SUPREMATouch Modular Fire & Gas Detection System

Similar documents
SUPREMATouch. Modular Fire & Gas Detection System

SUPREMATouch. Modular Fire & Gas Detection System

Touchpoint Pro Flexible Gas Control System

APPLICATION DATA SHEET

THE ULTIMATE SOLUTION FOR GAS DETECTION SYSTEMS. DRÄGER REGARD

PrimaX IR Gas Transmitter Designed for Reliable Performance in Extreme Conditions

IGD.CO.UK

APPLICATION DATA SHEET

MSA Fixed Gas & Flame Detection for the Automotive Industry

Products and performance

S5000 Gas Monitor. GMS5000.com

Touchpoint Plus. A whole new control experience

Industrial Grade Gas Detection Detecting The Difference

Dräger Polytron 7000 Fixed gas detector

GasGard 100 Control System

Detectors-Transmitters for Flammable, Toxic Gases and Oxygen. Non-intrusive operation via intrinsically safe infrared remote control.

P R O D U C T D ATA S H E E T

MODEL 9010/9020 LCD CONTROL UNIT

P R O D U C T D ATA S H E E T

Dräger Polytron 8200 CAT Detection of flammable gases and vapors

RAYCHEM NGC-30 COMPONENTS

Dräger Polytron 8000 Stationary gas detector (EC)

MX43. Analog and digital controller. 4 or 8 lines / 16 to 32 detectors max. Highly versatile controller. SIL1 reliability. Gas Detection Control Panel

ULTIMA X5000. MSAX5000.com

IR4000. Point Infrared Combustible Gas Detection System. The Reliable and Flexible Safety Solution That s Low Maintenance

Model D12-IR. Digital Gas Transmitter...

Gas Controller Module GC-06

System 57. An advanced World of intelligent gas detection system management

MX43. Analog and digital controller. 4 or 8 lines / 16 to 32 detectors max. Highly versatile controller. Cost savings on wiring installation

Fixed Gas & Flame Detection International Product Range Overview

Process Alarm Solutions

P R O D U C T D ATA S H E E T

Dependable Solutions for Gas Detection

Fixed Range. Fixed Gas Detection Equipment. Field mounted gas detection. solutions for the protection of. plant and personnel

For Complete Fire and Gas Solutions

NGC-40 PANEL MOUNTED ADVANCED MODULAR HEAT-TRACING CONTROL SYSTEM HTC HTC3

Fire and Gas Monitoring Panel ST7-HV

Danfoss gas detection unit Type GD Heavy Duty

Gas Detection. Touchpoint Plus. A whole new control experience

SCC Inc. Master Panel. Specifications. Document No. TS 2010 February 11, Product Description. Sample Specification

Industrial Grade Gas Detection

Dräger Polytron 5200 CAT Detection of flammable gases and vapours

Advanced FireAlarm Panel 1-4Loop

Dräger Polytron 8310 IR Detection of flammable gases and vapour

NGC-40 PANEL MOUNTED ADVANCED MODULAR HEAT-TRACING CONTROL SYSTEM HTC HTC3 PRODUCT OVERVIEW

System 57. An advanced world of intelligent gas detection system management

P R O D U C T D ATA S H E E T

Master devices. Type X-AIR-ZMAS. Zone master module for up to 25 zone modules, with integral webserver and interfaces to higher-level systems

YOUR PARTNER IN FIRE & GAS DETECTION

Intelligent addressable fire alarm control panel

FUNCTIONAL SAFETY MANUAL. Gassonic Observer-H and Observer-i Ultrasonic Gas Leak Detector

PANEL MOUNTED ELECTRONIC MULTI-CIRCUIT HEAT-TRACING CONTROL, MONITORING AND POWER DISTRIBUTION SYSTEM mm. 100 mm

Analog and digital controller. 4 or 8 lines / 16 to 32 detectors max. Highly versatile controller. Cost savings on wiring installation

4-20mA CYBER Cyber Transmitter for flammable, toxic and IR gas detection Cyber Head Increased security in ATEX certified head

P R O D U C T D ATA S H E E T

FUNCTIONAL SAFETY MANUAL

MSA Flame and Gas Detection. [ for the Oil, Gas and Petrochemical Industries ]

Danfoss gas detection units

P R O D U C T D ATA S H E E T

Toxic Gas Detection. Model F12. Toxic Gas Detection

Dräger Polytron 8700 IR Detection of flammable gases and vapors

Dräger REGARD 3900 Series Control System

IQ8Control C Fire Alarm Panel

SAFETY MANUAL. Intelligent Sensors for H 2 S Gas Applications

ZXSe Range Data Sheet

Dräger Polytron 8100 EC Detection of toxic gases and vapors

Multi-Gas-Controller MGC2

Dräger Polytron 8100 EC Detection of toxic gases and oxygen

Touchpoint Plus. A whole new control experience

Detection, Protection, Innovation

5New features & EXtreme design, now with HART Protocol and DuraSource Technology. Ultima X Series Gas Monitors

