as well as the usage of connectors which can be treated as a loss along the fiber. Hence, the proposed RI remote measurement sensor can realize the remote measurement with a good stability and can be a good candidate for some remote applications. In this system, the average fiber loss was about 0.186 db/km, and the OTDR dynamic range was about 23 db when the measurement range of the OTDR was selected to be 160 km, so the sensing range could reach about 124 km. When the measurement range of the commercial OTDR we used in the system was selected to the maximum (260 km), the OTDR dynamic range was about 30 db, so the maximum sensing distance of the setup could approach about 161 km. The measurement range of the system was determined by the fiber loss, OTDR s dynamic range, spatial resolution, detection sensitivity, and length of the fiber link. Certainly, the system could be improved by using a higher performance commercial optical time domain reflectometer. Moreover, cascading some optical amplifiers can help to achieve a further monitoring [8 10]. 4. Conclusions A simple Fresnel reflection-based optic fiber sensor has been proposed for the remote refractive index measurement. It operates based on the Fresnel reflection from the interface between the sensing head and sample and use the optical time domain reflection technique as an interrogation method. Such a spot-measuring method can avoid the cross infection between samples effectively. The proposed sensor system has been proved through our measurements that it has a good stability and can be a good candidate for the remote RI monitoring. Acknowledgement This work was supported by the National Natural Science Foundation of China under Grant No. 61108058, the National Basic Research Program of China (973 program) under Grant No.

52 Photonic Sensors 2010CB327804, the National Key Technology R&D Program 2011BAF06B02, the Science and Technology Commission of Shanghai Municipality of China under Grant No.10595812300, and The Program Funded by Scientific Research and Innovation Team of College Students in Zhejiang Province. Open Access This article is distributed under the terms of the Creative Commons Attribution License which permits any use, distribution, and reproduction in any medium, provided the original author(s) and source are credited. References [1] H. Minnato, Y. Kakui, A. Nishimoto, and M. Nanjo, Remote refractive index difference meter for salinity sensor, IEEE Transaction on Instrumentation and Measurement, 1989, 38(2): 608 612. [2] M. Bravo, J. M. Baptista, J. L. Santos, M. Lopez-Amo, and O. Frazão, Ultralong 250km remote sensor system based on a fiber loop mirror interrogated by an optical time-domain reflectometer, Optics Letters, 2011, 46(20): 4059 4061. [3] J. R. Zhao, X. G. Huang, W. X. He, and J. H. Chen, High-resolution and temperature-insensitive fiber optic refractive index sensor based on Fresnel reflection modulated by Fabry-Perot interference, Journal of Lightwave Technology, 2010, 28(19): 2799 2803. [4] C. L. Zhao, J. H. Li, S. Q. Zhang, Z. X. Zhang, and S. Z. Jin. A simple Fresnel reflection-based optical fiber sensor for multipoint refractive index measurement using an AWG, IEEE Photonics Technology Letters, 2013, 25(6): 606 608. [5] J. H. Chen and X. G. Huang, Fresnel-reflection -based fiber sensor for on -line measurement of ambient temperature, Optics Communications, 2010, 283(9): 1674 1677. [6] M. G. Shlyagin, R. M. Manuel, and Ó. Esteban, Optical-fiber self-referred refractometer based on Fresnel reflection at the fiber tip, Sensors and Actuators B, 2013, 178: 263 269. [7] M. Born and E. Wolf, Principe of optics, Chapter 1. Beijing: Science Press of China, 1981. [8] D. C. Dini, J. B. Rosolem, and J. E. Urso, Active wavelength converter for use with an optical timedomain reflectometer (OTDR) and method for increasing OTDR supervision distance range, US Patent 7369219 B2, May 6, 2008. [9] H. H. Lee, Y. H. Nam, D. Lee, H. S. Chung, and K. Kim, Demonstration of a low-cost 1625-nm OTDR monitoring for 350-km WDM networks with semiconductor optical amplifiers, IEEE Photonics Technology Letters, 2005, 17(4): 852 854. [10] Z. Zhang, Recent progress in distributed optical fiber Raman photon sensors at China Jiliang university, Photonic Sensors, 2012, 2(2): 127 147.