Non-Programmable Digital Thermostat

Similar documents
Owner s Manual Use with most Heat Pump systems: 1-Heat, 1-Cool 2-Heat, 1-Cool

OWNER'S MANUAL T0140. Contents Page #

5+2 DAY. Digital Thermostat. residential. & 1-cool. up to 2-heat PROGRAMMABLE THERMOSTAT. Venstar Inc. 05/08

Installation Instructions

Programmable 5-2 Day Digital Thermostat

Owner s Manual. Digital Thermostat. Non-Programmable

Owner s Manual. Digital. Heat Pump. 5+2 Day Programmable. Model S1-THEH21P5S HVAC SERVICE PARTS TM

Owner s Manual. Digital Thermostat

Programmable 5-2 Day Digital Thermostat

HEAT COOL 5+2 DAY PROGRAMMABLE 1-STAGE HEAT, 1-STAGE COOL. Installation Instructions TSTATCCPQ501 TSTATBBPQ501 P Digital Thermostat I2:00

5+2 DAY PROGRAMMABLE DIGITAL THERMOSTAT

5+2 DAY. OWNER S MANUAL Venstar Inc. 05/08

2 - Wire Programmable Digital Thermostat

Thermostat Remote Control & Receiver

5+2 DAY INSTALLATION. Digital Thermostat. residential. & 1-cool. up to. 1-heat PROGRAMMABLE HEAT COOL HEAT PUMP THERMOSTAT. Venstar Inc.

Carrier NON-PROGRAMMABLE DIGITAL THERMOSTAT. Dual Setpoint Thermoglow Backlight No Batteries Required Auto Changeover Locking Keypad

Humidity Module OWNER S MANUAL. Complete Control from

Owner s Manual. Digital Thermostat. Heat/Cool & Heat Pump 7-Day Programmable S1-THEM22P7S COMMERCIAL. Model HVAC SERVICE PARTS

MODEL TSTATBBPB101 PROGRAMMABLE DIGITAL THERMOSTAT. Heat Pump & Heat Cool. Meets California Title 24 Residential USERS INFORMATION MANUAL

5+2 Day. up to HEAT COOL

1 For All Programmable or Non-Programmable. Digital Thermostat. Meets Residential California Title 24

7-Day. Digital Thermostat. residential. & 2-cool

Owner s Manual. Digital Thermostat. Heat/Cool & Heat Pump 7-Day Programmable S1-THEU22P7S RESIDENTIAL. Model HVAC SERVICE PARTS

VENSTAR T1070 FAN COIL THERMOSTAT PROGRAMMABLE 2 OR 4 PIPE SYSTEMS OWNER S MANUAL AND INSTALLATION INSTRUCTIONS

Programmable Digital Thermostat

I2:00 Mo MODEL TSTATBBPB501 PROGRAMMABLE DIGITAL THERMOSTAT. Heat Pump & Heat Cool. Meets California Title 24 Residential USERS INFORMATION MANUAL

1 For All Programmable Digital Thermostat. Meets Residential California Title 24

1 For All Programmable Digital Thermostat

VENSTAR T1075 FAN COIL THERMOSTAT 7 DAY PROGRAMMABLE 2 OR 4 PIPE SYSTEMS OWNER S MANUAL AND INSTALLATION INSTRUCTIONS

Installation Instructions

Installation Instructions

Legacy Non-Programmable Owner s Manual

Installation Instructions

Small Digital Thermostat Controller Temperature Control

TC --- NHP, TC --- NAC Comfort Series Non---Programmable Thermostat. Owner s Manual

Owner s Manual. 5+2 Day Programmable Digital Thermostat

Programmable Digital Thermostat

Performance Non-Programmable Owner s Manual

User s Information Manual

5+2 Day. up to HEAT COOL

MULTI HEAT PUMP PANEL CASSETTE TYPE DUCTLESS INVERTER INDOOR UNIT OWNER'S MANUAL. Models: CH12CC230VI CH18CC230VI CH24CC230VI

user s information manual

Performance Non-Programmable Owner's Manual

Installation Instructions

Installation Instructions HEAT COOL FAN POWER

Installation Instructions

INSTRUCTIONS! DO NOT DISCARD!