ZXe INTELLIGENT MULTI PROTOCOL FIRE ALARM CONTROL PANEL

Entwicklung + Fertigung + Service: Heerweg 15 D, Denkendorf Tel.: / Fax.: /

SIL 2. Ultima X Series Gas Monitors CERTIFIED

ZXSe Range. Fire Safety. Analogue addressable fire alarm control panel KEY FEATURES. Panel Features

configurable safety and programmable logic SLATE Integrated Combustion Equipment Management The revolutionary integration of

System Overview F300K Compact Flame Scanner. Sensors and systems for combustion engineering.

The ID51 & ID52 can be upgraded to 2 loops without the need to change back box. FEATURES. Intelligent Features

HOW TO SPECIFY A DELPHIAN SYSTEM

EMS510 PS-1 COMPLIANT OPACITY/DUST MONITOR

P R O D U C T S P E C I F I C A T I O N MSA Ultima X Series Sensor/Transmitter Specification

Industrial Grade Gas Detection

Danfoss gas detection units

SAFETY CERTIFIED MODEL FP-700 COMBUSTIBLE GAS DETECTOR

Dräger Polytron Pulsar 2 Detection of flammable gases and vapours

designed for rail 5000 Series

Solution F2. Fire Alarm Control Panels one step ahead.

3M Oldham MX 43 Controller

Dräger Polytron 8310 Stationary gas detector (DSIR)

Bionics Instrument. Alarm Handling. Gas Alarm Systems

Solution F1. Fire Control Panels the new generation

APPLICATION DATA SHEET

TYPE CM-2201 NELSON SINGLE POINT CIRCUIT MANAGEMENT SYSTEM

Dräger Polytron 8700 IR Detection of flammable gases and vapors

On the job around the clock 24/7: Fire detection systems

Two-Channel Gas Controller

Dräger REGARD -1 Control System

Dew point set DS 400

Recalibrate the way you look at gas detection

The Next Generation Machine Protection System

Transcription:

SUPREMATouch Modular Fire & Gas Detection System Because every life has a purpose

Class Leading Fire & Gas Detection Solutions MSA s permanent gas detection systems are relied upon by a huge number of installations across a wide range of industries throughout the world to protect employees, facilities and our environment from fire and hazardous gases. As a highly experienced designer and manufacturer of gas and flame detection equipment, MSA provides the optimum combination of detectors, field devices, components and systems that will ensure reliable and secure protection of personnel and facilities.suprematouch can be used with a wide range of detectors including flammable and toxic gas, oxygen, smoke, fire and heat and manual call points. A range of outputs are provided, including relay and analogue, while interfacing to external systems is provided using Modbus or Profibus. Remote racks can be connected using digital communication. Designed around standard industrial 19 racks, SUPREMATouch provides signal processing for up to 256 sensor inputs and 512 relay outputs. It can be configured to meet the requirements of even the most demanding of applications, including redundant systems up to SIL3 and complies with all relevant global safety standards. New Enhancements offer a Lower Cost of Ownership The SUPREMATouch s new features will not only reduce your total cost of ownership, but it now comes close to functionalities of many PLCs, due to addition of logic functions. This enhanced controller is still compatible with current SUPREMATouch installations and is certified to all relevant standards in the field of fire and gas hazard detection (ATEX, SIL3, CSA, ccsaus, CCCF, TPTC). Enhancements to the SUPREMATouch include: New Analog input module MAI30 reduces system complexity Unique input module for all sensor types with automatic detection No additional sensor specific plug-in modules necessary anymore Optional HART support Extension of switching logic with time delays and multi-level logic New Hardware Dedicated switch inputs for acknowledge and reset of points and groups USB & Ethernet New more efficient power supply Improved user interface with modern intuitive tiles Additional Calibration options One-man-calibration Group calibration Remote calibration of HART transmitters Integrated Webserver and network time synchronization Micro SD Card support for data logging and backups Enhanced SUPREMA Manager software Administrating several SUPREMA systems incl. reporting Offline configuration and parametrization Significantly more comfortable parametrization Compatible with MSA s complete range of gas and fire detectors System configuration can be intuitively executed via touchscreen. The user friendly touch screen makes any operation of the SUPREMATouch simple. The status signals of up to 256 sensors can be linked and grouped by selecting a checkbox with a simple touch of the display No programming skills are necessary. MSAsafety.com