Installation, Start -Up, and Operating Instructions

Installation Instructions

CT500 Electronic Thermostat

INSTRUCTIONS! DO NOT DISCARD!

For Quick Set-Up go to Page 14

WARNING Important Safety Information

INSTALLATION INSTRUCTIONS

Installer Guide. WARNING Important Safety Information. 1 Specifications

Compatibility. Contents. Necessary Tools

CTS Series. Owner s Manual. Full Color Touch Screen Display. and Installation Instructions. High Resolution Digital Thermostat

INSTALLER S & OWNER S MANUAL

1 PREPARATION 2 THERMOSTAT MOUNTING DIMENSIONS. CT70A Heat Pump Thermostat. Your Honeywell Thermostat. Recycling Notice. Do-It-Yourself Models

Auto-Changeover: Cool Setpoint: Deadband: Differential: Heat Setpoint: Icon: Mode: Non-Programmable Thermostat: Programmable Thermostat:

INSTRUCTIONS! DO NOT DISCARD!

Quick Start & Setup Guide

HEAT HEAT HEAT COOL COOL

INSTALLATION INSTRUCTIONS Venstar Inc. 08/07

CT2700 An Electronic Round Programmable Thermostat

Thermostat Series. Installation Manual TSTBM-RRS--TW-A Revised 02-13

Optima ZigBee Thermostat

Operation Manual. An investment of a small amount of time to review this manual will ensure proper performance of your Coal-Trol Digital system.

VX SERIES Wireless Thermostat with Occupancy Sensor

INSTRUCTION MANUAL P Heating and 1 Cooling

NON- INSTALLATION INSTRUCTIONS Venstar Inc. 08/07. Digital Thermostat T2700. commercial. & 2-cool. up to 2-heat PROGRAMMABLE

WARNING Important Safety Information

Residential Duct Mount Builder s Box Media Air Cleaner

Heating/Cooling Thermostat and Subbase Package T8196A/Q682A

DIGITAL THERMOSTAT. I2:00 Su AUTO OPTIONAL HUMIDITY MODULE

7-Day. Digital Thermostat. residential. & 2-cool

ITEM # BUILDER S SERIES CEILING FAN MODEL #41391

ARMITAGE CEILING FAN ITEM # MODEL #CC52WW5L. Español p. 17 ATTACH YOUR RECEIPT HERE. Purchase Date

WARNING Important Safety Information

Sentry LIQUID LEVEL CONTROLLER MODEL 120 OPERATING MANUAL.

WMWLB / WMWFM / WTWLB / WTWFM Series Hydronic Heating Unit

48 TAYLOR CEILING FAN

T2 -PHP, T2 -PAC Legacyt Series Programmable Thermostat. Owner s Manual

ITEM # , , PAWTUCKET CEILING FAN MODEL #40958, 40959, 40047

Installer Guide. WARNING Important Safety Information. 1 Specifications

INSTALLATION & OPERATION MANUAL

52 CEILING FAN. Owner s Manual Models #50336, 50337

Installation Instructions

Home and Building Control Home and Building Control Helping You Control Your World

MAYFIELD CEILING FAN LISTED E ITEM # MODEL #BTH44ABZC5C BTH44BNK5C Español p. 20 ATTACH YOUR RECEIPT HERE.

TILGHMAN CEILING FAN. LISTED For Damp Location E ITEM # MODEL #WCK52LMW5N WCK52NWZ5N. Español p. 20 ATTACH YOUR RECEIPT HERE

ITEM # HYDRA CEILING FAN MODEL #41371

INSTALLER S & OWNER S MANUAL

INSTRUCTION MANUAL P Heating and 2 Cooling with Humidification and De-humdification

ELECTRONIC COMMUNICATING THERMOSTAT : P COOL AUTO. Owner's Manual

ITEM # SAIL STREAM CEILING FAN MODEL #41695

Universal Fan and Light Remote Control

WARNING Important Safety Information

RK-05 Combustible Gas Transmitter Operator s Manual

RK CO 2 Transmitter Operator s Manual

Transcription:

OWNER'S MANUAL MODEL P474-0140 Non-Programmable Digital Thermostat HEAT PUMP THERMOSTAT 2 HEAT, 1 COOL emergency aux. heat normal energy save Fan On Fan Auto Millivolt Compatible Battery or System Powered Digital Display DC Voltage Compatible Stages: 2-Heat, 1-Cool Easy Operation Star Replacement Components Division - Carrier Corporation

OWNER'S MANUAL MODEL P474-0140 Contents Page # Safety Warnings Front Panel Display Normal Operation Aux Heat Preparation Remove Old Thermostat Battery Replacement Wire Connections Test Operation Troubleshooting Warranty Page 2

OWNER'S MANUAL MODEL P474-0140 Safety Warnings CAUTION P/N P474-0140 Follow Installation Instructions carefully. DISCONNECT POWER TO THE HEATER - AIR CONDITIONER BEFORE REMOVING THE OLD THERMOSTAT AND INSTALLING THE NEW THERMOSTAT. Page 3 WARNING CAUTION The two AA alkaline batteries must be replaced at least once every 12 months to ensure proper operation. The Low Battery icon (fig. 1) will appear on the display when it is time to replace the batteries. If the thermostat is FIG. 1 connected to 24v power, the batteries should still be installed, but are not required. When is displayed the batteries must be replaced immediately. The manufacturer cannot be liable for improper operation of the thermostat if the batteries are not immediately replaced. Annual battery replacement is especially critical in locations subject to freezing temperatures. The thermostat will be unable to turn on the heating system if the batteries are exhausted. This device complies with Part 15 of the FCC rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Replacement Components Division Carrier Corporation 03/07

OWNER'S MANUAL DIGITAL MODEL THERMOSTAT P474-0140 Front Panel DISPLAY emergency aux. heat normal energy save AUX HEAT INDICATOR UP & DOWN BUTTONS MODE SWITCH Heat, Off or Cool Fan On Fan Auto FAN SWITCH On or Auto AUX HEAT SWITCH Emergency Normal Lockout Page 4

OWNER'S MANUAL DIGITAL MODEL THERMOSTAT P474-0140 Display SET TEMP 78 74 Current room temperature. If the UP or DOWN button is pressed the thermostat will show the Set Temp indicator. When Set Temp is displayed you may use the UP or DOWN button to adjust the desired room temperature. NOTE: After five seconds with no button presses the thermostat will revert back to show the current room temperature. Page 5 Page 5

OWNER'S MANUAL DIGITAL MODEL THERMOSTAT P474-0140 Normal Operation emergency aux. heat normal energy save UP & DOWN BUTTONS Fan On Fan Auto MODE SWITCH Heat, Off or Cool FAN SWITCH On or Auto Operation Select Heat or Cool with the Mode Switch. Normally leave the fan switched to Fan Auto. In Fan Auto, the fan will turn on only with a heat or cool demand. When Fan On is selected, the fan will run continuously. Adjust the desired set temperature with the UP and DOWN buttons. Page 6

OWNER'S MANUAL MODEL P474-0140 Aux Heat emergency aux. heat normal energy save Fan On Fan Auto Aux Heat Indicator - This LED will illuminate when the thermostat has energized Aux Heat.* (W2 terminal) *The LED will only turn on when the thermostat is powered from the HVAC System. The cost of operating Electric Strip Heat (Aux Heat) is normally significantly more expensive than the cost of operating Heat Pump. Operation Switch AUX HEAT SWITCH Emergency Normal Energy Save Emergency - Disables all compressor functions** and energizes only Aux Heat to satisfy the heat demand. Normal - Aux Heat is allowed to run, if necessary, along with the heat pump to satisfy the heat demand. Energy Save - Aux Heat will never turn on regardless of the heat demand. ** When the Aux Heat Switch is in the Emergency position the compressor will also be locked out during cooling operation. Page 7