System Flexibility from Modular Design MODULES MDO Display & Operation MCP Central Processing MAI Analog Input MAR Analog input Redundancy MGI General Input MGR General input Redundancy MAO Analog Output MGO General Output MAT Analog Terminal MRC Relay Connec!on MRO Relay Output SUPREMATouch Field devices Switches Analog Outputs Relay Outputs MAT MAT MAT MRO MRC MAR MGR MCP 1 MCP 2 MAI MGI MAO MGO MGO 1 2 CAN Bridge CAN Bridge CAN A CAN B non-redundant system redundant system optional modules 24V DC Gateway Gateway MDO USB 115/230V AC Ethernet Battery RS232 Only seven basic modules are necessary to provide full functionality, namely MCP20, MDO20, MAI30, MGO20, MGI30, MAO20 and gateways. Due to its proven modular design, SUPREMATouch easily fits most installations and has the ability to be expanded with the requirements of the plant. This concept ensures the maximum protection of people and plant with minimal additional outlay.

New Calibration Features One man Calibration Simplifies calibration procedure by automatically transferring the gas values conforms to ATEX guidelines. Response time is measured (in accordance with ATEX) Direct lower total cost of ownership Remote Calibration The HART support offers the ability to calibrate MSA detectors at hard to reach areas or those without a control interface Ideal for hard to access areas No additional tools for calibration necessary The HART option on a gas detection controller system is outstanding in its class. Group Calibration It is now possible to calibrate several compatible measuring points at the same time. Up to 32 measuring points per group Saves time and money MSAsafety.com

SUPREMATouch Software SUPREMA Manager MSA s SUPREMA Manager software is available for a USB connected PC which is especially useful during commissioning and regular sensor calibration of larger systems. This provides all the functions available at the SUPREMATouch display such as configuration and calibration, offline use and the storing and printing of reports as PDF documents. Highlights: Supports new features of SUPREMATouch More comfortable on parametrization, diagnosis, calibration and maintenance System reports on documentation Graphic visulisation and modification of complex new multi-level relay logic is shown as tree-view This provides a user friendly environment for configuration (screen view shown), parameter setting and sensor calibration of large systems to minimise the cost of maintaining SUPREMATouch. SUPREMA Calibration Software In addition to the SUPREMA Manager, MSA offers dedicated Calibration software, which is able to calibrate passive sensors, supporting standard calibration and zero adjustment for transmitters. Its main advantage, however, is that it provides the option to issue detailed calibration reports whilst based on user defined criteria.

Technical Specifications Enclosure System Detailed ordering information available upon request. Standard 19 rack 3U high (up to 8 racks per system) Satellites for decentralised input and outputs up to a distance of 5000 m Optional redundant configuration Event and fault diagnosis logging Inputs Up to 256 sensor inputs and 64 switch inputs per system Up to 80 inputs per rack Outputs Up to 512 relay outputs and 256 analogue outputs per system Up to 400 outputs per rack Switched open-collector driver (24 V, 300 ma) Relays SPCO or SPST redundant (230 V, up to 5A) Optional solid state relays for low current applications Software-control of switched outputs/relays Creation of groups n out of m alarms Multi-level logic Time delays Alarm multiplication Power supply Operating voltage range 18 to 32 VDC Optional rack power supply 85 to 265 VAC, 250 W, 50/60 Hz Power supply connections for internal, external and battery backup (24 VDC) with automatic switch-over Display Colour LCD touch screen with backlight 5.7 TFT with 320 x 240 resolution Controls and Alarm reset and acknowledge keys indicators Switch inputs for remote reset and acknowledge Front panel LEDs for alarms 1, 2, 3 and 4, signal fail, inhibit, power and system fail 3 level password or keyswitch for secure access control Detectors Catalytic or IR for combustible 4 20 ma transmitters, transmitters with HART ability Electrochemical for toxic and oxygen Conventional smoke, heat and fire detectors Approvals ATEX (EN 50104:2010, EN 50271:2010, EN 60079-29-1:2007; EN 50270:2015); Dekra-EXAM; EN 61010:2011 ccsaus (CSA) SIL 3 (EN 50402:2005+A1:2008, EN 61508:2010); TÜV CCCF (GB16808-2008) TP TC 020/2011, TP TC 004/2011 Interfaces Optional interfaces to external bus systems (Modbus RTU and TCP, Profibus) 2 x RS-232 and 1 x USB electrically isolated interfaces for data transfer Ethernet, microsd card Printer report of system events (standard ASCII, 80 CHR) PC Software SUPREMA Manager SUPREMA Calibration Both ATEX approved and Win7&10 compatible Your direct contact Great Britain Hopton Park, Devizes Wiltshire, SN10 2JP United Kingdom Phone +44 (0)800 066 2222 info.gb@msasafety.com For contact details of your local MSA affiliate, please visit our website. Subject to change without notice ID 07-500.2 UK/13 MSAsafety.com