OWNER'S MANUAL MODEL P474-0140 Step #1 Preparation Preparation Proper installation of the thermostat will be accomplished by following these step by step instructions. If you are unsure about any of these steps, call a qualified technician for assistance. These tools will be required: Flat Blade Screwdriver Wire cutter & Stripper Make sure your Heat Pump is working properly before beginning installation of the thermostat. Carefully unpack the thermostat. Save the screws and instructions. Turn off the power to the Heat Pump at the main fuse panel. Page 8

OWNER'S MANUAL MODEL P474-0140 Remove & Replace Old Thermostat Remove the cover of the old thermostat. If it does not come off easily check for screws. Loosen the screws holding the thermostat base or subbase to the wall, and lift away. Disconnect the wires from the old thermostat. Tape the ends of the wires as you disconnect them, and mark them with the letter of the terminal for easy reconnection to the new thermostat. Keep the old thermostat for reference purposes, until your new thermostat is functioning properly. Page 9

OWNER'S MANUAL MODEL P474-0140 Battery Replacement The top of the thermostat housing has two screwdriver slots to assist in separating the thermostat front from the sub-base. SCREWDRIVER SLOTS To pull the housing apart, insert a small blade screwdriver into the slot and rotate 90. This will release the top housing snaps. Repeat this procedure in the other screw driver slot. Separate the thermostat front from the sub-base by pulling the top forward until the pins release, and then lift the bottom out. Next Page The batteries must be replaced immediately when the thermostat displays the low battery icon (fig.1). FIG. 1 Page 10

OWNER'S MANUAL MODEL P474-0140 Battery Replacement Remove the old batteries and replace with new AA alkaline batteries at least once every year or when the low battery icon appears (pages 3 and 10). POSITION BATTERIES AS SHOWN USE AA SIZE ALKALINE BATTERIES USE AA SIZE ALKALINE BATTERIES If the thermostat is connected to 24v power, the batteries should still be installed. Page 11

4Z95 OWNER'S MANUAL MODEL P474-0140 Wire Connections If the terminal designations on your old thermostat do not match those on the new thermostat, refer to the chart below or the wiring diagrams that follow. Wire from the old thermostat terminal marked Function Install on the new thermostat connector marked C Common C (optional) W1, W or H Auxiliary Heat W2 Y1 or Y Cooling Y O Rev. Valve O (Energize to Cool) B Rev. Valve B (Energize to Heat) G or F Fan G Rc, R, M, Vr, A Power R Thermal Insulating Sheet A label is provided on the backplate that prevents drafts originating inside the wall from entering the thermostat. These drafts, left unchecked, may cause incorrect room temperature readings. Please do not remove this label from the thermostat. Insert the wires through the slots provided in the label as shown in Fig. 1 Wire Slots Page 12 C W2 Y B O G R MODEL: P474-0140 97061606 USE SIZE AA ALKALINE BATTERIES MADE IN CHINA Fig. 1

OWNER'S MANUAL MODEL P474-0140 Sample Wiring Diagrams 5 Wire, 1 Stage Cooling, 2 Stage Heat, Heat Pump with O reversing valve. Residential Heat Pumps, split systems & package units, with auxiliary heat. Common wire optional* C W2 Y B O G R 5 Conductor 18 to 22 gauge unshielded cable from the thermostat to the equipment. POWER FAN REVERSING VALVE COMPRESSOR Y O G R ELECTRIC HEAT W2 * Common wire is optional in all installations. If a common wire is not used the thermostat must be powered by two AA alkaline batteries. These batteries must be replaced (page 10) each year or when the Low Battery indicator is displayed (page 3). Page 13

OWNER'S MANUAL MODEL P474-0140 Sample Wiring Diagrams 4 Wire, 1 Stage Cooling, 1 Stage Heat, Heat Pump with O reversing valve. Residential Heat Pumps, split systems & package units, with no auxiliary heat. Common wire optional* C W2 Y B O G R 4 Conductor 18 to 22 gauge unshielded cable from the thermostat to the equipment. POWER FAN REVERSING VALVE COMPRESSOR Y O G R * Common wire is optional in all installations. If a common wire is not used the thermostat must be powered by two AA alkaline batteries. These batteries must be replaced (page 10) each year or when the Low Battery indicator is displayed (page 3). Page 14

OWNER'S MANUAL MODEL P474-0140 Sample Wiring Diagrams 4 Wire, 1 Stage Cooling, 1 Stage Heat, Heat Pump with B reversing valve. Residential Heat Pumps, split systems & package units, with no auxiliary heat. Common wire optional* C W2 Y B O G R 4 Conductor 18 to 22 gauge unshielded cable from the thermostat to the equipment. POWER FAN REVERSING VALVE COMPRESSOR Y B G R * Common wire is optional in all installations. If a common wire is not used the thermostat must be powered by two AA alkaline batteries. These batteries must be replaced (page 10) each year or when the Low Battery indicator is displayed (page 3). Page 15

OWNER'S MANUAL MODEL P474-0140 Sample Wiring Diagrams 5 Wire, 1 Stage Cooling, 2 Stage Heat, Heat Pump with B reversing valve. Residential Heat Pumps, split systems & package units, with auxiliary heat. Common wire optional* C W2 Y B O G R 5 Conductor 18 to 22 gauge unshielded cable from the thermostat to the equipment. POWER FAN REVERSING VALVE COMPRESSOR Y B G R ELECTRIC HEAT W2 * Common wire is optional in all installations. If a common wire is not used the thermostat must be powered by two AA alkaline batteries. These batteries must be replaced (page 10) each year or when the Low Battery indicator is displayed (page 3). Page 16

OWNER'S MANUAL MODEL P474-0140 Test Operation Turn on the power to the Heat Pump. On the thermostat, slide the Mode Switch to HEAT. Press the UP or DOWN button until the set temperature is 10 degrees above room temperature. The HVAC unit should energize in the heating mode. Note: You may need to wait up to five minutes for heating to energize due to the compressor lockout feature. There is a two minute minimum run-time for first stage heating. On the thermostat, slide the Aux Heat Switch to the NORMAL position. If the thermostat is system powered the Aux Heat indicator will illuminate indicating that the thermostat has energized Aux Heat (page 7). TWO STAGE OPERATION - The 2nd stage of heat (auxiliary heat) is turned on when the room temperature is equal to or less than: the setpoint minus the 1st stage deadband (one degree, non-adjustable), minus the 2nd stage deadband (two degrees, non-adjustable). Heating Deadband Deadband db 2 (non-adj. 2 ) Cooling Deadband db 1 db 1 (non-adj. 1 ) (non-adj. 1 ) 2nd Stage turn on 1st Stage turn on Page 17 Heat or Cool Setpoint 1st Stage turn on

OWNER'S MANUAL MODEL P474-0140 Test Operation On the thermostat, slide the Mode Switch to COOL. Press the UP or DOWN button until the set temperature is 10 degrees below room temperature. The HVAC unit should energize in the cooling mode (Page 6). Note: You may need to wait up to five minutes for cooling to energize due to the compressor lockout feature. On the thermostat, slide the Mode Switch to OFF, then slide the Fan Switch to Fan On. The fan should turn on and run continuously (Page 6). Page 18

OWNER'S MANUAL MODEL P474-0140 TroubleShooting SYMPTOM: The slide switches on the thermostat are very difficult to move. CAUSE: The backplate of the thermostat is screwed too tightly into a wall that is not perfectly flat. REMEDY: Loosen the screws holding the thermostat into the wall. SYMPTOM: The Air Conditioning does not attempt to turn on. CAUSE: The cooling setpoint is set too high, the Mode Switch is not set for Cool, the batteries are too weak, or the Aux. Heat Switch is set for Emergency. REMEDY: Consult the Normal Operation section in this manual to: Lower the cooling setpoint (Page 6) Correct the Mode Switch position (Page 6) Replace the batteries (Page 10) Adjust the Aux Switch to Normal (page 7) SYMPTOM: The fan does not turn on even though the compressor has energized. CAUSE: The Fan Switch is not completely in the On or Auto position. REMEDY: Slide the Fan Switch firmly into the On or Auto position. Page 19

OWNER'S MANUAL MODEL P474-0140 TroubleShooting SYMPTOM: Aux Heat does not turn on. CAUSE: The Aux Heat Switch is set for Lockout. REMEDY: Consult the Aux Heat section of this manual to slide the Aux Heat Switch to Normal (Page 7). SYMPTOM: The Heating does not attempt to turn on. CAUSE: The heating setpoint is set too high, the Mode Switch is not set for Heat, the batteries are too weak, or the Aux Heat Switch is set for Emergency. REMEDY: Consult the Normal Operation section in this manual to: Raise the heating setpoint (Page 6) Correct the Mode Switch position (Page 6) Replace the batteries (Page 11) Adjust the Aux Switch to Normal (Page 7) 4Z95 Battery Stat P/N P474-0140 FCc Tested to Comply with FCC Standards FOR HOME OR OFFICE USE Page 20 P/N 88-419 Rev. 2

OWNER'S MANUAL MODEL P474-0140 Warranty Five-Year Warranty - This Product is warranted to be free from defects in material and workmanship. If it appears within five year from the date of original installation, whether or not actual use begins on that date, that the product does not meet this warranty, a new or remanufactured part, at the manufacturer s sole option to replace any defective part, will be provided without charge for the part itself provided the defective part is returned to the distributor through a qualified servicing dealer. THIS WARRANTY DOES NOT INCLUDE LABOR OR OTHER COSTS incurred for diagnosing, repairing, removing, installing, shipping, servicing or handling of either defective parts or replacement parts. Such costs may be covered by a separate warranty provided by the installer. THIS WARRANTY APPLIES ONLY TO PRODUCTS IN THEIR ORIGINAL INSTALLATION LOCATION AND BECOMES VOID UPON REINSTALLATION. LIMITATIONS OF WARRANTIES ALL IMPLIED WARRANTIES (INCLUDING IMPLIED WARRANTIES OF FITNESS FOR A PARTICULAR PURPOSE AND MERCHANTABILITY) ARE HEREBY LIMITED IN DURATION TO THE PERIOD FOR WHICH THE LIMITED WARRANTY IS GIVEN. SOME STATES DO NOT ALLOW LIMITATIONS ON HOW LONG AN IMPLIED WARRANTY LASTS, SO THE ABOVE MAY NOT APPLY TO YOU. THE EXPRESSED WARRANTIES MADE IN THIS WARRANTY ARE EXCLUSIVE AND MAY NOT BE ALTERED, ENLARGED, OR CHANGED BY ANY DISTRIBUTOR, DEALER, OR OTHER PERSON WHATSOEVER. ALL WORK UNDER THE TERMS OF THIS WARRANTY SHALL BE PERFORMED DURING NORMAL WORKING HOURS. ALL REPLACEMENT PARTS, WHETHER NEW OR REMANUFACTURED, ASSUME AS THEIR WARRANTY PERIOD ONLY THE REMAINING TIME PERIOD OF THIS WARRANTY. THE MANUFACTURER WILL NOT BE RESPONSIBLE FOR: 1. Normal maintenance as outlined in the installation and servicing instructions or owner s manual, including filter cleaning and/or replacement and lubrication. 2. Damage or repairs required as a consequence of faulty installation, misapplication, abuse, improper servicing, unauthorized alteration or improper operation. 3. Failure to start due to voltage conditions, blown fuses, open circuit breakers or other damages due to the inadequacy or interruption of electrical service. 4. Damage as a result of floods, winds, fires, lightning, accidents, corrosive environments or other conditions beyond the control of the Manufacturer. 5. Parts not supplied or designated by the Manufacturer, or damages resulting from their use. 6. Manufacturer products installed outside the continental U.S.A., Alaska, Hawaii, and Canada. 7. Electricity or fuel costs or increases in electricity or fuel costs for any reason whatsoever including additional or unusual use of supplemental electric heat. 8. ANY SPECIAL INDIRECT OR CONSEQUENTIAL PROPERTY OR COMMERCIAL DAMAGE OF ANY NATURE WHATSOEVER. Some states do not allow the exclusion of incidental or consequential damages, so the above may not apply to you. This warranty gives you specific legal rights and you may also have other rights which may vary from state to state. Page 21